Fundamentals / Physics / Thermodynamics and statistical physics

Thermodynamics and statistical physics · Advanced study

Read the connected derivations and worked problems in sequence, or open each chapter in its home course.

  1. Reservoirs, useful work and mixtures

    Keep track of which reservoir fixes temperature, chemical potential or pressure. Close the energy and entropy balances before inferring the useful work or the coexisting phase fraction.

  2. Heat stored in quantum degrees of freedom

    Build the single-particle spectrum before taking the thermal average. Compare acoustic branches, magnetic ordering and paired electrons, and trace how a radiometer samples a photon reservoir.

  3. Irreversible heat transfer and fluctuating signals

    Measure a transport coefficient using a steady gradient and a decay. Derive the fluctuation that survives in equilibrium and work out which part of it a finite-bandwidth instrument measures.

  4. Ensembles, diffusion and finite data

    Contrast conservation along a microscopic orbit with apparent relaxation after coarse sampling. Test a diffusion law and infer an unknown thermal state from a sequence of noisy observations.

Reservoirs, useful work and mixtures

Keep track of which reservoir fixes temperature, chemical potential or pressure. Close the energy and entropy balances before inferring the useful work or the coexisting phase fraction.

  1. State, process and the first law for a closed system
  2. Open systems, enthalpy and steady-flow devices
  3. Entropy, irreversibility and useful-work loss
  4. Phase equilibrium and steam quality
  5. Gas mixtures, humidity and condensation
  6. Useful work and exergy destruction
  7. Why a real gas cools or warms across a throttle
  8. Finding the vapour fraction of an equilibrium flash
  9. When does a polar crystal change its preferred state?
  10. Moving constraints, boundary work and a changing energy

State, process and the first law for a closed system

Distinguish properties from path-dependent transfers and determine heat and work for a piston-cylinder process.

From first principles

Obtain closed-system work from the motion of a boundary

Choose a fixed mass of gas enclosed by a piston and cylinder. No mass crosses this boundary. The first law is the empirical balance of energy: with heat positive into the gas and work positive out, change of internal, kinetic and potential energy equals net heat minus net work. For a piston moving normally through \(dx\) against a uniform resisting pressure \(p_{\rm ext}\), force times displacement gives

\[\delta W_b=p_{\rm ext}A\,dx=p_{\rm ext}\,dV,\]
\[\Delta(U+KE+PE)=Q-W .\]

For slow internal equilibration with tiny pressure differences, one can use gas pressure in the integral. If bulk kinetic and potential changes are negligible and no shaft or electrical work crosses the boundary, the integrated heating requirement is

\[Q_{12}=U_2-U_1+\int_{V_1}^{V_2}p_{\rm ext}\,dV .\]

The area under the specified pressure–volume path is therefore part of the heat calculation. For a rigid vessel it vanishes. For a constant-pressure piston heating an ideal gas, \(p\Delta V=mR\Delta T\) adds to the internal-energy change. The end temperatures alone determine the ideal-gas internal-energy change, while the moving boundary determines the work.

Derivation and applications

Determine the heat input when a spring loads the piston

A freely sliding piston does not necessarily hold the gas pressure constant. Attach a linear spring to a frictionless piston of area \(A\) and let its resisting force increase as the gas expands. Consider a closed mass \(m\) of ideal gas, heated slowly enough that piston force balance holds at each intermediate state. Neglect piston kinetic energy, heat leakage and changes of elevation except as already included in the constant external pressure \(p_1\). At the initial position the gas is in equilibrium at absolute pressure \(p_1\) and volume \(V_1\).

The displacement \(x\) produces a volume increment \(Ax\) and an extra resisting force \(kx\). Dividing by piston area gives the pressure as a function of the evolving volume:

\[V-V_1=Ax,\]
\[p(V)=p_1+\frac{k}{A^2}(V-V_1).\]

Boundary work is performed at this changing external pressure. Integrating the straight-line path over the swept volume \(\Delta V=V_2-V_1\) separates work against the initial pressure from work stored in the spring:

\[W_{12}=\int_{V_1}^{V_2}p(V)\,dV=p_1\Delta V+\frac{k}{2A^2}(\Delta V)^2.\]

For constant specific heat \(c_v\) and specific gas constant \(R\), the first law gives the heat required, positive into the gas. State temperatures follow from the ideal-gas relation, including the final spring pressure:

\[Q_{12}=m c_v(T_2-T_1)+W_{12},\]
\[T_i=p_iV_i/(mR).\]

Only the temperature change determines the internal-energy change; the mechanical law selects the work term. Setting \(k=0\) recovers expansion against constant pressure. Abrupt heating that accelerates the piston would invalidate the assumed quasistatic pressure path.

Worked example

Calculate the heater input for an air cylinder

Take \(m=0.0100\) kg, \(V_1=0.0100\) m³, \(p_1=100\) kPa, \(A=0.0100\) m² and \(k=1000\) N/m. Increase volume by \(0.00200\) m³. The final pressure is \(120\) kPa; the work is

\[(100+120)(0.00200)/2=0.220\,\mathrm{kJ}.\]

For \(R=0.287\) and \(c_v=0.718\) kJ/(kg K), \(\Delta T=(1.440-1.000)/(0.0100\times0.287)=153\) K. The gas receives \(1.10+0.220=1.32\) kJ of heat.

Second application

Separate actuator work from stored spring energy

On the same stroke the piston travels \(0.200\) m. The initially unloaded incremental spring stores \(kx^2/2=20.0\) J, exactly the triangular part of the pressure–volume work. The constant load receives \(200\) J. If the spring were removed while retaining the same initial state and swept volume, the final pressure would stay at \(100\) kPa and the temperature rise would be only \(69.7\) K. The two processes end at different thermodynamic states despite having the same final volume.

Try it · Spring piston

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Decide what crosses the boundary

Draw a boundary around the gas in a piston cylinder. If no gas crosses its surface, the system is closed even though the piston moves. A rigid vessel is a special closed system with fixed volume. An insulated wall prevents heat transfer; a shaft or electrical lead can still transmit work through it. These descriptions impose different constraints and should be identified before choosing an equation.

At equilibrium a simple compressible substance can be described using independent state variables such as temperature and specific volume. Pressure \(p\), volume \(V\), temperature \(T\) and internal energy \(U\) are properties. An equation of state relates some of them. For a dilute ideal gas \(pV=mRT\), where \(R\) is the specific gas constant. Always use absolute pressure and absolute temperature in this relation. Two initial and final states determine changes in properties, but do not specify the heat and work transfers between them.

Construct the process energy balance

Take work done by the system as positive and heat entering it as positive. The first law is

\[\Delta U+\Delta KE+\Delta PE=Q-W.\]

For a stationary vessel ignore changes in kinetic and gravitational energy of the system as a whole. A moving piston of area \(A\) against external pressure \(p_{\rm ext}\) performs incremental work \(p_{\rm ext}A\,dx=p_{\rm ext}dV\). For a quasistatic mechanically reversible motion the boundary pressure can be represented by the gas pressure throughout the process.

If gas expands from \(V_1\) to \(V_2\) at constant external pressure,

\[W=p_{\rm ext}(V_2-V_1).\]

If it instead follows a reversible isothermal ideal-gas path, inserting \(p=mRT/V\) and integrating gives

\[W=mRT\ln(V_2/V_1).\]

Both expressions have units of energy. Their different volume dependence makes a pressure-volume diagram useful: the area under each pressure path has a direct work interpretation when its boundary-force assumptions hold.

Background · Which pressure enters the boundary-work integral?

The traction at a moving boundary determines the mechanical work across it. For a piston use the pressure exerted against the load. Replacing it by a uniform equilibrium gas pressure additionally assumes slow mechanical evolution. A limiting comparison makes this distinction measurable.

\[W_{\mathrm{by}}=\int_{V_1}^{V_2}p_{\mathrm{ext}}\,dV.\]

Remove a partition in an insulated rigid vessel so that an ideal gas expands into a vacuum. The external pressure against the advancing gas is zero. There is no heat transfer or boundary work, so the gas returns to the same equilibrium temperature. A reversible isothermal expansion between those same gas volumes requires heat from a bath and yields positive work \(nRT\ln(V_2/V_1)\). The two endpoint states alone do not define a work measurement.

Heat air below a freely moving piston

A weight-loaded, frictionless piston keeps 0.50 kg of ideal air at 150 kPa absolute as a heater raises its temperature from 300 to 360 K. Use constant properties \(R=0.287\) and \(c_v=0.718\) kJ/(kg K). The ideal-gas law gives the volumes at the two ends of the process.

\[\begin{aligned} V_1&=\frac{mRT_1}{p}=0.2870~\mathrm{m^3},\\ V_2&=\frac{mRT_2}{p}=0.3444~\mathrm{m^3}. \end{aligned}\]

The pressure is constant, so the work is the area of a rectangle on a pressure–volume diagram. Internal energy depends on the gas temperature. These are separate contributions to the heat input.

\[\begin{aligned} W&=p(V_2-V_1)=150(0.0574)~\mathrm{kJ}=8.61~\mathrm{kJ},\\ \Delta U&=mc_v(T_2-T_1)=0.50(0.718)(60)~\mathrm{kJ}\\ &=21.54~\mathrm{kJ}. \end{aligned}\]

The required heat is

\[Q=\Delta U+W=30.15\,\mathrm{kJ}.\]

The same result follows from \(mc_p\Delta T\) because for this constant-pressure ideal-gas process with only boundary work \(c_p=c_v+R=1.005\) kJ/(kg K). The extra heat above the internal-energy increase moved the piston weight. Using \(Q=mc_p\Delta T\) without inspecting the constraint would give the wrong heat input to a rigid tank.

Compare a rigid-wall experiment

Lock the piston at its initial volume before heating an identical mass from 300 to 360 K. Now \(W=0\), so only 21.54 kJ of heat is needed. The final pressure is

\[150(360/300)=180\,\mathrm{kPa}.\]

Equal temperature changes in an ideal gas imply equal changes in internal energy, even though final pressures and energy transfers differ. For a real fluid near a phase boundary, constant ideal-gas heat capacities may fail; use tabulated state properties or a suitable equation of state. In either case the first-law accounting is unchanged once the initial and final internal energies and the actual boundary work are known.

A different path between specified volumes

An ideal gas initially at 300 kPa and 0.020 m³ expands quasistatically and isothermally to twice its initial volume. Since \(pV=p_1V_1\), work out is

\[W=p_1V_1\ln(V_2/V_1)=6\ln2=4.16\,\mathrm{kJ}.\]

Ideal-gas internal energy depends only on temperature, so \(\Delta U=0\) and heat entering equals 4.16 kJ. A freely expanding ideal gas in an insulated rigid outer vessel can reach the same final temperature and occupied volume while doing zero boundary work. The state variables alone do not record which process occurred.

Determine heat and work along a measured compression path

A measured pressure–volume trace contains more information than its endpoints. For some slow piston processes an empirical polytropic law \(pV^n=\text{constant}\) fits the path. Here \(n\) is a fitted process exponent and need not equal the gas heat-capacity ratio. Assume a closed cylinder with negligible kinetic and potential energy change, a quasistatic pressure load and a calorically perfect ideal gas. Work out of the gas is the area \(W=\int_{V_1}^{V_2}p\,dV\), which is negative for compression. Substitute \(p=p_1V_1^n V^{-n}\) and integrate:

\[W=\frac{p_2V_2-p_1V_1}{1-n}\quad(n\ne1),\]
\[W=p_1V_1\ln(V_2/V_1)\quad(n=1).\]

The logarithmic case is the continuous limit as \(n\) approaches one. The ideal-gas equation also gives \(T_2/T_1=(V_1/V_2)^{n-1}\), so \(\Delta U=mc_v(T_2-T_1)\). With \(Q-W=\Delta U\) and \(pV=mRT\), the heat input is \(Q=m[c_v+R/(1-n)](T_2-T_1)\) for \(n\ne1\). Setting \(n=\gamma=c_p/c_v\) eliminates \(Q\). This inference relies on the ideal-gas, constant-property, quasistatic assumptions. An arbitrary irreversible compression with the same endpoints cannot be called isentropic from the fitted exponent alone.

Recover a cylinder heat loss from three measurements

A test traps air at \(p_1=100\,\mathrm{kPa}\) absolute, \(V_1=0.0100\,\mathrm{m^3}\), \(T_1=300\,\mathrm K\), then compresses it to \(V_2=0.0040\,\mathrm{m^3}\). The fitted exponent is 1.25. Using \(R=0.287,\ c_v=0.718\,\mathrm{kJ/(kg\,K)}\), the trapped mass is

\[p_1V_1/(RT_1)=0.01161\,\mathrm{kg}.\]

The predicted pressure is

\[100(2.5)^{1.25}=314.4\,\mathrm{kPa},\]
\[T_2=300(2.5)^{0.25}=377.2\,\mathrm K.\]

Note that absolute pressure is required in both the fit and the gas law. A pressure transducer referenced to atmosphere would need its reference restored.

The gas does \(W=[314.4(0.0040)-100(0.0100)]/(1-1.25)=-1.03\,\mathrm{kJ}\). Its internal energy rises by \(0.01161(0.718)(77.2)=0.644\,\mathrm{kJ}\), giving \(Q=\Delta U+W=-0.386\,\mathrm{kJ}\). Compression work enters the gas while part leaves as heat through the cylinder wall. If the process were isothermal at 300 K, the same volume change would require only \(-W=0.916\,\mathrm{kJ}\) and the full amount would leave as heat. A mid-stroke measurement gives a stronger check than the end pressure: the fitted law predicts \(100(0.010/0.007)^{1.25}=156.2\,\mathrm{kPa}\) at 7.0 litres. A substantial discrepancy would favour direct numerical integration of the measured trace over using a single exponent.

An apparent exponent can also be estimated directly from pressure ratios:

\[n=\ln(p_2/p_1)/\ln(V_1/V_2).\]

Compare estimates from the first and second halves of the stroke. Agreement means the same log–log slope describes both halves, while disagreement may indicate changing heat transfer, leakage or phase lag between the pressure and position sensors. It does not identify which of those mechanisms is responsible. As a separate check, suppose a water jacket gains the estimated 0.386 kJ each stroke and the compressor completes ten such strokes per minute. The mean heat removal from these strokes would be \(0.386(10)/60=0.0643\,\mathrm{kW}\). A jacket measurement of the complete machine includes intake and exhaust processes and mechanical friction as well, so experimental comparison requires either an isolated compression interval or a balance around the rest of the cycle.

A change in operating speed can also change the fitted exponent because it changes the time available for heat exchange during a single compression stroke.

Open systems, enthalpy and steady-flow devices

Use an inlet-outlet balance to distinguish shaft work, kinetic-energy conversion and pressure reduction.

From first principles

Derive the steady-flow energy balance including flow work

Surround a turbine, nozzle or mixing chamber with a stationary control surface. In addition to transporting its internal, kinetic and gravitational energies, an entering fluid is pushed across the inlet by upstream pressure. A mass increment \(dm\) occupies volume \(v\,dm\) and requires pressure work \(pv\,dm\) to enter. The outlet carries the corresponding work away. Combining internal energy \(u\) and flow work defines enthalpy:

\[h=u+pv,\]
\[e_{\rm stream}=h+V^2/2+gz .\]

Here \(V\) denotes speed, \(v\) specific volume and \(z\) elevation. In steady operation, sum these stream contributions and include heat into and shaft work out of the control volume. For one inlet and one outlet with equal mass rate, rearrangement gives

\[\dot Q-\dot W_s=\dot m\,[h_2-h_1+(V_2^2-V_1^2)/2+g(z_2-z_1)] .\]

All terms have units of power. A nozzle can accelerate flow without shaft work by lowering static enthalpy. A throttle with no heat, no shaft work and negligible speed and elevation changes is instead approximately isenthalpic. Omitting the pressure work while also using internal energy would miss both conclusions.

Background · Specific enthalpy
\[h=u+pv\]

Specific quantities are per unit mass. Enthalpy accounts for internal energy and flow work when mass passes through a control surface.

Derivation and applications

Convert a nozzle energy balance into a mass-flow limit

A steady nozzle converts static enthalpy into bulk kinetic energy. A converging passage has a maximum possible mass flow at a specified inlet stagnation state. Derive this for a steady, one-dimensional, adiabatic ideal gas with constant \(c_p\) and \(\gamma\), reversible acceleration and negligible inlet-reservoir velocity. Write reservoir conditions as \(T_0,p_0\) and the local static conditions as \(T,p\). With no shaft work the energy balance gives

\[c_pT_0=c_pT+u^2/2,\]
\[u=\sqrt{2c_pT_0(1-T/T_0)} .\]

Isentropic acceleration links temperature and pressure. Let \(r=T/T_0\), so \(p/p_0=r^{\gamma/(\gamma-1)}\). The mass flux is \(\rho u\) and ideal-gas density is \(p/(RT)\). Substitution gives a function of just one local variable:

\[G(r)=\frac{p_0}{RT_0}\sqrt{2c_pT_0}\,r^{1/(\gamma-1)}\sqrt{1-r}.\]

To find its maximum differentiate \(\ln G=(\ln r)/(\gamma-1)+\ln(1-r)/2+\text{constant}\). Equating the two derivative terms gives the sonic temperature and pressure ratios:

\[r_*=\frac{2}{\gamma+1},\]
\[p_*/p_0=\left(\frac{2}{\gamma+1}\right)^{\gamma/(\gamma-1)},\]
\[u_*^2=\gamma R T_* .\]

The flow through a converging exit is choked when downstream pressure is low enough for this state to be reached. Further lowering downstream pressure changes the flow after the exit; the ideal mass flux at that exit remains fixed. The model omits wall friction, heat transfer and discharge-coefficient corrections.

Worked example

Size a sonic air metering aperture

For \(p_0=200\) kPa absolute, \(T_0=300\) K, \(\gamma=1.40\) and \(R=287\) J/(kg K), the critical state has \(T_*=250\) K and \(p_*=105.7\) kPa. Then \(\rho_*=1.47\) kg/m³ and \(u_*=317\) m/s, giving \(G_*\simeq467\) kg/(m² s). A \(20.0\) mm² effective aperture meters about \(9.33\) g/s if the downstream pressure allows choking.

Second application

Decide whether a higher receiver pressure matters

Raise the receiver pressure to \(160\) kPa. Its ratio to reservoir pressure is now \(0.800\), above the critical \(0.528\). An ideal converging nozzle discharges at this pressure with \(r=0.800^{(0.4/1.4)}=0.938\). The energy equation gives \(u\approx193\) m/s, static density about \(1.98\) kg/m³, and mass flux about \(382\) kg/(m² s). Through the same aperture the predicted flow falls to \(7.64\) g/s. A model assuming choked flow at both settings would miss this change.

Try it · Nozzle

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Account for fluid entering and leaving

A closed-system piston can be followed with its gas. A continuously operating turbine has fresh fluid crossing its boundary every second. Enclose the hardware and its internal flow in a stationary control volume. Flowing mass carries internal energy \(u\), kinetic energy \(v^2/2\) and gravitational energy \(gz\) per kilogram. Upstream pressure also does work pushing fluid in, while downstream pressure opposes its exit. Per unit mass this flow work is \(p/\rho\), motivating the specific enthalpy \(h=u+p/\rho\).

Adding all incoming and outgoing energy rates gives, for one inlet, one outlet and constant stored energy,

\[\dot Q-\dot W_s=\dot m\left[h_2-h_1+(v_2^2-v_1^2)/2+g(z_2-z_1)\right].\]

Here \(\dot W_s\) is shaft power out of the control volume. Pressure work at the flowing boundaries is already contained in enthalpy; adding it once more would count it twice. One inlet and outlet have the same steady mass rate even when their volumetric flow rates differ dramatically because gas expands.

Read the dominant energy conversion

In a short, insulated nozzle there is no shaft, the elevation difference is small and falling enthalpy raises velocity. The property \(h+v^2/2\) is then constant, often called stagnation enthalpy. In an insulated turbine with small inlet and outlet speeds, the enthalpy drop instead appears mainly as positive shaft work. An insulated compressor takes work in, raising enthalpy. An insulated throttling valve has neither shaft power nor a large net change of bulk kinetic energy between distant ports, so its inlet and outlet enthalpies are approximately equal. These components can all drop pressure during expansion, yet their energy effects differ.

For ideal-gas air with nearly constant \(c_p\), an enthalpy difference may be approximated by \(c_p\Delta T\). Keeping h in kJ/kg while using \(v^2/2\) in J/kg is a common factor-of-one-thousand error. At 100 m/s the kinetic energy is 5 kJ/kg. That estimate often decides whether an inlet velocity may be omitted from a turbine work calculation.

Evaluate heat loss and exhaust speed

A turbine passes 2.0 kg/s of gas from \(h_1=820\) to \(h_2=600\) kJ/kg. Inlet speed is 40 m/s, exhaust speed 160 m/s and the casing loses 10 kW of heat. Elevations are equal. The gas loses \(2(820-600)=440\) kW of enthalpy flow. Its kinetic-energy rate grows by \(2(160^2-40^2)/2000=24.0\) kW. The unit delivers \(440-24-10=406\) kW shaft power. Counting all 440 kW as shaft output would overstate the result by both the residual exhaust energy and the heat leak.

A separate nozzle using gas at \(h_1=820\) kJ/kg and 40 m/s could reach \(h_2=800\) kJ/kg without a shaft if its speed rose to \(\sqrt{40^2+2(20\,000)}=204\) m/s. This estimate is an energy condition. The required area ratio, pressure drop and possibility of choking also depend on compressible-flow relations.

Extend the same balance to a mixer

Two insulated water lines mix at negligible speed change. One supplies 0.20 kg/s at 360 K and the other 0.30 kg/s at 300 K. A mass balance gives 0.50 kg/s at exit. With equal, constant \(c_p\) and no shaft, summing the two inlet enthalpy rates yields an outlet temperature \([0.20(360)+0.30(300)]/0.50=324\) K. The temperature lies between the inlet values, closer to the higher mass rate. The mixer conserves energy while creating entropy. The next lecture explains how both statements can hold simultaneously and why reversing the mixer without another effect is impossible.

Interpret a measured stagnation temperature

For an insulated diffuser with negligible shaft work, reducing speed from 200 to 40 m/s raises static enthalpy by \((200^2-40^2)/2=19.2\,\mathrm{kJ/kg}\). For air with \(c_p=1.005\,\mathrm{kJ/(kg\,K)}\) that corresponds to a 19.1 K static temperature rise. Stagnation enthalpy \(h+V^2/2\) stays constant even if internal friction produces entropy. A stationary temperature probe that slows the arriving air may approach a stagnation reading, so comparison with a predicted static temperature requires knowing where and how the measurement was taken.

Minimise compression work by selecting an intermediate pressure

A continuous air supply can be compressed in two stages and cooled at intermediate pressure. For a steady adiabatic compressor with negligible kinetic and potential changes, shaft work input is the stream enthalpy rise. With an ideal gas, constant \(c_p,\gamma\), and a reversible stage,

\[w=c_p T_{\rm in}[(p_{\rm out}/p_{\rm in})^a-1],\]

where \(a=(\gamma-1)/\gamma\). This follows by integrating \(ds=c_p\,dT/T-R\,dp/p=0\), then applying \(dh=c_p\,dT\). If both stages use the same isentropic efficiency, divide each ideal rise by that efficiency.

Assume complete intercooling to the original inlet temperature \(T_1\), no pressure losses and prescribed first and last pressures. Put \(r_1=p_i/p_1,\ r_2=p_3/p_i\), so \(r_1r_2=p_3/p_1=r\). Total ideal work is \(c_pT_1[r_1^a+(r/r_1)^a-2]\). Differentiate with respect to \(\ln r_1\); the derivative is \(c_pT_1a(r_1^a-r_2^a)\). The sum has a minimum at equal ratios, giving intermediate pressure \(p_i=\sqrt{p_1p_3}\). This is a geometric mean of absolute pressures. A gauge-pressure ratio would give a completely different design.

Compare two cooled stages with a single compression

Supply air at 100 kPa and 300 K and deliver it at 900 kPa absolute. For \(\gamma=1.4,\ c_p=1.005\,\mathrm{kJ/(kg\,K)}\), an ideal single stage gives \(T_3=300(9^{0.2857})=562.0\,\mathrm K\) and work about 263 kJ/kg. Two equal-ratio stages operate through 300 kPa. Each reaches \(300(3^{0.2857})=410.6\,\mathrm K\) before its outlet or intercooler, requiring \(1.005(110.6)=111.2\,\mathrm{kJ/kg}\). Total work is about 222.4 kJ/kg, roughly 15.5% lower. The intercooler must remove 111.2 kJ/kg between the stages under the ideal complete-cooling assumption.

With equal stage efficiencies of 0.80, each real enthalpy rise becomes 139.0 kJ/kg and the intermediate discharge temperature is about 438 K. Cooling back to 300 K then removes 139.0 kJ per kilogram, with a corresponding load of 27.8 kW at 0.20 kg/s. The equal-ratio choice survives because both stage work expressions acquired the same multiplier. An intercooler that can cool only to 330 K increases the weight of second-stage compression work; the new optimum shifts towards a larger first-stage pressure ratio. A design comparing only compressor shaft power would also need to account for coolant pumping, fan power and pressure losses before choosing the number of stages.

For an incomplete intercooler the optimal shift can be calculated. Take stage two inlet temperature \(T_m=330\) K independently maintained and identical efficiencies. The variable portion of total work is proportional to \(T_1r_1^a+T_m(r/r_1)^a\). Differentiating with respect to log first-stage ratio gives \(T_1r_1^a=T_mr_2^a\), or \(r_1/r_2=(330/300)^{1/a}=1.40\). At overall ratio nine,

\[r_1=\sqrt{9(1.40)}=3.54,\ r_2=2.54.\]

Compressing farther while the air is colder is energetically preferable within this simplified comparison. These ratios presume the cooler can maintain 330 K over its revised duty and that both discharge temperatures stay within their allowable ranges. A compressor map may impose further flow and speed limits beyond the thermodynamic minimum.

At fixed pressure endpoints, the measured intermediate pressure alone would thus be insufficient for diagnosing whether the cooler or a compressor caused an observed power increase.

How much static temperature does a nozzle convert to speed?

Air flows steadily through an insulated nozzle with negligible shaft work and elevation change. Take \(c_p=1005\) J/(kg K). Divide the conserved stagnation enthalpy \(c_pT+u^2/2\) by \(c_p\) to find the exit temperature.

How much static temperature does a nozzle convert to speed?. Horizontal axis: Exit speed (m/s). Vertical axis: Static temperature (K). Data follow the figure.
At 300 m/s the static temperature is about 44.8 K below stagnation temperature, regardless of pressure in this enthalpy calculation. Predicting exit pressure as well would require an entropy or loss model.
Read values from the plot
Static temperature (K) at selected values of Exit speed (m/s).
Exit speed (m/s)Stagnation temperature 350 KStagnation temperature 400 KStagnation temperature 450 K
0350400450
104344.62394.62444.62
210328.06378.06428.06
316300.32350.32400.32
420262.24312.24362.24

Download all 211 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Change stagnation temperature and heat capacity independently. The speed-related temperature drop follows the energy balance.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

Entropy, irreversibility and useful-work loss

Check a proposed process with the second law and quantify the effect of a finite temperature difference.

From first principles

Separate entropy transfer from entropy generated inside a boundary

For a reversible differential process the thermodynamic definition of entropy is

\[dS=\delta Q_{\rm rev}/T.\]

Irreversible changes reach the same state-function difference but can generate entropy internally. For a closed system exchanging heats \(Q_j\) across boundary portions at known local temperatures \(T_j\), the second law gives an experimentally testable inequality:

\[S_2-S_1=\sum_j\int\frac{\delta Q_j}{T_j}+S_{\rm gen},\qquad S_{\rm gen}\ge0 .\]

To evaluate the left side independently of the actual path, use a reversible path between the same equilibrium states. For an ideal gas the fundamental relation \(Tds=du+p\,dv\), together with \(du=c_vdT\) and \(pv=RT\), yields

\[s_2-s_1=c_v\ln(T_2/T_1)+R\ln(v_2/v_1)\]

for constant specific heat. Inserting this property change into the balance isolates entropy generation of the actual process. A gas might cool and lose entropy while the combined gas plus surroundings generates entropy. For heat exchanged across a wall separating two reservoirs, the two reservoirs’ boundary transfer terms have opposite signs and different temperature denominators.

Background · Entropy generation
\[\dot S_{\rm gen}=\dot S_{\rm system}-\sum\dot Q_j/T_j-\dot S_{\rm mass,in}+\dot S_{\rm mass,out}\]

Use boundary temperatures at which heat actually crosses. All flows, storage and units must refer to the same control volume.

Derivation and applications

Count the entropy generated when two ideal gases mix

Two separated ideal gases can have the same temperature and pressure, yet their mixing increases entropy. Consider distinct nonreacting species in insulated rigid compartments. Remove the separator and let them equilibrate in the common volume. Initially both sides have temperature \(T\) and pressure \(p\), and no shaft work is performed. The total internal energy of ideal gases depends only on temperature, so the final equilibrium temperature stays \(T\). Denote mole numbers by \(n_i\) and total volume by \(V\).

For each species, the entropy change can be calculated along a reversible isothermal expansion into its accessible final volume, even though the actual mixing is irreversible. Integrating \(\delta Q_{\rm rev}/T=p_i\,dV/T=n_iR\,dV/V\) gives

\[\Delta S_i=n_iR\ln(V/V_i).\]

The initial volumes were proportional to mole numbers because \(p\) and \(T\) were common. Thus \(V_i/V=n_i/\sum_jn_j=y_i\), the final mole fraction. Add the species changes and use zero boundary entropy transfer:

\[\Delta S_{\rm mix}=S_{\rm gen}=-R\sum_i n_i\ln y_i .\]

For two gases with \(y\) and \(1-y\), the generation per mole of mixture is maximal when both are equally abundant. The derivative and its zero are

\[\frac{d}{dy}\frac{\Delta S_{\rm mix}}n=R\ln[(1-y)/y]=0\quad\Longrightarrow\quad y=\tfrac12.\]

The entropy change tends to zero when either fraction tends to one. If the compartments contain the same gas and the initial temperatures and pressures already agree, removing the partition does not create distinguishable species; assigning artificial labels would predict a spurious mixing term.

Worked example

Estimate the lost work of mixing two samples

Mix \(1.00\) mol of one ideal gas and \(3.00\) mol of another at \(300\) K. The mole fractions are \(0.250\) and \(0.750\). The generated entropy is

\[-8.314[\ln0.25+3\ln0.75]=18.7\,\mathrm{J/K}.\]

Relative to an environment at \(300\) K, the destroyed work potential is \(300(18.7)=5.61\) kJ. No energy has disappeared from the insulated vessel.

Second application

Compare equal and strongly unequal amounts

For a fixed total of \(4.00\) mol, an equal mixture generates \(4R\ln2=23.1\) J/K. With only \(0.0400\) mol of one species the fractions become \(0.0100\) and \(0.990\). The generation falls to

\[4R[-0.01\ln0.01-0.99\ln0.99]=1.86\,\mathrm{J/K}.\]

Each rare molecule gains access to much more volume, but there are few such molecules; both contributions must be counted before comparing samples.

Try it · Mixing

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Energy bookkeeping is not sufficient

In an insulated two-body experiment, heat lost by one body is gained by the other. That energy balance alone would allow heat to move spontaneously from a colder body to a hotter one. Entropy supplies the missing direction constraint. It is a property of a state. For a simple equilibrium system a reversible differential heat transfer defines \(dS=\delta Q_{\rm rev}/T\). An irreversible process between the same endpoints has the same entropy difference; the actual heat transfer divided by the body temperature need not equal that difference.

For a closed system, the integrated entropy balance reads \(\Delta S=\int \delta Q/T_b+S_{\rm gen}\), where \(T_b\) is the absolute temperature at the boundary where the heat crosses. Entropy generation satisfies \(S_{\rm gen}\ge0\). A system can lose entropy by exporting it in heat or in a mass stream. A negative change in the entropy of a single hot body therefore need not violate the second law.

Background · Why does a small temperature difference produce a second-order loss at fixed conductance?

Let a link of constant conductance \(G\) join reservoirs held at \(T+\Delta T/2\) and \(T-\Delta T/2\). In steady operation the heat current is \(G\Delta T\). Subtract the entropy leaving the hot reservoir from that entering the cold reservoir.

\[\dot S_{\rm gen}=G\Delta T\left(\frac{1}{T-\Delta T/2}-\frac{1}{T+\Delta T/2}\right)=\frac{G(\Delta T)^2}{T^2-(\Delta T/2)^2}.\]

At fixed conductance, halving a small difference approximately quarters the entropy production per second, while it also halves the heat current. If a design must keep the heat rate fixed, halving the difference requires nearly twice the conductance and only halves the production. This distinction matters when comparing a bigger exchanger with the original one.

Calculate a property change with a convenient path

For a calorically perfect ideal gas, combine \(T\,ds=du+p\,dv\) with \(du=c_v\,dT\) and \(p=RT/v\). This gives

\[ds=c_v\,dT/T+R\,dv/v.\]

Replacing \(v\) using the ideal-gas law yields the alternative \(ds=c_p\,dT/T-R\,dp/p\). Integrate between the initial and final equilibrium states. These are property relationships, even when the actual path between states includes friction, throttling or free expansion.

An ideal gas passing through an insulated valve with equal inlet and outlet speeds has \(h_2=h_1\), so its temperatures are equal in the constant-\(c_p\) approximation. Dropping air from 400 to 100 kPa gives \(s_2-s_1=-0.287\ln(100/400)=0.398\) kJ/(kg K). With no heat transfer or other streams, the positive entropy change per kilogram is entirely generated. A reversible insulated expansion turbine would generally produce a lower outlet temperature and shaft work.

Trace entropy across two reservoirs

An insulated conductor transfers 600 W from a reservoir at 400 K to another at 300 K. Its stored energy and entropy are steady. The hot reservoir loses entropy at \(600/400=1.50\) W/K, while the cold one gains \(600/300=2.00\) W/K. The total generation rate is 0.50 W/K. Heat rate is the same at both ends; entropy transfer in that heat differs because the temperatures differ.

\[\dot S_{\rm gen}=\dot Q\left(\frac1{T_c}-\frac1{T_h}\right).\]

If the surroundings defining the available-work reference are at \(T_0=300\) K, the corresponding destruction of available work is \(T_0\dot S_{\rm gen}=150\) W. For these particular reservoirs a reversible engine supplied with 600 W at 400 K could have produced \(600(1-300/400)=150\) W before rejecting the remainder. The conductor instead rejects all 600 W to the cold sink. Energy did not disappear; an opportunity for work was lost.

Locate sources and choose a boundary

A heat exchanger can have little external heat leak yet generate appreciable entropy internally through finite temperature differences and pressure losses. Write \(\dot S_{\rm gen}=\sum_{\rm out}\dot m s-\sum_{\rm in}\dot m s-\sum_j\dot Q_j/T_{b,j}\) for steady operation. Both streams belong inside the same control volume when testing internal heat exchange. If the boundary encloses only one stream, heat crossing the wall carries entropy with it and must appear explicitly. The largest reduction in entropy generation per extra unit of area or pumping effort is a design question. The thermodynamic balance identifies losses without alone determining the economically preferred geometry.

Compare the conditions on a valve and a turbine

Air passes through a steady insulated throttling valve from 400 to 100 kPa with negligible changes of speed. With no shaft work the first law gives equal inlet and outlet enthalpy. For ideal air this implies equal temperature. Its entropy change follows from \(\Delta s=c_p\ln(T_2/T_1)-R\ln(p_2/p_1)=0.287\ln4=0.398\,\mathrm{kJ/(kg\,K)}\). At 0.10 kg/s the entropy generation is 0.0398 kW/K. An ideal adiabatic turbine undergoing the same pressure drop has constant entropy and delivers work as its temperature falls. Pressure ratio alone therefore cannot determine the temperature change across an unfamiliar device.

Obtain a work bound for two finite bodies

The reversible efficiency \(1-T_c/T_h\) describes operation between reservoirs held at fixed temperatures. If the two bodies are finite, each increment of transferred heat changes the temperatures and the instantaneous efficiency. Consider two incompressible blocks in a common insulated enclosure. Their heat capacities \(C_h,C_c\) are taken as constant. A reversible engine operates between them and exports mechanical work until no temperature difference remains. The working fluid returns to its starting state after each incremental cycle, so conservation of entropy for this reversible composite system determines the final temperature.

\[C_h\ln(T_f/T_h)+C_c\ln(T_f/T_c)=0,\]
\[T_f=T_h^{C_h/(C_h+C_c)}T_c^{C_c/(C_h+C_c)}.\]

Energy conservation gives maximum work \(W_{\max}=C_hT_h+C_cT_c-(C_h+C_c)T_f\) for consistent internal-energy references. The reversible final temperature is a weighted geometric mean. If the two blocks are simply put in thermal contact without work output, first-law conservation instead gives the weighted arithmetic mean. The arithmetic mean is larger for unequal initial temperatures; additional energy remains as sensible heat after irreversible contact. These different final temperatures matter when comparing two ways of using the same finite resources.

In a real engine running at finite heat-transfer rates there are temperature differences between each block and the working fluid. Total entropy then increases. For a specified common final temperature the entropy change of the blocks is fixed by state properties; measuring it indicates the departure from the ideal reversible construction without needing the working-fluid cycle.

Compare direct contact and a reversible engine quantitatively

Take a hot assembly of heat capacity 2.0 kJ/K at 450 K and a cooler assembly of 1.0 kJ/K at 300 K. Solving the log balance gives

\[T_f=(450^2\,300)^{1/3}=393.1\,\mathrm K.\]

The hot assembly releases about \(2(450-393.1)=113.8\,\mathrm{kJ}\) and the cold one receives 93.1 kJ. Their difference gives approximately 20.7 kJ of maximum work. Acting as though the initial temperatures stayed at 450 and 300 K throughout would assign an incorrectly high efficiency to later parts of the transfer.

By direct contact the common temperature would be \((2\times450+300)/3=400\,\mathrm K\). The entropy generated is

\[2\ln(400/450)+\ln(400/300)=0.0521\,\mathrm{kJ/K}.\]

If instead a device delivers a measured 12 kJ of work before the blocks reach a common temperature, energy fixes that temperature as \((1200-12)/3=396\,\mathrm K\). The measured process then generates \(2\ln(396/450)+\ln(396/300)=0.0220\,\mathrm{kJ/K}\), a positive value between the two limiting cases. Entropy generation multiplied by an environmental temperature gives destroyed exergy relative to that environment; comparing the finite-body work outputs also requires acknowledging their different final stored energies.

The geometric-mean result has an informative limiting case. If the cold assembly is so large that \(C_c/C_h\) tends to infinity, its temperature remains effectively fixed, and the engine work reduces to \(C_h[(T_h-T_c)-T_c\ln(T_h/T_c)]\). This is the integral of the reversible work recovered as the finite hot block approaches a constant sink. It is smaller than applying the initial Carnot efficiency to all of the hot block’s released heat.

Which mixture generates the most entropy?

Mix streams of the same incompressible liquid at 370 K and 290 K, at equal pressure, with constant \(c_p=4180\) J/(kg K). The energy balance fixes the outlet temperature. Evaluate the outlet entropy minus the mass-weighted inlet entropy using \(c_p\ln T\).

Which mixture generates the most entropy?. Horizontal axis: Hot-stream mass fraction. Vertical axis: Entropy produced per kg (J/kg K). Data follow the figure.
Either pure stream gives zero entropy production. An equal-mass mixture settles at 330 K and produces about 30.9 J/(kg K). The maximum is near, but not exactly at, equal fractions because temperature appears inside a logarithm.
Read values from the plot
Entropy produced per kg (J/kg K) at selected values of Hot-stream mass fraction.
Hot-stream mass fractionAdiabatic mixing of identical liquid
00
0.24824.064
0.530.935
0.75222.177
10

Download all 251 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Move the two inlet temperatures toward each other and watch entropy production vanish throughout the mixture range.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

Phase equilibrium and steam quality

Locate a two-phase state from two independent measurements and use mass fractions to find its volume and energy.

From first principles

Derive the slope of a pure-substance coexistence line

At liquid–vapour equilibrium, transferring a small amount of matter between phases cannot lower the total Gibbs energy. For a pure substance this requires equality of the specific Gibbs energies \(g_f=g_g\) at common temperature and pressure. To find how pressure must change when temperature changes while maintaining coexistence, differentiate this equality along the saturation curve. The fundamental differential \(dg=-s\,dT+v\,dp\) gives

\[-s_f\,dT+v_f\,dp=-s_g\,dT+v_g\,dp .\]

Rearranging expresses the measured slope as the entropy change of vaporization divided by its specific-volume change. Reversible phase change at constant temperature absorbs specific enthalpy \(h_{fg}=T(s_g-s_f)\), so

\[\left(\frac{dp}{dT}\right)_{\rm sat}=\frac{s_g-s_f}{v_g-v_f}=\frac{h_{fg}}{T(v_g-v_f)} .\]

The units are Pa/K. No ideal-gas approximation has been made. If the vapour is dilute and the liquid volume negligible, further substitution can simplify the slope, but this fails near the critical point. The slope describes neighbouring coexistence states; determining a system’s vapour mass fraction additionally requires an extensive property such as specific enthalpy or volume.

Background · Vapour quality
\[x=m_v/(m_v+m_l)\]

This mass fraction applies in a two-phase equilibrium region. Mole fraction, mass fraction and fraction of volume occupied by vapour can be very different.

Derivation and applications

Trace an isentropic pressure change through the saturation dome

A vapour fraction inferred from one property must reproduce the others at the same pressure. Consider a pure substance in local liquid–vapour equilibrium. Let \(x\) be the vapour mass fraction and use subscripts \(f,g\) for saturated liquid and vapour at the current pressure. Neglect interfacial contributions and assume each phase has the tabulated saturation state. Specific extensive properties then obey the lever rule because their totals add over the masses of both phases:

\[s=(1-x)s_f+xs_g=s_f+xs_{fg},\]
\[h=h_f+xh_{fg}.\]

In a steady adiabatic reversible expansion the entropy balance gives

\[s_2=s_1.\]

At the specified exit pressure solve the entropy relation before using the enthalpy relation:

\[x_{2s}=(s_1-s_{f,2})/s_{fg,2},\]
\[h_{2s}=h_{f,2}+x_{2s}h_{fg,2}.\]

This interpolation is physical only when \(0\le x_{2s}\le1\). For an actual adiabatic turbine with negligible kinetic-energy change, use isentropic efficiency \(\eta_t=(h_1-h_2)/(h_1-h_{2s})\) and check the actual phase state separately:

\[h_2=h_1-\eta_t(h_1-h_{2s}),\]
\[x_2=(h_2-h_{f,2})/h_{fg,2}\]

if the actual outlet is still a mixture. Irreversibility reduces extracted work, which can leave the exhaust drier at the same pressure. A drier exit therefore does not by itself demonstrate higher efficiency.

Worked example

Infer equilibrium quality for two expansion histories

At a low-pressure outlet take rounded steam properties \(h_f=192\), \(h_{fg}=2393\) kJ/kg, \(s_f=0.649\) and \(s_{fg}=7.50\) kJ/(kg K). Steam enters with \(h_1=3200\) kJ/kg and \(s_1=6.65\) kJ/(kg K). The reversible quality is \((6.65-0.649)/7.50=0.800\), giving \(h_{2s}=2107\) kJ/kg. For \(\eta_t=0.800\), the actual exit enthalpy is about \(2326\) kJ/kg and the quality \(0.892\). The actual specific work is about \(874\) kJ/kg.

Second application

Detect when a reported quality has no physical meaning

At the same outlet pressure an independent calculation gives \(h_2=2630\) kJ/kg. Interpolating would give

\[x=(2630-192)/2393=1.019.\]

Since the saturated vapour enthalpy is only \(2585\) kJ/kg, the enthalpy lies above the saturation range. The outlet is superheated; finding its temperature requires superheated-vapour properties. Reporting a vapour fraction above unity would hide a change of thermodynamic region.

Try it · Turbine quality

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Temperature can stay fixed while heat enters

In an open pan at a fixed ambient pressure, liquid water begins to boil at a particular temperature. Additional heat can then convert liquid to vapour while the temperature remains close to that value. Specifying both saturation temperature and saturation pressure of a pure substance does not locate a unique mixture state. Along the coexistence curve they are linked, and the fraction of material in each phase supplies the missing information. Outside that curve pressure and temperature can usually be used as independent coordinates for a simple compressible substance.

Define quality \(x=m_g/(m_f+m_g)\) as the vapour mass fraction, using subscripts \(f\) for saturated liquid and \(g\) for saturated vapour. A property such as volume or enthalpy is additive over the two masses when interfacial contributions are negligible. Writing \(V=m_f v_f+m_gv_g\) and dividing by total mass gives the mixing relation. The same derivation applies to specific internal energy, enthalpy and entropy.

\[v=v_f+x(v_g-v_f),\]
\[h=h_f+xh_{fg},\]
\[h_{fg}=h_g-h_f .\]

Quality lies between zero and one in a saturated mixture. A calculated value beyond either endpoint signals a single-phase state or inconsistent measurements. Temperature does not interpolate: both phases in equilibrium have the same temperature.

Distinguish vapour mass from space occupied

A closed vessel contains 2.00 kg of saturated water and steam at approximately 100 kPa in 0.500 m³. Use the supplied rounded values \(v_f=0.00104,\ v_g=1.694\,\mathrm{m^3/kg}\),

\[h_f=417.5,\ h_{fg}=2258\,\mathrm{kJ/kg}.\]

The measured specific volume is 0.250 m³/kg. Quality follows as \((0.250-0.00104)/(1.694-0.00104)=0.1471\). Thus vapour mass is 0.294 kg while 1.706 kg remains liquid.

The vapour occupies \(0.2941(1.694)=0.4982\,\mathrm{m^3}\), almost the entire vessel. The liquid occupies roughly 0.0018 m³. Specific enthalpy is

\[417.5+0.1471(2258)=749.6\,\mathrm{kJ/kg}.\]

Specific internal energy follows from \(u=h-pv=749.6-100(0.250)=724.6\,\mathrm{kJ/kg}\) when using kPa and m³/kg. A level indicator measures occupied volume; using its reading directly as a mass fraction would give a large error.

Connect latent heat to the coexistence curve

For two pure phases in equilibrium their specific Gibbs free energies are equal. Along the coexistence line this equality persists, so \(dg_f=dg_g\). From \(dg=v\,dp-s\,dT\) one obtains

\[dp_{\rm sat}/dT=(s_g-s_f)/(v_g-v_f)=h_{fg}/[T(v_g-v_f)].\]

At about 373 K using the same values, the slope is

\[2258/[373(1.693)]=3.58\,\mathrm{kPa/K}.\]

A small increase of boiling pressure by 3.6 kPa therefore raises saturation temperature by about one kelvin locally. Larger changes require integrating the changing properties or reading a saturation table rather than treating this local slope as a constant.

Predict flash after throttling

A saturated liquid with inlet enthalpy 500 kJ/kg passes through an insulated valve to the pressure of the drum above. With negligible work and velocity change, enthalpy remains 500 kJ/kg. The downstream quality is therefore

\[(500-417.5)/2258=0.0365.\]

Only about 3.7% of the water flashes by mass, but the large specific volume of the vapour can make its occupied volume dominate the downstream pipe.

Trace a saturated mixture along a constant-volume path

The drum example determines one state. If a sealed rigid vessel is heated, its pressure and temperature change together along saturation while its specific volume remains fixed. Provided equilibrium is maintained and no other phase appears, the quality at every pressure is

\[x=(v-v_f)/(v_g-v_f).\]

The energy equation for the vessel is \(Q=\Delta U\) when it does no boundary or shaft work. Replacing internal-energy change by enthalpy change would add the spurious \(V\Delta p\) term of a rigid container.

Quality does not change solely because latent heat has entered. Differentiate \(v=(1-x)v_f+xv_g\) along the saturation curve at fixed \(v\). This gives

\[\frac{dx}{dT}=-\frac{(1-x)\,dv_f/dT+x\,dv_g/dT}{v_g-v_f}.\]

Saturated liquid usually expands as temperature rises while saturated vapour specific volume decreases over the ordinary water range. The sign therefore depends on the initial mixture and local property slopes. A vessel containing almost all liquid by volume can, under some conditions, follow the saturated-liquid boundary on heating rather than drying out. Determine the actual phase region from the property data after each change. When \(v\) lies outside the interval between \(v_f\) and \(v_g\), a saturated quality formula is no longer applicable.

Find how much energy changes phase in a sealed vessel

Take 1.00 kg of water in a rigid 0.300 m³ vessel. Use rounded saturation data at 100 kPa:

\[v_f=0.00104,\ v_g=1.694\,\mathrm{m^3/kg},\ u_f=417.4,\ u_g=2506\,\mathrm{kJ/kg}.\]

At 200 kPa use \(v_f=0.00106,\ v_g=0.8857,\ u_f=504.5,\ u_g=2529\,\mathrm{kJ/kg}\). The volume bounds contain 0.300 m³/kg at both pressures. Initial quality is \((0.300-0.00104)/(1.694-0.00104)=0.1766\); final quality is

\[(0.300-0.00106)/(0.8857-0.00106)=0.3379.\]

Thus about 0.161 kg additionally evaporates.

Mixture internal energies are \(417.4+0.1766(2506-417.4)=786.3\,\mathrm{kJ/kg}\) and \(504.5+0.3379(2529-504.5)=1188.6\,\mathrm{kJ/kg}\), giving heat input about 402 kJ. Merely multiplying evaporated mass by one latent heat would overlook the sensible energy changes in each phase and the variation of saturation properties. As an independent check, \(\Delta H=\Delta U+V\Delta p\) exceeds the required heat by \(0.300(200-100)=30.0\,\mathrm{kJ}\). If additional heating brings saturated vapour specific volume down to 0.300 m³/kg, the last liquid disappears. Beyond that state the fixed-volume path enters the superheated region and one must determine temperature using a single-phase equation of state or superheated-vapour data.

The vapour volume fraction in the second state is \(m x v_g/V=0.3379(0.8857)/0.300=0.998\) approximately. Although about one third of the mass is vapour, almost every part of the vessel volume is vapour-filled. A level probe that detects a very small liquid volume is consistent with the presence of substantial residual liquid mass. This has a direct consequence for rounding: replacing \(v_f\) by zero only gives a modest error in calculated quality here, but using that same approximation to predict the remaining liquid depth gives a nonsensical zero. Retain the finite liquid volume whenever the question concerns an interface height or the mass recovered through a bottom drain.

The units of the property table matter just as much as the phase labels when predicting a small liquid inventory.

Can an equation of state predict energy changes during expansion?

A caloric model \(du=c_v\,dT\) works for an ideal gas. To discover the extra term for a real fluid, let \(v\), \(s\) and \(u\) denote molar volume, entropy and energy for a single homogeneous phase. At a fixed composition the fundamental relation is

\[du=T\,ds-p\,dv.\]

Introduce the Helmholtz energy \(f=u-Ts\). Then \(df=-s\,dT-p\,dv\). Equality of the two mixed partial derivatives of the smooth function \(f(T,v)\) gives the Maxwell relation \((\partial s/\partial v)_T=(\partial p/\partial T)_v\).

Now expand \(ds\) in \(T,v\). The term \(T(\partial s/\partial T)_v\) equals \(c_v\), obtained directly by holding \(v\) fixed in the fundamental relation. Substituting both coefficients gives

\[du=c_v\,dT+\left[T\left(\frac{\partial p}{\partial T}\right)_v-p\right]\,dv.\]

The bracket has units of pressure. For \(p=RT/v\) it vanishes. For a van der Waals model \(p=RT/(v-b)-a/v^2\), the repulsive volume correction cancels between the two terms and the attraction term leaves \(a/v^2\). Assuming constant \(c_v\), integration yields

\[\Delta u=c_v(T_2-T_1)+a(1/v_1-1/v_2).\]

An insulated, rigid container contains a gas on one side of a removable internal partition and vacuum on the other. Removing the partition causes no external boundary work and exchanges no heat. States before and after settling therefore have equal internal energy. Let \(T_1=300\,\mathrm K\), \(v_1=0.00200\,\mathrm{m^3\,mol^{-1}}\), \(v_2=0.00400\,\mathrm{m^3\,mol^{-1}}\), \(a=0.150\,\mathrm{Pa\,m^6\,mol^{-2}}\), \(b=4.0\times10^{-5}\,\mathrm{m^3\,mol^{-1}}\) and \(c_v=24.0\,\mathrm{J\,mol^{-1}K^{-1}}\). The volume contribution is

\[0.150(500-250)=37.5\,\mathrm{J\,mol^{-1}}.\]

To keep energy constant the temperature falls by \(37.5/24.0=1.56\,\mathrm K\), to \(298.44\,\mathrm K\). The differential identity links the equilibrium endpoints even though the actual expansion was irreversible. The value of \(b\) matters for their pressures and cancels from this energy change.

Gas mixtures, humidity and condensation

Translate relative humidity into a water mass balance and determine how much condensate a cooling coil removes.

From first principles

Obtain humidity ratio from partial pressures and dry-air mass

Treat moist air as an ideal mixture of dry air and water vapour occupying the same volume \(V\) at temperature \(T\). Dalton's law gives total pressure \(p=p_{da}+p_v\). For each component \(m_i=p_iV/(R_iT)\), so dividing vapour mass by dry-air mass cancels the shared volume and temperature:

\[\omega=\frac{m_v}{m_{da}}=\frac{R_{da}}{R_v}\,\frac{p_v}{p-p_v}\simeq0.622\frac{p_v}{p-p_v}.\]

Relative humidity is a different observable. It compares actual vapour partial pressure with the saturation pressure at the same temperature. Cooling without water removal keeps \(\omega\) constant, and approximately constant total pressure then keeps \(p_v\) constant until the saturation curve reaches it:

\[\varphi=p_v/p_{\rm sat}(T),\]
\[p_{\rm sat}(T_{\rm dew})=p_v .\]

Below the dew point some water can leave the gas as liquid, while dry-air mass is conserved. A steady coil receiving humidity ratio \(\omega_i\) and delivering \(\omega_o\) therefore removes condensate at rate \(\dot m_{da}(\omega_i-\omega_o)\). Inferring the same removal from relative humidity alone would ignore its dependence on temperature.

Derivation and applications

Measure the bypass fraction of a cooling and dehumidifying coil

Humid air crossing a coil may leave warmer and wetter than air in equilibrium with the coldest effective surface. A common reduced model treats a fraction \(b\) of the dry-air stream as bypassing the surface while the remainder reaches a saturated state at the apparatus dew-point temperature. Consider a steady coil at nearly constant total pressure, neglect fan work and heat gains, and use dry-air mass as the conserved basis. Denote inlet, saturated-surface and mixed outlet states by \(i,s,o\), with humidity ratio \(\omega\) and moist-air enthalpy \(h\) per kilogram of dry air.

Water-vapour and mixed-stream enthalpy balances give two independent ways to estimate the same bypass fraction:

\[\omega_o=b\omega_i+(1-b)\omega_s,\]
\[h_o=bh_i+(1-b)h_s.\]

Solving either for \(b\) exposes a consistency check on measured data and the assumed single surface state:

\[b=\frac{\omega_o-\omega_s}{\omega_i-\omega_s}=\frac{h_o-h_s}{h_i-h_s}.\]

The condensed water remains a separate outlet from the coil. With condensate leaving at liquid enthalpy \(h_\ell\) in the same reference convention, an overall balance gives positive heat removal

\[\dot m_\ell=\dot m_{da}(\omega_i-\omega_o),\]
\[\dot Q_{\rm out}=\dot m_{da}(h_i-h_o)-\dot m_\ell h_\ell .\]

The mixed-state model requires

\[0\le b\le1.\]

It also requires incoming air wet enough for condensation on the assumed surface. A dry surface with solely sensible cooling cannot be represented by forcing a saturated leaving branch.

Worked example

Evaluate air and water leaving a coil

Use \(\omega_i=0.0160\), \(\omega_s=0.00760\) kg/kg dry air, \(h_i=71.0\), \(h_s=29.3\) kJ/kg dry air and \(b=0.250\). Then \(\omega_o=0.00970\) and \(h_o=39.7\) kJ/kg dry air. With \(1.20\) kg/s dry air, the condensate rate is \(0.00756\) kg/s. For \(h_\ell=42.0\) kJ/kg, heat removal is

\[1.20(71.0-39.725)-0.00756(42.0)=37.2\,\mathrm{kW}.\]

Second application

Test whether three measurements share one apparatus dew point

On another run with the same inlet and assumed surface, measured outlet values are \(\omega_o=0.01096\) and \(h_o=41.8\) kJ/kg dry air. The humidity ratio implies \(b=0.400\), while enthalpy gives \(b=0.300\). At \(b=0.400\) the model would predict \(h_o=46.0\) kJ/kg. The \(4.2\) kJ/kg discrepancy indicates that measurement uncertainty, a more distributed surface temperature or another heat transfer must be considered before inferring a unique bypass fraction.

Try it · Coil bypass

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Choose a quantity that survives condensation

A ventilation duct can carry an unchanged mass flow of dry air while water evaporates into it or condenses out. It is therefore convenient to express water content and mixture energy per kilogram of dry air. Model the dry air and water vapour as ideal gases sharing a common temperature and total volume. The partial pressure of each gas is the pressure it would exert if it occupied this volume alone. Dalton’s law gives

\[p=p_a+p_v.\]

Relative humidity \(\phi=p_v/p_{\rm sat}(T)\) describes proximity to saturation at the current temperature. It is not the mass fraction of water. For humidity ratio \(w=m_v/m_a\), divide the two ideal-gas mass equations. The common temperature and volume cancel, leaving a ratio of molar masses multiplied by the partial-pressure ratio.

\[w=\frac{M_v}{M_a}\frac{p_v}{p-p_v}\simeq0.622\frac{p_v}{p-p_v},\]
\[w_{\rm sat}(T)=0.622\frac{p_{\rm sat}(T)}{p-p_{\rm sat}(T)} .\]

Before any water condenses during cooling at constant total pressure, the humidity ratio and vapour partial pressure remain fixed. Relative humidity rises because saturation pressure falls. The dew point is the temperature at which saturation pressure equals that fixed vapour pressure. Once that point is crossed, further cooling can remove water.

Find water removal and the associated cooling duty

Air enters a coil at 30 °C, 100 kPa and 60% relative humidity, and leaves saturated at 12 °C. Use \(p_{\rm sat}(30)=4.24\) kPa and \(p_{\rm sat}(12)=1.40\) kPa. The inlet vapour partial pressure is 2.544 kPa, giving \(w_1=0.01624\) kg water per kg dry air. The outlet ratio is \(w_2=0.00883\). For dry-air flow 0.50 kg/s the condensate flow is \(0.50(0.01624-0.00883)=0.00371\,\mathrm{kg/s}\), about 13.3 kg/h.

Using a 0 °C liquid-water reference, approximate moist-air enthalpy per kilogram dry air by \(h=1.005T+w(2501+1.86T)\) kJ/kg dry air with \(T\) in °C. The duct streams carry about 71.7 and 34.3 kJ/kg dry air. Condensate leaving at 12 °C carries \(h_l\simeq4.18(12)=50.2\,\mathrm{kJ/kg}\). Energy conservation gives heat removed per kilogram dry air as \(h_1-h_2-(w_1-w_2)h_l\), approximately 37.0 kJ/kg dry air, or 18.5 kW.

Separate humidity ratio from relative humidity

Suppose the outlet stream is reheated to 20 °C without adding water. Its vapour pressure remains 1.40 kPa at the same total pressure. Since \(p_{\rm sat}(20)=2.34\,\mathrm{kPa}\), the new relative humidity is 59.8%. Neither evaporating water nor drying the air was required during this reheat. A sensor reporting 60% at both the inlet and reheated outlet therefore describes two air streams containing rather different masses of water. The coil water balance, written on the dry-air basis, explains the apparent coincidence.

Bracket an unknown dew point

At the original inlet the vapour pressure was 2.544 kPa. Suppose a saturation table gives 2.487 kPa at 21 °C and 2.644 kPa at 22 °C. Linear interpolation over this short interval puts the dew point at \(21+(2.544-2.487)/(2.644-2.487)=21.36^\circ\mathrm C\). A coil surface warmer than this value cannot start condensing the entering air locally under the stated conditions.

Balance an adiabatic spray chamber

A direct evaporative cooler behaves differently from a refrigerated cooling coil. Water is added to an airstream, the dry-bulb temperature falls, and the humidity ratio increases. Assume steady operation, negligible shaft work and heat leakage, unchanged total pressure, and no liquid droplets carried out. Express enthalpy per kilogram dry air. The dry-air flow is conserved; added liquid flow per kilogram dry air equals \(w_2-w_1\). The resulting energy balance is

\[h_1+(w_2-w_1)h_{\ell,\rm in}=h_2.\]

Use the same enthalpy reference for liquid and moist air. If the added water has low liquid enthalpy on that reference, the moist-air enthalpy is approximately constant. Often the recirculated liquid is near the leaving-air temperature; the more accurate energy equation above can be used without that approximation. An ideal infinitely long saturated contactor has \(\phi_2=1\), but a finite cooler generally leaves unsaturated air. An outlet temperature or a contact effectiveness is needed in addition to the balances unless saturation is specified.

With constant heat capacities one may write \(h_2=c_{pa}T_2+w_2(h_{g0}+c_{pv}T_2)\). Substituting this form into the balance and grouping the unknown \(w_2\) shows explicitly which measured quantities are needed. The process cannot cool below the adiabatic saturation limit for the given inlet state and water supply merely by increasing the spray rate.

Check outlet humidity and water consumption

A cooler receives air at 35 °C and 100 kPa with inlet humidity ratio 0.0080 kg/kg dry air and dry-air flow 0.60 kg/s. Its measured outlet temperature is 23 °C and liquid makeup enters at 20 °C. Use \(h=1.005T+w(2501+1.86T)\) kJ/kg dry air and \(h_\ell=4.18T\) kJ/kg. The inlet carries \(1.005(35)+0.008[2501+1.86(35)]=55.70\,\mathrm{kJ/kg}\) dry air; liquid enters with \(h_\ell=83.6\,\mathrm{kJ/kg}\).

The outlet equation is \(55.70+(w_2-0.0080)83.6=1.005(23)+w_2[2501+1.86(23)]\), giving \(w_2=0.01297\,\mathrm{kg/kg}\) dry air. Thus liquid consumption is \(0.60(0.01297-0.0080)=0.00298\,\mathrm{kg/s}\), or about 10.7 kg/h. The outlet vapour pressure is

\[100(0.01297)/(0.622+0.01297)=2.04\,\mathrm{kPa}.\]

At a supplied saturation pressure of 2.81 kPa for 23 °C, this corresponds to about 73% relative humidity, consistent with a finite contact process.

Treating air as a dry sensible stream would suggest a cooling duty of roughly \(0.60(1.005)(35-23)=7.24\,\mathrm{kW}\) removed from the cabinet. In this adiabatic device most of the sensible decrease supplies evaporation inside the boundary; no corresponding cooling-coil duty exists. A downstream process sensitive to water content may therefore react very differently to evaporative cooling and cooling plus dehumidification, even when both report the same outlet dry-bulb temperature.

An independent check can be made by weighing the makeup reservoir over a stable ten-minute test. At the predicted consumption it should lose about \(10.7/6=1.78\) kg, provided no liquid is stored in the spray circuit during that interval. A greater measured loss together with the same outlet humidity suggests entrained droplets, drainage or leakage rather than necessarily more evaporation. A humidity probe downstream of an effective droplet separator and a separate liquid-drain measurement distinguish those paths and make the water balance close.

Identify condensation from a humidity-ratio chart

At a total pressure of 101.325 kPa,

\[w=0.62198\,p_v/(p-p_v),\]
\[p_v=\phi\,p_{\rm sat}(T).\]

The plot uses the Buck saturation-pressure correlation over liquid water. Follow a sealed parcel cooled at constant pressure with no condensation until it reaches saturation.

Identify condensation from a humidity-ratio chart. Horizontal axis: Dry-bulb temperature (°C). Vertical axis: Water vapour (g/kg dry air). Data follow the figure.
Air at 30°C and 65% relative humidity contains about 17.4 g/kg dry air. Following that horizontal humidity ratio to the saturation curve gives a dew point near 22.7°C. Continuing cooling at constant total water content then produces liquid condensate.
Read values from the plot
Water vapour (g/kg dry air) at selected values of Dry-bulb temperature (°C).
Dry-bulb temperature (°C)Relative humidity 35%Relative humidity 65%Relative humidity 100%
51.88013.50065.402
153.68526.878910.646
256.882812.90520.078
3512.32823.29136.57
4521.31540.78365.039

Download all 201 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Choose an initial temperature and relative humidity, then follow the horizontal parcel-water line to saturation.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

Useful work and exergy destruction

Evaluate the useful-work potential of a steady stream and distinguish energy conservation from the destruction of useful-work potential.

From first principles

Derive maximum useful work relative to an environment

For a closed body changing toward equilibrium with surroundings at \(T_0,p_0\), consider the reversible path that gives the largest possible useful work. Neglect bulk kinetic and gravitational energy. With heat \(Q_0\) positive into the body and total boundary plus shaft work \(W\) positive out, the first law gives

\[W=U_i-U_f+Q_0.\]

Reversible heat exchange with this environment requires

\[Q_0=T_0(S_f-S_i).\]

Part of total work simply displaces ambient pressure, so

\[W_{\rm useful,rev}=U_i-U_f+T_0(S_f-S_i)-p_0(V_f-V_i).\]

Choose the final state as the dead state, denoted by subscript zero. Grouping the available initial differences defines nonflow physical exergy:

\[B=(U-U_0)+p_0(V-V_0)-T_0(S-S_0).\]

If the process generates entropy, the same first and second law combination lowers the useful work by \(T_0S_{\rm gen}\). The expression depends on the specified surrounding state and assumes no other heat reservoirs or chemical changes. A stream crossing a control volume carries its pressure flow work as well, giving a distinct enthalpy-based expression for flow exergy.

Background · Exergy destruction
\[\dot X_{\rm dest}=T_0\dot S_{\rm gen}\]

The environmental reference temperature enters in kelvin. Irreversibility destroys useful-work potential even when the total energy balance closes.

Derivation and applications

Derive the work potential of a compressed flowing gas

A stream can deliver useful work by cooling or by expanding, even when no fuel or chemical reaction is involved. Choose a steady reference environment at \(T_0,p_0\) with the same gas composition. Consider one kilogram taken reversibly from its inlet state to the environmental state. Neglect kinetic and potential energy. Let \(q_0\) be heat supplied from the environment, positive into the device, and \(w\) shaft work delivered. The steady energy balance includes flow work in enthalpy:

\[w=h-h_0+q_0 .\]

The only external heat exchange occurs with the environment. Reversibility then gives \(s_0-s=q_0/T_0\), eliminating the unmeasured heat transfer. The maximum work is the specific physical flow exergy

\[b=(h-h_0)-T_0(s-s_0).\]

For an ideal gas with constant \(c_p\) and \(R\), insert \(dh=c_p\,dT\) and \(ds=c_p\,dT/T-R\,dp/p\). Integrate relative to \(T_0,p_0\):

\[b=c_p[(T-T_0)-T_0\ln(T/T_0)]+RT_0\ln(p/p_0).\]

The pressure term survives at ambient temperature. Near \(T=T_0\) the thermal term is quadratic in the temperature difference because energy and the ambient heat contribution cancel to first order. The formula describes work relative to a specified reference and assumes the inlet and outlet composition is the same. An actual dissipative path destroys part of the reversible work potential.

Worked example

Estimate the work available from warm compressed air

Take air at \(T=360\) K, \(p=300\) kPa entering an environment at \(T_0=300\) K and \(p_0=100\) kPa. With \(c_p=1.005\) and \(R=0.287\) kJ/(kg K), the thermal contribution is \(1.005[60-300\ln1.2]=5.33\) kJ/kg. The pressure contribution is \(0.287(300)\ln3=94.6\) kJ/kg. Total available work is approximately \(99.9\) kJ/kg, mostly associated with pressure.

Second application

Account for loss in an ambient-temperature throttle

Let \(0.100\) kg/s of ideal air throttle adiabatically from \(300\) to \(100\) kPa, both at \(300\) K. Enthalpy stays constant, no shaft work is extracted, and the exergy destruction is \(0.100(94.6)=9.46\) kW. Independent entropy accounting gives \(\dot S_{\rm gen}=\dot mR\ln3=0.0315\) kW/K. Its product with the ambient \(300\) K recovers the same \(9.46\) kW. A device balancing energy perfectly can therefore expend substantial work potential.

Try it · Flow exergy

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

How much work is lost when two finite bodies touch?

Two insulated metal blocks start at different temperatures. A small cyclic heat engine could transfer heat from one to the other and deliver shaft work until the temperatures equalise. Simply bringing the blocks into thermal contact also gives a common final temperature, but it conserves a different quantity. Calculate the two end states before estimating how much work the initial temperature difference made available.

Assume constant positive heat capacities \(C_h,C_c\), no phase change, no external heat exchange and no mechanical work by either block. In direct passive contact no outside work is produced. The total energy change is therefore zero, giving \(T_{\rm mix}=(C_hT_h+C_cT_c)/(C_h+C_c)\). If the intervening engine instead operates reversibly, each small entropy transfer leaving the hot block equals the entropy entering the cold one. At the final common temperature \(T_f\),

\[C_h\ln(T_f/T_h)+C_c\ln(T_f/T_c)=0,\]
\[T_f=\exp\left[\frac{C_h\ln T_h+C_c\ln T_c}{C_h+C_c}\right].\]

Here all temperatures are absolute. More formally the logarithms can be taken of ratios to the same reference temperature; that reference cancels. The weighted geometric mean lies below the weighted arithmetic mean. The reversible final state thus contains less internal energy than the passive final state. The difference has emerged as work,

\[W_{\max}=(C_h+C_c)(T_{\rm mix}-T_f).\]

An irreversible engine generates entropy and ends at a higher common temperature with smaller available work.

Take two blocks with capacities of 1.2 kJ/K, initially at 360 K and 280 K. Passive contact ends at 320.0 K; the reversible engine ends at \(\sqrt{360\times280}=317.49\) K and delivers 6.02 kJ. Passive contact generates 0.01890 kJ/K of entropy. To visualise the reversible path, let \(s\) be the entropy transferred from one block into the other. The instantaneous temperatures are \(T_h(s)=T_h(0)e^{-s/C_h}\) and \(T_c(s)=T_c(0)e^{s/C_c}\). The next increment of work is \((T_h-T_c)ds\), so the signed area between the two temperature curves reproduces the total work.

The block temperatures converge as entropy is transferred; alongside, the accumulated engine work flattens at the common temperature.
The slope of the work curve is the temperature gap. It vanishes at the reversible end state even though the engine delivered finite work earlier.

The scaling becomes particularly clear for equal capacities \(C\) when the starting temperatures are \(T_m+\Delta\) and \(T_m-\Delta\). The mixed temperature is \(T_m\), while the reversible final temperature is \(T_m\sqrt{1-(\Delta/T_m)^2}\). Expanding the square root for small temperature gaps gives

\[W_{\max}\simeq C\Delta^2/T_m.\]

For \(T_m=320\) K and \(\Delta=40\) K this is 6.0 kJ, close to the exact 6.02 kJ. Halving the temperature gap at the same mean temperature gives roughly a quarter of the work. The energy initially contained in the warmer block above the mean temperature scales only linearly with the gap, so that energy alone is a poor measure of usable work.

If the surroundings never exchange heat with either block, should their temperature appear in this maximum-work calculation?

Work through the solution

The reversible engine can use only the two specified bodies. Their initial states and conservation of their total entropy determine how far the work extraction goes. A different problem allows ultimate equilibration with an external reservoir at \(T_0\). In that enlarged problem the standard exergy destruction associated with the irreversible contact is \(T_0 S_{\rm gen}\). These work comparisons have different permitted end states. The notebook keeps the enclosure insulated and checks the work using the energy balance on both bodies throughout the exchange.

Interactive calculation · Finite source temperatures

Vary the notebook inputs and compare both plotted observables. The same equations generate the browser curves and the notebook reference; fixed material, geometry and model assumptions are stated in the readout.

Download the editable notebook for this example

Interactive calculation · Finite source work

Vary the notebook inputs and compare both plotted observables. The same equations generate the browser curves and the notebook reference; fixed material, geometry and model assumptions are stated in the readout.

Download the editable notebook for this example

Specify the surroundings before rating a resource

A warm stream contains energy relative to a chosen reference. The amount that could become useful work depends on the surroundings available to receive heat. If stream and environment reach mutual thermal and mechanical equilibrium, there is no further physical work potential associated with their difference. This equilibrium is the physical dead state at \(T_0,p_0\). Exclude chemical reactions here and consider a steady flow with constant composition.

