Fundamentals / Mechanical engineering / Engineering thermodynamics and heat transfer

Thermal diffusion and transient surface cooling

Use diffusion time, Biot number and penetration depth to choose between a uniform-body model and a spatial temperature field.

From first principles

Derive thermal diffusion from stored energy and conductive flux

Let a stationary homogeneous solid have density \(\rho\), specific heat \(c\) and thermal conductivity \(k\). Assume no heat generation and consider one-dimensional temperature variation. A slice of area \(A\) and thickness \(dx\) stores energy at rate \(\rho c A\,dx\,\partial_tT\). The difference between the conductive flux entering and leaving gives

\[\rho c A\,dx\,\partial_tT=A[q''(x)-q''(x+dx)]\quad\Longrightarrow\quad \rho c\,\partial_tT=-\partial_xq'' .\]

Fourier's law \(q''=-k\partial_xT\) closes this balance. For constant properties the diffusion equation and its characteristic time over distance \(L\) follow:

\[\partial_tT=\alpha\,\partial_{xx}T,\]
\[\alpha=\frac{k}{\rho c},\qquad t_{\rm diff}\sim L^2/\alpha .\]

Initial temperatures and boundary heat-flux or temperature conditions are needed to select a specific solution. If conduction inside the solid is sufficiently rapid relative to transfer at its surface, one can integrate the balance using an almost uniform interior temperature. Comparing the internal and external resistance scales yields the Biot number \(hL_c/k\) used for that simplification.

Background · Biot number
\[\mathrm{Bi}=hL_c/k\]

Here h is a surface heat-transfer coefficient and k is conductivity. A small Biot number supports a nearly uniform specimen temperature for the specified boundary condition.

Derivation and applications

Predict how a thermal probe follows a changing fluid temperature

A sensor calibrated by an abrupt temperature step can lag behind a fluid that is itself heating steadily. Take a body of mass \(m\), heat capacity \(c\), exposed area \(A\) and film coefficient \(h\) with negligible internal temperature gradients. This lumped description requires internal conduction to be fast compared with surface heat transfer. Treat properties and \(h\) as constant and neglect self-heating, radiation and lead conduction. Denote the body temperature by \(T\), fluid temperature by \(T_f\), and set \(\tau=mc/(hA)\).

An instantaneous energy balance gives a first-order differential equation. For a linearly increasing fluid temperature \(T_f=T_0+\beta t\), define the lag \(D=T_f-T\):

\[mc\,\dot T=hA(T_f-T),\]
\[\dot D + D/\tau=\beta .\]

Suppose the probe and fluid start in equilibrium at \(T_0\). Multiply the lag equation by \(e^{t/\tau}\) and integrate from zero. The integrating factor converts the left side to a single derivative:

\[e^{t/\tau}D(t)=\beta\int_0^t e^{s/\tau}\,ds=\beta\tau(e^{t/\tau}-1).\]

Subtract the resulting lag from the prescribed fluid history to obtain the reading:

\[T(t)=T_0+\beta[t-\tau(1-e^{-t/\tau})] .\]

For \(t\ll\tau\) the rise begins quadratically, since the initial film temperature difference was zero. For \(t\gg\tau\) the probe warms at the same rate as the fluid but reads low by \(\beta\tau\). Cooling ramps reverse the sign. A measured constant lag is therefore evidence for this model only after the startup transient has decayed.

Worked example

Evaluate the reading during a ramp calibration

A probe has \(mc=0.800\) J/K and \(hA=0.100\) W/K, hence \(\tau=8.00\) s. Start at \(20.0^\circ\)C and heat the fluid by \(0.500\) K/s. At \(t=16.0\) s the fluid is at \(28.0^\circ\)C and the lag is \(4.00(1-e^{-2})=3.46\) K, so the probe reads \(24.5^\circ\)C. Simply subtracting the eventual \(4.00\) K would overcorrect during startup.

Second application

Estimate a time constant without an abrupt temperature step

During a long calibration ramp of \(0.200\) K/s, a second probe remains \(1.20\) K below an independent fluid reference. Its inferred time constant is

\[\tau=1.20/0.200=6.00\,\mathrm{s}.\]

If the fluid is then held fixed, the remaining lag decays exponentially. Waiting \(6.00\ln(1.20/0.100)=14.9\) s brings the error below \(0.100\) K. The hold and the ramp test two different responses using the same fitted parameter.

