Infer the field and the induction from independent windings
Wind a toroidal specimen with a primary winding of \(N_p\) turns and a lightly loaded pickup of \(N_s\) turns. Let \(A\) be the representative iron cross-sectional area, \(\ell\) the mean magnetic path length and \(V_c=A\ell\) the magnetic volume. Neglect a gap and leakage initially. Ampère's law around a path through the core gives
This relation is accurate when the toroid is slender enough that the spread of path radii is small and the pickup current is negligible. In a thick toroid \(H(r)=N_pi_p/(2\pi r)\), so one point on a nominal loop can actually represent a range of local field values.
Faraday's law supplies the second observable. Choose winding polarity so the reported voltage is
Integrating the voltage gives the change in cross-section-averaged magnetic induction. The pickup cannot determine a constant induction offset, because static flux induces no voltage. A closed loop area is insensitive to adding a constant to \(B\) or \(H\), but a dc offset in the voltage integrates into a time-dependent ramp and prevents the reconstructed trajectory from closing. In steady periodic operation one can subtract the voltage mean over a complete period before integration. Applying that correction to a genuinely evolving magnetisation process would remove part of a real flux change.
Multiply the two measured field quantities in the appropriate order. The field work supplied per unit material volume on a small induction change is \(H\,dB\). The source term associated with the magnetising flux is \(i_p v_{p,{\rm induced}}\,dt\). Using \(v_{p,{\rm induced}}\simeq(N_p/N_s)v_s\), its value is
Integrating around a settled cycle gives the magnetic loss
The field can absorb positive work and return some of it later in the same cycle. The area measures the algebraic remainder. Reversing the polarity of a single signal flips the loop orientation. A passively heated specimen must receive positive net energy when signs are defined for power entering the core. Simply taking the absolute value of all instantaneous products would count reversible storage twice and can grossly overestimate the heat.
Work an elliptical loop from time-domain signals
Suppose a nearly sinusoidal field is \(H=H_p\cos\omega t\) and the induction lags it by a positive angle \(\delta\), \(B=B_p\cos(\omega t-\delta)\). Differentiate the latter and multiply by \(H\). Over one cycle \(\cos\omega t\sin\omega t\) averages to zero, and \(\cos^2\omega t\) averages to one half. The resulting mean power density is \(\omega H_pB_p\sin\delta/2\), giving \(\oint H\,dB=\pi H_pB_p\sin\delta\). With zero lag the two signals trace a line and the area vanishes, even if the peak values are large. A saturation-distorted loop need not be elliptical; the original time integral remains valid with synchronised data.
Take \(H_p=120\,{\rm A/m}\), \(B_p=0.200\,{\rm T}\) and \(\delta=12^\circ\). The energy per cycle and volume is \(15.68\,{\rm J/m^3}\). A toroid with \(\ell=0.20\,{\rm m}\), \(A=2.0\times10^{-4}\,{\rm m^2}\) and \(V_c=40\,{\rm cm^3}\) dissipates \(0.627\,{\rm mJ}\) per cycle. At \(f=200\,{\rm Hz}\) its power is \(0.125\,{\rm W}\). With \(N_p=100\), the necessary current peak is \(0.240\,{\rm A}\). With \(N_s=50\), the pickup voltage has peak \(N_sA(2\pi f)B_p=2.51\,{\rm V}\). These last two predictions allow the raw oscilloscope traces to be checked before a calculated loss in watts is trusted.
For sampled periodic data use \(w=\sum_n(H_n+H_{n+1})(B_{n+1}-B_n)/2\), including the segment from the last point back to the first. This trapezoidal line integral computes an oriented polygon area. Plot the starting and ending points before adding the closing segment. Connecting widely separated endpoints by hand hides drift and can generate a fictitious wedge whose area depends on acquisition timing. Repeat at higher sampling rates to see whether corners or switching features carry appreciable extra area. When a periodic excitation has harmonics the time increment must resolve the highest significant harmonic in both measured signals.
Compare a thermal measurement with the magnetic area
Consider first a calorimeter that receives heat only from the core. Let the heat capacity of specimen, holder and sensor be \(C_{\rm eff}\). Let the leakage conductance to an ambient bath be \(G\), and let \(\Delta T=T-T_a\). The thermal balance \(C_{\rm eff}\dot{\Delta T}=P_c-G\Delta T\) predicts a steady offset \(P_c/G\) and an initial heating slope \(P_c/C_{\rm eff}\). A small thermometer lag or poor thermal contact can make the earliest measured slope misleading even though environmental losses are then small. A separate electrical heater placed where the core deposits its heat can calibrate the effective thermal response.
