Each volume develops its arguments in sequence, with worked problems and links to experiments.
Thermal processes and transport in engineering
Close energy and entropy balances around real processes. Use measured states and heat flows to separate component performance from modelling assumptions.
How the course fits together
- Chapters 1–4
Choose first a closed system, then a flowing control volume. Energy balances determine work and heat, entropy restricts their conversion, and returning to the initial state creates a cycle whose performance can be measured.
- Chapters 5–8
A thermal resistance sets a steady heat rate. Adding storage makes temperatures time-dependent. Phase change and moist air then require tracking composition as well as sensible energy.
- Chapters 9–12
Use a reference environment to measure available work. Follow water around a steam cycle, transfer energy between two moving streams, and close the course with radiative exchange between surfaces.
Chapters
- State, process and the first law for a closed system
Distinguish properties from path-dependent transfers and determine heat and work for a piston-cylinder process.
- Open systems, enthalpy and steady-flow devices
Use an inlet-outlet balance to distinguish shaft work, kinetic-energy conversion and pressure reduction.
- Entropy, irreversibility and useful-work loss
Check a proposed process with the second law and quantify the effect of a finite temperature difference.
- Thermodynamic cycles, refrigeration and phase change
Analyse a vapour-compression cycle from supplied state properties and compare its performance with a reversible bound.
- Steady conduction, thermal resistance and insulation
Derive the heat leak through a cylindrical wall and identify when increasing insulation thickness can increase heat transfer.
- Thermal diffusion and transient surface cooling
Use diffusion time, Biot number and penetration depth to choose between a uniform-body model and a spatial temperature field.
- Phase equilibrium and steam quality
Locate a two-phase state from two independent measurements and use mass fractions to find its volume and energy.
- Gas mixtures, humidity and condensation
Translate relative humidity into a water mass balance and determine how much condensate a cooling coil removes.
- Useful work and exergy destruction
Evaluate the useful-work potential of a steady stream and distinguish energy conservation from the destruction of useful-work potential.
- Steam power cycles and turbine efficiency
Close a Rankine cycle energy balance and predict how turbine irreversibility changes power, condenser duty and exhaust quality.
- Heat-exchanger effectiveness and finite capacity rates
Derive the counterflow effectiveness relation and determine outlet temperatures when neither stream temperature is fixed.
- Thermal radiation and enclosure exchange
Use surface emission and reflected irradiation to derive the net heat exchange between parallel grey surfaces.
Further chapters and interactive tutorials
- Choosing a pressure ratio for a gas-turbine cycle
Why does a bigger pressure ratio eventually reduce the work from a gas turbine? Follow one kilogram of gas round four devices, keep separate accounts for heat and work, and see what changes when the compressor and turbine are imperfect.
- Why a real gas cools or warms across a throttle
A gas passes through an insulated porous plug. Its pressure drops and its measured temperature changes. Start with the energy flowing through the plug and obtain a prediction from the equation of state.
- When another centimetre of cooling fin stops helping
A fin adds surface area, but heat must travel down its length before it can reach that area. Derive the temperature profile from an energy balance and quantify how much of the nominal area contributes to cooling.
- A moving boundary in a freezing layer
A flat cold surface grows a layer of ice from water initially at its melting temperature. Estimate when it will reach a specified thickness, then discover how a finite heat-transfer resistance changes its early growth.
- Diffusion with a stationary carrier gas
A solvent evaporates into a gas layer. Its molecules diffuse relative to the mixture, while evaporation also induces a bulk molar flow. Work through the species balances to see why the flux ceases to scale linearly with surface concentration.
- Reading a vapour-compression refrigerator from its four enthalpies
A cooling machine circulates refrigerant through a compressor, condenser, valve and evaporator. Follow one kilogram around the circuit and see why compressor efficiency and liquid subcooling change the coefficient of performance by different mechanisms.
- Finding the vapour fraction of an equilibrium flash
A mixture enters a separator at given overall composition, pressure and temperature. Some components prefer the vapour more strongly than others. Derive a scalar equation for the fraction that evaporates and test for a two-phase solution before iterating.
- Where a thermoelectric cooler rejects its heat
A detector has to operate ten kelvin below the laboratory air temperature. A thermoelectric module beneath it can transport heat against that temperature difference when an electric current flows. Increasing the current also generates heat inside the module and warms its heat sink. Build an energy balance that predicts when additional current helps, when it costs more than it delivers and why a nominal cooling-capacity figure alone cannot specify an operating point.
Computational notebooks
Run the Python calculations in your browser and compare the figures with the derivations.
Problem sheets
Sheets 1–6 accompany the first twelve chapters. The final projects bring several methods together. Attempt each stage before opening its worked solution.
- Energy accounts for stored and flowing matterFor chapters 1 and 2
Draw a boundary, identify work and heat with consistent signs, and test the effect of changing the boundary.