Try it · Probe ramp

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Allow energy to accumulate in the material

A surface thermocouple responds rapidly to a cold wash, while the interior of a thick part can remain hot. To predict the time needed to cool the centre, steady thermal resistance alone is insufficient. Enclose a differential slice of material. Incoming conductive heat minus outgoing heat plus local generation equals the rate of change of its stored energy. Substituting Fourier’s law in a homogeneous stationary solid gives

\[\rho c_p\frac{\partial T}{\partial t}=k\nabla^2T+\dot q_v,\]
\[\alpha=\frac{k}{\rho c_p}.\]

Thermal diffusivity \(\alpha\) in m²/s compares a material’s ability to spread heat with its ability to store it. A large conductivity does not alone guarantee fast adjustment if volumetric heat capacity is also large. Without heat generation, a length \(L\) gives a characteristic diffusion time \(t_d=L^2/\alpha\). The dimensionless Fourier number \(Fo=\alpha t/L^2\) measures how long diffusion has acted relative to that scale.

Decide whether the interior stays nearly uniform

At a convecting boundary \(-k\partial T/\partial n=h(T_s-T_\infty)\). Comparing the resistance of the interior with a fluid film leads to \(Bi=hL_c/k\), often using \(L_c=V/A_s\) for a lumped model. If this ratio is small, commonly below about 0.1 as a first engineering check, the internal temperature difference is small compared with that across the film. Integrating energy over a uniform body then gives

\[\rho c_p V\,dT/dt=-hA_s(T-T_\infty),\]
\[(T-T_\infty)/(T_0-T_\infty)=e^{-t/\tau},\]

with \(\tau=\rho c_pV/(hA_s)\).

The Biot and Fourier numbers answer different questions. A small Fourier number says a disturbance has penetrated only a short distance compared with \(L\). A small Biot number says the boundary transfers heat slowly enough for internal gradients to remain small. Choose the length for each comparison explicitly, especially for a slab cooled on one side rather than both.

Cooling from a fixed surface temperature reaches farther into the solid as the dimensionless time rises.
Semi-infinite cooling profiles plotted against a fixed reference length L. Increasing time by a factor of ten increases the depth of a given temperature ratio by the square root of ten.

Solve a sudden prescribed-temperature change

Consider initially uniform material occupying \(x>0\) whose surface is suddenly held at \(T_s\), with its far interior still at \(T_i\). Neglect internal generation and use constant properties. The initial and boundary conditions have no geometric length scale. Try the similarity coordinate \(\eta=x/(2\sqrt{\alpha t})\) and set \(\Theta=(T-T_s)/(T_i-T_s)\). Differentiating and substituting into the diffusion equation yields \(\Theta''+2\eta\Theta'=0\), with derivatives in \(\eta\). Integrating once gives

\[\Theta'=C e^{-\eta^2}.\]

The limits \(\Theta(0)=0,\ \Theta(\infty)=1\) give

\[\Theta=\operatorname{erf}(\eta).\]

At \(x=0\) the imposed surface temperature holds exactly. At a fixed depth and very early time \(\eta\) is large, so the temperature tends to its initial value. The distance of any fixed fractional temperature change grows as \(\sqrt{t}\). Quadrupling exposure time doubles that distance, a scaling quite different from a body travelling at a constant speed.

Predict depth and validate the time window

A thick solid initially at 373 K is held at 293 K at its surface. With \(\alpha=1.0\times10^{-5}\) m²/s and \(t=10\) s, \(2\sqrt{\alpha t}=0.020\) m. At depth 10 mm, \(\eta=0.50\) and \(\operatorname{erf}(0.50)=0.5205\), giving \(T=293+80(0.5205)=334.6\) K. At 20 mm, \(\operatorname{erf}(1)=0.8427\) gives 360.4 K. The surface has cooled by 80 K while the deeper sensor has cooled by only 12.6 K.

At 40 s the 20 mm sensor reaches the same fraction previously measured at 10 mm. This prediction assumes the remote boundary has not begun to influence the measurement and that the surface temperature is actually prescribed. A finite slab or a convective wash may require a finite-domain diffusion solution instead. Record surface and interior histories to distinguish uncertain boundary conditions from uncertain diffusivity.

Interpret a penetration depth

If two embedded sensors are at 2 and 6 mm in the same semi-infinite specimen, the deeper sensor reaches the same normalised temperature at nine times the shallow sensor’s time because \(x/\sqrt{\alpha t}\) must match. An observed factor much smaller than nine can indicate a heat leak along a probe or a far boundary that has begun to influence the temperature field.

Resolve a slab with a finite surface film

A prescribed surface temperature and a uniformly cooling lump are two useful limits. A finite slab exchanging heat through a finite film generally satisfies neither. Let \(L\) be half-thickness, \(x=0\) the midplane, and \(T_i\) the initial uniform temperature. Both sides suddenly see fluid at \(T_\infty\) with constant \(h\). Using \(X=x/L,\ Fo=\alpha t/L^2\) and \(\Theta=(T-T_\infty)/(T_i-T_\infty)\), the diffusion equation becomes

\[\Theta_{Fo}=\Theta_{XX},\]

with symmetry \(\Theta_X(0)=0\) and film condition \(-\Theta_X(1)=Bi\,\Theta(1)\), where \(Bi=hL/k\).