Imagine a reversible device that takes a stream from its current state to the dead state while interacting thermally only with the environment. The steady first law relates delivered work to changes in stream enthalpy, kinetic and potential energy, and heat. The reversible entropy balance gives heat received from the environment \(q_0=T_0(s_0-s)\). Eliminating that heat gives the specific flow exergy

\[\psi=(h-h_0)-T_0(s-s_0)+V^2/2+g(z-z_0).\]

Use consistent units for the kinetic and potential terms. The entropy contribution reduces the fraction of enthalpy that a reversible device can turn into useful work. At the dead state, with the same velocity and elevation as the reference, that work potential vanishes.

Cool a liquid to the environment

Take a stream of liquid water at approximately ambient pressure, 360 K, with negligible motion and elevation change. It flows at 0.20 kg/s towards a large environment at 300 K. Assume \(c_p=4.18\,\mathrm{kJ/(kg\,K)}\) constant. Integration gives

\[h-h_0=c_p(T-T_0),\]
\[s-s_0=c_p\ln(T/T_0).\]

The stream’s specific physical exergy is therefore

\[4.18[60-300\ln(360/300)]=22.2\,\mathrm{kJ/kg}.\]

Its enthalpy difference is much larger, 250.8 kJ/kg.

Cooling all the way to 300 K makes at most \(0.20(22.2)=4.44\,\mathrm{kW}\) of useful work available, even though the stream releases 50.16 kW of heat. Direct heat exchange with the environment delivers no shaft work. The environment entropy gain is \(50.16/300=0.1672\,\mathrm{kW/K}\), while the stream loses \(0.20(4.18)\ln(360/300)=0.1524\,\mathrm{kW/K}\). The difference, about 0.0148 kW/K, is the entropy production rate. Multiplication by \(T_0\) gives the lost 4.44 kW of work potential.

Include heat crossing another temperature boundary

Heat \(Q\) supplied reversibly by a reservoir at a uniform boundary temperature \(T_b\) carries exergy \(Q(1-T_0/T_b)\). This follows by comparing its energy with the environmental heat required to discharge the associated entropy \(Q/T_b\). A heat input of 10 kW from a 600 K reservoir in a 300 K environment carries 5 kW of exergy. A transfer from a finite cooling stream has changing source temperature and requires integration, as in the water example. Irreversibility in the device destroys exergy at rate \(T_0\dot S_{\rm gen}\); directing heat to a useful secondary process can retain part of the exergy that direct cooling would destroy.

Include the work potential of pressure

For an ideal gas already at \(T_0\), an elevated pressure still gives physical flow exergy \(RT_0\ln(p/p_0)\). Air at 300 K and twice environmental pressure has about \(0.287(300)\ln2=59.7\,\mathrm{kJ/kg}\) of pressure-related work potential although its ideal-gas enthalpy equals that at the dead state.

Derive the least work needed to heat a finite stream

Heat pumps are commonly compared by heat delivered per unit of electrical work. A second-law comparison additionally accounts for the temperature at which heat is delivered. Consider a steady stream heated from \(T_i\) to \(T_o\) at nearly environmental pressure, with constant heat capacity rate \(C=\dot m c_p\). A reversible heat pump extracts heat from surroundings at \(T_0\) and delivers it through a temperature-matched sequence of infinitesimal condensers. For one increment \(dQ=C\,dT\) at stream temperature \(T\), the reversed Carnot relation gives

\[dW_{\min}=dQ(1-T_0/T).\]

Integrating over the stream yields

\[W_{\min}=C[(T_o-T_i)-T_0\ln(T_o/T_i)].\]

This is the increase of its physical flow exergy, and is smaller than evaluating the Carnot work factor at the final high temperature for the whole heat duty. A device that condenses at a single temperature above the warmest outlet generates entropy during delivery to the colder portions. The result assumes that the source of heat is the environment at \(T_0\); a colder source would introduce an additional resource requirement.

For steady equipment receiving only electricity and environmental heat, with negligible parasitic flows, a meaningful second-law efficiency is the stream’s exergy increase divided by actual electrical input. Electric power is entirely work potential, whereas a kilowatt of heat near room temperature carries only a small fraction of a kilowatt of exergy.

Compare a heat pump with a resistance heater

Water flows at 0.10 kg/s from 293 K to 333 K in a 293 K environment. With \(c_p=4.18\,\mathrm{kJ/(kg\,K)}\), heat duty is \(0.418(40)=16.72\,\mathrm{kW}\). The exergy increase is \(0.418[40-293\ln(333/293)]=1.05\,\mathrm{kW}\) approximately. This relatively small figure reflects the modest average temperature lift. A well-insulated heat pump drawing 4.20 kW from the electrical supply has heating COP \(16.72/4.20=3.98\) and exergy efficiency about 25%. Its surroundings provide 12.52 kW of heat under the stated energy balance.

A resistance heater supplying the identical water service draws 16.72 kW when its losses to the room are negligible. It is nearly 100% efficient on the simple electrical-energy-to-heat basis, yet its exergy efficiency is only about 6.3%. For the heat pump the implied destruction of work potential is \(4.20-1.05=3.15\,\mathrm{kW}\); for resistance heating it is about 15.67 kW. Electricity used by a circulating pump, external heat leaks or a source below environmental temperature belongs in the appropriate device boundary before drawing a practical comparison. The heat-duty equality ensures that the machines are judged against the same delivered temperature service.

For the resistance case the entropy balance can be checked without using the exergy formula. Electrical work carries no entropy across the control surface, and assume no heat leakage. The stream increases its entropy at \(0.418\ln(333/293)=0.0535\,\mathrm{kW/K}\). Multiplying by the 293 K environment gives 15.7 kW destroyed, consistent with the difference between input work and stream exergy gain. This agreement depends on keeping the heater and heated stream in the same chosen boundary.

Why a real gas cools or warms across a throttle

A gas passes through an insulated porous plug. Its pressure drops and its measured temperature changes. Start with the energy flowing through the plug and obtain a prediction from the equation of state.

Establish which property travels through the plug

A steady control volume with one inlet, one outlet and no shaft work has \(h_1+u_1^2/2+gz_1=h_2+u_2^2/2+gz_2\) when the casing is insulated. Choose the measurement stations in large, level pipes where changes in mean kinetic energy are negligible. Then \(h_1=h_2\). The pressure gradient is sustained by irreversible friction in the plug. Along the family of equilibrium outlet states, a small pressure change produces \(dT=\mu_{JT}dp\), with \(\mu_{JT}=(\partial T/\partial p)_h\). This family lets us compute endpoints without resolving the interior pore flow.

Recover the pressure dependence of enthalpy

Use molar properties. For a simple compressible pure substance, \(dh=T\,ds+v\,dp\). View entropy as a function of \(T,p\). At fixed pressure its temperature derivative is \(c_p/T\). To obtain its pressure derivative, differentiate \(g=h-Ts\). Its differential is \(dg=-s\,dT+v\,dp\). Equality of mixed derivatives gives

\[(\partial s/\partial p)_T=-(\partial v/\partial T)_p.\]

Substitution yields

\[dh=c_p\,dT+\left[v-T\left({\partial v\over\partial T}\right)_p\right]dp,\]
\[\mu_{JT}={T(\partial v/\partial T)_p-v\over c_p}.\]

For an ideal gas \(v=RT/p\) the two numerator terms cancel at all temperatures. Real gas attractions and finite molecular volume affect this near cancellation. Since \(dp<0\) for the pressure drop, positive \(\mu_{JT}\) indicates cooling. Check units by dividing cubic metres per mole by joules per mole per kelvin. The result is kelvins per pascal.

An instructive gas with an inversion temperature

Represent a dilute model gas by \(v=RT/p+B(T)\), with \(B=b-a/(RT)\). Here \(a,b\) are constants and the omitted equation-of-state terms become important at higher density. The ideal part cancels identically. Differentiating the correction gives

\[\mu_{JT}\simeq {T B'(T)-B(T)\over c_p}={2a/(RT)-b\over c_p},\]
\[T_{\rm inv}={2a\over Rb}.\]

With \(b=4.0\times10^{-5}\) m³/mol, \(a=0.080\) Pa m⁶/mol², \(R=8.314\) J/(mol K) and \(c_p=30\) J/(mol K), the inversion lies near 481 K. At 300 K, \(\mu_{JT}=0.0805\) K/bar. A modest drop from 3 bar to 1 bar cools this gas by about 0.161 K. At 600 K the derivative is about −0.0264 K/bar. The same pressure drop then warms the gas by 0.0528 K. Treat this as a local calculation. Over a large temperature range one should integrate the property derivative using a validated equation of state.

Alter the pressure drop while holding the attractive constant fixed. Locate the zero crossing at two pressure drops. Explain why it remains at the same temperature in this first-order calculation and why the cooling magnitudes change.

Tutorial · infer the attractive correction

A low-density gas at 320 K gives a positive slope of 0.060 K/bar in a throttle experiment. Assume the same \(b,c_p\) as above. Estimate a and the inversion temperature. How would an unaccounted heat leak from a warm room bias the inference if the gas cools?

Show the inference and sign check

Convert the slope to \(6.0\times10^{-7}\) K/Pa. Rearranging gives \(a=(RT/2)(c_p\mu_{JT}+b)=0.0772\) Pa m⁶/mol², whence \(T_{\rm inv}=464\) K. A warm leak partially cancels cooling, making the observed outlet temperature drop too small. Because the pressure drop is also negative, the apparent positive slope is smaller. In this parameter fit the estimated a is therefore too low.

Further reading · MIT 2.43 · property relations and the Joule–Thomson coefficient

Finding the vapour fraction of an equilibrium flash

A mixture enters a separator at given overall composition, pressure and temperature. Some components prefer the vapour more strongly than others. Derive a scalar equation for the fraction that evaporates and test for a two-phase solution before iterating.

Connect composition to the equilibrium ratios

Let \(F=L+V\) be the total molar feed and liquid and vapour flow rates. Overall component fractions are \(z_i\), liquid fractions \(x_i\) and vapour fractions \(y_i\). At equilibrium the chemical potential of each species agrees across phases. In an ideal gas over an ideal liquid this reduces to Raoult's law \(y_i p=x_i p_i^{\rm sat}(T)\), so \(K_i=y_i/x_i=p_i^{\rm sat}(T)/p\). A larger K enriches that species in the vapour. For a real mixture K can depend on phase composition and require an outer property iteration. Here use fixed positive K values to isolate the material balance.

Eliminate the component flows

Define \(\beta=V/F\). Component conservation gives

\[z_i=(1-\beta)x_i+\beta y_i=x_i[1+\beta(K_i-1)].\]

Thus \(x_i=z_i/[1+\beta(K_i-1)]\). For both compositions to sum to one, enforce \(\sum_i(y_i-x_i)=0\), giving the Rachford–Rice equation:

\[R(\beta)=\sum_i{z_i(K_i-1)\over1+\beta(K_i-1)}=0,\]
\[R'(\beta)=-\sum_i{z_i(K_i-1)^2\over[1+\beta(K_i-1)]^2}.\]

The denominators are positive for \(0\le\beta\le1\). With at least one non-unity K of positive feed fraction, R decreases strictly, so at most one physical root exists. A positive R(0) and a negative R(1) bracket two phases. If \(R(0)\le0\) the stable fixed-K split is all liquid; if \(R(1)\ge0\) it is all vapour, with equality corresponding to incipient phase appearance. When every K is one this balance cannot specify \(\beta\). A bracketed numerical method preserves the meaningful interval even near a phase boundary.

Perform a binary flash and change the feed composition

Choose \(K_A=2,\ K_B=0.5,\ z_A=z_B=0.5\). Then

\[R(0)=0.25,\ R(1)=-0.25.\]

Multiplying by the two denominators gives \(0.25-0.50\beta=0\), hence \(\beta=0.50\). Liquid fractions are \(x_A=1/3,\ x_B=2/3\), and vapour fractions are

\[y_A=2/3,\ y_B=1/3.\]

For 10 mol/s feed each outlet carries 5 mol/s. The A balance reads \(5(1/3)+5(2/3)=5\) mol/s.

Increase \(z_A\) to 0.60 at the same T, p and K. The physical root becomes \(\beta=0.80\). The phase compositions remain at the same two endpoints; their proportions change to accommodate the new feed. Indeed the overall A fraction is

\[0.20(1/3)+0.80(2/3)=0.60.\]

At \(z_A=0.75\) the feed lies beyond the vapour endpoint. Then R(1) is positive, and searching outside the interval would produce a vapour fraction above unity. Report a single vapour phase instead. An adiabatic flash at unknown temperature would require a further enthalpy balance.

Start from equal feed fractions and increase the fraction of A until the root leaves the physical interval. Predict which pure-phase endpoint is reached. Compare residual signs at both endpoints before interpreting the reported phase.

Tutorial · determine whether an iteration is warranted

At an operating point take \(K_A=3,\ K_B=0.6\). Compute the liquid and vapour A fractions when both phases coexist. For \(z_A=0.30\), calculate \(\beta\). Repeat the phase test for \(z_A=0.10\) and explain why normalized hypothetical phase compositions can hide a failed balance.

Solve phase closure and the lever rule

Vapour closure gives \(3x_A+0.6(1-x_A)=1\), hence \(x_A=1/6\), \(y_A=1/2\). For overall fraction 0.30,

\[\beta=(0.30-1/6)/(1/2-1/6)=0.40.\]

At \(z_A=0.10\),

\[R(0)=0.10(2)+0.90(-0.4)=-0.16.\]

The feed remains liquid. Renormalizing an unphysical trial vapour composition could make it sum to unity while violating the original component and equilibrium equations. Check the physical endpoint signs first.

Further reading · Penn State, PNG 520 · elementary vapour–liquid equilibrium, flash objective function and numerical solution

When does a polar crystal change its preferred state?

Derive stable and unstable dielectric responses from a free-energy landscape. Separate a reversible small-signal capacitance from a switching experiment.

Why one voltage can support several measured polarisations

Some insulating crystals develop a spontaneous electric polarisation as temperature is lowered. The high-temperature phase may be symmetric under inversion so that states with polarisation \(+P\) and \(-P\) are equivalent in zero field. Near a continuous transition, treat one component of polarisation as an order parameter. A local free-energy density compatible with the symmetry is \(f(P)=a(T-T_c)P^2/2+bP^4/4\) with \(a,b>0\). The omitted terms limit how far in temperature or field this truncated expansion is reliable. The positive quartic term keeps the energy bounded when the quadratic coefficient is negative.

For a device whose applied electric field \(E\) is controlled, the appropriate potential in this simple model is \(g(P;E)=f(P)-EP\). The linear term records external work; changing what is held fixed changes the energy to minimise. Differentiation gives the constitutive equation \(E=a(T-T_c)P+bP^3\). An algebraic root is an equilibrium candidate. A stable local response also requires positive second derivative \(a(T-T_c)+3bP^2\). A very accurate rootfinder can return an unstable stationary point if this second test is omitted.

Find the equilibrium branches and their response

Introduce scaled polarisation \(p\), field \(e\) and temperature parameter \(s\) such that \(g=p^4/4+sp^2/2-ep\). Then \(e=p^3+sp\). For \(s>0\), the slope \(3p^2+s\) stays positive. Each field has one stable solution. At \(e=0\), \(p=0\) and the small-signal susceptibility \(dp/de=1/s\) increases when approaching the ideal critical point from above.

For \(s=-1,\ e=0\), stationary values are \(-1,0,+1\). The middle root has curvature −1 and is a local maximum. Each outer root has curvature 2 and is a minimum. The susceptibility about a selected outer state is \(1/2\) in the scaled units. The fact that the two domains can carry opposite zero-field polarisation does not make the harmonic response negative. The mere existence of a negative-slope segment in the cubic constitutive curve is insufficient to infer a stable isolated small-signal device with that differential response.

Derive the limit of a metastable homogeneous state

Imagine preparing the negative-polarisation state at \(s=-1\), then increasing the applied field slowly. A positive field lowers the energy of the positive state. The negative state can persist locally behind a barrier even after it ceases to be the global minimum. A model of perfectly homogeneous evolution without early nucleation follows this metastable branch until the curvature vanishes. Solve \(3p^2-1=0\), choose \(p=-1/\sqrt3\), and insert it into \(e=p^3-p\). The positive limiting field is

\[e=2/(3\sqrt3)\simeq0.3849.\]

At the opposite spinodal the signs reverse.

This is a limit of the particular energy model. Real switching can occur earlier through domain walls, nucleation, defects or thermally activated barrier crossing. Observing a smaller coercive field in a specimen is not evidence that the cubic equation was solved inaccurately. To compare an actual hysteresis loop with a calculation, state the sweep rate, boundary circuit, sample preparation and a dynamical or nucleation model in addition to equilibrium free energy.

Read a landscape rather than tracing an unlabelled loop

Set \(s=-1\). At zero applied field, locate the two equal wells. Increase positive \(e\) gradually and watch the negative well become shallower. The browser locates real stationary points of the cubic, classifies them by curvature and reports their positions. Its plotted potential shows the energy barrier separating basins. Choose \(s>0\) and repeat to see why fitting the same S-shaped hysteresis loop above a continuous transition would be inappropriate.

A below-transition sample can also form spatially varying domains. Adding a positive gradient term \(K(\nabla P)^2/2\) penalises interfaces, while depolarising fields can favour a mixture with reduced net surface charge. This competition sets new length scales absent from the homogeneous model. An electrode measuring total charge can return near-zero mean polarisation from oppositely oriented domains even though each domain is strongly polarised. A local probe and a bulk capacitance measurement therefore constrain different parts of the model.

Turn a capacitance measurement into a consistency test

For a small harmonic voltage imposed about a prepared local minimum, the differential response is \(\delta P/\delta E=1/[a(T-T_c)+3bP^2]\), provided the driving frequency is slow enough for this local variable to respond and the amplitude is small enough to stay in the same well. Add the vacuum and fast polarisation terms when converting to total displacement \(D\). In a parallel-plate geometry capacitance per area then follows from \(\delta D/\delta E\) divided by thickness.

A large-signal charge–voltage measurement crosses different branches and may dissipate work around a loop. The energy per volume over a closed polarisation cycle is \(\oint E\,dP\) with the sign convention for electrical work. A single equilibrium graph of \(f(P)\) returns to its initial state with no prescribed loop area. Measured hysteresis thus carries dynamical information that a polynomial fit to one reversible branch cannot uniquely reconstruct.

Tutorial

For \(s=-4\) in the scaled model, find zero-field minima and the positive homogeneous spinodal field.

Work through the solution

Zero-field minima lie at \(p=\pm2\). The negative spinodal is

\[p=-\sqrt{4/3}=-2/\sqrt3.\]

Substitution gives positive field \(16/(3\sqrt3)\simeq3.08\). The \( |s|^{3/2}\) dependence follows from the cubic.

A Newton solver initialised at \(p=0\) reports exact convergence for \(s=-1,e=0\). What additional observation rejects that result as the prepared stable state?

Work through the solution

Its residual is exactly zero but the curvature \(3p^2+s=-1\) is negative. A small perturbation lowers the potential. Check a measured weak-field slope or the relaxation after a perturbation, and compare the energy of the two minima.

Why can the homogeneous coercive field be much larger than the measured coercive field?

Work through the solution

The calculation removes a local barrier only when a spatially uniform state ceases to exist. A real material can switch by creating a small favourable domain and moving a wall; electrodes and defects can lower the needed activation energy. The relevant material and time scales differ.

Compare material descriptions

Use MIT's ferroelectrics and polarisation material to distinguish a microscopic source of displacement from the macroscopic free-energy model used here.

Moving constraints, boundary work and a changing energy

A pendulum with a reeled string can gain energy while its support force does no virtual work. A bead on a spinning guide can accelerate without gravity. Follow the work done by the apparatus, derive the relation between a reduced energy and laboratory energy, and identify which quantity a measurement tests.

Parameterise the motion of a guide as well as the bead

Let a prescribed moving guide define positions \(\mathbf r(q,t)\). Its relative velocity along the guide is \(\mathbf r_q\dot q\) and its imposed local velocity is \(\mathbf r_t\), where \(t\) is differentiated at fixed coordinate. The kinetic energy \(T=m|\mathbf r_q\dot q+\mathbf r_t|^2/2\) includes a quadratic term in \(\dot q\), a mixed term linear in \(\dot q\), and a term independent of \(\dot q\). Dropping the last two merely because the guide motion is prescribed generally changes the bead equation. A term independent of \(\dot q\) may still depend on its position \(q\).

For \(L=T-V\) define \(p=\partial_{\dot q}L\) and \({\cal E}=p\dot q-L\). Differentiating along a solution of the Euler–Lagrange equation gives \(d{\cal E}/dt=-\partial_tL\) in the absence of extra nonconservative generalised forces. This identity involves the partial time derivative at fixed \(q,\dot q\). The laboratory energy is

\[E_{\rm lab}=m|\dot{\mathbf r}|^2/2+V.\]

Direct substitution gives \({\cal E}=E_{\rm lab}-m\dot{\mathbf r}\cdot\mathbf r_t\) for a single particle and ordinary position potential. Thus a time-independent reduced Lagrangian can conserve a quantity different from the laboratory mechanical energy. Which observer supplies a force, and which independent variables are held fixed, determine the energy being tracked.

Work supplied by a steadily rotating straight slot

A smooth horizontal guide turns about its inner end with prescribed angle \(\varphi=\Omega t\). Let \(r\) be the bead's distance from the pivot. The velocity is \(\dot r\hat r+r\Omega\hat\varphi\), and the reduced Lagrangian is \(m(\dot r^2+\Omega^2r^2)/2\). Its Euler–Lagrange equation is

\[\ddot r=\Omega^2r.\]

With \(r(0)=r_0,\dot r(0)=0\) the solution is \(r_0\cosh\Omega t\) until the bead leaves the slot. In the laboratory no force acts along the radial tangent of the slot, yet radial acceleration in polar coordinates is \(\ddot r-r\Omega^2\), precisely zero. The tangential acceleration \(2\Omega\dot r\) is provided by the slot wall.

The wall reaction \(R_\varphi=2m\Omega\dot r\) exerts a torque \(rR_\varphi\) on the bead. The driving motor balances the opposite reaction on the slot and supplies power \(\Omega rR_\varphi=2m\Omega^2r\dot r\). Differentiating \(E_{\rm lab}=m(\dot r^2+\Omega^2r^2)/2\) and using the radial equation gives the same power. The reduced energy \(m(\dot r^2-\Omega^2r^2)/2\) is constant. Its difference from \(E_{\rm lab}\) equals \(-\Omega L_z\), with \(L_z=mr^2\Omega\). This is a consequence of uniform imposed rotation, not a negative physical rotational kinetic energy.

For \(m=0.10\,{\rm kg}\), \(r_0=0.050\,{\rm m}\) and \(\Omega=4.0\,{\rm rad/s}\), consider \(t=0.25\,{\rm s}\). The radial position is \(77.2\,{\rm mm}\), radial speed \(0.235\,{\rm m/s}\), and wall reaction \(0.188\,{\rm N}\). The motor supplies about \(0.0580\,{\rm W}\) at that instant. Laboratory energy has risen from \(0.00200\,{\rm J}\) to approximately \(0.00752\,{\rm J}\). Measuring only the angular motor speed would miss the incoming mechanical work. The torque on the drive shaft or the changing moment of inertia supplies the other observable required for an energy budget.

A pendulum with prescribed length

Let a point pendulum have length \(l(t)>0\) and angle \(\theta\) from downward vertical. Using \(x=l\sin\theta\), \(y=-l\cos\theta\) gives \(T=m(\dot l^2+l^2\dot\theta^2)/2\) and \(V=-mgl\cos\theta\) for a fixed gravitational datum. The angular Euler–Lagrange equation becomes

\[\frac{d}{dt}(ml^2\dot\theta)=-mgl\sin\theta,\]
\[\ddot\theta+2\frac{\dot l}{l}\dot\theta+\frac{g}{l}\sin\theta=0 .\]

The term proportional to \(\dot l\dot\theta\) comes directly from differentiating angular momentum about the pivot. With increasing length the angular speed at fixed angular momentum decreases; reeling in has the opposite effect. It can look like damping or amplification in the angular equation even with no friction. A mechanical energy balance distinguishes the reversible exchange with a reel from energy lost as heat.

The radial Newton equation, taking outward as positive, is \(m(\ddot l-l\dot\theta^2)=mg\cos\theta-T_{\rm string}\). Hence \(T_{\rm string}=m(g\cos\theta+l\dot\theta^2-\ddot l)\). The tension power on the bob is \(-T_{\rm string}\dot l\). This has the correct sign when a heavy nearly vertical bob is lowered slowly: \(\dot l>0\) and the gravitational potential decreases as the string takes energy out. At the bottom of a swing the tension is larger, so a reel shortening the string there does more positive work per unit length than it would at a turning point. Timing a cyclic length change can pump an oscillation while the guide returns to precisely its initial length.

With \(m=0.50\,{\rm kg}\), \(l=1.0\,{\rm m}\), \(\dot\theta=2.0\,{\rm rad/s}\), and the bob at the bottom, a short interval of constant-rate shortening at \(\dot l=-0.030\,{\rm m/s}\) has tension \(6.91\,{\rm N}\) and delivers \(0.207\,{\rm W}\). When the bob is momentarily at rest at \(30^\circ\), the tension for the same length and zero radial acceleration is \(4.25\,{\rm N}\). Reversing the reel rate there would remove only \(0.127\,{\rm W}\). A complete finite cycle requires integrating the time-varying tensions and checking the acceleration during each reel reversal.

Translate a pivot and separate real forcing from a coordinate choice

For a pivot translating horizontally at prescribed \(X(t)\) and constant string length \(l\), write \(x=X+l\sin\theta\), \(y=-l\cos\theta\). The kinetic energy includes \(ml\dot X\dot\theta\cos\theta\). In the angular Euler–Lagrange equation the terms proportional to \(\dot X\dot\theta\sin\theta\) cancel, leaving \(l\ddot\theta=-g\sin\theta-\ddot X\cos\theta\). A constant pivot velocity therefore does not force the relative angle. Replacing the pivot velocity by its magnitude as a driving force would wrongly violate Galilean invariance. A horizontal pivot acceleration does force the angle; it appears as the opposite inertial acceleration in the translating frame.

For \(|\theta|\ll1\) and \(X=X_0\cos\omega t\), the equation becomes

\[\ddot\theta+\omega_0^2\theta=(X_0\omega^2/l)\cos\omega t,\]
\[\omega_0^2=g/l.\]

At drive frequencies well below \(\omega_0\),

\[\theta\simeq-\ddot X/g.\]

The bob nearly aligns with the effective gravity in the moving frame. Far above \(\omega_0\), the particular solution is approximately \(-X/l\); then the bob's absolute horizontal coordinate \(X+l\theta\) changes little even while the pivot moves. Near resonance the undamped steady particular amplitude is inappropriate, and the initial transient or a physical damping model matters.

Calculate work done by a moving wall in an elastic collision

A particle of mass \(m\) moves along a line and collides elastically with a wall whose prescribed laboratory velocity is \(U\) during the short contact. In the instantaneous wall frame the incoming relative velocity \(v^--U\) reverses, so

\[v^+=2U-v^-.\]

In the laboratory the impulse is \(J=m(v^+-v^-)=2m(U-v^-)\) and the kinetic energy change is \(\Delta K=m[(v^+)^2-(v^-)^2]/2=UJ\). The energy gained by the particle equals wall velocity times the impulse delivered by the wall. A perfectly elastic contact still changes laboratory kinetic energy when the wall moves, since elasticity was defined for the relative normal velocity.

Suppose a particle of mass \(0.20\,{\rm kg}\) moves right at \(3.0\,{\rm m/s}\) into a right wall moving left at \(0.50\,{\rm m/s}\). Its final velocity is \(-4.0\,{\rm m/s}\), and the impulse on the particle is \(-1.40\,{\rm N\,s}\). The particle's kinetic energy rises from \(0.90\) to \(1.60\,{\rm J}\), exactly \(UJ=0.70\,{\rm J}\). The actuator keeping the wall on schedule supplies the energy. When the same wall recedes to the right at \(0.50\,{\rm m/s}\), the outgoing velocity is \(-2.0\,{\rm m/s}\) and kinetic energy falls by \(0.50\,{\rm J}\). The difference is not symmetric under reversal of wall speed at fixed incoming particle velocity, because that reversal also changes the relative approach speed.

Now trap a particle between a fixed wall and a length \(l(t)\) varying slowly compared with the collision period. To leading order a right-wall collision changes the particle's speed by \(-2\dot l\), and such collisions occur about once in \(2l/v\). Hence \(dv/dt\simeq-(v/l)\dot l\), so \(vl\) is approximately constant. The one-dimensional action around a full bounce cycle is

\[J_{\rm act}=(2\pi)^{-1}(2mvl)=mvl/\pi.\]

This elementary wall argument explains the adiabatic action without requiring the smooth-force approximation at the instantaneous collision. If the wall speed varies quickly within a round trip, the collision phases matter and the averaged invariant can fail.

Starting with \(l_0=0.40\,{\rm m}\) and speed \(4.0\,{\rm m/s}\), slow compression to \(0.30\,{\rm m}\) predicts \(v\simeq5.33\,{\rm m/s}\). Its kinetic energy increases by a factor \(16/9\), supplied through the moving boundary. A pressure sensor at the wall measures impulse per time, \(2mv\) times the collision frequency \(v/(2l)\), giving average force \(mv^2/l\) at leading order. Multiplying this force by the inward speed gives the power required by the predicted energy law. An instantaneous compression while the particle is elsewhere would instead change no kinetic energy until a later collision. The final length alone does not determine the energy unless the rate protocol is specified.

Follow a string through a moving boundary in configuration and time

For a vertical moving pivot with height \(Y(t)\), coordinates \(x=l\sin\theta\), \(y=Y-l\cos\theta\) give kinetic energy \(m[\dot Y^2+2l\dot Y\dot\theta\sin\theta+l^2\dot\theta^2]/2\). Derive the angular equation by differentiating \(p_\theta=ml^2\dot\theta+ml\dot Y\sin\theta\). The terms containing \(\dot Y\dot\theta\cos\theta\) cancel as in horizontal translation; the remaining equation is

\[l\ddot\theta=-(g+\ddot Y)\sin\theta.\]

A vertical acceleration changes the restoring coefficient multiplicatively, unlike a horizontal displacement whose small-angle effect is an additive forcing term. The distinction is visible even when the two pivot motions have identical amplitudes and frequencies.

For \(Y=A\cos\Omega t\), the effective gravity oscillates as \(g-A\Omega^2\cos\Omega t\). The perfectly vertical solution remains an exact solution at any drive amplitude. A small deviation need not remain small, because its linear equation has a periodic coefficient. An observed growth of swing from a tiny initial disturbance near twice the natural frequency is a parametric effect. A camera viewing the pivot and bob together can separate relative angle from large imposed vertical displacement. Estimating angular amplitude from absolute bob height alone introduces a component at the drive frequency unrelated to the swing.

At modest drive \(A=1.0\,{\rm mm}\), \(\Omega=20\,{\rm rad/s}\), the pivot acceleration amplitude is \(0.40\,{\rm m/s^2}\), about four percent of gravity. A pendulum of length \(0.10\,{\rm m}\) has small-angle frequency \(9.90\,{\rm rad/s}\), putting this drive near twice its natural frequency despite the small displacement. For an exactly stationary vertical bob relative to the pivot, the string tension is \(m(g+\ddot Y)\) as long as that value is positive. A force measurement thus contains a direct drive-frequency signal even before transverse oscillation develops. Combining an angle sensor with a load cell helps distinguish contact loss from growth of parametric oscillation.

A fast vertical drive can also modify the slow stability of the inverted position. A quantitative treatment requires separating a fast small angular ripple from the slow tilt and averaging its feedback, with the support acceleration and frequency satisfying the relevant ordering. The instantaneous sign of \(g+\ddot Y\) alone is insufficient to establish the stability of the inverted solution. An upright motion that briefly samples a favourable sign each cycle may still drift away over many cycles. Compare initial perturbations at several drive phases and fit the envelope over complete periods before drawing a stability conclusion.

Treat the drive itself as a degree of freedom

A prescribed rotating slot conceals the energy source behind a fixed pattern speed. Replace the motor by a free rotating turntable with moment of inertia \(I_0\), and let its angle \(\varphi\) evolve dynamically. In the horizontal frictionless problem the total kinetic energy is \(m\dot r^2/2+(I_0+mr^2)\dot\varphi^2/2\). The angle is cyclic, so the total angular momentum \(P=(I_0+mr^2)\dot\varphi\) is constant. As the bead moves out, the turntable slows. The radial equation remains \(\ddot r=r\dot\varphi^2\), but its coefficient now decreases according to the total angular momentum instead of remaining externally fixed.

Eliminate \(\dot\varphi\) from the total energy to find

\[E=m\dot r^2/2+P^2/[2(I_0+mr^2)].\]

The reduced radial potential decreases outwards and feeds radial kinetic energy, but the total energy available is finite. Differentiating the potential gives a radial acceleration \(P^2r/(I_0+mr^2)^2\), consistent with the original radial equation. One should not simply insert \(\dot\varphi=P/(I_0+mr^2)\) into the original kinetic Lagrangian before varying \(r\); the correct fixed-momentum Routh reduction subtracts \(P\dot\varphi\), reversing the sign of the eliminated rotational term. The energy and Lagrangian methods agree once their controlled quantities are distinguished.

With \(I_0=0.020\,{\rm kg\,m^2}\), \(m=0.10\,{\rm kg}\), \(r_0=0.10\,{\rm m}\), initial angular speed \(4.0\,{\rm rad/s}\) and zero radial speed, total momentum is \(0.084\,{\rm kg\,m^2/s}\) and energy \(0.168\,{\rm J}\). At \(r=0.30\,{\rm m}\) the rotation rate has fallen to \(0.084/0.029=2.90\,{\rm rad/s}\). The remaining radial kinetic energy is \(0.168-0.084^2/(2\cdot0.029)=0.0463\,{\rm J}\), giving radial speed \(0.962\,{\rm m/s}\). Under a prescribed constant angular speed of four, the radial first integral instead gives \(\dot r=4\sqrt{r^2-r_0^2}=1.13\,{\rm m/s}\) there. The two runs started with identical positions and velocities but have different power connections.

The drive can also be modelled between those limits. Let a servo apply torque \(\tau_{\rm drive}=K_{\rm s}(\Omega_{\rm command}-\dot\varphi)\). Then \(d[(I_0+mr^2)\dot\varphi]/dt=\tau_{\rm drive}\), and the rate of increase of total mechanical energy is \(\tau_{\rm drive}\dot\varphi\). A high control gain with finite response time can approximate the prescribed-speed case over part of a trajectory, yet a rapid radial change can cause a measurable speed sag. Recording shaft torque and speed together tests the drive rather than attributing its lag to a fictitious radial friction on the bead.

Infer drive work from a closed loop of length and measured tension

The reel-pendulum experiment produces synchronised records of string force and length. Over a period in which the length returns to its original value, the work on the bob from the reel is \(-\oint T\,dl\). A graph of tension against length can enclose a signed area although the string force at each instant is perpendicular to the bob's allowed virtual angular displacement. That loop area measures energy transferred by the imposed control. If the bob returns to its full mechanical state and there are no other energy sources, any net positive reel work must go into losses. If only the string length returns, the bob's energy can increase cycle after cycle.

Suppose the reel shortens by \(20\,{\rm mm}\) during a high-tension interval averaging \(7.0\,{\rm N}\), then pays out the same length while the mean tension is \(4.5\,{\rm N}\). The net mechanical work on the bob is \(0.020(7.0-4.5)=0.050\,{\rm J}\) for that cycle. A torque sensor on a reel of changing winding radius must convert torque to tension with the actual instantaneous radius. A force signal delayed relative to the length encoder can create a spurious enclosed area, especially when tension changes rapidly near a turning point. Repeating the measurement slowly with a known hanging calibration weight provides a direct check of polarity and timing.

Derive rapid-pivot stabilisation rather than replacing gravity by its mean

The vertical-pivot equation can be written \(\ddot\theta+[g/l-(A\Omega^2/l)\cos\Omega t]\sin\theta=0\). The time average of the oscillatory coefficient is zero. Nevertheless a high-frequency pivot can alter slow stability because the small fast ripple in \(\theta\) correlates with the fast acceleration. Let \(\theta=\Theta+\xi\), where \(\Theta\) varies little in a drive period and \(\xi\) is small. Keeping the leading rapidly oscillating term gives \(\ddot\xi\simeq(A\Omega^2/l)\sin\Theta\cos\Omega t\), hence \(\xi\simeq-(A/l)\sin\Theta\cos\Omega t\). Its amplitude scales with displacement ratio \(A/l\), so large acceleration and small angular ripple can coexist.

Expand \(\sin(\Theta+\xi)\simeq\sin\Theta+\xi\cos\Theta\), insert the fast solution, and average. Terms linear in the cosine average to zero but the product of ripple and imposed acceleration gives a mean cosine square of one half. To leading order the slow equation is

\[\ddot\Theta+\frac{g}{l}\sin\Theta+\frac{A^2\Omega^2}{2l^2}\sin\Theta\cos\Theta=0.\]

It derives from an effective potential per angular inertia \(U_{\rm eff}/(ml^2)=-(g/l)\cos\Theta+[A^2\Omega^2/(4l^2)]\sin^2\Theta\), up to a constant. Linearising near \(\Theta=\pi+\eta\) gives

\[\ddot\eta+[A^2\Omega^2/(2l^2)-g/l]\eta=0.\]

The inverted state is stable within the averaged approximation if \(A^2\Omega^2>2gl\). The restoring contribution depends on squared pivot speed amplitude. Replacing effective gravity by its simple time average would miss it entirely.

Choose a rigid pendulum arm with \(l=0.20\,{\rm m}\), drive amplitude \(A=0.0040\,{\rm m}\), and \(\Omega=600\,{\rm s^{-1}}\). The small displacement ratio is \(0.020\), the pivot speed amplitude is \(2.4\,{\rm m/s}\), and \(A^2\Omega^2=5.76\,{\rm m^2/s^2}\), above \(2gl=3.92\,{\rm m^2/s^2}\). The predicted slow angular frequency about the inverted state is \(\sqrt{5.76/(2\cdot0.20^2)-9.81/0.20}=4.79\,{\rm s^{-1}}\), far below the drive frequency. A slow ripple of tilt \(0.10\,{\rm rad}\) has a leading drive-frequency micromotion of roughly \(0.0020\,{\rm rad}\). A camera sampling at an unfortunate phase can hide this micromotion or alias it into apparent slow drift.

The rigid arm in this example is essential. An ordinary string cannot push its bob when an averaged upright configuration requires alternating compression and tension throughout a fast cycle. Check the actual instantaneous radial reaction and the physical actuator's ability to deliver the large acceleration. Also check drive-period, arm elasticity and support resonance before identifying an observed stable wobble with the averaged rigid-arm prediction. The leading formula assumes small ripple and a clear separation between \(\Omega\) and all slow angular frequencies; near threshold the slow restoring coefficient is a small difference and higher-order effects or friction become relatively important.

Separate support work from energy in a moving coordinate

Prescribe an accelerating support. Compare the relative response with what a laboratory observer sees and identify how the drive supplies energy.

Distinguish two ways of moving an endpoint in Hamilton's principle

When a constraint itself is explicitly time dependent, the identity \(\delta g=\nabla g\cdot\delta x=0\) describes a virtual change at fixed time on the moving surface. A variational problem may instead allow the endpoint time to change. If a terminal point moves along a prescribed spacetime curve \(q_b(t)\), the endpoint variation includes \(dq_b=\dot q_b\,dt\); it is not an arbitrary tangent displacement at fixed laboratory clock. The boundary term in the on-shell action is \(p\,dq-H\,dt\). Reading these two terms separately tells which physical terminal conditions a derivation has assumed.

For a free particle of mass \(m\) moving in one dimension from the origin at time zero to \(q\) at time \(T\), the extremal action is \(S=m q^2/(2T)\). Its derivatives are \(S_q=mq/T=p\) and \(S_T=-mq^2/(2T^2)=-H\). If the terminal marker moves as \(q_b(T)=uT\), the action of the connecting extremal is \(mu^2T/2\). Its derivative along that endpoint line is \(p u-H=mu^2/2\), exactly the direct derivative. Holding the endpoint position fixed while differentiating instead gives \(-mu^2/2\). Both derivative experiments are legitimate, but the different signs demonstrate why one must state what is fixed.

Can a numerical action fit identify momentum and energy from a single sequence of terminal markers all moving at speed \(u\)?

Work through the solution

Along that one curve it returns the combination \(pu-H\). Separating momentum and energy requires independent endpoint variations in position and time, or another dynamical relation. For the free-particle model the known quadratic Hamiltonian supplies such a relation. For an unknown effective system a single endpoint track can leave different combinations indistinguishable. A grid of nearby fixed-time endpoints estimates \(p\), and a separate grid of terminal times at fixed place estimates \(-H\). This measurement interpretation is the finite-dimensional counterpart of separating virtual reaction work from actual boundary power.

Infer whether a moving wall may be treated as prescribed

In an actual impact apparatus the wall has finite effective mass \(M\). For a one-dimensional elastic impact with an initially moving wall, conservation of total momentum and reversal of relative velocity give

\[v^+=[(m-M)v^-+2MU]/(m+M),\]
\[U^+=[2mv^-+(M-m)U]/(m+M).\]

Only the limit \(M/m\to\infty\), or active feedback able to enforce the schedule on the collision time scale, gives the prescribed-wall expression used earlier. A motor that restores its target speed a second later may still behave as a finite inertia during the collision itself.

Take \(m=0.20\,{\rm kg}\), \(M=2.0\,{\rm kg}\), \(v^-=3.0\,{\rm m/s}\) and \(U=-0.50\,{\rm m/s}\). The finite wall sends the particle back at approximately \(-3.36\,{\rm m/s}\) and recoils to \(+0.136\,{\rm m/s}\), compared with the prescribed-wall prediction of \(-4.0\,{\rm m/s}\). Check that the initial and final total momenta both equal about \(-0.40\,{\rm kg\,m/s}\). Measuring wall speed immediately before and after contact separates an imperfectly enforced boundary from an inelastic impact; both can reduce the magnitude of particle rebound relative to an ideal prescribed boundary.

Tutorial on a prescribed moving apparatus

The rotating slot is held at fixed \(\Omega\), but the bead is initially given inward speed \(-\Omega r_0\). Predict its subsequent motion and whether the motor delivers or receives power.

Work through the solution

The general solution is a combination of growing and decaying exponentials. These initial conditions select \(r=r_0e^{-\Omega t}\). The wall reaction \(2m\Omega\dot r\) is negative, and its power \(2m\Omega^2r\dot r\) is also negative. The motor receives energy from the bead while maintaining its speed. The same geometric constraint can therefore inject or absorb energy depending on the actual trajectory. The origin is approached only asymptotically in the ideal solution.

At \(l=0.80\,{\rm m}\) and \(\theta=0\), a bob has zero angular speed and the prescribed reel tries to accelerate the length outward at \(12\,{\rm m/s^2}\). Can a string enforce this motion?

Work through the solution

The radial-force equation gives \(T=m(g-12)\), a negative tension. A string cannot push the bob outward. The reel pays out slack and the bob initially accelerates under gravity, so treating \(l(t)\) as its exact radius becomes inadmissible. A rigid telescopic arm capable of compression would impose a different physical constraint and could enforce the same geometrical schedule.

A pivot is displaced sinusoidally by \(2.0\,{\rm mm}\) at \(1.0\,{\rm Hz}\) with \(l=0.25\,{\rm m}\). Is the low-frequency tilt formula suitable?

Work through the solution

The natural angular frequency is \(\sqrt{9.81/0.25}=6.26\,{\rm rad/s}\), almost equal to the drive angular frequency \(2\pi=6.28\,{\rm rad/s}\). The low-frequency expansion requires a frequency much smaller than the natural one and fails here. Measure damping and initial conditions, or model a finite-time drive. A steady frictionless amplitude calculated from the small difference of squared frequencies is extremely sensitive to uncertainties in the length and drive frequency.

Compare a second rotating constraint and identify what the motor holds fixed.

David Tong's Lagrangian dynamics chapter develops explicitly time-dependent coordinate changes.

Heat stored in quantum degrees of freedom

Build the single-particle spectrum before taking the thermal average. Compare acoustic branches, magnetic ordering and paired electrons, and trace how a radiometer samples a photon reservoir.

  1. Vibrations of monoatomic and diatomic chains
  2. Filling electronic states and measuring the Fermi surface
  3. Magnetic moments and susceptibility
  4. Exchange, spontaneous magnetisation and critical response
  5. Pairing, excitation gaps and what a spectrum measures
  6. How the same electrons carry heat and charge
  7. Why a polar crystal has two optical phonon frequencies
  8. Exchange and two-particle energies
  9. Density matrices and loss of phase
  10. Thermal radiance, étendue and detector calibration
  11. Why an oscillator can move without its packet spreading
  12. From a Coulomb orbit to the fine-structure multiplet
  13. When a magnetic field changes the quantum numbers of an atom
  14. Two electrons, exchange splitting and the cost of localisation
  15. From a finite pulse to a continuum transition rate
  16. Measure tunnelling from a four-site spectrum

Vibrations of monoatomic and diatomic chains

Derive normal modes from a local force law and identify the physical motion behind the acoustic and optical branches.

From first principles

Turn a local spring law into a phonon dispersion relation

Consider identical atoms of mass \(m\) spaced by \(a\) along a chain. Write \(u_j\) for the displacement from the equilibrium position of atom \(j\). For small changes of bond length, expand the bond energy to second order about its minimum. Its first derivative vanishes and its positive second derivative \(K\) is the measured bond stiffness. The bond on the right pulls with force \(K(u_{j+1}-u_j)\); the left bond contributes \(K(u_{j-1}-u_j)\). Newton’s law gives

\[m\ddot u_j=K(u_{j+1}-2u_j+u_{j-1}) .\]

Translation of a normal mode by one site can change its phase but not its shape. Insert \(u_j=Ue^{i(kja-\omega t)}\), divide by the common amplitude, and simplify:

\[-m\omega^2=K(e^{ika}+e^{-ika}-2)=-4K\sin^2(ka/2),\]
\[\omega=2\sqrt{K/m}\,|\sin(ka/2)|.\]

For wavelengths much larger than \(a\),

\[\sin(ka/2)\simeq ka/2.\]

The slope gives the sound speed \(a\sqrt{K/m}\). At \(k=0\) all atoms move together and no bond stretches, which explains the zero frequency. More than one atom per primitive cell permits internal relative motion even at \(k=0\), the ingredient needed for an optical branch.

Derivation and applications

Count the modes that crowd against a chain’s band edge

Why can a narrow frequency bin near the top of a vibration band contain a substantial share of all modes? Take a monoatomic chain of \(N\) equal masses \(m\) with one longitudinal displacement each. Impose periodic ends and use identical harmonic nearest-neighbour springs of stiffness \(K\) with spacing \(a\). The frequency on the positive half of the first zone rises monotonically to \(\omega_m=2\sqrt{K/m}\). Inverting that branch gives the wavevector bounding the states below a trial frequency,

\[k(\omega)=\frac{2}{a}\arcsin\!\left(\frac{\omega}{\omega_m}\right),\qquad 0\leq\omega\leq\omega_m .\]

Allowed wavevectors are spaced by \(2\pi/(Na)\). Counting the interval of width \(2k(\omega)\) includes both propagation directions. In a large chain the fractional count and its derivative per atom are therefore

\[F(\omega)=\frac{2k(\omega)}{2\pi/(Na)}\frac{1}{N}=\frac{2}{\pi}\arcsin\!\left(\frac{\omega}{\omega_m}\right),\]
\[g(\omega)=\frac{dF}{d\omega}=\frac{2}{\pi\omega_m\sqrt{1-(\omega/\omega_m)^2}}.\]

Here \(g\,d\omega\) is a fraction of the modes. The normalization follows from \(F(\omega_m)=1\), as required by the count of independent displacements. Near the edge the slope of the dispersion tends to zero, so evenly spaced wavevectors map into progressively smaller frequency intervals. This causes an integrable singularity in the continuum density. A finite spectrometer bin always contains a finite count. A measured spectrum can also weight modes differently through a probe’s coupling to atomic motion.

Worked example

Count modes within the upper tenth of the band

For \(N=10{,}000\), the interval between \(0.9\omega_m\) and the upper edge contains \(N[1-(2/\pi)\arcsin(0.9)]\simeq2871\) modes, allowing a mode or two for endpoints. A uniform distribution in frequency would give 1000. A nearly stationary wave packet near the upper edge and a large number of modes per unit frequency have the same origin in the small group velocity.

Second application

Use the spectral median to infer a spring stiffness

An ideal chain with atomic mass \(5.00\times10^{-26}\,\mathrm{kg}\) has half of its longitudinal modes below an ordinary frequency of \(4.00\,\mathrm{THz}\). Setting \(F=1/2\) gives

\[\omega_{1/2}/\omega_m=\sin(\pi/4).\]

The upper frequency is \(5.66\,\mathrm{THz}\), and \(K=m(2\pi f_m)^2/4=15.8\,\mathrm{N/m}\). The frequency ratio is unchanged by conversion to angular frequency, but the final stiffness requires that conversion.

Try it · Chain count

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

From bond extension to a travelling displacement

Let atoms of mass \(m\) on a line be coupled by springs of stiffness \(K\), spaced \(a\) apart. The spring to the right pulls site \(n\) by \(K(u_{n+1}-u_n)\); the left contributes \(K(u_{n-1}-u_n)\). A uniform shift produces no force. Translation symmetry suggests \(u_n=u e^{i(kna-\omega t)}\). Substitution gives

\[\omega^2(k)=\frac{2K}{m}(1-\cos ka)=\frac{4K}{m}\sin^2(ka/2).\]

The sound speed at long wavelength is \(a\sqrt{K/m}\), consistent with a continuum rod whose one-dimensional stiffness is \(Ka\) and whose mass per length is \(m/a\). At \(k=\pi/a\) neighbouring atoms move in opposition and the slope of the dispersion vanishes. A wave packet made of nearby \(k\)'s moves with the group velocity \(d\omega/dk\), which can differ greatly from the phase velocity \(\omega/k\) near the boundary.

Background · Why must one vibration have exactly zero frequency?

Give every atom the same displacement. If the potential energy depends only on separations, no bond changes length and no atom experiences a restoring force. Differentiate the force with respect to this uniform translation. For one displacement direction the resulting row-sum condition on the force constants is

\[\sum_j K_{ij}=0,\]
\[D\,(\sqrt{m_1},\ldots,\sqrt{m_N})^T=0,\]
\[D=M^{-1/2}KM^{-1/2}.\]

With unequal masses the translational eigenvector is uniform in physical displacement, while its mass-weighted components vary. A nonzero frequency at zero wavevector may reveal missing neighbour interactions in a numerical model. A real spring to a substrate also breaks translation symmetry and produces a physical gap. The boundary conditions decide which explanation is plausible.

Introduce an internal coordinate

Place masses \(m,M\) alternately, with spacing \(a/2\) between neighbours and cell period \(a\). Let their displacements in cell \(n\) be \(Ue^{ikna}\) and \(Ve^{ikna}\) times the same time factor. The two force balances contain sums of neighbouring amplitudes. For example the A mass sees B in cell \(n\) and in cell \(n-1\), giving \(m\omega^2 U=2KU-K(1+e^{-ika})V\). Exchanging the masses and conjugating the phase gives the second row. Requiring a nonzero solution yields

\[mM\omega^4-2K(m+M)\omega^2+4K^2\sin^2(ka/2)=0 .\]

There are two nonnegative solutions for \(\omega^2\) per \(k\). With \(N\) cells under periodic boundary conditions this gives \(2N\) longitudinal modes, exactly matching the number of independent displacements. At \(k=0\) the lower branch has \(U=V\) and zero frequency. For the upper branch the centre of mass stays fixed, \(mU+MV=0\), with \(\omega^2=2K(1/m+1/M)\). An electric field can excite some optical modes in polar crystals; the branch name alone does not guarantee optical activity.

A gap and a sound speed answer different questions

At the zone boundary \(1+e^{ika}=0\), so the sublattices decouple. If \(M=4m\), the two edge frequencies are \(\sqrt{K/(2m)}\) and \(\sqrt{2K/m}\), a factor of two apart. When the masses become identical the two folded branches meet, recovering the original monoatomic chain in a doubled cell. An apparent branch boundary created by plotting in a smaller zone need not be a physical frequency gap.

Expand the determinant for small \(k\) on the lower branch. Since \(\omega^2\) scales as \(k^2\), discard the term of order \(k^4\). This gives

\[v_s=a\sqrt{K/[2(m+M)]}.\]

The two springs in a cell act in series for long waves, while both masses contribute to inertia. The sound speed alone determines a stiffness-to-mass ratio; measuring the upper branch supplies independent information about the internal motion.

The acoustic branch rises from zero, the optical branch remains above it, and a frequency interval separates them throughout the zone.
For a four-to-one mass ratio the zone-edge frequencies differ by a factor of two. The shaded interval contains no longitudinal normal mode of the infinite chain.
Try it · Diatomic

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Convert a mode count into thermal predictions

Quantisation assigns a harmonic mode levels \(\hbar\omega(j+1/2)\). The thermal part of its mean energy is \(\hbar\omega/[\exp(\hbar\omega/k_BT)-1]\). Low-temperature excitations thus select long-wavelength acoustic modes while high-frequency optical modes remain scarcely populated. Counting states in a three-dimensional sphere gives a low-frequency density proportional to \(\omega^2\) for linear branches. Rescaling the energy integral by \(\hbar\omega/k_BT\) gives thermal energy proportional to \(T^4\) and heat capacity proportional to \(T^3\). Dimensionality and linear dispersion are essential assumptions behind that power.

Count thermally generated vacancies

A mode calculation for a perfect crystal starts with one atom on every site. Heating a real sample can leave some atoms at a surface or reservoir and some lattice sites empty. How large should that defect population be even at thermal equilibrium? Consider \(N\) equivalent sites and \(n_v\) independent vacancies. At fixed temperature and pressure let \(g_f\) be the Gibbs cost of making one vacancy and transferring its atom to the reservoir. It may contain local vibrational contributions. We count the separate entropy of choosing the missing sites explicitly.

There are \(W=N!/[n_v!(N-n_v)!]\) such arrangements. With \(x=n_v/N\) and macroscopic occupations, Stirling’s formula gives

\[\frac{G-G_0}{N}=xg_f+k_BT\left[x\ln x+(1-x)\ln(1-x)\right].\]

Minimizing with respect to \(x\) gives

\[g_f+k_BT\ln[x/(1-x)]=0.\]

The second derivative is positive. Thus \(x=1/(1+e^{g_f/(k_BT)})\). For positive \(g_f\gg k_BT\) there are few vacancies and \(x\simeq e^{-g_f/(k_BT)}\). Each vacancy costs energy, but at tiny \(x\) the number of possible positions grows fast enough to favour a nonzero population. A finite microscopic specimen can still contain zero vacancies at a given instant.

Take \(g_f=0.800\,\mathrm{eV}\) as constant over the chosen range and \(k_B=8.6173\times10^{-5}\,\mathrm{eV/K}\). At \(900\,\mathrm K\), \(k_BT=0.07756\,\mathrm{eV}\) and \(x=3.31\times10^{-5}\). A region with \(10^{15}\) sites contains an expected \(3.31\times10^{10}\) empty sites. At \(600\,\mathrm K\) the equilibrium fraction drops to \(1.91\times10^{-7}\). Rapid cooling may leave an excess because vacancies must migrate to sinks before the concentration relaxes. The formation free energy in this calculation sets an equilibrium population. A migration barrier would enter the time to attain it.

A light substitution can localize a vibration

An infinite monatomic chain has a continuous vibration band, while a single altered atom can support a vibration spatially concentrated near one site. Let identical springs of stiffness \(K\) connect masses \(m\) on a chain of spacing \(a\), except the central mass at site zero is \(M\). Seek a symmetric localized solution with alternating neighbouring amplitudes \(u_n=A(-q)^{|n|}e^{-i\omega t}\) for \(0<q<1\). Alternation is motivated by the top of the perfect-chain band where adjacent atoms oscillate out of phase. Exponential decay supplies the localization.

At any ordinary site away from the impurity, the equation \(-m\omega^2u_n=K(u_{n+1}+u_{n-1}-2u_n)\) gives

\[m\omega^2=K(2+q+q^{-1}).\]

Since \(q+q^{-1}>2\), this frequency lies above the perfect-chain band edge \(\omega_{\max}=2\sqrt{K/m}\). At site zero both neighbours have displacement \(-q u_0\), giving \(M\omega^2=2K(1+q)\). Eliminating \(\omega\) and cancelling \(1+q\) yields

\[q=\frac{M}{2m-M},\]
\[\omega^2=\frac Km(2+q+q^{-1}).\]

The physical condition \(0<q<1\) requires a lighter central mass \(0<M<m\). A heavy isotope can still scatter travelling waves or produce resonant response within the band. This ansatz predicts no exponentially localized symmetric mode above the band for the heavier substitution. Its absence follows from the admissible decay factor rather than an assumption that a heavy impurity cannot move.

Predict a localized spectral peak

Take host atomic mass \(m=4.00\times10^{-26}\) kg, spring stiffness \(K=40.0\) N/m, lattice spacing \(a=0.300\) nm and impurity \(M=m/2\). The host upper angular frequency is

\[2\sqrt{40.0/(4.00\times10^{-26})}=6.32\times10^{13}\,\mathrm{rad/s}.\]

For the impurity \(q=1/3\), so \(\omega^2=(16/3)K/m\), giving \(\omega=7.30\times10^{13}\) rad/s or \(f=11.6\) THz. The ordinary chain ends near \(10.1\) THz.

The neighbour amplitude is minus one third of the central amplitude, and the second neighbour has plus one ninth. Expressing the absolute envelope as \(e^{-|n|a/\xi}\) gives localization length \(\xi=a/\ln3=0.273\) nm. As \(M\) approaches \(m\) from below, \(q\) approaches one, localization length diverges and the extra frequency merges with the band edge. A finite-chain calculation should therefore vary chain length before claiming that a very weak impurity mode is spatially localized: a box shorter than its decay length cannot separate that broad tail from a standing host mode.

Spatially resolved displacement data can provide two independent estimates of impurity mass. Invert the decay-factor relation to obtain \(M/m=2q/(1+q)\) from neighbouring displacement amplitudes. Separately insert the measured localized frequency and the same host force constant in the central equation of motion. Agreement tests the assumption that the impurity changes only inertia. A substituted atom may also change the two neighbouring springs: in that case the observed frequency and decay factor can no longer be fitted by altering mass alone. This inversion distinguishes an isotope-like substitution from a stronger local bonding perturbation.

A weak second impurity far away perturbs the localized mode only through its exponentially small tail. Bringing two such impurities within a few decay lengths allows the modes to mix and split in frequency, offering another test of their spatial localization.

Filling electronic states and measuring the Fermi surface

Use exclusion and state counting to predict carrier energies, thermal response and the effect of dimensionality.

From first principles

Count the states in a filled Fermi sphere

Take independent spin-one-half electrons in a large cube of volume \(V=L^3\) with periodic boundary conditions. The condition \(e^{ik_xL}=1\) permits \(k_x=2\pi n_x/L\), with the same spacing in the other directions. Thus each allowed wave vector occupies reciprocal volume \((2\pi)^3/V\). For the free-particle energy \(E=\hbar^2k^2/(2m)\), all states below energy \(E\) lie in a sphere. Counting its volume and two spin states gives

\[N(E)=2\frac{V}{(2\pi)^3}\frac{4\pi}{3}\left(\frac{2mE}{\hbar^2}\right)^{3/2}.\]

At zero temperature the exclusion principle fills these single-particle states up to \(E_F\). Writing \(n=N/V\), solve the counting formula at that upper limit:

\[k_F=(3\pi^2n)^{1/3},\]
\[E_F=\frac{\hbar^2}{2m}(3\pi^2 n)^{2/3}.\]

The number of available states in a thin energy shell is the derivative \(D(E)dE\). In three dimensions \(D(E)\propto\sqrt E\) because the shell area grows with \(k^2\) while \(dk/dE\) falls as \(1/k\). This counting assumes an isotropic parabolic band. Additional valleys or a different effective dimension change the result.

Background · Fermi level
\[f(E)=1/[1+\exp((E-\mu)/k_BT)]\]

At equilibrium a one-electron level at the chemical potential has mean occupancy one half per available state. Spin multiplicity enters the number of states separately.

Background · Density of states
\[g(E)=dN_{\rm states}/dE\]

State density and state occupation are independent factors. Their product, integrated over a band, gives the mean particle number.

Derivation and applications

Obtain the pressure of a filled Fermi sea by compressing its states

Even at zero temperature a box of mobile electrons exerts a pressure on its boundaries. Consider \(N\) noninteracting spin-one-half fermions in a three-dimensional volume \(V\), with fixed isotropic mass \(m\) and quadratic energy. Take the bottom of the band as a volume-independent energy reference. Every state below \(E_F\) is occupied once per allowed spin state. Since the density of states including spin has the form \(D(E)=C\sqrt E\), dividing two elementary integrals eliminates the normalization constant,

\[\frac{U}{N}=\frac{\int_0^{E_F} E\,C\sqrt E\,dE}{\int_0^{E_F} C\sqrt E\,dE}=\frac35 E_F .\]

State counting gives

\[E_F=(\hbar^2/2m)(3\pi^2 N/V)^{2/3}.\]

During a uniform compression at fixed \(N\) the upper occupied energy rises. At zero entropy the energy derivative with respect to box volume is the negative pressure, so

\[P=-\left(\frac{\partial U}{\partial V}\right)_N=\frac{2U}{3V}=\frac25 nE_F,\]
\[n=\frac NV .\]

Density appears both explicitly and through \(E_F\). A second volume derivative gives the positive resistance to a small fractional compression,

\[B=-V\left(\frac{\partial P}{\partial V}\right)_N=\frac53P=\frac23 nE_F .\]

Both \(P\) and the bulk modulus \(B\) have units of energy per volume. The factor \(5/3\) distinguishes the change of pressure from pressure itself. An actual solid also has electrostatic and lattice contributions. Extracting the electronic contribution from a measured solid modulus requires information about these other stresses and the volume dependence of the band parameters.

Worked example

Estimate the electronic stiffness of a simple metal

Take \(n=5.00\times10^{28}\,\mathrm{m^{-3}}\) and \(E_F=5.00\,\mathrm{eV}\). With \(1\,\mathrm{eV}=1.602\times10^{-19}\,\mathrm J\), the product \(nE_F\) is \(4.01\times10^{10}\,\mathrm{Pa}\). The pressure contribution is \(16.0\,\mathrm{GPa}\) and the modulus is \(26.7\,\mathrm{GPa}\). A one percent volume decrease would raise this pressure by approximately \(0.267\,\mathrm{GPa}\) in the linear response regime.

Second application

Predict a finite compression without linearizing

Suppose a separate trapped gas starts at pressure \(12.0\,\mathrm{kPa}\) and is compressed slowly to \(0.800\) of its original volume at fixed particle number and negligible entropy. Its pressure becomes

\[12.0(1/0.800)^{5/3}=17.4\,\mathrm{kPa}.\]

Its energy per particle rises by only \((1/0.800)^{2/3}=1.16\) times. The larger pressure ratio also contains the increase in particles per unit volume.

Try it · Fermi pressure

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

Count occupied states at zero temperature

Consider a cubic box of volume \(V\) with periodic boundaries and free electrons of effective model mass \(m\). Allowed wavevectors occupy a volume \((2\pi)^3/V\) per state for each spin. At zero temperature each state below the chemical potential is filled. For \(\epsilon=\hbar^2 k^2/2m\) the filled region is a sphere and each \(k\) has two spin states. Hence

\[N=2\frac{V}{(2\pi)^3}\frac{4\pi k_F^3}{3},\]
\[k_F=(3\pi^2 n)^{1/3},\]
\[E_F=\frac{\hbar^2 k_F^2}{2m}.\]

With \(n=8.5\times10^{28}\) m⁻³ and the free electron mass, \(k_F\) is about \(1.36\times10^{10}\) m⁻¹ and \(E_F\) about 7.0 eV. The corresponding temperature \(E_F/k_B\) is roughly 81,000 K. Ordinary room temperature therefore changes occupation only near the outer surface of this sea in a simple metal. This is a model estimate; anisotropic bands and multiple pockets change its interpretation.

The density of states is a derivative

Replacing \(k_F\) by \(k(E)=\sqrt{2mE}/\hbar\) gives the integrated state count below energy \(E\). Its derivative is

\[D(E)=\frac{V}{2\pi^2}\left(\frac{2m}{\hbar^2}\right)^{3/2}\sqrt E,\]
\[D(E_F)=\frac{3N}{2E_F}.\]

Check dimensions by integrating \(D(E)\,dE\) to recover a count. In two dimensions the occupied area grows as \(k^2\) and the density per energy is constant for a parabolic band. In one dimension the count grows as \(k\) and the density has an integrable \(E^{-1/2}\) singularity at its bottom. A large density of states means many states fit in a narrow energy window. It does not imply a large group velocity: a flat dispersion may create the large density.

OneSimulation · What would a probe see at the last atom?

An open one-dimensional chain with one orbital per atom has standing-wave eigenvectors. Counting their energies gives a spectrum for the complete specimen. An ideal local probe couples to the amplitude on the atom below it. For a probe over site \(j\), broaden each spectral line with a normalised Gaussian \(g_\eta\) of experimental width \(\eta\).

\[\rho_j(E)=\sum_n |\psi_n(j)|^2 g_\eta(E-E_n),\]
\[\int \rho_j(E)\,dE=1.\]

The integral counts one orbital per spin at either site. Near a band edge the standing waves vary slowly and have a small amplitude next to the missing neighbour. Their large bulk density of states can coexist with a weak end signal. The OneSimulation eigensolve uses the same Hamiltonian for both curves. Only the projected site changes.

"""Local spectroscopy at an open chain end and in its interior."""
import matplotlib.pyplot as plt
import numpy as np
from onesim.numerics.linear.matrices.dense_linear_algebra import symmetric_eigensystem

sites = 81
hopping = 1.0  # eV
broadening = 0.09  # eV, standard deviation of the energy resolution
hamiltonian = -hopping * (np.eye(sites, k=1) + np.eye(sites, k=-1))
levels, vectors = symmetric_eigensystem(hamiltonian)
energy = np.linspace(-2.6 * hopping, 2.6 * hopping, 1001)
kernel = np.exp(-0.5 * ((energy[:, None] - levels) / broadening)**2)
kernel /= np.sqrt(2 * np.pi) * broadening
fig, ax = plt.subplots(figsize=(6.6, 3.5), layout="constrained")
for site, label in [(0, "End site"), (sites // 2, "Centre site")]:
    weights = np.abs(vectors[site])**2
    density = kernel @ weights
    assert np.isclose(np.trapezoid(density, energy), 1, atol=1e-6)
    print(f"{label}: local density at zero energy = {density[len(energy)//2]:.3f} /eV")
    ax.plot(energy, density, label=label)
ax.set(xlabel="Energy (eV)", ylabel="Local density per site and spin (1/eV)")
ax.grid(alpha=0.2)
ax.legend()
fig.savefig("condensed-matter.png", dpi=180)
A centre-site spectrum rises near both band edges, while the end-site spectrum is largest near zero energy.
The integrated areas agree. Near zero energy the end site carries about 0.318 states/eV per spin and the centre carries 0.160. A change in probe location redistributes spectral weight.

Try it · Local dos

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Download the Python example

Why only a shell contributes to heat capacity

At finite temperature the occupation is \(f(E)=[1+e^{(E-\mu)/k_BT}]^{-1}\). Heating can promote an electron only into a vacant state. Deep in the filled sea all nearby destinations are occupied. The active shell has width of order \(k_BT\), involving about \(D(E_F)k_BT\) states; the typical energy change is another factor \(k_BT\). Thus the thermal energy increases quadratically and the heat capacity rises linearly with \(T\).

A coefficient follows by expanding the smooth density of states across that shell. At fixed particle number, the relevant excess energy to leading order is \(\int (E-E_F)D(E_F)[f(E)-\Theta(E_F-E)]\,dE\). The filled and empty sides contribute equally to this order. Substituting \(x=|E-E_F|/k_BT\) and using \(\int_0^\infty x/(e^x+1)\,dx=\pi^2/12\) gives

\[C_{\rm el}=(\pi^2/3)D(E_F)k_B^2T.\]

This expansion requires the density to be smooth on the thermal scale; a band edge at the chemical potential needs separate treatment.

Separate two low-temperature contributions

In a three-dimensional simple metal combine \(C_\mathrm{el}=\gamma T\) with the phonon result \(C_\mathrm{ph}=\beta T^3\). Plot \(C/T\) against \(T^2\); the intercept estimates \(\gamma\), and the slope estimates \(\beta\). If two points are \((4,3)\) and \((16,6)\) in K² and mJ mol⁻¹ K⁻², respectively, \(\beta=0.25\) mJ mol⁻¹ K⁻⁴ and \(\gamma=2.0\) mJ mol⁻¹ K⁻². Curvature across the fitted interval would be evidence against this two-term description. To go beyond a free sphere we next retain the periodic potential of the ions.

Count charges and electronic compressibility in two dimensions

A two-dimensional electron layer illustrates how changing available spatial dimensions alters the density of states and an electrical measurement. Assume one parabolic subband \(E=E_c+\hbar^2(k_x^2+k_y^2)/(2m^*)\), spin degeneracy two and no valley degeneracy. A square sample of area \(A\) with periodic boundary conditions supplies one state per spin per reciprocal area \((2\pi)^2/A\). Counting the disk up to \(k_F\) gives areal density \(n_s=k_F^2/(2\pi)\), hence

\[E_F-E_c=\frac{\pi\hbar^2n_s}{m^*},\]
\[D_A(E)=\frac{dn_s}{dE_F}=\frac{m^*}{\pi\hbar^2}\]

above the subband edge at zero temperature. Unlike the square-root density in three dimensions, each occupied parabolic two-dimensional subband contributes a constant step. When an additional subband begins to fill it supplies another step, possibly with different degeneracy or mass. Temperature and disorder broaden the step in a real measurement.

An electrostatic gate must both create a field across the insulating spacer and raise the layer’s chemical potential. For areal capacitance \(C_g'\) of the spacer and increment of sheet charge magnitude \(dQ'=e\,dn_s\), the required voltage is

\[dV=dQ'/C_g'+dE_F/e.\]

The second term defines the quantum capacitance \(C_q'=e^2D_A\). Their inverse capacitances add in series. For a small density of states the electronic contribution measurably lowers the total capacitance even when the geometric dimensions are known precisely.

Measure which capacitance limits a device

Take \(m^*=0.067m_e\) and \(n_s=2.00\times10^{15}\) m⁻². Then \(k_F=\sqrt{2\pi n_s}=1.12\times10^8\) m⁻¹ and \(E_F-E_c=7.15\) meV. At 4 K the thermal scale \(k_BT=0.345\) meV is smaller than this separation, supporting the degenerate estimate. The electronic capacitance per area is \(0.0448\) F/m². For a spacer with \(C_g'=0.0100\) F/m², the measured series value is \((1/0.0100+1/0.0448)^{-1}=0.00818\) F/m².

Over a gate area of \(100\) μm², the predicted capacitance is \(0.818\) pF rather than the purely geometric \(1.00\) pF. Treating that measured value as a change of dielectric thickness would misidentify an electronic effect. In the limit of a very high density of states, the quantum capacitance becomes large and the geometric value is recovered. Near depletion the assumptions of a sharp occupied subband and uniform layer require scrutiny. Comparing capacitance with an independent sheet-density measurement can test whether a low reading reflects depleted electronic states or simply a different insulating spacer.

Using the series result, a small gate swing can be split into two measurable energy changes. A 10.0 mV swing at the stated operating point changes sheet charge magnitude by \(8.18\times10^{-5}\) C/m², or sheet density by \(5.10\times10^{14}\) m⁻². The geometric voltage increment is \(8.18\) mV and the chemical-potential contribution is \(1.82\) mV, corresponding to a Fermi-level shift of 1.82 meV. Their sum recovers the imposed swing. This decomposition assumes the layer remains in the same subband and equilibrates through its electrical contact on the capacitance measurement timescale.

A slow measurement with significant leakage instead mixes capacitance with conductance and can corrupt both estimated voltage contributions.

Count states added by raising the Fermi level

For a parabolic band, states within a radius \(k\) fill a length, area or volume in reciprocal space. Since \(k\) scales as \(\sqrt E\), the integrated count varies as \(E^{d/2}\). Normalise at one energy to compare exponents independently of the sample dimensions.

Count states added by raising the Fermi level. Horizontal axis: Energy above band bottom / reference energy. Vertical axis: Integrated count / count at reference energy. Data follow the figure.
Doubling the Fermi energy raises the count by √2, 2 or 2√2. The local slope gives the density of states. Its behaviour at the band edge is quite different even when the three integrated counts agree at the reference energy.
Try it · State count

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Read values from the plot
Integrated count / count at reference energy at selected values of Energy above band bottom / reference energy.
Energy above band bottom / reference energyOne dimensionTwo dimensionsThree dimensions
0.020.141420.020.0028284
0.567490.753320.567490.4275
1.1151.05591.1151.1773
1.65251.28551.65252.1243
2.21.48322.23.2631

Download all 220 plotted samples (CSV)

Magnetic moments and susceptibility

Derive thermal magnetisation for a two-state moment and distinguish its signature from the response of a filled electronic sea.