For \(C_{\rm eff}=20\,{\rm J/K}\), \(G=0.015\,{\rm W/K}\), and a \(2.0\,{\rm K}\) rise above ambient, the magnetic loss \(0.125\,{\rm W}\) would give a slope of about \(0.00477\,{\rm K/s}\). The heat already leaking to the bath is \(0.030\,{\rm W}\), too large to discard in a ten-percent comparison. If the winding is inside the same calorimeter, its Ohmic heat must enter the balance as well. With primary resistance \(1.50\,\Omega\) and the computed sinusoidal current, winding heating is
The expected slope of the combined package at the same temperature is now \(0.00693\,{\rm K/s}\). Subtraction of winding heat recovers the core result only when the estimated resistance represents the winding at its operating temperature and frequency.
A thermal estimate drawn from a whole interval is often more robust than a derivative from two adjacent temperature samples. Integrating gives
Divide by the duration for mean power, then remove other measured heat sources. A drifting ambient must be recorded explicitly because the calorimeter stores energy relative to its own absolute temperature. If the core and coil equilibrate slowly with each other, a single fitted heat capacity can depend on the fitting time window. A two-temperature model or a longer dwell then supplies an independent diagnostic.
Separate reversible exchange from hysteretic and induced currents
A single measured loop at finite frequency gives the total energy dissipated by the core at that prescribed waveform and temperature. The loop can include irreversible domain processes, eddy currents and other rate-dependent effects. It does not by itself split these contributions. To probe their different scaling hold the peak induction and waveform shape fixed, then change frequency. Under a restricted low-frequency model the quasi-static hysteresis energy per cycle is approximately constant, while classical thin-lamination eddy-current power scales as \(f^2B_p^2\). Its energy per cycle therefore scales roughly as \(f\). Plotting the measured loss per cycle and volume against \(f\) tests whether such an intercept-plus-slope description fits the chosen range.
Suppose the area is \(12\,{\rm J/m^3}\) at \(100\,{\rm Hz}\) and \(20\,{\rm J/m^3}\) at \(300\,{\rm Hz}\), at the same peak induction. A straight line gives intercept \(8\,{\rm J/m^3}\) and slope \(0.040\,{\rm J\,s/m^3}\). It predicts \(16\,{\rm J/m^3}\) at \(200\,{\rm Hz}\), near the elliptical-loop calculation. Two points always determine a line. A third and fourth frequency, together with uncertainties, are required to test the law. Different losses can share similar frequency scaling over a short interval, and temperature-dependent conductivity can bend a nominally simple curve.
Use the pickup to reject the reversible part of terminal power
Measuring primary terminal voltage and current with a power analyser provides a separate electrical route to loss, but the wanted number can be a small difference between terms. The applied voltage contains winding resistance, induced magnetising voltage, leakage-inductance voltage and possible parasitic contributions. In steady periodic operation the energy stored in a fixed linear leakage inductance returns after each cycle, while winding resistance dissipates energy permanently. The secondary pickup preferentially measures the core-linked flux. Forming \(p_c(t)=(N_p/N_s)i_p(t)v_s(t)\) and averaging over a full cycle estimates core power without directly including the primary's copper voltage drop. It relies on both windings linking the same relevant flux and on negligible power drawn by the pickup.
For the elliptical example the primary magnetising voltage has peak \(5.03\,{\rm V}\) and leads the induction by ninety degrees. Its phase relative to the current is
The core branch's apparent power is \(V_{\rm rms}I_{\rm rms}\approx0.603\,{\rm VA}\); its mean dissipative part is about \(0.125\,{\rm W}\), and the reactive part is about \(0.590\,{\rm var}\). Only the mean part contributes net heating of the magnetic volume. Including the winding voltage adds about \(0.043\,{\rm W}\) of real power to the terminal reading. A simple product of peak current and peak secondary voltage, without the turns ratio, factor one half and phase factor, has no reason to agree with either measured loss.
Consider a nearly ideal core with the same peak signals but a lag of only one degree. Its loss is about \(10.5\,{\rm mW}\), while the much larger reversible power exchange is almost unchanged. A time offset of \(10\,\mu{\rm s}\) at \(200\,{\rm Hz}\) adds \(0.72^\circ\), causing a relative loss error of approximately \(72\%\) for that small lag. Calibrate the relative channel delays using a reference signal through the actual current transducer and voltage chain, including their filters. Adjusting traces on screen until a core loop appears narrow assumes the very loss one is trying to measure. A synchronous measurement over many periods suppresses random noise but does not remove a persistent delay bias.
