One model supplies many possible targets
For parameters \(\theta\) with posterior mean \(m\) and covariance \(C\), a linear target \(s=h^T\theta\) has mean \(h^Tm\). Subtract the mean and expand the quadratic product to obtain
An independent sensor with variance \(R\) changes the variance of a future measured value to \(h^TCh+R\). Repeated fits of noisy datasets and repeated physical measurements are distinct sources of variation.
A candidate new observation \(z=a^T\theta+\epsilon\) with variance \(R_a\) has covariance \(h^TCa\) with the target. For a Gaussian posterior the conditional covariance update is \(C_+=C-Caa^TC/(a^TCa+R_a)\), found either by completing the square or projecting out the optimal multiple of the innovation. The target variance decreases by
Background · Posterior predictive
A distribution over parameters induces uncertainty in a new observation. Measurement noise and uncertainty of the prediction mean are distinct contributions.
A precise sum and an uncertain difference
Let \(C\) have diagonal entries 1 and correlation \(-0.9\). A target \(h=(1,1)\) has variance \(2-1.8=0.2\). The difference \(h=(1,-1)\) has variance 3.8. Ignoring correlations would predict 2 for both. With sensor variance 0.25, a newly measured sum has variance 0.45 although the latent sum variance remains 0.2.
For the target sum, measuring the first coordinate with variance 0.25 reduces variance by \((1-0.9)^2/(1+0.25)=0.008\). Measuring the sum itself at the same variance reduces it by \(0.2^2/(0.2+0.25)=0.0889\). These two sensors have differently normalised sensitivity vectors. Their stated noise levels refer to their own output units and must be calibrated before a cost comparison.
Choose the measurement direction
For a fairer geometric comparison, restrict both measurement and prediction directions to unit length. Fix the target along the normalised sum. Sweep candidate observation angles and read the remaining prediction variance. Change the parameter correlation: when does a coordinate sensor improve the target appreciably?
Tutorial on prediction and parameter recovery
If \(h^TCa=0\), can a noise-free measurement of \(a^T\theta\) improve the linear prediction under these Gaussian assumptions?
Worked solution
The covariance reduction is exactly zero. The measurement may determine another direction precisely while carrying no linear information about the target.
The posterior on \(\theta\) is strongly non-Gaussian. Which conclusions still hold exactly?
Worked solution
Mean and variance of a fixed linear prediction still follow from its first two moments, and independent sensor variance still adds. The Gaussian conditional update and an interval based only on two standard deviations need additional assumptions.
Read the university treatment
Compare the projection of a vector measurement with the covariance of a scalar target. Check the direction of each matrix product. Stephen Boyd · Stanford EE363, estimation