Fundamentals / Mechanical engineering / Engineering thermodynamics and heat transfer

Diffusion with a stationary carrier gas

A solvent evaporates into a gas layer. Its molecules diffuse relative to the mixture, while evaporation also induces a bulk molar flow. Work through the species balances to see why the flux ceases to scale linearly with surface concentration.

Choose the reference frame for a flux

Let A be the evaporating species and B an insoluble carrier. A planar film of thickness L lies between the evaporating surface, at mole fraction \(y_s\), and a well-mixed reservoir at \(y_\infty<y_s\). Keep total pressure, temperature, total molar concentration \(c=p/(RT)\) and binary diffusivity D uniform. In a stationary laboratory frame the total species flux equals diffusion relative to the molar-average velocity plus transport by that velocity. If positive z points towards the reservoir, write

\[N_A=-cD{dy_A\over dz}+y_A(N_A+N_B).\]

Steady conditions in one dimension make \(N_A,N_B\) independent of z. Carrier B cannot enter the liquid and has zero net flux there. This fixes \(N_B=0\) throughout the film. B still diffuses towards the interface relative to the moving mixture. Its diffusive flux balances its outward convective flux. The constraint \(N_A+N_B=0\) would instead describe equimolar counterdiffusion between two exchanging species.

Separate variables and enforce both boundary concentrations

Collect the terms in \(N_A\), divide by \(1-y_A\) and integrate from the surface to the reservoir. The remaining integral is a logarithm of the carrier mole fraction.

\[N_A(1-y_A)=-cD{dy_A\over dz},\]
\[N_A={cD\over L}\ln{1-y_\infty\over 1-y_s}.\]
\[1-y_A(z)=(1-y_s)\left({1-y_\infty\over1-y_s}\right)^{z/L}.\]

The concentration profile curves because a given net flux requires a different concentration gradient at different carrier fractions. A dilute expansion of the logarithm gives

\[N_A\simeq(cD/L)(y_s-y_\infty).\]

The exact-to-dilute flux ratio exceeds unity when the surface emits A. The discrepancy becomes measurable long before the carrier disappears. At fractions very close to unity, the assumptions of a stagnant, isothermal film also deserve new scrutiny.

Small and large amounts of vapour at the surface

At 300 K and 1 bar, \(c=40.09\) mol/m³. Take \(D=2.0\times10^{-5}\) m²/s and \(L=5\) mm. The coefficient \(cD/L=0.1604\) mol/(m² s). With a vapour-free reservoir and \(y_s=0.05\), the logarithm is 0.05129 and the predicted flux is 0.00823 mol/(m² s). A linear gradient would give 0.00802, about 2.5% lower.

For \(y_s=0.50\), the flux rises to 0.111 mol/(m² s), versus 0.0802 for the dilute estimate. At mid-depth the exact fraction is \(1-\sqrt{0.5}=0.293\), while linear interpolation gives 0.25. An experimental check can therefore use either a mass-loss measurement or a local concentration measurement. Evaporative cooling changes the saturation mole fraction at the surface, so a measured surface temperature matters even if room temperature seems stable.

Use a vapour-free reservoir and increase the surface fraction from 0.10 to 0.80. Estimate which midpoint concentration lies farther from linear interpolation. Compare the resulting flux errors and identify the physical transport term responsible.

Tutorial · recover the effective film thickness

At the same temperature and diffusivity the surface mole fraction is 0.30, the reservoir fraction is 0.05 and a balance reports \(N_A=0.050\) mol/(m² s). Estimate L. What film thickness would be inferred if the outward molar flow were ignored?

Show the two fits

Solving the exact expression gives

\[L=cD\ln(0.95/0.70)/N_A=4.90\,\mathrm{mm}.\]

The linear fit yields

\[L=cD(0.25)/N_A=4.01\,\mathrm{mm}.\]

The latter fit makes the film thinner to compensate for omitted advection. In an experiment that effective thickness would predict the wrong flux when the surface composition changes appreciably.

Further reading · Lienhard and Lienhard · A Heat Transfer Textbook, chapter 11 on mass transfer by diffusion