From first principles

Obtain the Curie law by counting two magnetic orientations

Take many identical, independent localized moments per volume \(n\), each with component \(+\mu\) or \(-\mu\) along an applied induction \(B\). The magnetic energies are \(-\mu B\) and \(+\mu B\). At temperature \(T\) their probabilities are proportional to their Boltzmann factors. With \(x=\mu B/(k_BT)\), normalize the two weights and subtract their contributions to the mean:

\[Z=e^x+e^{-x},\]
\[\langle m_z\rangle=\mu\frac{e^x-e^{-x}}{e^x+e^{-x}}=\mu\tanh x .\]

Multiply by number density to get magnetization. In weak fields or at high temperatures \(x\ll1\), so the leading term in \(\tanh x\) gives

\[M\simeq\frac{n\mu^2 B}{k_BT},\]
\[\chi=\frac{\partial M}{\partial H}\simeq\frac{\mu_0 n\mu^2}{k_BT}.\]

The susceptibility expression uses a weakly magnetic sample with \(B\simeq\mu_0 H\) and negligible demagnetizing correction. At low temperature and fixed nonzero field both the expansion and the \(1/T\) extrapolation fail. The exact two-state average saturates at \(n\mu\) because no moment can contribute more than \(\mu\). Exchange between neighbours can also invalidate the independent weights.

Derivation and applications

Distinguish the saturation moment from the Curie moment

An ion with angular momentum quantum number \(J\) can have more than two projections on a magnetic field. Consider independent identical ions of number density \(n\) in thermal equilibrium, with isotropic Landé factor \(g\) and negligible splitting at zero field. Label the levels \(m=-J,\ldots,J\) so that their moments along the applied induction \(B\) are \(g\mu_Bm\). Adjacent Zeeman levels are then separated by \(g\mu_B B\). Introduce \(x=g\mu_BB/(k_BT)\). Weighing each level with its Boltzmann factor gives

\[Z=\sum_{m=-J}^{J}e^{mx},\]
\[M=ng\mu_B\,\frac{\partial\ln Z}{\partial x}.\]

In weak fields each zero-field state is almost equally likely. The zeroth-order sum of \(m\) vanishes by symmetry. The next term in the numerator is \(x\sum m^2\), while the denominator is \(2J+1\) to this order. Using the sum of squares of the allowed projections gives

\[\langle m\rangle\simeq x\frac{\sum_{m=-J}^J m^2}{2J+1}=\frac{J(J+1)}{3}x .\]

For a dilute specimen take \(B\simeq\mu_0H\). The dimensionless volume susceptibility is the derivative of \(M\) with respect to magnetic field strength \(H\). In strong fields the highest projection alone survives. These limits identify two different combinations of the microscopic parameters,

\[\chi=\frac{\mu_0 n(g\mu_B)^2J(J+1)}{3k_BT},\]
\[M_{\rm sat}=ng\mu_B J .\]

The Curie-law effective moment is \(g\mu_B\sqrt{J(J+1)}\), whereas the aligned projection is \(g\mu_BJ\). Their ratio approaches one for large \(J\). A susceptibility fit requires \(Jx\ll1\); a saturation measurement requires the opposite tendency and sufficiently weak interactions between moments.

Worked example

Predict the response of dilute spin-one ions

Take \(J=1\), \(g=2.00\),

\[n=1.00\times10^{26}\,\mathrm{m^{-3}},\]
\[T=10.0\,\mathrm K.\]

The aligned magnetization is \(1.85\times10^3\,\mathrm{A/m}\). The Curie formula gives \(\chi=2.09\times10^{-4}\). At \(B=0.100\,\mathrm T\), \(Jx=0.0134\), and the predicted magnetization is only \(\chi B/\mu_0=16.6\,\mathrm{A/m}\), consistent with weak polarization.

Second application

Identify a moment from two calibrated measurements

Suppose independent concentration measurements in another material yield a saturation moment of \(3.00\mu_B\) per ion and an effective Curie moment of \(3.87\mu_B\). The squared ratio is \(1+1/J=(3.87/3.00)^2=1.66\), giving \(J\simeq1.50\). The saturation value then gives \(g\simeq2.00\). Susceptibility alone fixes only a product of the factor \(g\) and the size of the angular momentum.

Try it · Spin magnetisation

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

A moment has an energy as well as a direction

Consider \(N\) independent identical magnetic moments in volume \(V\), each with allowed projection \(\pm\mu\) along a uniform applied induction \(B\). The energies are \(\mp\mu B\); the state aligned with the field has lower energy. For \(\beta=1/(k_BT)\) the one-moment partition function is \(Z_1=2\cosh(\beta\mu B)\). From \(\langle m_z\rangle=k_BT\,\partial_B\ln Z_1\) obtain

\[M=n\mu\tanh(\mu B/k_BT),\]
\[n=N/V .\]

The full curve approaches \(n\mu\) at high field or low temperature. In the weak-field regime \(\mu B\ll k_BT\), expansion of the hyperbolic tangent gives

\[M\simeq n\mu^2 B/(k_BT).\]

Under weak magnetisation and negligible demagnetising corrections use \(B\simeq\mu_0H\); the dimensionless SI susceptibility \(\partial M/\partial H\) is then

\[\chi=\mu_0n\mu^2/(k_BT).\]

Be explicit about differentiating with respect to \(B\) or \(H\), which carry different units.

Work a moment count from two measurements

Suppose a dilute two-state sample exhibits saturation magnetisation \(9.27\times10^3\) A/m and the moments are known to have \(\mu=\mu_B=9.27\times10^{-24}\) J/T. The implied density is \(1.00\times10^{27}\) m⁻³. At 10 K and 1 T the argument \(\mu B/k_BT\) is 0.0672, safely in the linear range for a rough estimate: \(M\simeq622\) A/m. At the same temperature a field of about 14.9 T gives argument one and \(M/M_\mathrm{sat}=0.762\). Fitting a straight line up to that field would underestimate the zero-field slope.

If the moment magnitude is unknown, saturation determines \(n\mu\) and the small-field slope supplies \(n\mu^2\). Taken together they can separate density from moment within this model. A mixture of moment species, orbital contributions or interactions can defeat this two-equation inference. Plotting curves at several temperatures against \(B/T\) tests the independent-moment scaling without needing to know the overall density beforehand.

Compare with itinerant spin response

For a weakly perturbed degenerate metal, the two spin species shift by \(\mp\mu B\). Almost all states below \(E_F\) remain doubly occupied, so only a thin shell at the Fermi surface changes its net spin. At low temperature and nearly constant total density of states \(D_V(E_F)\), the spin imbalance is approximately \(D_V(E_F)\mu B\), giving \(M\simeq\mu^2D_V(E_F)B\). The leading Pauli response is nearly temperature independent, in contrast to the \(1/T\) scaling of independent localised moments. This argument addresses spin susceptibility; orbital diamagnetism also contributes to a real measured susceptibility.

Diagnose a small impurity contribution

If bulk data show a roughly constant offset plus a low-temperature upturn, test a simple additive model \(\chi=\chi_0+C/T\) over a weak-field interval. Plot \(\chi\) against \(1/T\) rather than taking an inverse before subtracting the offset. An upturn can arise from a dilute impurity population even when the host electronic sea dominates heat capacity. If scaling fails systematically, examine interactions between moments; the next chapter shows how cooperative ordering changes the small-field susceptibility.

Cool local moments by adiabatic demagnetization

Independent moments have an entropy that depends on the ratio of magnetic field to temperature. For a two-state moment of magnitude \(\mu\), energies are \(\mp\mu B\). Define \(x=\mu B/(k_BT)\). The one-moment partition function is \(2\cosh x\), average energy is \(-\mu B\tanh x\), and the magnetic entropy follows from \(S=k_B\ln Z+U/T\),

\[\frac{S_{\rm spin}}{Nk_B}=\ln(2\cosh x)-x\tanh x .\]

At zero field for fixed positive temperature the moment has two equiprobable orientations and contributes \(k_B\ln2\). At large \(x\) nearly all moments favour the lower state and the spin entropy tends to zero. If field is increased at fixed temperature, this reduction of spin entropy expels heat to a bath. Now isolate the material and reduce the field quasistatically. In the ideal spin-dominated limit entropy remains fixed, so \(x\) remains fixed and \(T/B\) is constant.

Thermal isolation and sufficiently slow variation are both required. The first prevents external heat from entering, and the second allows internal degrees of freedom to follow equilibrium. Other stores of entropy, particularly lattice vibrations or mobile electrons, participate in an actual specimen. The pure spin scaling can then be modified even when the process as a whole is perfectly adiabatic.

Estimate temperature and cooling capacity

Take \(N=1.00\times10^{21}\) independent moments each of magnitude \(\mu_B\), initially at 2.00 K. Magnetize isothermally from negligible field to 3.00 T, using \(\mu_B/k_B=0.6717\) K/T. The final magnetic parameter is \(x=1.01\), giving spin entropy per particle about \(0.362k_B\) compared with the initial \(0.693k_B\). The heat passed to the bath in that reversible isothermal step is \(T N k_B(0.693-0.362)=9.14\) mJ. Work is supplied by the field source during preparation.

Isolate and reduce field from 3.00 T to 0.300 T. Holding \(x\) fixed predicts

\[T_f=2.00(0.300/3.00)=0.200\,\mathrm{K}.\]

Further field reduction in the ideal noninteracting equations would approach zero temperature. Real moments interact, however, and internal effective fields or ordering lift their near-zero-field degeneracy. Thermal leaks and finite relaxation rates also become increasingly important. A practical test records temperature against field on several ramp rates; dependence on the rate can distinguish irreversible heating from a reproducible correction to the equilibrium entropy model. The final cold sample can absorb only finite heat before its moments become disordered, even if the predicted endpoint temperature is very low.

A second check comes from magnetization along the ideal isolated sweep. Since \(M=N\mu\tanh x\) at fixed volume and \(x\) is conserved, the spin magnetization should stay almost constant while both the external field and the temperature fall. In contrast, an isothermal field decrease reduces \(x\) and magnetization. Measuring temperature alone cannot establish that the sample really followed an isentropic spin path. A simultaneous magnetic reading tests the fixed-population interpretation. Deviations concentrated at the weakest fields can signal interactions between moments rather than a general failure of the high-field entropy estimate.

Exchange, spontaneous magnetisation and critical response

Use a mean-field model and a free-energy expansion to explain how a macroscopic moment can arise in zero applied field.

From first principles

How an interaction permits spontaneous magnetization

Put an Ising spin \(s_i=\pm1\) on each lattice site and use a ferromagnetic bond energy \(-J s_i s_j\) with \(J>0\). If every site has \(z\) neighbours, replacing their actual spins by the common mean \(m=\langle s\rangle\) assigns a trial spin energy \(-s(zJm+\mu B)\). Thermal averaging this two-level problem must reproduce the same mean used to construct the local field:

\[m=\frac{\sum_{s=\pm1}s\, e^{s(zJm+\mu B)/(k_BT)}}{\sum_{s=\pm1}e^{s(zJm+\mu B)/(k_BT)}}=\tanh\!\left(\frac{zJm+\mu B}{k_BT}\right).\]

At zero applied field the right-hand side is odd, so \(m=0\) always solves the equation. To decide when two nearby nonzero solutions appear, compare the slope at the origin with one, then retain the cubic correction. Write \(a=zJ/(k_BT)\):

\[m=am-\tfrac13a^3m^3+\cdots,\]
\[T_c^{\rm MF}=zJ/k_B,\qquad m^2\simeq3(a-1)/a^3 .\]

Just below this mean-field critical temperature either sign of \(m\) is possible even in zero applied field. The approximation replaces correlated neighbours by an average. In short-range one-dimensional systems that omission can even change whether a finite-temperature transition exists.

Derivation and applications

Calculate a correlation length without a mean-field transition

Mean-field theory replaces the neighbours of each spin by a common average. A chain gives a case in which the energy of a local reversal can instead be counted exactly. Take an open chain of Ising spins \(s_i=\pm1\), zero external field, and ferromagnetic nearest-neighbour interaction \(J>0\). The energy is \(-J\sum_i s_is_{i+1}\). Specify the first spin and all bond variables \(b_i=s_i s_{i+1}\). This is a one-to-one description of every configuration. Since the energy is a sum over these independent binary bonds, each bond has weights \(e^{K}\) and \(e^{-K}\), where \(K=J/(k_BT)\).

\[p_{\rm wall}=P(b_i=-1)=\frac{1}{1+e^{2K}},\]
\[\langle b_i\rangle=1-2p_{\rm wall}=\tanh K .\]

A wall costs \(2J\) compared with an aligned bond. To compare two spins separated by \(r\) bonds, multiply the intervening \(b_i\). Every interior spin then occurs twice and drops out. Bond independence makes the average of this product particularly simple,

\[\langle s_i s_{i+r}\rangle=\left\langle\prod_{j=i}^{i+r-1} b_j\right\rangle=(\tanh K)^r .\]

Writing the result as an exponential in the physical separation \(ra\), where \(a\) is the site spacing, gives

\[\xi=-\frac{a}{\ln(\tanh K)},\]
\[\xi\simeq\frac a2 e^{2K}\quad (K\gg1).\]

At low temperature the last expression follows by expanding \(\tanh K\simeq1-2e^{-2K}\). At every positive temperature the probability of a wall remains positive. Thus widely separated spins lose correlation in this short-range one-dimensional model. A finite sample shorter than \(\xi\) can still look ordered during a measurement.

Worked example

Estimate decorrelation over a microscope field

Let \(J/k_B=20.0\,\mathrm K\), \(T=10.0\,\mathrm K\) and \(a=0.400\,\mathrm{nm}\). The wall probability is \(1/(1+e^4)=0.0180\), giving about 18 walls per 1000 bonds on average. The exact correlation length is \(10.9\,\mathrm{nm}\). Across \(20.0\,\mathrm{nm}\), or 50 bonds, the measured spin correlation should be approximately \((\tanh2)^{50}=0.160\).

Second application

Infer exchange from a measured spatial decay

In a different chain the correlation drops to one half over eight bonds at \(T=30.0\,\mathrm K\). Each step has correlation \(2^{-1/8}=0.9170\). Inverting \(K=\tfrac12\ln[(1+\langle b\rangle)/(1-\langle b\rangle)]\) gives

\[J/k_B=47.1\,\mathrm K.\]

A local image counting opposite neighbours should then find a fraction \((1-0.9170)/2=0.0415\), an independent test using adjacent spins.

Try it · Ph ising ring

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

Replace neighbouring moments by their average

An independent moment has zero mean at zero field for any positive temperature. In a ferromagnet aligned neighbours can lower the exchange energy. Consider Ising variables \(s_i=\pm1\) with energy \(-J\sum_{\langle ij\rangle}s_i s_j-\mu B\sum_i s_i\), \(J>0\). Each distinct nearest-neighbour bond is counted once. In a uniform mean-field approximation replace a neighbour's spin by \(m=\langle s\rangle\). For coordination number \(z\), an individual spin then feels an effective energy bias \(zJm+\mu B\). Applying the two-state result to that spin requires self-consistency:

\[m=\tanh[(zJm+\mu B)/(k_BT)] .\]

At \(B=0\), \(m=0\) always solves the equation. The slope of the right-hand side at the origin is \(zJ/(k_BT)\). Above the mean-field transition temperature \(T_c=zJ/k_B\) only the disordered solution exists. Below it two symmetry-related nonzero stable solutions appear. The sign selected in a macroscopic region can depend on a small field and on its history.

Approach the transition from either side

For small field above \(T_c\), expand \(\tanh x\simeq x\). This gives \(m\simeq\mu B/[k_B(T-T_c)]\), a Curie–Weiss susceptibility. A positive intercept of an inverse-susceptibility plot can indicate dominant ferromagnetic exchange over a suitable high-temperature interval. It is not an exact measurement of the true ordering temperature, particularly when fluctuations, geometry or competing interactions matter.

Just below \(T_c\), at zero field, expand through the cubic term. Writing \(t=T_c/T\), the nonzero solution has \(m^2\simeq3(t-1)/t^3\), approaching \(3(T_c-T)/T_c\) sufficiently near the transition. The square-root onset is a mean-field prediction. A finite-temperature transition of this type does not exist for a one-dimensional short-range Ising chain in the thermodynamic limit, despite the same simple self-consistency calculation predicting one. Neglecting the cost and entropy of fluctuations can qualitatively change a prediction.

Interpret the curvature of a free energy

A local free energy even under \(m\mapsto-m\) at zero field may be expanded as \(f=\tfrac12a(T-T_c)m^2+\tfrac14 b m^4-hm\), \(a,b>0\). At \(h=0\), the minima sit at 0 above the transition and at \(m=\pm\sqrt{a(T_c-T)/b}\) below it. A positive second derivative indicates local stability, and the differential response \(dm/dh=1/f''\) grows as the curvature weakens. For \(a(T-T_c)=-1,b=4\) in scaled units, the minima are at \(\pm0.5\), have curvature 2 and are lower than the intervening maximum by 0.0625 in free-energy density units.

From a local moment to a macroscopic measurement

Different regions can select opposite stable magnetisations. Domain walls cost exchange and anisotropy energy, while domain formation can reduce the magnetic field energy outside a specimen. A small measured zero-field net moment can therefore coexist with substantial local order. A static uniform free-energy graph alone cannot predict coercivity: wall pinning, nucleation, defects and measurement times affect a hysteresis loop. Temperature-dependent susceptibility, local probes and field-cycling measurements answer complementary questions about the same ordered sample.

Derive the profile and energy of a domain wall

Two domains magnetized in opposite easy-axis directions can coexist, but rotating the magnetization in between costs exchange and anisotropy energy. Consider a uniaxial ferromagnet with magnetization magnitude fixed and angle \(\theta(x)\) relative to the easy axis varying along one spatial coordinate. Assume a planar 180-degree wall in a geometry where additional magnetostatic costs can be neglected for this profile. With exchange stiffness \(A\) in J/m and anisotropy density \(K\) in J/m³, the wall energy per unit area is

\[\sigma_w=\int_{-\infty}^{\infty}[A(\partial_x\theta)^2+K\sin^2\theta]\,dx .\]

A narrow wall saves anisotropy energy but makes the spatial gradient steep. A broad wall saves exchange energy but places more material away from the preferred axis. Variation gives

\[2A\theta''=2K\sin\theta\cos\theta.\]

Multiply by \(\theta'\) and integrate once. Since both gradient and anisotropy term vanish deep inside either domain, the integration constant is zero, yielding \(A(\theta')^2=K\sin^2\theta\). Exchange and anisotropy costs are locally equal on the minimum-energy profile.

Take increasing \(\theta\) between zero and \(\pi\) and define \(\Delta=\sqrt{A/K}\). Separation gives

\[d\theta/\sin\theta=dx/\Delta.\]

With the wall centred at zero,

\[\tan(\theta/2)=\exp(x/\Delta).\]

Inserting the first integral back into the wall energy and changing variable from \(x\) to \(\theta\) gives

\[\sigma_w=2K\Delta\int_0^\pi\sin\theta\,d\theta=4\sqrt{AK}.\]

The profile has long tails, so a quoted wall width must state its convention; \(\pi\Delta\) is a frequently used slope-based width rather than a sharp boundary.

Compare two anisotropies at fixed exchange stiffness

Use \(A=1.00\times10^{-11}\) J/m and \(K=1.00\times10^5\) J/m³. The scale \(\Delta\) is 10.0 nm and conventional width \(\pi\Delta\) is 31.4 nm. Wall energy is \(4.00\) mJ/m². A planar patch of area \(1.00\) μm² costs \(4.00\times10^{-15}\) J, even though the two far domains have the same zero-field bulk energy.

If a second specimen at the same temperature has four times the anisotropy and the same exchange stiffness, the predicted width halves while the cost per area doubles. The combination of width and energy could therefore independently estimate \(A\) and \(K\), whereas either measurement by itself fixes only a ratio or a product. In the limit \(K\to0\) the preferred axis loses meaning and the wall spreads indefinitely in this model. Finite sample size, magnetostatic fields, boundaries and defects then set spatial scales omitted from the one-dimensional calculation.

One can also express the measured magnetization components explicitly. With the local moment in a fixed rotation plane, the easy-axis component is proportional to \(\cos\theta=-\tanh(x/\Delta)\) and the transverse component to \(\sin\theta=1/\cosh(x/\Delta)\). The easy-axis profile passes smoothly through zero even though the moment magnitude remains fixed throughout the wall. A probe sensitive only to that component might incorrectly interpret the central zero as suppression of ferromagnetism. Measuring a transverse component or a quantity sensitive to the full moment tests the distinction between a rotating order parameter and a vanishing one.

Distinguish a soft magnetic response from a loss of stability

In zero applied field the lowest stabilising even expansion is \(f=a m^2/2+m^4/4\) in these units. Vary the quadratic coefficient through zero. Equilibrium requires both stationarity and positive curvature at a minimum.

Distinguish a soft magnetic response from a loss of stability. Horizontal axis: Scaled magnetisation. Vertical axis: Free-energy density (scaled). Data follow the figure.
For a = −1 the stable minima lie at ±1 with energy density −0.25. At a = 0 the quartic term stabilises a flat minimum. This bulk potential cannot by itself predict the field at which an inhomogeneous sample will reverse its magnetisation.
Try it · Landau potential

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Read values from the plot
Free-energy density (scaled) at selected values of Scaled magnetisation.
Scaled magnetisationQuadratic coefficient -1.0Quadratic coefficient +0.0Quadratic coefficient +0.7
−1.70.643022.0883.0995
−0.85−0.230750.13050.38338
0000
0.85−0.230750.13050.38338
1.70.643022.0883.0995

Download all 341 plotted samples (CSV)

Pairing, excitation gaps and what a spectrum measures

Use a two-component excitation model to predict spectroscopic signatures, then distinguish three physically different gaps encountered across the course.

From first principles

See how pairing opens a spectroscopic gap

Begin with a single normal-state band and let \(\xi\) be its energy measured from the chemical potential. A minimal mean-field model for a uniform paired state mixes an electron amplitude with a hole amplitude through a complex pairing energy \(\Delta\). The two diagonal energies have opposite signs. To find its stationary excitations write the eigenvalue condition:

\[H=\begin{pmatrix}\xi&\Delta\\\Delta^*&-\xi\end{pmatrix},\qquad \det(H-EI)=(\xi-E)(-\xi-E)-|\Delta|^2=0 .\]

It follows that the two branches are \(E_\pm=\pm\sqrt{\xi^2+|\Delta|^2}\). At the former Fermi surface \(\xi=0\), even the cheapest positive excitation costs \(|\Delta|\). To predict a tunnelling spectrum for constant isotropic gap and nearly constant normal density of states, count the normal states mapping into an energy interval \(dE\). The Jacobian from \(\xi=\pm\sqrt{E^2-|\Delta|^2}\) gives the normalized density, with the electron and hole weights combined:

\[\frac{D_s(E)}{D_n(0)}=\frac{|E|}{\sqrt{E^2-|\Delta|^2}}\quad (|E|>|\Delta|).\]

There are no states within the ideal gap at this level of description. Finite temperature, lifetime broadening and instrumental resolution change the measured conductance near its edges. The model assumes a nonzero \(\Delta\); it predicts consequences of pairing without deriving the attractive interaction that supports it.

Derivation and applications

Predict the weights of a particle peak and its partner

A pairing gap determines excitation energies, but a momentum-resolved spectrum also measures how strongly an electron couples to each peak. Consider a clean, uniform superconductor with a real positive gap \(\Delta\), at temperature low enough to neglect thermal broadening. Measure the normal-state energy \(\xi\) at one wavevector from the chemical potential. In the electron and hole basis the positive-energy eigenvector has components \(u,v\). The first row of its eigenvalue equation requires

\[(\xi-E)u+\Delta v=0,\]
\[\frac{v}{u}=\frac{E-\xi}{\Delta},\]
\[E=\sqrt{\xi^2+\Delta^2}.\]

Normalize the vector to unit probability. Since \((E-\xi)(E+\xi)=\Delta^2\), the squared amplitude ratio can be written without subtracting two nearly equal energies. The resulting coherence factors are

\[|u|^2=\frac{1}{1+(E-\xi)/(E+\xi)}=\frac12\left(1+\frac{\xi}{E}\right),\]
\[|v|^2=\frac12\left(1-\frac{\xi}{E}\right).\]

The negative-energy eigenvector is orthogonal to the positive one and consequently has electron weight \(|v|^2\). In the ideal single-particle spectral function at this momentum the two sharp peaks have unit total weight,

\[A(\epsilon)=|u|^2\delta(\epsilon-E)+|v|^2\delta(\epsilon+E),\]
\[\int A(\epsilon)\,d\epsilon=1 .\]

Thus the weights exchange as the wavevector passes through the normal Fermi surface. At \(\xi=0\) the two weights are equal. Well above the surface the positive-energy peak carries almost all the weight. To compare both sides quantitatively an experiment must account for occupation and matrix elements; ordinary photoemission alone samples the occupied side most directly.

Worked example

Resolve a weak partner peak

At a selected momentum let \(\xi=3.00\,\mathrm{meV}\) and \(\Delta=4.00\,\mathrm{meV}\). The spectral energies are \(+5.00\) and \(-5.00\,\mathrm{meV}\), with respective electron weights \(0.800\) and \(0.200\). At a momentum with the opposite \(\xi\) and the same gap the two peak energies stay fixed while their weights reverse. Such a weight exchange tests particle–hole mixing more specifically than the peak separation alone.

Second application

Reconstruct a gap using corrected peak areas

In a different sample the peaks are separated by \(6.00\,\mathrm{meV}\), and corrected electron spectral areas have positive-to-negative ratio \(3:2\). Their normalized weights are \(0.600\) and \(0.400\), so

\[\xi/E=0.200.\]

With \(E=3.00\,\mathrm{meV}\) this gives \(\xi=0.600\,\mathrm{meV}\) and \(\Delta=\sqrt{3.00^2-0.600^2}=2.94\,\mathrm{meV}\). Half the separation overestimates the gap here because the probed momentum lies away from the normal Fermi surface.

Try it · Bcs weights

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

Build excitations on a paired state

For a conventional fully gapped superconductor, a mean-field description mixes particle and hole amplitudes near the Fermi surface. With \(\xi_k=\epsilon_k-\mu\) and gap parameter \(\Delta\), a simplified matrix for a time-reversed pair of states is

\[\begin{pmatrix}\xi_k&\Delta\\\Delta^*&-\xi_k\end{pmatrix}\binom{u_k}{v_k}=E\binom{u_k}{v_k},\qquad E_\pm=\pm\sqrt{\xi_k^2+|\Delta|^2}.\]

A positive-energy quasiparticle has minimum energy \(|\Delta|\) where the normal band crossed the chemical potential. Breaking a pair into two excitations can cost at least \(2|\Delta|\). These are different thresholds, so the probe and transition being discussed must be specified. The matrix displays level repulsion, reminiscent of the nearly free electron calculation, but its basis states and the physical origin of the coupling are different.

Transform a density of states

Suppose the normal-state density is approximately constant over the gap scale and the gap is isotropic. For \(E>|\Delta|\),

\[|\xi|=\sqrt{E^2-|\Delta|^2},\]
\[d|\xi|/dE=E/\sqrt{E^2-|\Delta|^2}.\]

Counting the paired branches relative to the normal-state convention yields \(D_s(E)/D_n=|E|/\sqrt{E^2-|\Delta|^2}\) outside the gap and zero inside in the ideal zero-broadening model. The edge singularity is integrable. States removed from the gap reappear near its edges. Thermal broadening, disorder, nodes or an anisotropic gap can change the measured shape.

A low-temperature tunnel junction with a normal counterelectrode of nearly constant density can use differential conductance as a probe of this spectrum, subject to matrix-element and broadening effects. Peaks at biases \(\pm1.5\) mV suggest \(|\Delta|\simeq1.5\) meV in this geometry. Peak separation on the voltage axis is 3.0 mV. Using the weak-coupling BCS ratio \(2|\Delta(0)|/(k_BT_c)\simeq3.53\) gives \(T_c\simeq9.86\) K. Measure \(T_c\) independently; agreement with this estimate supports the simple model, while deviation calls for closer investigation.

Select a second observation that distinguishes the mechanism

A nearly free electron band gap separates eigenvalues near a zone boundary. For conduction it also matters where the chemical potential sits. A superconducting gap opens at the Fermi surface on entering an ordered state, and has magnetic screening and a characteristic temperature dependence. A photonic stop band instead excludes real propagating wavevectors in a frequency range for the specified periodic optical medium. All three can produce missing spectral weight or reduced transmission. Their energies, frequency units, occupation rules and control parameters differ.

Return to the numerical optical stack with a prediction: making both layers identical closes its first stop band even though the artificial zone boundary remains. For a proposed superconducting gap, repeat the tunnelling and magnetisation measurements as temperature crosses the transition. For an electronic band edge, relate spectroscopy to filling, dispersion and transport. This combination of an analytic limit, a controlled change and an independent observable is what makes an interpretation of a spectrum persuasive.

For continued study, see the MIT lectures on Theory of Solids, including quasiparticles and superconducting electrodynamics.

A single-particle tunnelling spectrum can reveal an excitation gap. A weak junction between two superconductors can also carry a coherent pair current that responds directly to their relative condensate phase. Use the gauge-invariant phase difference \(\varphi\), including the vector-potential line integral across the junction. For a simple tunnel junction in the low-transparency regime, its leading coupling energy is

\[U_J=-E_J\cos\varphi.\]

Its \(2\pi\) periodicity reflects invariance under an integer phase winding and the energy minimum at aligned phase for a conventional junction.

A potential difference \(V\) between the condensates causes their relative phase to advance at \(\dot\varphi=2eV/\hbar\), choosing a consistent orientation of current and voltage. Combining electrical power \(IV\) with the rate of change of junction energy gives \(IV=E_J\sin\varphi\,\dot\varphi\), hence

\[I=I_c\sin\varphi,\]
\[I_c=\frac{2eE_J}{\hbar}.\]

Under a steady subcritical current the phase can remain constant while \(V=0\). At constant nonzero voltage the phase winds and the ideal coherent current oscillates with frequency \(f_J=2e|V|/h\). These two statements distinguish a DC pair current with no terminal voltage from an AC pair response under bias. A real junction includes quasiparticle conduction and capacitance, so its observed total current can contain additional components.

Convert a microwave frequency into a voltage

A junction biased at 5.00 μV has Josephson oscillation frequency \(f_J=(2e/h)V=2.42\) GHz. Illuminate the junction with a stable microwave reference of frequency 10.0 GHz. If its mean phase advance locks to one full winding per reference cycle, then \(\langle\dot\varphi\rangle=2\pi f_{\rm ref}\), requiring mean voltage \(hf_{\rm ref}/(2e)=20.7\) μV. Locking to two windings per cycle gives 41.4 μV. Such voltage steps probe phase dynamics and the charge associated with coherent transfer.

Suppose the same device has measured critical current \(I_c=30.0\) nA at the operating temperature. Its coupling energy is \(\hbar I_c/(2e)=9.87\times10^{-24}\) J, corresponding to \(E_J/k_B=0.715\) K. At a bath temperature of 50 mK thermal energy is appreciably smaller, although phase fluctuations can still depend on capacitance and the surrounding circuit. If either electrode is driven normal, the equilibrium phase-link energy disappears and the ideal supercurrent relation ceases to apply. Observing quantized phase locking and an excitation gap therefore accesses two different signatures of the superconducting state; their characteristic frequencies need not be numerically identical.

The two Josephson relations yield a further calibration test that does not require measuring energy directly. At fixed microwave frequency, the voltage separation of successive locking steps is \(hf_{\rm ref}/(2e)\) independently of junction area in the ideal phase model. Increasing junction area can change total critical current and the visibility or width of current intervals over which locking persists, yet should leave the quantized voltage spacing fixed. Looking at spacing and current width separately distinguishes uncertainty in the reference frequency from a change in the junction coupling or its electromagnetic environment.

Estimate a spectral gap when peaks have finite width

Add a phenomenological lifetime broadening to the isotropic quasiparticle density of states by evaluating \(z/\sqrt{z^2-1}\) at \(z=(E+i\Gamma)/\Delta\) and taking the physical nonnegative real density. Hold the gap itself fixed in all three runs.

Estimate a spectral gap when peaks have finite width. Horizontal axis: Energy / superconducting gap. Vertical axis: Density of states / normal-state value. Data follow the figure.
A broader peak and finite central density are possible even with the same gap parameter. At E = 0 the ratio is γ/√(1+γ²), where γ = Γ/Δ. Inferring the gap from a threshold in conductance also requires the thermal and instrumental resolution.
Try it · Dynes

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Read values from the plot
Density of states / normal-state value at selected values of Energy / superconducting gap.
Energy / superconducting gapBroadening Γ/Δ = 0.025Broadening Γ/Δ = 0.1Broadening Γ/Δ = 0.25
−2.61.08331.08281.0803
−1.31.5621.51961.3617
00.0249920.0995040.24254
1.31.5621.51961.3617
2.61.08331.08281.0803

Download all 481 plotted samples (CSV)

How the same electrons carry heat and charge

A metal with high electrical conductivity often also conducts heat well. The quantitative relation involves an open-circuit measurement, the thermal width of the Fermi surface, and the energy dependence of the states able to carry current.

Weigh the states that can carry a current

Use an isotropic band of quasiparticles with energy \(E\), velocity magnitude \(v(E)\), density of states per volume \(D(E)\) and elastic relaxation time \(\tau(E)\). In a weak electric field or temperature gradient the departure from local equilibrium is proportional to the relaxation time times the applied driving term. For a given transport direction the angular average gives \(\langle v_x^2\rangle=v^2/3\) in three dimensions. Define \(\Sigma(E)=D(E)v(E)^2\tau(E)/3\). Electrical current weights a particle by its charge \(q=-e\), while heat current weights it by \(E-\mu\). Three moments consequently suffice for the two linear responses:

\[K_j=\int\Sigma(E)(E-\mu)^j[-\partial_E f(E)]\,dE,\]
\[j=0,1,2.\]

Let \(\mathcal E\) denote the electric/electrochemical field with any chemical-potential gradient properly included. The resulting currents along one direction are \(j_e=q^2K_0\mathcal E-qK_1\nabla T/T\) and \(j_Q=qK_1\mathcal E-K_2\nabla T/T\). The factor \(E-\mu\) in the thermal drive follows from differentiating the Fermi function with respect to temperature. The repeated first moment is a manifestation of reciprocal coupling of electrical and thermal transport in this zero-field model.

Impose the actual electrical boundary condition

A voltage probe draws negligible charge current. Set \(j_e=0\) to obtain \(\mathcal E=S\nabla T\) with \(S=K_1/(qTK_0)\). Substitute this field into the heat current to get

\[\kappa_e=(K_2-K_1^2/K_0)/T.\]

Under the positive measure \(\Sigma(-f')dE/K_0\), the bracket divided by \(K_0\) is the variance of \(E-\mu\). Hence the open-circuit electronic thermal conductivity is nonnegative. Measuring with zero imposed electric field would retain a thermally driven charge current and a different heat-flow coefficient.

For a degenerate metal with smooth \(\Sigma\), the weight \(-f'\) is a narrow even peak. Replacing \(\Sigma\) by \(\Sigma(\mu)\) gives \(K_1=0\), \(K_0=\Sigma(\mu)\), and \(K_2=(\pi^2/3)(k_BT)^2\Sigma(\mu)\). The dimensionless second moment follows by integrating \(x^2/[4\cosh^2(x/2)]\) over the real axis. With \(\sigma=q^2K_0\),

\[\frac{\kappa_e}{\sigma T}=L_0=\frac{\pi^2k_B^2}{3e^2}=2.44\times10^{-8}\,\mathrm{W\,\Omega/K^2}.\]

At \(T=100\,\mathrm K\), a metal with \(\sigma=2.0\times10^7\,\mathrm{S/m}\) has estimated electronic \(\kappa_e=48.8\,\mathrm{W/(m\,K)}\). A total measured conductivity of 60 would leave about \(11\,\mathrm{W/(m\,K)}\) for other carriers if the assumptions hold. Phonons, inelastic scattering or strong energy dependence may change that inference.

Select a narrow range of transport energies

A model energy filter \(\Sigma\propto\exp[-(x-c)^2/(2w^2)]\), with \(x=(E-\mu)/(k_BT)\), \(c,w\) dimensionless, introduces a tunable departure from this metallic limit. The Seebeck coefficient is \((k_B/q)\langle x\rangle\) and the normalised Lorenz ratio is \(\operatorname{var}(x)/(\pi^2/3)\). A very narrow filter centred above the chemical potential produces strong signed thermopower but little heat transport at zero charge current, because current-carrying particles have almost identical excess energies. Those statements refer to the ratio and thermal moments; the absolute conductivity also depends on the overall transmission.

The experiment integrates these moments numerically and plots their normalised weight against the reference Fermi derivative. Vary \(c\) from positive to negative at fixed width. Predict which observable reverses sign and which is invariant before reading the numerical results.

Tutorial on open-circuit transport

For a fitted transport weight with \(\langle x\rangle=0.50,\ \langle x^2\rangle=2.25\), determine the Seebeck coefficient and \(L/L_0\). Use \(k_B/e=86.17\,\mu\mathrm{V/K}\).

Work through the solution

For electrons \(S=-43.1\,\mu\mathrm{V/K}\). The variance is

\[2.25-0.50^2=2.00.\]

Hence

\[L/L_0=2.00/(\pi^2/3)=0.608.\]

Using the second moment without subtracting the square of the first would represent the wrong electrical boundary condition.

Expand a smooth transport function to first order about \(\mu\). What controls the low-temperature sign of \(S\)?

Work through the solution

The constant term contributes nothing to \(K_1\) by symmetry. The slope gives

\[K_1\simeq\Sigma'(\mu)(\pi^2/3)(k_BT)^2.\]

Dividing by \(qTK_0\) yields

\[S\simeq[\pi^2k_B^2T/(3q)]\partial_E\ln\Sigma|_\mu.\]

For electrons a rising transport function gives negative \(S\) in the stated field convention.

Further reading · ETH Zürich, electronic transport coefficients · University of Pisa, transport integrals and Wiedemann–Franz law.

Why a polar crystal has two optical phonon frequencies

A uniform relative displacement of positive and negative ions creates an electric polarisation. A longitudinal vibration induces a macroscopic restoring field while a transverse displacement has a different electrical boundary condition. An infrared spectrum can reveal both frequencies.

Separate the ionic and electronic contributions

For one infrared-active optical mode let \(u\) be relative displacement per primitive cell, \(M\) the effective reduced mass, \(Z^*\) the effective charge in coulombs, and \(N\) the number of cells per volume. The oscillator equation driven by the macroscopic field is

\[M(\ddot u+\gamma\dot u+\omega_{\rm TO}^2u)=Z^*E.\]

The zero-macroscopic-field stiffness defines the transverse optical frequency in this oscillator model. Bound electronic response at these frequencies supplies a real relative background permittivity \(\epsilon_\infty\). The ionic polarisation is \(P_{\rm ion}=NZ^*u\), so \(D=\epsilon_0\epsilon_\infty E+P_{\rm ion}\).

With time convention \(e^{-i\omega t}\), solving for \(u\) gives

\[\epsilon_r(\omega)=\epsilon_\infty+\frac{S}{\omega_{\rm TO}^2-\omega^2-i\gamma\omega},\]
\[S=\frac{N(Z^*)^2}{\epsilon_0 M}.\]

The signed effective charge appears twice, once as drive and once in the dipole density. Its square therefore sets oscillator strength. At zero frequency the ions can follow the field and \(\epsilon_s=\epsilon_\infty+S/\omega_{\rm TO}^2\). Far above the phonon resonance but below electronic absorption the ionic term is small, making \(\epsilon_\infty\) the observed plateau.

Apply Gauss's law to a longitudinal vibration

Consider a long-wavelength, nonzero wavevector \(\boldsymbol k\) with no external free charge. Gauss's law gives

\[\boldsymbol k\cdot\boldsymbol D=0.\]

For a longitudinal field \(D_L=0\), so the ions create \(E_L=-NZ^*u/(\epsilon_0\epsilon_\infty)\). Substituting this opposing field into the undamped oscillator equation adds a restoring term. Thus

\[\omega_{\rm LO}^2=\omega_{\rm TO}^2+S/\epsilon_\infty,\]
\[\frac{\omega_{\rm LO}^2}{\omega_{\rm TO}^2}=\frac{\epsilon_s}{\epsilon_\infty}.\]

Equivalently the longitudinal collective mode is the zero of the lossless dielectric function. The transverse optical frequency is its pole. For a single isotropic mode this is the Lyddane–Sachs–Teller relation. With several infrared modes, anisotropy, damping or mobile free carriers, assigning one measured peak and one dielectric ratio to a single oscillator needs further justification.

Connect a reflectance band with the two modes

In the lossless limit rewrite \(\epsilon_r=\epsilon_\infty(\omega_{\rm LO}^2-\omega^2)/(\omega_{\rm TO}^2-\omega^2)\). Between the two frequencies this is negative. A transverse electromagnetic wave satisfies \(k^2=\epsilon_r\omega^2/c^2\), so its wavenumber becomes imaginary there in a nonmagnetic lossless crystal. At a planar vacuum boundary a semi-infinite crystal therefore has unit ideal reflectance over this interval. Finite damping makes the refractive index complex and allows absorption, smoothing the edges. The two mode frequencies have been deduced from mechanical response and electric boundary conditions; an electromagnetic wave interacting with the lattice is a coupled phonon–polariton excitation.

For \(f_{\rm TO}=6.0\,\mathrm{THz}\), \(\epsilon_\infty=4\) and \(\epsilon_s=9\), \(f_{\rm LO}=9.0\,\mathrm{THz}\). At 7.5 THz in the lossless limit \(\epsilon_r=4(81-56.25)/(36-56.25)=-4.89\). Below the mode, normal-incidence static-index reflectance is

\[[(\sqrt9-1)/(\sqrt9+1)]^2=0.25.\]

Above the phonon plateau the corresponding background reflectance approaches \(1/9\). The interactive plot evaluates the passive complex refractive index and the exact single-interface reflectance. Change the static permittivity and damping; compare the high-reflection interval with the lossless zero and pole.

Tutorial on recovering mode parameters

Optical data give \(f_{\rm TO}=8.0\) THz and \(f_{\rm LO}=10.0\) THz for a single weakly damped mode. With \(\epsilon_\infty=5.0\), estimate the static permittivity and dielectric increment.

Work through the solution
\[\epsilon_s=5(10/8)^2=7.8125.\]

The increment attributed to the optical mode is

\[7.8125-5=2.8125.\]

Angular and cyclic frequency ratios are equal, although an absolute oscillator strength \(S\) requires angular frequencies in the equation of motion.

At a fixed wavevector a probe sees displacement perpendicular to the wavevector. Why is the longitudinal restoring term absent in the electrostatic argument, and what additional coupling can still occur?

Work through the solution

Its ionic polarisation has \(\boldsymbol k\cdot\boldsymbol P_{\rm ion}=0\), hence it creates no longitudinal bulk bound charge \(-i\boldsymbol k\cdot\boldsymbol P_{\rm ion}\). There is no obligatory depolarising longitudinal field. A transverse propagating electromagnetic field can still drive the infrared-active vibration, as encoded in \(\epsilon_r(\omega)\).

Further reading · MIT solid state physics, optical phonons and dielectric response.

Exchange and two-particle energies

Build allowed two-electron states and calculate how exchange symmetry changes the expectation of a repulsive interaction.

From first principles

Construct the allowed two-electron spatial wave functions

Consider identical electrons prepared from two orthonormal spatial orbitals \(a,b\). A product \(|ab\rangle\) labels which coordinate slot contains which orbital. Exchanging the slots maps it to \(|ba\rangle\); the same exchange squared is the identity, so its eigenvalues are \(\pm1\). Form the normalized eigenvectors

\[\Phi_\pm=(|ab\rangle\pm|ba\rangle)/\sqrt2,\]
\[P_{12}\Phi_\pm=\pm\Phi_\pm .\]

The fermionic exchange postulate applies to the full state. A spatially symmetric pair therefore combines with an antisymmetric spin state, and a spatially antisymmetric pair with symmetric spin. For a symmetric interaction \(W\), expand its expectation in both components. The two diagonal terms coincide and the off-diagonal terms are complex conjugates, so

\[\langle\Phi_\pm|W|\Phi_\pm\rangle=J\pm K,\]
\[J=\langle ab|W|ab\rangle,\]
\[K=\operatorname{Re}\langle ab|W|ba\rangle .\]

The difference of \(2K\) is an interference effect in the two-particle amplitude. It can affect the spin-dependent spectrum even when \(W\) is itself independent of spin. If the orbitals cease to be orthogonal, their two-particle normalization must be recomputed before applying this expectation value.

Derivation and applications

Exchange a pair of particles prepared in overlapping orbitals

The familiar factor of \(1/\sqrt2\) for a two-particle superposition assumes orthogonal one-particle states. Localized orbitals centred near each other can overlap. Let \(a(x),b(x)\) be normalized orbitals and \(S=\langle a|b\rangle\). Temporarily label the two coordinate slots 1 and 2 to evaluate inner products. The overlap of \(|a(1)b(2)\rangle\) with its exchange is the product of two one-particle inner products:

\[\langle ab|ba\rangle=\langle a|b\rangle\langle b|a\rangle=|S|^2 .\]

Symmetrize or antisymmetrize the coordinate wave function and normalize only after including this overlap. For \(|S|<1\) the two allowed candidates are

\[\Psi_\pm(x_1,x_2)=\frac{a(x_1)b(x_2)\pm b(x_1)a(x_2)}{\sqrt{2(1\pm|S|^2)}} .\]

The appropriate spatial symmetry depends on the particles and their spin preparation. To connect the result to a measurable energy, consider a weak one-dimensional short-range interaction modelled by \(W=g\delta(x_1-x_2)\). First-order perturbation theory evaluates the probability density on the coincidence line. With \(D=\int|a(x)|^2|b(x)|^2dx\) it gives

\[\langle W\rangle_+=\frac{2gD}{1+|S|^2},\]
\[\langle W\rangle_-=0.\]

At equal coordinates the two exchanged terms have the same value, so the antisymmetric amplitude cancels exactly. This cancellation applies to an ideal contact interaction. A force with finite range can still sample nonzero amplitude on either side of the coincidence line. In the limit \(|S|=1\) the antisymmetric candidate itself disappears.

Worked example

Estimate the interaction splitting in separate traps

Two localized orbitals have overlap magnitude \(0.500\) and measured density overlap \(D=0.120\,\mathrm{\mu m^{-1}}\). For a weak repulsion \(g=2.00\,\mathrm{meV\,\mu m}\) the symmetric spatial state acquires a shift \(2(2.00)(0.120)/1.25=0.384\) meV. The antisymmetric state has zero first-order contact shift. A distinguishable pair in the unsymmetrized product would give \(gD=0.240\) meV. All estimates assume orbital shapes can be held fixed as the interaction is turned on.

Second application

Put both particles in the same orbital

For two bosons occupying the same normalized orbital, \(S=1\) and \(\Psi_+=a(x_1)a(x_2)\). A box orbital of uniform density over \(L=5.00\) micrometres has \(D=1/L=0.200\,\mathrm{\mu m^{-1}}\). At the same coupling the shift is \(g/L=0.400\) meV. Using the orthogonal-orbital normalization here would double this energy. Two spin-polarized identical fermions cannot prepare this shared-orbital state.

Try it · Exchange contact

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

Exchange acts on the entire state

Two identical particles observed at different locations cannot be assigned enduring physical labels by a measurement of position alone. The operator \(P_{12}\) swaps all coordinates of the two particles, including spin. Since a second swap restores the original state, \(P_{12}^2=1\) and exchange eigenvalues are \(\pm1\). In three dimensions identical electrons are fermions, so their total state is antisymmetric under exchange. For a spin-independent Hamiltonian, spatial and spin factors can often be treated separately while enforcing the required product symmetry.

Take two normalized orthogonal spatial orbitals \(a\) and \(b\). Both products \(a(1)b(2)\) and \(b(1)a(2)\) represent the same occupied orbitals. Their symmetric and antisymmetric combinations are

\[\Phi_\pm=\frac{a(1)b(2)\pm b(1)a(2)}{\sqrt2}.\]

The spin singlet is antisymmetric, requiring \(\Phi_+\) for the spatial part. All three spin triplets are symmetric, requiring \(\Phi_-\). Two electrons can share one spatial orbital in a singlet because they occupy different spin orbitals. In contrast the antisymmetric spatial combination vanishes if one sets \(b=a\). The physical constraint applies to the full one-electron state.

Direct and exchange matrix elements

Suppose \(a,b\) are different eigenstates of a single-particle Hamiltonian with energies \(\epsilon_a,\epsilon_b\). For their two-particle sum both spatial combinations have energy \(\epsilon_a+\epsilon_b\). Now include a weak symmetric interaction \(W(\mathbf r_1,\mathbf r_2)\). Expanding \(\langle\Phi_\pm|W|\Phi_\pm\rangle\) gives two identical diagonal terms and two conjugate off-diagonal terms. Their combination is

\[\langle W\rangle_\pm=J\pm K,\]
\[J=\langle ab|W|ab\rangle,\]
\[K=\mathrm{Re}\langle ab|W|ba\rangle .\]

For the Coulomb interaction \(K\) is nonnegative. The triplet spatial state has suppressed coincidence probability, since \(\Phi_-(\mathbf r,\mathbf r)=0\). A repulsive interaction can therefore cost less in the triplet than in the corresponding singlet. This splitting is produced by interference of exchanged amplitudes in the interaction expectation, even when the interaction does not directly depend on spin.

A measured splitting

For two orbitals suppose the independent-particle energy sum is \(-8.00\) eV, the direct integral is \(1.20\) eV and exchange is \(0.070\) eV. In the fixed-orbital estimate the singlet has energy \(-6.73\) eV and the triplet \(-6.87\) eV. The separation is \(2K=0.140\) eV, corresponding to frequency \(3.39\times10^{13}\) Hz. This energy difference need not produce a strong electric-dipole line between the two states. A spin-independent electric dipole preserves the orthogonality of singlet and triplet spin factors.

Orbitals localized far apart can still have appreciable direct electrostatic interaction because charge densities at different sites interact. The exchange integral also requires orbital overlap at a given coordinate and falls rapidly as overlap is removed. Holding sites apart while monitoring the singlet–triplet splitting can consequently distinguish the exchange contribution from the shared direct energy shift. Strong correlation or substantial orbital rearrangement would require a larger basis than the two fixed configurations used here.

Thermal population measurements require one more factor. With negligible magnetic field the three triplet spin projections share the same energy. At temperature well above the splitting, their combined population can approach three times that of the singlet. To extract an energy splitting from population ratios, include this multiplicity before taking a Boltzmann logarithm.

Interfere two identical bosons at a beam splitter

Exchange symmetry has measurable consequences even when there is no interaction energy. A balanced lossless optical beam splitter mixes two incident spatial modes \(a,b\) into outputs \(c,d\). Choose phases so creation operators transform as \(a^\dagger\to(c^\dagger+d^\dagger)/\sqrt2\) and \(b^\dagger\to(c^\dagger-d^\dagger)/\sqrt2\). The relative sign enforces orthogonality of the two output combinations, as required for a unitary transformation. Prepare one photon in each input with identical spectrum, time profile and polarization.

The input is \(a^\dagger b^\dagger|0\rangle\). Applying the two transformations yields terms for both photons leaving \(c\), both leaving \(d\), or one leaving each output. The two one-per-output terms have opposite signs. Boson creation operators commute, so they cancel exactly:

\[|\psi_{\rm out}\rangle=\frac{(c^\dagger)^2-(d^\dagger)^2}{2}|0\rangle=\frac{|2,0\rangle-|0,2\rangle}{\sqrt2}.\]

The alternatives that cancel are both photons transmitted and both photons reflected into the one-per-output event. Photon number is conserved, but ideally the coincidence probability vanishes. If the photons have orthogonal polarization or arrive at distinguishable times, the corresponding internal states retain information about the alternatives. Their one-per-output probabilities then add to one half. This is a two-particle interference measurement, distinct from ordinary interference fringes in a single detector intensity.

Predict a delay scan for Gaussian wave packets

Let normalized temporal field amplitudes be \(f(t)\) and \(g(t)\) and let their overlap be \(s=\int f^*(t)g(t)\,dt\). Retaining these internal labels while adding the two exchange amplitudes gives coincidence probability \(P_{\rm coin}=(1-|s|^2)/2\) for an ideal balanced splitter with one photon in each input. Choose otherwise identical transform-limited Gaussian pulses whose individual arrival-time intensity distributions have standard deviation \(\sigma_t\). Shifting one by delay \(\tau\) makes \(|s|^2=\exp[-\tau^2/(4\sigma_t^2)]\), obtained by completing the square in the overlap integral.

Take \(\sigma_t=100\) fs. At \(\tau=200\) fs the expected coincidence probability is \((1-e^{-1})/2=0.316\), between zero for perfect overlap and 0.500 for widely separated pulses. For 10,000 incident pairs and ideal detection one expects about 3160 coincidences. At a delay \(2\sigma_t\sqrt{\ln2}=167\) fs the coincidence probability has recovered halfway from its minimum to the distant baseline. The full width between those two half-depth delays is 333 fs. Dark counts, multiple-pair generation or unequal beam-splitter transmission can raise the measured minimum even at zero delay. Recording the far-delay baseline separates overall detector efficiency from the normalized depth of the dip.

It is important here that indistinguishability includes every degree of freedom capable of preserving information about the two input alternatives. Two photons with the same central wavelength and similar arrival times may still have orthogonal polarizations or distinguishable frequency profiles. Including polarization overlap multiplies the temporal overlap by the appropriate inner product for separable polarization and time states. Rotating one linear polarization continuously therefore provides an independent control of coincidence depth, even with the delay held at zero. It can test whether residual coincidences come from distinguishability or from an unequal optical splitting ratio.

Density matrices and loss of phase

Distinguish a coherent superposition from a statistical mixture and reconstruct a dephasing rate from measurements in two bases.

From first principles

Turn a preparation ensemble into a density matrix

Suppose a preparation delivers normalized state \(|\psi_j\rangle\) with classical probability \(w_j\), where the weights sum to one. The Born probabilities for a measurement outcome with projector \(\Pi\) must be averaged over the unrecorded preparation. Use the identity \(\langle\psi_j|\Pi|\psi_j\rangle=\operatorname{Tr}(|\psi_j\rangle\langle\psi_j|\Pi)\) and linearity of the trace:

\[P(\Pi)=\sum_jw_j\langle\psi_j|\Pi|\psi_j\rangle=\operatorname{Tr}(\rho\Pi),\]
\[\rho=\sum_jw_j|\psi_j\rangle\langle\psi_j| .\]

In an energy basis the diagonal entries determine energy populations. To measure coherence, project onto \(|+\rangle=(|0\rangle+|1\rangle)/\sqrt2\). Multiplication and unit trace give

\[P(+)=\tfrac12(\rho_{00}+\rho_{11}+\rho_{01}+\rho_{10})=\tfrac12+\operatorname{Re}\rho_{01}.\]

Thus equal energy populations can correspond either to perfectly coherent superposition or to an incoherent mixture. For unitary individual evolutions \(\rho(t)=U\rho(0)U^\dagger\); random relative phases across the ensemble can suppress the average off-diagonal entry while preserving both populations. Tomography in a further phase-shifted basis accesses the imaginary component.

Background · Density operator
\[\rho=\sum_j p_j|\psi_j\rangle\langle\psi_j|\]

A physical state is positive and has trace one. Different statistical preparations can give identical density operators and measurement predictions.

Derivation and applications

Separate reversible phase dispersion from irreversible decay with an echo

An ensemble of spins can lose average phase coherence even when every individual spin evolves unitarily. Start each spin in an equal-amplitude superposition. In a frame rotating at the reference frequency, assume each spin has a time-independent angular detuning \(\delta\) drawn from a Gaussian with zero mean and standard deviation \(\sigma\). Ignore energy relaxation during the measurement. Under free evolution, the two components accumulate a phase difference \(\delta t\). The normalized transverse coherence is the characteristic function of the detuning distribution:

\[C(t)=\int_{-\infty}^{\infty}\frac{d\delta}{\sqrt{2\pi}\sigma}\exp[-\delta^2/(2\sigma^2)]e^{-i\delta t}.\]

Completing the square in the Gaussian exponent or Fourier transforming the normalized Gaussian gives

\[C_{\rm free}(t)=e^{-\sigma^2t^2/2},\]
\[P_{+x}(t)=\tfrac12[1+\operatorname{Re}C_{\rm free}(t)].\]

Now apply an ideal instantaneous \(\pi\) rotation about \(x\) at time \(\tau\). It exchanges the two levels, reversing the sign of subsequent relative phase accumulation in the toggling frame. An individual spin accumulates \(\delta\tau-\delta(t-\tau)\) before readout at \(t\ge\tau\). Gaussian averaging yields

\[|C_{\rm echo}(t)|=e^{-\sigma^2(2\tau-t)^2/2}.\]

At \(t=2\tau\) the static phase dispersion refocuses for every detuning. A separate independent exponential homogeneous decay factor \(e^{-t/T_2}\) would survive in the echo amplitude. Detunings changing appreciably between the two halves also spoil the cancellation. The echo therefore measures which part of an apparent decay remembers its earlier phase.

Worked example

Predict recovery in a broadened sample

Take \(\sigma/(2\pi)=1.00\) kHz. At \(t=0.500\) ms the unrefocused coherence is \(e^{-\pi^2/2}=0.00719\), so

\[P_{+x}=0.5036.\]

With a \(\pi\) pulse at \(0.250\) ms, the same static ensemble instead has ideal echo magnitude one at \(0.500\) ms. The two experiments distinguish rapid loss of ensemble contrast from loss of the individual phase information.

Second application

Infer a homogeneous decay and a timing tolerance

Suppose echoes at \(2.00\) and \(4.00\) ms have normalized magnitudes \(0.800\) and \(0.640\). Their ratio is \(0.800\), giving \(T_2=-2.00\,\mathrm{ms}/\ln0.800=8.96\) ms. If the readout is displaced by \(0.100\) ms from the true echo, static broadening with the previous \(\sigma\) reduces its contrast by another factor \(e^{-(2\pi\,0.100)^2/2}=0.821\). Timing and homogeneous decay enter separately in this inference.

Try it · Static echo

Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.

Two preparations with identical energy populations

Prepare a two-level system with states \(|0\rangle\) and \(|1\rangle\). One source always prepares \((|0\rangle+|1\rangle)/\sqrt2\). Another prepares \(|0\rangle\) or \(|1\rangle\) at random with equal probability. Measuring in the displayed basis gives identical frequencies for the two sources. After projection onto \(|+\rangle=(|0\rangle+|1\rangle)/\sqrt2\), however, the first source always gives plus and the second gives plus on half the trials. An adequate description must store more than the populations seen in one basis.

Define \(\rho=\sum_jp_j|\psi_j\rangle\langle\psi_j|\) for a preparation ensemble. Probabilities follow from \(P(Q)=\mathrm{Tr}(\rho Q)\) for a projector \(Q\). The trace is one, Hermiticity makes expectation values real and positivity ensures probabilities are nonnegative. The first preparation has all matrix entries equal to \(1/2\). The second has diagonal entries \(1/2\) and off-diagonal entries zero. Although a density matrix can be decomposed into ensembles in multiple ways, every measurement prediction depends only on the matrix itself.

Coherence can be lost to an unobserved system

Consider a pure joint state \((|0\rangle|e_0\rangle+|1\rangle|e_1\rangle)/\sqrt2\) of system and environment. Average over any complete environment basis, equivalently take the partial trace. The system retains equal populations, and its off-diagonal element is \(\rho_{01}=\langle e_1|e_0\rangle/2\). If the environment states become orthogonal, they carry enough information to distinguish the two alternatives and system-only interference disappears. The combined system can still be pure.

A simple dephasing model multiplies off-diagonal elements by \(e^{-t/T_2}\), leaving populations fixed. In a rotating frame that removes the known level splitting, initial plus preparation then gives

\[P_+(t)=\frac{1+e^{-t/T_2}}2,\]
\[\mathrm{Tr}\,\rho^2=\frac{1+e^{-2t/T_2}}2 .\]

The first expression follows by projecting onto plus; the second is the sum of diagonal entries of \(\rho^2\). Purity ranges from one for a pure state to one half for the completely mixed two-level state. Population relaxation would change the diagonal entries too. Measuring both the energy basis and the interference basis helps decide whether the simpler model is adequate.

An interference record

Following a calibrated plus preparation, a measurement in the rotating frame gives \(P_+=0.700\) after 30.0 μs. The contrast is \(2P_+-1=0.400\), giving \(T_2=-30.0/\ln(0.400)=32.7\) μs. The inferred purity is

\[(1+0.400^2)/2=0.580.\]

At 60.0 μs an exponential model gives contrast \(0.160\) and \(P_+=0.580\). A different next value can signal nonexponential noise or a misestimated coherent phase.

A single interference quadrature cannot distinguish reduced visibility from uncompensated precession. To test the rotating frame assumption, vary the final projection phase and fit the full fringe. Its phase reports the coherent rotation; its amplitude reports visibility. Combining this with an energy-basis measurement determines the full Bloch vector and makes the purity estimate meaningful even when populations drift.

Purity estimates from finite counts can also be misleading when each fitted probability is treated independently. The reconstructed Bloch vector must have length at most one for a physical density operator. Longer vectors indicate sampling fluctuations or inconsistent calibrations. Increasing repetitions narrows counting uncertainty, while rotating a known reference state helps diagnose systematic errors among measurement axes.

Energy relaxation places a bound on phase memory

Pure dephasing leaves populations fixed. A two-level system coupled to a cold environment can also lose energy by relaxing from excited state \(|1\rangle\) to ground state \(|0\rangle\). Suppose the probability for an initially excited system to survive time \(t\) is \(s=e^{-t/T_1}\). A simple system–environment evolution sends \(|1,E_0\rangle\) to \(\sqrt s|1,E_0\rangle+\sqrt{1-s}|0,E_1\rangle\) and leaves \(|0,E_0\rangle\) unchanged. The two environment states represent absence or presence of a released excitation and are orthogonal.

For an initial superposition only its unrelaxed excited amplitude shares the original environment state with the ground amplitude. Partial tracing consequently multiplies the off-diagonal system element by \(\sqrt s\), while the excited-state probability is multiplied by \(s\). Additional independent Markovian phase noise can multiply the off-diagonal element by \(e^{-t/T_\phi}\). In a rotating frame the resulting evolution is

\[\rho_{11}(t)=e^{-t/T_1}\rho_{11}(0),\]
\[\rho_{01}(t)=e^{-t/T_2}\rho_{01}(0),\]
\[\frac1{T_2}=\frac1{2T_1}+\frac1{T_\phi}.\]

Thus even a perfectly stable transition frequency cannot make coherence last indefinitely when population relaxes. In this two-level model \(T_2\le2T_1\), with equality if there is no additional pure dephasing. At finite bath temperature upward jumps also occur and populations approach a nonzero equilibrium excitation. A multilevel environment or nonexponential noise can require a different fitting model.

Separate two decay mechanisms using independent preparations

First prepare the excited state and measure population decay; suppose it gives \(T_1=40.0\) μs. Prepare \(|+\rangle\) independently and fit fringe contrast to obtain \(T_2=50.0\) μs. The pure-dephasing rate is \(1/50.0-1/80.0=0.00750\) μs⁻¹, corresponding to \(T_\phi=133\) μs. At \(t=40.0\) μs after plus preparation, the excited population is \(e^{-1}/2=0.184\), and the real coherence in the calibrated rotating frame is

\[e^{-0.8}/2=0.225.\]

Then

\[P_+=1/2+\mathrm{Re}\rho_{01}=0.725.\]

The reconstructed purity is \(\rho_{00}^2+\rho_{11}^2+2|\rho_{01}|^2=0.801\) to rounding. As time grows, coherence vanishes but the cold-bath model returns the system to the pure ground state, so purity ultimately rises back to one. This differs qualitatively from pure dephasing of an initial plus state, whose limiting purity is one half. An independently measured \(T_2>2T_1\) would call for checking the data and assumptions about temperature, state assignment, fit functions and time-dependent noise before assigning an unphysical negative pure-dephasing rate.

The two independent preparations can be checked against a single density matrix at an additional time. Starting in plus, a general measurement along a transverse direction gives a cosine fringe whose offset is one half regardless of the energy populations, while its amplitude measures the transverse coherence. A separate energy-basis measurement supplies the population imbalance. Together they determine the full Bloch-vector length, which should never exceed one. If independently fitted transverse and longitudinal decay curves imply a greater length at some time, the combined fitted model cannot represent a physical quantum state there even if each measured curve looks plausible in isolation.

Checking positivity across the fitted interval also constrains long extrapolations from records that cover only a small fraction of a relaxation time.

Thermal radiance, étendue and detector calibration

A square millimetre of a heated object emits thermal radiation into an entire hemisphere. A detector sees only the rays accepted by its optics and only wavelengths to which it responds. Derive the equilibrium spectrum, follow it through an optical collection system and infer what temperature or emissivity a calibrated reading can actually determine.

Count optical states in a large equilibrium cavity

Take a cubic airless cavity of volume \(V\) in thermal equilibrium at temperature \(T\). For its bulk mode density we can use periodic boundary conditions. Allowed wavevectors are separated by \(2\pi/L\) in each coordinate. Count a spherical shell in wavevector space, divide by the volume per state and include two independent transverse polarisations. Substituting \(k=2\pi\nu/c\) gives

\[g(\nu)d\nu/V=8\pi\nu^2d\nu/c^3.\]

Using standing waves in an ideally reflecting large box gives the same leading volume density when directions and polarisations are counted consistently.

One oscillator mode of frequency \(\nu\) can hold \(m=0,1,2,\ldots\) photons. Its thermal occupation has probabilities proportional to \(e^{-mh\nu/k_BT}\). Summing the geometric series and taking its logarithmic derivative gives

\[\langle m\rangle=1/(e^{h\nu/k_BT}-1).\]

Multiplying by the density of modes and energy per photon gives spectral energy density \(u_\nu\). The zero-point contribution of a harmonic oscillator is not part of the thermal power exchanged between these black surfaces. At low frequency the result approaches an energy \(k_BT\) per mode; extending that classical limit to arbitrarily high frequency would make the integrated power diverge.

An isotropic distribution of energy travelling at speed \(c\) produces a normal flux through a small aperture weighted by the direction cosine. Per unit solid angle its radiance is \(B_\nu=cu_\nu/(4\pi)\). Transform to equal wavelength intervals using \(B_\lambda d\lambda=B_\nu|d\nu|\). The two useful spectral forms are

\[B_\nu=\frac{2h\nu^3}{c^2}\frac1{e^{h\nu/k_BT}-1},\]
\[B_\lambda=\frac{2hc^2}{\lambda^5}\frac1{e^{hc/(\lambda k_BT)}-1}.\]

The wavelength expression has units of watts per square metre per steradian per metre of wavelength. To express it per micrometre multiply by one millionth. At 400 K and 10 micrometres the result is 33.56 W per square metre per steradian per micrometre. At 295 K it is 9.14 in the same units. Equal wavelength and equal frequency bins carry different widths, so their distributions reach their maxima at different converted wavelengths. A spectrum's peak should always name its horizontal variable and spectral-density convention.

Distinguish emitter power from brightness in a chosen direction

For a black surface with angle-independent radiance into its outward hemisphere, integrate \(\cos\theta\,d\Omega\). The result is \(\pi\), not \(2\pi\). The emitted spectral power per unit area is \(\pi B_\lambda\). Integrate over frequency using \(x=h\nu/(k_BT)\). The remaining integral \(\int_0^\infty x^3/(e^x-1)\,dx=\pi^4/15\) follows by expanding \(1/(e^x-1)\) as a sum of exponentials and integrating term by term. This yields Stefan–Boltzmann exitance \(M=\sigma T^4\) and identifies the constant \(\sigma=2\pi^5k_B^4/(15h^3c^2)\).

A black patch of 1.0 square millimetre at 400 K emits about 1.45 mW into its entire outward hemisphere over all wavelengths. The same patch at 295 K emits about 0.429 mW. Replacing one by the other changes all-wavelength hemispherical power by about 1.02 mW. This is not the power a small infrared receiver sees through a narrow filter. The integrated emitter number is valuable for energy conservation, but by itself contains no receiver area, direction, passband or optical transmission.

The surface spectrum of a body in thermal equilibrium has directional spectral emissivity equal to its absorptivity in the corresponding reciprocal optical modes under the usual reciprocal-material conditions. An opaque diffuse grey surface with emissivity \(\epsilon\) in an isotropically illuminated background can be modelled by \(\epsilon B_\lambda(T)+(1-\epsilon)B_\lambda(T_{\rm bg})\). It emits less than a black surface but also reflects background. A shiny object viewed in a warm room may consequently display a radiance temperature nearer the reflected scene than its own physical temperature. Specular surfaces require explicit directional knowledge of that scene.

Derive the geometric acceptance without counting the angle twice

An area element \(dA\) normal to the collection axis emits into \(d\Omega\) at angle \(\theta\) a spectral power \(B_\lambda\cos\theta\,dA\,d\Omega\). For a uniformly filled cone of half-angle \(\alpha\) and a uniform patch of area \(A\), integrating gives \(A\pi\sin^2\alpha\). This is its geometrical throughput in air when there is no vignetting. Optical étendue more generally uses \(n^2dA\cos\theta\,d\Omega\). A lossless passive optical relay in geometrical optics preserves this phase-space measure; correspondingly \(L/n^2\) is conserved along a ray in transparent media under the usual stationary conditions.

A direct lens example makes the restriction tangible. An image relay enlarging a uniformly bright patch by a factor of two in each transverse direction forms an image four times the area. In a lossless paraxial design filling the original pupil, each image point then occupies one quarter the solid angle. A detector covering the whole enlarged image and accepting that cone can receive the original power. Placing a fixed small sensor at the image plane intercepts less area instead. Higher magnification has not created additional radiance, even if it makes a small detail easier to resolve.

For the same 1.0 square millimetre patch seen within ten degrees, the projected acceptance is \(9.47\times10^{-8}\) square metre steradian. A wavelength-independent combined transmission and detector absorption of 0.65 leaves effective acceptance \(6.16\times10^{-8}\) square metre steradian. Integrating the Planck curve from 8 to 12 micrometres gives source and background band radiances 133.74 and 35.43 W per square metre per steradian. Their difference yields only 6.05 microwatts in the receiver. Keeping a single midpoint radiance times four micrometres happens to be fairly close here, but there is no fixed universal midpoint correction across temperatures or filters.

Set source and ambient temperatures equal. The emitted and ambient curves remain finite while the differenced instrument reading vanishes. Increase the cone half-angle from ten to twenty degrees and predict the scale factor \(\sin^2 20^\circ/\sin^2 10^\circ=3.88\). The spectral shape should stay fixed if transmission is separable from angle. If real data shift spectral shape with aperture, inspect filter angle dependence, source nonuniformity and stray light. The integral in the readout is computed on the specified 8–12 micrometre band even though the graph shows wavelengths beyond it.

Convert received power to calibrated voltage or counts

A thermal detector may respond to absorbed power through a temperature rise and an electrical responsivity. A photon-counting detector measures absorbed photons, so its count rate contains a factor \(\lambda/(hc)\) multiplying spectral power before integration. Two receivers with identical geometric acceptance and nominal quantum efficiency can respond differently to a changing source temperature if one output is proportional to energy and the other to photon number. Calibrate the actual electrical transfer and make the time interval explicit for accumulated counts.

For an ideal linear power detector let \(V=V_0+gP\), with offset \(V_0\) and gain \(g\). Two calibrated sources spanning the use range determine both. A black reference port at the same ambient temperature can also reject a common background in a chopped measurement. A filter, window or warm lens that absorbs thermal radiation also emits it. If these optics remain unchanged and stable, part of their own emission cancels in a reference difference. A reference traversing a different path generally leaves a residual input that is not captured by an electronic dark measurement.

Suppose effective source-minus-ambient powers of 2.00 and 8.00 microwatts yield 0.120 and 0.420 V. The fitted slope is 0.0500 V per microwatt with an offset of 0.020 V. A reading of 0.320 V implies 6.00 microwatts after offset correction. Substituting the same reading directly into a single-point gain with zero assumed offset would bias the inferred temperature. Rechecking a third reference near six microwatts tests linearity, while repeated zero-input readings at realistic instrument temperature test offset drift.