- Entropy production and performance limitsFor chapters 3 and 4
Calculate an irreversibility and use a reversible benchmark to assess engines and refrigerators.
- Heat paths and temperature historiesFor chapters 5 and 6
Identify which geometry sets a thermal resistance, and decide whether a transient can be represented by one temperature.
- Saturation and moist airFor chapters 7 and 8
Infer phase mass fractions from measured properties and use dry-air balances through cooling and mixing processes.
- Exergy and steam-cycle performanceFor chapters 9 and 10
Compare useful-work bounds with actual work and estimate separate turbine and pump contributions to a power cycle.
- Heat exchangers and radiation shieldsFor chapters 11 and 12
Relate thermal conductance and surface properties to local temperature differences and net energy transport.
- Budgeting cooling power for a freezing experiment
A cold plate grows a planar ice layer while a metal support fin conducts heat into the cold enclosure. Construct an energy budget that distinguishes the rate at which the front moves, the total latent heat extracted, and the electrical input of the refrigerator.
- Separate heat capacity, contact conductance and leakage in a calorimeter
Two small metal assemblies, each internally close to uniform temperature, are joined through a removable thermal contact. Their thermometer traces approach one another. Use the common final temperature, the transient temperature difference and the subsequent slow drift to decide which combinations of thermal properties the experiment can identify.
Final synthesis problem · Close the energy and exergy balances of a heat exchanger
Applied study
Size a heat exchanger from energy balances and determine the temperature limits of the design.
Follow energy through an open system
A heat exchanger recovers energy from a warm process stream to preheat an incoming cold stream. A turbine also cools a stream, yet delivers shaft work. A steady-flow control volume distinguishes the mechanisms. Neglect changes in kinetic and potential energy and let heat into the control volume and shaft work out be positive. For one inlet and one outlet the first law reads \(\dot Q-\dot W=\dot m(h_{\rm out}-h_{\rm in})\), where \(h\) is specific enthalpy. For an ideal gas with constant specific heat, or a liquid stream with constant specific heat and negligible pressure change,
Draw a boundary around an insulated exchanger containing both streams. With no shaft work, any heat given up by the hot stream must appear in the cold stream. Define heat-capacity rates \(C_h=\dot m_hc_{p,h}\) and \(C_c=\dot m_cc_{p,c}\), measured in W/K. The positive rate of internal heat transfer is
The smaller capacity rate limits the possible transfer to \(\dot Q_{\max}=C_{\min}(T_{h,i}-T_{c,i})\). Energy balance alone gives one equation for the two outlet temperatures. The missing information is how much surface and thermal conductance connect the streams.
Derive the counterflow temperature profile
Let \(x\) increase in the hot-stream direction. The cold stream enters at the other end. Per unit length, a strip of wall of width \(w\) transfers \(Uw(T_h-T_c)\). Assume steady operation, constant overall coefficient \(U\), no external losses and negligible axial conduction. A slice balance gives
Both slopes are negative in this coordinate. A cold parcel warms as it moves towards decreasing \(x\).
Take \(C_h=C_{\min}\), \(C_r=C_h/C_c\) and \(\mathrm{NTU}=UA/C_h\), with transfer area \(A=wL\). Subtract the slice balances. The local temperature difference at \(L\) divided by its value at zero is \(\exp[-\mathrm{NTU}(1-C_r)]\). Substitute the two stream balances above to eliminate the outlet temperatures. The resulting effectiveness is
With equal capacity rates the difference is constant along the wall, and the limiting effectiveness is \(\mathrm{NTU}/(1+\mathrm{NTU})\). With a vanishing area there is no exchange. These limits provide simple checks on the algebra.
Worked example · Two water channels
Use \(T_{h,i}=350\) K, \(T_{c,i}=290\) K, \(C_h=0.0054\) W/K and \(C_c=0.0090\) W/K. The wall and fluid films together give \(U=90\) W/(m² K) over \(A=0.045(0.002)=9.0\times10^{-5}\) m². Thus \(C_r=0.60\), \(\mathrm{NTU}=1.50\), and the exponential factor is
The effectiveness is 0.6727 and \(\dot Q_{\rm ex}=0.6727(0.0054)(60)=0.2180\) W.
The hot outlet is \(350-0.2180/0.0054=309.64\) K, and the cold outlet is \(290+0.2180/0.0090=314.22\) K. These outlets lie at opposite ends. The local hot-to-cold differences at the ends are \(350-314.22=35.78\) K and \(309.64-290=19.64\) K, both positive. For a body cooling in time against a reservoir, the same conductance enters a different energy balance. Study transient cooling of a solid.
Transfer problem · A compressor and turbine
In an ideal gas-turbine cycle, a compressor raises the pressure by a factor of 8, heat is supplied at constant pressure and the turbine expands the stream back to its starting pressure. Let air enter the compressor at 300 K and the turbine at 1200 K. Assume ideal-gas air with constant \(\gamma=1.4\) and \(c_p=1.005\) kJ/(kg K), reversible adiabatic compression and expansion, and negligible pressure losses. For either isentropic machine \(T_{\rm out}/T_{\rm in}=(p_{\rm out}/p_{\rm in})^{(\gamma-1)/\gamma}\).
