Diagonalise the differential operator on the periodic interval
Use a dimensionless coordinate \(0\le x<2\pi\) and solve \(u_t=\kappa u_{xx}\) with periodic values and periodic derivatives. The complex exponentials \(e^{imx}\), with integer m, satisfy both conditions and are eigenfunctions of the second derivative. Put \(u(x,t)=A_m(t)e^{imx}\) and cancel the common exponential. The scalar amplitude equation is
Thus every cosine or sine mode decays by \(\exp(-\kappa m^2t)\), with no phase shift, while the m=0 mean is conserved.
On a uniform grid \(x_j=2\pi j/N\), the samples of \(m\) and \(m+\ell N\) agree for every integer \(\ell\). A discrete Fourier transform returns coefficients in one representative band. For the real cosine test with even N we can fold a positive physical mode into \(k=\min(r,N-r)\), \(r=m\bmod N\). A Fourier spectral Laplacian multiplies that coefficient by \(-k^2\). For a resolved mode it differentiates the trigonometric interpolant exactly, up to arithmetic. For unresolved data it differentiates the aliased representative; no operation using only those samples can identify the original m.
Apply the centred difference stencil to a single wave
The standard second difference is \((u_{j+1}-2u_j+u_{j-1})/h^2\), \(h=2\pi/N\). Put the grid wave \(u_j=e^{ikjh}\) into the stencil. Factor out the common phase and simplify with \(e^{i\xi}+e^{-i\xi}=2\cos\xi\). This gives the symbol and its small-h expansion:
The effective squared wavenumber is smaller than \(k^2\) for every nonconstant mode in the resolved band, so this spatial approximation decays too slowly if the time equation is integrated exactly. The error is modest when \(kh\ll1\), but at the Nyquist mode \(kh=\pi\) the ratio is
A stable time integrator cannot repair this spatial attenuation error without additional modeling. The experiment exponentiates both discretizations' symbols exactly, isolating space and sampling here.
Measure separate errors with the same sampled initial data
Choose \(\kappa=0.5,\ m=3,\ N=16\). The true squared wavenumber is 9 and the difference stencil gives 8.006. Starting at unit amplitude, at \(t=0.20\) exact and spectral amplitudes are 0.40657; finite differences give 0.44906. Doubling N to 32 changes the difference result to 0.41716. The absolute amplitude error falls from 0.04249 to 0.01059, a ratio of 4.01 consistent with the second-order expansion. This is a spatial-convergence study because time evolution introduces no truncation error.
Now take \(m=12,\ N=16\). Every sampled cosine equals the low mode \(k=4\) at \(t=0\). At \(t=0.02\), the continuum amplitude for the true physical mode is \(e^{-1.44}=0.237\), whereas the spectral grid predicts
A spectral computation can therefore agree exactly with its trigonometric interpolant and disagree strongly with the evolution of the intended signal. Sampling on a finer grid or obtaining prior bandwidth information resolves that ambiguity. The mean mode is particularly revealing when a nonconstant physical cosine aliases to a constant.
Start at mode 3 and successively double N from 8 to 32. Compute two amplitude-error ratios at the same time. Then use mode 12 on 16 points to observe an alias, and increase N until the Fourier grid represents the intended mode.
Tutorial · resolve a damping rate to a target tolerance
For a mode well inside the grid bandwidth, estimate the number of samples per wavelength needed for a relative error below 1% in the decay rate with centred differences. Test the estimate for \(m=2\). How could the time integrator contaminate a measurement of this spatial error?
Show the resolution estimate
Writing p for samples per wavelength gives
The relative rate error is approximately \((kh)^2/12\). Requiring at most 0.01 gives \(p\gtrsim18.14\); try 19 samples per wavelength, or \(N=38\) for \(m=2\). The exact ratio \([\sin(\pi/19)/(\pi/19)]^2\) is about 0.991. A forward-Euler step would replace exponential propagation by \(1-\kappa k_{\rm eff}^2\Delta t\). Its repeated-step error could partly mask the underdamping of the spatial stencil. Compare with the exponential of the discrete symbol before attributing a measured rate to space alone.
Further reading · Lloyd N. Trefethen, Spectral Methods in MATLAB · periodic grids, Fourier differentiation and downloadable programs
Check the discrete eigenvalue with OneSimulation
A spatial sine also diagonalises the five-point Dirichlet Laplacian on a square. Use the same modified wave-number argument in both coordinate directions. Run python poisson-mode.py --mode 2 --cells 8 16 32 and compare the observed nodal error with the discrete eigenvalue prediction in the CSV. This is a steady forced problem whose spatial operator can be checked independently of any time integrator. Download the OneSimulation verification model.
Study the full derivation
A Fourier Poisson solver and the trouble caused by unresolved products · Spatial discretisation and field equations
In a periodic medium the constant part of a source decides whether a Poisson problem has any solution. Derive the Fourier solver, separate spectral and finite-difference symbols, and see how a nonlinear product can inject a false low-frequency source.