Invert the radiance and propagate uncertainties

A narrowband blackbody radiance measurement can be inverted analytically by solving Planck's expression for \(T\). In a broad passband use numerical quadrature across the calibrated spectral response and solve a scalar monotone equation when emissivity and background are known. The derivative at a single wavelength is particularly informative for estimating precision. With \(x=hc/(\lambda k_BT)\),

\[\frac{\partial\log B_\lambda}{\partial\log T}=\frac{x}{1-e^{-x}},\]
\[T=\frac{hc/(\lambda k_B)}{\log[1+2hc^2/(\lambda^5B_\lambda)]}.\]

At 10 micrometres and 400 K the logarithmic sensitivity is 3.70. A one-percent relative radiance uncertainty therefore gives about 1.08 K temperature uncertainty if all other quantities are exact. An unknown five-percent emissivity error can dominate that estimate. A two-colour temperature ratio may reduce uncertainty from an emissivity that is constant across the two narrow bands, but cannot cancel an arbitrary spectral emissivity or a large reflected ambient component.

As an example consider a grey object at 400 K and ambient 295 K with emissivity 0.70. At ten micrometres its outgoing radiance is \(0.70(33.56)+0.30(9.14)=26.24\) in the earlier spectral units. Inverting as a perfect blackbody gives a brightness temperature of about 375 K. The difference is a physical radiance–temperature degeneracy. Repeat at known ambient temperatures while keeping the object thermally stabilised to constrain the reflected fraction. If heating the background changes the actual object temperature, a second independent temperature sensor or a transient thermal model is necessary.

When detector heat capacity sets the measured signal

Consider a thermal receiver of heat capacity \(C_d\) coupled to its surroundings with thermal conductance \(G_d\). For small excursions its temperature obeys \(C_d\dot\theta+G_d\theta=P_{\rm abs}(t)\), where \(\theta\) is the excess above its operating point. A voltage thermometer with responsivity \(r_T\) converts this into output. Its frequency-dependent power responsivity is \(r_T/(G_d-i\omega C_d)\). The geometric and spectral calculations determine absorbed optical power, while this thermal equation determines how much of its modulation appears at the electrical output.

Take \(C_d=2.0\) microjoules per kelvin and \(G_d=0.10\) milliwatt per kelvin. The thermal time constant is 20 ms and ordinary corner frequency is 7.96 Hz. A sinusoidal absorbed-power amplitude of 6.0 microwatts would give a static temperature rise of 0.060 K. At 20 Hz the amplitude is reduced by \(1/\sqrt{1+(2\pi f\tau)^2}=0.370\), leaving about 22.2 mK with a phase lag magnitude near 68 degrees. A receiver calibrated with a steady optical power is not automatically calibrated for this chopped experiment.

A square-wave chopper also changes the relation between time-domain peak differences and a lock-in's fundamental reading. For equal hot and reference dwell times, a square wave switching between powers \(P_1,P_0\) has fundamental sinusoidal peak amplitude \(2(P_1-P_0)/\pi\), with different factors for rms and peak reports. The thermal transfer attenuates this component at the chopper frequency and the odd harmonics at their respective frequencies. Substituting the full hot-minus-reference power directly into the first-harmonic response would overestimate the expected signal.

Measure a frequency sweep on a stable reference and test whether amplitude and phase share a single time constant. A geometrical error rescales the amplitude but ordinarily leaves this thermal phase unchanged. A second thermal mass or an electronic filter can introduce another pole. Lowering chop frequency increases thermal signal until the static limit but can expose low-frequency environmental drift. Choose the frequency by comparing the calibrated response with the measured noise spectrum.

Finally, a reference and an unknown source must illuminate the same active area if responsivity varies across the receiver. Imaging one source as a small spot and the other as a filled patch can create a calibration bias even when total spectral powers agree. Translating a reference spot across the detector or imaging the same aperture successively at both temperatures tests that spatial uniformity assumption.

If the sensor is used on a source much smaller than the calibrated reference aperture, record an image or a field-stop scan to determine its filling fraction. Otherwise even exact knowledge of filter transmission and thermodynamic temperature leaves an unknown geometrical scale factor. Aperture filling is part of the measurement equation, not an electronic gain setting.

Tutorial · Infer emissivity using two controlled backgrounds

An opaque diffuse sample at fixed temperature is observed at 10 micrometres against two isotropic backgrounds with calibrated spectral radiances 8.00 and 16.00 W per square metre per steradian per micrometre. The resulting outgoing readings are 25.00 and 27.00 in the same units. Infer emissivity and the sample's blackbody-equivalent radiance. Estimate the significance of independent reading errors of 0.10 units.

Separate the reflected and emitted contributions

The increased outgoing radiance is 2.00 for an 8.00 increase of background. Thus reflectivity is 0.250 and emissivity 0.750. The first measurement gives intrinsic blackbody radiance \([25.00-0.25(8.00)]/0.75=30.67\). The second returns the same value. With 0.10 independent uncertainty on each outgoing reading and exact backgrounds, the slope uncertainty is \(\sqrt2(0.10)/8=0.0177\), as is the absolute emissivity uncertainty. Larger background separation can improve this slope estimate if sample temperature stays fixed.

If the sample transmits radiation, the residual fraction does not all correspond to reflection. A controlled change behind the sample helps detect that additional path. A directional specular reflector exposed to a warm enclosure also does not necessarily see the same angular average used in the diffuse model. Without these checks, a formally precise fitted emissivity can describe the experimental surroundings instead of the material.

Tutorial · Design a numerical spectral-integration check

An engineer tabulates spectral radiance per micrometre on a wavelength mesh. Another rewrites the detector model on an equally spaced frequency mesh, obtaining a signal that differs by several percent after independent mesh refinement. Explain what must transform, what stays dimensionless and how to compare a photon-counting channel with a power channel.

Transform the complete measurement integral

The differential power \(B_\lambda\,d\lambda\) must equal \(B_\nu\,|d\nu|\), with \(|d\lambda/d\nu|=c/\nu^2\). A dimensionless transmission curve becomes the same physical transmission at \(\lambda=c/\nu\); it acquires no additional Jacobian. The integration bounds reverse when increasing wavelength is replaced by increasing frequency. A response specified per unit wavelength, or a calibrated gain integrating a particular finite bin, must instead be interpreted from how it was defined.

Evaluate a unit-transmission test using a very narrow band, then the full 8–12 micrometre band whose radiance values are given above. Refine each grid independently, treating sharp filter edges consistently and converting per-micrometre densities before using metres. For a photon counter divide each spectral power contribution by photon energy before summation. Replacing that energy by a single central-wavelength value is an approximation that should be checked against the full band and source temperature. Close agreement between two different meshes using the same incorrect density is not a valid units check.

NIST radiance-temperature calibrations · spectral radiance, sources and uncertainty

Why an oscillator can move without its packet spreading

Start with the measured mass and curvature of a potential. Factor its Hamiltonian, prove the energy ladder, construct a freely moving Gaussian from number states and find when squeezing or anharmonicity changes that prediction.

Use the equilibrium length and momentum scales

Near a stable minimum a smooth one-dimensional potential has expansion \(V(x)=V(0)+m\omega^2x^2/2+O(x^3)\) after the origin is shifted to the minimum. Choose the arbitrary zero \(V(0)=0\). The fitted curvature is \(m\omega^2\), not \(\omega\) itself; measuring both the oscillation frequency and restoring slope separately identifies the effective mass. The classical energy ellipse becomes a circle if position and momentum are rescaled consistently. Define \(X=\sqrt{m\omega/\hbar}\,x\) and \(P=p/\sqrt{m\hbar\omega}\), so \([X,P]=i\) and \(H=\hbar\omega(X^2+P^2)/2\). Since position and momentum fail to commute, multiplying two linear factors must retain their order.

Set \(a=(X+iP)/\sqrt2\) and \(a^\dagger=(X-iP)/\sqrt2\). Then

\[a^\dagger a=(X^2+P^2+i[X,P])/2=(X^2+P^2-1)/2.\]

Thus \(H=\hbar\omega(N+1/2)\), \(N=a^\dagger a\) and \([a,a^\dagger]=1\). For every normalised state in the relevant domain \(\langle N\rangle=\|a|\psi\rangle\|^2\ge0\). The additive half quantum is an energy contribution that survives in a state with vanishing classical means of \(x,p\); discarding the commutator would lose it. Transition frequencies within an ideal ladder measure energy differences, so those frequencies alone cannot determine an absolute zero of energy.

Prove discreteness and construct the ground state

Using the product rule for commutators gives

\[[N,a]=-a,\]
\[[N,a^\dagger]=a^\dagger.\]

If a normalisable energy eigenstate has \(N\) eigenvalue \(\nu\), application of \(a\) either annihilates it or yields an eigenstate of eigenvalue \(\nu-1\) and norm squared \(\nu\). Repeated lowering cannot yield a state of negative norm squared. For noninteger nonnegative \(\nu\) the chain would reach \(0<\nu'<1\) with nonzero image at a negative eigenvalue. Therefore the chain must terminate at an integer step in an annihilated ground state. This argument uses the bound oscillator's spectrum and states in the ladder operators' domains. Existence and completeness can also be checked by solving the one-dimensional differential equation with decaying boundary conditions.

In coordinate representation \(P=-i\,d/dX\), so \(a\psi_0=0\) reduces to

\[d\psi_0/dX=-X\psi_0.\]

Its square-integrable solution is

\[\psi_0(X)=\pi^{-1/4} e^{-X^2/2}.\]

Normalised excited states follow by \(|n\rangle=(a^\dagger)^n|0\rangle/\sqrt{n!}\). Orthogonality follows from the self-adjoint number operator with distinct eigenvalues. The coordinates in metres have ground variance \(\sigma_x^2=\hbar/(2m\omega)\), momentum variance \(\sigma_p^2=m\hbar\omega/2\), and zero symmetrised covariance. The geometric ground-state width is thus fixed by mass and trap stiffness. A semiclassical estimate minimising \(\hbar^2/(8m\sigma_x^2)+m\omega^2\sigma_x^2/2\) gives \(E_{\min}=\hbar\omega/2\), because the Gaussian saturates the uncertainty inequality used in that estimate.

In a number state both \(\langle x\rangle\) and \(\langle p\rangle\) vanish. Their fluctuations do not. Substitute \(x=\sigma_x(a+a^\dagger)\). Terms \(a^2,(a^\dagger)^2\) change the occupation by two and have zero diagonal element, whereas \(aa^\dagger\) and \(a^\dagger a\) contribute \(n+1\) and \(n\). Hence \(\langle x^2\rangle_n=(2n+1)\sigma_x^2\); similarly \(\langle p^2\rangle_n=(2n+1)\sigma_p^2\). The mean kinetic and potential energies each equal half the total. Measuring a nonzero rms displacement does not imply that the oscillator centre is undergoing a coherent motion.

Find a state whose centre follows the classical trajectory

Search for a normalised eigenstate of \(a\) with complex eigenvalue \(\alpha\). It is permissible for this non-Hermitian operator to have complex eigenvalues; they label states rather than directly observable outcomes. Expand \(|\alpha\rangle=\sum_n c_n|n\rangle\). Matching every number-state coefficient yields

\[c_{n+1}=\alpha c_n/\sqrt{n+1}.\]

Using the exponential series to normalise gives

\[|\alpha\rangle=e^{-|\alpha|^2/2}\sum_{n=0}^{\infty}\frac{\alpha^n}{\sqrt{n!}}|n\rangle,\]
\[P(n)=e^{-|\alpha|^2}\frac{|\alpha|^{2n}}{n!}.\]

The mean and variance of occupation are both \(|\alpha|^2\). Different coherent states are nonorthogonal: summing the overlap yields

\[|\langle\beta|\alpha\rangle|^2=e^{-|\alpha-\beta|^2}.\]

At displacement difference one in this dimensionless complex plane the overlap probability is still \(e^{-1}=0.368\). A measurement that distinguishes all such nearby coherent preparations perfectly from one copy would contradict this overlap.

Each coefficient acquires \(e^{-i(n+1/2)\omega t}\). Take the common zero-point phase outside the sum, leaving exactly the same expansion with \(\alpha(t)=\alpha e^{-i\omega t}\). Hence \(\langle x(t)\rangle=2\sigma_x\operatorname{Re}\alpha(t)\) and \(\langle p(t)\rangle=2\sigma_p\operatorname{Im}\alpha(t)\). The centred operator \(a-\alpha\) annihilates the state, so its centred quadrature variances match those of the ground state. The packet moves on the classical phase-space ellipse without spreading. In a free particle the quadratic momentum phase causes spreading; in the bound oscillator equally spaced energy levels preserve this particular relative-phase structure.

For a vibrational mode with \(m=2.00\times10^{-25}\) kg and \(\omega=2\pi\times100\) kHz, \(\sigma_x=20.5\) nm. Prepare \(\alpha=1.5i\). Initially the average position is zero and the momentum is positive; a quarter period later the centre reaches \(3\sigma_x=61.5\) nm. The mean occupation is 2.25 and the ground probability is 0.1054. This ensemble has a nonzero ground-state probability even though its position oscillation is clearly resolved by repeated measurements. A pure number state of average energy near this value could give similar rms positions but would show no time-dependent centre.

Background · Which measurement distinguishes two oscillators of equal mean energy?

Compare the first excited number state with a coherent state of amplitude \(\alpha=1\). Both have mean occupation one and hence the same mean energy \(3\hbar\omega/2\). For a number state the expectation of the lowering operator vanishes because it connects orthogonal levels. For a coherent state its expectation equals \(\alpha\) and evolves with the oscillator phase.

\[\langle x(t)\rangle_{\rm coh}=\sqrt{\frac{2\hbar}{m\omega}}\,\mathrm{Re}(\alpha e^{-i\omega t}),\]
\[\langle x(t)\rangle_{n=1}=0.\]

Synchronous position measurements on freshly prepared states distinguish the moving centroid from the stationary one. A repeated energy measurement also separates the preparations. The number state always gives one quantum, whereas the coherent state gives a Poisson distribution with mean and variance both equal to one. A mean energy by itself omits both distinctions.

Rotate an uncertainty ellipse and test a nonideal trap

A sudden frequency change provides an experimentally meaningful way to generate a state with unequal quadrature fluctuations. Prepare the ground state at frequency \(\omega_i\), then instantaneously change to \(\omega_f\). The state in the position representation is continuous through an ideal sudden change. Relative to the final oscillator,

\[\langle X_f^2\rangle=\omega_f/(2\omega_i),\]
\[\langle P_f^2\rangle=\omega_i/(2\omega_f);\]

their product remains \(1/4\). Their sum exceeds one unless the two frequencies coincide. Thus the state is a squeezed vacuum for the new trap, with mean occupation \(\tfrac14(\omega_f/\omega_i+\omega_i/\omega_f-2)\). Unlike a coherent displacement its centre remains zero. Measuring a variance as the ellipse rotates distinguishes these preparations even if their average energies match.

For \(\omega_f=2\omega_i\) the mean occupation is 0.125. Since \(X_f(t)=X_f(0)\cos\omega_ft+P_f(0)\sin\omega_ft\), variance oscillates between 1 and 0.25 in these units with angular frequency \(2\omega_f\). The ground variance for the final trap would be 0.5, so part of the cycle lies below it. Momentum variance rises correspondingly, and at intermediate angles a nonzero covariance is needed in the uncertainty determinant. Abrupt changes also inject work via the time-dependent Hamiltonian. Energy measured before and after the sudden change need not agree even though the state vector at the switching instant is unchanged.

Real traps eventually depart from exact harmonic confinement. Write a model diagonal spectrum \(E_n/\hbar=\omega(n+1/2)+\chi n(n-1)/2\) for weak amplitude-dependent spacings over the occupied range. Coherent-state sums give

\[\langle a(t)\rangle=\alpha e^{-i\omega t}\exp[|\alpha|^2(e^{-i\chi t}-1)].\]

Its magnitude is \(|\alpha|\exp[-|\alpha|^2(1-\cos\chi t)]\). The collapse of the centre can occur under strictly unitary evolution while the number probabilities stay fixed. Their phases reassemble at \(2\pi/|\chi|\) in this ideal spectrum. Irreversible noise and uncontrolled fluctuations can suppress a measured revival; loss of the mean alone does not diagnose dissipation. A position trace and a number-resolved distribution probe complementary parts of the dynamics.

Factor a measured displacement into force history and oscillator response

A linear force couples to position,

\[H(t)=\hbar\omega(N+1/2)-F(t)x.\]

Even if the force time series is irregular, this driven oscillator is exactly soluble within the harmonic approximation. In the Heisenberg picture use \(\dot a=(i/\hbar)[H,a]\). Since \([x,a]=-\sigma_x\), the equation is

\[\dot a=-i\omega a+i\sigma_x F(t)/\hbar.\]

Multiply by \(e^{i\omega t}\) and integrate:

\[a(t)=e^{-i\omega t}\left[a(0)+\frac{i\sigma_x}{\hbar}\int_0^t F(t')e^{i\omega t'}dt'\right].\]

A force therefore displaces the rotating oscillator according to one complex Fourier component of its history. Its phase determines which final quadrature changes. The centred operator still evolves as in free oscillation. Thus a known linear drive displaces a ground state into a coherent state without squeezing it. The same formula shifts a thermal state without removing its thermal fluctuations. The statement about pure coherence requires knowing the initial state as well as measuring the final displacement.

Take a constant force \(F_0\) switched on for time \(T\) then off. For an initially stationary ground state the final amplitude, measured at switch-off in the original oscillator basis, is \(\alpha_F=F_0\sigma_x[1-e^{-i\omega T}]/(\hbar\omega)\). The corresponding mean position is \(F_0(1-\cos\omega T)/(m\omega^2)\), agreeing with the classical step response of a mass on a spring. Its excitation number is \(4(F_0\sigma_x/\hbar\omega)^2\sin^2(\omega T/2)\). A constant force applied for exactly a full period creates zero residual excitation at switch-off even though the oscillator moved substantially during the pulse. Motion of the trap centre and persistent excitation after the trap returns must be experimentally distinguished.

For \(m=2.00\times10^{-25}\) kg and \(100\) kHz as above, let \(F_0=2.00\times10^{-21}\) N. Its static equilibrium displacement is

\[F_0/(m\omega^2)=25.3\,\mathrm{nm}.\]

A half-period pulse leaves the mean at 50.7 nm with zero mean momentum and \(|\alpha|=50.7/(2\times20.5)\simeq1.24\). Its mean added occupation is roughly 1.53. The elastic energy \(m\omega^2\langle x\rangle^2/2\) at switch-off matches \(\hbar\omega|\alpha|^2\), independently of any counting argument. This check subtracts the unchanged zero-point energy. Using the total energy including zero point in the comparison would incorrectly attribute a half quantum to the drive even when the applied force vanishes.

The sudden impulse limit provides another independent test. Let a short pulse deliver total impulse \(J=\int Fdt\) over a time much shorter than \(1/\omega\). The amplitude increment is approximately \(i\sigma_xJ/\hbar\) in the appropriate rotating phase. Since \(2\sigma_p\sigma_x=\hbar\), the mean momentum changes by \(J\). For a smooth pulse spread around one period the same total impulse can produce a much smaller residual excitation because the force acts at different phases of the oscillator. A force sensor based on final occupation measures the squared magnitude of a windowed resonant integral. Reconstructing a complete time-dependent force from that single energy measurement is generally impossible. Varying the drive start time or measuring both final quadratures gives additional information.

Use operator ordering to predict a phase with zero final displacement

Define the displacement operator \(D(\alpha)=\exp(\alpha a^\dagger-\alpha^* a)\). Its generator is anti-Hermitian, so it is unitary. The commutator of \(\alpha a^\dagger-\alpha^*a\) with \(a\) is a constant. Differentiating \(D^\dagger(s\alpha)aD(s\alpha)\) with respect to \(s\) and integrating gives

\[D^\dagger(\alpha)aD(\alpha)=a+\alpha.\]

Consequently \(D(\alpha)|0\rangle\) is an annihilation eigenstate of eigenvalue \(\alpha\), giving an independent physical construction of the number expansion. The normal-order factorisation \(D=e^{-|\alpha|^2/2}e^{\alpha a^\dagger}e^{-\alpha^*a}\) follows from the Baker–Campbell–Hausdorff formula because the relevant commutator is a scalar. Acting on the ground state recovers the Poisson coefficients directly. Omitting the scalar prefactor gives a state with the wrong norm.

Two displacements do not commute as operators despite their effects on the mean phase-space position adding in either order. Their scalar commutator gives

\[D(\alpha)D(\beta)=e^{(\alpha\beta^*-\alpha^*\beta)/2}D(\alpha+\beta).\]

The product around a closed displacement loop is

\[D(\alpha)D(\beta)D(-\alpha)D(-\beta)=e^{\alpha\beta^*-\alpha^*\beta}I.\]

For \(\alpha=1,\ \beta=i/2\) the phase is \(-1\) rad in this written operator order. Reversing the physical order conjugates the phase. The oscillator returns to its initial phase-space position and, apart from this phase, to its initial state. In a single isolated preparation the common phase is invisible. To observe it, place the oscillator interaction under coherent control of one branch of a separate two-level reference, recombine the reference and compare the branch that went around the loop with the branch that did not. Surviving coherence of the reference is essential. The same result can be described as an oriented area in the \(\operatorname{Re}\alpha,\operatorname{Im}\alpha\) plane and ultimately follows from \([x,p]=i\hbar\).

It is useful to trace the actual motion before interpreting a claimed geometric phase. Operators act from right to left on kets, so plotting a particular rectangular loop in time can correspond to the conjugate of a product written left to right. A lab comparison should specify the four pulse phases in chronological order and the ordinary free rotation occurring between them. In the rotating frame the displacement vectors are simple complex increments; in the laboratory frame the oscillator itself continually advances in phase. An uncompensated delay can leave a residual displacement rather than a closed loop. The overlap of that residual displaced ground state with the reference branch is \(e^{-|\Delta\alpha|^2/2}\) in amplitude, reducing observed fringe contrast as well as shifting its phase.

Measure displaced parity to distinguish a number state from a mixture

The number parity operator \(\Pi=(-1)^N\) gives \(+1\) for even and \(-1\) for odd occupation. It implements the coordinate reflection \(x\to-x\) for the harmonic oscillator. A position-space Wigner distribution may be sampled by displacing the state and measuring its parity. In the complex phase-space convention used here define \(W(\beta)=(2/\pi)\operatorname{tr}[D(-\beta)\rho D^\dagger(-\beta)\Pi]\); it integrates to one in \(d^2\beta\). At \(\beta=0\) it is just twice the even-minus-odd probability divided by \(\pi\). Its sign is determined by observable population statistics, but its value at a point is not the probability that a particle occupies a sharp simultaneous position and momentum.

For a coherent input \(|\alpha\rangle\), displacement produces \(|\alpha-\beta\rangle\) up to a phase. Summing the even-minus-odd Poisson occupations gives \(e^{-2|\alpha-\beta|^2}\). Hence \(W(\beta)=2e^{-2|\alpha-\beta|^2}/\pi\), a positive Gaussian. A first excited number state instead has \(W(0)=-2/\pi\). Mix that state with ground-state population,

\[\rho=p|1\rangle\langle1|+(1-p)|0\rangle\langle0|.\]

Then \(W(0)=(2/\pi)(1-2p)\), negative only when \(p>1/2\). An observed lack of negativity at one displacement does not imply a Gaussian state or a globally classical description. It may simply mean that the probe is examining a positive region or that losses have mixed the odd preparation with the ground state.

Suppose an experimental detector distinguishes only “zero excitations” from “one or more”. A measured nonzero fraction of 0.80 does not determine parity without further information: all those events might contain one excitation or a substantial even population might be present. Number resolution or a separate calibrated parity mapping is needed. If only ground and first excited population are independently established, an observed \(p_1=0.70\pm0.02\) gives \(W(0)=-0.255\pm0.025\) in these dimensionless units. Propagating that uncertainty requires the assumption about higher occupations. Combining a displacement scan with number-resolved or parity-sensitive data therefore tests both the preparation and the adequacy of a finite oscillator basis.

Recover a thermal occupation from two independent observables

For an oscillator in thermal equilibrium at inverse temperature \(\beta_T\), the occupation probabilities are \(P_n=(1-q)q^n\) with \(q=e^{-\beta_T\hbar\omega}\). The geometric series gives \(\bar n=q/(1-q)\) and variance \(\bar n(\bar n+1)\). Unlike a coherent state with the same mean occupation, the number distribution is broader and the free mean displacement is zero. The symmetrised position variance is \((2\bar n+1)\sigma_x^2\). A variance measurement alone cannot distinguish a thermal distribution from an incoherent nonthermal mixture with the same mean energy. Resolving more than the variance probes the full probability law.

For example, at \(\bar n=2\) thermal equilibrium predicts ground occupation \(1/3\), number variance 6 and parity \(1/(2\bar n+1)=1/5\). A coherent state with \(|\alpha|^2=2\) gives ground probability 0.1353, variance 2 and parity \(e^{-4}=0.0183\). A uniform randomisation of the coherent phase removes the mean displacement but leaves these Poisson number statistics unchanged. It can therefore resemble the thermal state on a quadrature average while differing sharply in ground population and parity. A displaced thermal preparation adds a classical centre motion on top of the thermal fluctuations; fitting only its energy would confuse displacement with temperature. Centre, centred variance and at least one independent number statistic make a coherent experimental set of observables for these physically different preparations.

Follow a coherent oscillator state in phase space

Change the magnitude and phase of a coherent amplitude independently. Predict which control changes the mean occupation and which shifts the timing of the position measurement.

Recover individual transition probabilities after a sudden trap change

The sudden-frequency experiment predicted mean occupation from the second moments. Number-resolved probabilities provide a stronger test. The initial ground-state wavefunction is even, and changing the trap curvature about the same centre preserves parity. The initial state therefore overlaps only even eigenstates of the final trap. A measured odd population beyond readout uncertainty diagnoses a displaced minimum, parity-breaking drive or imperfect initial preparation. The vanishing of odd occupation is stronger than knowing only the mean and variance of a quadrature.

Write the old annihilator in terms of the new operators,

\[a_i=\cosh r\,a_f-\sinh r\,a_f^\dagger,\]

with \(r=\frac12\ln(\omega_f/\omega_i)\) for this choice of sign. This follows directly by expressing both in the same \(x,p\) and comparing coefficients. The relative sign can change under a different convention for defining the squeeze parameter but all probabilities below are invariant. The old vacuum obeys \((a_f-\tanh r\,a_f^\dagger)|0_i\rangle=0\). In the final number basis \(c_n=\langle n_f|0_i\rangle\), the coefficient of \(|n\rangle\) gives

\[\sqrt{n+1}c_{n+1}=\tanh r\sqrt n\,c_{n-1}.\]

The \(n=0\) equation forces \(c_1=0\), and iteration gives

\[c_{2j}=c_0\frac{\sqrt{(2j)!}}{2^j j!}(\tanh r)^j,\]
\[c_{2j+1}=0.\]

To normalise, use the central-binomial series \(\sum_j\binom{2j}{j}q^j/4^j=(1-q)^{-1/2}\) at \(q=\tanh^2r\). Thus

\[|c_0|^2=1/\cosh r.\]

A separate coordinate-space check follows by integrating the overlap of two Gaussian ground states, giving \(P_0=2\sqrt{\omega_i\omega_f}/(\omega_i+\omega_f)\). This agrees with \(1/\cosh r\), independently of the operator recursion. Differentiating the normalisation-generating series gives \(\bar n=\sinh^2r\), agreeing with the energy inferred from the sudden change of the Hamiltonian.

For a doubling of frequency, \(\tanh r=1/3,\ \cosh r=3/(2\sqrt2)\), so

\[P_0=0.9428,\ P_2=P_0/18=0.05238,\]
\[P_4=P_0(3/8)(1/81)=0.00436.\]

Higher even levels contain the remaining probability. At a mean excitation of 0.125, a coherent state would instead have \(P_1=0.1103\). Even imperfect number resolution discriminating odd versus even can strongly distinguish a pure curvature quench from a coherent displacement with equal final energy. A finite switching time can reduce excitation if the oscillator tracks the moving ground state adiabatically. A shift of trap centre during a nominal curvature change adds a displacement and can populate odd levels. Measure the mean and parity along with the energy estimate before inferring a squeeze strength solely from a single occupation number.

Separate temperature from a parity-preserving quench

Before a sudden centred frequency doubling, a calibrated trap has thermal mean occupation 0.10. Predict the fraction of odd-number results after the quench and its final mean occupation. How might an experiment mistakenly interpret the odd results?

Derive and check the result

In the initial thermal ensemble parity expectation is

\[1/(2\bar n+1)=1/1.2=0.8333.\]

Parity commutes with both centred trap Hamiltonians, and measuring even or odd final occupation measures that same parity operator. The odds fraction is therefore \((1-0.8333)/2=0.0833\), unchanged by the quench. The final energy fluctuations scale with the initial quadrature variances multiplied by \(2\bar n+1\), giving \(\bar n_f+1/2=(\bar n_i+1/2)(\omega_f/\omega_i+\omega_i/\omega_f)/2=0.75\). Thus \(\bar n_f=0.25\). Assuming a perfectly cold initial state might turn the observed odd fraction into a false diagnosis of trap displacement. Measure initial parity and post-quench parity independently to isolate processes that actually break the symmetry. The increase of mean occupation alongside unchanged parity is the predicted signature of a centred quench.

Tutorial · analyse a state from amplitude and fluctuation data

Test two preparations with the same mean energy

Take a coherent state with \(|\alpha|^2=3\) and number state \(|3\rangle\). Compare energies, number variance, ground probability and the largest possible mean displacement.

Work through the solution

Both have \(\langle H\rangle=3.5\hbar\omega\). The coherent number variance is 3 while the number-state variance is zero. Ground probabilities are \(e^{-3}=0.0498\) and zero. By selecting a suitable oscillator phase, the coherent state reaches \(2\sqrt3\sigma_x\); the number state has zero centre at every time. An energy average alone leaves these preparations indistinguishable. The event of measuring exactly three quanta has probability \(e^{-3}3^3/3!=0.224\) in the coherent case and unity in the number case. Repeated shots allow this comparison without assuming a single shot reveals the input state.

Estimate numerical truncation before trusting a simulated coherent state

Expand a coherent state with \(\alpha=2\) in number states \(0,\ldots,8\). Is the missing probability negligible at a desired accuracy of one part in a thousand?

Work through the solution

Generate probabilities successively from \(p_0=e^{-4}\), \(p_{n+1}=4p_n/(n+1)\); summing through 8 gives 0.97864, leaving 0.02136 above the cutoff. Renormalising the retained vector hides this discarded probability from a norm check and distorts quantities weighted by \(n\). Through \(n=11\) the tail is about 0.00092, just below the specified probability tolerance. Energy moments require a separate tail weighted by \(n\); a probability bound alone can be inadequate for them. Vary the cutoff while monitoring both number statistics and the centre motion to separate truncation artefacts from real dephasing.

Infer the coherent displacement and a squeezing test

At a known phase, measurements give

\[\langle x\rangle=1.2\sigma_x,\ \langle p\rangle=-1.6\sigma_p.\]

Infer the coherent amplitude consistent with those means, then say what must still be measured to confirm a coherent preparation.

Work through the solution

The means imply \(\operatorname{Re}\alpha=0.60,\ \operatorname{Im}\alpha=-0.80\), so \(|\alpha|=1\) and the putative coherent mean occupation is one. They do not fix the variances. A displaced thermal or squeezed state can produce the same means with different fluctuations. Measure the variance along independent quadratures, including a rotated axis to infer covariance. In an ideal normalised state the expectation of the positive operator \((a-\alpha)^\dagger(a-\alpha)\) equals \(\langle N\rangle-|\alpha|^2\). If it vanishes exactly, the support is in the kernel of \(a-\alpha\), giving the coherent state. With finite uncertainty a near-zero value instead bounds extra excitation in the displaced frame.

Further reading

From a Coulomb orbit to the fine-structure multiplet

Separate the hydrogenic Schrödinger equation, identify the origin of its large degeneracy and evaluate the three dominant relativistic corrections. The cancellation among them predicts an equality that spectroscopy can then test.

Separate centre-of-mass and relative motion

A light particle of mass \(m_e\) and charge \(-e\) interacts with a pointlike nucleus \(+Ze\) of mass \(M\). Use centre of mass \(\mathbf R=(m_e\mathbf r_e+M\mathbf r_N)/(m_e+M)\) and separation \(\mathbf r=\mathbf r_e-\mathbf r_N\). Expanding the sum of the two kinetic energies cancels all cross terms and gives a free centre-of-mass kinetic energy plus relative energy \(p^2/(2\mu)\), with reduced mass \(\mu=m_eM/(m_e+M)\). The relative potential is \(-k/r,\ k=Ze^2/(4\pi\epsilon_0)\). Its rotational symmetry implies \([H,L_i]=0\). Use a spherical harmonic \(Y_{lm}\) and write \(\psi=u(r)Y_{lm}/r\), so the probability in a thin radial shell is \(|u(r)|^2dr\) for angular harmonics of unit norm.

Substituting in the Laplacian separates the radial equation

\[-\frac{\hbar^2}{2\mu}u''+\left[\frac{\hbar^2l(l+1)}{2\mu r^2}-\frac{k}r\right]u=Eu .\]

For the regular three-dimensional solution \(u(0)=0\) and a bound state also decays at infinity. The centrifugal term is an effective energy associated with angular variation, not a separate force added by hand. For \(E<0\) define \(\kappa=\sqrt{-2\mu E}/\hbar,\ \rho=2\kappa r\), and \(a=\hbar^2/(\mu k)\). The small-radius behaviour of \(u\) is \(r^{l+1}\); the large-radius tail contains \(e^{-\kappa r}\). Pull both out by \(u=\rho^{l+1}e^{-\rho/2}v(\rho)\). Straight differentiation leaves

\[\rho v''+(2l+2-\rho)v'+(1/\kappa a-l-1)v=0 .\]

For \(v=\sum c_j\rho^j\), coefficient matching gives

\[c_{j+1}/c_j=(j+l+1-1/\kappa a)/[(j+1)(j+2l+2)].\]

The regular series must terminate to avoid an exponential asymptotic part that defeats the decaying prefactor. Thus \(1/(\kappa a)=n_r+l+1=n\), and \(E_n=-\mu k^2/(2\hbar^2 n^2)\). The normalised radial polynomials are associated Laguerre functions. This gives \(l=0,\ldots,n-1\) and \(\sum_l(2l+1)=n^2\) states before including spin. Rotational symmetry guarantees the degeneracy in \(m\), but a different central potential can split levels of different \(l\). The additional equality is specific to the Coulomb potential.

Calculate the radial moments needed for a correction

To isolate the leading relativistic corrections now take an infinitely heavy nucleus and set \(m=m_e\), \(a=\hbar^2/(mk)\). Including reduced mass in the leading energy is straightforward; a complete recoil correction to the fine structure requires additional interactions. A useful identity is \(\langle1/r\rangle=1/(an^2)\), obtained by differentiating \(E_n\) with respect to \(k\). The derivative of an eigenvalue equals the expectation of \(\partial H/\partial k=-1/r\) for the normalised eigenstate, which follows by differentiating \(H|\psi\rangle=E|\psi\rangle\) and cancelling terms using its adjoint. The same method applied to the radial centrifugal parameter yields \(\langle r^{-2}\rangle=1/[a^2n^3(l+1/2)]\) at fixed radial node count. Treat \(l\) as a continuously varied radial parameter during differentiation, then evaluate at its physical integer value.

For \(l>0\), the stationary radial force identity \(\langle dV_{\rm eff}/dr\rangle=0\) with vanishing endpoint term gives

\[\langle r^{-3}\rangle=1/[a^3n^3 l(l+1/2)(l+1)].\]

Here \(V_{\rm eff}\) is the potential in the radial equation. The step uses sufficient behaviour of \(u,u'\) at the origin. For \(l=0\), the integral of \(r^{-3}\) diverges in an \(s\) state and the neglected endpoint term need not vanish. Substituting \(l=0\) formally into this expression would therefore be invalid. The contact density of an \(s\) state needed below is \(|\psi_{n00}(0)|^2=1/(\pi a^3 n^3)\), while states with \(l>0\) vanish at the origin.

Track the kinetic, spin–orbit and contact terms separately

The small parameter is \(Z\alpha=k/(\hbar c)\), with \(\alpha\) the fine-structure constant for \(Z=1\). Expand the relativistic dispersion about small momentum after subtracting rest energy: \(p^2/(2m)-p^4/(8m^3c^2)+\cdots\). For an energy eigenfunction \(p^2\psi=2m(E_n+k/r)\psi\), so \(\langle p^4\rangle=4m^2\langle(E_n+k/r)^2\rangle\) follows by taking the squared norm of \(p^2\psi\). Squaring the two operators as if \(p^2\) and \(1/r\) commute is unnecessary and would not be an operator identity. Inserting the first two radial moments gives

\[\Delta E_{\rm kin}=-C_n\left[\frac1{l+1/2}-\frac3{4n}\right],\]
\[C_n=\frac{mc^2(Z\alpha)^4}{2n^3}.\]

The Pauli expansion of the Dirac Hamiltonian adds \(H_{\rm so}=(1/[2m^2c^2r])V'(r)\mathbf L\cdot\mathbf S\) and the Darwin contact \(H_D=\hbar^2\nabla^2 V/(8m^2c^2)\). These are effective interactions through order \((Z\alpha)^4\); a purely nonrelativistic scalar equation does not generate the spin or contact term. For \(V=-k/r\), \(V'=k/r^2\) and \(\nabla^2 V=4\pi k\delta^3(\mathbf r)\). Thus the contact shifts only \(s\) states by \(+C_n\). For \(l>0\) insert the third inverse radial moment and the angular identity \(\mathbf L\cdot\mathbf S=\hbar^2[j(j+1)-l(l+1)-3/4]/2\). For the branch \(j=l+1/2\) the bracket is \(l\); for \(j=l-1/2\) it is \(-(l+1)\). Reducing fractions then gives

\[\Delta E_{\rm so}=C_n[1/(l+1/2)-1/(j+1/2)].\]

For \(l=0\) the spin–orbit operator vanishes and the Darwin term supplies the required difference. The sum in either case is

\[\Delta E_{nj}=-C_n\left[\frac1{j+1/2}-\frac3{4n}\right].\]

At fixed \(n\) the answer depends on \(j\) but no longer separately on \(l\). The cancellation cannot be inferred by merely attaching a phenomenological \(\mathbf L\cdot\mathbf S\) splitting to a nonrelativistic \(p\) state. In particular it predicts identical energies for \(2s_{1/2}\) and \(2p_{1/2}\) in this approximation, while \(2p_{3/2}\) lies higher. Radiative, recoil and finite-nuclear-size contributions can resolve some of these residual equalities. An experimentally resolved residual is evidence that the specified Hamiltonian omitted a physical term; it does not remove the cancellation inside that Hamiltonian.

Compare a small energy correction with a resolvable line

For hydrogen with \(mc^2\simeq511\,000\) eV and \(\alpha\simeq1/137.04\), the \(2p_{3/2}\)–\(2p_{1/2}\) interval is \(C_2/2\simeq4.53\times10^{-5}\) eV or \(10.95\) GHz. Compare with the leading \(n=2\) binding energy 3.40 eV. A small correction to total binding can give a prominent splitting when a measurement subtracts nearly equal large energies. Resolving it in a Fourier-limited time-domain experiment requires a coherent observation time at least of order the inverse frequency difference, here around 0.09 ns. Actual linewidths, lifetimes and pulse shapes affect how two spectral components can be distinguished.

A useful numerical audit is to fit the radial spectrum with three successive physical models. First solve the nonrelativistic radial boundary problem with the correct near-origin power and check that 2s and 2p converge toward the same energy. Then evaluate expectation values of the three corrections on those numerical states. Finally combine terms. Converged binding energies alone do not guarantee a converged contact density, which samples one spatial endpoint. A coarse radial grid can imitate an anomalous splitting between states which the analytical correction predicts to be equal. Check the origin slope of \(u_{n0}\), not only its norm or far tail.

Find where the electron is most likely to be detected

Confusion between spatial density and radial probability can lead to very different-looking descriptions of the same atom. For a hydrogenic ground state the normalised position-space wavefunction is \(\psi_{100}=(\pi a^3)^{-1/2}e^{-r/a}\). Its density is largest at the centre, but a thin spherical shell at radius \(r\) contains probability \(P(r)dr=4r^2 e^{-2r/a}dr/a^3\). The shell volume tends to zero at the origin. Differentiating \(\ln P\) gives \(2/r-2/a=0\), so the most likely shell radius is \(a\). The mean radius \(\int rP(r)dr=3a/2\) is different again because the shell distribution has a long tail. Neither number alone gives the probability that a finite spatial detector clicks.

Integrating the shell probability between zero and \(R\) gives

\[\Pr(r<R)=1-e^{-2R/a}\left(1+\frac{2R}a+\frac{2R^2}{a^2}\right).\]

At the most likely shell radius \(R=a\), the probability inside is \(1-5e^{-2}=0.3233\), substantially less than one half. At \(R=2a\) it is

\[1-13e^{-4}=0.7619.\]

Taylor expansion at a small radius \(R\ll a\) gives \(4(R/a)^3/3\), equal to the ball volume times central density to leading order. This is the local scaling underlying finite-nucleus corrections to a contact-sensitive observable. Using the most likely radius as though the electron followed a thin circular orbit would give none of these cumulative probabilities, even though the same Coulomb length scale appears in the Bohr model.

For \(2s\) and \(2p\), both states have principal index two and the same leading energy. The \(2s\) radial amplitude is proportional to \((2-r/a)e^{-r/(2a)}\); its node at \(2a\) separates regions of opposite amplitude sign. The \(2p\) radial amplitude is proportional to \(r e^{-r/(2a)}\), with no positive-radius radial node. At short distance, the probability inside \(R\) scales as \(R^3\) for a nonzero \(s\) amplitude and as \(R^5\) for the \(p\) wave. A sufficiently localised weak perturbation near the nucleus can therefore split the nonrelativistic degeneracy even if it is rotationally symmetric. Rotational symmetry still protects equal shifts within the \(m\) multiplet. A radial perturbation and a field selecting a direction leave different patterns of protected degeneracy.

Diagonalise a degeneracy before expanding a weak electric field

The \(n=2\) Coulomb degeneracy creates a striking response to a weak uniform electric field along \(z\). In the purely nonrelativistic model with spin ignored the relevant spatial states are \(2s,\ 2p_0,\ 2p_{\pm1}\). The perturbation for an electron in electric field \(\mathcal E\hat z\) can be written \(e\mathcal E z\) up to an additive constant. Each unperturbed parity eigenstate has zero diagonal expectation of this odd operator. Applying ordinary nondegenerate first-order perturbation theory separately to all four states would therefore predict zero for every shift. But first-order perturbation theory in a degenerate manifold requires diagonalising the projected perturbation, including off-diagonal amplitudes.

The \(z=r\cos\theta\) operator has \(q=0\) and changes parity, so within \(n=2\) it couples only \(2s\) and \(2p_0\). Its angular matrix element between \(Y_{00}\) and \(Y_{10}\) is \(1/\sqrt3\). In a conventional phase convention the radial functions are \(R_{20}=(2-r/a)e^{-r/(2a)}/(2\sqrt2\,a^{3/2})\) and \(R_{21}=(r/a)e^{-r/(2a)}/(2\sqrt6\,a^{3/2})\). The remaining radial integral is \(\int r^3R_{20}R_{21}\,dr\). Setting \(s=r/a\) gives

\[a(2\cdot4!-5!)/(8\sqrt3)=-3\sqrt3a.\]

Multiplying the angular factor gives \(-3a\). Rephasing one basis state would change this sign but leave all level shifts invariant.

The projected matrix has zero diagonal and off-diagonal \(-3ea\mathcal E\). Its symmetric and antisymmetric combinations have linear shifts \(\mp3ea\mathcal E\), while \(2p_{\pm1}\) remain unshifted to this order. The new states have definite first-order dipoles along opposite directions even though their zero-field basis states had zero dipoles. For \(a=5.29\times10^{-11}\) m and \(\mathcal E=1000\) V/m, an individual linear shift has magnitude \(1.59\times10^{-7}\) eV, corresponding to 38.4 MHz. This field is weak compared with the gross level separation, but whether the degenerate result is accurate in a real atom also depends on much smaller fine, hyperfine and radiative splittings. “Weak field” must specify the comparison energy.

A more precise two-state model retains a zero-field splitting \(\Delta\) between the coupled states. After subtracting their mean the Hamiltonian is \((\Delta/2)\sigma_z+d\mathcal E\sigma_x\), with \(d=3ea\) in magnitude. The energies are \(\pm\sqrt{(\Delta/2)^2+d^2\mathcal E^2}\). At \(d|\mathcal E|\ll|\Delta|\) the shift from each initial level is quadratic, \(\pm d^2\mathcal E^2/|\Delta|\), while at \(d|\mathcal E|\gg|\Delta|\) the slopes approach the linear-degenerate prediction. An observed crossover distinguishes a small unresolved internal splitting from a strictly zero projected dipole matrix element. Tracking energies over both positive and negative fields also tests for a stray dc field shifting the centre of the response.

Estimate a finite-size correction from the potential itself

The contact term derived from the Pauli expansion is not the same physical effect as giving the nucleus a finite charge radius. A simple electrostatic model separates the two scalings. Replace a point nucleus by a uniformly charged sphere of radius \(R_N\). Inside it the electron potential becomes

\[V_{\rm sph}(r)=-k[3-(r/R_N)^2]/(2R_N);\]

outside it is unchanged at \(-k/r\). The perturbation \(\delta V=k[1/r-3/(2R_N)+r^2/(2R_N^3)]\) is positive for interior points and zero at the surface. The smoothed potential is less attractive than the point law near the centre.

For an \(s\) state and \(R_N\ll a\), the unperturbed density varies little across the tiny sphere. First-order perturbation theory therefore gives

\[\delta E\simeq4\pi k|\psi(0)|^2\int_0^{R_N}\left(r-\frac{3r^2}{2R_N}+\frac{r^4}{2R_N^3}\right)dr\]
\[\frac{2\pi}{5}\,k|\psi(0)|^2R_N^2 .\]

The first two radial integrals cancel and leave the \(R_N^2/10\) contribution before multiplication by \(4\pi\). Equivalently write \(\delta E=(2\pi/3)k|\psi(0)|^2\langle r_N^2\rangle\), since the uniform sphere has mean-square charge radius \(3R_N^2/5\). The result is a positive shift, decreasing binding. Corrections to the constant-density approximation involve additional powers of \(R_N/a\). A different microscopic charge distribution changes higher moments, while the leading small-size shift depends on its mean-square charge radius.

For a model \(R_N=1.0\) fm and the ordinary electronic hydrogen length \(a=5.29\times10^{-11}\) m, \(R_N/a=1.89\times10^{-5}\). For the ground state compare with \(|E_1|=k/(2a)\) and \(|\psi(0)|^2=1/(\pi a^3)\). The relative shift is \((4/5)(R_N/a)^2=2.86\times10^{-10}\), equivalent to roughly \(3.9\times10^{-9}\) eV. This illustrative uniform charge radius is input data of the model; do not equate it directly to a measured rms radius. For a heavier orbiting lepton a shorter Bohr radius increases the fractional sensitivity strongly. A complete precision spectrum would additionally include radiative and recoil effects and a realistic nuclear response. The present derivation isolates how one local perturbation scales and why \(s\) levels are especially sensitive.

Use dilation to audit stationary Coulomb energies numerically

A variational scaling argument gives a powerful independent check on a computed wavefunction. For any normalised trial state \(\psi\), define the normalised rescaling \(\psi_\lambda(\mathbf r)=\lambda^{3/2}\psi(\lambda\mathbf r)\). The Coulomb potential is homogeneous of degree minus one, and the gradient acquires a factor \(\lambda\). Its energy expectation is therefore

\[E(\lambda)=\lambda^2\langle T\rangle+\lambda\langle V\rangle.\]

For an exact stationary bound state the energy functional is stationary with respect to norm-preserving variations, giving \(2\langle T\rangle+\langle V\rangle=0\) at \(\lambda=1\). Hence \(\langle T\rangle=-E,\ \langle V\rangle=2E\), consistent with the independently derived inverse-radius mean. The argument requires appropriate normalisation and boundary behaviour so the scaled trial function is allowed.

Suppose a numerical \(1s\) reconstruction yields \(\langle T\rangle=13.2\) eV and \(\langle V\rangle=-26.7\) eV. Its energy is \(-13.5\) eV, yet its virial residual is \(-0.3\) eV. Along the scale family the minimum occurs at \(\lambda_*=-\langle V\rangle/(2\langle T\rangle)=1.0114\), a slightly more concentrated state. The resulting energy reduction is only about 0.0017 eV, much smaller than the change in individual kinetic and potential terms. A small total-energy error can coexist with a noticeably incorrect radial scale because first-order energy errors cancel near a stationary solution. Monitoring separate expectation values, the virial residual and a contact-sensitive observable provides a more informative test of a numerical atomic calculation than reporting the total binding energy alone.

Distinguish orbital density from radial probability

Compare radial states at the same principal quantum number. Inspect their nodes before considering which additional interactions can lift their degeneracy.

Appraise a finite-grid Coulomb spectrum from convergence and degeneracy

To compute the radial Schrödinger eigenvalues directly, work in dimensionless radius \(s=r/a\), energy unit \(\hbar^2/(2ma^2)\), and write \([-d^2/ds^2+l(l+1)/s^2-2/s]u=\varepsilon u\). On a uniform grid \(s_j=jh\), use \(u_0=0\) and a far boundary \(u_{N+1}=0\). The diagonal approximation is \(2/h^2+l(l+1)/s_j^2-2/s_j\) and its neighbours are \(-1/h^2\). All potential terms are evaluated at positive interior grid points. Inserting an arbitrary finite value for \(1/s\) at the origin and treating it as an ordinary interior point changes the boundary approximation. A tridiagonal symmetric eigensolver returns orthogonal numerical vectors; physical radial norm is \(h\sum_j|u_j|^2\), so normalise appropriately before reconstructing spatial densities.

For \(l=0\) on an infinite grid the lowest mode permits an unusually informative exact lattice check. Try \(u_j=j q^j\) for \(0<q<1\). The finite-difference kinetic row divided by this trial value is \([2-q-q^{-1}]/h^2-(q-q^{-1})/(jh^2)\). Adding potential \(-2/(jh)\), the \(1/j\) coefficient vanishes when \(q^{-1}-q=2h\), or \(q=\sqrt{1+h^2}-h\). The eigenvalue is then

\[\varepsilon_h=[2-2\sqrt{1+h^2}]/h^2=-2/[1+\sqrt{1+h^2}].\]

It tends to the exact continuum ground value \(-1\) as \(-1+h^2/4+O(h^4)\). This analytic discrete answer separates algebraic solver correctness from discretisation error for the exact same potential and boundary treatment.

At \(h=0.20\) the infinite-grid ground value is approximately \(-0.99020\); at \(h=0.10\) it is \(-0.99751\). Their errors differ by nearly a factor of four as predicted. A finite far wall shifts both energies further; repeat first at fixed \(h\) and increasing boundary radius to isolate that effect. An excited \(n=2\) state has a more extended tail and requires a larger radius than the ground state for comparable truncation bias. Solving \(l=0\) and \(l=1\) on a small common box can yield a spurious nonrelativistic 2s–2p splitting. Check separately that both energies tend to \(-1/4\) before interpreting a much smaller physical fine splitting. Subtracting independently computed energies amplifies absolute numerical biases even if each number appears visually close to its expected value.

The distinctive near-origin behaviour supplies a second check. Since \(\psi_{100}(0)\) is proportional to the slope of the reduced radial function at zero, a first forward difference \(u_1/h\) typically incurs a first-order error even when the energy error is second order. For the lattice shape above \(u_j\propto j q^j\), the first two positive grid values can be used to estimate the endpoint derivative by \((4u_1-u_2)/(2h)\). Test its convergence under the physical radial normalisation. For a contact perturbation, squaring an endpoint derivative doubles its small relative error to leading order. This is why an atomic calculation should include an observable-specific refinement criterion in addition to an energy tolerance.

Use an eigenvalue benchmark to separate numerical and physical shifts

A report on the infinite-grid hydrogenic ground state quotes energy \(-0.99750\) at \(h=0.10\) and attributes the difference from \(-1\) to a short-range interaction. Predict the lattice-only change on refinement to \(h=0.05\), and propose a test that could reveal a real interaction independently.

Derive and check the result

The lattice expression gives \(-2/[1+\sqrt{1.0025}]\simeq-0.999376\) at 0.05, so the discretisation alone accounts for the original difference at the stated accuracy. A local physical correction with fixed continuum strength should converge toward a fixed nonzero shift as \(h\to0\), while the lattice bias vanishes approximately as \(h^2/4\). Compute control and perturbed energies on exactly the same grids and compare their difference under refinement, with consistent treatment of the perturbation's physical range. An unresolved delta perturbation represented as a fixed diagonal value on one grid point changes its effective continuum strength upon refinement and would produce another artificial shift. Cross-check with the first-order expectation of a resolved physical potential or with the independently converged contact density.

Use an isotope pair to cancel a common transition-energy reference

High-precision spectroscopy often obtains its most reliable insight from combinations of frequencies rather than absolute energies. Consider two hydrogenic model isotopes with the same nuclear charge, different reduced masses \(\mu_1,\mu_2\) and different mean-square charge radii \(R_1^2,R_2^2\). For a specified transition the leading point-Coulomb frequency can be written \(C\mu\), since its \(n\)-dependent dimensionless numbers are fixed. A local nuclear-size perturbation shifts each participating \(s\) level by a factor proportional to \(|\psi_{ns}(0)|^2 R_i^2\propto\mu_i^3 R_i^2/n^3\), while a \(p\) level receives a much smaller finite-size correction in the same limit. The different powers of reduced mass and radial quantum number permit differences of transitions to cancel selected terms.

For illustration compare a 1s–2s optical frequency with a 1s–2p frequency within one model isotope, assuming the fine, radiative and differing upper-state structures have been independently accounted for in the desired order. Subtracting these frequencies cancels the entire common lower 1s energy and the gross equal 2s/2p Coulomb energy, leaving the upper 2s–2p differences. If instead one sought the large 1s contact contribution, subtracting these same two lines would remove precisely the effect of interest. An apparently convenient common reference can therefore eliminate physical signal as well as noise. Write the coefficient of each contributing level explicitly before selecting a frequency combination.

Suppose two independently fitted line frequencies \(\nu_a,\nu_b\) each have a 10 MHz common reference error and independent residual standard errors of 0.30 and 0.40 MHz. The covariance from the shared reference is \(100\,\mathrm{MHz}^2\). The difference has variance \(0.30^2+0.40^2=0.25\,\mathrm{MHz}^2\), hence 0.50 MHz standard error. Treating both total errors as independent instead would suggest roughly 14 MHz. Conversely, an error in a calibration scale proportional to frequency leaves a residual proportional to the frequency difference; its cancellation is only approximate. Reporting the provenance of uncertainties and their covariance can matter more than recording an extra digit of each absolute transition.

Recover a contact shift from two excited-state probes

In a diagnostic model a local perturbation gives an unknown positive 1s shift \(D\), an \(ns\) shift \(D/n^3\), and zero shifts of \(p\) levels. Relative to a matched reference, how do 1s–2s, 1s–2p and 1s–3s frequencies change? Which experimental difference removes the unknown common lower-state shift yet recovers \(D\)?

Derive and check the result

The changes are \((-7D/8)/h,\ -D/h,\ (-26D/27)/h\), respectively. Subtracting the 1s–2p shift from the 1s–2s shift gives \(D/(8h)\), since the common lower-state contribution cancels. For a measured difference of \(0.90\pm0.05\) MHz the implied \(D/h=7.2\pm0.4\) MHz. The 1s–3s shift should then be \(-6.93\) MHz in this stipulated model. If unavailable corrections also differ among the upper states, that value is not an absolute nuclear-radius extraction. The third line gives an independent test of the \(1/n^3\) contact scaling before attributing all measured differences to the single parameter \(D\).

Tutorial · measure degeneracy through independent calculations

Verify two inverse moments directly in the \(2p\) state

Use \(R_{21}(r)=r e^{-r/(2a)}/(2\sqrt6\,a^{5/2})\) and normalised \(Y_{1m}\). Evaluate \(\langle r^{-2}\rangle,\langle r^{-3}\rangle\) without parameter differentiation.

Work through the solution

The radial measure is \(r^2dr\), so after inserting \(R\) the general moment is \((24a^5)^{-1}\int_0^\infty r^{4-q}e^{-r/a}dr\) for \(r^{-q}\). For \(q=2\) the integral is \(2a^3\), giving \(1/(12a^2)\). For \(q=3\) it is \(a^2\), giving \(1/(24a^3)\). Both agree with the formulas for \(n=2,l=1\). Dropping the radial Jacobian would change both powers and could falsely suggest singular behaviour. The result is independent of \(m\) because the operator is rotationally scalar.

Calculate the complete \(n=2\) shifts in units of \(C_2\)

Resolve the kinetic, spin–orbit and Darwin contributions for \(2s_{1/2}\), \(2p_{1/2}\) and \(2p_{3/2}\). Which comparison isolates the effect of the spin–orbit term cleanly at this order?

Work through the solution

For \(s\), kinetic gives \(-[2-3/8]=-13/8\) and Darwin \(+1\), summing to \(-5/8\). For both \(p\) states the kinetic value is

\[-2/3+3/8=-7/24.\]

The spin–orbit corrections are \(2/3-1=-1/3\) for \(j=1/2\) and \(2/3-1/2=1/6\) for \(j=3/2\), giving \(-5/8\) and \(-1/8\). Subtracting the two \(p\) levels removes their shared kinetic term and zero contact term. Their interval is \(C_2/2\). Comparing 2s with either \(p\) instead involves two different radial wavefunctions and does not isolate the same correction.

Separate a reduced-mass shift from fine structure

Consider two otherwise identical hydrogenic nuclei with \(M/m=1836\) and 3672. Predict the ratio of gross transition frequencies and compare its fractional change with the order of a fine-structure correction. Which common interpretation would conflate them?

Work through the solution

Gross transition frequencies scale as reduced mass \(\mu=m/(1+m/M)\). The heavier-to-lighter ratio is \((1+1/1836)/(1+1/3672)=1.000272\) approximately. The order of a relative fine-structure correction for \(Z=1\) is \(\alpha^2\simeq5.3\times10^{-5}\) with state-dependent coefficients. A change of isotope can shift a gross line by more than a particular resolved fine splitting, even with identical nuclear charge. Centroid measurements across isotopes and intervals within one multiplet are distinct observables. Recoil and nuclear magnetism require further inputs for precision predictions.

Further reading

When a magnetic field changes the quantum numbers of an atom

Weak-field Zeeman slopes label total-angular-momentum multiplets. At stronger fields those slopes curve and intensities migrate. Solve an entire orbital-plus-spin manifold and infer coupling constants from measurable line positions and polarisation.

Choose the Hamiltonian appropriate to a resolved orbital manifold

Suppose an isolated atomic \(p\) manifold with \(l=1,s=1/2\) is sufficiently far from other orbital or principal levels to treat only its six substates. Take \(z\) along a uniform external magnetic field \(B\). Work to first order in the electronic Zeeman operator and model spin–orbit coupling by the constant \(A>0\). With \(b=\mu_B B\) and electron spin factor approximated by two,

\[H=\frac A{\hbar^2}\mathbf L\cdot\mathbf S+\frac b\hbar(L_z+2S_z).\]

Both \(A\) and \(b\) are energies. The sign of the second term is positive for the electron because magnetic moment is opposite to angular momentum and field energy is minus moment dot field. Here \(\mu_B=e\hbar/(2m_e)>0\). The orbital manifold approximation requires magnetic splittings small compared with gaps to omitted levels. Neglected terms can include the difference of the actual spin factor from two, hyperfine interactions and the diamagnetic \(B^2\) term. An “intermediate field” in this discussion means \(b\) comparable to \(A\); it need not exceed any other electronic binding scale.

At zero field the coupled levels \(j=1/2,3/2\) have energies \(-A,+A/2\). At nonzero field the projection \(m=m_l+m_s\) is still conserved because \([H,J_z]=0\). For intermediate fields \(J^2\) need not commute with the Zeeman term. Consequently the six-state problem reduces to two one-dimensional and two two-dimensional invariant blocks, even when the label \(j\) loses its exact meaning. Following a state by magnetic quantum number and overlap with a neighbouring field value is generally more reliable than sorting all computed energies from low to high. Crossings of different \(m\) can reorder a sorted list without exchanging the underlying states.

Derive the Landé slope from angular momentum projection

In a state with definite \(j,l,s,m\), expectation of any vector operator proportional in direction to \(\mathbf J\) within its irreducible multiplet can be obtained from its scalar projection on \(\mathbf J\). For spin,

\[\frac{\langle S_z\rangle}{\hbar}=m\,\frac{j(j+1)+s(s+1)-l(l+1)}{2j(j+1)} .\]

One way to obtain the projection numerator is \(2\mathbf S\cdot\mathbf J=J^2+S^2-L^2\). Since \(L_z+2S_z=J_z+S_z\), the energy slope for weak fields is \(dE/db=g_jm\) with \(g_j=1+[j(j+1)+s(s+1)-l(l+1)]/[2j(j+1)]\). A state \(j=0\) has vanishing linear vector moment and should be treated separately instead of dividing by zero. Within the \(p\) manifold the \(j=1/2\) factor is \(2/3\) and the \(j=3/2\) factor \(4/3\). For \(m=+1/2\) these correspond to slopes \(1/3\) and \(2/3\) in energy units of \(b\). Their sum is exactly one, a trace constraint that remains valid for the sum of the two eigenvalues in that block at every field.

If \(A/h=8.00\) GHz as in the previous angular exercise, the zero-field interval is 12.00 GHz. At \(B=20.0\) mT, \(b/h\simeq0.280\) GHz using \(\mu_B/h=13.996\) GHz/T. The two positive-\(m\) shifts to linear order are \(+0.0933\) and \(+0.1866\) GHz. Actual optical frequencies measure final minus initial energies; an initial \(s_{1/2}\) level has its own Zeeman slope. Omitting it is a common reason a slope inferred from a line scan seems inconsistent with the expected Landé factor.

Diagonalise the mixed levels across the entire crossover

In the \(m=+1/2\) product basis \((|0,\uparrow\rangle,|1,\downarrow\rangle)\), expand \(\mathbf L\cdot\mathbf S=L_zS_z+(L_+S_-+L_-S_+)/2\). The diagonal spin–orbit elements are \(0,-A/2\); the off-diagonal element is \(A/\sqrt2\). The Zeeman term is diagonal with entries \(b,0\). Hence

\[H_+(b)=\begin{pmatrix}b&A/\sqrt2\\ A/\sqrt2&-A/2\end{pmatrix},\qquad E_\pm(b)=\frac{b-A/2}{2}\pm\frac12\sqrt{(b+A/2)^2+2A^2}.\]

At \(b=0\) the square root is \(3A/2\), recovering the coupled levels. For the \(m=-1/2\) basis \((|0,\downarrow\rangle,|-1,\uparrow\rangle)\), replace \(b\) by \(-b\). The stretched levels \(|1,\uparrow\rangle\) and \(|-1,\downarrow\rangle\) remain product states at every field with energies \(A/2\pm2b\). Counting all levels and their traces provides an independent check: spin–orbit and Zeeman each have zero trace in the full six-dimensional space. At zero field both slopes in the \(+\) block are finite and positive. At large positive \(b\) the upper slope tends to one and the lower to zero, approaching their uncoupled product labels.

In the negative-\(m\) block the two uncoupled energies would cross at \(b=A/2\). The coupling opens a minimum gap \(\sqrt2A\). Within the model, levels of the same \(m\) avoid one another whenever this matrix element is nonzero. Crossings between different \(m\) can remain exact because the uniform \(z\)-directed Hamiltonian does not mix them. A tilted perturbation could turn some of these into avoided crossings. Such symmetry dependence matters when trying to infer a coupling from the smallest visible distance between any two lines.

Obtain an eigenvector weight from an energy derivative

Suppose an initial \(s\) state has spin up. A weak \(q=0\) electric-dipole drive prepares the product basis state \(|0,\uparrow\rangle\) in the \(m=+1/2\) block. Its squared overlap with an exact eigenstate determines the angular part of that optical line's strength. Rather than computing a mixing angle with a branch ambiguity, differentiate the exact energies. Since \(\partial H_+/\partial b=|0,\uparrow\rangle\langle0,\uparrow|\), the eigenvalue derivative equals precisely that population:

\[w_\pm=\frac{dE_\pm}{db}=\frac12\left[1\pm\frac{b+A/2}{\sqrt{(b+A/2)^2+2A^2}}\right].\]

The weights sum to one as required by completeness. At zero field they are \(2/3\) and \(1/3\). At large positive field the upper line takes almost all this polarisation strength. In the negative block an analogous derivative with respect to \(-b\) gives the population of \(|0,\downarrow\rangle\). At its avoided crossing each eigenstate has equal weights and the two corresponding \(q=0\) intensities are equal for a selected initial spin down. The same experiment can test slopes measured from frequencies and overlaps measured through intensities, provided detection and radial coupling are common to both lines.

Set \(b=A\) in the positive block. The level separation becomes \(A\sqrt{4.25}=2.06155A\), while the upper product weight is \(0.8638\). A naive extrapolation of the weak-field \(g_jm\) slopes would give an interval \(1.5A+A/3=1.833A\). The discrepancy is governed by the spin–orbit mixing scale rather than failure of the magnetic Hamiltonian itself. If the frequency analyser resolves only a single intensity-weighted centroid, completeness still constrains the first moment:

\[\sum_\pm w_\pm E_\pm=\langle0,\uparrow|H_+|0,\uparrow\rangle=b.\]

Thus the centroid of unresolved lines in this ideal selected excitation can move linearly even while each constituent bends.

Resolve a second angular-momentum hierarchy with the same algebra

The \(p\)-manifold example coupled orbital and electronic spin. In an \(s\)-state atom the dominant remaining weak angular coupling may be between an electronic \(J=1/2\) and a nuclear \(I=1/2\). This is a different scale and a different physical pair of degrees of freedom. To illustrate how a state label changes with field, take

\[H=\frac{A_h}{\hbar^2}\mathbf I\cdot\mathbf J+\frac B\hbar(g_J\mu_B J_z-g_I\mu_N I_z)\]

with positive hyperfine constant \(A_h\) and a positive model nuclear \(g_I\). The minus before the nuclear-magneton term reflects the assumed positive nuclear magnetic moment. Actual sign and \(g\)-factor depend on the isotope. Here both \(A_h\) and the products of magnetic moments and field have energy units. At zero field the electronic and nuclear angular momenta combine to \(F=0,1\). Their scalar-product shifts are \(-3A_h/4\) and \(+A_h/4\), respectively. A rotation of the entire coupled system leaves this zero-field Hamiltonian invariant, but independent rotations of just one constituent generally do not.

Within \(m_F=0\) order the product basis by electronic magnetic sign as \(|\uparrow_J,\downarrow_I\rangle,|\downarrow_J,\uparrow_I\rangle\). Both diagonal hyperfine matrix elements are \(-A_h/4\), off-diagonal exchange is \(A_h/2\), and field changes the diagonal difference by \(\delta=(g_J\mu_B+g_I\mu_N)B\). Hence the central pair of energies is

\[E_\pm=-A_h/4\pm\tfrac12\sqrt{A_h^2+\delta^2}.\]

The two stretched \(m_F=\pm1\) levels sit at \(+A_h/4\pm(g_J\mu_B-g_I\mu_N)B/2\). Their slopes contain a difference of electronic and nuclear moments, while the central splitting depends on their sum. This sign distinction can be determined directly by comparing the relevant product states: in the anti-aligned pair the sign change reverses one angular momentum along with its opposite magnetic sign. A sign convention imported from electron spin alone would give an erroneous nuclear contribution.

The transition between the two central states has gap \(\sqrt{A_h^2+\delta^2}\) and zero linear slope at \(B=0\). Its quadratic shift is \(\delta^2/(2A_h)\) for \(|\delta|\ll A_h\). Measuring at a point with zero first derivative reduces sensitivity to slow field fluctuations without eliminating it. Suppose \(A_h/h=1.00\) GHz and \((g_J\mu_B+g_I\mu_N)/h=28.0\) GHz/T in an illustrative species model. At a 1.0 mT bias the central gap rises by about 0.392 MHz. A 1 μT field error at that bias gives a first-order frequency error of about 784 Hz using the derivative of the quadratic expansion. At zero mean bias, fluctuations with rms 1 μT instead give an average quadratic shift about 0.392 Hz. Stabilising the field mean and reducing its variance address different terms in the measured spectral position.

The magnetic drive operator for a small oscillating field along \(z\) is itself proportional in this block to \(\sigma_z\). At zero bias the hyperfine eigenstates are the symmetric and antisymmetric superpositions, so this drive couples them off-diagonally despite the central transition frequency being stationary against a small static bias. The diagonal derivative and the off-diagonal transition matrix element are distinct quantities. At large bias the eigenstates approach product states and the same longitudinal drive becomes mostly diagonal, reducing its ability to flip between them. Thus a transition can have both a vanishing first-order shift and a nonzero resonant driving strength, consistent with the same Hamiltonian. Measuring both properties probes the field dependence of eigenvectors as well as eigenvalues.

Infer a field distribution from widths and centres

Spectra of spatially extended samples often contain a distribution of static magnetic fields. Consider a single weak-field transition with frequency \(\nu(B)=\nu_0+sB\), an intrinsic Gaussian line standard deviation \(w_0\), and a sample field distributed approximately Gaussian with mean \(B_0\) and standard deviation \(\sigma_B\). A sum over independent source regions convolves the intrinsic line with the frequency distribution generated by \(sB\). The observed centre is \(\nu_0+sB_0\), and variance is \(w_0^2+s^2\sigma_B^2\). A single linewidth cannot determine both an intrinsic width and a field inhomogeneity. Two lines with different known magnetic slopes or one calibrated zero-slope reference can separate the contributions.

For example two transitions with slopes 7.0 and 14.0 GHz/T have measured standard deviations 0.250 and 0.400 MHz. Subtract the squared widths to eliminate \(w_0^2\):

\[\sigma_B^2=\frac{(0.400)^2-(0.250)^2}{(14000)^2-(7000)^2}\ \mathrm{T^2},\]

using MHz/T in the denominator. The result is \(\sigma_B=25.8\,\mu\mathrm T\), and the inferred intrinsic width is

\[\sqrt{0.250^2-(7000\sigma_B)^2}=0.173\,\mathrm{MHz}.\]

A third line with slope near zero supplies an out-of-sample check. If lines have significantly different lifetimes or power broadening, the assumption of a common \(w_0\) should be relaxed; otherwise one can spuriously infer a magnetic gradient or even a negative intrinsic variance.

For a curved avoided-crossing line expand \(\nu(B)\simeq\nu(B_0)+s(B-B_0)+q(B-B_0)^2/2\). A symmetric distribution shifts the measured mean by \(q\sigma_B^2/2\) even when the mean field is known exactly. Near a stationary point the leading field broadening can be strongly asymmetric because a squared Gaussian variable has a one-sided distribution around its minimum. Fitting a symmetric line at such a point can shift its apparent peak or centre according to the fitting convention. This effect is especially relevant when locating a minimum gap from spectra at several nominal fields. A model integrating intensities over a measured spatial field distribution can be better constrained than independent fits of Gaussian centres, because all lines share the same underlying field profile.

An independent geometric test tilts the weak sensing light relative to the magnetic axis. For equal populations, a truly scalar average over all polarisations and emitted directions is insensitive to this coordinate change, but a selected \(q\) transition changes strength according to the decomposition of the laboratory polarisation. If a peak attributed to frequency splitting mainly changes its fitted centre while unresolved component intensities redistribute, some of its apparent shift may be an intensity-weighted centroid effect. Record spectra at two orthogonal polarisations, fit the same physical energy parameters and allow the predicted angular strengths to vary. A common energy correction that survives the intensity change carries a different interpretation from a change in the mixture of unresolved substates.

Predict state transfer during a field sweep

The negative-\(m\) avoided crossing of the \(p\) manifold also poses a time-dependent question. Does a changing field keep the atom in the instantaneous energy eigenstate, or in approximately the same product state? In the local two-state description subtract the trace and write \(H=(\Delta(t)/2)\sigma_z+g\sigma_x\), where the difference of diabatic diagonal energies is \(\Delta\) and the minimal adiabatic gap is \(2|g|\). Introduce a mixing angle \(\tan(2\vartheta)=2g/\Delta\), chosen continuously through the crossing. Differentiating at fixed \(g\) gives

\[|\dot\vartheta|=|g\dot\Delta|/(\Delta^2+4g^2).\]

The moving eigenbasis itself couples the two instantaneous energy states with an energy scale \(\hbar|\dot\vartheta|\).

At closest approach the order-of-magnitude adiabatic criterion becomes \(\hbar|\dot\Delta|/(8g^2)\ll1\). A slow sweep keeps occupation on an energy branch, which changes its product character across the avoided crossing. A fast sweep can leave the original product state approximately unchanged, moving population from one instantaneous energy branch to the other. Both descriptions refer to actual state transfer; the basis in which “remaining in the same state” is assessed is part of the observable. The criterion here follows directly by comparing the nonadiabatic derivative coupling with the instantaneous level separation. It estimates a regime but does not by itself give a transition probability.