The pressure factor raised to the temperature exponent is
The compressor therefore discharges at 543.4 K and the turbine at 662.5 K. By the steady-flow first law the turbine delivers \(c_p(1200-662.5)=540.2\) kJ/kg of work, while compression requires \(c_p(543.4-300)=244.6\) kJ/kg. The net output is 295.6 kJ/kg. Dividing by the heat input \(c_p(1200-543.4)=659.9\) kJ/kg gives an ideal thermal efficiency of 44.8%. The exhaust is hotter than the compressed air by about 119 K, so those two streams offer an opportunity for recuperation before further heat is supplied.
Exercises
1. Size the exchanger at fixed flow
Keep both original capacity rates and \(U\) fixed. What area gives \(\varepsilon=0.80\)? How long would the 2 mm wide wall need to be?
Show the sizing calculation
Inverting the effectiveness formula gives
Then
The extra area supplies diminishing gains as the end temperatures approach one another.
2. Check the second law
For the original insulated exchanger assume negligible pressure drops and incompressible streams. Use the logarithmic entropy change of each stream to find the entropy-generation rate.
Show the second-law balance
At steady state \(\dot S_{\rm gen}=C_h\ln(T_{h,o}/T_{h,i})+C_c\ln(T_{c,o}/T_{c,i})\). The hot stream loses entropy and the cold stream gains more. Substitution of 309.638 K and 314.217 K gives \(6.02\times10^{-5}\,\mathrm{W/K}\). The positive result is consistent with transfer through a finite temperature difference.
OneSimulation laboratory
Explain why greater exchanger effectiveness can give less power
Compare recorded OneSimulation runs on this page. To test your own inputs, download the notebook and model files and run the model in an activated OneSimulation environment.
Run the heat-exchanger example at ntu=1.5, capacity_ratio=0.6 and inlet temperatures 350 and 290 K. Record both cross-section-averaged outlet temperatures and the power lost by the hot stream. In this code the geometry and conductance are fixed. Changing ntu changes the computed capacity rates and inlet speeds.
- Set
ntu=3.0at the original capacity ratio. Both flows halve. The one-dimensional model predicts an effectiveness of 0.853 and a hot outlet near 298.8 K. The heat rate should fall, despite the greater effectiveness, since there is now less hot water to cool every second. - Restore
ntu=1.5and setcapacity_ratio=0.3. The hot capacity stays fixed and the cold capacity doubles. Expect a lower cold outlet (about 303.1 K) and an increased heat rate (about 0.235 W). Check both energy balances against the numerical solution.
| NTU and capacity ratio | Hot outlet (K) | Cold outlet (K) | Heat rate (W) |
|---|---|---|---|
| 1.5, ratio 0.60 | 309.84 | 314.20 | 0.2168 |
| 3.0, ratio 0.60 | 299.36 | 320.79 | 0.1367 |
| 1.5, ratio 0.30 | 306.62 | 303.11 | 0.2343 |

As a numerical balance check, also calculate the heat gained by the cold stream. The two outlet-based estimates differ by about 0.5% in the baseline and 1.4% at NTU 3. Refining the mesh lets you test how much of this discrepancy comes from the spatial approximation.
View the OneSimulation counterflow model and its temperature profiles.
Download experiment files (ZIP) Extract the files together and open counterflow_heat_exchanger_ntu.ipynb in a local OneSimulation environment.
Interactive reference for the OneSimulation laboratory
Change capacity rates through NTU at fixed conductance and check both outlet temperatures. The browser evaluates the1D counterflow energy-balance reference.
Problem sheet 6 · Recover an exchanger capacity rate from outlet data
Advanced study across the subject
Each sequence connects the course to detailed chapters in neighbouring subjects. The complete course PDF includes their derivations, examples and exercises.
Properties, equilibrium and phase change
Predict the sign of a response from a potential, then track what a measured fraction or coexistence curve says about the state of the material.
Transport, heat sources and diagnostics
Separate sensible heating from transported or radiated energy. Test the temperature signal against a field loss measurement and a conservative heat discretisation.
A worked application in field physics
Close a calorimetric energy budget around a magnetic core and compare heat per cycle with the area of its hysteresis loop.
Measuring magnetic core loss by a hysteresis loop and by calorimetry
Further reading
Trace states around the Rankine and Brayton cycles. Reconstruct the work and heat transfers from the property data before comparing cycle efficiencies. MIT · Thermodynamics and Propulsion
Extend the heat-exchanger work by separating wall, film and contact resistances. Identify the assumption that allows a single overall heat-transfer coefficient. Lienhard and Lienhard · A Heat Transfer Textbook