Test reconstruction on a waveform with a third harmonic
Let \(H(t)=H_1\cos\omega t+H_3\cos3\omega t\) while \(B(t)=B_1\cos(\omega t-\delta_1)+B_3\cos(3\omega t-\delta_3)\). With these definitions \(\delta_n\) is the phase lag of the \(n\)th harmonic in its own sinusoid. Multiplying \(H\) by \(\dot B\) and integrating over an integer number of fundamental periods eliminates products of different harmonics. Each surviving harmonic contributes the number of its own cycles in one fundamental period. The area per fundamental period is therefore \(\pi[H_1B_1\sin\delta_1+3H_3B_3\sin\delta_3]\). This identity tests whether a numerical area calculation tracks the full waveform. It does not assume that a real material is linear; here the two signals are supplied as measured periodic functions.
Use the earlier fundamental values and add \(H_3=20\,{\rm A/m}\), \(B_3=0.030\,{\rm T}\) and \(\delta_3=30^\circ\). The third harmonic contributes \(2.83\,{\rm J/m^3}\) in each fundamental period. This represents an additional \(0.0226\,{\rm W}\) for the chosen specimen and frequency. A fundamental-only sine fit would miss nearly fifteen percent of the resulting total area. An apparent jagged loop can also arise from asynchronous sampling or an offset. Distinguish genuine harmonics by checking that they are phase locked to the drive and persist under a change in sampling rate and analogue bandwidth.
Sweep phase and read the oriented loop
The live experiment reconstructs the \(H,B\) trajectory and compares it with a zero-lag reference. It uses the same peak field and induction for the two curves. At fixed peaks changing frequency leaves an assigned phase lag and therefore the prescribed energy per cycle unchanged, while watts rise with the number of cycles per second. A real core can change its lag and waveform with frequency; the graph separates this independent variable so that the meaning of the two scaled quantities is clear. Add a timing offset and predict the direction of the area error before checking its reported size. Near zero lag even the direction of an apparent loop can be controlled by a small electronic offset.
Two toroids are made of the same nominal material with equal cross sections but different mean path lengths. How should a result reported only as watts be compared?
Work through the solution
Determine actual magnetic volume for each toroid and calculate the energy per unit volume per cycle, \(P/(fV_c)\). Also check that both experienced the same induction waveform, frequency and temperature. Equal primary currents need not give equal field when the path lengths differ; equal primary applied voltages need not give equal core induction if turns, winding voltage drops or area differ. Reproducing the actual \(B(t)\) with feedback on the pickup is a more direct way to match excitation. Report dimensions and peak induction with the result so a reader can reconstruct what material condition was tested.
A saturated sample shows a small loop during a biased excitation that never crosses zero induction. Does the area formula still apply?
Work through the solution
A settled periodic minor loop encloses an area representing the net cyclic energy under exactly that bias and excursion. Adding a static induction offset does not change \(\oint H\,dB\), but the bias can alter the trajectory, differential permeability, and width of the minor loop itself. Do not infer the full major-loop energy from its area. The pickup returns only changes of induction unless an independent dc measurement or a known magnetic preparation supplies the offset. A bias winding may additionally heat the calorimeter, so include its measured power when comparing with thermal loss.
Tutorial on comparing two loss measurements
A data logger reports \(H_p\) and \(B_p\) correctly but adds an uncorrected \(10\,\mu{\rm s}\) delay to the induction channel. Estimate the fractional area error of the elliptical example.
Work through the solution
At \(200\,{\rm Hz}\) the extra apparent lag is
The reported area is multiplied by \(\sin(12.72^\circ)/\sin(12^\circ)\), about \(1.059\). An uncorrected delay of only one hundred-thousandth of a second overstates the core loss by about six percent. For a very low-loss specimen with much smaller physical lag, the same delay produces a far larger relative error.
A thermal run on the combined winding and core reports a slope \(0.0070\,{\rm K/s}\) at \(\Delta T=2.0\,{\rm K}\). Recover the core power and the volume-specific loss area at \(200\,{\rm Hz}\).
Work through the solution
Heat deposition in the package is
Subtract the estimated \(0.0432\,{\rm W}\) of winding heating to obtain \(0.1268\,{\rm W}\) in the core. Dividing by \(200\times4.0\times10^{-5}\) gives \(15.85\,{\rm J/m^3}\) per cycle. Its closeness to \(15.68\,{\rm J/m^3}\) should be evaluated against the uncertainties of heat capacity, thermal conductance, resistance, dimensions and electrical phase alignment.
Vary the magnetic circuit and identify the induction scale used by the specimen.