For a strictly linear detuning passing from large negative to large positive values with constant \(g\), the Landau–Zener result gives the diabatic survival probability \(P_D=\exp[-2\pi g^2/(\hbar|\dot\Delta|)]\). Its applicability requires asymptotic start and end detunings well outside the coupling region, coherent passage and the indicated linearity over the crossing. In ordinary-frequency units take \(g/h=20\) kHz and \(|d(\Delta/h)/dt|=1.0\times10^{10}\ \mathrm{Hz/s}\). The exponent is \(4\pi^2(2.0\times10^4)^2/10^{10}=1.58\), giving \(P_D\simeq0.206\). Doubling the sweep rate halves the exponent and raises survival to about 0.454. Confusing angular with ordinary frequency in this conversion loses a factor \(2\pi\), large enough to change the predicted population qualitatively.

A double sweep forms a useful control. On entering and later leaving the avoided crossing, the two amplitudes propagated along different energy branches can accumulate different phases and interfere. Treating the two passages as independent classical jumps would miss oscillations versus waiting time between them. Strong dephasing or averaging over a broad field distribution can remove the oscillations while retaining the one-pass populations. Distinguish these mechanisms by calibrating single-passage transfer first and then varying the waiting time over several periods at multiple sweep speeds. This extends a static magnetospectroscopy model to a specified dynamical experiment without inferring the full time dependence from a static level diagram alone.

Resolve the crossover from coupled to uncoupled angular momenta

Scan the magnetic field across the spin–orbit scale. Compare the exact two-state spectrum at fixed magnetic quantum number with the weak-field shifts.

Test the orientation of a magnetic sensor from resolved spin populations

The scalar energy spectrum of an isotropic spin-\(1/2\) Zeeman Hamiltonian measures field magnitude. A transition energy by itself cannot determine the signed orientation of that field. Let \(H=\hbar\gamma\mathbf B\cdot\boldsymbol\sigma/2\), with signed angular gyromagnetic ratio \(\gamma\) defined in the experiment. Its eigenvalues are \(\pm\hbar|\gamma||\mathbf B|/2\). If instead one prepares spin up along a known laboratory \(z\) direction and observes its population after evolution time \(t\), the rotation axis appears in the dynamics. Exponentiating \(U=\cos(\omega t/2)I-i\sin(\omega t/2)\hat{\mathbf B}\cdot\boldsymbol\sigma\) for a consistent choice of \(\omega,\hat{\mathbf B}\) gives

\[P_{\downarrow z}(t)=(1-\hat B_z^2)\sin^2(\gamma|\mathbf B|t/2).\]

The oscillation frequency gives magnitude and its contrast gives the squared transverse fraction. It is insensitive to whether the field points slightly above or below a perpendicular plane. Incomplete preparation or pulse contrast can also reduce the observed oscillation amplitude. A calibration with a known transverse field tests that ambiguity before assigning every missing contrast to geometric tilt.

Suppose a resolved precession has angular frequency corresponding to 0.50 mT and a calibrated flip contrast of 0.36 for initial \(+z\). Then \(\sqrt{B_x^2+B_y^2}=0.30\) mT and \(|B_z|=0.40\) mT. Repeating for an initial \(+x\) state with calibrated contrast 0.64 yields \(|B_x|=0.30\) mT and thus \(B_y=0\) for these numbers. Neither experiment identifies the signs of \(B_x\) and \(B_z\). To resolve them one can measure an early-time transverse quadrature with a phase reference. In Bloch notation \(\dot{\mathbf r}=\gamma\mathbf B\times\mathbf r\), so the initially zero slope \(\dot r_y=-\gamma B_x\) for \(+z\) is sign sensitive. This derivative is independent of \(B_z\) at the initial instant, giving a direct check complementary to the energy splitting.

A second strategy adds a calibrated bias \(\mathbf b_0\) in opposite directions and examines squared frequencies. Since \(|\mathbf B+\mathbf b_0|^2-|\mathbf B-\mathbf b_0|^2=4\mathbf B\cdot\mathbf b_0\), the difference isolates a signed projection even when the zero-field splitting reveals only magnitude. For a 0.20 mT known bias along \(z\) and a 0.40 mT signed \(z\) component the squared-field difference should be \(0.32\,\mathrm{mT}^2\). Alternating the two bias signs across the measurement reduces slow field drift. A quadratic diamagnetic response, anisotropic \(g\) tensor or an uncalibrated bias axis can break this simple inversion; repeating in three independent directions tests the vector model and reveals which assumptions are being used.

Separate an anisotropic magnetic response from an unknown field direction

A crystal-fixed effective spin has diagonal \(g=\operatorname{diag}(2.0,2.0,2.4)\). Derive the transition energy for a field rotated in the \(x,z\) plane by angle \(\theta\) from \(z\), and explain what an isotropic fit would infer.

Derive and check the result

The Hamiltonian is \(\mu_B\boldsymbol\sigma\cdot(g\mathbf B)/2\). The splitting is \(\mu_B B\sqrt{2.0^2\sin^2\theta+2.4^2\cos^2\theta}\). At \(45^\circ\) the effective \(g\) is \(\sqrt{4.88}=2.209\); interpreting the measured splitting with constant \(g=2\) would overestimate field magnitude by about 10.5%. The spin also precesses around the effective axis \(g\mathbf B\), whose polar angle satisfies

\[\tan\theta_{\rm eff}=(2.0/2.4)\tan\theta.\]

Measuring contrast from a calibrated spin preparation and rotating a field of known magnitude can therefore distinguish material anisotropy from a simple error in magnet alignment. One scalar spectral line at an unknown orientation cannot separate these effects.

Tutorial · reconstruct a magnetically mixed spectrum

Infer the coupling from an anticrossing

The two negative-\(m\) lines exhibit a minimum frequency separation of 11.31 GHz at 0.286 T. Infer \(A/h\) from each measurement. What calibration would be needed for a comparison of absolute optical line frequencies?

Work through the solution

Minimum gap divided by \(h\) equals \(\sqrt2 A/h\), giving \(A/h=8.00\) GHz. The crossing condition \(b=A/2\) gives

\[A/h=2(13.996)(0.286)=8.01\,\mathrm{GHz}.\]

Their agreement checks field calibration independently of a common frequency reference. Both final states must be viewed from the same initial state when using their frequency difference. Comparing absolute optical frequencies also requires the zero-field transition energy and the field-dependent initial-level shift. Two lines originating in different initial states would have a field-dependent separation even if their final levels had a fixed interval.

Extract the polarisation weight using a finite difference

Near \(b=A\), estimate the slope of the upper positive-\(m\) level using its exact values at \(b/A=0.95,1.05\). Compare with the exact weight and predict the second line's strength.

Work through the solution

In units of \(A\) the upper level is \((t-0.5+\sqrt{(t+0.5)^2+2})/2\) with \(t=b/A\). Subtracting the values and dividing by 0.10 gives about 0.864. The analytical derivative is

\[[1+1.5/\sqrt{4.25}]/2=0.8638.\]

The second line carries 0.1362 of the total angular strength. Halving the centred step should reduce the derivative's truncation error by about four for this smooth curve. In an experiment frequency noise per point is instead amplified as inverse step. Compare several field steps to establish a practical slope uncertainty.

Use an unresolved centroid to detect a calibration problem

At \(b=A\) a weak \(q=0\) experiment driven from a selected spin-up preparation records both positive-\(m\) final states. Its excitation-weighted centroid after restoring the initial-state energy is \(0.78A\). Could the exact two-level mixing alone produce that centroid?

Work through the solution

The sum rule requires \(b=A\). Direct calculation gives energies approximately \(1.2808A\) and \(-0.7808A\); weights 0.8638 and 0.1362 give \(1.000A\) within rounding. In this model mixing alone cannot explain \(0.78A\). A missing weak line, saturation, polarisation contamination, different collected fluorescence efficiencies or a mistaken correction for the initial state can shift a measured centroid. Compare both individual integrated line areas at low intensity and reverse the field with the corresponding spin preparation. These tests use distinct symmetry and strength predictions rather than interpreting one centroid as a complete spectrum.

Further reading

Two electrons, exchange splitting and the cost of localisation

Build a two-electron state that respects exchange, derive its charge and spin correlations, and then solve a two-site model exactly. The two examples reveal when a triplet is favoured and when an apparently weak hopping lowers the singlet instead.

Construct states before introducing a force

A two-electron wavefunction has two spatial arguments and two spin labels. The labels 1 and 2 identify argument slots; they do not attach persistent tags to individual identical electrons. Exchanging all position and spin variables must multiply an electronic state by minus one. This is the fermionic exchange postulate. It constrains which vectors describe electrons even when their Hamiltonian contains no spin-dependent term. A measurement with no access to the ordering of slots is represented by an observable symmetric under the same exchange.

Let \(a(\mathbf r),b(\mathbf r)\) be normalised orthogonal spatial orbitals. The symmetric and antisymmetric spatial combinations are \(\Phi_\pm=[a(1)b(2)\pm b(1)a(2)]/\sqrt2\). Combine \(\Phi_+\) with the spin singlet \((|\uparrow\downarrow\rangle-|\downarrow\uparrow\rangle)/\sqrt2\), and \(\Phi_-\) with any of the three symmetric triplet spin states. For equal positions the antisymmetric spatial combination vanishes exactly. Its joint probability has an exchange hole at coincidence even for noninteracting same-spin fermions. When \(a=b\), the antisymmetric combination vanishes identically and only the symmetric spatial state with opposite spins in a singlet is available. Occupation of the same spatial mode by two electrons is thus compatible with the exclusion principle if the full spin orbitals differ.

For two distinct orthogonal modes, both \(\Phi_+\) and \(\Phi_-\) have the same one-particle number density \(|a(\mathbf r)|^2+|b(\mathbf r)|^2\), normalised to two electrons. To see this, integrate \(|\Phi_\pm(\mathbf r_1,\mathbf r_2)|^2\) over \(\mathbf r_2\) and multiply by two. Cross terms contain \(\langle a|b\rangle=0\). Coincidence and correlation measurements can therefore distinguish preparations that share their entire one-particle density. The spin-antisymmetric singlet can also give correlated opposite spin outcomes along any common measurement axis, while both individual spins are unpolarised. Position and spin comparisons probe different reduced descriptions of the same total state.

Separate the direct and exchange integrals

For an independent-orbital estimate take \(H=h(1)+h(2)+v(1,2)\) with \(h a=\epsilon_a a,\ h b=\epsilon_b b\), and a symmetric spin-independent repulsion. Expand the expectation of \(v\) in \(\Phi_\pm\). Diagonal terms give the same direct integral and off-diagonal terms are conjugates:

\[J_{ab}=\iint |a(1)|^2 v(1,2)|b(2)|^2\,d^3r_1d^3r_2,\qquad\]
\[K_{ab}=\iint a^*(1)b(1)v(1,2)b^*(2)a(2)\,d^3r_1d^3r_2 .\]

For Coulomb repulsion \(K_{ab}\) is nonnegative: it is the positive Coulomb quadratic form of the transition density \(a^*b\), seen for instance from its Fourier representation weighted by \(4\pi/k^2\). Orthonormality only makes the spatial integral of the transition density vanish, not its weighted self-interaction. The expectation energies are \(\epsilon_a+\epsilon_b+J_{ab}\pm K_{ab}\). In this fixed pair of spatial orbitals the triplet is lower by \(2K_{ab}\). If the orbitals have disjoint support the exchange integral vanishes, although the direct repulsion need not. A splitting caused by spatial symmetry does not require an extra microscopic spin–spin repulsive force.

Set \(J_{ab}=0.80\) eV and \(K_{ab}=0.070\) eV in an illustrative excited configuration. Its Coulomb shifts are 0.87 eV and 0.73 eV. A weighted average over all four spin states is

\[J-K/2=0.765\,\mathrm{eV}.\]

Optical line strengths generally do not populate those four spin states equally. The energy difference is a statement about this restricted configuration; another spatial occupation can place a singlet below the entire triplet manifold. Predicting a ground-state spin therefore requires admitting the competing occupations and the one-body and correlation energies they carry.

Allow hopping and double occupation

Now take two orthonormal localised orbitals \(L,R\) of equal one-body energy. A fermion hops between them at amplitude \(-t\), and placing opposite spins on the same site costs \(U>0\). Define \(H=-t\sum_\sigma(c^\dagger_{L\sigma}c_{R\sigma}+c^\dagger_{R\sigma}c_{L\sigma})+U\sum_i n_{i\uparrow}n_{i\downarrow}\). This is a specified two-site Hubbard model, not a complete microscopic Coulomb Hamiltonian. Its direct intersite exchange integral is set to zero here, so its spin ordering need not follow the fixed-orbital calculation above. Position, spin and field units enter through the experimentally or computationally determined \(t,U\).

In the two-electron sector a state with two up spins must occupy one orbital on each site. Hopping would create two up spins in one orbital and therefore annihilates this state. Rotational symmetry implies the same energy zero for all three triplets. Define the singly occupied singlet \(|S\rangle\) and symmetric doubly occupied state \(|D_+\rangle=(|\uparrow\downarrow,0\rangle+|0,\uparrow\downarrow\rangle)/\sqrt2\). A consistent fermionic ordering gives an off-diagonal \(-2t\) between them; each direction and spin contributes and the normalisations leave the factor two. Changing the phase of \(D_+\) reverses that matrix element but leaves the eigenvalues unchanged. The orthogonal antisymmetric doublon remains at energy \(U\). The relevant singlet block is

\[H_S=\begin{pmatrix}0&-2t\\-2t&U\end{pmatrix},\qquad E_{\pm}=\frac{U\pm\sqrt{U^2+16t^2}}{2}.\]

The ground energy \(E_-<0\) for \(t\ne0\). At \(U\gg|t|\) expand the square root to obtain

\[E_-\simeq-4t^2/U+16t^4/U^3+\cdots.\]

The singlet–triplet splitting \(J_{\rm eff}=E_T-E_-\simeq4t^2/U\) can be represented in the singly occupied subspace by \(J_{\rm eff}(\mathbf S_L\cdot\mathbf S_R/\hbar^2-1/4)\). The singlet can lower its energy by virtual double occupation while spin symmetry blocks the triplets. The inferred spin coupling scales as the square of hopping and inversely with the energy cost. This mechanism is commonly called antiferromagnetic superexchange.

Determine a correlation without reading an eigenvector

The fraction of probability with double occupation in the ground state is \(\langle\partial H/\partial U\rangle\). Differentiating its energy gives

\[D=\tfrac12[1-U/\sqrt{U^2+16t^2}].\]

For positive large \(U\), \(D\simeq4t^2/U^2\). Comparing the derivative with the explicit eigenvector provides a useful independent test of signs and normalisations. From \(E s=-2t d\) one obtains

\[d/s=-E/(2t).\]

Normalising gives \(D=E^2/(4t^2+E^2)\), identical to the derivative expression for either lower-branch parameter value.

For \(t=10\) meV and \(U=100\) meV, \(\sqrt{U^2+16t^2}=107.70\) meV and the exact splitting is 3.85 meV. The leading 4.00 meV expression is about 3.9% high. Double occupation is only 3.58%, yet forbidding it at the outset would predict exactly zero splitting. A virtually occupied state can matter appreciably in a low-energy Hamiltonian even when a projective charge measurement rarely finds it occupied. At \(U=0\) the ground energy is \(-2|t|\), corresponding to two opposite spins in the bonding one-electron orbital; the double-occupation fraction is one half. The large-\(U\) expression diverges as \(U\to0\) because its perturbative premise disappears. The exact two-state matrix remains finite.

Derive an effective screening charge for a helium-like ground state

A two-electron atom provides a continuous-space counterpart to the two-site model. In atomic units set \(\hbar=m_e=e^2/(4\pi\epsilon_0)=1\) and take an infinitely heavy nucleus of charge \(Z\). The nonrelativistic Hamiltonian is

\[H=\sum_{i=1}^2[-\nabla_i^2/2-Z/r_i]+1/r_{12}.\]

The two one-electron ground orbitals may be identical in space because opposite spins can form an antisymmetric singlet. Use a trial product of two normalised hydrogenic functions \(u_\zeta(\mathbf r)=(\zeta^3/\pi)^{1/2}e^{-\zeta r}\) with a variable positive exponent \(\zeta\). This single parameter lets the spatial cloud expand in response to mutual repulsion. Choosing the exponent equal to \(Z\) without testing it would impose the noninteracting size on an interacting problem.

A single orbital gives \(\langle-\nabla^2/2\rangle=\zeta^2/2\) and \(\langle1/r\rangle=\zeta\), either by direct integration or by hydrogenic scaling. Two electrons thus contribute \(\zeta^2-2Z\zeta\) to the expectation. To derive the repulsion term, average \(1/|\mathbf r_1-\mathbf r_2|\) over two independent uniform angles at fixed radii. Gauss's shell result, or a direct change of variable in the angular integral, gives \(1/\max(r_1,r_2)\). The radial probability is

\[P(r)=4\zeta^3r^2e^{-2\zeta r}.\]

Symmetry between the two electron labels permits restricting one integral to \(r_2<r_1\), then doubling:

\[J=2\int_0^\infty \frac{P(r)}r\,dr\int_0^r P(s)\,ds,\]
\[\int_0^rP(s)ds=1-e^{-2\zeta r}(1+2\zeta r+2\zeta^2r^2).\]

The first part of the resulting \(r\) integral gives \(2\zeta\). The three exponential subtraction terms sum to \(11\zeta/8\), leaving \(J=5\zeta/8\). Their evaluation uses \(\int_0^\infty r^ne^{-a r}dr=n!/a^{n+1}\). Both the dependence linear in \(\zeta\) and the positive sign follow from scaling an inverse-distance repulsion; only the numerical coefficient needed the angular and radial integration. Replacing the expectation of \(1/r_{12}\) by \(1/\langle r_{12}\rangle\) would generally give a different coefficient because inverse distance is nonlinear.

Consequently \(E(\zeta)=\zeta^2-2(Z-5/16)\zeta\) is an upper bound on the ground energy. It minimises at \(\zeta_*=Z-5/16\), with \(E_{\rm var}=-(Z-5/16)^2\) hartree for positive \(\zeta_*\). For helium \(Z=2\), \(\zeta_*=1.6875\), giving \(-2.84766\) hartree, compared with \(-2.75\) hartree at \(\zeta=2\). The one-electron ion has energy \(-2\) hartree, so this variational value lies below the threshold for an electron plus the ion and demonstrates binding within the model. The trial ionisation energy \(0.84766\) hartree is a lower bound on the exact ionisation energy when that threshold is known exactly. An upper bound on the neutral energy gives a lower bound on the energy required to remove an electron.

The interpretation of \(5/16\) as a screening correction is limited. At short radii each electron feels nearly the full nuclear singularity, while far outside it sees the remaining net charge. One constant exponent cannot reproduce both limits and cannot describe how the two electron positions avoid one another at fixed one-particle radius. The product trial permits nonzero joint weight at electron coincidence. Multiplying by a factor involving \(r_{12}\) introduces genuine correlation beyond independent orbitals. Optimising a broader variational family containing this product can only lower or retain the variational energy, provided its integrals and normalisation are computed consistently. Monitoring energy together with the pair-separation distribution tests whether the enlargement captures the physics of repulsion rather than merely adjusting a one-body radius.

Infer a local two-electron boundary condition from the Coulomb singularity

Near coincidence of two unlike-spin electrons, the Coulomb repulsion diverges like \(1/r_{12}\). The wavefunction itself can remain finite at coincidence, but its derivative must cancel this singularity in the Schrödinger equation. Consider a fixed smooth centre coordinate and average the wavefunction over the direction of the interelectron separation \(r\), away from simultaneous nuclear coincidence. Assume an expansion \(\bar\Psi(r)=A+Br+\cdots\). In atomic units the reduced mass is one half, so the relative spherical kinetic operator is \(-[d^2/dr^2+(2/r)d/dr]\) for the locally \(s\)-wave part. Its leading singular term is \(-2B/r\). Adding \(\bar\Psi/r\) gives coefficient \(A-2B\) of \(1/r\). A finite energy eigenvalue requires this coefficient to vanish:

\[\left.\frac{d\bar\Psi}{dr}\right|_{0}=\frac12\,\bar\Psi(0).\]

The positive cusp slope means the spatial amplitude rises as the electrons move apart from contact, consistent with repulsion. The corresponding electron–nucleus cusp has opposite sign and coefficient set by the nuclear charge and reduced mass. In a same-spin state the scalar contact amplitude vanishes by antisymmetry; this \(s\)-wave formula becomes \(0=0\) and a leading higher-partial-wave analysis is needed. Forgetting either angular averaging or exchange symmetry can turn an instructive local condition into a false statement about every directional derivative of every wavefunction.

A product of independent \(1s\) orbitals is smooth in \(r_{12}\) at a generic fixed centre and has no required linear cusp in the spherical average. A trial factor \(1+r_{12}/2\) in atomic units can impose the first-order unlike-spin cusp while leaving additional variational freedom to model long-range behaviour. Merely enforcing the cusp does not solve the entire two-electron problem. It constrains a local ratio of derivative to value, while energy depends on a six-dimensional integral. In variational Monte Carlo one can diagnose this distinction through the local energy \(H\Psi/\Psi\) near coincidence. A cusp-mismatched trial may have a singular local energy even though the volume element \(r^2dr\) keeps its integrated average finite. Imposing the cusp can reduce variance and improve short-distance pair observables more dramatically than it changes the energy expectation.

Use one-body occupation measurements to detect missing correlations

A single determinant of orthonormal spin orbitals \(\chi_i\) has a one-particle reduced density matrix \(\gamma=\sum_{\rm occupied}|\chi_i\rangle\langle\chi_i|\), normalised to the electron number \(N_e\). Thus \(\gamma^2=\gamma\) and its eigenvalues are zero or one. This is an algebraic signature of a single pure Slater determinant in the spin-orbital convention. For a correlated pure fermion state, natural occupations can become fractional while remaining between zero and one and summing to \(N_e\). Ensemble mixing can produce fractional occupations too, so knowing whether the entire state is pure matters if one wants to interpret fractional one-particle populations as evidence of correlation.

Consider the normalised two-electron singlet \(|\Psi\rangle=\sqrt{0.8}\,|a\uparrow,a\downarrow\rangle+\sqrt{0.2}\,|b\uparrow,b\downarrow\rangle\), with each ket a determinant. A one-body operator changes at most one occupied spin orbital, so its matrix element between these two doubly different determinants vanishes. The four natural spin-orbital occupations are \(0.8,0.8,0.2,0.2\). Their sum is two while \(\operatorname{tr}\gamma^2=1.36\), smaller than the determinant value two. An incoherent mixture of the two determinants at the same weights has the same one-body matrix, although it no longer has their joint coherence. A two-body pair-transfer operator that converts both \(a\) electrons into \(b\) electrons, plus its adjoint, can reveal a relative phase between these branches. Thus a complete one-body spectrum still need not determine a two-body state.

The symmetric Hubbard dimer ground state has another direct relation between energy derivatives and its one-body coherence. Let \(T=\sum_\sigma(c^\dagger_{L\sigma}c_{R\sigma}+c^\dagger_{R\sigma}c_{L\sigma})\). The energy derivative gives

\[\langle T\rangle=-\partial E_-/\partial t=8t/\sqrt{U^2+16t^2}.\]

At \(U=0\) and \(t>0\), \(\langle T\rangle=2\) because both electrons occupy the bonding orbital. At large \(U/t\) this coherence approaches zero even though the exact finite-\(t\) ground state remains a total spin singlet. In the bonding/antibonding spatial basis, the sum of both populations is two and their difference is \(\langle T\rangle\). For the example \(U=100,\ t=10\) meV this gives spatial occupations roughly 1.371 and 0.629. Dividing by two gives the spin-orbital occupations for each spin in this singlet. Site populations alone are one on each site by symmetry at every \(U/t\); their apparent constancy completely misses this changing form of correlation.

Break site symmetry and measure the onset of charge transfer

Add a static site-energy imbalance with energies \(-\Delta/2\) on \(L\) and \(+\Delta/2\) on \(R\). The singly occupied configuration still has total site energy zero, while double occupations cost \(U-\Delta\) and \(U+\Delta\). For \(|t|\ll U-|\Delta|\) the singly occupied singlet gains the second-order shift \(-2t^2/(U-\Delta)-2t^2/(U+\Delta)\), since its matrix element to either double occupation has magnitude \(\sqrt2|t|\). The triplets remain blocked. The effective exchange splitting is \(4t^2U/(U^2-\Delta^2)\). At zero imbalance it reduces to the earlier \(4t^2/U\); small imbalance changes it quadratically, consistent with exchanging left and right sites.

For \(U=100,\ t=5,\ \Delta=40\) meV, the estimate gives \(1.19\) meV compared with \(1.00\) meV at zero bias. Increasing imbalance can make one virtual double occupation especially inexpensive, changing the gap before the mean site charge substantially relocates. Near \(\Delta=U\) the denominator vanishes and the perturbative model predicts a divergence. The true three-state singlet matrix instead has an avoided crossing of singly and doubly occupied configurations. A sweep through that region should retain both double occupations and compute site charge from \(-2\,\partial E/\partial\Delta\), with the sign matched to the specified imbalance. Here an apparent runaway effective spin coupling marks the failure of eliminating charge degrees of freedom, rather than an arbitrarily large spin energy in the actual finite Hamiltonian.

Measure singlet–triplet exchange without a spin force

Change the on-site repulsion in a two-electron dimer. Check whether exchange inferred from the spectrum follows the virtual-hopping estimate.

See exchange interference directly in a two-port experiment

A lossless balanced beam splitter for two orthonormal single-particle modes can be chosen to act on creation operators as \(a^\dagger\to(c^\dagger+d^\dagger)/\sqrt2,\ b^\dagger\to(c^\dagger-d^\dagger)/\sqrt2\). Bring two identical particles to the device, one per input, with wave-packet timing and internal states controlled. The input \(a^\dagger b^\dagger|0\rangle\) contains no explicit interaction. Nevertheless the coincidence statistics after the device depend on exchange because two paths can lead to the same unordered output configuration. This provides a way to test exchange far from the Coulomb energy calculations of the previous sections.

For identical spinless bosons multiply the two sums and use commuting creation operators. The cross terms cancel, leaving \([(c^\dagger)^2-(d^\dagger)^2]|0\rangle/2=(|2,0\rangle-|0,2\rangle)/\sqrt2\). Both particles leave the same port and coincidence probability vanishes. The \(\sqrt2\) in a normalised doubly occupied Fock state is essential. For identical fermions in the same internal state the repeated creation terms vanish and the cross terms add because \(d^\dagger c^\dagger=-c^\dagger d^\dagger\). The outgoing state has one particle in each port with unit probability. Neither result requires an attractive or repulsive force at the splitter. Their interpretation turns on whether the alternatives remain indistinguishable and on the symmetry of the total input.

Now give the two particles internal wave packets \(|u\rangle,|v\rangle\), which may encode time, frequency or spin, and suppose the detectors report output ports but do not resolve internal labels. One coincidence alternative puts \(u\) in \(c\) and \(v\) in \(d\); the other interchanges them. The interference cross term contains the product \(\langle u|v\rangle\langle v|u\rangle=|\langle u|v\rangle|^2\). At a balanced splitter the coincidence probability is \([1-|\langle u|v\rangle|^2]/2\) for initially independently prepared bosons and \([1+|\langle u|v\rangle|^2]/2\) for corresponding fermions. At zero overlap both reduce to one half, as expected for two distinguishable independent particles each taking a random output.

Take transform-limited Gaussian wavepacket intensities of common time variance \(\sigma_t^2\) with delay \(\tau\) between their centres and no carrier mismatch. Integrating their two normalised amplitude envelopes gives

\[|\langle u|v\rangle|^2=\exp[-\tau^2/(4\sigma_t^2)].\]

For \(\sigma_t=0.50\) ps and delay 1.00 ps this is

\[e^{-1}=0.368.\]

The predicted bosonic coincidence fraction is 0.316 and the fermionic value 0.684. A narrow time gate can itself identify the particles differently at different delays and must be included in the counting model. Measuring the single-output rates together with coincidences tests splitter balance and detection bias before converting dip or peak contrast into an overlap estimate.

Infer distinguishability with an unbalanced splitter

A calibrated splitter has intensity transmittance \(T=0.60\), reflectance \(R=0.40\) and negligible loss. Two photons from separate inputs give coincidence probability 0.184 at equal central arrival time. Infer their internal squared overlap. Would equal-time arrival alone have guaranteed perfect bunching?

Derive and check the result

For indistinguishable paths the two coincidence amplitudes have opposite signs with magnitudes \(T,R\). A nonresolving detector gives

\[P_c=T^2+R^2-2TR|\langle u|v\rangle|^2.\]

Substitution yields squared overlap \((0.52-0.184)/0.48=0.70\). Even perfect internal overlap at this unbalanced splitter would leave \((T-R)^2=0.040\) coincidences. Equal arrival time controls only one possible distinguishing label; orthogonal polarisation or spectral mismatch can still reduce overlap. A far-delay reference should give \(T^2+R^2=0.52\) for distinguishable, otherwise comparable photons. This independent control helps separate exchange interference from lost counts or a miscalibrated splitter.

Tutorial · discriminate spatial exchange from virtual hopping

Normalise two nonorthogonal orbitals before predicting coincidences

Let \(a,b\) each have norm one but overlap \(s=0.30\). Find the normalisations of their symmetric and antisymmetric products. Does the antisymmetric state still vanish at common position?

Work through the solution

The inner product \(\langle ab|ba\rangle=|s|^2=0.09\). The normalisation denominators are

\[\sqrt{2(1+0.09)}=1.476,\]
\[\sqrt{2(1-0.09)}=1.349.\]

At identical positions the antisymmetric numerator cancels pointwise for every \(s\). When the orbitals become identical its norm tends to zero and there is no independent antisymmetric state of that pair. For nonzero overlap the one-body cross terms in the earlier density calculation no longer integrate away, so those equal-density formulas must be rederived. Orthonormalising local orbitals changes the parameters of a corresponding Hubbard model as well.

Infer a hopping amplitude from a measured singlet gap

A calibrated two-site sample has \(U=120\) meV and a singlet–triplet gap 5.0 meV. In the model above find \(t\) exactly, predict the double-occupation probability and compare with a large-\(U\) inference.

Work through the solution

Writing \(J=(\sqrt{U^2+16t^2}-U)/2\) gives \(4t^2=J(U+J)\), hence \(|t|=12.50\) meV. The large-\(U\) estimate \(\sqrt{JU}/2=12.25\) meV is close but measurably different. The double-occupation fraction is

\[\tfrac12[1-U/(U+2J)]=J/(U+2J)=0.03846.\]

Gap alone cannot distinguish signs of \(t\) in a two-site model because rephasing one orbital reverses the sign. Measuring charge fluctuations independently tests whether the observed spin gap can be explained by this same virtual process.

Predict coherent double-occupation oscillations

Start suddenly in the singly occupied singlet of the symmetric two-site model. Find the probability of observing either doubly occupied site after time \(\tau\) and its maximum at \(U=100,\ t=10\) meV. Predict the triplet control.

Work through the solution

Subtract \(U/2\) times identity from the two-dimensional Hamiltonian. The traceless matrix squares to \((U^2+16t^2)I/4\). Exponentiating gives

\[P_D(\tau)=16t^2\sin^2[\sqrt{U^2+16t^2}\,\tau/(2\hbar)]/(U^2+16t^2).\]

Its maximum is

\[1600/11600=0.138.\]

This is larger than the ground-state admixture because the sudden preparation is a coherent superposition of both energy eigenstates. A triplet evolves with no doubly occupied component in this ideal Hamiltonian. Observing double occupation after triplet preparation would test spin mixing, state-preparation fidelity or additional orbitals.

Further reading

From a finite pulse to a continuum transition rate

Switch a weak perturbation on for a measured duration. Its Fourier transform determines the amplitude of a discrete transition. Summing over a dense set of final states reveals where a time-independent transition rate comes from and where it fails.

Remove the known free evolution before approximating

Let \(H_0|n\rangle=E_n|n\rangle\) and \(H(t)=H_0+V(t)\). Expand \(|\psi(t)\rangle=\sum_n c_n(t)e^{-iE_n t/\hbar}|n\rangle\). Substituting into the time-dependent Schrödinger equation cancels the free phase derivatives and leaves an exact equation \(i\hbar\dot c_f=\sum_n e^{i(E_f-E_n)t/\hbar} V_{fn}(t)c_n(t)\). Suppose the initial state is \(|i\rangle\) and the perturbation is appreciable only between \(0\) and \(T\). Iterating the integral equation once, replacing \(c_n(t)\) on the right by \(\delta_{ni}\), yields

\[c_f^{(1)}(T)=-\frac i\hbar\int_0^T e^{i\omega_{fi}t}V_{fi}(t)\,dt,\]
\[\omega_{fi}=(E_f-E_i)/\hbar .\]

For \(f\ne i\) the leading transition probability is \(|c_f^{(1)}|^2\). It is second order in the perturbation even though the amplitude is first order. Conservation of total probability to this order requires a second-order correction to the initial amplitude. Simply appending all positive final probabilities while keeping the initial probability exactly one would fail that test. The approximation is controlled when total probability removed from the initial state is small over the observation duration and higher-order pathways are negligible.

Let the resonant component of a drive have matrix element \(V_{fi}(t)=v e^{-i\omega t}\) for \(0<t<T\). For a real cosine perturbation the two exponentials each carry half the real peak amplitude, so \(v\) refers to just the near-resonant part. Define \(\Delta=\omega_{fi}-\omega\). Direct integration gives

\[P_f^{(1)}=\frac{|v|^2T^2}{\hbar^2}\operatorname{sinc}^2(\Delta T/2),\]
\[\operatorname{sinc}x=\sin x/x .\]

At resonance the amplitude grows linearly in time while its phase remains coherent. A detuned contribution winds around in the complex plane and largely cancels. The first zeros occur at ordinary detuning \(\pm1/T\) in hertz. The full width at half height is approximately \(0.886/T\) in ordinary frequency since \(\sin x/x=1/\sqrt2\) at \(x\simeq1.3916\). Doubling duration quadruples the line-centre probability for one final state but halves the linewidth, a distinction central to interpreting a continuum rate.

Sum over final states before taking a long-time limit

A large box provides a discrete set of final levels with spacing \(\delta E\); at fixed finite time many can lie inside the pulse's energy bandwidth. Let \(\rho(E)\) be the density of the accessible final states per joule, including degeneracy exactly once. Replace the sum by an integral with \(E_*=E_i+\hbar\omega\):

\[P_{\rm out}\simeq\frac{T^2}{\hbar^2}\int dE\,\rho(E)|v(E)|^2\operatorname{sinc}^2\left[\frac{(E-E_*)T}{2\hbar}\right].\]

If \(\rho|v|^2\) changes little across the dominant width and the line is well away from thresholds, take it outside the integral. Substitute \(u=(E-E_*)T/(2\hbar)\), and use \(\int_{-\infty}^{\infty}(\sin u/u)^2du=\pi\). The area of the squared Fourier transform grows linearly, giving

\[\Gamma=\frac{P_{\rm out}}T\simeq\frac{2\pi}{\hbar}|v(E_*)|^2\rho(E_*).\]

The identity for the sinc area also follows by Parseval from the energy in the rectangular time window. This is Fermi's golden rule with \(\rho\) per energy. If a supplied density is per unit angular frequency,

\[\rho_\omega=\hbar\rho_E;\]

failing to change that measure introduces a factor of \(\hbar\). The units are a strong check: energy squared times states per energy divided by action is inverse seconds.

Several limits have been taken in a definite order. The perturbation lasts long enough to resolve the scale on which \(\rho|v|^2\) varies but short enough that many levels still fit in its bandwidth. A window of times must exist between a reservoir correlation time and a recurrence time of order \(2\pi\hbar/\delta E\). In addition \(\Gamma T\ll1\) for the first-order depletion argument. Taking \(T\to\infty\) at fixed finite box instead resolves individual levels and can produce coherent oscillations or recurrences. Extending the constant rate to a full exponential decay uses a further memoryless approximation and renewed weak transitions of the remaining population. A linear short-time fit by itself does not establish exponential dynamics at every time.

Keep matrix elements and density normalisation consistent

For illustration choose \(|v|=5.00\times10^{-6}\) eV and \(\rho=20.0\ \mathrm{eV^{-1}}\) for box-normalised accessible modes dense enough on the pulse scale, giving \(\Gamma\simeq4.77\times10^6\,\mathrm{s^{-1}}\) as a formal product. But the implied mean level spacing \(1/\rho=0.050\) eV corresponds to a recurrence scale of only \(8.27\times10^{-14}\) s. Using a nanosecond pulse with this literal finite density violates the continuum criterion, irrespective of how small \(\Gamma T\) looks. This numerical mismatch is a useful trap: reproducing a golden-rule number to many digits does not ensure the system supports irreversible decay in the chosen time range.

Now enlarge the quantisation volume by \(10^6\) for continuum-normalised physical coupling. The number of accessible states per energy grows by \(10^6\), while each squared matrix element shrinks by \(10^6\) for a localised initial state and individually unit-normalised extended final states. The same product gives the same \(\Gamma\), but spacing is now \(5.0\times10^{-8}\) eV and the recurrence scale 82.7 ns. At \(T=2.0\) ns, \(\Gamma T=0.00954\) and roughly \(h/(T\delta E)\simeq41\) spacings fit up to the first positive zero. Whether density and coupling are locally smooth on that bandwidth remains an additional condition. The scaling removes explicit box dependence from a physical rate while clarifying why direct sums at finite volume can require larger spaces.

Use phase space to predict the shape of a continuum edge

For free relative motion in three dimensions, count single scalar internal channels in a cubic periodic volume \(\mathcal V\). One state occupies volume \((2\pi)^3/\mathcal V\) in wave-vector space. The shell between \(k,k+dk\) thus contains \(\mathcal V4\pi k^2dk/(2\pi)^3\). From \(E=\hbar^2k^2/(2m)\) it follows that \(\rho(E)=\mathcal V m k/(2\pi^2\hbar^2)\), which vanishes like \(\sqrt E\) at threshold. In one dimension the corresponding free density diverges like \(1/\sqrt E\); the geometrical shell measure is different. A threshold suppression observed in one spectrum could come from available states, the coupling matrix element, or both.

If a local transition couples chiefly to a final orbital partial wave \(l\), its regular low-\(k\) free radial factor near the source scales as \(k^l\) when the potential is sufficiently short ranged and no threshold resonance changes the law. Squaring and multiplying by the three-dimensional density gives

\[\Gamma_l\propto k^{2l+1}\propto E^{l+1/2}.\]

For a \(p\)-wave channel doubling the excess energy increases this ideal rate by \(2^{3/2}=2.83\). Long-range Coulomb fields alter the final-state radial behaviour and can invalidate the short-range threshold power. Very close to any edge a finite pulse straddles energies where the density changes rapidly or vanishes. Replace the local golden-rule product by the finite-window integral to model the measured onset.

Compare pulse shapes at equal area and equal energy

The rectangular pulse is useful because its Fourier transform is elementary. Its abrupt start and end also generate sidelobes that can excite nearby unwanted transitions. For a general narrowband drive write its resonant matrix element \(v(t)e^{-i\omega t}\). First order gives

\[P_f=|\int v(t)e^{i\Delta t}dt|^2/\hbar^2.\]

At zero detuning only the complex pulse area \(\int v(t)dt\) matters. After summing over a flat continuum, Parseval gives \(\int P_f(\Delta)d\Delta=(2\pi/\hbar^2)\int|v(t)|^2dt\), so it is the temporal integral of squared coupling that controls total spectral weight. Two pulses with the same area can have different continuum probabilities; two with the same integrated intensity can have different resonant peak heights.

For a Gaussian envelope \(v(t)=v_0e^{-t^2/(2\tau^2)}\) on the full line, complete the square in its Fourier integral. The amplitude is \(v_0\sqrt{2\pi}\tau e^{-\Delta^2\tau^2/2}\), so the transition profile has no sidelobes and has full half-height angular width \(2\sqrt{\ln2}/\tau\). The time intensity is \(|v_0|^2e^{-t^2/\tau^2}\), with temporal full half-height width \(2\sqrt{\ln2}\tau\). Multiplying this by the ordinary-frequency full width gives

\[2\ln2/\pi=0.441.\]

Replacing an amplitude width by an intensity width changes that product by \(\sqrt2\); specifying the plotted quantity is necessary when comparing a spectrum with temporal photodetector data.

Take a Gaussian with \(\tau=0.50\) ms. Its spectral intensity full width is \(530\) Hz and pulse intensity full temporal width \(0.833\) ms. An unwanted line 1.0 kHz away receives a relative first-order probability \(e^{-(2\pi1000\tau)^2}\simeq5.17\times10^{-5}\). A nominally same-duration rectangular pulse may place an ideal zero near some precisely chosen detuning, but neighbouring frequencies generally see sidelobes. Which pulse gives smaller unwanted excitation depends on what quantity is fixed, where the extra lines lie and how much uncertainty there is in their positions. A shaped envelope can suppress spectral leakage without improving every possible resolution metric.

A pair of pulses illustrates how coherently adding amplitudes differs from broadening a single envelope. Let identical, short pulses of area \(A\) be separated by start-time difference \(T_s\), and let the second have a controlled drive phase \(\phi\). At a detuning small compared with each pulse bandwidth, the amplitude is proportional to \(A[1+e^{i(\Delta T_s+\phi)}]\). Its squared magnitude has fringes \(2|A|^2[1+\cos(\Delta T_s+\phi)]\) inside the broader single-pulse line. Their ordinary-frequency spacing \(1/T_s\) can be much smaller than the inverse individual pulse duration. Randomising the relative phase removes fringes while keeping the two single-pulse energies unchanged. The observed fine spectral structure is therefore a measurement of coherent time separation as well as energy difference.

Derive depletion and the energy shift from the same kernel

The first-order rate gives initial population loss in a useful time window. To see which extra assumptions allow exponential decay, retain a single initial discrete level coupled to many initially empty final levels with time-independent couplings \(v_f\) in a rotating frame. Let \(c_i(0)=1,\ c_f(0)=0\). In the interaction picture \(\dot c_f=-(i/\hbar)v_f e^{i\omega_{fi}t}c_i(t)\). Integrate this equation exactly in terms of the unknown \(c_i\) and insert the result in its partner equation for \(\dot c_i\). Assuming final levels do not couple directly to one another gives

\[\dot c_i(t)=-\int_0^t K(t-t')c_i(t')\,dt',\]
\[K(\tau)=\hbar^{-2}\sum_f |v_f|^2e^{-i\omega_{fi}\tau}.\]

No irreversibility has been assumed in this elimination. The previous discrete amplitudes are encoded in a memory kernel and can feed back into the initial level. At very short times \(c_i(t)\simeq1-K(0)t^2/2\) when the second moment is finite, yielding a quadratic survival loss. At long times a sharply structured or bounded continuum can produce nonexponential decay. A finite number of exactly known final levels evolves unitarily under the full Hamiltonian and can show recurrences; treating the memory as identically zero after any arbitrarily short interval would discard this possibility.

When the spectral coupling varies slowly over the line and extends across a sufficiently broad band, phase cancellation makes \(K(\tau)\) decay over a correlation time \(\tau_c\). For \(\tau_c\) short relative to changes in \(c_i\), write \(c_i(t-\tau)\approx c_i(t)\) inside its memory integral after the initial transient, and extend its upper limit to infinity. The regulated integral \(\int_0^\infty e^{-i\omega\tau-\eta\tau}d\tau=(\eta+i\omega)^{-1}\) tends to \(\pi\delta(\omega)-i\,\mathcal P(1/\omega)\) as a distribution. Its real part gives

\[\dot c_i=-\Gamma c_i/2+\cdots,\]

with the same golden-rule population rate \(\Gamma\). The imaginary part gives a coherent energy shift proportional to \(\mathcal P\sum_f |v_f|^2/(E_i-E_f)\), requiring the physical bandwidth and a consistent bare energy. This shows how an absorptive linewidth and a dispersive shift can emerge from different parts of the same elimination, without claiming a perfectly flat infinite continuum supplies a physically meaningful absolute shift.

For a symmetric model with constant spectral strength inside \(-W<\omega_{fi}<W\), the kernel is proportional to \(\sin(W\tau)/\tau\). Narrowing the band increases its memory time and can delay the onset of an approximately constant rate. Moving the discrete level close to a band edge also removes the cancellation between positive and negative detunings responsible for a vanishing symmetric shift. An experiment that varies the carrier across such an edge should fit the full finite-window spectrum before inferring a time-independent linewidth or level shift. A numerically cheap sum over known discrete final energies provides a check: double the spectral cutoff, halve level spacing and track the early quadratic regime separately from any intermediate exponential segment.

Ask whether frequent projective tests inhibit a transition

For an initial pure state with finite energy variance under a time-independent \(H\), expand the survival amplitude \(A(t)=\langle i|e^{-iHt/\hbar}|i\rangle\) to second order. The linear term \(-it\langle H\rangle/\hbar\) is a phase. Squaring gives

\[P_i(t)=1-(\Delta H)^2t^2/\hbar^2+O(t^3),\]

with still higher-order control depending on available moments. Define \(t_Z=\hbar/\Delta H\). In the model with one initial level coupled only off-diagonally to the final levels, \((\Delta H)^2=\sum_f|v_f|^2\), agreeing with the memory-kernel expansion. If the needed moments diverge in an idealised continuum, this short-time expansion requires a physical high-frequency regularisation.

Now make ideal instantaneous projective tests of whether the system is still in \(|i\rangle\) every \(\tau=T/N\), selecting only histories that have passed every test. Conditional on survival, each projection prepares exactly the same initial state. The joint survival probability is \(P_i(\tau)^N\simeq[1-(T/Nt_Z)^2]^N\to1\) as \(N\to\infty\) for fixed total duration \(T\). This is a mathematically precise limiting model of the quantum Zeno effect. It is not obtained by simply looking at a stored record more often after a single final measurement; the successive physical interventions reset the conditional state.

With a resonantly coupled two-state Hamiltonian \(H=v\sigma_x\), the survival against a single interval is \(\cos^2(v\tau/\hbar)\). Choose \(vT/\hbar=\pi/2\); unobserved survival at \(T\) is zero. For ten equally spaced perfect tests the joint survival is

\[\cos^{20}(\pi/20)=0.7805.\]

If the instrument has 2% independent loss per successful test, the recorded joint fraction falls to

\[0.7805(0.98)^{10}=0.638.\]

A finite-duration detector may also change \(H\) or broaden spectral coupling rather than implement an instantaneous projection. The ideal repeated-measurement result gives a comparison baseline, while predicted observed counts must include the physical instrument and conditioning.

Derive the sweep-rate scale for a transition through resonance

For a chirped weak drive let its instantaneous detuning from one discrete transition change linearly, \(\Delta(t)=\dot\Delta\,t\), crossing zero at the middle of a long pulse. The phase accumulated in the first-order integral is \(\int^t\Delta(t')dt'=\dot\Delta\,t^2/2\), not \(\Delta(t)t\). For approximately constant coupling \(v\) around the crossing and sufficiently far endpoints the oscillatory Gaussian integral gives \(|c_f^{(1)}|^2\simeq2\pi|v|^2/(\hbar^2|\dot\Delta|)\). A slower passage accumulates a larger resonant amplitude, but this weak-coupling formula cannot exceed probability one. At large transfer the full two-level avoided-crossing dynamics replaces it.

For \(|v|/\hbar=2\pi\times200\) Hz and an ordinary-frequency sweep \(d(\Delta/2\pi)/dt=10^8\) Hz/s, the estimate is \(0.0158\). Changing only the sign of the sweep gives the same first-order probability in this symmetric idealisation, while the phase of the transition amplitude changes. Coherently driving a second passage can convert that phase difference into an observable interference pattern. Missing endpoints, asymmetric pulse shaping and additional nearby lines can spoil the simple symmetry. Comparing both sweep directions and checking that the result scales as inverse speed over a low-transfer range are concrete tests of the stationary-phase approximation instead of assuming every apparent line crossing signifies complete adiabatic transfer.

Separate a transition frequency from coherence loss

Vary detuning and shot-to-shot spread while reading both pulse quadratures. Determine whether a change of population comes from a shifted carrier or a fading phase.

Derive the spectral distinction between a phase-coherent pulse and stationary noise

A fluctuating perturbation is often characterised by a power spectral density rather than a prescribed pulse phase. Suppose \(V_{fi}(t)=d_{fi}F(t)\) with \(F\) a real classical, zero-mean stationary random process and the coupling weak enough for first-order amplitudes in each realisation. Averaging the modulus squared produces a double time integral involving the autocorrelation \(C_F(\tau)=\langle F(t+\tau)F(t)\rangle\):

\[\langle P_f(T)\rangle=\frac{|d_{fi}|^2}{\hbar^2}\int_{-T}^{T}(T-|\tau|)C_F(\tau)e^{i\omega_{fi}\tau}\,d\tau.\]

The factor \(T-|\tau|\) counts the length of pairs of times in \([0,T]\) separated by \(\tau\). If \(T\) is long compared with the correlation time and depletion remains weak, divide by \(T\) to find rate \(|d_{fi}|^2S_F(\omega_{fi})/\hbar^2\), where \(S_F(\omega)=\int_{-\infty}^\infty C_F(\tau)e^{i\omega\tau}d\tau\) is the two-sided angular-frequency spectrum. No sum over a continuum of final quantum states was involved here. A continuum of drive frequencies supplies a different physical route to an approximately linear transition probability of one resolved final state.

For exponentially correlated noise \(C_F(\tau)=F_{\rm rms}^2e^{-|\tau|/\tau_c}\), integration gives

\[S_F(\omega)=2F_{\rm rms}^2\tau_c/[1+\omega^2\tau_c^2].\]

Fix \(F_{\rm rms}\) and vary correlation time. At a nonzero fixed transition frequency, extremely rapid fluctuations have little integrated spectral weight there because their fixed variance is spread over a very broad band. Very slow fluctuations concentrate their weight near zero frequency. Differentiating the spectral expression gives a maximum excitation rate at \(\tau_c=1/|\omega_{fi}|\). This nonmonotonic dependence cannot be inferred just by quoting the field's total rms amplitude. Unit conventions are also critical: changing to ordinary-frequency spectral densities and a one-sided instrument display requires the corresponding Jacobian and factor of two.

A real classical stationary process has an even spectrum \(S_F(-\omega)=S_F(\omega)\), so this model drives upward and downward transitions equally per available source population when matrix elements are conjugate. A quantum environment at thermal equilibrium can have unequal positive and negative frequency unsymmetrised spectra. Its absorption and emission probabilities encode detailed balance. Thus an observed difference between calibrated upward and downward rates cannot generally be explained by merely drawing samples from a real classical noise spectrum of the same symmetrised power. Distinguishing a driven classical source from an equilibrium quantum bath requires precise statements about which correlations enter the transition probability.

Infer a fluctuation timescale from a rate ratio

Two transitions with equal coupling strengths see the same exponentially correlated classical field at ordinary frequencies \(f\) and \(2f\). Their measured weak transition rates obey \(\Gamma(2f)/\Gamma(f)=0.40\). Infer the dimensionless correlation frequency and, for \(f=50.0\) kHz, the correlation time. What feature of the acquisition would invalidate this inference?

Derive and check the result

Let \(x=(2\pi f\tau_c)^2\). The ratio is \((1+x)/(1+4x)=0.40\), giving \(0.60=0.60x\) and \(x=1\). The correlation time is

\[1/(2\pi f)=3.18\,\mu\mathrm s.\]

At the lower frequency the noise spectrum lies at half its zero-frequency value; the higher line samples one fifth of that value. If the exposure time is comparable to or shorter than \(\tau_c\), the triangular window in the double integral still influences both rates and the infinite-time Lorentzian ratio is inadequate. Likewise unequal matrix elements or a finite observation band must be corrected separately. Measuring a third transition at another frequency supplies an independent test of the exponential-correlation model rather than simply determining its fitted timescale.

Tutorial · choose a pulse duration and check the perturbation

Measure a frequency width without confusing two line shapes

A rectangular pulse lasts 4.00 ms with resonant coupling \(|v|/\hbar=25.0\,\mathrm{s^{-1}}\). Find the line-centre probability, separation of the first zeros and full half-height width in hertz.

Work through the solution

At resonance first-order probability is

\[(25\times0.004)^2=0.0100.\]

The first zeros are 250 Hz on either side, giving a 500 Hz separation. The full half-height width is

\[0.886/0.004=221.5\,\mathrm{Hz}.\]

A Lorentzian fit with its width interpreted as a spontaneous lifetime would mistake pulse broadening for decay. Doubling \(T\) while keeping coupling fixed is a diagnostic: the first-order peak would rise fourfold and the width halve. At large peak probability use the full two-level dynamics rather than extrapolating the quadratic indefinitely.

Verify the breakdown against exact two-level dynamics

Assume an isolated resonantly driven two-state system with rotating-frame Hamiltonian off-diagonal \(v\) and zero detuning. What replaces the first-order expression when \(T=\pi\hbar/(2|v|)\)? At which small pulse area is the fractional error approximately one percent?

Work through the solution

The resonant Hamiltonian squares to \(|v|^2I\), so the exact probability is \(\sin^2(|v|T/\hbar)\). At the stated pulse time it is unity while the first-order result is \((\pi/2)^2=2.47\), impossible as a probability. For pulse area \(a=|v|T/\hbar\),

\[\sin^2a=a^2-a^4/3+\cdots.\]

The relative discrepancy is approximately \(a^2/3\), reaching 1% at \(a\simeq0.173\). The pulse can already make a measurable few-percent transition while first-order theory remains reasonably accurate. A dense continuum requires checking the total across all levels as well.

Infer an accessible density from the observed time dependence

At long-enough but weak-depletion times an ensemble loses 2.0% population in 5.0 ns. The squared box matrix element is calibrated as \(2.5\times10^{-17}\,\mathrm{eV^2}\). Infer \(\rho\), estimate the recurrence scale and test whether this interpretation is internally consistent.

Work through the solution

The slope estimate is \(4.0\times10^6\ \mathrm{s^{-1}}\). With \(\hbar=6.5821\times10^{-16}\,\mathrm{eV\,s}\) the inferred \(\rho=\Gamma\hbar/(2\pi|v|^2)=1.68\times10^7\,\mathrm{eV^{-1}}\). The corresponding spacing is \(5.97\times10^{-8}\) eV and recurrence scale \(h/\delta E\simeq69\) ns. A 5 ns observation fits within that scale, with about 14 spacings to the first zero. Two percent is compatible with weak depletion. Smoothness of the density and a single accessible channel still require independent spectral checks. Repeating the measurement at several durations reveals whether the inferred slope is stable.

Further reading

Measure tunnelling from a four-site spectrum

Four localised orbitals form a minimal double well. Raise the inner two site energies and ask why two states concentrated in the outer wells still acquire different energies. Measure the splitting in the spectrum, predict an oscillation in time and reproduce the levels independently with OneSimulation.

Construct an operator before drawing an energy diagram

Label the sites \(1,2,3,4\) in order. The end orbitals have on-site energy zero, the middle two have energy \(V>0\) and every neighbouring pair has real hopping matrix element \(-t\) with \(t>0\). The four occupation states form an orthonormal basis for one particle. Equal diagonal energies of the ends do not make their symmetric and antisymmetric combinations degenerate when there is a virtual path through the interior. There are no direct links between sites one and three or one and four. Keeping track of every allowed step will fix the power of \(t\) in the final answer.

\[H=\begin{pmatrix}0&-t&0&0\\-t&V&-t&0\\0&-t&V&-t\\0&0&-t&0\end{pmatrix}.\]

Reflection maps \(1\leftrightarrow4\) and \(2\leftrightarrow3\), and commutes with \(H\). In each parity sector use the normalised outer and inner basis vectors \((|1\rangle\pm|4\rangle)/\sqrt2\) and \((|2\rangle\pm|3\rangle)/\sqrt2\). The diagonal outer element vanishes in both sectors; the hopping inside the middle pair shifts its even and odd energies to \(D_e=V-t\) and \(D_o=V+t\). The outer–inner matrix element remains \(-t\). This reduces the four-dimensional problem to two symmetric two-by-two matrices without neglecting any state.

Eliminate the barrier amplitudes and estimate the splitting

In a sector with interior energy \(D\), the secular equation is

\[E(E-D)=t^2.\]

The lower root is \(E_-(D)=[D-\sqrt{D^2+4t^2}]/2\), or the numerically better \(-2t^2/(D+\sqrt{D^2+4t^2})\). For \(D\gg t\) the shift is approximately \(-t^2/D\). It is more negative for the even state because \(D_e<D_o\). Subtract the two shifts before approximating their difference.

\[\Delta E=E_-(D_o)-E_-(D_e)\simeq t^2\left(\frac{1}{V-t}-\frac{1}{V+t}\right)\simeq\frac{2t^3}{V^2}.\]

A single outward excursion produces an order-\(t^2/V\) shift in both end states. Only a three-hop path connects the different ends, so their splitting is smaller. Measuring an overall displacement of two spectral lines and measuring the distance between them test different physical mechanisms.

Predict a time trace and define what is measured

Denote the two low-energy eigenstates by \(|e\rangle,|o\rangle\). Prepare \((|e\rangle+|o\rangle)/\sqrt2\). In the corresponding opposite superposition \((|e\rangle-|o\rangle)/\sqrt2\), the occupation at time \(\tau\) equals \(\sin^2(\Delta E\,\tau/2\hbar)\). Its first maximum is at \(\pi\hbar/\Delta E\). These superpositions include interior weight, especially at low barrier. A detector on site four alone measures a different projector. Preparing bare site one excites both high and low doublets and can generate additional fast oscillations.

For \(V/t=4\), the two lower eigenvalues in units of \(t\) are \((3-\sqrt{13})/2\) and \((5-\sqrt{29})/2\), about −0.30278 and −0.19258. Their separation is about \(0.11019t\). The high-barrier approximation gives \(0.125t\). With \(t=1\,\mathrm{meV}\), \(\hbar=0.65821\,\mathrm{meV\,ps}\) and the first complete transfer in the dressed basis takes about 18.8 ps. If a measurement integrates over many such oscillations, it may return one half despite perfectly coherent evolution.

Compare spectra from three independent constructions

Use the parameter controls to vary the middle barrier and hopping. The plot shows the exact splitting and its leading virtual-hopping prediction over a range of \(V/t\). The printed result gives an actual transfer time. The downloadable OneSimulation model builds the original four-site Hamiltonian and solves its eigenvalue problem by contour integration. Compare all four eigenvalues with the two parity blocks before interpreting their small difference. A wrong sign on one edge of this open chain can be removed by a local change of basis and may leave its spectrum unchanged, so also check any phase-sensitive observable used for preparation.

Keep the hopping fixed at 1 meV and compare two barriers. Start with a 4 meV barrier and raise it to 8 meV. Record both splittings and estimate the change in the first transfer time before reading off the prediction.

Tutorial

Hold \(V\) fixed and halve \(t\) in the high-barrier limit. How do the common shift, splitting and transfer time change?

Work through the solution

The leading common shift scales as \(t^2/V\) and falls by four. The splitting scales as \(t^3/V^2\) and falls by eight. The transfer time grows eightfold. Halving both \(V\) and \(t\) instead keeps their ratio fixed and halves every eigenvalue.

Explain why a small static asymmetry between the end wells can suppress almost complete transfer while increasing their measured frequency splitting.

Work through the solution

In a two-state reduction, detuning \(\delta\) and coupling \(J\) give separation \(\sqrt{\delta^2+4J^2}\). Starting in one localised state, the maximum transfer probability is \(4J^2/(\delta^2+4J^2)\). Both the frequency and the contrast are needed to infer the coupling.

How could one check that a contour solver has found both members of a closely spaced doublet rather than printing one twice?

Work through the solution

Check the rank of the independent projected vectors and the residual norm for each vector. Then exploit reflection parity or solve in each symmetry sector independently. Repeating a low residual for two nearly parallel vectors does not establish a two-dimensional eigenspace.

The continuous barrier calculation provides a different model in which barrier width eventually produces an exponential dependence.

Irreversible heat transfer and fluctuating signals

Measure a transport coefficient using a steady gradient and a decay. Derive the fluctuation that survives in equilibrium and work out which part of it a finite-bandwidth instrument measures.

  1. Steady conduction, thermal resistance and insulation
  2. Thermal diffusion and transient surface cooling
  3. Heat-exchanger effectiveness and finite capacity rates
  4. When another centimetre of cooling fin stops helping
  5. A moving boundary in a freezing layer
  6. Diffusion with a stationary carrier gas
  7. Measure how quickly a dielectric follows an electric field
  8. Measure equilibrium field fluctuations with a capacitor
  9. Measuring magnetic core loss by a hysteresis loop and by calorimetry
  10. Optical trapping and Brownian calibration of a dielectric bead
  11. How an unobserved environment changes a quantum state
  12. Recover a transition frequency from two separated pulses

Steady conduction, thermal resistance and insulation

Derive the heat leak through a cylindrical wall and identify when increasing insulation thickness can increase heat transfer.

From first principles

Derive series thermal resistance from conservation of heat rate

Consider conduction along a prescribed path through a stationary material, with local area \(A(x)\) normal to the heat flow and conductivity \(k(x)>0\). Assume a one-dimensional steady state, no side losses and no heat generation. A balance on an elementary slice gives a single heat rate \(\dot Q\) at every position. Fourier's measured constitutive relation links that heat rate to the temperature gradient:

\[\frac{d\dot Q}{dx}=0,\]
\[\dot Q=-k(x)A(x)\frac{dT}{dx}.\]

Separate variables and integrate from the hot to the cold surface. An exterior fluid film described by \(\dot Q=h A_s(T_s-T_\infty)\) introduces an additional drop proportional to the same heat rate:

\[T_{\rm hot}-T_\infty=\dot Q\left[\int_{\rm solid}\frac{dx}{k(x)A(x)}+\frac{1}{h A_s}\right].\]

The bracket is a thermal resistance in K/W. For a plane homogeneous layer it gives \(L/(kA)\); for radial conduction in a cylinder the local area \(2\pi rL\) varies, giving a logarithm. Adding resistances is justified by a common heat rate. Heat-generating layers or side branches require a separate balance before using a series formula.

Derivation and applications

How the changing area sets resistance in a spherical shell

Heat passing through the insulation of a spherical vessel spreads over a larger surface as it travels outward. Treat an inner surface at radius \(r_i\) as isothermal, a concentric outer radius \(r_o\), constant thermal conductivity \(k\), and uniform outside convection coefficient \(h\). Assume steady radial conduction with no internal heat generation, perfect interfaces and a uniform ambient temperature \(T_\infty\). With no accumulation between concentric spheres, the heat rate is constant even though local heat flux decreases outward.

Fourier’s empirical law specifies flux from temperature gradient. Multiply it by the local area and rearrange so that each radial slice contributes its own temperature drop:

\[\dot Q=-4\pi r^2 k\,dT/dr,\]
\[T_i-T_o=\frac{\dot Q}{4\pi k}\int_{r_i}^{r_o}\frac{dr}{r^2}.\]

The outer convective drop equals the same heat rate divided by the outer film conductance. Adding both drops gives a series relation:

\[\frac{T_i-T_\infty}{\dot Q}=R=\frac{1}{4\pi k}\!\left(\frac1{r_i}-\frac1{r_o}\right)+\frac1{4\pi h r_o^2}.\]

Increasing \(r_o\) adds conduction resistance but also raises film area. The sign of the derivative decides which effect dominates:

\[\frac{dR}{dr_o}=\frac{1}{4\pi k r_o^2}-\frac{2}{4\pi h r_o^3},\]
\[r_{\rm critical}=2k/h .\]

For an initially smaller radius, adding a thin layer can reduce total resistance; after this minimum the resistance grows. The result presumes fixed \(h\) and surface temperature \(T_i\). If changes in geometry substantially change natural convection or radiation, the assumed film law must be revisited.

Worked example

Evaluate an insulated sensor bead

Take \(r_i=3.00\) mm, \(r_o=6.00\) mm, \(k=0.0400\) W/(m K) and \(h=10.0\) W/(m² K). The shell contributes \(331.6\) K/W and the film \(221.0\) K/W. A \(40.0\) K inner-to-ambient difference gives \(0.0724\) W. The uncoated bead had outer resistance \(884\) K/W and lost only \(0.0452\) W. At \(6\) mm the coating is still below the \(8.00\) mm critical radius.

Second application

Determine whether a change in airflow reverses the trend

With forced airflow raising \(h\) to \(40.0\) W/(m² K), the critical radius falls to \(2.00\) mm, inside the bare bead. The bare and coated resistances become \(221\) and \(331.6+55.3=386.9\) K/W. The coating now reduces heat loss from \(0.181\) to \(0.103\) W. The same layer can change the sign of its effect because the surrounding film is part of the experiment.

Try it · Spherical insulation

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Turn heat flux into a temperature field

Energy moves through a stationary homogeneous solid down its temperature gradient. For isotropic conduction Fourier’s law is

\[\mathbf q=-k\nabla T,\]

where \(\mathbf q\) is heat flux in W/m² and \(k\) is thermal conductivity. A steady one-dimensional wall with no internal heat generation passes the same heat rate at every cut. Heat flux is uniform only when the area of the cuts is uniform. That distinction matters for pipes and spherical shells.

Let an inner cylindrical surface at radius \(r_i\) be warmer than the outer one at \(r_o\). Assume a long concentric wall of length \(L\), constant \(k\), negligible end loss and axisymmetry. Fourier’s law gives

\[\dot Q=-2\pi rLk\,dT/dr,\]

with outward rate taken positive. The area grows with radius, so the magnitude of \(dT/dr\) decreases outward even though the heat rate is unchanged.

Derive and combine thermal resistances

Separate and integrate over the cylindrical wall. This yields

\[T_i-T_o=\dot Q\ln(r_o/r_i)/(2\pi k L).\]

The cylindrical conduction resistance is the factor multiplying \(\dot Q\). At an outer convection boundary \(\dot Q=h\,2\pi r_oL(T_o-T_\infty)\), giving another resistance between the surface and the bulk surroundings. For a prescribed inner surface temperature,

\[\dot Q=\frac{T_i-T_\infty}{\ln(r_o/r_i)/(2\pi kL)+1/(2\pi r_oLh)}.\]

For multiple concentric layers, add the conduction resistance of each. The drops across series resistances sum because the same rate passes through them all. Poor contact between layers can add another temperature jump. A parallel heat leak bypassing the insulation carries part of the total heat under a common temperature difference, so its conductance adds instead.

Estimate the heat leak from a warm pipe

Take \(L=1.0\) m, \(r_i=0.020\) m and \(r_o=0.040\) m. The insulation has \(k=0.050\) W/(m K) and the surroundings have \(h=10\) W/(m² K), \(T_\infty=293\) K. The inner insulation surface is held at 353 K. The conduction resistance is \(\ln2/[2\pi(0.050)(1)]=2.206\) K/W, and the outer film resistance is

\[1/[10(2\pi)(0.040)(1)]=0.398\,\mathrm{K/W}.\]

Total heat loss is \(60/(2.206+0.398)=23.0\) W per metre of pipe.

The outer surface is

\[293+(23.0)(0.398)=302.2\,\mathrm{K}.\]

The rest of the 60 K difference is within the insulation. The heat flux at the outer surface is half that at the inner surface, because the heat-transfer area is twice as large. Assigning the outer circumference to the entire wall in a flat-wall formula would miss this variation. When thickness is very small relative to radius, expanding the logarithm recovers the plane-wall approximation.

Explain the critical radius

Increasing \(r_o\) makes the conduction resistance grow but makes the convection resistance shrink. At fixed \(T_i,T_\infty,h,k\), differentiating the total resistance gives

\[dR/dr_o=1/(2\pi Lk r_o)-1/(2\pi Lh r_o^2).\]

Its minimum occurs at \(r_c=k/h\); that radius maximises heat loss. Here \(r_c=0.0050\) m, already below the bare pipe radius, so adding this insulation reduces loss from the outset. A much thinner wire could initially lose more heat because its exposed area increases faster than the wall resistance. This conclusion assumes the same external coefficient as the diameter changes. If natural convection or radiation changes appreciably, the boundary model and its temperature dependence must be reconsidered.

Recover an unknown contact resistance

A 0.010 m² test sandwich passes 8 W at steady state between measured outer face temperatures of 50 and 40 °C. Its measured total resistance is

\[10/8=1.25\,\mathrm{K/W}.\]

The two known solid layers together account for 0.75 K/W, leaving 0.50 K/W attributable to the interface if other parasitic paths are small. The area-normalised contact resistance is \(R''=A R=0.0050\,\mathrm{m^2K/W}\), corresponding to conductance \(1/R''=200\,\mathrm{W/(m^2K)}\). A pair of thermocouples on opposite sides of the interface should then show a 4 K temperature difference. That independent measurement helps distinguish contact resistance from an unaccounted external heat loss.

Derive the temperature field along a cooling fin

A fin adds area for convection but must first conduct heat from its base to that area. Treat a straight fin with constant cross-sectional area \(A_c\), exposed perimeter \(P\), conductivity \(k\) and uniform film coefficient \(h\). Its base is held at \(T_b\) and surrounding air at \(T_\infty\). Assume the temperature is nearly uniform across each fin section; a small transverse Biot number supports this approximation. Take the tip as adiabatic, appropriate when tip area is small or insulated. Define excess temperature \(\theta=T-T_\infty\).

A slice \(dx\) loses heat \(hP\theta\,dx\) to convection. Its decrease in axial heat rate must supply that loss. Fourier’s law \(Q_x=-kA_c\,d\theta/dx\) then yields \(\theta''-m^2\theta=0\), where \(m=\sqrt{hP/(kA_c)}\). The boundary conditions are

\[\theta(0)=\theta_b,\ \theta'(L)=0.\]

Using a hyperbolic cosine referenced to the insulated end gives

\[\theta(x)=\theta_b\frac{\cosh[m(L-x)]}{\cosh(mL)},\]
\[Q_b=\sqrt{hPkA_c}\,\theta_b\tanh(mL).\]

If the whole fin stayed at base temperature, heat removal would be \(hPL\theta_b\). The ratio \(\eta_f=\tanh(mL)/(mL)\) is the fin efficiency under the stated tip model. A very long fin can have low efficiency although it removes more heat than a short one; efficiency measures use of installed area, while total heat removal measures cooling duty.

Decide whether doubling fin length is worthwhile

An aluminium fin has rectangular section 20 mm by 2 mm, length 50 mm and conductivity 180 W/(m K). Air at 25 °C flows over it with \(h=35\,\mathrm{W/(m^2K)}\), and the base is at 75 °C. Thus

\[A_c=4.0\times10^{-5}\,\mathrm{m^2},\ P=0.044\,\mathrm m,\ \theta_b=50\,\mathrm K.\]

The transverse length \(A_c/P=0.909\,\mathrm{mm}\) gives \(hA_c/(kP)=0.000177\), consistent with small cross-sectional gradients. The fin parameter is \(m=\sqrt{35(0.044)/[180(4\times10^{-5})]}=14.6\,\mathrm{m^{-1}}\); hence \(mL=0.731\) and \(\tanh(mL)=0.624\).

The base heat rate is

\[\sqrt{35(0.044)(180)(4\times10^{-5})}(50)(0.624)=3.29\,\mathrm W.\]

Fin efficiency is

\[0.624/0.731=0.854.\]

Doubling length makes \(mL=1.46\) and raises heat removal to about \(5.27\tanh(1.46)=4.73\,\mathrm W\). Twice the material therefore gives only 44% more cooling. The original covered base area by itself would convect \(35(4\times10^{-5})(50)=0.070\,\mathrm W\), so the fin still offers a large improvement. Adding several fins can change the film coefficient through crowding, and finite contact resistance can lower the effective base temperature. Those effects must be checked before multiplying a single-fin heat rate by the number installed.

A surface thermometer offers a second way to test the heat-transfer model. The insulated-tip solution gives

\[T(L)=25+50/\cosh(0.731)=64.1^\circ\mathrm C.\]

If a thin thermocouple instead measures nearly 75 °C all along a fin while the base still sheds only the predicted few watts, the effective film coefficient may be smaller than assumed. A much colder measured tip could indicate strong local tip convection or poor base contact. Interpret a profile together with the base heat rate: several combinations of conductance, base temperature and film conditions can reproduce one measured temperature, but they need not reproduce both the profile and the total cooling duty.

The root of the fin offers a particularly direct simultaneous measurement of axial temperature gradient and supplied heat rate.

Infer wall cooling from a measured skin-friction force

The film coefficient in a thermal-resistance calculation carries information about transport within the flow. For a smooth isothermal plate, take a steady parallel free stream of speed \(U\) and temperature \(T_e\). Define \(\theta=(T-T_w)/(T_e-T_w)\). Both \(u/U\) and \(\theta\) rise from zero at the wall to one in the outer stream. If momentum and heat diffuse at equal rates, their transport equations and boundary conditions match for a constant-property, zero-pressure-gradient boundary layer starting at the same leading edge. Under this approximation their profiles and their normalized wall gradients coincide. In turbulent flow the analogy additionally relies on similar turbulent diffusivities.