Seek a separated mode \(\Theta=\cos(\lambda X)e^{-\lambda^2Fo}\). Its derivative vanishes at the midplane. Imposing the convective surface condition gives

\[\lambda\tan\lambda=Bi.\]

The uniform initial condition fixes modal amplitudes by cosine orthogonality on \(0<X<1\):

\[\Theta=\sum_n A_n\cos(\lambda_n X)e^{-\lambda_n^2Fo},\]
\[A_n=\frac{4\sin\lambda_n}{2\lambda_n+\sin(2\lambda_n)}.\]

For \(Bi\ll1\), the smallest root has \(\lambda_1^2\simeq Bi\), its shape approaches a constant, and \(A_1\simeq1\). The decay becomes \(e^{-Bi\,Fo}\), exactly the lumped time scale because \(Bi\,Fo=h t/(\rho cL)\). For a large film coefficient the first root tends towards \(\pi/2\), corresponding to a prescribed surface temperature. The same boundary-value model thus recovers both limiting behaviours.

Predict when the core and surface meet different targets

A 40 mm thick flat slab with \(k=2.0\,\mathrm{W/(m\,K)}\) and \(\alpha=1.0\times10^{-6}\,\mathrm{m^2/s}\) is cooled on both sides by \(h=50\,\mathrm{W/(m^2K)}\). It starts at 100 °C in fluid at 20 °C. Here \(L=0.020\) m and \(Bi=0.50\). The first root of \(\lambda\tan\lambda=0.5\) is 0.6533 and \(A_1=1.070\). After 600 s, \(Fo=1.50\). The first term gives centre excess ratio \(1.070\exp[-(0.6533)^2(1.50)]=0.564\), hence \(T_c=65.1^\circ\mathrm C\). At the surface multiply by \(\cos(0.6533)=0.794\), giving about 55.9 °C. Higher roots are strongly attenuated at this Fourier number.

A process requiring the centre to fall below 50 °C needs centre ratio \((50-20)/(100-20)=0.375\). Solve \(Fo=\ln(1.070/0.375)/0.6533^2=2.46\), or approximately 984 s. By contrast a lumped estimate gives \(Fo=-\ln(0.375)/0.5=1.96\), about 785 s. It underestimates the core cooling time by over three minutes because the film and internal gradients both matter. An early-time surface prediction requires more modes than this late-time centre criterion. In particular the first term alone gives a centre ratio above unity at time zero, signalling that the remaining terms are necessary to reconstruct the original uniform state.

If product quality depends on average energy content rather than the hottest spot, average the first-mode shape over half the thickness. Its factor \(\int_0^1\cos(\lambda_1 X)dX=\sin\lambda_1/\lambda_1=0.930\) gives mean excess ratio \(0.564(0.930)=0.525\) after 600 s. The predicted bulk temperature is therefore about 62.0 °C, between centre and surface as expected. A calorimetric measurement made after removing and mixing the material is closer to the mean than to either point thermometer. A decision to stop cooling based on such a reading can therefore satisfy an average enthalpy requirement while leaving the centre several kelvins above a local temperature limit.

The surface flux can be checked against the rate of thermal energy loss. At 600 seconds each face transfers \(50(55.9-20)=1795\,\mathrm{W/m^2}\) to the air. Per square metre of plan area the slab therefore loses approximately 3590 W. The volumetric heat capacity obtained independently from \(k/\alpha\) is \(2.0\times10^6\,\mathrm{J/(m^3K)}\). Multiplying by total 0.040 m thickness gives an areal capacity of 80000 J/(m² K), and a predicted instantaneous mean cooling rate \(3590/80000=0.0449\,\mathrm{K/s}\). Differentiating the one-term mean temperature gives the same decay rate to within rounding.

This independent balance is especially useful if measurements suggest two different film coefficients on opposite sides. An unequal pair of measured fluxes cannot be fitted by a strictly symmetric half-slab model even if it reproduces one centre temperature. The full-thickness conduction problem then requires both surface boundary conditions; simply replacing them by their arithmetic mean may match total heat over one interval while shifting the hottest location away from the midplane.

Interactive calculation · Change the inputs of this example

Change the parameters of this reference plot and compare its limiting cases. The fixed illustration remains beside the derivation; the adjustable calculation exposes the same dependence on geometry, material properties or loading.

Study the full derivation

Periodic heating as a measurement of thermal diffusivity · Thermal processes and transport in engineering

Two buried thermometers see the same applied surface temperature oscillation with different amplitudes and phases. Derive how a solid filters that oscillation, recover diffusivity independently from both observations and identify when a rear boundary or a poor sensor contact changes the inference.