For a wall hotter than the stream the heat flux into the fluid and the magnitude of skin friction are \(q''=k(T_w-T_e)\partial_y\theta|_w\) and \(\tau_w=\mu U\partial_y(u/U)|_w\). Divide the equations. At \(Pr=\mu c_p/k=1\), the unknown gradient cancels. With \(q''=h(T_w-T_e)\) the Reynolds analogy becomes

\[h\simeq\frac{c_p\tau_w}{U},\]
\[St=\frac{h}{\rho Uc_p}\simeq \frac{C_f}{2},\]
\[C_f=\frac{\tau_w}{\tfrac12\rho U^2}.\]

A small heat-transfer tunnel has effective \(Pr\) close to one. At \(U=10.0\,\mathrm{m\,s^{-1}}\), the stream has \(\rho=1.20\,\mathrm{kg\,m^{-3}}\) and \(c_p=1000\,\mathrm{J\,kg^{-1}K^{-1}}\). A force balance isolates the skin friction on one flush plate face of area \(0.50\,\mathrm{m^2}\), and measures \(0.180\,\mathrm N\). The mean shear is \(0.360\,\mathrm{Pa}\), hence \(\bar C_f=0.00600\) and \(\bar h\simeq36.0\,\mathrm{W\,m^{-2}K^{-1}}\). A uniform wall 20 K above the stream loses approximately \(36(0.50)(20)=360\,\mathrm W\) by convection. Average drag produces an average coefficient because both quantities are integrated over the same face. Pressure drag from a protruding instrument, an unheated entry length or a fluid with a very different Prandtl number would invalidate that identification.

Can adding insulation initially increase heat loss?

A long wire of radius 2 mm is held 50 K above ambient. Insulation of conductivity 0.08 W/(m K) adds radial resistance but increases exterior convection area. Add cylindrical conduction and convection resistances per unit length before converting back to heat rate.

Can adding insulation initially increase heat loss?. Horizontal axis: Outer radius of insulation (mm). Vertical axis: Heat loss per length (W/m). Data follow the figure.
At h = 8 W/(m² K) heat loss peaks at the critical radius k/h = 10 mm; at h = 32 it peaks at 2.5 mm. This effect assumes constant surface film coefficient and prescribed inner temperature. A fixed-power heater poses a different question.
Read values from the plot
Heat loss per length (W/m) at selected values of Outer radius of insulation (mm).
Outer radius of insulation (mm)Outer film h = 8 W/(m² K)Outer film h = 16 W/(m² K)Outer film h = 32 W/(m² K)
25.026510.05320.106
7.7049.496212.58115.022
13.59.48311.02411.998
19.2969.02439.950110.488
258.59039.22069.5717

Download all 251 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Raise the film coefficient until the critical radius falls below the wire radius. Check whether adding insulation can still increase heat loss.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

Thermal diffusion and transient surface cooling

Use diffusion time, Biot number and penetration depth to choose between a uniform-body model and a spatial temperature field.

From first principles

Derive thermal diffusion from stored energy and conductive flux

Let a stationary homogeneous solid have density \(\rho\), specific heat \(c\) and thermal conductivity \(k\). Assume no heat generation and consider one-dimensional temperature variation. A slice of area \(A\) and thickness \(dx\) stores energy at rate \(\rho c A\,dx\,\partial_tT\). The difference between the conductive flux entering and leaving gives

\[\rho c A\,dx\,\partial_tT=A[q''(x)-q''(x+dx)]\quad\Longrightarrow\quad \rho c\,\partial_tT=-\partial_xq'' .\]

Fourier's law \(q''=-k\partial_xT\) closes this balance. For constant properties the diffusion equation and its characteristic time over distance \(L\) follow:

\[\partial_tT=\alpha\,\partial_{xx}T,\]
\[\alpha=\frac{k}{\rho c},\qquad t_{\rm diff}\sim L^2/\alpha .\]

Initial temperatures and boundary heat-flux or temperature conditions are needed to select a specific solution. If conduction inside the solid is sufficiently rapid relative to transfer at its surface, one can integrate the balance using an almost uniform interior temperature. Comparing the internal and external resistance scales yields the Biot number \(hL_c/k\) used for that simplification.

Background · Biot number
\[\mathrm{Bi}=hL_c/k\]

Here h is a surface heat-transfer coefficient and k is conductivity. A small Biot number supports a nearly uniform specimen temperature for the specified boundary condition.

Derivation and applications

Predict how a thermal probe follows a changing fluid temperature

A sensor calibrated by an abrupt temperature step can lag behind a fluid that is itself heating steadily. Take a body of mass \(m\), heat capacity \(c\), exposed area \(A\) and film coefficient \(h\) with negligible internal temperature gradients. This lumped description requires internal conduction to be fast compared with surface heat transfer. Treat properties and \(h\) as constant and neglect self-heating, radiation and lead conduction. Denote the body temperature by \(T\), fluid temperature by \(T_f\), and set \(\tau=mc/(hA)\).

An instantaneous energy balance gives a first-order differential equation. For a linearly increasing fluid temperature \(T_f=T_0+\beta t\), define the lag \(D=T_f-T\):

\[mc\,\dot T=hA(T_f-T),\]
\[\dot D + D/\tau=\beta .\]

Suppose the probe and fluid start in equilibrium at \(T_0\). Multiply the lag equation by \(e^{t/\tau}\) and integrate from zero. The integrating factor converts the left side to a single derivative:

\[e^{t/\tau}D(t)=\beta\int_0^t e^{s/\tau}\,ds=\beta\tau(e^{t/\tau}-1).\]

Subtract the resulting lag from the prescribed fluid history to obtain the reading:

\[T(t)=T_0+\beta[t-\tau(1-e^{-t/\tau})] .\]

For \(t\ll\tau\) the rise begins quadratically, since the initial film temperature difference was zero. For \(t\gg\tau\) the probe warms at the same rate as the fluid but reads low by \(\beta\tau\). Cooling ramps reverse the sign. A measured constant lag is therefore evidence for this model only after the startup transient has decayed.

Worked example

Evaluate the reading during a ramp calibration

A probe has \(mc=0.800\) J/K and \(hA=0.100\) W/K, hence \(\tau=8.00\) s. Start at \(20.0^\circ\)C and heat the fluid by \(0.500\) K/s. At \(t=16.0\) s the fluid is at \(28.0^\circ\)C and the lag is \(4.00(1-e^{-2})=3.46\) K, so the probe reads \(24.5^\circ\)C. Simply subtracting the eventual \(4.00\) K would overcorrect during startup.

Second application

Estimate a time constant without an abrupt temperature step

During a long calibration ramp of \(0.200\) K/s, a second probe remains \(1.20\) K below an independent fluid reference. Its inferred time constant is

\[\tau=1.20/0.200=6.00\,\mathrm{s}.\]

If the fluid is then held fixed, the remaining lag decays exponentially. Waiting \(6.00\ln(1.20/0.100)=14.9\) s brings the error below \(0.100\) K. The hold and the ramp test two different responses using the same fitted parameter.

Try it · Probe ramp

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Allow energy to accumulate in the material

A surface thermocouple responds rapidly to a cold wash, while the interior of a thick part can remain hot. To predict the time needed to cool the centre, steady thermal resistance alone is insufficient. Enclose a differential slice of material. Incoming conductive heat minus outgoing heat plus local generation equals the rate of change of its stored energy. Substituting Fourier’s law in a homogeneous stationary solid gives

\[\rho c_p\frac{\partial T}{\partial t}=k\nabla^2T+\dot q_v,\]
\[\alpha=\frac{k}{\rho c_p}.\]

Thermal diffusivity \(\alpha\) in m²/s compares a material’s ability to spread heat with its ability to store it. A large conductivity does not alone guarantee fast adjustment if volumetric heat capacity is also large. Without heat generation, a length \(L\) gives a characteristic diffusion time \(t_d=L^2/\alpha\). The dimensionless Fourier number \(Fo=\alpha t/L^2\) measures how long diffusion has acted relative to that scale.

Decide whether the interior stays nearly uniform

At a convecting boundary \(-k\partial T/\partial n=h(T_s-T_\infty)\). Comparing the resistance of the interior with a fluid film leads to \(Bi=hL_c/k\), often using \(L_c=V/A_s\) for a lumped model. If this ratio is small, commonly below about 0.1 as a first engineering check, the internal temperature difference is small compared with that across the film. Integrating energy over a uniform body then gives

\[\rho c_p V\,dT/dt=-hA_s(T-T_\infty),\]
\[(T-T_\infty)/(T_0-T_\infty)=e^{-t/\tau},\]

with \(\tau=\rho c_pV/(hA_s)\).

The Biot and Fourier numbers answer different questions. A small Fourier number says a disturbance has penetrated only a short distance compared with \(L\). A small Biot number says the boundary transfers heat slowly enough for internal gradients to remain small. Choose the length for each comparison explicitly, especially for a slab cooled on one side rather than both.

Cooling from a fixed surface temperature reaches farther into the solid as the dimensionless time rises.
Semi-infinite cooling profiles plotted against a fixed reference length L. Increasing time by a factor of ten increases the depth of a given temperature ratio by the square root of ten.

Solve a sudden prescribed-temperature change

Consider initially uniform material occupying \(x>0\) whose surface is suddenly held at \(T_s\), with its far interior still at \(T_i\). Neglect internal generation and use constant properties. The initial and boundary conditions have no geometric length scale. Try the similarity coordinate \(\eta=x/(2\sqrt{\alpha t})\) and set \(\Theta=(T-T_s)/(T_i-T_s)\). Differentiating and substituting into the diffusion equation yields \(\Theta''+2\eta\Theta'=0\), with derivatives in \(\eta\). Integrating once gives

\[\Theta'=C e^{-\eta^2}.\]

The limits \(\Theta(0)=0,\ \Theta(\infty)=1\) give

\[\Theta=\operatorname{erf}(\eta).\]

At \(x=0\) the imposed surface temperature holds exactly. At a fixed depth and very early time \(\eta\) is large, so the temperature tends to its initial value. The distance of any fixed fractional temperature change grows as \(\sqrt{t}\). Quadrupling exposure time doubles that distance, a scaling quite different from a body travelling at a constant speed.

Predict depth and validate the time window

A thick solid initially at 373 K is held at 293 K at its surface. With \(\alpha=1.0\times10^{-5}\) m²/s and \(t=10\) s, \(2\sqrt{\alpha t}=0.020\) m. At depth 10 mm, \(\eta=0.50\) and \(\operatorname{erf}(0.50)=0.5205\), giving \(T=293+80(0.5205)=334.6\) K. At 20 mm, \(\operatorname{erf}(1)=0.8427\) gives 360.4 K. The surface has cooled by 80 K while the deeper sensor has cooled by only 12.6 K.

At 40 s the 20 mm sensor reaches the same fraction previously measured at 10 mm. This prediction assumes the remote boundary has not begun to influence the measurement and that the surface temperature is actually prescribed. A finite slab or a convective wash may require a finite-domain diffusion solution instead. Record surface and interior histories to distinguish uncertain boundary conditions from uncertain diffusivity.

Interpret a penetration depth

If two embedded sensors are at 2 and 6 mm in the same semi-infinite specimen, the deeper sensor reaches the same normalised temperature at nine times the shallow sensor’s time because \(x/\sqrt{\alpha t}\) must match. An observed factor much smaller than nine can indicate a heat leak along a probe or a far boundary that has begun to influence the temperature field.

Resolve a slab with a finite surface film

A prescribed surface temperature and a uniformly cooling lump are two useful limits. A finite slab exchanging heat through a finite film generally satisfies neither. Let \(L\) be half-thickness, \(x=0\) the midplane, and \(T_i\) the initial uniform temperature. Both sides suddenly see fluid at \(T_\infty\) with constant \(h\). Using \(X=x/L,\ Fo=\alpha t/L^2\) and \(\Theta=(T-T_\infty)/(T_i-T_\infty)\), the diffusion equation becomes

\[\Theta_{Fo}=\Theta_{XX},\]

with symmetry \(\Theta_X(0)=0\) and film condition \(-\Theta_X(1)=Bi\,\Theta(1)\), where \(Bi=hL/k\).

Seek a separated mode \(\Theta=\cos(\lambda X)e^{-\lambda^2Fo}\). Its derivative vanishes at the midplane. Imposing the convective surface condition gives

\[\lambda\tan\lambda=Bi.\]

The uniform initial condition fixes modal amplitudes by cosine orthogonality on \(0<X<1\):

\[\Theta=\sum_n A_n\cos(\lambda_n X)e^{-\lambda_n^2Fo},\]
\[A_n=\frac{4\sin\lambda_n}{2\lambda_n+\sin(2\lambda_n)}.\]

For \(Bi\ll1\), the smallest root has \(\lambda_1^2\simeq Bi\), its shape approaches a constant, and \(A_1\simeq1\). The decay becomes \(e^{-Bi\,Fo}\), exactly the lumped time scale because \(Bi\,Fo=h t/(\rho cL)\). For a large film coefficient the first root tends towards \(\pi/2\), corresponding to a prescribed surface temperature. The same boundary-value model thus recovers both limiting behaviours.

Predict when the core and surface meet different targets

A 40 mm thick flat slab with \(k=2.0\,\mathrm{W/(m\,K)}\) and \(\alpha=1.0\times10^{-6}\,\mathrm{m^2/s}\) is cooled on both sides by \(h=50\,\mathrm{W/(m^2K)}\). It starts at 100 °C in fluid at 20 °C. Here \(L=0.020\) m and \(Bi=0.50\). The first root of \(\lambda\tan\lambda=0.5\) is 0.6533 and \(A_1=1.070\). After 600 s, \(Fo=1.50\). The first term gives centre excess ratio \(1.070\exp[-(0.6533)^2(1.50)]=0.564\), hence \(T_c=65.1^\circ\mathrm C\). At the surface multiply by \(\cos(0.6533)=0.794\), giving about 55.9 °C. Higher roots are strongly attenuated at this Fourier number.

A process requiring the centre to fall below 50 °C needs centre ratio \((50-20)/(100-20)=0.375\). Solve \(Fo=\ln(1.070/0.375)/0.6533^2=2.46\), or approximately 984 s. By contrast a lumped estimate gives \(Fo=-\ln(0.375)/0.5=1.96\), about 785 s. It underestimates the core cooling time by over three minutes because the film and internal gradients both matter. An early-time surface prediction requires more modes than this late-time centre criterion. In particular the first term alone gives a centre ratio above unity at time zero, signalling that the remaining terms are necessary to reconstruct the original uniform state.

If product quality depends on average energy content rather than the hottest spot, average the first-mode shape over half the thickness. Its factor \(\int_0^1\cos(\lambda_1 X)dX=\sin\lambda_1/\lambda_1=0.930\) gives mean excess ratio \(0.564(0.930)=0.525\) after 600 s. The predicted bulk temperature is therefore about 62.0 °C, between centre and surface as expected. A calorimetric measurement made after removing and mixing the material is closer to the mean than to either point thermometer. A decision to stop cooling based on such a reading can therefore satisfy an average enthalpy requirement while leaving the centre several kelvins above a local temperature limit.

The surface flux can be checked against the rate of thermal energy loss. At 600 seconds each face transfers \(50(55.9-20)=1795\,\mathrm{W/m^2}\) to the air. Per square metre of plan area the slab therefore loses approximately 3590 W. The volumetric heat capacity obtained independently from \(k/\alpha\) is \(2.0\times10^6\,\mathrm{J/(m^3K)}\). Multiplying by total 0.040 m thickness gives an areal capacity of 80000 J/(m² K), and a predicted instantaneous mean cooling rate \(3590/80000=0.0449\,\mathrm{K/s}\). Differentiating the one-term mean temperature gives the same decay rate to within rounding.

This independent balance is especially useful if measurements suggest two different film coefficients on opposite sides. An unequal pair of measured fluxes cannot be fitted by a strictly symmetric half-slab model even if it reproduces one centre temperature. The full-thickness conduction problem then requires both surface boundary conditions; simply replacing them by their arithmetic mean may match total heat over one interval while shifting the hottest location away from the midplane.

Interactive calculation · Change the inputs of this example

Change the parameters of this reference plot and compare its limiting cases. The fixed illustration remains beside the derivation; the adjustable calculation exposes the same dependence on geometry, material properties or loading.

Heat-exchanger effectiveness and finite capacity rates

Derive the counterflow effectiveness relation and determine outlet temperatures when neither stream temperature is fixed.

From first principles

Derive exchanger effectiveness from the limiting heat balance

Consider a steady two-stream heat exchanger with no external heat gain, constant specific heats and no phase change. Each stream has a capacity rate \(C=\dot m c_p\), the power required for one kelvin of temperature change. Applying the first law independently to each stream gives a common transferred heat rate

\[\dot Q=C_h(T_{h,i}-T_{h,o})=C_c(T_{c,o}-T_{c,i}).\]

In passive exchange neither exit can cross the opposite stream’s inlet temperature. Therefore the maximum available temperature change on either stream is bounded by the same inlet difference \(T_{h,i}-T_{c,i}\). The smaller capacity rate limits the largest conceivable common duty. Define effectiveness from this physically accessible upper scale:

\[\dot Q_{\max}=C_{\min}(T_{h,i}-T_{c,i}),\]
\[\varepsilon=\dot Q/\dot Q_{\max},\]
\[\mathrm{NTU}=UA/C_{\min}.\]

The bound need not be reached by a finite exchanger or by every flow arrangement. Local conductance \(U\,dA\) and the changing local temperature difference determine the actual effectiveness. Knowing the two capacity rates and \(\varepsilon\) suffices to reconstruct both outlet temperatures using the separate energy balances.

Background · Heat-exchanger effectiveness
\[\epsilon=\dot Q/[C_{\min}(T_{h,i}-T_{c,i})]\]

Heat-capacity rate is mass flow times specific heat for a single-phase stream. The smaller rate limits the maximum possible sensible heat transfer.

Hot and cold temperatures both fall along a coordinate measured from the hot inlet. The two fluids travel in opposite directions and stay twenty kelvin apart.Open full-size diagram
Read exchanger terminal temperatures at the same physical end The hot stream enters at 80 °C and leaves at 50 °C. The cold stream enters at 30 °C on the right and leaves at 60 °C on the left. Equal heat-capacity rates and uniform conductance per length give parallel lines. The local driving difference is 20 K throughout, even though the cold outlet is hotter than the hot outlet.

Derivation and applications

Where the logarithmic mean temperature difference comes from

A local heat-transfer coefficient multiplies the temperature difference at that location. Integrating one exchanger therefore requires the changing driving difference across its whole area. Take a steady counterflow exchanger with no phase change, constant positive capacity rates \(C_h=\dot m_h c_h\), \(C_c=\dot m_c c_c\), constant overall coefficient \(U\) and no external heat loss. Measure area coordinate \(A'\) along the hot flow. Let \(d\dot Q\) be the positive heat transfer from hot to cold over the increment. Both fluid temperatures decrease along this chosen coordinate because the cold stream flows the other way.

\[d\dot Q=U(T_h-T_c)\,dA',\]
\[dT_h=-d\dot Q/C_h,\]
\[dT_c=-d\dot Q/C_c .\]

Thus \(\Delta=T_h-T_c\) changes linearly with cumulative heat transfer. Write its two physical terminal values as \(\Delta_1=T_{h,i}-T_{c,o}\) and \(\Delta_2=T_{h,o}-T_{c,i}\):

\[d\Delta=(1/C_c-1/C_h)d\dot Q,\]
\[\Delta_2-\Delta_1=(1/C_c-1/C_h)\dot Q .\]

To recover total area, integrate \(dA'=d\dot Q/(U\Delta)\) using the preceding linear relation. Eliminating the reciprocal capacity difference leaves

\[\dot Q=UA\,\frac{\Delta_1-\Delta_2}{\ln(\Delta_1/\Delta_2)} .\]

For equal terminal differences the apparent zero divided by zero has limit \(\Delta_1\). When one positive approach tends toward zero at a fixed heat duty, the necessary area diverges. Terminal differences must pair the temperatures at the same physical end, not two inlet temperatures chosen from opposite ends.

Worked example

Size an exchanger from measured terminal temperatures

A hot stream cools from \(90\) to \(55^\circ\)C while the counterflow cold stream warms from \(20\) to \(60^\circ\)C. The terminal differences are \(30\) and \(35\) K, so their logarithmic mean is

\[5/\ln(35/30)=32.4\,\mathrm{K}.\]

For a duty of \(70.0\) kW and \(U=500\) W/(m² K), the required area is \(4.32\) m². The capacities \(2.00\) and \(1.75\) kW/K independently deliver the same \(70.0\) kW.

Second application

Compare equal duty at a tighter terminal approach

A redesign has measured terminal differences of \(5.00\) and \(35.0\) K at the same duty and coefficient. The logarithmic mean drops to \(30/\ln7=15.4\) K and the required area rises to \(9.08\) m². Using the arithmetic mean \(20.0\) K would give only \(7.00\) m². The region with low driving difference consumes disproportionately more area per kilowatt transferred.

Try it · Lmtd area

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Set the maximum possible heat rate

In a two-stream heat exchanger, the hot temperature falls as the cold temperature rises. Treat each stream as single phase with constant heat capacity rate \(C=\dot m c_p\) in watts per kelvin. Neglect heat leakage, axial conduction and changes in kinetic energy. A steady overall balance gives

\[Q=C_h(T_{hi}-T_{ho})=C_c(T_{co}-T_{ci}).\]

Performing this balance alone leaves both outlet temperatures and the transferred heat rate unknown.

The stream with smaller capacity rate would undergo the larger temperature change for a given heat rate. Even in an ideal counterflow exchanger it cannot pass the inlet temperature of the other stream at its nearest end. Thus \(Q_{\max}=C_{\min}(T_{hi}-T_{ci})\). Effectiveness is \(\varepsilon=Q/Q_{\max}\), which immediately gives both outlet temperatures once the heat transfer law fixes \(\varepsilon\).

Apply a balance to an area element

Let \(A\) increase along the hot stream and write the local temperature difference \(\Delta=T_h-T_c\). An element transfers \(dQ=U\Delta\,dA\). In counterflow both temperature profiles decrease when followed in the hot-stream direction, giving \(dT_h=-dQ/C_h\), \(dT_c=-dQ/C_c\). Hence \(d\ln\Delta/dA=U(1/C_c-1/C_h)\). Integrate over area and express each end difference in terms of inlet temperatures and total heat rate using the stream balances.

\[NTU=UA/C_{\min},\]
\[C_r=C_{\min}/C_{\max},\]
\[\varepsilon=\frac{1-\exp[-NTU(1-C_r)]}{1-C_r\exp[-NTU(1-C_r)]}.\]

The sign in the differential balance follows from the chosen spatial direction. In parallel flow the cold stream warms along that coordinate and the local temperature difference decays more rapidly. For equal capacity rates the counterflow formula has a removable zero over zero. Its limit is \(NTU/(1+NTU)\), which can also be obtained from the constant temperature difference in that special case.

OneSimulation · Can the cold outlet leave hotter than the hot outlet?

The hot stream enters at 80 °C with a heat-capacity rate of 2 kW/K. The cold stream enters at 20 °C with a capacity rate of 1 kW/K. Compare the same heat exchanger conductance in parallel flow and counterflow. Obtain the two discharges from the same transferred heat rate \(\dot Q\), using \(\dot C=\dot m c_p\).

\[T_{h,o}=T_{h,i}-\dot Q/\dot C_h,\]
\[T_{c,o}=T_{c,i}+\dot Q/\dot C_c.\]

Equal outlets occur at 60 °C and require 40 kW, or effectiveness \(2/3\). Parallel flow approaches this common temperature asymptotically. Counterflow reaches it at \(\mathrm{NTU}=2\ln2\). At NTU 2 the two OneSimulation models predict cold and hot outlets of 66.5 °C and 56.8 °C in counterflow, against 58.0 °C and 61.0 °C in parallel flow. The counterflow outlets sit at opposite ends; heat still travels locally from the hotter fluid to the colder one.

"""Check for an outlet temperature cross in a two-stream heat exchanger."""
import matplotlib.pyplot as plt
import numpy as np
from onesim.physics.systems.process import counterflow_effectiveness, parallel_flow_effectiveness

hot_in, cold_in = 80., 20.       # °C
hot_rate, cold_rate = 2., 1.     # kW/K
capacity_min = min(hot_rate, cold_rate)
ratio = capacity_min/max(hot_rate, cold_rate)
ntu = np.linspace(0, 4, 201)

fig, ax = plt.subplots(figsize=(7, 4), constrained_layout=True)
for name, model, style in [("Counterflow", counterflow_effectiveness, "-"),
                            ("Parallel flow", parallel_flow_effectiveness, "--")]:
    heat = model(ntu, ratio)*capacity_min*(hot_in-cold_in)  # kW
    hot_out = hot_in - heat/hot_rate
    cold_out = cold_in + heat/cold_rate
    assert np.allclose(hot_rate*(hot_in-hot_out), cold_rate*(cold_out-cold_in))
    ax.plot(ntu, hot_out, style, color="#a5442e", label=f"{name}, hot outlet")
    ax.plot(ntu, cold_out, style, color="#19596a", label=f"{name}, cold outlet")

ax.axvline(2*np.log(2), color="0.5", linestyle=":", label="Counterflow outlets equal")
ax.set(xlabel="Transfer units UA / minimum capacity rate", ylabel="Outlet temperature (°C)")
ax.legend(fontsize=8)
fig.savefig("engineering-thermodynamics.png", dpi=170)
Solid counterflow outlet temperature curves cross; dashed parallel-flow outlet temperatures approach a common limit from either side.
Compare outlets at the same horizontal coordinate. A temperature cross in counterflow describes two different positions along the exchanger.

Download the Python example

Change the inputs of this exact example and compare the recalculated curves with the recorded OneSimulation output above. The browser evaluates the stated analytical or modal reference.

Predict both outlet temperatures

A counterflow cooler receives a hot stream at 90 °C with \(C_h=2.0\,\mathrm{kW/K}\) and a cold stream at 20 °C with \(C_c=1.0\,\mathrm{kW/K}\). Its conductance \(UA\) is 1.50 kW/K. Thus \(C_r=0.5\), \(NTU=1.5\), and the exponential is

\[e^{-0.75}=0.4724.\]

Effectiveness is 0.6908. Consequently \(Q=0.6908(1.0)(90-20)=48.4\,\mathrm{kW}\),

\[T_{ho}=90-48.4/2=65.8^\circ\mathrm C,\]
\[T_{co}=20+48.4=68.4^\circ\mathrm C.\]

The cold outlet is warmer than the hot outlet. They are at opposite physical ends, so this does not imply a local reversal of heat flow. The end differences are \(90-68.4=21.6\) K and \(65.8-20=45.8\) K, both positive. Their logarithmic mean is approximately \((45.8-21.6)/\ln(45.8/21.6)=32.2\,\mathrm K\), independently recovering \(Q=UA\Delta T_{\rm lm}\simeq48.3\,\mathrm{kW}\). This local check catches errors caused by swapping the terminal temperatures of a counterflow exchanger.

Predict the counterflow experiment

A smaller stream capacity rate raises NTU when the exchanger conductance is held fixed, yet it can reduce heat transfer in watts because less thermal capacity passes each second. For inlet temperatures 350 and 290 K and \(C_r=0.60\), use the counterflow expression to predict the effectiveness at NTU 1.5 and 3.0. Then halve both capacity rates, as the model does to obtain the second NTU, and predict the ratio of heat rates. Check both outlet temperatures and the hot-stream heat rate, paying attention to which stream has the smaller capacity. Open the heat-exchanger experiment.

Identify which side controls an exchanger’s conductance

The effectiveness relation uses a single conductance \(UA\), but a designer may need to determine whether the hot film, cold film or fouling dominates it. Write the total thermal resistance in K/W as \(R_{\rm tot}=1/(h_hA_h)+R_w+R_f+1/(h_cA_c)\). Areas must be kept explicit if the two sides use different reference areas. Suppose a test can vary hot-side flow while holding cold-side flow, wall resistance and deposit condition fixed. Let a supported correlation in the tested region imply \(h_h\propto\dot m_h^{\,n}\). With \(m_r=\dot m_h/\dot m_{\rm ref}\), the relation takes the linear form

\[(UA)^{-1}=R_{\rm fixed}+R_{h,\rm ref}\,m_r^{-n}.\]

This is the basis of a Wilson-plot style separation. Each measured \(UA\) can be obtained from balanced heat duty and the correct logarithmic mean temperature difference. The intercept estimates the combined fixed resistance; the slope estimates the hot-film resistance at reference flow. One set of measurements alone does not separate cold film from wall and deposits individually. Temperature-dependent material properties and changes in the opposite stream can spoil the assumed linear relation.

Treating \(UA\) as proportional to flow whenever convection rises would ignore the series resistances left in its path. As \(m_r\) becomes large the hot-film term tends to zero, leaving an asymptote \(1/R_{\rm fixed}\) rather than unbounded conductance. Pumping power typically rises over this same change of flow.

Use a flow sweep to distinguish fouling from film resistance

A clean counterflow rig at reference hot-side mass flow has \(UA=500\,\mathrm{W/K}\), giving total resistance \(0.00200\,\mathrm{K/W}\). At twice the flow it has \(UA=600\,\mathrm{W/K}\), or \(0.001667\,\mathrm{K/W}\). Over this interval use measured exponent \(n=0.80\), so

\[2^{-0.8}=0.5743.\]

Subtracting the two equations gives

\[R_{h,\rm ref}=(0.00200-0.001667)/(1-0.5743)=0.000783\,\mathrm{K/W}.\]

The combined fixed resistance is \(0.001217\,\mathrm{K/W}\). Even an ideal hot film could raise conductance only to about 822 W/K under the unchanged fixed-side assumptions.

A later test at reference flow gives \(UA=400\,\mathrm{W/K}\), so total resistance has grown to 0.00250 K/W. If a second flow sweep confirms the same hot-film slope, the added fixed resistance is 0.00050 K/W. For a heat-transfer area of 2.0 m² on the chosen basis this corresponds to fouling resistance \(R_f''=0.0010\,\mathrm{m^2K/W}\). If instead the slope has changed, assigning the entire difference to deposits is unwarranted; changed flow distribution or fluid properties may contribute. Temperature measurement also matters strongly when the two terminal differences are close to sensor uncertainty. Compare the hot and cold enthalpy duties before fitting the conductance and retain the residual across all measured flow settings.

A third clean test can challenge the fitted exponent. At four times reference hot flow, the predicted resistance is \(0.001217+0.000783(4^{-0.8})=0.001475\,\mathrm{K/W}\), or \(UA\simeq678\,\mathrm{W/K}\). A systematic departure that grows at high flow could reflect changing cold-side properties, thermocouple bias or failure of the hot-film correlation. Two calibration points always fit a two-parameter straight line; the independent third point actually tests the assumed dependence.

Determine whether a specified exchanger effectiveness is attainable

Fix both inlet temperatures and \(C_{\min}\). Changing area changes NTU. For constant properties and no losses the effectiveness divides actual heat rate by \(C_{\min}(T_{h,i}-T_{c,i})\). Compare two flow arrangements and the isothermal-stream limit.

Determine whether a specified exchanger effectiveness is attainable. Horizontal axis: Number of transfer units, UA/Cmin. Vertical axis: Heat-exchanger effectiveness. Data follow the figure.
With capacity ratio 0.6, parallel flow approaches only 1/1.6 = 0.625 however large the area. Counterflow can exceed 0.8. An area calculation that ignores the arrangement can return a target that the selected exchanger cannot reach.
Read values from the plot
Heat-exchanger effectiveness at selected values of Number of transfer units, UA/Cmin.
Number of transfer units, UA/CminCounterflow, Cr = 0.6Parallel flow, Cr = 0.6Phase-changing stream, Cr = 0
0000
1.240.616170.539050.71062
2.50.811170.613550.91792
3.760.897430.623480.97672
50.941080.624790.99326

Download all 251 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Move the capacity-rate ratio toward one and compare the finite-area behaviour with the phase-change limit.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

When another centimetre of cooling fin stops helping

A fin adds surface area, but heat must travel down its length before it can reach that area. Derive the temperature profile from an energy balance and quantify how much of the nominal area contributes to cooling.

Balance a short slice with distributed convection

Consider a straight prismatic fin of conductivity k, cross-section A, exposed perimeter P and length L. Hold the root at \(T_b\), let a fluid at \(T_\infty\) surround the fin and use a uniform convection coefficient h. Temperature is assumed nearly uniform across each cross-section. A small transverse Biot number \(h(A/P)/k\) supports that assumption. Ignore radiation and heat loss from the tip. Define \(\theta=T-T_\infty\). The axial heat entering a slice, less the heat leaving its far face, must equal \(hP\theta\,dx\).

\[q_x=-kA\,\theta',\]
\[-{dq_x\over dx}=hP\theta,\]
\[\theta''-m^2\theta=0,\]
\[m=\sqrt{hP/(kA)}.\]

A positive temperature excess makes the heat flow diminish downstream. For an insulated tip \(q_x(L)=0\), so a hyperbolic cosine centered at the tip satisfies the zero-slope condition. Its coefficient follows from the root temperature.

\[{\theta(x)\over\theta_b}={\cosh[m(L-x)]\over\cosh(mL)},\]
\[Q_b=kAm\theta_b\tanh(mL).\]

Efficiency follows by comparing with an isothermal fin

If every part of the lateral area stayed at \(T_b\), the heat transfer would be \(hPL\theta_b\). The actual-to-ideal ratio is therefore

\[\eta_f=\tanh(mL)/(mL).\]

For small mL the temperature falls little along the wall and doubling the area nearly doubles the heat flow. For large mL the root heat flow approaches \(kAm\theta_b\). Near the long-fin limit increasing conductivity or the root cross-section can buy more cooling than adding length. Efficiency alone does not measure total heat removal because it contains the nominal area in its denominator.

Two fins made from the same stock

Use a rectangular aluminium strip, 20 mm wide, 2 mm thick, \(k=200\) W/(m K), \(h=25\) W/(m² K) and \(\theta_b=50\) K. All four long faces are exposed. With \(A=4.0\times10^{-5}\) m² and \(P=0.044\) m, \(m=11.73\) m⁻¹. At 50 mm length, \(mL=0.586\), \(Q_b=2.47\) W and \(\eta_f=0.899\). The tip remains about 42.5 K above ambient.

At 150 mm, the heat rate is 4.43 W and the efficiency drops to 0.536. The material and exposed area tripled, while the heat transfer increased by about 79%. A fin root bonded through a finite contact resistance \(R_c\) would run cooler than the heated base. Replacing the temperature excess by \(T_{\rm base}-T_\infty-Q_b R_c\) in the root heat equation gives a direct way to include the bond in a thermal circuit.

Choose a short fin and inspect how far the infinite-fin approximation is from the insulated-tip temperature. Increase length until the root heat rate is almost saturated. Estimate the added cooling from another centimetre at that point.

Tutorial · select a length from a marginal-benefit criterion

For the same strip, require 95% of the infinitely long fin's heat rate. Find the required length. Then estimate the heat rate if the base is held 50 K above ambient through a contact resistance of 1 K/W.

Show the inverse calculation

Set \(\tanh(mL)=0.95\), giving \(mL=\tfrac12\ln(1.95/0.05)=1.832\) and \(L=0.156\) m. The root conductance there is \(G=kAm(0.95)=0.0891\) W/K. Adding the contact resistance gives

\[Q=50/(1/G+1)=4.09\,\mathrm{W}.\]

The temperature drop across the contact is about 4.09 K. This check distinguishes the fin-root temperature from the base temperature reported by a sensor under the bond.

Further reading · Lienhard and Lienhard · A Heat Transfer Textbook, chapter 4 on conduction and fins

A moving boundary in a freezing layer

A flat cold surface grows a layer of ice from water initially at its melting temperature. Estimate when it will reach a specified thickness, then discover how a finite heat-transfer resistance changes its early growth.

Write a balance at a boundary whose position is unknown

Let the solid occupy \(0<x<s(t)\). The boundary at x=0 is held at \(T_w<T_m\), the liquid remains at \(T_m\), and the solid-liquid interface is at its equilibrium melting temperature. Treat density, latent heat of fusion \(L_f\) and solid conductivity k as constants. Ignore volume change and fluid convection. When the front moves by ds, each unit area releases latent energy \(\rho L_f\,ds\). In this one-phase problem conduction into the cold side removes that energy. Taking the magnitude of heat extracted, the interface condition reads

\[\rho L_f\,{ds\over dt}=k\,{\partial T\over\partial x}\bigg|_{s^-}.\]

The derivative is positive because temperature increases towards the liquid. Solving the full problem requires time-dependent conduction in a domain with a moving outer end. A useful approximation emerges when the sensible heat needed to cool the new solid is small beside its latent heat. Measure that ratio with the Stefan number \({\rm Ste}=c_p(T_m-T_w)/L_f\).

Derive the square-root law and check the approximation

For small Ste the temperature profile in the solid adjusts quickly compared with front growth. Approximate the gradient by \((T_m-T_w)/s\). Multiplying the interface balance by s separates the variables. Integrating from an initial layer \(s_0\) gives

\[s\,ds={k(T_m-T_w)\over\rho L_f}\,dt,\]
\[s^2=s_0^2+{2k(T_m-T_w)\over\rho L_f}t .\]

With zero initial thickness the predicted speed starts unbounded because the model inserts a finite temperature difference across zero resistance. A finite surface heat-transfer coefficient removes this singularity. If coolant at \(T_c\) reaches the wall through a film \(1/h\), the heat flux is \((T_m-T_c)/(1/h+s/k)\). For a layer growing from zero, integration gives

\[t={\rho L_f\over T_m-T_c}\left({s\over h}+{s^2\over2k}\right).\]

The linear term dominates while the film presents the larger resistance. Once the solid is thick, the quadratic term recovers diffusion-controlled growth. These two regimes can be distinguished by recording thickness at equal time intervals.

An ideal wall and a finite film

For water freezing at 0 °C take \(k=2.2\) W/(m K), \(\rho=917\) kg/m³, \(L_f=334\) kJ/kg and \(c_p=2.1\) kJ/(kg K). With a wall at −5 °C the Stefan number is 0.0314. The ideal-wall time to form 10 mm is \(917(334000)(0.01)^2/[2(2.2)(5)]=1392\) s, about 23 minutes. Reaching 20 mm requires four times that duration. The increasing conduction distance accounts for the slowing front.

With coolant at −5 °C and \(h=200\) W/(m² K), the added time for 10 mm is 3063 s. The resulting total is about 74.2 minutes. At that point the film resistance is 0.005 m² K/W and the ice contributes 0.00455 m² K/W. Both terms are of the same order. Vary h and find when a second thickness measurement would provide more information about ice conductivity than a first one.

At a fixed coolant temperature compare the early and late parts of the thickness histories. Increase the film coefficient strongly. Predict where the finite-film curve should approach the fixed-wall result first in relative terms, then read the completion time.

Tutorial · recover the coolant coefficient from one observation

A 15 mm layer is observed after 8000 s with the same properties and coolant temperature. Estimate h from the integrated equation. Would a time below the ideal-wall value be compatible with a positive h in this model?

Show the resistance fit

The ideal-wall contribution is about 3132 s. The remaining 4868 s equals \(\rho L_f s/[h(T_m-T_c)]\), giving \(h\simeq189\) W/(m² K). Both resistances are positive. A shorter time than the ideal-wall prediction would require checking the temperature, initial ice thickness, geometry or material data before assigning a heat-transfer coefficient.

Further reading · RWTH Aachen · Computational Modeling of Multiphysics, chapter 12 on the Stefan problem

Diffusion with a stationary carrier gas

A solvent evaporates into a gas layer. Its molecules diffuse relative to the mixture, while evaporation also induces a bulk molar flow. Work through the species balances to see why the flux ceases to scale linearly with surface concentration.

Choose the reference frame for a flux

Let A be the evaporating species and B an insoluble carrier. A planar film of thickness L lies between the evaporating surface, at mole fraction \(y_s\), and a well-mixed reservoir at \(y_\infty<y_s\). Keep total pressure, temperature, total molar concentration \(c=p/(RT)\) and binary diffusivity D uniform. In a stationary laboratory frame the total species flux equals diffusion relative to the molar-average velocity plus transport by that velocity. If positive z points towards the reservoir, write

\[N_A=-cD{dy_A\over dz}+y_A(N_A+N_B).\]

Steady conditions in one dimension make \(N_A,N_B\) independent of z. Carrier B cannot enter the liquid and has zero net flux there. This fixes \(N_B=0\) throughout the film. B still diffuses towards the interface relative to the moving mixture. Its diffusive flux balances its outward convective flux. The constraint \(N_A+N_B=0\) would instead describe equimolar counterdiffusion between two exchanging species.

Separate variables and enforce both boundary concentrations

Collect the terms in \(N_A\), divide by \(1-y_A\) and integrate from the surface to the reservoir. The remaining integral is a logarithm of the carrier mole fraction.

\[N_A(1-y_A)=-cD{dy_A\over dz},\]
\[N_A={cD\over L}\ln{1-y_\infty\over 1-y_s}.\]
\[1-y_A(z)=(1-y_s)\left({1-y_\infty\over1-y_s}\right)^{z/L}.\]

The concentration profile curves because a given net flux requires a different concentration gradient at different carrier fractions. A dilute expansion of the logarithm gives

\[N_A\simeq(cD/L)(y_s-y_\infty).\]

The exact-to-dilute flux ratio exceeds unity when the surface emits A. The discrepancy becomes measurable long before the carrier disappears. At fractions very close to unity, the assumptions of a stagnant, isothermal film also deserve new scrutiny.

Small and large amounts of vapour at the surface

At 300 K and 1 bar, \(c=40.09\) mol/m³. Take \(D=2.0\times10^{-5}\) m²/s and \(L=5\) mm. The coefficient \(cD/L=0.1604\) mol/(m² s). With a vapour-free reservoir and \(y_s=0.05\), the logarithm is 0.05129 and the predicted flux is 0.00823 mol/(m² s). A linear gradient would give 0.00802, about 2.5% lower.

For \(y_s=0.50\), the flux rises to 0.111 mol/(m² s), versus 0.0802 for the dilute estimate. At mid-depth the exact fraction is \(1-\sqrt{0.5}=0.293\), while linear interpolation gives 0.25. An experimental check can therefore use either a mass-loss measurement or a local concentration measurement. Evaporative cooling changes the saturation mole fraction at the surface, so a measured surface temperature matters even if room temperature seems stable.

Use a vapour-free reservoir and increase the surface fraction from 0.10 to 0.80. Estimate which midpoint concentration lies farther from linear interpolation. Compare the resulting flux errors and identify the physical transport term responsible.

Tutorial · recover the effective film thickness

At the same temperature and diffusivity the surface mole fraction is 0.30, the reservoir fraction is 0.05 and a balance reports \(N_A=0.050\) mol/(m² s). Estimate L. What film thickness would be inferred if the outward molar flow were ignored?

Show the two fits

Solving the exact expression gives

\[L=cD\ln(0.95/0.70)/N_A=4.90\,\mathrm{mm}.\]

The linear fit yields

\[L=cD(0.25)/N_A=4.01\,\mathrm{mm}.\]

The latter fit makes the film thinner to compensate for omitted advection. In an experiment that effective thickness would predict the wrong flux when the surface composition changes appreciably.

Further reading · Lienhard and Lienhard · A Heat Transfer Textbook, chapter 11 on mass transfer by diffusion

Measure how quickly a dielectric follows an electric field

Derive the time and frequency responses of a relaxing polarisation, locate the loss maximum and decide whether a measured sample contains more than one relaxation process.

From a delayed polarisation to a constitutive equation

A slab of insulating material is placed between parallel electrodes. At first the measured charge increases very quickly when a small voltage is switched on. It then continues to rise slowly even though the applied voltage is fixed. A constant real relative permittivity can describe the final charge but cannot predict this record. The experiment reveals at least two relevant time scales. For a measurement window that resolves only the slower process, treat the fast electronic response as instantaneous and describe the slower polarisation \(P\) by its approach to an equilibrium value.

At fixed weak field the equilibrium slow polarisation is \(\epsilon_0\Delta\epsilon E\), with \(\Delta\epsilon>0\). Assume the rate of change is proportional to the distance from that equilibrium, with one positive relaxation time \(\tau\). Then

\[\tau\dot P+P=\epsilon_0\Delta\epsilon E(t).\]

This is a phenomenological material law. Its assumptions include linear response about the prepared state, a time-independent \(\tau\), and a sample whose constituents can be described by one dominant relaxation. Testing those assumptions is part of the experiment.

For \(E(t)=E_s\) switched on at zero from an unpolarised state, solve using the integrating factor \(e^{t/\tau}\). The result is

\[P=\epsilon_0\Delta\epsilon E_s(1-e^{-t/\tau}).\]

After one \(\tau\), 63.21% of the slow response has developed; after \(3\tau\), 95.02%. Measuring an absolute fraction requires subtracting the fast initial jump and knowing the eventual plateau. A long baseline drift can look like a second relaxation if those references are not controlled.

Derive the complex dielectric response

Now use peak phasors with time dependence \(e^{-i\omega t}\). Differentiation contributes \(-i\omega\), so

\[P/E=\epsilon_0\Delta\epsilon/(1-i\omega\tau).\]

Include the high-frequency relative permittivity \(\epsilon_\infty\), where “high” means above the slow process but below additional electronic resonances. The real and imaginary parts of relative permittivity are

\[\epsilon'=\epsilon_\infty+\frac{\Delta\epsilon}{1+(\omega\tau)^2},\]
\[\epsilon''=\frac{\Delta\epsilon\,\omega\tau}{1+(\omega\tau)^2}.\]

At fixed field amplitude the polarisation current is

\[\dot P=-i\omega P.\]

The mean electrical work per unit time and volume is

\[\tfrac12\operatorname{Re}(E^*\dot P)=\tfrac12\omega\epsilon_0\epsilon''|E|^2.\]

Loss therefore has positive \(\epsilon''\) in the chosen time convention. Using \(e^{+i\omega t}\) reverses the sign of the imaginary part of permittivity but leaves mean absorbed energy positive when the current convention is changed consistently.

Set \(u=\omega\tau\). Differentiating \(u/(1+u^2)\) gives \((1-u^2)/(1+u^2)^2\). Hence \(\epsilon''\) peaks at \(u=1\), with height \(\Delta\epsilon/2\), and the real part lies halfway between its low- and high-frequency plateaux. The peak identified here is in the imaginary *permittivity*. A plot of dissipated power at fixed field includes an additional factor of frequency and need not have a peak at the same location.

Tie a frequency sweep to a step test

Suppose a material has \(\epsilon_\infty=2\), \(\Delta\epsilon=6\), and a measured loss peak at 1 kHz. Then \(\tau=1/(2\pi\,1000)\simeq159\ \mu\mathrm s\). At the peak the relative permittivity is \(5+3i\) in our convention. A time-domain voltage step should show a slow charge transient reaching 63.2% of its added charge in roughly 159 μs. This comparison connects two experiments that weight electrode offsets and parasitic impedances differently.

An independent shape check follows by eliminating \(u\). Let \(X=\epsilon'-\epsilon_\infty\) and \(Y=\epsilon''\). From the formulas \(X^2+Y^2=\Delta\epsilon X\). Thus \((X-\Delta\epsilon/2)^2+Y^2=(\Delta\epsilon/2)^2\): a single Debye relaxation traces a semicircle in the complex plane. Departures from a semicircle can reflect several relaxation times, spatially inhomogeneous samples, leakage or imperfect fixture correction. They do not uniquely identify the microscopic mechanism.

Resolve a second process only when the data require it

The synthetic sample has two groups contributing a fixed total \(\Delta\epsilon=6\). Change the fraction in the slower group and its relaxation time relative to the faster group. At equal relaxation times the groups give exactly the single-process response whatever their fractions. When the times differ, the imaginary curves broaden and may separate. Observe the real dispersion steps as well. A broad lossy peak alone can be fitted by more than one pair of times and strengths.

In a practical measurement the low-frequency tail can contain DC conductivity. In the \(e^{-i\omega t}\) convention,

\[\sigma E-i\omega\epsilon_0\epsilon E=-i\omega\epsilon_0[\epsilon+i\sigma/(\epsilon_0\omega)]E.\]

This added imaginary part is proportional to \(1/\omega\), whereas the low-frequency side of an isolated Debye relaxation rises as \(\omega\). Change electrode separation and use a DC conduction measurement to challenge the interpretation. An electrode interface can add a further time scale, so an observed fit parameter deserves an uncertainty and a physical validation step.

Tutorial

The loss maximum is at 2 kHz and its height is 4 in relative-permittivity units. The high-frequency plateau is 3. Predict the low-frequency plateau and the slow response at \(t=100\,\mu\mathrm s\) after a step.

Work through the solution

The single-time model gives \(\Delta\epsilon=8\) and the low-frequency plateau 11. The relaxation time is \(1/[2\pi(2000)]\simeq79.6\,\mu\mathrm s\). The slow fraction after 100 μs is \(1-e^{-100/79.6}\simeq0.715\). Repeat at another step amplitude to check linearity.

At the loss peak, is the phase difference between the *total* displacement and the electric field always 45°?

Work through the solution

The slow polarisation alone has a 45° phasor angle at \(\omega\tau=1\). The total displacement includes \(\epsilon_\infty E\). Its angle is \(\arctan[(\Delta\epsilon/2)/(\epsilon_\infty+\Delta\epsilon/2)]\), generally less than 45°.

Why does observing only a high-frequency tail constrain a ratio of parameters more tightly than the individual parameters?

Work through the solution

For large \(\omega\tau\),

\[\epsilon''\simeq\Delta\epsilon/(\omega\tau).\]

Many values with the same ratio \(\Delta\epsilon/\tau\) have very similar tails. Measure the peak or both plateaux to distinguish the two parameters.

Compare with material measurements

Inspect the orientational response and dielectric-loss treatment in MIT's material-properties course. Use the phasor convention of each source to predict the sign assigned to loss.

Measure equilibrium field fluctuations with a capacitor

Derive an electrical noise measurement in two ways, determine what fraction reaches a finite-bandwidth detector and use agreement to calibrate an experiment.

A zero-average voltage can store measurable energy

Connect a capacitor \(C\) across a resistor \(R\) at a uniform absolute temperature \(T\), with no external drive. Ideal circuit equations predict that any deliberately deposited charge decays on time scale \(RC\). At thermal equilibrium, microscopic fluctuations continually exchange charge and energy with the capacitor. Symmetry gives zero mean voltage, but the stored energy involves \(V^2\). In the classical limit a quadratic degree of freedom has mean energy \(k_BT/2\), giving \(\langle V^2\rangle=k_BT/C\). The resistor sets the time scale of equilibration; equilibrium mean-square voltage does not depend on resistance in this ideal model.

Check the dimensions: \(k_BT\) is an energy in joules and capacitance has units coulombs per volt. Their ratio is volts squared. At \(T=300\) K and \(C=100\) pF the RMS voltage is \(\sqrt{k_BT/C}\simeq6.44\ \mu{\rm V}\). A voltmeter that averages the signed voltage for a long time reports a value near zero. Measuring the noise requires an RMS, variance or appropriately calibrated spectral measurement.

Derive the same variance from a spectral measurement

Use a one-sided voltage power spectral density per hertz at positive frequencies. The classical Johnson–Nyquist open-circuit result for a resistor is \(S_R(f)=4k_BTR\) V²/Hz. Its square root is an amplitude spectral density in V/\(\sqrt{\mathrm{Hz}}\), not a voltage variance. Use an equivalent series voltage noise source and the RC transfer function \(H(f)=1/[1+2\pi i fRC]\). A stationary linear system multiplies the voltage power spectrum by \(|H|^2\), so

\[S_C(f)=\frac{4k_BTR}{1+(2\pi fRC)^2},\qquad\]

\int_0^\infty S_C(f)\,df=\frac{k_BT}{C}.

The integral follows by \(u=2\pi RCf\) and \(\int_0^\infty du/(1+u^2)=\pi/2\). It furnishes a detailed check on the factor four, the use of one-sided density, the conversion from hertz to angular frequency and the amplitude-versus-power distinction. If your result disagrees by a constant factor of two or \(2\pi\), audit these conventions before assigning a new noise temperature.

For \(R=10\) kΩ, \(T=300\) K, the low-frequency amplitude spectral density is approximately 12.9 nV/\(\sqrt{\mathrm{Hz}}\). The RC corner at \(C=100\) pF is \(f_c=1/(2\pi RC)\simeq159\) kHz. The open-circuit low-frequency density rises with \(R\) while the bandwidth shrinks in inverse proportion. Their integrated product gives the earlier resistance-independent variance.

Include a real observation bandwidth

Suppose a first measurement adds an ideal low-pass cutoff \(B\). The recorded fraction of equilibrium variance is \(F=(2/\pi)\arctan(B/f_c)\). Half of the noise variance lies below the RC corner. That may be surprising if the corner was introduced as the frequency at which the spectral density reaches half its zero-frequency value. These two properties coincide for this single-pole spectrum for different mathematical reasons.

At \(B=0.1f_c\), \(F\simeq0.06345\), so the recorded RMS is about 25.2% of the infinite-band RMS. At \(B=10f_c\), \(F\simeq0.93655\), giving about 96.8% of the RMS. In an experiment, taking a square root one step too early changes this comparison. A real detector transfer function replaces the sharp cutoff by an integral of \(S_C(f)|H_\mathrm{det}(f)|^2\).

Sweep the resistance by a factor ten. Observe how the corner moves along the frequency axis and how the fraction measured in a fixed bandwidth changes. Then vary temperature. In the classical regime spectral density and integrated variance are proportional to \(T\), while RMS voltage grows only as \(\sqrt T\). A plot labelled “noise” without units cannot distinguish these two dependencies.

Background · How does a longer voltage exposure alter the measured noise?

An equilibrium resistor–capacitor circuit has voltage covariance \(C_v(s)=(k_BT/C)\exp(-|s|/\tau)\), where \(\tau=RC\). Suppose a digitiser returns the mean voltage during an exposure \(T_m\). Squaring a sample of this mean measures a different variance from averaging the instantaneous voltage squared. In the classical stationary model the two-time integral becomes

\[\mathrm{var}(\bar v)=\frac{2}{T_m^2}\int_0^{T_m}(T_m-s)C_v(s)\,ds=\frac{2k_BT}{C}\frac{u-1+e^{-u}}{u^2},\]
\[u=\frac{T_m}{\tau}.\]

Short exposures recover \(k_BT/C\). At ten correlation times only about 18% of that variance remains. For very long exposures the variance decreases as \(2\tau/T_m\). Taking more closely spaced samples of one exposure cannot undo that averaging.

A physical check and a calibration check

An RC time-domain experiment provides a second observable beyond integrated power. Under the same single-pole equilibrium model the voltage autocovariance is

\[\langle V(t)V(t+\tau)\rangle=(k_BT/C)e^{-|\tau|/(RC)}.\]

Its variance at zero lag agrees with equipartition, and its decay time is obtained from the homogeneous charge-relaxation equation. Repeating the measurement with a known extra parallel capacitance lowers the RMS and lengthens the correlation time. Seeing only one of those changes suggests that the observed noise may include substantial amplifier input voltage or an independent background.

The classical approximation assumes \(hf\ll k_BT\) over the relevant band and a resistor that can be treated as frequency independent. A MHz room-temperature experiment is far inside this regime. At sufficiently high frequencies or cryogenic temperatures, a quantum noise model, an explicit definition of the measured ordering of the spectrum and the detector's energy exchange are needed. Extending an ideal classical white source to infinite frequency is only permissible as an approximation inside the convergent low-frequency RC calculation; it is not a microscopic model at arbitrarily high frequency.

Tutorial

At fixed \(C,T\), doubling \(R\) in a detector with \(B\ll f_c\) changes the measured RMS by what factor? Will the same factor apply when \(B\gg f_c\)?

Work through the solution

At very small bandwidth, \(S_C\simeq4k_BTR\) is nearly constant, so variance doubles and RMS increases by \(\sqrt2\). At large bandwidth the measurement approaches \(k_BT/C\) and becomes independent of \(R\).

A two-sided spectrum in hertz is used instead. What density and integration limits preserve the same variance?

Work through the solution

For this real voltage, the density for each sign of frequency is half the one-sided positive-frequency value. Integrate it over \((-\infty,\infty)\). Integrating the one-sided density over both signs would count the power twice.

A measured RMS is 10 μV, including independent amplifier noise of 6 μV RMS. Can 6 μV simply be subtracted to infer the sample contribution?

Work through the solution

Independent zero-mean voltages add in variance. The inferred sample RMS is

\[\sqrt{10^2-6^2}=8\ \mu\mathrm V.\]

A deterministic offset or correlated noise would require a different treatment.

Compare with an actual laboratory

The MIT Junior Lab noise experiment treats the detector as part of the measurement. Identify its calibration observable before comparing the theoretical density with an instrument reading.

Measuring magnetic core loss by a hysteresis loop and by calorimetry

A closed loop on a graph of magnetic induction against field encloses an area with units of energy per unit volume. A thermometer measures kelvins. Bring these two observations onto the same scale, account for the winding heat, and determine when the two experiments actually test the same material loss.

Infer the field and the induction from independent windings

Wind a toroidal specimen with a primary winding of \(N_p\) turns and a lightly loaded pickup of \(N_s\) turns. Let \(A\) be the representative iron cross-sectional area, \(\ell\) the mean magnetic path length and \(V_c=A\ell\) the magnetic volume. Neglect a gap and leakage initially. Ampère's law around a path through the core gives

\[H\simeq N_pi_p/\ell.\]

This relation is accurate when the toroid is slender enough that the spread of path radii is small and the pickup current is negligible. In a thick toroid \(H(r)=N_pi_p/(2\pi r)\), so one point on a nominal loop can actually represent a range of local field values.

Faraday's law supplies the second observable. Choose winding polarity so the reported voltage is

\[v_s=N_sA\,dB/dt.\]

Integrating the voltage gives the change in cross-section-averaged magnetic induction. The pickup cannot determine a constant induction offset, because static flux induces no voltage. A closed loop area is insensitive to adding a constant to \(B\) or \(H\), but a dc offset in the voltage integrates into a time-dependent ramp and prevents the reconstructed trajectory from closing. In steady periodic operation one can subtract the voltage mean over a complete period before integration. Applying that correction to a genuinely evolving magnetisation process would remove part of a real flux change.

Multiply the two measured field quantities in the appropriate order. The field work supplied per unit material volume on a small induction change is \(H\,dB\). The source term associated with the magnetising flux is \(i_p v_{p,{\rm induced}}\,dt\). Using \(v_{p,{\rm induced}}\simeq(N_p/N_s)v_s\), its value is

\[i_pN_pA\,dB=V_cH\,dB.\]

Integrating around a settled cycle gives the magnetic loss

\[W_c=V_c\oint H\,dB,\]
\[P_c=fV_c\oint H\,dB.\]

The field can absorb positive work and return some of it later in the same cycle. The area measures the algebraic remainder. Reversing the polarity of a single signal flips the loop orientation. A passively heated specimen must receive positive net energy when signs are defined for power entering the core. Simply taking the absolute value of all instantaneous products would count reversible storage twice and can grossly overestimate the heat.

Work an elliptical loop from time-domain signals

Suppose a nearly sinusoidal field is \(H=H_p\cos\omega t\) and the induction lags it by a positive angle \(\delta\), \(B=B_p\cos(\omega t-\delta)\). Differentiate the latter and multiply by \(H\). Over one cycle \(\cos\omega t\sin\omega t\) averages to zero, and \(\cos^2\omega t\) averages to one half. The resulting mean power density is \(\omega H_pB_p\sin\delta/2\), giving \(\oint H\,dB=\pi H_pB_p\sin\delta\). With zero lag the two signals trace a line and the area vanishes, even if the peak values are large. A saturation-distorted loop need not be elliptical; the original time integral remains valid with synchronised data.

Take \(H_p=120\,{\rm A/m}\), \(B_p=0.200\,{\rm T}\) and \(\delta=12^\circ\). The energy per cycle and volume is \(15.68\,{\rm J/m^3}\). A toroid with \(\ell=0.20\,{\rm m}\), \(A=2.0\times10^{-4}\,{\rm m^2}\) and \(V_c=40\,{\rm cm^3}\) dissipates \(0.627\,{\rm mJ}\) per cycle. At \(f=200\,{\rm Hz}\) its power is \(0.125\,{\rm W}\). With \(N_p=100\), the necessary current peak is \(0.240\,{\rm A}\). With \(N_s=50\), the pickup voltage has peak \(N_sA(2\pi f)B_p=2.51\,{\rm V}\). These last two predictions allow the raw oscilloscope traces to be checked before a calculated loss in watts is trusted.

For sampled periodic data use \(w=\sum_n(H_n+H_{n+1})(B_{n+1}-B_n)/2\), including the segment from the last point back to the first. This trapezoidal line integral computes an oriented polygon area. Plot the starting and ending points before adding the closing segment. Connecting widely separated endpoints by hand hides drift and can generate a fictitious wedge whose area depends on acquisition timing. Repeat at higher sampling rates to see whether corners or switching features carry appreciable extra area. When a periodic excitation has harmonics the time increment must resolve the highest significant harmonic in both measured signals.

Compare a thermal measurement with the magnetic area

Consider first a calorimeter that receives heat only from the core. Let the heat capacity of specimen, holder and sensor be \(C_{\rm eff}\). Let the leakage conductance to an ambient bath be \(G\), and let \(\Delta T=T-T_a\). The thermal balance \(C_{\rm eff}\dot{\Delta T}=P_c-G\Delta T\) predicts a steady offset \(P_c/G\) and an initial heating slope \(P_c/C_{\rm eff}\). A small thermometer lag or poor thermal contact can make the earliest measured slope misleading even though environmental losses are then small. A separate electrical heater placed where the core deposits its heat can calibrate the effective thermal response.

For \(C_{\rm eff}=20\,{\rm J/K}\), \(G=0.015\,{\rm W/K}\), and a \(2.0\,{\rm K}\) rise above ambient, the magnetic loss \(0.125\,{\rm W}\) would give a slope of about \(0.00477\,{\rm K/s}\). The heat already leaking to the bath is \(0.030\,{\rm W}\), too large to discard in a ten-percent comparison. If the winding is inside the same calorimeter, its Ohmic heat must enter the balance as well. With primary resistance \(1.50\,\Omega\) and the computed sinusoidal current, winding heating is

\[(0.240/\sqrt2)^2(1.50)=0.0432\,{\rm W}.\]

The expected slope of the combined package at the same temperature is now \(0.00693\,{\rm K/s}\). Subtraction of winding heat recovers the core result only when the estimated resistance represents the winding at its operating temperature and frequency.

A thermal estimate drawn from a whole interval is often more robust than a derivative from two adjacent temperature samples. Integrating gives

\[Q_{\rm deposited}=C_{\rm eff}[\Delta T(t_2)-\Delta T(t_1)]+G\int_{t_1}^{t_2}\Delta T\,dt.\]

Divide by the duration for mean power, then remove other measured heat sources. A drifting ambient must be recorded explicitly because the calorimeter stores energy relative to its own absolute temperature. If the core and coil equilibrate slowly with each other, a single fitted heat capacity can depend on the fitting time window. A two-temperature model or a longer dwell then supplies an independent diagnostic.

Separate reversible exchange from hysteretic and induced currents

A single measured loop at finite frequency gives the total energy dissipated by the core at that prescribed waveform and temperature. The loop can include irreversible domain processes, eddy currents and other rate-dependent effects. It does not by itself split these contributions. To probe their different scaling hold the peak induction and waveform shape fixed, then change frequency. Under a restricted low-frequency model the quasi-static hysteresis energy per cycle is approximately constant, while classical thin-lamination eddy-current power scales as \(f^2B_p^2\). Its energy per cycle therefore scales roughly as \(f\). Plotting the measured loss per cycle and volume against \(f\) tests whether such an intercept-plus-slope description fits the chosen range.

Suppose the area is \(12\,{\rm J/m^3}\) at \(100\,{\rm Hz}\) and \(20\,{\rm J/m^3}\) at \(300\,{\rm Hz}\), at the same peak induction. A straight line gives intercept \(8\,{\rm J/m^3}\) and slope \(0.040\,{\rm J\,s/m^3}\). It predicts \(16\,{\rm J/m^3}\) at \(200\,{\rm Hz}\), near the elliptical-loop calculation. Two points always determine a line. A third and fourth frequency, together with uncertainties, are required to test the law. Different losses can share similar frequency scaling over a short interval, and temperature-dependent conductivity can bend a nominally simple curve.

Use the pickup to reject the reversible part of terminal power

Measuring primary terminal voltage and current with a power analyser provides a separate electrical route to loss, but the wanted number can be a small difference between terms. The applied voltage contains winding resistance, induced magnetising voltage, leakage-inductance voltage and possible parasitic contributions. In steady periodic operation the energy stored in a fixed linear leakage inductance returns after each cycle, while winding resistance dissipates energy permanently. The secondary pickup preferentially measures the core-linked flux. Forming \(p_c(t)=(N_p/N_s)i_p(t)v_s(t)\) and averaging over a full cycle estimates core power without directly including the primary's copper voltage drop. It relies on both windings linking the same relevant flux and on negligible power drawn by the pickup.

For the elliptical example the primary magnetising voltage has peak \(5.03\,{\rm V}\) and leads the induction by ninety degrees. Its phase relative to the current is

\[90^\circ-\delta=78^\circ.\]

The core branch's apparent power is \(V_{\rm rms}I_{\rm rms}\approx0.603\,{\rm VA}\); its mean dissipative part is about \(0.125\,{\rm W}\), and the reactive part is about \(0.590\,{\rm var}\). Only the mean part contributes net heating of the magnetic volume. Including the winding voltage adds about \(0.043\,{\rm W}\) of real power to the terminal reading. A simple product of peak current and peak secondary voltage, without the turns ratio, factor one half and phase factor, has no reason to agree with either measured loss.

Consider a nearly ideal core with the same peak signals but a lag of only one degree. Its loss is about \(10.5\,{\rm mW}\), while the much larger reversible power exchange is almost unchanged. A time offset of \(10\,\mu{\rm s}\) at \(200\,{\rm Hz}\) adds \(0.72^\circ\), causing a relative loss error of approximately \(72\%\) for that small lag. Calibrate the relative channel delays using a reference signal through the actual current transducer and voltage chain, including their filters. Adjusting traces on screen until a core loop appears narrow assumes the very loss one is trying to measure. A synchronous measurement over many periods suppresses random noise but does not remove a persistent delay bias.

Test reconstruction on a waveform with a third harmonic

Let \(H(t)=H_1\cos\omega t+H_3\cos3\omega t\) while \(B(t)=B_1\cos(\omega t-\delta_1)+B_3\cos(3\omega t-\delta_3)\). With these definitions \(\delta_n\) is the phase lag of the \(n\)th harmonic in its own sinusoid. Multiplying \(H\) by \(\dot B\) and integrating over an integer number of fundamental periods eliminates products of different harmonics. Each surviving harmonic contributes the number of its own cycles in one fundamental period. The area per fundamental period is therefore \(\pi[H_1B_1\sin\delta_1+3H_3B_3\sin\delta_3]\). This identity tests whether a numerical area calculation tracks the full waveform. It does not assume that a real material is linear; here the two signals are supplied as measured periodic functions.

Use the earlier fundamental values and add \(H_3=20\,{\rm A/m}\), \(B_3=0.030\,{\rm T}\) and \(\delta_3=30^\circ\). The third harmonic contributes \(2.83\,{\rm J/m^3}\) in each fundamental period. This represents an additional \(0.0226\,{\rm W}\) for the chosen specimen and frequency. A fundamental-only sine fit would miss nearly fifteen percent of the resulting total area. An apparent jagged loop can also arise from asynchronous sampling or an offset. Distinguish genuine harmonics by checking that they are phase locked to the drive and persist under a change in sampling rate and analogue bandwidth.

Sweep phase and read the oriented loop

The live experiment reconstructs the \(H,B\) trajectory and compares it with a zero-lag reference. It uses the same peak field and induction for the two curves. At fixed peaks changing frequency leaves an assigned phase lag and therefore the prescribed energy per cycle unchanged, while watts rise with the number of cycles per second. A real core can change its lag and waveform with frequency; the graph separates this independent variable so that the meaning of the two scaled quantities is clear. Add a timing offset and predict the direction of the area error before checking its reported size. Near zero lag even the direction of an apparent loop can be controlled by a small electronic offset.

Two toroids are made of the same nominal material with equal cross sections but different mean path lengths. How should a result reported only as watts be compared?

Work through the solution

Determine actual magnetic volume for each toroid and calculate the energy per unit volume per cycle, \(P/(fV_c)\). Also check that both experienced the same induction waveform, frequency and temperature. Equal primary currents need not give equal field when the path lengths differ; equal primary applied voltages need not give equal core induction if turns, winding voltage drops or area differ. Reproducing the actual \(B(t)\) with feedback on the pickup is a more direct way to match excitation. Report dimensions and peak induction with the result so a reader can reconstruct what material condition was tested.

A saturated sample shows a small loop during a biased excitation that never crosses zero induction. Does the area formula still apply?

Work through the solution

A settled periodic minor loop encloses an area representing the net cyclic energy under exactly that bias and excursion. Adding a static induction offset does not change \(\oint H\,dB\), but the bias can alter the trajectory, differential permeability, and width of the minor loop itself. Do not infer the full major-loop energy from its area. The pickup returns only changes of induction unless an independent dc measurement or a known magnetic preparation supplies the offset. A bias winding may additionally heat the calorimeter, so include its measured power when comparing with thermal loss.

Tutorial on comparing two loss measurements

A data logger reports \(H_p\) and \(B_p\) correctly but adds an uncorrected \(10\,\mu{\rm s}\) delay to the induction channel. Estimate the fractional area error of the elliptical example.

Work through the solution

At \(200\,{\rm Hz}\) the extra apparent lag is

\[2\pi f\Delta t=0.01257\,{\rm rad}=0.72^\circ.\]

The reported area is multiplied by \(\sin(12.72^\circ)/\sin(12^\circ)\), about \(1.059\). An uncorrected delay of only one hundred-thousandth of a second overstates the core loss by about six percent. For a very low-loss specimen with much smaller physical lag, the same delay produces a far larger relative error.

A thermal run on the combined winding and core reports a slope \(0.0070\,{\rm K/s}\) at \(\Delta T=2.0\,{\rm K}\). Recover the core power and the volume-specific loss area at \(200\,{\rm Hz}\).

Work through the solution

Heat deposition in the package is

\[20(0.0070)+0.015(2.0)=0.170\,{\rm W}.\]

Subtract the estimated \(0.0432\,{\rm W}\) of winding heating to obtain \(0.1268\,{\rm W}\) in the core. Dividing by \(200\times4.0\times10^{-5}\) gives \(15.85\,{\rm J/m^3}\) per cycle. Its closeness to \(15.68\,{\rm J/m^3}\) should be evaluated against the uncertainties of heat capacity, thermal conductance, resistance, dimensions and electrical phase alignment.

Vary the magnetic circuit and identify the induction scale used by the specimen.

Optical trapping and Brownian calibration of a dielectric bead

An image of a bead remaining near a focus does not establish the strength of its trap. Derive the force pulling a small dielectric sphere into a bright region, compare it with the forward force from scattering and learn what a motion record can tell you about stiffness, drag and temperature. The model here uses an inert dielectric sphere in a homogeneous Newtonian liquid.

From two dielectric boundaries to the energy of an induced dipole

A sphere of radius \(a\) and relative permittivity \(\epsilon_b\) sits in a liquid of relative permittivity \(\epsilon_m\). Assuming the sphere is small compared with a wavelength in the liquid, solve its local electric problem in an almost uniform applied field \(E\). Rotational symmetry about the field admits an interior potential proportional to \(r\cos\theta\). The exterior consists of the imposed potential \(-Er\cos\theta\) and an induced dipolar term proportional to \(\cos\theta/r^2\). Equality of potential and of normal displacement at the surface gives the local-field and dipole factors

\[E_{\rm in}=\frac{3\epsilon_m}{\epsilon_b+2\epsilon_m}E,\]
\[p=\alpha E,\]
\[\alpha=4\pi\epsilon_0\epsilon_m a^3\frac{\epsilon_b-\epsilon_m}{\epsilon_b+2\epsilon_m}.\]

The field doing the polarising work is the external field in the host at the particle position before inserting it. To turn that work into a potential, build up the dipole from zero rather than assuming a permanent dipole moment. Quasistatic assembly gives

\[-\int_0^E\alpha E'\,dE'=-\alpha E^2/2.\]

For a harmonic peak field average the square over an optical period. In a nearly lossless liquid of refractive index \(n_m\), the peak field is related to travelling-wave intensity by \(I=n_m\epsilon_0c|E|^2/2\). The resulting conservative force is

\[U=-\frac{\operatorname{Re}\alpha}{4}|E|^2=-\frac{\operatorname{Re}\alpha}{2n_m\epsilon_0 c}I,\]
\[\mathbf F_{\rm grad}=-\nabla U .\]

The two factors of two have different origins: induced-dipole assembly and time averaging of a sinusoid. Using a permanent-dipole potential with a peak field would miss both. A bead of higher refractive index than the liquid has positive real polarizability and is attracted to increasing intensity. A lower-index inclusion reverses this local tendency. For large particles, strong absorption or rapidly structured fields, a dipole with real static polarizability no longer specifies the force; a field or multipole calculation of the complete momentum balance is required.

Investigate the small-sphere dipole response and its dependence on particle size

Compute a transverse stiffness and test how local it is

Assume the beam near its focal plane has intensity \(I(x)=I_0e^{-2x^2/w^2}\), with power \(P\), waist \(w\) defined at \(1/e^2\) intensity and \(I_0=2P/(\pi w^2)\). Put \(U_0=\operatorname{Re}\alpha I_0/(2n_m\epsilon_0c)>0\). The potential measured above its minimum is \(U_0[1-e^{-2x^2/w^2}]\). Expanding to second order and equating its leading term to \(\kappa_xx^2/2\) gives

\[\kappa_x=4U_0/w^2.\]

Stiffness therefore scales linearly with power, as the third power of sphere radius and as the inverse fourth power of waist at fixed indices. Each scaling applies within the stated approximations.

For a 40 nm radius bead with \(n_b=1.59\), take \(n_m=1.33\), \(w=0.65\) micrometres, vacuum wavelength 1064 nm, \(P=90\) mW and \(T=298\) K. The index contrast factor is 0.1252 and the waist intensity is \(1.36\times10^{11}\) watts per square metre. The predicted depth \(3.03\times10^{-20}\) J is 7.36 times the thermal energy. The lateral stiffness is \(2.87\times10^{-7}\) N/m. A displacement of 50 nm then requires approximately 14.3 fN of transverse balancing force. At a displacement of half a waist, the exact restoring force is the harmonic estimate multiplied by \(e^{-1/2}=0.607\); a Hookean calibration cannot be extrapolated that far.

Use the two curves to identify the interval in which the local quadratic energy is within ten percent of the Gaussian prediction. First lower power at fixed waist. Both curves shrink together in energy units while the harmonic thermal displacement grows. Next increase bead radius at fixed power and watch the well deepen, but also evaluate the size parameter \(2\pi n_ma/\lambda_0\). It is 0.314 at the default and grows linearly with radius. Stronger trapping predicted by this simplified model does not establish the accuracy of the dipole approximation at arbitrary sizes.

Compare axial restoring force with radiation pressure

An induced dipole reradiates a portion of the incident field. In a uniform host use the Rayleigh scattering cross section \(\sigma_s=(8\pi/3)k_m^4a^6|(\epsilon_b-\epsilon_m)/(\epsilon_b+2\epsilon_m)|^2\). In a common travelling-wave momentum-flux model for a bead in a stationary nondispersive liquid the axial scattering force is approximately \(F_s=n_m I\sigma_s/c\); absorption would add a further contribution. This estimate uses the total scattering cross section because the leading dipole pattern has vanishing mean forward cosine. For a larger forward-scattering sphere a transport cross section weights the deflected momentum instead.

In the default case the cross section is roughly \(2.05\times10^{-18}\) square metres. The forward force at the waist is about 1.23 fN. A Gaussian axial profile has \(I(0,z)=I_0/[1+(z/z_R)^2]\) with \(z_R=\pi n_mw^2/\lambda_0=1.66\) micrometres. Its local axial stiffness \(2U_0/z_R^2=2.20\times10^{-8}\) N/m is much smaller than its transverse stiffness. Balancing the constant forward force with that local stiffness predicts an equilibrium about 56 nm downstream of the waist. The small displacement relative to the Rayleigh length supports the linearisation.

Both the axial stiffness and forward scattering force scale with power in this simple model. A power sweep can thus increase confinement while barely shifting the equilibrium offset, a useful discriminating prediction. At fixed focus the offset grows rapidly with bead size because the scattering force scales with the sixth power and the gradient force with the third power. A stable lateral position alone does not establish stable three-dimensional capture. Check the axial restoring slope at a force zero and verify that thermal escape and fluid flow are negligible over the acquisition interval.

Extract stiffness from fluctuations or from a relaxation time

Near a stable point in one Cartesian direction, let \(x\) denote displacement from the mean and \(\zeta\) the viscous drag. At sufficiently low frequencies the inertial term is negligible and the overdamped Langevin equation is

\[\zeta\dot x=-\kappa x+\xi.\]

At equilibrium the fluctuating force has zero mean and white covariance \(2k_BT\zeta\delta(t-t')\) over the frequencies considered. The deterministic relaxation time is

\[\tau=\zeta/\kappa.\]

Multiplying the equation at positive delay by \(x(0)\) and averaging removes the uncorrelated later noise and gives the decaying covariance. Equipartition sets its initial value.

\[C(t)=\frac{k_BT}{\kappa}e^{-|t|/\tau},\]
\[f_c=\frac{\kappa}{2\pi\zeta},\]
\[S_x^{(1)}(f)=\frac{4k_BT\zeta}{\kappa^2+(2\pi f\zeta)^2},\quad f\ge0 .\]

The stated spectrum is one-sided in ordinary frequency. Its integral from zero to infinity equals \(C(0)\); doubling another time would double the variance. In an unbounded fluid with viscosity 1.00 mPa s, Stokes drag is \(6\pi\eta a=7.54\times10^{-10}\) N s/m. The default predicts \(f_c=60.5\) Hz and rms displacement 120 nm. The latter is roughly 0.18 waist, so the outer part of a long thermal trajectory may sample appreciable anharmonicity. A finite-depth well in an unbounded bath does not have a globally normalisable trapped equilibrium. These local equilibrium predictions apply to a sufficiently long-lived, locally sampled trapped state.

If a voltage detector gives \(V=gx\), the spectral corner and normalised autocorrelation time do not depend on the displacement gain \(g\). They determine only \(\kappa/\zeta\). Equipartition using a calibrated spatial variance gives \(\kappa\) independently of drag, provided mechanical fluctuations are in equilibrium and sufficiently resolved. If the viscosity or nearby-wall drag is uncertain, combining a known stage oscillation with the Brownian spectrum can determine further calibration quantities. Keep a stage-driven coherent peak out of the noise integral used for equipartition.

Account for exposure, sample size and unobserved motion

A camera typically reports the position averaged during an exposure of duration \(t_e\). Its variance is the double integral of the covariance over the exposure interval divided by \(t_e^2\). Evaluating the exponential local model and introducing \(u=t_e/\tau\) gives a multiplicative factor \(2(u-1+e^{-u})/u^2\). At \(u=1\) the reported physical-motion variance is only 0.736 of the instantaneous variance. Interpreting it as the full variance would overestimate stiffness by approximately 36 percent. Independent pixel-localisation noise adds additional variance with the opposite sign of bias.

Estimate that localisation noise with an effectively immobilised reference bead at a comparable brightness. Test the averaging correction by changing exposure duration at constant sampling frequency where possible. A camera that reports overlapping exposures has correlated measurement errors and needs a different covariance model. A long series of closely spaced frames also contains fewer independent thermal configurations than its frame count suggests. Compare estimates across several blocks substantially longer than the relaxation time; residual low-frequency drift can dominate even when high-frequency position precision looks excellent.

A separate check uses a known uniform liquid flow. At a steady small displacement \(x_s\), force balance gives

\[\kappa x_s=\zeta u_{\rm flow}.\]

For the default drag and stiffness a flow of 10 micrometres per second gives an offset of 26.3 nm. Repeat with reversed flow and use half the displacement difference to cancel an unknown zero-force position. Near a wall, the local flow at the bead and wall-corrected drag may differ from a stage velocity and the unbounded Stokes value. Those effects alter the mechanical calibration even if the optical field is unchanged.

A known stage oscillation calibrates position in a fluid

Brownian fluctuations alone determine the product of several unknown calibration parameters. A weak sinusoidal translation of the sample cell adds a known mechanical signal at a chosen frequency. Work in laboratory coordinates with a fixed optical trap and with fluid moving uniformly at velocity \(u(t)\) near the bead, well away from walls in the idealised model. The drag is now \(-\zeta(\dot x-u)\). Superposing a stage displacement \(A\cos\omega t\) on thermal fluctuations gives a deterministic response whose complex amplitude satisfies \((\kappa-i\omega\zeta)\widetilde x=-i\omega\zeta A\) in the negative-exponential convention. Therefore its amplitude ratio is

\[\frac{|\widetilde x|}{A}=\frac{\omega\tau}{\sqrt{1+\omega^2\tau^2}} .\]

At the trap corner the bead displacement amplitude is the known stage amplitude divided by the square root of two. A calibrated 80.0 nm stage oscillation there produces a predicted bead amplitude of 56.6 nm. If a position-sensitive receiver records a coherent peak amplitude of 0.170 V, its displacement gain is 3.01 mV/nm. At very low drive frequencies the fluid velocity is small for fixed stage amplitude and the trap holds the bead nearly stationary. At high enough frequency the bead follows the fluid displacement within the overdamped model, but finite hydrodynamic, optical and electronic bandwidths eventually matter.

After determining the gain, convert the surrounding voltage spectrum into spatial units and use the area of the stochastic fluctuation spectrum to find stiffness. Exclude the calibrated line and account for the finite spectral averaging window; a narrow drive that leaks into neighbouring bins can inflate the inferred thermal variance. Dividing measured stiffness by the independently determined corner rate then gives drag, which can be compared with the known viscosity and sphere radius. This avoids assuming free-space Stokes drag in the first step of a near-wall measurement.

There are two limiting systematic effects that a good fit to a single drive frequency cannot resolve. A frequency-dependent stage calibration changes the actual fluid displacement, and motion of the optics relative to the cell generates a direct detector background even with the bead immobilised. Repeat the drive above and below the corner, compare coherent phase as well as amplitude and acquire a trapped and immobilised reference. Correct conversion should explain the entire complex response with one spatial gain and one corner time. A single calibration number obtained at one frequency can hide a phase lag in the stage controller or in the optical position channel.

One last cross-check reverses the stage drive phase by half a period. The coherent bead response must reverse, while thermal background power remains unchanged. A component that fails this reversal could come from ambient vibration unrelated to the stage. Averaging the two traces with and without a sign change separates these contributions before either is used in an optical-force calibration.

Tutorial · Separate a unit-conversion error from excess noise

In a single-axis trap at 298 K a calibrated detector reports a variance of 2500 square nanometres after removal of localisation noise and exposure correction. An independent spectral fit gives a corner of 175 Hz. Infer stiffness, drag and the equivalent unbounded hydrodynamic radius for a liquid of viscosity 1.00 mPa s. Compare against a nominal 80 nm radius bead.

Infer the three quantities and test their consistency

A nanometre squared is \(10^{-18}\) square metres, so the variance is \(2.50\times10^{-15}\) square metres. Equipartition gives \(1.65\times10^{-6}\) N/m. Dividing by \(2\pi f_c\) gives drag \(1.50\times10^{-9}\) N s/m and radius \(\zeta/(6\pi\eta)=79.5\) nm. The agreement supports the local overdamped description under the assumed temperature and viscosity. Forgetting the factor of \(2\pi\) would predict a radius roughly six times larger and could be mistaken for a huge near-wall correction.

Now imagine that additional uncorrelated read noise had been left in the variance. This raises apparent variance, lowers the equipartition stiffness and would lower the inferred drag at the same fitted corner. Nearby-wall drag for a given radius instead normally raises hydrodynamic resistance for parallel translation. Their effects on the inferred radius thus differ in sign under the stated assumptions. Varying height and independently calibrating the measurement noise are appropriate diagnostics before attributing a discrepancy to bead dimensions.

Tutorial · Test a force-law inference with power and concentration controls

At fixed bead radius a trap is operated at two powers differing by a factor of two. Measured corner frequencies increase from 42 to 84 Hz, but rms displacement falls only from 110 to 87 nm. What does the harmonic model with fixed drag and temperature predict? Estimate a power-independent additive position-noise variance that could reconcile the two readings.

Use two variances to separate scale and offset

The doubled corner gives doubled stiffness if drag is unchanged. Physical thermal variance should halve. The predicted rms at higher power would be 77.8 nm if the lower-power value were entirely physical. Let the low-power measured variance be \(v+b\) and the high-power one \(v/2+b\), where \(b\) is a constant additive noise variance. Solving from 12,100 and 7,569 square nanometres gives \(v=9062\) and \(b=3038\) square nanometres, or approximately 55.1 nm rms noise.

This is a large inferred detector noise and demands an independent immobilised reference check. Power-dependent heating of the liquid changes temperature and viscosity, so an unchanged product inferred from only two quantities cannot prove that heating is absent. Test several powers, reverse their order to reveal slow drift and vary bead concentration to exclude overlapping particles in the tracking window. The inferred additive term should remain constant across those controls if it comes from the specified detector model.

Tolić-Nørrelykke and colleagues · position and force calibration using thermal and driven measurements

How an unobserved environment changes a quantum state

Model a qubit and a two-state environment by a joint unitary. Derive channels, the continuous-time master equation and the relation between longitudinal and transverse relaxation. A recorded event and an unread detector produce different conditional predictions.

Derive loss of coherence from a larger unitary system

A qubit prepared in \(\alpha|0\rangle+\beta|1\rangle\) interacts with an environment initially in \(|e\rangle\). A joint unitary correlates \(|0,e\rangle\to|0,e_0\rangle,\ |1,e\rangle\to|1,e_1\rangle\), with both environmental states normalised. The joint output is a pure state. Its qubit density matrix follows by tracing over a complete environment basis. Populations stay \(|\alpha|^2,|\beta|^2\). The off-diagonal entry is \(\alpha\beta^*\langle e_1|e_0\rangle\). Orthogonal environment records remove coherence from all local qubit observations; identical records leave its magnitude intact. Partial distinguishability gives a continuous range in between. Energy need not flow in this controlled dephasing model. An observed reduction in fringe contrast can arise from entanglement with unobserved degrees of freedom even when total evolution is unitary.

Consider instead amplitude loss from an excited qubit to an initially empty environment mode:

\[|0,0_e\rangle\mapsto |0,0_e\rangle,\qquad |1,0_e\rangle\mapsto\sqrt{1-p}|1,0_e\rangle+\sqrt p|0,1_e\rangle .\]

The two output states remain orthogonal and unit-normalised, so this map on the prepared environment subspace can be extended to a unitary on the full joint space. If environment state \(k\) is unobserved, sum the associated unnormalised alternatives in density-matrix form:

\[\rho'=\sum_kK_k\rho K_k^\dagger.\]

Here \(K_0=|0\rangle\langle0|+\sqrt{1-p}|1\rangle\langle1|\) and \(K_1=\sqrt p|0\rangle\langle1|\). Since \(\sum K_k^\dagger K_k=I\), trace is preserved. The excited population obeys \(\rho_{11}'=(1-p)\rho_{11}\) and the coherence \(\rho'_{01}=\sqrt{1-p}\rho_{01}\). Averaging state vectors before forming outer products would introduce interference between orthogonal environmental records that have already been traced out.

Take a controlled infinitesimal limit

In a memoryless approximation each small interval \(dt\) meets a fresh environment record with vanishing probability of a previously lost excitation returning. Let jump operators \(L_j\) have units \(1/\sqrt{\mathrm s}\), set \(K_j=\sqrt{dt}\,L_j\) for events and \(K_0=I-dt(iH/\hbar+\sum L_j^\dagger L_j/2)\). Expanding the completeness relation shows trace preservation through first order in \(dt\). Expand \(\sum K_k\rho K_k^\dagger-\rho\), divide by \(dt\) and keep the finite terms:

\[\frac{d\rho}{dt}=-\frac i\hbar[H,\rho]+\sum_j\left(L_j\rho L_j^\dagger-\tfrac12 L_j^\dagger L_j\rho-\tfrac12 \rho L_j^\dagger L_j\right).\]

The first term of each dissipative bracket adds probability after an event and the anticommutator subtracts probability from the no-event branch. Their traces cancel. This construction is completely positive, meaning that the same local channel remains positive even when tensored with identity on an unused entangled ancilla. Positivity only on isolated input states would be too weak: transposition maps density matrices to density matrices on a single system, yet partial transposition can produce a negative eigenvalue when applied to half an entangled pair. The Lindblad form embodies the relevant stronger constraint for the assumed Markovian dynamics.

Independent loss and pure dephasing can be represented by \(L_1=\sqrt{\Gamma_1}|0\rangle\langle1|\),

\[L_\phi=\sqrt{\Gamma_\phi/2}\,\sigma_z.\]

The factor one half in the dephasing operator fixes our convention for \(\Gamma_\phi\). Direct substitution gives \(\dot\rho_{11}=-\Gamma_1\rho_{11}\), while \(\dot\rho_{01}\) acquires \(-(\Gamma_1/2+\Gamma_\phi)\rho_{01}\) in addition to its Hamiltonian phase. Thus

\[T_1=\Gamma_1^{-1},\]
\[T_2^{-1}=(2T_1)^{-1}+\Gamma_\phi .\]

At zero temperature with these mechanisms, \(T_2\le2T_1\). This upper bound is tied to definitions and assumptions. A broad ensemble with static detuning spread, a driven nonequilibrium sample or a refocused pulse sequence may yield an observed envelope with a different shape and timescale. Fitting every contrast decay with one exponential and interpreting that number as the homogeneous \(T_2\) can assign an unphysical dephasing rate.

Update a state when an individual event is recorded

If an ideal detector reports branch \(j\), the probability is \(p_j=\operatorname{tr}K_j\rho K_j^\dagger\), and the normalised conditional output is \(K_j\rho K_j^\dagger/p_j\). The conditional evolution depends on which environment observable is measured; summing outcomes gives the same physical unconditioned channel. In the loss model, detecting one emission places the qubit in its ground state. Absence of an emission also carries information. At finite duration \(t\), no emission acts by \(K_0=|0\rangle\langle0|+e^{-\Gamma_1t/2}|1\rangle\langle1|\) for the simple undriven zero-temperature case.

From initial \((|0\rangle+|1\rangle)/\sqrt2\), at \(t=T_1\ln2\) the no-event probability is

\[(1+1/2)/2=3/4.\]

Conditional excited probability is

\[(1/2)/(1+1/2)=1/3.\]

With the event branch in the ground state, the unconditioned excited probability is \((3/4)(1/3)=1/4\), agreeing with exponential decay of its initial one half. Repeatedly renormalising only no-event trajectories and calling their mean the ensemble population would overestimate survival. If the event detector misses photons, “no click” groups genuine no-emission with undetected emissions and its conditional state is generally mixed.

Use heating and cooling to infer the reservoir

Allow upward and downward transitions at rates \(\Gamma_\uparrow,\Gamma_\downarrow\). Rate equations give

\[\dot p_1=\Gamma_\uparrow(1-p_1)-\Gamma_\downarrow p_1,\]
\[p_{1,\infty}=\frac{\Gamma_\uparrow}{\Gamma_\uparrow+\Gamma_\downarrow},\quad\]
\[p_1(t)=p_{1,\infty}+[p_1(0)-p_{1,\infty}]e^{-(\Gamma_\uparrow+\Gamma_\downarrow)t}.\]

Both upward and downward rates contribute half their sum to coherence decay. If the reservoir is in thermal equilibrium, detailed balance gives

\[\Gamma_\uparrow/\Gamma_\downarrow=e^{-\hbar\omega/(k_BT)}.\]

The population relaxation time measures their sum and equilibrium population measures their ratio, allowing a substantive check of a proposed bath temperature. The relation is a thermodynamic assumption in addition to the two-state rate model. A pumped bath can have the same measured relaxation time with an entirely different stationary population.

For a 5.00 GHz transition, \(\hbar\omega/k_B=h(5\,\mathrm{GHz})/k_B\simeq0.240\) K. A stationary excited fraction 0.10 would imply \(T=0.240/\ln9=0.109\) K under equilibrium. With population relaxation 20 μs the sum of rates is \(5.0\times10^4\,\mathrm{s^{-1}}\), giving 5000 upward and \(45\,000\) downward transitions per second for the respective source populations. Verified independent upward and downward preparations test more than fitting the decay of an initially excited state alone.

Discriminate static detuning, Markovian dephasing and coherent error

A Ramsey experiment prepares an equal superposition, allows free evolution for time \(t\), then converts relative phase to a population by a final analysis pulse. If the detuning \(\delta\) is fixed in each run but varies randomly between runs, then the ensemble coherence is multiplied by the characteristic function \(C(t)=\int p(\delta)e^{-i\delta t}d\delta\). Here \(\delta\) is an angular frequency. For a Gaussian detuning of mean \(\delta_0\) and standard deviation \(\sigma\),

\[C=e^{-i\delta_0t}e^{-\sigma^2t^2/2}.\]

A uniform detuning offset shifts fringe phase without reducing the contrast of a fully coherent, identically repeated preparation. A Lorentzian distribution yields an exponential envelope which can resemble homogeneous Markovian dephasing in a simple time scan. The fitted functional form alone may therefore fail to identify the physical cause of lost contrast.

An ideal instantaneous \(\pi\) pulse about \(x\) halfway through free evolution reverses the effect of a static \(z\)-detuning on relative phase: \(e^{-i\delta t\sigma_z/4}\sigma_x e^{-i\delta t\sigma_z/4}=\sigma_x\), since \(\sigma_x\) anticommutes with \(\sigma_z\). All static offsets refocus at the echo. Independent white Markovian dephasing accumulated in each half is uncorrelated and cannot be undone in this way. The deterministic Hamiltonian error and a rapidly fluctuating environment can share a short Ramsey contrast while giving different echo contrasts. If the pulse itself has finite duration or an angle error, the algebraic cancellation is no longer exact; repeating at two pulse powers tests that particular assumption.

Take \(\sigma/2\pi=20.0\) kHz and negligible damping. At \(t=10.0\,\mu\mathrm s\) the free Ramsey contrast from Gaussian detuning alone is

\[e^{-(1.257)^2/2}=0.454.\]

An ideal echo returns unity. Add independent \(T_1=80\,\mu\mathrm s,\ T_\phi=50\,\mu\mathrm s\). The homogeneous coherence time is

\[[1/(160\,\mu{\rm s})+1/(50\,\mu{\rm s})]^{-1}=38.1\,\mu\mathrm s.\]

The expected echo contrast is now \(e^{-10/38.1}=0.769\) and the ordinary Ramsey contrast \(0.349\). A single fitted \(T_2^*\) cannot display these three separate timescales. Measuring populations, Ramsey fringes and echoes on consistent ensembles gives three complementary observables with independently interpretable limits.

For a time-dependent classical detuning \(\delta(t)\), pulse sequences choose a modulation \(y(t)=\pm1\) multiplying the noise phase. The phase error is

\[\phi=\int y(t)\delta(t)dt.\]

For stationary zero-mean Gaussian noise, \(\langle e^{-i\phi}\rangle=e^{-\langle\phi^2\rangle/2}\) and the variance is a double integral of the noise correlation weighted by \(y(t)y(t')\). Equivalently it is the spectral integral of the power density weighted by \(|\int y(t)e^{i\omega t}dt|^2\), with the normalisation set by the chosen two-sided Fourier convention. A single echo has zero weight at \(\omega=0\) because its two half integrals cancel, while keeping finite-frequency sensitivity. Families of pulse spacings can therefore probe noise timescales rather than simply fitting larger and larger numbers to a nominal coherence time.

Find the damped saturation curve from optical Bloch equations

A continuously driven qubit has an additional route to separate population and coherence relaxation. In a rotating frame let \(H=\hbar(\Omega\sigma_x+\Delta\sigma_z)/2\), with \(z=p_e-p_g\), equilibrium \(z_{\rm eq}=-1\) at zero temperature, and transverse damping \(1/T_2\). Choose a consistent Bloch basis so the commutator gives the cross product of \((\Omega,0,\Delta)\) with \((x,y,z)\). The equations are

\[\dot x=-\Delta y-x/T_2,\]
\[\dot y=\Delta x-\Omega z-y/T_2,\]
\[\dot z=\Omega y-(z-z_{\rm eq})/T_1 .\]

At steady state the first equation gives

\[x=-\Delta T_2 y.\]

The second then gives

\[y=-\Omega T_2 z/(1+\Delta^2T_2^2).\]

Inserting into the third gives

\[z=z_{\rm eq}/[1+\Omega^2T_1T_2/(1+\Delta^2T_2^2)].\]

Thus the excited fraction for \(z_{\rm eq}=-1\) is

\[p_{e,\infty}=\frac{\Omega^2T_1T_2}{2[1+\Delta^2T_2^2+\Omega^2T_1T_2]}.\]

A weak resonant drive gives a population proportional to its power, and a strong continuous drive saturates toward one half rather than preparing a permanently inverted state. Coherent \(\pi\)-pulse inversion is a transient unitary process; continuous steady balance with relaxation gives a different preparation. The full angular-frequency width at half of the on-resonance excitation is \(2\sqrt{1+\Omega^2T_1T_2}/T_2\), so increasing power broadens the line even at unchanged intrinsic \(T_2\).

Choose \(T_1=20\) μs, \(T_2=16\) μs and resonant \(\Omega/2\pi=10\) kHz. The saturation parameter is

\[s=\Omega^2 T_1T_2=1.26.\]

The stationary excited fraction is \(s/[2(1+s)]=0.279\), and the ordinary-frequency full width is

\[\sqrt{1+s}/(\pi T_2)=29.9\,\mathrm{kHz}.\]

At very low drive it would be 19.9 kHz. A measured linewidth that increases approximately as the square root of power at high drive can have this coherent saturation origin without any increase in the environment's pure-dephasing rate. Comparing the zero-power linewidth extrapolation with an independent time-domain \(T_2\) is a stronger test than fitting a single apparent line broadening.

Connect an individual event stream to an ensemble lifetime

The lifetime \(T_1\) of one excited qubit is a distribution of observed emission times across many trials. With perfect detection, no drive and initially excited state, survival \(S(t)=e^{-\Gamma t}\) implies waiting-time density \(w(t)=-dS/dt=\Gamma e^{-\Gamma t}\). The mean waiting time and standard deviation are both \(1/\Gamma\). A no-click trajectory stays in the excited state conditionally until its first emission when the initial preparation is certainly excited. Its unnormalised weight decays exponentially, but assigning every no-click trajectory a continuously decreasing normalised excitation would confuse conditional and unconditioned statements. For an initial superposition the absence record instead changes the normalised state as derived earlier.

Real acquisitions may stop each trial at a fixed deadline \(T_{\rm stop}\). Treating all no-click trials as though they emitted exactly at the deadline biases lifetime inference. For \(n\) observed emissions at times \(t_j\) and \(m\) censored trials with no emission through \(T_{\rm stop}\), the likelihood is proportional to \(\prod_{j=1}^n\Gamma e^{-\Gamma t_j}\prod_{k=1}^m e^{-\Gamma T_{\rm stop}}\). Optimising gives

\[\hat\Gamma=n/(\sum_j t_j+mT_{\rm stop}).\]

The numerator is actual events and the denominator all time observed at risk. For 40 detections totalling 480 μs and 10 additional censored runs each observed 30 μs, the estimate is \(40/780=0.0513\,\mu\mathrm s^{-1}\), or \(T_1\simeq19.5\,\mu\mathrm s\). Discarding the censored runs instead would report 12 μs from the mean detected delay. This statistical correction follows directly from the same physical survival law used for the quantum channel.

Detection inefficiency can cause a different data problem. In a single-excitation undriven trial, a missed decay leaves a qubit in its ground state and unable to emit again. The probability of no registered event up to \(t\) is \(1-\eta[1-e^{-\Gamma t}]\) at constant efficiency \(\eta\), with a nonzero late plateau \(1-\eta\). It is not \(e^{-\eta\Gamma t}\), which would describe thinning a renewable stationary Poisson event stream. Long-time survival of the recorded count and independent final-state readout can distinguish a missed emission from a genuinely long-lived excitation. This example shows why the detector model must specify whether events can repeat after one has been missed.

Audit a reconstructed Pauli noise channel

Suppose three independently prepared Bloch components appear to shrink by factors \(\lambda_x,\lambda_y,\lambda_z\) after a calibrated waiting time, with no displacement of the centre. A diagonal unital qubit channel can be written \(\mathcal E(\rho)=\sum_{\nu=0,x,y,z}p_\nu\sigma_\nu\rho\sigma_\nu\) for a physical Pauli mixture. Expanding its action on the three axes and inverting gives

\[p_0=(1+\lambda_x+\lambda_y+\lambda_z)/4,\]
\[p_x=(1+\lambda_x-\lambda_y-\lambda_z)/4,\]

with cyclic partners for \(p_y,p_z\). Complete positivity demands all four numbers be nonnegative. Checking each \(|\lambda_i|\le1\) only checks lengths along single Bloch axes and, for this diagonal map, positivity on a single qubit. It does not guarantee that the reconstructed operation is consistent on half of an entangled system.

For \(\lambda=(0.9,0.9,0.5)\), every axis appears to shrink, yet \(p_z=(1-0.9-0.9+0.5)/4=-0.075\). Thus the exact diagonal unital channel inferred from those numbers is not completely positive. Finite measurement noise, neglected affine offsets or changing preparation could be responsible. Compare the fit with uncertainty regions and a constrained process model; simply forcing each measured contraction coefficient into \([-1,1]\) cannot repair this violation. As a constructive control, \(\lambda=(0.8,0.7,0.6)\) gives \(p_0=0.775,\ p_x=0.125,\ p_y=0.075,\ p_z=0.025\), all valid and summing to one. A simulator using these four random Pauli operations on entangled inputs then supplies a direct check of the estimated channel beyond single-qubit positivity.

Test how a coherence measurement depends on an ensemble

Compare quasistatic frequency spread with homogeneous decay in a Ramsey sequence. Identify which further measurement could distinguish the mechanisms.

Prove when two different event descriptions give the same channel

A given unconditioned quantum operation does not determine a unique set of environmental records. Suppose a set of Kraus operators \(K_j\) describes a channel. If an environment detector resolves an alternative orthonormal basis related by unitary \(U=(u_{\alpha j})\), its new system operators are \(\tilde K_\alpha=\sum_j u_{\alpha j}K_j\). Summing the unnormalised conditional outputs gives

\[\sum_{\alpha,j,k}u_{\alpha j}u_{\alpha k}^*K_j\rho K_k^\dagger=\sum_jK_j\rho K_j^\dagger.\]

This calculation explains why environment-dependent state trajectories can be quite different while every unconditioned prediction on the system agrees. A simulator's choice of individual jump records only describes a particular monitoring scheme when the environment observable actually corresponds to those records.

Consider complete dephasing in the \(z\) basis. One representation is \(K_0=|0\rangle\langle0|,\ K_1=|1\rangle\langle1|\), an ideal path measurement with its result forgotten. Rotate the two environment labels by the Hadamard matrix to obtain

\[\tilde K_+=(I/\sqrt2),\ \tilde K_-=(\sigma_z/\sqrt2).\]

These describe equally likely identity or phase-flip operations. For input \(|+x\rangle\), the first recorded instrument conditionally gives \(|0\rangle\) or \(|1\rangle\); the second gives \(|+x\rangle\) or \(|-x\rangle\). Both produce \(I/2\) if their outcome is ignored. For initial \(|0\rangle\) the first record is deterministic, while the second remains equally random and leaves the state unchanged up to a phase. Measuring only the system after discarding the labels cannot tell which set was used, but correlations with a retained environmental measurement can immediately tell them apart.

The same distinction is useful for a partially dephasing environment. If \(|0\rangle,|1\rangle\) become correlated with environment states of real overlap \(c\), the qubit's transverse Bloch vector contracts by \(c\). For \(-1\le c\le1\) a random phase-flip representation has probabilities \(p_I=(1+c)/2,\ p_Z=(1-c)/2\). For \(c<0\) a fringe phase reversal accompanies partial contraction; a reported positive “visibility” loses that sign. One can separate a deterministic phase rotation from the magnitude of random or entangling dephasing if the phase reference is maintained. Over independent identical intervals a real \(c\) multiplies repeatedly; the coherence after \(n\) steps is \(c^n\). If the same randomly chosen phase flip is instead held fixed throughout all intervals, successive errors are correlated and the even-step coherence can return to one. A single-step channel tomography cannot identify the environmental memory shared across steps.

Tell apart a memoryless phase-flip channel and a fixed hidden phase

Both devices individually implement \(p_Z=0.20\) over a calibrated interval for freshly prepared qubits. In device A the phase-flip draws at successive intervals are independent. In device B one draw is held fixed for both consecutive intervals. Predict \(+x\) readout after one and two intervals for an initial \(|+x\rangle\).

Derive and check the result

One interval leaves \(x=1-2p_Z=0.60\), so both devices give

\[P(+x)=0.80.\]

Independence in A gives \(x=0.60^2=0.36\) after two intervals, or \(P(+x)=0.68\). For B, two identical phase flips multiply to identity whether the hidden choice was identity or \(Z\), hence \(P(+x)=1\). In both devices the one-step process applied to an independently prepared ensemble is consistent with the measured completely positive map. Composing that map twice implicitly assumed fresh, independent environment conditions; a memory experiment tests exactly that assumption. Observing a revival thus need not imply an energy input, a negative probability or a nonunitary failure in the larger coupled system.

Distinguish dipole coherence from an excited-state population lifetime

Consider a single initially excited emitter in a memoryless zero-temperature environment with radiative population decay \(\Gamma\) and no additional dephasing. The probability density of emitting at time \(t\ge0\) is \(\Gamma e^{-\Gamma t}\). A normalised single-photon temporal mode consistent with this ideal undistinguished radiative channel is \(g(t)=\sqrt{\Gamma}\,e^{-\Gamma t/2}e^{-i\omega_0t}\) on \(t\ge0\). Its field amplitude decays twice as slowly as the population probability. Use the Fourier convention \(\tilde g(\omega)=(2\pi)^{-1/2}\int g(t)e^{i\omega t}dt\). The half-line exponential integral gives

\[|\tilde g(\omega)|^2=\frac{\Gamma}{2\pi[(\Gamma/2)^2+(\omega-\omega_0)^2]} .\]

It integrates to one in angular frequency. At a detuning of \(\Gamma/2\) the intensity has half its peak, so the full angular-frequency linewidth is \(\Gamma\), or \(\Gamma/(2\pi)\) in hertz. Using the population decay directly as a field amplitude would predict a linewidth twice too large and the wrong wave-packet envelope. The transform-limited result requires a single radiative mode in the sense of a pure emitted temporal state and absence of additional phase randomisation. Extra pure dephasing broadens the spectrum while population decay may remain unchanged.

For \(\Gamma^{-1}=10.0\) ns the ideal linewidth is 15.9 MHz. Add independent homogeneous pure dephasing at \(\Gamma_\phi=2.0\times10^7\ \mathrm{s^{-1}}\). The first-order dipole correlation decays at \(\Gamma/2+\Gamma_\phi\), giving a full line width \((\Gamma/2+\Gamma_\phi)/\pi=22.3\) MHz. The photon detection time distribution can still have 10 ns decay. A measured line twice its nominal transform-limited width might indicate pure dephasing, but spatially varying frequencies, slow source drift or spectral resolution can also broaden the observed distribution. A lifetime measurement alone does not calibrate those effects.

The acquisition window has an independently calculable consequence. If only photons arriving before time \(T\) are retained, their normalised temporal mode is a truncated exponential divided by \(\sqrt{1-e^{-\Gamma T}}\) in this ideal pure-emission model. Its Fourier amplitude gains factor \(1-e^{-[\Gamma/2-i(\omega-\omega_0)]T}\) in the numerator. At \(T\ll1/\Gamma\) the shape approaches the squared sinc of a short rectangular temporal window. Selecting only early photons can thus broaden the spectrum even though the emitter and its environment are unchanged. A time gate, an energy filter and unconditioned counting describe different optical preparations and different uncertainty budgets.

Infer the transform-limited fraction from a linewidth and test the model

A homogeneous line has measured weak-drive full width 25.0 MHz and population lifetime 10.0 ns. Compute \(T_2\) and the implied pure dephasing rate assuming ideal Lorentzian broadening. Which second measurement would discriminate this inference from static sample inhomogeneity?

Derive and check the result

With angular half width \(1/T_2\), the frequency full width is \(1/(\pi T_2)\), so \(T_2=12.73\) ns. Subtracting \(1/(2T_1)=5.00\times10^7\ \mathrm{s^{-1}}\) from \(1/T_2=7.85\times10^7\ \mathrm{s^{-1}}\) gives

\[\Gamma_\phi=2.85\times10^7\ \mathrm{s^{-1}}.\]

The coherence relative to the radiative limit is

\[T_2/(2T_1)=0.637.\]

Compare a time-domain echo, a single-emitter linewidth or spectra over short acquisition segments with the ensemble line. A recoverable component of contrast or slowly wandering line centres would indicate a static or slow contribution instead of assigning every megahertz to homogeneous phase damping.

Tutorial · distinguish different sources of coherence loss

Recover a pure-dephasing rate and assess a conflicting fit

A population measurement gives

\[T_1=30.0\,\mu\mathrm s;\]

homogeneous Ramsey contrast gives

\[T_2=24.0\,\mu\mathrm s.\]

Find \(T_\phi\). What would a reported \(T_2=80\,\mu\mathrm s\) imply in the same model?

Work through the solution

Subtract \(1/(60\,\mu{\rm s})\) from \(1/(24\,\mu{\rm s})\) to get \(\Gamma_\phi=0.0250\,\mu{\rm s}^{-1}\), hence \(T_\phi=40.0\,\mu\mathrm s\). Replacing 24 by 80 yields a negative pure dephasing rate, incompatible with the specified independent time-homogeneous channels. Check the fitted envelope, uncertainties, thermally shifted equilibrium population and whether the two times were measured under comparable conditions. A negative fitted number is evidence about the model or data interpretation, not a physically negative random-event rate.

Calculate an inefficient no-click update

The initial excited probability is one half, the decay probability for an initially excited qubit during the window is 0.40, and a true emitted excitation is detected with efficiency 0.75. Find the probability of no click, its conditional excited fraction and the unconditioned population.

Work through the solution

A real emission occurs with probability \(0.5\times0.40=0.20\); a click is seen with probability 0.15, so no click has probability 0.85. Remaining excited and no click occurs with probability \(0.5(1-0.40)=0.30\). Conditional excitation is \(0.30/0.85=0.3529\); the unconditioned excitation is 0.30 since clicked branches are ground. For an initially coherent preparation the no-click off-diagonal term must also be updated by grouping the undetected-emission and true-no-emission Kraus outcomes. Simply replacing \(p\) by detector efficiency times \(p\) would predict the wrong physical excitation loss.

Diagnose a nonphysical time step and repair it

Apply one forward-Euler step to \(\dot p_1=-\Gamma p_1\) with initially excited state and \(\Gamma\Delta t=1.2\). Compute the prediction and an exact completely positive alternative. Would enforcing unit trace fix Euler's failure?

Work through the solution

Euler gives \(p_1=1-1.2=-0.2,\ p_0=1.2\), already with exact trace one. The finite-time amplitude-damping channel has \(p=1-e^{-1.2}=0.6988\), giving \(p_1=0.3012\). For this simple model the exact Kraus step can be applied repeatedly at arbitrary duration. In a driven model an operator-splitting scheme with unitary Hamiltonian substeps and completely positive damping substeps maintains positivity while introducing a controllable splitting error. Check convergence by halving the step and comparing with an independent observable. Renormalising trace or clipping a negative eigenvalue changes the numerical trajectory without diagnosing the original time-step error.

Further reading

Recover a transition frequency from two separated pulses

A two-level system is driven by two short pulses with a free evolution interval between them. Determine why a population measurement carries phase information. Use a scan at several delays to separate a constant detuning, intrinsic coherence loss and trial-to-trial frequency variation.

Follow the amplitudes through both pulses

Use basis \(|g\rangle,|e\rangle\). Let the first pulse prepare \((|g\rangle+|e\rangle)/\sqrt2\) in the frame of the applied oscillator. A detuning \(\Delta\) in radians per second accumulates a relative phase \(\Delta\tau\) in free time \(\tau\). Immediately before the second pulse each state has population one half; measuring population here cannot reveal detuning. Choose a second pulse equivalent to projecting onto \((|g\rangle+e^{-i\phi}|e\rangle)/\sqrt2\). Then one output population is

\[P(\tau,\phi)=\tfrac12[1+\cos(\Delta\tau-\phi)].\]

The sign of the phase follows our definitions of detuning and the reference pulse. Shifting the reference phase makes it possible to check that sign. A measurement using only \(\phi=0\) cannot distinguish \(\Delta\) from \(-\Delta\). Coherence is the off-diagonal density-matrix element that the second pulse converts into an observable population difference.

Derive two envelopes with different origins

A homogeneous decay time \(T_2\) multiplies the off-diagonal element by \(e^{-\tau/T_2}\). If instead the detuning of each experimental shot is constant during that shot and drawn from a Gaussian distribution of mean \(\bar\Delta\) and standard deviation \(\sigma_\Delta\), average the complex phase, not its absolute value. Completing the square in the Gaussian integral gives

\[\langle e^{i\Delta\tau}\rangle=e^{i\bar\Delta\tau}e^{-\sigma_\Delta^2\tau^2/2}.\]

With both independent mechanisms the measured contrast is \(C(\tau)=\exp[-\tau/T_2-\sigma_\Delta^2\tau^2/2]\). One mechanism gives an initial logarithmic slope, the other adds curvature. A single low contrast measured at just one delay cannot establish which one caused it.

Infer parameters from quadratures and a frequency scan

Record the \(\phi=0,\pi/2\) outputs, then form \(X=2P_0-1=C\cos(\bar\Delta\tau)\) and \(Y=2P_{\pi/2}-1=C\sin(\bar\Delta\tau)\). Their length estimates contrast and their angle estimates accumulated phase modulo \(2\pi\). Suppose at \(0.50\,\mathrm{ms}\) the readings are 0.500 and 0.850. Then \(X=0,\ Y=0.700\), and the phase is \(\pi/2\) modulo \(2\pi\). With an independent bound \(|\bar\Delta/2\pi|<1\,\mathrm{kHz}\), the implied cyclic detuning is \(+500\,\mathrm{Hz}\). Longer delays resolve fine frequency differences at the cost of phase ambiguity and declining contrast. Use a shorter-delay record to unwrap a longer one.

At a contrast of 0.700 the relation \(-\ln(0.700)=\tau/T_2+\sigma_\Delta^2\tau^2/2\) supplies one equation for two unknowns. Several delays, with independent error bars, are needed to identify the linear and quadratic terms. At very low signal the length \(\sqrt{X^2+Y^2}\) has a positive noise bias. Fitting the two directly measured quadratures can be preferable to fitting the length.

Explore two mechanisms

The graph holds the homogeneous \(T_2\) at 2 ms. It lets you set signed cyclic detuning and shot-to-shot cyclic frequency spread. Compare both quadrature populations with the upper contrast envelope. First reverse the sign of the detuning, then increase the spread without changing the mean. Which effect interchanges peaks of one quadrature and which damps both?

Tutorial

What is the fringe spacing in a scan of cyclic detuning at fixed delay of 0.80 ms?

Work through the solution

One full phase cycle needs \(\delta f\,\tau=1\). The spacing is

\[1/0.00080=1250\,\mathrm{Hz}.\]

The angular-frequency spacing is \(2\pi\) times larger.

A fixed delay gives

\[P_0=P_{\pi/2}=0.5.\]

Does that show a phase of 45 degrees?

Work through the solution

Both centred quadratures are zero, so the contrast is unresolved and the angle is undefined. A phase of 45 degrees with finite contrast gives equal, nonzero centred quadratures.

Explain how a refocusing pulse halfway through the evolution helps identify quasistatic detuning noise.

Work through the solution

The pulse exchanges the phase-accumulating states, reversing phase winding for a detuning that stays constant through both halves. Random variations during the interval need not cancel. Recovering contrast in the refocused sequence supports a slowly varying contribution to the original envelope.

Compare a continuous drive in the transition chapter with the role of the second pulse here.

Ensembles, diffusion and finite data

Contrast conservation along a microscopic orbit with apparent relaxation after coarse sampling. Test a diffusion law and infer an unknown thermal state from a sequence of noisy observations.

  1. Liouville flow and what an ensemble can remember
  2. Time-dependent diffusion
  3. What a periodic grid does to a decaying Fourier mode
  4. Splitting a stiff relaxation from a slowly varying drive
  5. Learning a drifting temperature from a sequence of readings
  6. Predicting a new measurement when the fitted parameters are correlated
  7. Symplectic transformations, Poisson brackets and the geometry of measurements
  8. Action, angle and the slowing clock at a separatrix
  9. Action density, stress waves and the boundary that reflects them

Liouville flow and what an ensemble can remember

A cloud of identical noninteracting beads is released with slightly different initial positions and momenta. Its position distribution widens. Does the system occupy more phase space, or has its uncertainty merely changed shape?

Follow a small phase-space element

For one canonical degree of freedom the velocity of a point \((q,p)\) is \((\partial_pH,-\partial_qH)\). A short-time map takes \(\boldsymbol z\) to \(\boldsymbol z+\boldsymbol v(\boldsymbol z,t)\,dt\). Its Jacobian matrix is \(I+(\partial\boldsymbol v/\partial\boldsymbol z)dt\); expanding the determinant gives \(1+(\nabla_z\cdot\boldsymbol v)dt+O(dt^2)\). Hamilton's equations make the divergence zero because the two mixed second derivatives of a smooth Hamiltonian cancel. Each additional canonical pair contributes a similar cancellation. A time-dependent Hamiltonian may change energy but still preserve the instantaneous phase-space volume along the flow.

Conservation of the number of ensemble members in a moving phase-space box also gives the continuity equation \(\partial_t f+\nabla_z\cdot(f\boldsymbol v)=0\). The vanishing divergence leaves \(df/dt=0\) on each trajectory. A stationary mechanical system can admit \(f=F(H)\) as a stationary distribution because trajectories stay on energy surfaces. Such stationarity alone does not imply that one trajectory explores an entire energy surface. For example, further integrals of motion restrict regular multidimensional trajectories.

Propagate a cloud released into free flight

For mass \(m\), the exact map is \(p=p_0,\ q=q_0+tp_0/m\). Its determinant is one regardless of time. An initially uncorrelated cloud with variances \(s_q^2,s_p^2\) has evolved covariance \(C_{qp}=ts_p^2/m\). The new position variance is \(s_q^2+(ts_p/m)^2\), while the momentum variance stays fixed. Compute the determinant of this covariance matrix:

\[\sigma_q^2\sigma_p^2-C_{qp}^2=s_q^2s_p^2 .\]

For a Gaussian the ellipse at a fixed multiple of the covariance radius thus retains its area while it shears. With \(m=1\,\mathrm{kg}\), \(s_q=1\,\mathrm m\), \(s_p=0.5\,\mathrm{kg\,m/s}\), and \(t=4\,\mathrm s\), the observed position standard deviation is \(\sqrt5=2.236\,\mathrm m\). The momentum standard deviation remains 0.5 and the covariance becomes \(1.0\,\mathrm{kg\,m^2/s}\). Their uncorrected width product is 1.118 in action units. The square root of the covariance determinant is still 0.5. Multiplication of measured marginal widths alone falsely suggests an area increase.

Compare reversible shear and real drag

Now apply a linear drag \(\dot p=-\gamma p\) to each bead with constant \(\gamma>0\). Its phase-space divergence is \(-\gamma\), hence the map determinant after time \(t\) is \(e^{-\gamma t}\). Direct integration gives

\[p=e^{-\gamma t}p_0,\ q=q_0+(1-e^{-\gamma t})p_0/(m\gamma).\]

The cloud now genuinely loses area in the reduced bead description. A larger Hamiltonian model of bead plus environment can remain volume preserving. Choose a drag rate in the graph and compare the original, freely sheared and damped ellipses for the same observation time. Check there is a smooth zero-drag limit rather than substituting zero into a quotient.

Tutorial on distinguishing a shear from dissipation

A harmonic oscillator maps its scaled quadratures by a rotation. Show why an initially anisotropic cloud can periodically sharpen in position without phase-space cooling.

Work through the solution

Write its covariance as \(R\Sigma_0R^T\). Since \(\det R=1\), its determinant is unchanged. A rotation of one quarter turn exchanges the original widths, so position can sharpen when the original momentum width in scaled units was smaller. Energy extraction is unnecessary.

At \(t=3\,\mathrm s\) the measured ellipse area is 55 percent of the initial area in the linear-drag model. Infer \(\gamma\). Which independent observable checks the inference?

Work through the solution
\[\gamma=-\ln(0.55)/3=0.199\,\mathrm{s}^{-1}.\]

The ratio of final to initial momentum standard deviations should also be 0.55 for drag without random forcing. Added environmental fluctuations would modify that prediction.

Further reading · Cambridge classical dynamics, Hamiltonian flow and Liouville's theorem.

Time-dependent diffusion

Derive the diffusion time-step restriction from two independent arguments and compare explicit and implicit decay of spatial modes.

From first principles

Derive the explicit heat step and its grid-dependent time scale

Take the heat equation \(T_t=\alpha T_{xx}\) with constant positive diffusivity on a uniform one-dimensional grid. Fourier conduction through each side of a cell produces a temperature update proportional to the difference of the two neighbour gradients. With forward Euler timing, collect those fluxes to obtain

\[T_i^{n+1}=T_i^n+r(T_{i-1}^n-2T_i^n+T_{i+1}^n),\]
\[r=\alpha\Delta t/h^2 .\]

When \(0\le r\le1/2\) the new temperature is a convex average of three old ones, preserving bounds on a source-free grid. To check whether a higher step could still be stable for all periodic grid disturbances, substitute \(T_j^n=g^n e^{ij\theta}\), where \(j\) is the node index. The amplification simplifies to

\[g=1+r(e^{-i\theta}-2+e^{i\theta})=1-4r\sin^2(\theta/2).\]

The alternating mode at \(\theta=\pi\) gives \(g=1-4r\), so \(|g|\le1\) again requires \(r\le1/2\). Halving spatial spacing therefore quarters the largest explicit time step for this discretization. Implicit stepping changes this restriction but still has to resolve any transient relevant to the measurement.

Derivation and applications

Can an energy-stable heat step create an alternating transient?

A diffusion mode should decay rather than oscillate. To distinguish decay of a norm from preservation of sign, examine the finite-element or finite-volume semidiscrete system \(M\dot u+Ku=0\), with symmetric positive definite mass matrix \(M\) and thermal stiffness \(K\) positive semidefinite. An eigenvector satisfying \(Kv=\lambda Mv\) has scalar amplitude \(y(t)\) obeying \(y'=-\lambda y\). A generalized \(\theta\) step applied to this mode gives

\[[1+\theta z]y^{n+1}=[1-(1-\theta)z]y^n,\]
\[z=\Delta t\,\lambda .\]

For Crank–Nicolson take \(\theta=1/2\). The factor \(G=(1-z/2)/(1+z/2)\) has \(|G|\le1\) for all \(z\ge0\) but changes sign when \(z>2\). An initial grid-scale component can therefore alternate in time. To test a remedy, replace the first full step by two half backward-Euler steps. Their combined factor is

\[G_{\rm start}=(1+z/2)^{-2}.\]

Thereafter return to the second-order Crank–Nicolson update. After \(n\) further full steps the mode amplitudes, with and without the initial damping, are

\[y_{\rm damped}=G_{\rm start}G^ny^0,\]
\[y_{\rm plain}=G^{n+1}y^0 .\]

For small \(z\), both startup strategies agree through first order, while for large \(z\) the two half steps strongly suppress the unresolved mode. This argument explains a startup treatment for nonsmooth initial data; sign preservation of every physical grid value is a stronger matrix property than sign preservation of one mode.

Worked example

Check damping of a near-grid-scale eigenmode

Take \(\lambda=2000\) s⁻¹ and \(\Delta t=0.0100\) s. Then \(z=20\). A single Crank–Nicolson step leaves \(-9/11=-0.818\) of the amplitude; two backward-Euler half steps leave \(1/121=0.00826\). The exact amplitude factor is

\[e^{-20}=2.06\times10^{-9}.\]

Both discrete results are bounded, but the startup treatment removes almost all of a mode that the time grid cannot resolve.

Second application

Check the cost for a physically slow component

For the same mesh and step, a slow mode with \(\lambda=2.00\) s⁻¹ has \(z=0.0200\). Crank–Nicolson gives \(0.99/1.01=0.980198\), the startup gives \(1/1.01^2=0.980296\) and the exact factor is \(0.980199\). The slow component changes by less than \(10^{-4}\) in this comparison. A timestep must still resolve a transient that is itself part of the desired output.

Discretise space and time separately

A heat pulse in a thin insulated rod smooths over time according to \(u_t=D u_{xx}\) for constant positive diffusivity \(D\). Use a uniform grid of spacing \(h\), and initially examine interior points or periodic boundaries so the stencil is unchanged everywhere. Replacing the second derivative by a centred difference gives a system of ordinary differential equations for the nodal temperatures. The time method still has to resolve the fastest rate that this spatial operator can generate.

An explicit Euler step yields \(u_i^{n+1}=r u_{i-1}^n+(1-2r)u_i^n+r u_{i+1}^n\) with \(r=D\Delta t/h^2\). If \(0\leq r\leq1/2\), the update is a convex combination of three temperatures. The maximum cannot rise and the minimum cannot fall in a source-free interior step. Starting with one hot node at 1 and neighbours at zero, \(r=0.4\) gives a centre value 0.2 and neighbours 0.4 after a single step. At \(r=0.6\) the centre would become negative although the continuum heat equation preserves nonnegativity.

Identify the spatial modes that set the limit

Insert \(u_j^n=g^n e^{\mathrm{i}j\theta}\), where \(\mathrm{i}\) is the imaginary unit and \(j\) indexes the grid. The two neighbouring values contribute factors \(e^{\pm\mathrm{i}\theta}\), yielding \(g=1-4r\sin^2(\theta/2)\). Long waves have \(\sin^2(\theta/2)\simeq\theta^2/4\), so their decay approaches the continuum rate as the mesh is refined. The alternating grid mode \(\theta=\pi\) has the most negative amplification and enforces \(r\leq1/2\) for bounded magnitude.

At the limiting value \(r=1/2\) the alternating mode flips sign without losing amplitude. A strict margin damps it. For \(D=10^{-4}\) m²/s and \(h=2\) mm, the maximum explicit step is

\[h^2/(2D)=0.020\,\mathrm{s}.\]

Refining to 1 mm reduces that limit to 0.005 s. The mesh gives a sharper temperature profile yet can cost four times more steps over the same physical interval, besides the increased number of spatial degrees of freedom.

Compare backward Euler and Crank–Nicolson

Writing the semidiscrete system as \(u'=-A_hu\), backward Euler solves \((I+\Delta t A_h)u^{n+1}=u^n\). Crank–Nicolson averages the old and new diffusive fluxes, giving \((I+\Delta t A_h/2)u^{n+1}=(I-\Delta t A_h/2)u^n\). For a Fourier mode put \(s=4r\sin^2(\theta/2)\). Their factors are \(1/(1+s)\) and \((1-s/2)/(1+s/2)\), respectively. Both remain bounded at arbitrarily large \(s\), but Crank–Nicolson may alternate for under-resolved sharp features.

With \(s=20\), backward Euler retains only \(1/21\) per step. Crank–Nicolson yields \(-9/11\), retaining much more of the fast component and reversing its sign. For a smooth low-frequency mode Crank–Nicolson generally gives more accurate temporal decay because it is second order. Decide whether early sharp transients or later smooth behaviour is the relevant physical quantity. To identify spatial and temporal error separately, refine \(\Delta t\) first on a fixed mesh, then refine space with time error kept well below spatial error. Merely halving both at once cannot reveal which term dominated the original discrepancy.

Apply a prescribed heat input without confusing it with temperature

An insulated periodic rod with uniform heating rate \(s\) measured in K/s has an average temperature that must rise by \(s\Delta t\) each step. Sum the centred second differences over the periodic indices: each nodal value appears with coefficients \(1,-2,1\), which cancel. The source alone changes the mean. For \(s=3\) K/s and a step of 0.02 s the numerical average must increase by 0.06 K, independently of the diffusivity and initial profile.

A code can pass this global test while still mishandling short-wave damping, since an alternating error has zero spatial mean. Pair a mean-temperature test with a nonconstant mode-decay test. Use a homogeneous periodic run for isolates of diffusion, and a uniform temperature with prescribed source for the storage term. A failure in one test then identifies a different part of the mathematical balance than a failure in the other.

Prove decay of a discrete thermal energy

Let a closed semidiscrete diffusion model be \(M\dot u+Ku=0\), with \(M\) symmetric positive definite and \(K\) symmetric positive semidefinite. Assume \(K{\bf1}=0\), expressing zero flux for a uniform temperature. Backward Euler satisfies \(M(u^{n+1}-u^n)+\Delta t Ku^{n+1}=0\). Multiplying by the constant vector and using symmetry gives

\[{\bf1}^TMu^{n+1}={\bf1}^TMu^n.\]

Thus the capacity-weighted sum, proportional to stored sensible heat for constant capacities and a fixed reference, is conserved for any step size.

Now multiply by \(u^{n+1}\). The identity \(a^TM(a-b)=[\|a\|_M^2-\|b\|_M^2+\|a-b\|_M^2]/2\) yields the exact balance

\[\tfrac12\|u^n\|_M^2-\tfrac12\|u^{n+1}\|_M^2=\Delta t\,(u^{n+1})^TKu^{n+1}+\tfrac12\|u^{n+1}-u^n\|_M^2 .\]

Both terms are nonnegative. The quadratic quantity therefore decays although total sensible heat is conserved. Subtracting the conserved mean first yields the same decay statement for temperature variation around equilibrium. The first term represents spatial smoothing measured at the new time, and the second reflects the numerical time update. This derivation gives a stability certificate on nonuniform grids without assuming Fourier modes.

Audit two cells with different heat capacities

Choose capacities 1 and 3 J/K, conductance 2 W/K, and initial temperature deviations \((4,0)^T\) K. The conserved sensible heat is 4 J, so the final equilibrium in a closed system must be one kelvin above reference. At \(\Delta t=0.5\) s the matrix \(M+\Delta tK\) has rows \((2,-1)\) and \((-1,4)\), and the right-hand side is \((4,0)^T\). The new temperatures are \((16/7,4/7)^T\). Checking their weighted sum gives \(16/7+3(4/7)=4\), as required. The unweighted average changes, which is physically appropriate for unequal capacities.

The quadratic quantity at the start is \(4^2/2=8\). After the step it is

\[[(16/7)^2+3(4/7)^2]/2=152/49.\]

Its drop is \(240/49\). The conductive contribution is \((0.5)(2)(12/7)^2=144/49\); the time-update contribution is

\[[(-12/7)^2+3(4/7)^2]/2=96/49.\]

Their sum recovers the measured drop exactly. Neither contribution equals a loss of the 4 J of sensible heat. The quadratic measure depends on squared temperatures and has different physical units.

A positive heat supply or a prescribed exterior temperature introduces a boundary or source work term into these identities. Applying the closed-system decay test to an externally heated experiment would therefore diagnose the wrong physical model. Verify which conserved or dissipated quantity is actually implied by the capacity matrix, boundary conditions and source terms before comparing numerical integrators.

The conserved mean suggests another check after many large steps. The steady state must have zero conductance dissipation, which for two connected cells requires equal temperatures. Together with the weighted heat total this fixes both temperatures at one kelvin above reference. A scheme that instead approaches the unweighted initial average of two would be converging to the wrong conserved quantity despite producing a visually smooth, uniform endpoint. The measured quadratic variation about the correct mean tends to zero; the uncentred squared quantity tends to a positive constant because the remaining uniform state still has temperature above the chosen reference.

What happens to a grid-scale temperature ripple?

The alternating spatial mode on a uniform heat grid has discrete Laplacian eigenvalue \(-4/\Delta x^2\). Substitute this mode into each method and compare the amplitude after one step. The plot isolates the shortest resolvable pattern.

What happens to a grid-scale temperature ripple?. Horizontal axis: Diffusion number αΔt/Δx². Vertical axis: Signed amplitude after one time step. Data follow the figure.
Forward Euler reverses the mode above 1/4 and becomes unstable above 1/2. Crank–Nicolson stays bounded for every plotted step but also reverses the mode above 1/2. Smooth initial data can hide this high-frequency diagnostic.
Read values from the plot
Signed amplitude after one time step at selected values of Diffusion number αΔt/Δx².
Diffusion number αΔt/Δx²Forward EulerBackward EulerCrank–Nicolson
0111
0.275−0.10.476190.29032
0.55−1.20.3125−0.047619
0.825−2.30.23256−0.24528
1.1−3.40.18519−0.375

Download all 221 plotted samples (CSV)

Change parameters · What happens to a grid-scale temperature ripple?

Change one input at a time and compare the recalculated curves with the argument above. The browser evaluates this small model locally; the accompanying numerical values state its assumptions and reference checks. Reset restores the reference inputs, and the data can be downloaded as CSV.

What a periodic grid does to a decaying Fourier mode

A periodic diffusion solver predicts the shape of a sampled wave while its amplitude decays too slowly. Fourier analysis separates spatial differentiation error, an unresolved physical mode and errors caused by the time integrator.

Diagonalise the differential operator on the periodic interval

Use a dimensionless coordinate \(0\le x<2\pi\) and solve \(u_t=\kappa u_{xx}\) with periodic values and periodic derivatives. The complex exponentials \(e^{imx}\), with integer m, satisfy both conditions and are eigenfunctions of the second derivative. Put \(u(x,t)=A_m(t)e^{imx}\) and cancel the common exponential. The scalar amplitude equation is

\[A'_m=-\kappa m^2 A_m.\]

Thus every cosine or sine mode decays by \(\exp(-\kappa m^2t)\), with no phase shift, while the m=0 mean is conserved.

On a uniform grid \(x_j=2\pi j/N\), the samples of \(m\) and \(m+\ell N\) agree for every integer \(\ell\). A discrete Fourier transform returns coefficients in one representative band. For the real cosine test with even N we can fold a positive physical mode into \(k=\min(r,N-r)\), \(r=m\bmod N\). A Fourier spectral Laplacian multiplies that coefficient by \(-k^2\). For a resolved mode it differentiates the trigonometric interpolant exactly, up to arithmetic. For unresolved data it differentiates the aliased representative; no operation using only those samples can identify the original m.

Apply the centred difference stencil to a single wave

The standard second difference is \((u_{j+1}-2u_j+u_{j-1})/h^2\), \(h=2\pi/N\). Put the grid wave \(u_j=e^{ikjh}\) into the stencil. Factor out the common phase and simplify with \(e^{i\xi}+e^{-i\xi}=2\cos\xi\). This gives the symbol and its small-h expansion:

\[{e^{ikh}-2+e^{-ikh}\over h^2}=-{4\over h^2}\sin^2(kh/2)=-k^2+{k^4h^2\over12}+O(k^6h^4).\]

The effective squared wavenumber is smaller than \(k^2\) for every nonconstant mode in the resolved band, so this spatial approximation decays too slowly if the time equation is integrated exactly. The error is modest when \(kh\ll1\), but at the Nyquist mode \(kh=\pi\) the ratio is

\[4/\pi^2=0.4053.\]

A stable time integrator cannot repair this spatial attenuation error without additional modeling. The experiment exponentiates both discretizations' symbols exactly, isolating space and sampling here.

Measure separate errors with the same sampled initial data

Choose \(\kappa=0.5,\ m=3,\ N=16\). The true squared wavenumber is 9 and the difference stencil gives 8.006. Starting at unit amplitude, at \(t=0.20\) exact and spectral amplitudes are 0.40657; finite differences give 0.44906. Doubling N to 32 changes the difference result to 0.41716. The absolute amplitude error falls from 0.04249 to 0.01059, a ratio of 4.01 consistent with the second-order expansion. This is a spatial-convergence study because time evolution introduces no truncation error.

Now take \(m=12,\ N=16\). Every sampled cosine equals the low mode \(k=4\) at \(t=0\). At \(t=0.02\), the continuum amplitude for the true physical mode is \(e^{-1.44}=0.237\), whereas the spectral grid predicts

\[e^{-0.16}=0.852.\]

A spectral computation can therefore agree exactly with its trigonometric interpolant and disagree strongly with the evolution of the intended signal. Sampling on a finer grid or obtaining prior bandwidth information resolves that ambiguity. The mean mode is particularly revealing when a nonconstant physical cosine aliases to a constant.

Start at mode 3 and successively double N from 8 to 32. Compute two amplitude-error ratios at the same time. Then use mode 12 on 16 points to observe an alias, and increase N until the Fourier grid represents the intended mode.

Tutorial · resolve a damping rate to a target tolerance

For a mode well inside the grid bandwidth, estimate the number of samples per wavelength needed for a relative error below 1% in the decay rate with centred differences. Test the estimate for \(m=2\). How could the time integrator contaminate a measurement of this spatial error?

Show the resolution estimate

Writing p for samples per wavelength gives

\[kh=2\pi/p.\]

The relative rate error is approximately \((kh)^2/12\). Requiring at most 0.01 gives \(p\gtrsim18.14\); try 19 samples per wavelength, or \(N=38\) for \(m=2\). The exact ratio \([\sin(\pi/19)/(\pi/19)]^2\) is about 0.991. A forward-Euler step would replace exponential propagation by \(1-\kappa k_{\rm eff}^2\Delta t\). Its repeated-step error could partly mask the underdamping of the spatial stencil. Compare with the exponential of the discrete symbol before attributing a measured rate to space alone.

Further reading · Lloyd N. Trefethen, Spectral Methods in MATLAB · periodic grids, Fourier differentiation and downloadable programs

Check the discrete eigenvalue with OneSimulation

A spatial sine also diagonalises the five-point Dirichlet Laplacian on a square. Use the same modified wave-number argument in both coordinate directions. Run python poisson-mode.py --mode 2 --cells 8 16 32 and compare the observed nodal error with the discrete eigenvalue prediction in the CSV. This is a steady forced problem whose spatial operator can be checked independently of any time integrator. Download the OneSimulation verification model.

Splitting a stiff relaxation from a slowly varying drive

A sensor tries to follow a changing reference while a fast relaxation damps departures. An explicit method may oscillate wildly even though the underlying transient decays monotonically. Treating the restoring term implicitly can resolve the slow motion using steps longer than the transient time. Whether those steps measure the transient accurately is a different question.

Construct an exact benchmark with two time scales

Let \(s(t)=\sin t\) and choose a relaxation time \(\varepsilon>0\). Consider \(y'=s'(t)+(s(t)-y)/\varepsilon\), with \(y(0)=1\). Set \(e=y-s\). Subtraction of \(s'\) gives \(e'=-e/\varepsilon\), hence the reference solution \(y(t)=\sin t+e^{-t/\varepsilon}\). The slow reference changes over times of order one, while the initial mismatch decays significantly over \(\varepsilon\). We know both pieces exactly and can diagnose errors even when a stable result looks visually smooth.

Explicit Euler applied to a perturbation of the state multiplies that perturbation by \(1-r\), with \(r=h/\varepsilon\). It damps monotonically only for \(0<r\le1\), changes sign while damping for \(1<r<2\), and grows for \(r>2\). These statements compare nearby solutions at equal drive. The full signal also contains the time variation of \(s\). At the boundary \(r=2\) a state perturbation alternates without decaying. Refining the step to follow a slow input alone can therefore give the wrong choice of \(h\).

Solve only the fast part implicitly

Split \(f_{\rm slow}(t)=\cos t\) from \(f_{\rm fast}(t,y)=(\sin t-y)/\varepsilon\). Evaluate the slow part at \(t_n\) and the fast part at \(t_{n+1},y_{n+1}\). This first-order additive implicit-explicit Euler step needs one scalar linear solve:

\[(1+r)y_{n+1}=y_n+h\cos t_n+r\sin t_{n+1}.\]

The state perturbation now multiplies by \(1/(1+r)\). It is damped at every positive step and tends to zero as \(r\) grows. Subtract \(\sin t_{n+1}\) from both sides after solving. The mismatch obeys \(e_{n+1}=[e_n+h\cos t_n-(\sin t_{n+1}-\sin t_n)]/(1+r)\). The bracketed forcing defect is \(O(h^2)\) for smooth input. In the stiff limit at fixed \(h\), the endpoint approaches the current reference. Moving the reference in the fast term to the old time would instead drag it one sample behind in that limit. The choice of what to treat implicitly includes the time at which a fast equilibrium is imposed.

Test early-time accuracy and late-time stability

For \(\varepsilon=0.02\), \(h=0.05\), \(r=2.5\). At the first step the exact value is

\[\sin(0.05)+e^{-2.5}=0.1321.\]

Explicit Euler gives

\[1+0.05(1-50)=-1.45.\]

The implicit-explicit value is

\[[1+0.05+2.5\sin(0.05)]/3.5=0.3357.\]

The latter is stable but visibly overestimates the surviving transient. Its damping factor \(1/3.5=0.286\) differs substantially from \(e^{-2.5}=0.0821\). A question about peak rate or initial settling requires shorter steps even if the late-time reference is recovered.

The experiment holds the final time at one while the number of steps changes. The vertical coordinate is the base-ten logarithm of absolute error, with values below \(10^{-15}\) drawn at that floor. Negative heights therefore correspond to errors less than one. Track the maximum error separately from the final error as the transient dies out. Try an initially unstable explicit run, then double the number of steps. The stiffness criterion depends on the ratio \(h/\varepsilon\), while accuracy on the reference also depends on \(h\) itself.

Tutorial on identifying which component is stiff

Keep \(h=0.04\) and reduce \(\varepsilon\) from 0.04 to 0.004. For each case compare exact, explicit and implicit amplification of a state perturbation. What quantity would force a reduction of \(h\) even with the implicit-explicit method?

Work through the solution

At \(r=1\) the three factors are \(e^{-1}=0.368\), zero and \(1/2\). At \(r=10\) they are \(4.54\times10^{-5}\), \(-9\) and \(1/11=0.0909\). For a measurement of the initial decay rate the implicit discretisation substantially misrepresents both exact factors. Bounding error during that transient requires smaller steps relative to \(\varepsilon\), even though its numerical amplification is stable.

Further reading · Ascher, Ruuth and Wetton, implicit-explicit time discretisations.

Learning a drifting temperature from a sequence of readings

Derive the scalar Kalman update by completing the square and see how process uncertainty controls memory of the past.

Propagate a distribution through time

A drifting offset follows \(x_k=x_{k-1}+w_k\). A thermometer reports \(z_k=x_k+v_k\). Assume independent, zero-mean Gaussian process increments of variance \(Q\) and sensor noise of variance \(R\), independent at each time and of the initial state. Before the next reading, the mean stays at \(m^-=m_{k-1}\) and the variance adds, \(P^-=P_{k-1}+Q\).

The negative log posterior, up to constants, is \((x-m^-)^2/(2P^-)+(z_k-x)^2/(2R)\). Collect the coefficient of \(x^2\) and its linear term. The result can be written in two equivalent forms:

\[P_k=(1/P^-+1/R)^{-1},\]
\[m_k=m^-+K(z_k-m^-),\]
\[K=P^-/(P^-+R).\]

Thus the fraction of the innovation used is a model prediction. When sensors are noisy the gain falls. When the model permits rapid drift, uncertainty grows between readings, giving the new measurement a larger role. These are variances, so a stated standard deviation must be squared first.

A reading with units and a repeated reading

A prior says \(20.0\pm2.0\) °C (one standard deviation), with negligible intervening drift. A sensor of standard deviation 1 °C reads 23 °C. The gain is \(4/(4+1)=0.8\), giving \(22.4\) °C and variance \(0.8\) °C². A second independent reading of 23 °C gives gain \(0.8/1.8\) and mean \(22.6667\) °C. Treating a duplicate record as independent would falsely claim the same information gain.

In a long random walk with \(Q=0.25\) and \(R=1\) in squared units, a steady posterior variance satisfies

\[P=(P+Q)R/(P+Q+R).\]

Rearrangement gives \(P^2+QP-QR=0\), so the physically positive root is about 0.3904. New uncertainty replenishes the information squeezed out by measurement.

Follow a change in the underlying temperature

For a reproducible illustration, a fixed synthetic thermometer trace contains a smooth periodic disturbance and a step in the hidden temperature. It is deliberately held fixed while the filter's assumed \(Q\) and \(R\) change. Compare the lag just after the step with the wiggle once the temperature settles.

Tutorial on noisy data over time

If \(Q=0\), show how \(n\) independent readings with the same variance affect precision.

Worked solution

Each update adds \(1/R\) to precision \(1/P\). Induction gives

\[1/P_n=1/P_0+n/R.\]

This is precisely the precision of a batch Gaussian update.

What pattern in the innovations would call the random-walk assumptions into question?

Worked solution

A long run of positive innovations after a systematic ramp suggests bias in the prediction. Serial correlation suggests missing dynamics or correlated observation errors. Check against predicted innovation variance \(P^-+R\) and examine signs and lags as well as their sizes.

Read the university treatment

Extend the scalar precision update to several state variables and identify the matrix made invertible by a positive observation variance. Stephen Boyd · Stanford EE363, estimation and the Kalman filter

Predicting a new measurement when the fitted parameters are correlated

Propagate the full posterior covariance to a quantity of interest, distinguish latent and measured uncertainty and select the observation that reduces the uncertainty of the actual prediction.

One model supplies many possible targets

For parameters \(\theta\) with posterior mean \(m\) and covariance \(C\), a linear target \(s=h^T\theta\) has mean \(h^Tm\). Subtract the mean and expand the quadratic product to obtain

\[\operatorname{Var}(s)=h^TCh.\]

An independent sensor with variance \(R\) changes the variance of a future measured value to \(h^TCh+R\). Repeated fits of noisy datasets and repeated physical measurements are distinct sources of variation.

A candidate new observation \(z=a^T\theta+\epsilon\) with variance \(R_a\) has covariance \(h^TCa\) with the target. For a Gaussian posterior the conditional covariance update is \(C_+=C-Caa^TC/(a^TCa+R_a)\), found either by completing the square or projecting out the optimal multiple of the innovation. The target variance decreases by

\[\Delta\operatorname{Var}(s)=\frac{(h^TCa)^2}{a^TCa+R_a}.\]
Background · Posterior predictive
\[p(y_*|y)=\int p(y_*|m)p(m|y)\,dm\]

A distribution over parameters induces uncertainty in a new observation. Measurement noise and uncertainty of the prediction mean are distinct contributions.

A precise sum and an uncertain difference

Let \(C\) have diagonal entries 1 and correlation \(-0.9\). A target \(h=(1,1)\) has variance \(2-1.8=0.2\). The difference \(h=(1,-1)\) has variance 3.8. Ignoring correlations would predict 2 for both. With sensor variance 0.25, a newly measured sum has variance 0.45 although the latent sum variance remains 0.2.

For the target sum, measuring the first coordinate with variance 0.25 reduces variance by \((1-0.9)^2/(1+0.25)=0.008\). Measuring the sum itself at the same variance reduces it by \(0.2^2/(0.2+0.25)=0.0889\). These two sensors have differently normalised sensitivity vectors. Their stated noise levels refer to their own output units and must be calibrated before a cost comparison.

Choose the measurement direction

For a fairer geometric comparison, restrict both measurement and prediction directions to unit length. Fix the target along the normalised sum. Sweep candidate observation angles and read the remaining prediction variance. Change the parameter correlation: when does a coordinate sensor improve the target appreciably?

Tutorial on prediction and parameter recovery

If \(h^TCa=0\), can a noise-free measurement of \(a^T\theta\) improve the linear prediction under these Gaussian assumptions?

Worked solution

The covariance reduction is exactly zero. The measurement may determine another direction precisely while carrying no linear information about the target.

The posterior on \(\theta\) is strongly non-Gaussian. Which conclusions still hold exactly?

Worked solution

Mean and variance of a fixed linear prediction still follow from its first two moments, and independent sensor variance still adds. The Gaussian conditional update and an interval based only on two standard deviations need additional assumptions.

Read the university treatment

Compare the projection of a vector measurement with the covariance of a scalar target. Check the direction of each matrix product. Stephen Boyd · Stanford EE363, estimation

Symplectic transformations, Poisson brackets and the geometry of measurements

Two phase-space plots can enclose the same volume while predicting different responses to an impulse. Derive the stronger condition that makes a change of variables canonical, test it on measured linear maps and use Poisson brackets to propagate observables without solving separately for every coordinate.

Derive the matrix condition from Hamilton's equations

Collect \(n\) canonical positions and momenta into \(z=(q_1,\ldots,q_n,p_1,\ldots,p_n)^T\). Write Hamilton's equations as \(\dot z=J\nabla_z H\), where \(J\) has zero diagonal blocks, identity upper right and minus identity lower left. For a time-independent change \(Z=f(z)\) with Jacobian \(S=\partial Z/\partial z\), the chain rule gives

\[\dot Z=S J S^T\nabla_Z H.\]

To preserve the canonical form for every differentiable Hamiltonian require

\[SJS^T=J.\]

For an invertible square matrix this is equivalent to \(S^TJS=J\). In geometric terms the bilinear antisymmetric form \(\omega(u,v)=u^TJv\) has the same value on any transported pair of tangent vectors.

Taking determinants gives \((\det S)^2=1\), and symplectic maps have positive determinant equal to one. One way to see the sign is to take the top exterior power of the preserved two-form: \(\omega^n\) fixes an oriented volume. In one canonical pair the identity \(S^TJS=(\det S)J\) makes determinant one sufficient. In two or more pairs a single volume condition cannot enforce every entry of the matrix condition. For example in ordering \((q_1,q_2,p_1,p_2)\), scaling by diagonal entries \((2,1,1,1/2)\) preserves four-dimensional volume. But \(\{Q_1,P_1\}=2\) and \(\{Q_2,P_2\}=1/2\), so neither conjugate pair has the required bracket. A volume-preserving histogram test alone would miss this failure.

Identify brackets of observables and what they measure

Define \(\{A,B\}=(\nabla A)^T J\nabla B=\sum_i(A_{q_i}B_{p_i}-A_{p_i}B_{q_i})\). For any explicitly time-dependent observable \(A(z,t)\), differentiation along Hamiltonian trajectories gives

\[\dot A=\{A,H\}+\partial_t A.\]

The bracket is antisymmetric and obeys the product rule. Computing it with the chain rule in the new variables proves that canonical transformations preserve brackets, even between nonlinear observables. Conversely the fundamental brackets \(\{Q_i,P_j\}=\delta_{ij}\), \(\{Q_i,Q_j\}=\{P_i,P_j\}=0\) are precisely the entries of \(SJS^T=J\).

For a particle set \(L_z=xp_y-yp_x\). Its Hamiltonian flow as a generator sends \(x\) to \(x-\varepsilon y\), \(y\) to \(y+\varepsilon x\) and rotates momenta by the same infinitesimal angle. The angular momentum components satisfy \(\{L_x,L_y\}=L_z\) with cyclic permutations. Derive one entry directly for \(L_x=yp_z-zp_y\) and \(L_y=zp_x-xp_z\). The \(z,p_z\) pair contributes \(xp_y-yp_x\), with the other terms zero. Rotations about two different axes generally fail to commute. The resulting commutator has the form of a rotation about the third axis even though each underlying infinitesimal motion preserves every canonical bracket.

Jacobi's identity \(\{A,\{B,C\}\}+\{B,\{C,A\}\}+\{C,\{A,B\}\}=0\) implies that the bracket of two time-independent conserved quantities is conserved under the same Hamiltonian. If the Hamiltonian is invariant under rotations about \(x\) and \(y\), its invariance about \(z\) follows from this relation and \(\{L_x,L_y\}=L_z\). Conservation alone need not make two observables commute. A central force can conserve all three angular momentum components, but their mutual brackets remain nonzero. For independent commuting integrals in an integrability argument one must check the involution condition explicitly.

Construct a canonical map for any smooth point transformation

Suppose new coordinates depend only on old coordinates, \(Q=f(q)\). Preserve the canonical one-form exactly,

\[p^T dq=P^T dQ=P^T Df\,dq.\]

Thus \(p=(Df)^TP\) and \(P=(Df)^{-T}p\). Applying the same coordinate matrix to momenta works only for a restricted case such as an orthogonal change of coordinates. An extension of position must be accompanied by a reciprocal rescaling of its conjugate momentum. For \(Q=q^2\) on \(q>0\), for example, \(P=p/(2q)\). The free Hamiltonian becomes \(2QP^2/m\); even a physically free particle can acquire a coordinate-dependent expression for its kinetic energy.

Polar coordinates demonstrate why a momentum variable need not equal a measured tangential component. In the plane \(x=r\cos\varphi,y=r\sin\varphi\). Substituting into \(p_xdx+p_ydy\) gives

\[p_r=\mathbf p\cdot\hat r,\]
\[p_\varphi=r\,\mathbf p\cdot\hat\varphi=L_z.\]

The physical tangential momentum is \(p_\varphi/r\). At radius \(0.40\,{\rm m}\) and transverse momentum \(0.60\,{\rm kg\,m/s}\), the canonical angular momentum is \(0.24\,{\rm kg\,m^2/s}\). Treating the transverse component itself as conjugate to angle would make \(\{\varphi,p_\varphi^{\rm wrong}\}=1/r\). The coordinate singularity at \(r=0\) also prevents these canonical polar variables from covering the entire original phase space with one chart.

Generate shears and test a numerical map

A type-two generating function \(F_2(q,P,t)\) defines \(p=\partial_qF_2\), \(Q=\partial_P F_2\), and \(K=H+\partial_tF_2\) where the transformation can be locally inverted. The differential \(d(F_2-QP)\) equals \(p\,dq-P\,dQ+(K-H)\,dt\). Thus the actions differ only by an endpoint term; taking another exterior derivative at fixed time gives the symplectic form condition. For \(F_2=qP+sP^2/(2m)\), the map is \(p=P,Q=q+sp/m\), free drift over time \(s\). For \(F_2=qP+sV(q)\), the map is \(P=p-sV'(q),Q=q\), a potential kick. Their composition is canonical for any step size even though an alternating drift and kick need not give the exact trajectory.

Take a unit-mass, unit-frequency oscillator with \(h=0.5\). A kick followed by drift gives \(P=p-hq\), \(Q=q+hP=(1-h^2)q+hp\). Its amplification matrix has determinant one and trace \(2-h^2=1.75\), so its eigenvalues form a unit-modulus conjugate pair. The numerical phase per step is \(\arccos(1-h^2/2)=0.50536\), slightly ahead of the exact phase \(0.50000\). Starting at \(q=1,p=0\), the first step gives \(Q=0.75,P=-0.50\), and physical energy becomes \(0.40625\) instead of \(0.5\). Exact bracket preservation does not imply exact conservation of the original energy at every point. If \(h>2\) the same matrix remains symplectic but has a real expanding and contracting eigenvalue; geometric preservation is compatible with numerical instability.

For a numerical implementation with analytic equations unavailable, approximate the Jacobian of a one-step map at selected states by perturbing one canonical component at a time. Compute \(S^TJS-J\) after nondimensionalising coordinates and momenta in conjugate pairs. Repeat with smaller perturbations and at different integration tolerances. A determinant close to one in four dimensions is insufficient. Testing the transported brackets of one position–momentum pair and one cross-pair can reveal a swapped column or misplaced mass factor before a long simulation exhibits visible energy drift.

Track canonical area for a transported experimental ensemble

A narrow group of trajectories lets an experimenter estimate a tangent map without applying a separate perturbation to each coordinate at the same time. Prepare a small covariance ellipse in one canonical pair \(z=(q,p)\), propagate each member through a known linear Hamiltonian device, and compute \(\Sigma_{\rm out}=S\Sigma_{\rm in}S^T\). The ellipse area is proportional to \(\sqrt{\det\Sigma}\), and a symplectic map in one pair preserves that area. Its projections can grow or contract individually: a focusing device can reduce position spread while increasing momentum spread or correlation. Measuring only the two marginal widths ignores their covariance and can falsely suggest area growth.

For a free unit-mass drift of duration two in scaled units,

\[S=\begin{pmatrix}1&2\\0&1\end{pmatrix}.\]

Start with \(\Sigma=\mathrm{diag}(1,1)\). The outgoing covariance has entries \(\Sigma_{qq}=5,\Sigma_{pp}=1,\Sigma_{qp}=2\). The apparent rectangle of marginal standard deviations grows by \(\sqrt5\), yet the determinant remains \(5-4=1\). A plot that suppresses the correlation has discarded exactly the information needed for the area test. Noise in the two channels also contributes to observed covariance, so calibrate sensor variances independently before attributing a small apparent growth to physical dissipation or numerical smoothing.

For two pairs it is possible for a perfectly canonical coupling to exchange projected emittances. Take a uniform rotation of the two positions and the same rotation of their conjugate momenta. It is canonical by construction. If the two incoming pairs have different covariance areas, a ninety-degree rotation swaps them completely; at forty-five degrees each outgoing projected pair contains a mixture. The full four-dimensional symplectic structure remains intact. An experimentally available two-dimensional marginal then tests only part of the dynamics. Counting phase-space points in a volume and measuring cross-pair brackets answer different questions about a strongly coupled system.

The eigenvalues of \(J\Sigma\) are invariant under the linear canonical covariance transport. Indeed \(J S=S^{-T}J\) for symplectic \(S\), so \(J\Sigma_{\rm out}=S^{-T}(J\Sigma_{\rm in})S^T\), a similarity transformation. For a positive covariance these eigenvalues occur as conjugate imaginary pairs, and their positive magnitudes give symplectic covariance scales. This algebraic test can distinguish loss of correlations in a fitted transfer matrix from actual exchange between pairs. It assumes linear propagation of the ensemble. A nonlinear canonical map can stretch a finite ellipse into a curved shape whose covariance determinant changes while its exact enclosed area remains preserved.

Use generating functions to find a moving normal-mode basis

Consider a two-dimensional isotropic oscillator and rotate its coordinate axes by a prescribed time-dependent angle \(\alpha(t)\). Let \(Q=R(\alpha)^Tq\), \(P=R(\alpha)^Tp\) for a proper planar rotation. At any fixed time the map is orthogonal and symplectic. To derive the Hamiltonian in these moving variables, use \(F_2(q,P,t)=q^TR(\alpha)P\). Its time derivative at fixed old \(q\) and new \(P\) is \(-\dot\alpha(Q_xP_y-Q_yP_x)\), with the sign corresponding to axes rotating counterclockwise in the laboratory. The transformed Hamiltonian is therefore

\[K=H_0(Q,P)-\dot\alpha L_z.\]

For constant rotation rate and an isotropic potential the new Hamiltonian has no explicit time dependence. Its value is the combination energy minus rotation rate times angular momentum encountered in the Noether argument. Hamilton's equations now include \(-\dot\alpha\,\hat z\times Q\) in \(\dot Q\) relative to the rotated physical velocity. Thus the transformed canonical momentum \(P\) equals the rotated laboratory momentum rather than \(m\dot Q\). Confusing the two yields incorrect initial conditions for a rotating-frame simulation even if the transformation matrix at the starting instant is the identity.

Take \(m=1.0\,{\rm kg}\), a laboratory point initially at \(q=(0.20,0)\,{\rm m}\) with \(p=(0,0.30)\,{\rm kg\,m/s}\), and axes initially aligned but rotating at \(2.0\,{\rm rad/s}\). The canonical \(P_y\) is \(0.30\,{\rm kg\,m/s}\). The derivative of the rotating-frame coordinate is

\[0.30-2.0(0.20)=-0.10\,{\rm m/s}.\]

It moves in the negative rotating-frame \(y\) direction while its laboratory velocity points positive \(y\). The angular momentum is \(0.060\,{\rm kg\,m^2/s}\), so \(K\) lies \(0.120\,{\rm J}\) below the laboratory Hamiltonian. Both position–momentum transformations preserve brackets; the extra term derives from the moving basis, not a failure of canonical geometry.

An oscillator with two nearly equal natural frequencies provides another reason to track the generating function. If one diagonalises a slowly changing stiffness matrix at each time and keeps only the instantaneous diagonal frequencies, the omitted rotation of the eigenvectors couples the nominal modes through a term of this type. When the eigendirections turn rapidly near a degeneracy, the coupling can be appreciable even if both eigenvalues change little. Measuring the orientation as well as the eigenfrequencies allows the size of this effect to be estimated before fitting amplitude transfer to a spurious dissipation term.

Compare exact phase transport with a dissipative fit

A damped oscillator with \(m\ddot q+c\dot q+kq=0\) has equations \(\dot q=p/m\), \(\dot p=-kq-cp/m\). In the physical \((q,p)\) plane their divergence is \(-c/m\). A small material phase-space area therefore contracts as \(A(t)=A(0)e^{-ct/m}\). No time-independent canonical coordinate change on the same two-dimensional isolated phase space can turn that physical contraction into a Hamiltonian flow preserving area. This conclusion concerns the reduced dissipative description. An expanded system including the degrees of freedom that absorb energy can still be Hamiltonian.

For \(c/m=0.40\,{\rm s^{-1}}\), a pair of independent initial perturbations spanning area one in calibrated coordinates spans only \(0.449\) after two seconds. A numerical step of \(0.10\,{\rm s}\) fitted to that exact map should have determinant \(e^{-0.04}=0.9608\). Forcing its determinant to one during system identification would remove a real dissipative measurement. Conversely a conservative oscillator propagated by forward Euler at matched units and \(h=0.10\) has amplification determinant \(1+h^2=1.01\), corresponding to a spurious area growth. A geometric diagnostic is interpretable only after deciding what physical system and coordinate pair were actually observed.

The pair \(q,v\) differs from canonical \(q,p\) by a constant mass scaling for an ordinary single particle. In one pair with constant mass that scaling does not change a measured same-coordinate before-and-after determinant. For a position-dependent mass, constrained coordinates with a varying metric, or explicit time-dependent changes of measurement scale, volume in raw position–velocity coordinates need not equal canonical volume. For example a free particle expressed in \(Q=q^2\) has canonical momentum \(P=m\dot Q/(4Q)\). A detector estimating phase area in \((Q,\dot Q)\) without the \(Q\)-dependent factor can infer contraction or expansion even when canonical phase area is exactly conserved.

Compute a bracket of mechanical momenta and recover the Lorentz force

For a charge \(e\) in a prescribed vector potential write mechanical momentum \(\boldsymbol\pi=\mathbf p-e\mathbf A(\mathbf q,t)\). The canonical brackets are \(\{q_i,p_j\}=\delta_{ij}\), but the measured mechanical components satisfy

\[\{\pi_i,\pi_j\}=e(\partial_i A_j-\partial_j A_i)=e\epsilon_{ijk}B_k.\]

At nonzero magnetic field they are not simultaneously canonical momenta conjugate to the Cartesian positions. This result is gauge invariant because it involves only the curl of the vector potential. It offers a physical example where replacing canonical by measured momenta in a software interface changes the matrix of fundamental brackets.

With \(H=\pi^2/(2m)+e\phi\), the time derivative is

\[\dot\pi_i=\{\pi_i,H\}+\partial_t\pi_i.\]

The kinetic-energy bracket contributes \((e/m)(\boldsymbol\pi\times\mathbf B)_i\); the scalar potential contributes \(-e\partial_i\phi\); and the explicit derivative supplies \(-e\partial_t A_i\). Their sum is \(e[\mathbf E+(\boldsymbol\pi/m)\times\mathbf B]_i\). Dropping the last term would make time-dependent electric acceleration depend on gauge. In a static uniform \(B_z\), the transverse mechanical momenta rotate although their energy is constant. Canonical bracket structure therefore contains observable information about the force even before integrating a trajectory.

A useful finite-difference test sets \(A_y=B x\) and samples the map from canonical to mechanical variables around one state. The measured bracket \(\{\pi_x,\pi_y\}=eB\) should be constant in space. A code that insists on zero will attribute the entire magnetic response to an erroneous Hamiltonian gradient. A code using mechanical variables legitimately can instead use their noncanonical bracket matrix; its equations must then preserve the correct transformed structure, not the original constant \(J\). Testing the resulting acceleration at zero velocity and at a transverse velocity distinguishes electric and magnetic terms and catches sign errors in the antisymmetric entries.

Derive a reversible drift–kick–drift scheme and its measured phase

For \(H=p^2/(2m)+V(q)\), exact kinetic flow for a duration \(t\) is \(D_t:(q,p)\mapsto(q+tp/m,p)\). Exact potential flow is \(K_t:(q,p)\mapsto(q,p-tV'(q))\). Each is canonical. Compose \(D_{h/2}K_hD_{h/2}\) in chronological order. Applying the same construction with \(-h\) undoes each substep in reverse order, so the full map is time reversible. Symmetry eliminates the even local-error powers in the effective generator, giving a second-order method for smooth \(V\). The individual Hamiltonian pieces need not commute; if they did, the split map would be exact at any step.

For a unit oscillator, carrying out the algebra gives

\[Q=(1-h^2/2)q+h(1-h^2/4)p,\]
\[P=-h q+(1-h^2/2)p.\]

Verify directly that the determinant is one. The trace gives the same step angle \(2\arcsin(h/2)\) as the first-order kick–drift matrix in its stable range, but the new off-diagonal coefficients make the amplitude errors and time reversal different. Starting from \(q=1,p=0\) at \(h=0.50\), one gets \(Q=0.875,P=-0.50\), energy \(0.5078125\). A negative step returns to the initial values apart from roundoff. Passing this one reversal test says nothing about absolute phase accumulated over hundreds of periods.

The map preserves \(q^2+(1-h^2/4)p^2\) exactly for the harmonic test. At \(h=0.5\) the coefficient of \(p^2\) is \(0.9375\), so the preserved ellipses differ slightly from the circles of physical energy. Their reversible oscillation in physical energy is bounded for \(|h|<2\). The per-step phase is about \(0.50536\) at this step, giving a phase gain \(0.536\) radians after one hundred steps. As \(h\) is halved while physical integration time stays fixed, the overall phase error falls approximately by four. Measuring an energy oscillation, a reversal residual and a return time therefore probes three different properties of one apparently simple map.

Compare a symplectic map with the phase of a physical orbit

Change the step of the midpoint update. Distinguish preservation of phase-space structure from agreement of the measured oscillation frequency.

Relate the order of two pulses to their Poisson bracket

A canonical transformation close to identity can be built by applying two brief Hamiltonian operations in different orders. Take one free drift and one potential kick, each of short duration \(s\). A drift then a kick gives

\[q'=q+sp/m,\ p'=p-sV'(q+sp/m).\]

A kick then a drift gives

\[p''=p-sV'(q),\ q''=q+s[p-sV'(q)]/m.\]

To second order their coordinate difference is \(q'-q''=s^2V'(q)/m\); their momentum difference is \(p'-p''=-s^2pV''(q)/m+O(s^3)\). The difference vector equals the Hamiltonian vector generated by \(G=pV'(q)/m=\{V,T\}\), multiplied by \(s^2\). The bracket sets the leading effect of reversing the operation order.

For the harmonic oscillator at \(q=1,p=0,m=k=1\) with \(s=0.10\), a drift then kick gives \((1,-0.10)\); kick then drift gives \((0.99,-0.10)\). The coordinate difference \(0.01\) equals \(s^2V'/m\), and the leading momentum difference is zero for this initial condition. At \(q=0,p=1\), the complementary experiment gives a momentum difference of \(-0.01\) and no coordinate difference. Running both initial states tests the two components of the bracket-generated perturbation. A single apparently correct coordinate update would not detect a sign swap in the other component.

An experimental implementation might use a short force pulse as a kick and free propagation between pulses. The pulse must be short enough that motion during the kick is negligible; otherwise its own kinetic drift enters the comparison at the same order as the desired bracket. Extrapolate the measured difference divided by \(s^2\) to small \(s\), and separately measure acquisition noise, which grows in relative importance under that division. Alternating the pulse order cancels many static calibration shifts but does not magically remove timing offsets correlated with the order. Treat the small bracket signal as a physical difference between two specified protocols.

A transformation preserves all coordinate–momentum brackets but a time integration on the transformed variables produces the wrong laboratory trajectory. Can the bracket check alone identify the error?

Work through the solution

Canonical coordinates guarantee the form of Hamilton's equations. Their actual trajectories still require the correct transformed Hamiltonian, including explicit time dependence of the generating function, consistent initial momenta and a sufficiently accurate integrator. Transform an independently known initial state, compare the initial velocity and acceleration of a measurable coordinate, and follow both descriptions back to the same laboratory frame. A bracket test can establish that a change of variables is admissible without establishing that the correct energy function or physical input was attached to it.

Set compatible units before inspecting a symplectic residual

Suppose position is recorded in millimetres and momentum in kilogram metres per second. Scaling each numerical coordinate to unit variance is convenient for fitting a matrix, but independent scaling of each coordinate and momentum can change the bracket matrix from its textbook form. If \(z'=Dz\) with diagonal \(D\), then \(J'=DJD^T\). For one pair this multiplies its bracket by the product of the position and momentum scale factors. In two pairs these factors can differ. A residual computed against the original \(J\) can flag a harmless unit change or, conversely, mask an error if scales happen to compensate.

Choose a characteristic length \(q_0\), momentum \(p_0\), and common action scale \(q_0p_0\) for each pair if the dimensionless chart is to have a common symplectic scale. Otherwise carry the transformed bracket explicitly through the test. With two oscillators of different physical units, a canonical nondimensionalisation may balance the dynamics better than using the same numerical length scale for both. Report the dimensional transformation along with any determinant or defect norm so another calculation can reconstruct which tangent vectors and measurement units were actually compared.

Tutorial on canonical tests

In two degrees of freedom try \(Q_1=q_1,\ Q_2=q_2,\ P_1=p_1+\alpha q_2,\ P_2=p_2\). Is this map canonical? What is the simplest modification that restores the condition?

Work through the solution

The fundamental mixed momentum bracket is \(\{P_1,P_2\}=\alpha\). Restore zero by also taking \(P_2=p_2+\alpha q_1\), since then the extra term \(\{p_1,\alpha q_1\}=-\alpha\) cancels. The added momentum vector is now the gradient of the scalar \(\alpha q_1q_2\), whose derivative matrix is symmetric. Both candidate maps preserve volume, reinforcing why volume alone cannot decide.

For the unit oscillator kick–drift map find a quadratic quantity it preserves exactly while its physical energy changes.

Work through the solution

Direct substitution gives \(Q^2+P^2-hQP=q^2+p^2-hqp\) for the kick–drift convention above. Multiplying by one half gives a positive modified quadratic invariant when \(|h|<2\). The first step at \(h=0.5\) gives \(0.75^2+(-0.50)^2-0.5(0.75)(-0.50)=1.0\), equal to its initial value. At \(h=2\) the quadratic becomes degenerate and beyond it no longer bounds the motion.

A time-dependent momentum shift is generated by \(F_2=qP-a(t)q\). For a free physical particle find the transformed Hamiltonian and verify constant physical momentum.

Work through the solution

The transformation gives

\[p=P-a,\ Q=q,\]
\[K=(P-a)^2/(2m)-\dot a\,Q.\]

Hamilton's equation gives \(\dot P=+\dot a\), hence \(\dot p=0\). Omitting the explicit \(\partial_tF_2\) term would predict constant \(P\) and a spurious acceleration of the original free particle. This test uses an observable whose physical behaviour is already fixed independently.

Compare generated canonical changes and numerical determinant tests.

David Tong develops canonical transformations and Poisson brackets in Hamiltonian dynamics.

Action, angle and the slowing clock at a separatrix

A phase portrait contains enough information to extract a period by differentiating an area. Use that fact to build a clock for finite-amplitude pendulum motion, determine precisely where slow-parameter invariance fails, and distinguish a librating trajectory from one that makes complete rotations.

Turn a closed phase-space loop into an action variable

For a one-degree-of-freedom Hamiltonian \(H(q,p;\lambda)\) at fixed parameter \(\lambda\), take a connected periodic orbit of energy \(E\). Define its action by \(J(E,\lambda)=(2\pi)^{-1}\oint p\,dq\), oriented along the actual motion. The units are energy times time. A smooth family of nested librating loops has \(2\pi J\) equal to the enclosed canonical phase area. For circulation on a coordinate cylinder, such as an angle increasing through \(2\pi\), the integral still defines an action even though the loop winds around the cylinder. Its area interpretation and sign need a reference branch.

At fixed \(q,\lambda\), differentiating \(H(q,p(E,q))=E\) gives

\[\partial_Ep=1/H_p=1/\dot q.\]

Differentiating the action integral yields \(\partial_E J=T/(2\pi)\), because \(dq/\dot q=dt\) around the orbit. At ordinary turning points \(\dot q=0\), the derivative integrand has an integrable singularity while the two endpoints of the closed loop agree; one can justify the derivative using a local square-root coordinate. Inverting gives

\[\omega(J)=\partial_JE.\]

If \(\theta\) is the angle conjugate to \(J\), the transformed Hamiltonian is \(E(J)\) and \(\dot\theta=\omega(J)\) is constant. This canonical angle generally differs from the geometric angle reported by a camera.

For a unit-mass harmonic oscillator the energy curve \(p^2+\omega_0^2q^2=2E\) is an ellipse. Its area is \(2\pi E/\omega_0\), giving \(J=E/\omega_0\) and a frequency independent of amplitude. One may take \(q=\sqrt{2J/\omega_0}\sin\theta,\ p=\sqrt{2J\omega_0}\cos\theta\), whose bracket is one. The position turns nonuniformly in coordinate space even though the phase angle advances uniformly. Under a slow change in \(\omega_0\), constant \(J\) predicts \(E\propto\omega_0\) and amplitude proportional to \(1/\sqrt{\omega_0}\). Constant action does not mean constant mechanical energy while work is performed by a changing spring.

Integrate the finite-amplitude pendulum

Let \(I=ml^2\), \(\omega_0^2=g/l\), and measure \(q\) from downward vertical. The Hamiltonian \(H=p^2/(2I)+I\omega_0^2(1-\cos q)\) has separatrix energy \(E_s=2I\omega_0^2\). For a libration of turning angle \(q_m<\pi\), define \(k=\sin(q_m/2)=\sqrt{E/E_s}\). The positive momentum branch is \(p=2I\omega_0\sqrt{k^2-\sin^2(q/2)}\). Set \(\sin(q/2)=k\sin u\). Evaluating four quarter-arcs of the loop gives

\[J_{\rm lib}=\frac{8I\omega_0}{\pi}\big[\mathsf E(k)-(1-k^2)\mathsf K(k)\big],\]
\[T_{\rm lib}=\frac{4}{\omega_0}\mathsf K(k).\]

Here \(\mathsf K(k)=\int_0^{\pi/2}(1-k^2\sin^2u)^{-1/2}du\) and \(\mathsf E(k)=\int_0^{\pi/2}\sqrt{1-k^2\sin^2u}\,du\). To verify the first formula after substitution, note that \(k^2\cos^2u=(1-k^2\sin^2u)-(1-k^2)\). The transformed integral of \(k^2\cos^2u/\sqrt{1-k^2\sin^2u}\) splits exactly into the two quoted complete elliptic integrals. The period follows either by \(dq/\dot q\) or by differentiating the action. That independent check is useful when numerical differentiation of noisy action estimates amplifies sampling errors.

At small \(k\),

\[\mathsf K=(\pi/2)(1+k^2/4+\cdots),\]
\[T\approx(2\pi/\omega_0)(1+q_m^2/16+\cdots).\]

At \(q_m=60^\circ\), \(k=1/2\) and \(\mathsf K\simeq1.68575\), giving \(T/T_{\rm small}=1.0732\). A pendulum of length \(1.00\,{\rm m}\) then has period about \(2.153\,{\rm s}\), where the small-angle answer is \(2.006\,{\rm s}\). Timing ten periods rather than one helps resolve the accumulated difference. Measuring the arc amplitude from a projected image requires a geometric correction if the swing plane is tilted relative to the camera.

Approach the saddle from either side

At the upright position \(q=\pi\), the potential is maximal and the equilibrium is a hyperbolic saddle in phase space. Put \(q=\pi+s\) with small \(s\); the energy near the saddle is \(H\simeq E_s+p^2/(2I)-I\omega_0^2s^2/2\). For an orbit at \(E_s-\Delta E\), the time spent in a fixed small neighbourhood includes an integral proportional to \(\int ds/\sqrt{s^2-2\Delta E/(I\omega_0^2)}\). As \(\Delta E\) decreases, this develops a logarithm. Equivalently \(\mathsf K(k)\sim\ln[4/\sqrt{1-k^2}]\) as \(k\to1^-\). The separatrix encloses finite canonical area but its period is infinite. Hence \(\partial_EJ\) diverges although \(J\) itself remains finite.

On the positive rotation branch \(E>E_s\), set \(k_r=\sqrt{E_s/E}<1\). A period is the time for \(q\) to increase through \(2\pi\), so there is only one positive branch of momentum in its action integral. Direct integration gives

\[J_{\rm rot}=(2/\pi)\sqrt{2IE}\,\mathsf E(k_r),\]
\[T_{\rm rot}=4\sqrt{I/(2E)}\,\mathsf K(k_r).\]

At very high energy, the potential is a small modulation and these formulas approach free-rotor values \(\sqrt{2IE}\) and \(2\pi\sqrt{I/(2E)}\). At the separatrix the positive rotation action approaches \(4I\omega_0/\pi\), half the limiting libration action \(8I\omega_0/\pi\). The two actions count different closed paths on a cylinder. The factor two is a topological change in the cycle, not a discontinuous jump in the mechanical momentum at a point.

Test slow conservation against the actual orbit period

To treat slowly varying parameters, define instantaneous action–angle coordinates for each fixed \(\lambda\). The generating function \(W(q,J,\lambda)\) acquires explicit time dependence when \(\lambda=\lambda(t)\), adding \(\dot\lambda\,\partial_\lambda W\) to the transformed Hamiltonian. Its angle dependence produces an oscillating \(\dot J=-\dot\lambda\,\partial_\theta\partial_\lambda W\). On a regular periodic orbit, the integral of an angle derivative over a cycle vanishes. If \(\lambda\) changes little during that cycle and there is no resonant complication, this cancellation explains why the action changes little on average. The requirement uses the actual orbit period at the chosen energy. Near a separatrix it cannot be justified merely by comparing a drive rate to the small-amplitude period.

Consider a parameter ramp lasting \(20\,{\rm s}\) for the one-metre pendulum. Near the bottom this covers about ten periods. For \(1-E/E_s=10^{-6}\), the asymptotic \(\mathsf K\simeq\ln4000=8.29\) gives a period of approximately \(10.6\,{\rm s}\), so the same ramp spans less than two cycles. Even longer ramps fail the scale separation sufficiently close to the saddle. If a varying parameter changes the separatrix area until it meets the trajectory, continued use of a single analytic action branch is especially unreliable. A trajectory can pass into circulation or return to libration depending on its phase and the ramp history.

Compute an action without measuring momentum continuously

Suppose a camera tracks one-dimensional positions over one full cycle, and velocity estimates are noisy. For a known position-dependent potential and calibrated mass, an independent measurement of the turning energy allows phase-area integration without differentiating the camera trace. On a bound orbit \(p_\pm(q)=\pm\sqrt{2m[E-V(q)]}\), so \(J=\pi^{-1}\int_{q_-}^{q_+}\sqrt{2m[E-V(q)]}\,dq\). One needs a potential calibration, both turning positions and a common energy datum. An additive constant in the potential cancels when \(E\) is shifted by the same amount. An unrecognised dissipative force makes the inward and outward energy profiles different and invalidates the assumed single closed energy curve.

Take a particle in the potential \(V(q)=a|q|\), \(a>0\), which can approximate opposed constant restoring forces away from a narrow central smoothing zone. Its turning displacements are \(\pm E/a\). Integrate on the positive half and use symmetry to find

\[J=4\sqrt{2m}E^{3/2}/(3\pi a).\]

Differentiating gives

\[T=2\pi\,dJ/dE=4\sqrt{2mE}/a.\]

The same period follows by constant acceleration: starting at rest at a positive turning point, the fall to the origin takes \(\sqrt{2mE}/a\), one quarter period. Agreement across a nondifferentiable potential cusp is a useful check that the action calculation handles the turning boundaries rather than requiring sinusoidal motion.

For \(m=0.10\,{\rm kg}\), \(a=2.0\,{\rm N}\), and \(E=0.20\,{\rm J}\), the amplitude is \(0.10\,{\rm m}\), action is \(0.00849\,{\rm J\,s}\), and period is \(0.400\,{\rm s}\). If the restoring strength \(a\) doubles slowly at fixed action, \(E\propto a^{2/3}\) increases by \(2^{2/3}=1.59\), while the turning amplitude shrinks by \(2^{-1/3}=0.794\). A harmonic-oscillator action rule \(J=E/\omega\) using a single measured frequency would be incorrect here: the actual \(E/\omega=ET/(2\pi)\) exceeds the action by a factor \(3/2\). The equality found for a harmonic oscillator follows from its linear energy–action relation and need not generalise.

Separate the angle accumulated during a cycle from the action it encloses

In a slowly modulated oscillator an almost constant action can coexist with a measurable phase error. Consider \(\ddot q+\omega(t)^2q=0\) with smooth positive \(\omega\). An approximate oscillation is \(q=A(t)\cos\Phi(t)\). At leading order \(\dot\Phi=\omega\). Cancelling the first-order sine term gives \(2\dot A\omega+A\dot\omega=0\), so \(A\sqrt\omega\) is approximately constant. The amplitude law reproduces conservation of \(E/\omega\) after averaging. The accumulated phase is \(\int\omega(t)\,dt\), which can change by many radians during a slow parameter cycle even if the initial and final frequency and action agree.

For \(\omega(t)=10[1+0.10\sin(2\pi t/T_r)]\,{\rm s^{-1}}\) and \(T_r=20\,{\rm s}\), integration over one full ramp gives \(200\,{\rm rad}\) of leading phase. The largest value of \(|\dot\omega|/\omega^2\) is only a few \(10^{-3}\). To first order the final amplitude returns to its initial value, but the position at the end is set by a phase that is generally not an integer multiple of \(2\pi\). A calculation that expects to return to its initial point after the parameter cycle confuses action invariance with angle closure. A small constant frequency calibration error, integrated over a long ramp, can dominate the final phase error while producing little amplitude error.

A sudden frequency switch gives an instructive opposite limit with exact phase dependence. At fixed \(q,p\), changing \(\omega_1\) instantly to \(\omega_2\) changes the action to \(J_2=p^2/(2m\omega_2)+m\omega_2 q^2/2\). Write the initial state at action \(J_1\) using the harmonic angle. Then

\[J_2/J_1=(\omega_1/\omega_2)\cos^2\theta+(\omega_2/\omega_1)\sin^2\theta.\]

For a frequency doubling, the ratio ranges from one half at a passage through the centre to two at a turning point. For a uniformly sampled ensemble the average ratio is \(1.25\), although the pre-switch and post-switch Hamiltonians are both perfectly integrable.

An experiment can therefore test slowness by preparing the same initial action at different phases and comparing the distribution of final actions. A broad phase-dependent distribution for a rapid switch narrows as the ramp becomes slow on a regular family of tori. Near a separatrix a slow external ramp can still yield a broad distribution because the orbital clock itself stalls. The size of the instantaneous energy, measured without phase and the final Hamiltonian, does not distinguish these mechanisms.

Resolve a separatrix in time without integrating arbitrarily close to the saddle

At exactly \(E_s\), energy conservation gives \(p=\pm2I\omega_0\cos(q/2)\) on \(-\pi<q<\pi\). Choose the increasing branch passing through \(q=0\) at \(t=0\). Separation of variables in \(\dot q=2\omega_0\cos(q/2)\) gives

\[\tan(\pi/4+q/4)=e^{\omega_0t}.\]

Therefore \(q(t)=4\arctan(e^{\omega_0 t})-\pi\),

\[p(t)=2I\omega_0\,{\rm sech}(\omega_0t).\]

This exact orbit approaches the upright saddle exponentially at both infinite endpoints. The two endpoints represent the same physical angle on the cylinder even though they differ by \(2\pi\) on an unwrapped plot.

The separatrix momentum falls to one tenth of its maximum after \(\omega_0 t=\operatorname{arcosh}10\approx2.993\). At \(\omega_0=3.13\,{\rm s^{-1}}\) that takes only \(0.956\,{\rm s}\). Reaching one hundredth takes \(\operatorname{arcosh}100/\omega_0\approx1.69\,{\rm s}\). The logarithmic increase in time per retained significant digit explains why an apparently captured upright state can simply be a trajectory very close to the saddle. Measuring angular velocity as well as angular displacement makes the exponential approach easier to distinguish from a truly stationary upright solution.

The phase area enclosed by both separatrix branches can also be recovered directly. Integrating their difference gives

\[\int_{-\pi}^{\pi}4I\omega_0\cos(q/2)dq=16I\omega_0.\]

Dividing by \(2\pi\) yields the libration limit \(8I\omega_0/\pi\) obtained using elliptic integrals. By contrast a trajectory winding once on the upper branch integrates only the upper momentum, giving half that value. Testing these two integrals on an unwrapped numerical phase trace can reveal a missing lower turning branch or a routine that silently wraps the angle before accumulating \(p\,dq\).

Find a frequency directly from noisy orbital areas

Suppose a calibrated experiment measures the phase areas \(A(E)=\oint p\,dq\) at several energies. With \(J=A/(2\pi)\), the identity \(dA/dE=T\) says that an area-versus-energy slope directly has units of time. Take three close energies \(0.09,0.10,0.11\,{\rm J}\), with measured areas \(0.180,0.202,0.225\,{\rm J\,s}\). A central difference gives \(T\simeq(0.225-0.180)/0.020=2.25\,{\rm s}\) at the centre. If each area has an independent uncertainty \(0.001\,{\rm J\,s}\), the propagated standard uncertainty of that difference is about \(0.071\,{\rm s}\), before accounting for energy uncertainty and curvature of \(A(E)\).

Decreasing the energy spacing would reduce smooth finite-difference bias but amplify the effect of those same area errors. A local fit over several energies can trade variance against the assumption of a smooth slope. Near a separatrix the actual slope varies rapidly, so a wide polynomial fit may smooth away precisely the period increase being sought. Compare with direct return times at selected energies, or fit the logarithmic form justified by the saddle expansion when the orbit is demonstrably in its asymptotic regime. A measured phase area can be highly accurate while an inferred frequency remains poorly constrained because it is a derivative.

A practical area estimate from ordered camera samples uses the polygon formula \(\tfrac12\sum_i(p_i+p_{i+1})(q_{i+1}-q_i)\), including the return to the initial point with a consistent sign. Very long time sampling can overrepresent the slow turn neighbourhood but need not corrupt a properly oriented geometric line integral. It can make a uniform-clock finite difference of velocity near a turnaround noisy, however. If a dataset includes several cycles with dissipation, do not simply close the final state back to the beginning of the first cycle. Find individual return events, estimate the action per cycle and test whether its change is consistent with measured losses.

Construct the canonical angle on two sides of a turning point

For a bound one-dimensional potential take a reference crossing at the lower turning point and choose the increasing-\(q\) branch. A Hamilton–Jacobi generating integral is

\[W(q,J)=\int_{q_-}^{q}p(q',E(J))\,dq'.\]

Its angle is \(\theta=\partial_JW=(dE/dJ)\int_{q_-}^{q}dq'/\dot q'=\omega t_{\rm flight}\) on that branch. At the upper turning point \(\theta=\pi\) for a time-reversal-invariant kinetic-plus-potential Hamiltonian. On the return branch the same coordinate \(q\) must be assigned the complementary angle \(2\pi-\theta_{\rm outgoing}(q)\), because its momentum has opposite sign. The coordinate alone is insufficient to reconstruct a unique phase.

For a harmonic oscillator beginning at its leftmost position a quarter-amplitude point is crossed at two different times. In coordinates \(q=-A\cos\theta\) take \(q=-A/2\). The increasing branch gives

\[\theta=\pi/3;\]

the returning branch gives \(5\pi/3\). Their velocities have opposite signs. Using the principal arccosine for every time sample forces both branches onto the same interval and makes an apparently discontinuous phase that never completes a cycle. Measuring the sign of velocity or interpolating successive turning events restores the appropriate branch. Near a saddle, tiny velocities make this branch identification particularly sensitive to camera noise.

Once a reliable angle is available, the phase deviation from the uniform prediction \(\theta(t_0)+\omega(t-t_0)\) becomes a useful diagnostic. A static potential with a wrongly calibrated shape can cause a phase error periodic in position even when its return time is fitted correctly. Dissipation usually changes the action as well, while a constant clock error causes a steadily accumulating phase drift. Compare the residual over several cycles at different amplitudes and plot it against reconstructed angle as well as laboratory time. These alternate plots test different physical explanations of the same timing mismatch.

Measure the area of a closed orbit

Inspect how deformation of a potential changes an energy contour. Compute its action before using it to infer an adiabatic frequency.

Separate a true separatrix crossing from a change of angle convention

Imagine slowly reducing the pendulum's gravitational strength while a bob initially librates. The separatrix action \(J_s=8I\omega_0/\pi\) decreases with \(\omega_0\). Away from the crossing the orbit approximately maintains its own action, so its energy as a fraction of the instantaneous barrier rises. When the shrinking separatrix action reaches that of the orbit, no closed librating torus of that action remains. The system can enter one of the two circulation branches. Its action convention changes because the relevant closed curve on the cylinder now winds rather than traversing two momentum branches. An apparent numerical factor-of-two jump caused by this convention is distinct from the actual dynamics through the slow saddle neighbourhood.

For an initial libration action equal to \(0.40\) of the original separatrix action at fixed \(I\), a parameter protocol reducing \(\omega_0\) to half its original value leaves \(J/J_s\) about \(0.80\), assuming adiabatic tracking remains valid. Reducing it to \(0.30\) of the initial value would formally give \(J/J_s=1.33\), impossible for a libration. The naive crossing estimate is \(\omega_0=0.40\omega_{0,\rm initial}\), but the timing and selected rotation direction require integrating the actual trajectory near the saddle; the adiabatic argument loses uniform accuracy there. A local measure of \(p\) and unwrapped \(q\) supplies the physical distinction.

A real parameter protocol must specify how gravity strength changes. A pendulum length ramp changes both \(I=ml^2\) and \(\omega_0=\sqrt{g/l}\), so its separatrix area scales as \(I\omega_0=m\sqrt g\,l^{3/2}\). Reducing length to \(0.64\) of its starting value reduces the separatrix action by \(0.64^{3/2}=0.512\), whereas replacing only \(\omega_0\) in a fixed-\(I\) model would predict the opposite trend. A literal change of length also brings radial kinetic energy and actuator work, as derived for the reelled pendulum. Specify the physical control path in parameter space before applying a numerical action law.

An unwrapped angle increases by \(2\pi\) over a recorded interval but the phase portrait seems to contain a bounded loop. Can both observations be trusted simultaneously?

Work through the solution

A true circulation winds around the cylindrical phase space, whereas a libration has zero net unwrapped displacement after a full return. A plot that wraps angles into a fixed interval and draws a line across its boundary can display an artificial closing segment. Conversely, measurement noise near \(\pm\pi\) can make a naive unwrapping code insert a spurious \(2\pi\) jump. Inspect signed momentum and the time-resolved crossing of the angle boundary, then reconstruct the loop in adjacent copies of the coordinate interval. Explicitly identifying the cycle on which the action was integrated resolves the apparent contradiction.

Infer work during an adiabatic change from a phase average

Differentiate the action integral at fixed energy with respect to the external parameter \(\lambda\). The energy relation gives \(\partial_\lambda p|_{E,q}=-H_\lambda/H_p\), so \(J_\lambda|_E=-(2\pi)^{-1}\oint H_\lambda\,dt\). Combine this with \(J_E=T/(2\pi)\) and differentiate at fixed \(J\). The result is

\[\partial_\lambda E|_J=\langle\partial_\lambda H\rangle_{\rm time}.\]

A slowly changed parameter therefore does net reversible work at the orbit-averaged rate dictated by its conjugate generalised force. The average must weight time, not distance along the plotted phase curve.

For a harmonic spring with stiffness \(k\), \(H_k=q^2/2\) and \(\langle q^2\rangle=A^2/2=E/k\), giving \(\partial_k E|_J=E/(2k)\). Integrating yields \(E\propto\sqrt k\), consistent with \(J=E/\omega\). A \(4\%\) slow stiffness increase raises energy by about \(1.98\%\) exactly under this law. Changing stiffness at a single turning point would instead add \(4\%\) to the energy for that sudden change. The difference quantifies why observing only identical start and end stiffnesses does not identify the work protocol.

Tutorial on interpreting an action experiment

A harmonic oscillator has energy \(0.030\,{\rm J}\) and frequency \(5.0\,{\rm Hz}\). Its stiffness is increased slowly until the frequency doubles. Determine action, final energy and relative amplitude.

Work through the solution

The action is

\[0.030/(2\pi\cdot5.0)=9.55\times10^{-4}\,{\rm J\,s}.\]

Approximately constant action gives a final energy of \(0.060\,{\rm J}\). With fixed mass and \(E=m\omega^2A^2/2\), the final amplitude is \(1/\sqrt2\) times its initial value. A sudden change performed at a particular phase would in general give a different final action.

A simulation estimates pendulum periods by differentiating sampled action values on a coarse uniform energy grid. Why is the last estimated period below the separatrix likely to be inaccurate even if the individual areas are well converged?

Work through the solution

A finite difference averages \(dJ/dE=T/(2\pi)\) over a finite energy interval. The derivative rises logarithmically near the saddle, so the average can underestimate its endpoint value markedly. Refine adaptively in the distance to \(E_s\), use the elliptic quadrature or measure return times directly. The numerical integrator must also locate the long dwell near the unstable equilibrium without stepping across it artificially.

Two trajectories have energy \(E_s+\delta\), one rotating clockwise and one anticlockwise. Can energy and the positive magnitude of rotation action distinguish them?

Work through the solution

Both have the same speed at each angle and the same positive action magnitude and period. The sign of momentum or a signed orientation of the fundamental rotational cycle distinguishes the branches. Near the separatrix a numerical classifier looking only at energy and unsigned area can lose track of this information. Count the unwrapped angular change and inspect the sign of \(p\) to identify circulation direction.

Measure phase area and compare its change under a parameter ramp.

David Tong develops action–angle variables and adiabatic invariance.

Action density, stress waves and the boundary that reflects them

A chain of coupled masses becomes an elastic field when the wavelength is long compared with the spacing. Derive the field equation and its boundary traction from the same variation, follow energy and stress across a junction, and decide whether a measured pulse is limited by material waves or by numerical dispersion.

Pass from a discrete rod to an action density

Let equal masses of spacing \(a\) move longitudinally by \(u_j(t)\), with nearest-neighbour spring constant \(k_s\) and mass \(m_s\) per site. Their Lagrangian is \(\sum_j[m_s\dot u_j^2/2-k_s(u_{j+1}-u_j)^2/2]\). For variations smooth on the spacing, \((u_{j+1}-u_j)/a\to u_x\) and \(\sum_j a\,f_j\to\int f(x)\,dx\). Hold the line density \(\rho A=m_s/a\) and axial rigidity \(EA=k_s a\) fixed. The continuum Lagrangian density per unit reference length is

\[{\cal L}=\rho A\,u_t^2/2-EA\,u_x^2/2,\]

with \(A\) area, \(\rho\) volume density and \(E\) Young modulus. Both terms have units of joules per metre. This is a slender-rod model with small strain, primarily uniaxial stress and wavelengths long compared with the cross-sectional dimensions.

Vary the field in the action over \([0,L]\times[t_1,t_2]\). Integration of \(\rho A\,u_t\delta u_t\) by parts in time, with fixed endpoint fields, produces \(-\rho A\,u_{tt}\delta u\). Integration of \(-EAu_x\delta u_x\) by parts in space produces \(+\partial_x(EAu_x)\delta u\) and a remaining term \(-[EAu_x\delta u]_0^L\). Thus the interior equation is \(\rho A u_{tt}=\partial_x(EAu_x)\), and the end force conjugate to displacement is axial force \(N=EAu_x\). Adding external work \(F_L(t)\delta u(L)\) at the right face yields

\[N(L)=F_L.\]

A prescribed displacement instead imposes \(\delta u(L)=0\), leaving its reaction as an output. Keeping this boundary term prevents prescribing displacement and independent traction simultaneously at the same end of a second-order rod.

Determine the energy flux and characteristic impedance

Assume time-independent coefficients. Multiply the field equation by \(u_t\) and rearrange to obtain

\[\partial_t[\rho A u_t^2/2+EAu_x^2/2]+\partial_x[-EAu_xu_t]=0.\]

The energy flux is \(-Nu_t\), with positive sign denoting energy moving towards increasing \(x\). The minus sign follows the convention of positive tensile \(N\): positive mechanical power entering through a right face is \(Nu_t\), which is inward with respect to the rod on its left. This identity controls energy transport across both smooth material changes and sharp joints.

For a homogeneous right-moving wave \(u=F(x-ct)\), \(c=\sqrt{E/\rho}\), particle velocity \(v=u_t=-cF'\) and axial force \(N=EAF'=-Zv\), where \(Z=\rho A c=EA/c\). A left-moving wave has \(N=+Zv\). The impedance is force divided by particle velocity and has units \({\rm kg/s}\). If one instead uses stress, impedance is \(\rho c\) per unit area. Doubling the area of the same material keeps wave speed unchanged but doubles the force–velocity impedance. A transit-time measurement and a reflection measurement therefore provide independent material or geometry information.

For a rod with \(E=70\,{\rm GPa}\), \(\rho=2700\,{\rm kg/m^3}\) and \(A=1.0\times10^{-4}\,{\rm m^2}\), \(c\approx5092\,{\rm m/s}\) and \(Z\approx1375\,{\rm kg/s}\). A right-going compressive pulse with particle speed \(0.020\,{\rm m/s}\) carries axial force \(-27.5\,{\rm N}\), compressive stress \(0.275\,{\rm MPa}\), and instantaneous power \(Zv^2=0.550\,{\rm W}\) across a section. A rectangular approximation lasting \(100\,\mu{\rm s}\) carries about \(55\,\mu{\rm J}\) and occupies \(0.509\,{\rm m}\). The pulse speed is kilometres per second; the material particles move only millimetres per second. Treating these as the same velocity would spoil force, impulse and energy estimates.

Match a bonded interface and distinguish amplitude from power

At a perfect massless bond displacement and axial force are continuous. For an incident right-going velocity amplitude \(v_i\) in rod 1, let \(v_r\) be reflected left-going velocity and \(v_t\) transmitted right-going velocity. Velocity continuity gives

\[v_i+v_r=v_t.\]

Force continuity gives

\[-Z_1v_i+Z_1v_r=-Z_2v_t.\]

Thus

\[r_v=\frac{Z_1-Z_2}{Z_1+Z_2},\]
\[t_v=\frac{2Z_1}{Z_1+Z_2},\]
\[{\cal R}=r_v^2,\]
\[{\cal T}=\frac{Z_2}{Z_1}t_v^2=\frac{4Z_1Z_2}{(Z_1+Z_2)^2}.\]

The power fractions add to one for real positive impedances. The reflected force coefficient has opposite sign to the reflected velocity coefficient because the wave direction reverses. At a free end \(Z_2\to0\), reflected velocity equals incident velocity, so end velocity doubles while total force vanishes. At a rigid end \(Z_2\to\infty\), velocity reverses and force doubles. The sign a strain gauge reports can therefore differ from that of a velocity-sensitive optical measurement at the same reflection.

A step from the worked rod into one of the same material with twice the cross-sectional area gives \(Z_2=2Z_1\), \(r_v=-1/3\), \(t_v=2/3\), and power fractions \(1/9\) and \(8/9\). A reduced transmitted velocity amplitude does not imply that most energy is reflected. If the interface includes a concentrated mass \(M_b\), force jumps instead obey \(N_2-N_1=M_b\dot v_b\) with signs determined by forces exerted on that mass from either side. At high frequency the reaction of that mass can mimic a much stiffer termination. Frequency-dependent reflection is then an expected boundary effect, rather than evidence that the bulk modulus varies with frequency.

Connect continuum modes to their lattice predecessor

For a periodic chain the exact discrete equation is

\[m_s\ddot u_j=k_s(u_{j+1}-2u_j+u_{j-1}).\]

Substitute \(u_j=U e^{i(kja-\omega t)}\) to obtain

\[\omega=2\sqrt{k_s/m_s}\,|\sin(ka/2)|.\]

In the first positive Brillouin zone, \(\omega/(ck)=\sin(ka/2)/(ka/2)\) and group velocity \(d\omega/dk=c\cos(ka/2)\), where \(c=a\sqrt{k_s/m_s}\). The continuum rod retains only the leading low-\(ka\) term. A wave with eight sites per wavelength has phase speed about \(0.9745c\) and group speed \(0.9239c\). A narrowband packet's peak can arrive later than the continuum prediction even when a single crest is timed fairly accurately.

A finite-difference code approximating the continuum rod can produce the same spatial dispersion with its mesh spacing in place of a physical lattice spacing. Distinguish them experimentally or numerically by changing the computational mesh while holding the physical structure fixed. Lattice effects persist as the numerical grid is refined; artificial spatial dispersion diminishes. A separate time-step study is needed if a time integrator also disperses the wave. Comparing both peak arrival and phase at two frequencies tests more of the dynamics than fitting a single transit time.

Derive transverse beam waves from curvature energy

A slender beam bending laterally is governed by a different elastic energy from the axial rod. Let \(w(x,t)\) denote small transverse deflection of its neutral axis. Under the Euler–Bernoulli assumption that cross sections remain plane and normal to that axis, the axial strain a distance \(z\) from the neutral axis is approximately \(-z w_{xx}\). Integrating the local elastic energy \(E\epsilon_{xx}^2/2\) across the section gives \(EI_Aw_{xx}^2/2\) per unit length, where \(I_A=\int z^2\,dA\) is a geometrical second moment of area, with units \({\rm m^4}\). It is distinct from a mass moment of inertia. The kinetic contribution uses line density \(\rho A\) as before.

Varying \({\cal L}=\rho A w_t^2/2-EI_Aw_{xx}^2/2\) requires integrating twice by parts in space. With constant coefficients the interior variation gives

\[\rho A w_{tt}+EI_A w_{xxxx}=0.\]

The boundary terms are \(-[EI_Aw_{xx}\delta w_x]+[(EI_Aw_{xx})_x\delta w]\). Thus slope variations pair with bending moments and displacement variations with shear forces, with signs set by the chosen face orientation. A clamped end prescribes both deflection and slope; a free end sets moment and shear to zero. A simply supported end prescribes deflection and zero bending moment. Using only one boundary condition per end, as for the axial rod, leaves the fourth-order beam problem underdetermined.

A sinusoid \(e^{i(kx-\omega t)}\) gives

\[\omega=\sqrt{EI_A/(\rho A)}\,k^2.\]

Phase speed grows proportionally to wavenumber and group speed is twice phase speed in this model. A narrow transverse pulse in a long beam consequently spreads even in a perfectly homogeneous non-dissipative continuum. By contrast the axial rod was nondispersive in its long-wavelength continuum approximation. At high enough frequency the simple bending model omits rotary inertia, shear deformation and eventually three-dimensional elastic behaviour. Extrapolating its unbounded speed to arbitrary \(k\) would use the slender, low-frequency approximation far beyond its derivation.

For a simply supported beam with length \(L\), the sine modes satisfy both end conditions and give

\[\omega_n=(n\pi/L)^2\sqrt{EI_A/(\rho A)}.\]

For a rectangular section of width \(w_b\) and thickness \(d\) in the bending direction, \(I_A=w_bd^3/12\) and \(A=w_bd\). Doubling thickness doubles all the natural angular frequencies at fixed \(L,E,\rho\), whereas doubling width alone leaves the ideal frequencies unchanged. The stiffness increases and so does the inertia. A beam with \(L=0.50\,{\rm m}\), \(d=5.0\,{\rm mm}\) and the earlier aluminium properties has \(\sqrt{EI_A/(\rho A)}\approx7.35\,{\rm m^2/s}\), giving fundamental \(46.2\,{\rm Hz}\). The second bending mode is near four times that frequency, a clear difference from the approximately harmonic axial mode sequence.

Match a force pulse to a support spring and dashpot

A right termination exerts force on the rod through a dashpot with mechanical impedance \(Z_L\). For a real positive dashpot impedance the reflected velocity fraction is \(r=(Z-Z_L)/(Z+Z_L)\). Taking \(Z_L=Z\) gives zero reflection at the termination even though energy leaves a finite rod: the dashpot dissipates the arriving power. With \(Z_L=3Z\) one obtains a reflected velocity of \(-1/2\) of the incident value, a reflected energy fraction one quarter and absorbed power fraction three quarters. A free or rigid end also reflects energy, but it absorbs no net power in the ideal limit. A measured weak reflection alone is therefore not proof of weak damping inside the rod.

For a pure end spring of stiffness \(k_L\) attached to a rigid support, the velocity impedance is \(Z_L=k_L/(i\omega)\) under \(e^{i\omega t}\). It is imaginary, so the reflection coefficient has unit magnitude at every frequency and a frequency-dependent phase. At low frequency the spring impedance is large and the end looks nearly fixed. At high frequency its impedance is small and the end looks nearly free within the lumped approximation. An impulsive signal contains many frequencies and can return with a changed waveform even without any transmitted or dissipated energy. A support combining a resistor-like dashpot and a spring gives both amplitude loss and phase variation.

A measurement with strain gauges at two positions can separate forward and backward waves if their path delays are resolved. In a narrow frequency band the two records are linear combinations of advancing and returning phase factors. If the gauge spacing corresponds to an integer number of half wavelengths, these combinations become linearly dependent and the separation is ill-conditioned. Change the spacing, use a broadband pulse, or combine a velocity measurement with a strain measurement at one station so that the two characteristic directions enter with opposite signs. The relation \(v=(v_++v_-)\), \(N=Z(-v_++v_-)\) then gives a direct local decomposition.

Derive sound propagation from mass and momentum conservation

The displacement-action argument has a fluid analogue. Take an initially uniform fluid of density \(\rho_0\) and pressure \(p_0\), moving little from equilibrium in one spatial dimension. Write small perturbations \(\rho',p',v\). Linearised mass conservation is

\[\partial_t\rho'+\rho_0\partial_x v=0.\]

Momentum balance for a short fluid parcel is \(\rho_0\partial_tv=-\partial_xp'\). If compression over an acoustic cycle is approximately isentropic, \(p'=c_s^2\rho'\) with \(c_s^2=(\partial p/\partial\rho)_s\). Differentiate the first equation in time, eliminate the velocity derivative with momentum balance, and obtain \(\partial_t^2p'=c_s^2\partial_x^2p'\).

The thermodynamic derivative matters because pressure can respond differently when compression is slow enough for heat exchange. For a perfect gas with ratio of specific heats \(\gamma\), isentropic perturbations give

\[c_s^2=\gamma p_0/\rho_0.\]

Taking an isothermal derivative would give \(p_0/\rho_0\) instead. For \(p_0=101\,{\rm kPa}\), \(\rho_0=1.20\,{\rm kg/m^3}\), and \(\gamma=1.40\), the isentropic speed is about \(343\,{\rm m/s}\), while the isothermal calculation gives \(290\,{\rm m/s}\). A measured transit time can discriminate between these constitutive conditions. Wall heat exchange in a very narrow tube can alter which approximation is appropriate over a chosen frequency band.

For a right-moving sound wave \(p'=\rho_0c_s v\), with the pressure positive in compression. This differs in sign from the tensile-positive axial force used for the rod, so match physical force conventions before borrowing formulas across the two examples. The acoustic power per area is \(p'v\). For sinusoidal pressure with rms amplitude \(1.0\,{\rm Pa}\) in the stated gas, the mean intensity is

\[p_{\rm rms}^2/(\rho_0 c_s)=2.43\times10^{-3}\,{\rm W/m^2}.\]

A peak amplitude of \(1.0\,{\rm Pa}\) would yield half this number. Writing rms or peak explicitly prevents a routine factor-of-two error when comparing a microphone measurement with an energy flux.

Determine whether a measured transit reveals a modulus or a geometry

Suppose two axially loaded slender rods have measured wave speeds agreeing within their uncertainties. That alone determines only the ratio \(E/\rho\) under the slender-rod assumptions. Measuring force–velocity impedance \(Z=\rho A c\) and cross section as well gives \(\rho=Z/(Ac)\) and \(E=Zc/A\). With \(Z=1375\,{\rm kg/s}\), \(c=5092\,{\rm m/s}\) and \(A=1.0\times10^{-4}\,{\rm m^2}\), the inversion gives

\[\rho=2700\,{\rm kg/m^3},\]
\[E=70.0\,{\rm GPa}.\]

If area were overestimated by five percent, both inferred quantities would be underestimated by almost five percent while their ratio remained correct.

Now examine a thick elastic solid under a narrow compressional disturbance with wavelengths short compared with its transverse dimensions. Lateral deformation can be constrained by surrounding material. In an isotropic three-dimensional continuum the longitudinal plane-wave modulus is \(\lambda+2\mu_s\), where \(\lambda,\mu_s\) are Lamé coefficients, rather than the uniaxial-stress Young modulus of a slender rod. The shear-wave speed satisfies \(c_T^2=\mu_s/\rho\) and longitudinal speed \(c_L^2=(\lambda+2\mu_s)/\rho\). Measuring both, together with density, can recover the two independent elastic moduli. Using only one longitudinal speed to infer Young modulus without specifying the deformation geometry can give a physically incorrect value.

For \(\rho=2500\,{\rm kg/m^3}\), \(c_L=5000\,{\rm m/s}\) and \(c_T=3000\,{\rm m/s}\), these relations give

\[\mu_s=22.5\,{\rm GPa},\]
\[\lambda=17.5\,{\rm GPa}.\]

The implied Young modulus \(E=\mu_s(3\lambda+2\mu_s)/(\lambda+\mu_s)=54.8\,{\rm GPa}\), while \(\rho c_L^2=62.5\,{\rm GPa}\). Both numbers represent material stiffness, but they enter different mechanical boundary conditions. A long thin specimen of the same material should have an axial speed closer to \(\sqrt{E/\rho}=4680\,{\rm m/s}\). Comparing the bulk and rod experiments tests the constitutive and geometrical assumptions behind the measured speed.

Derive orthogonality when a rod changes material along its length

For a rod with positive varying density \(\rho(x)\), area \(A(x)\) and modulus \(E(x)\), a separated free oscillation \(u(x,t)=\phi(x)\cos\omega t\) satisfies

\[-[EA\phi']'=\omega^2\rho A\phi.\]

Suppose two modes \(\phi_n,\phi_m\) satisfy the same homogeneous fixed or free boundary conditions and the correct continuity of displacement and axial force across every perfectly bonded interface. Multiply the first equation by \(\phi_m\), the second by \(\phi_n\), subtract and integrate. Interior terms produced by integration by parts cancel pairwise, including the interface flux terms, and the endpoint terms vanish. Thus

\[(\omega_n^2-\omega_m^2)\int\rho A\phi_n\phi_m\,dx=0.\]

Mode shapes with distinct frequencies are orthogonal under the mass-weighted inner product, not generally under a simple average of displacements measured at uniformly spaced stations. An initial velocity distribution \(v_0(x)\) projects onto mode \(n\) with coefficient \(\int\rho A v_0\phi_n\,dx/\int\rho A\phi_n^2\,dx\). In a rod with a heavy section, the same imposed velocity there stores more energy and carries more modal weight. An experiment interpreting raw camera amplitudes without line-density weighting can misassign energy among modes. Normalising each measured mode shape to unit maximum does not fix the mass weighting needed for energies.

Multiplying one eigenvalue equation by its own shape gives

\[\omega_n^2=\int EA(\phi_n')^2dx/\int\rho A\phi_n^2dx.\]

For an admissible trial function satisfying prescribed displacement conditions, the same quotient bounds the fundamental squared frequency from above when rigid translations are excluded. Consider a uniform fixed–free rod and trial \(\phi=x/L\). The numerator is \(EA/L\) and denominator \(\rho A L/3\), giving \(\omega_{\rm trial}=\sqrt3\,c/L\). The exact fundamental is \(\pi c/(2L)\), so this one-parameter shape overestimates frequency by about \(10.3\%\). It need not satisfy the free-end traction condition itself because that is a natural condition of the variational minimiser; it does need to satisfy the essential fixed-end displacement.

For a free–free rod the constant displacement mode has zero frequency. Using an arbitrary positive trial function without removing its mass-weighted mean can drive a quotient towards zero by adding a large constant. To estimate the first deforming mode impose orthogonality to the rigid translation, \(\int\rho A\phi\,dx=0\). This has an immediate mechanical interpretation: the deformation mode should not translate the centre of mass of an isolated rod. The null mode and its mass-weighted constraint reappear in numerical eigenproblems built from discretised stiffness and mass matrices.

Find where a discrete elastic chain ceases to look continuous

Shorten the wavelength relative to the lattice spacing. Compare the phase and group velocities with those inferred from a continuum action.

Track work and impulse in a one-dimensional pulse experiment

A finite displacement pulse provides a useful warning about integrating strain and velocity records. A right-going strain pulse of one sign can carry net momentum \(\int\rho A v\,dx\). Because \(v=-cu_x\), its integrated material momentum is \(-\rho Ac[u(+\infty)-u(-\infty)]\) at a fixed time. A localised displacement bump that returns to the same displacement on both sides has zero net ordinary material momentum, even though its energy is positive and travels to the right. Its strain and particle-velocity records contain positive and negative parts. A unipolar velocity pulse leaves behind a displacement step, produced by a source that has supplied net impulse.

For a right-moving rectangular velocity pulse of amplitude \(0.020\,{\rm m/s}\), duration \(100\,\mu{\rm s}\) in the worked rod, the local displacement jump measured in time is \(2.0\,\mu{\rm m}\). Its impulse magnitude across a section is \(Z v\Delta t=2.75\times10^{-3}\,{\rm N\,s}\), while its transmitted energy is

\[Zv^2\Delta t=55.0\,\mu{\rm J}.\]

A second equal pulse of opposite velocity sign launched later cancels the net displacement and material momentum but doubles the transmitted energy. Thus integrating a signed velocity signal and integrating its square distinguish different properties of the same experimental record.

A displacement sensor has a small linear drift during a burst. Which inferred observables are particularly sensitive?

Work through the solution

Differentiating adds a constant offset to particle velocity. Integrating that apparent velocity over a long window produces a growing spurious displacement jump and momentum estimate. Squaring it adds both a cross term with the physical velocity and a positive baseline energy. Measure a pre-pulse baseline, choose an integration interval covering the physical pulse, and test that the result is stable when the window is moderately extended. An independent strain gauge gives another characteristic combination; comparison with \(N=-Zv\) can expose drift or an overlapping reflection.

Can a finite-element rod model with a plausible first eigenfrequency still fail an impulse test?

Work through the solution

The first frequency mostly probes a long-wavelength weighted stiffness-to-mass ratio. A brief pulse contains higher modes and is sensitive to temporal resolution, dispersion, boundary tractions and the way discrete source work enters. Verify modal frequencies at several wavelengths, check the pulse's positive energy and signed impulse separately, and compare the measured incoming and reflected characteristic fluxes. A single standing-wave eigenvalue cannot validate all of those physically independent balances.

Recover a jump condition at an interface with a point mass

For a concentrated mass \(M_b\) joining two rods include \(M_bu_t(x_b)^2/2\) as a separate contribution to the Lagrangian. Its time variation contributes \(-M_bu_{tt}\delta u\) at the joint. The left and right rod boundary terms contribute respectively \(-N_1\delta u\) and \(+N_2\delta u\). Requiring stationarity for an independently varying shared displacement gives exactly \(N_2-N_1=M_bu_{tt}\). This derivation identifies both the sign and the constitutive assumption of a perfectly bonded, nonslipping joint.

For identical rods and a sinusoidal drive at angular frequency \(\omega\), the reflected velocity coefficient becomes \(r=-i\omega M_b/(2Z+i\omega M_b)\) under the stated phasor convention. At \(\omega M_b=2Z\) it reflects half the power and transmits half. The mass itself absorbs no cycle-averaged energy, though it stores kinetic energy during a cycle. For \(Z=100\,{\rm kg/s}\) and \(M_b=0.10\,{\rm kg}\), the equal-power frequency is about \(318\,{\rm Hz}\). A real joint that loses appreciable power at that frequency needs a damping or radiation term in addition to its measured mass.

Tutorial on stress waves

A gauge \(0.80\,{\rm m}\) from a free end records the echo of a sharp disturbance in the worked rod. What echo delay and strain sign should it expect?

Work through the solution

The extra path from gauge to end and back is \(1.60\,{\rm m}\), giving \(1.60/5092=0.314\,{\rm ms}\). A free end has zero net axial force, so the reflected force and strain have opposite signs to the incident ones. The velocity reflection keeps its sign. Finite pulse width and any change of material between gauge and end can obscure that simple result.

A bonded step has measured reflected velocity coefficient \(-0.20\) and no detectable dissipation. Infer its impedance ratio and transmitted energy fraction.

Work through the solution

Rearranging \(r_v=(1-r)/(1+r)\) gives

\[r=Z_2/Z_1=(1-r_v)/(1+r_v)=1.50.\]

The energy reflection is \(0.04\) and transmission \(0.96\). The velocity transmission is \(0.80\), whose square alone is only \(0.64\). Multiplying by the transmitted-to-incident impedance ratio recovers the correct energy fraction.

A rod model with a prescribed displacement at its right end reports nonzero work there, even though the variational boundary term vanished in deriving its equation. Is there a contradiction?

Work through the solution

Vanishing of \(N\delta u\) follows because the allowed virtual displacement at a prescribed boundary is zero. Actual boundary velocity can be nonzero when the prescribed displacement varies in time. The actuator supplies power \(Nu_t\) at the right boundary. Compare the time-integrated input with the change of stored energy plus any losses or outgoing energy rather than identifying an admissible variation with actual displacement.

Compare a finite chain with its long-wavelength continuum.

Fließbach includes string vibrations, beam bending and sound in his continuum mechanics treatment.