Fundamentals / Mechanical engineering / Engineering thermodynamics and heat transfer

Finding the vapour fraction of an equilibrium flash

A mixture enters a separator at given overall composition, pressure and temperature. Some components prefer the vapour more strongly than others. Derive a scalar equation for the fraction that evaporates and test for a two-phase solution before iterating.

Connect composition to the equilibrium ratios

Let \(F=L+V\) be the total molar feed and liquid and vapour flow rates. Overall component fractions are \(z_i\), liquid fractions \(x_i\) and vapour fractions \(y_i\). At equilibrium the chemical potential of each species agrees across phases. In an ideal gas over an ideal liquid this reduces to Raoult's law \(y_i p=x_i p_i^{\rm sat}(T)\), so \(K_i=y_i/x_i=p_i^{\rm sat}(T)/p\). A larger K enriches that species in the vapour. For a real mixture K can depend on phase composition and require an outer property iteration. Here use fixed positive K values to isolate the material balance.

Eliminate the component flows

Define \(\beta=V/F\). Component conservation gives

\[z_i=(1-\beta)x_i+\beta y_i=x_i[1+\beta(K_i-1)].\]

Thus \(x_i=z_i/[1+\beta(K_i-1)]\). For both compositions to sum to one, enforce \(\sum_i(y_i-x_i)=0\), giving the Rachford–Rice equation:

\[R(\beta)=\sum_i{z_i(K_i-1)\over1+\beta(K_i-1)}=0,\]
\[R'(\beta)=-\sum_i{z_i(K_i-1)^2\over[1+\beta(K_i-1)]^2}.\]

The denominators are positive for \(0\le\beta\le1\). With at least one non-unity K of positive feed fraction, R decreases strictly, so at most one physical root exists. A positive R(0) and a negative R(1) bracket two phases. If \(R(0)\le0\) the stable fixed-K split is all liquid; if \(R(1)\ge0\) it is all vapour, with equality corresponding to incipient phase appearance. When every K is one this balance cannot specify \(\beta\). A bracketed numerical method preserves the meaningful interval even near a phase boundary.

Perform a binary flash and change the feed composition

Choose \(K_A=2,\ K_B=0.5,\ z_A=z_B=0.5\). Then

\[R(0)=0.25,\ R(1)=-0.25.\]

Multiplying by the two denominators gives \(0.25-0.50\beta=0\), hence \(\beta=0.50\). Liquid fractions are \(x_A=1/3,\ x_B=2/3\), and vapour fractions are

\[y_A=2/3,\ y_B=1/3.\]

For 10 mol/s feed each outlet carries 5 mol/s. The A balance reads \(5(1/3)+5(2/3)=5\) mol/s.

Increase \(z_A\) to 0.60 at the same T, p and K. The physical root becomes \(\beta=0.80\). The phase compositions remain at the same two endpoints; their proportions change to accommodate the new feed. Indeed the overall A fraction is

\[0.20(1/3)+0.80(2/3)=0.60.\]

At \(z_A=0.75\) the feed lies beyond the vapour endpoint. Then R(1) is positive, and searching outside the interval would produce a vapour fraction above unity. Report a single vapour phase instead. An adiabatic flash at unknown temperature would require a further enthalpy balance.

Start from equal feed fractions and increase the fraction of A until the root leaves the physical interval. Predict which pure-phase endpoint is reached. Compare residual signs at both endpoints before interpreting the reported phase.

Tutorial · determine whether an iteration is warranted

At an operating point take \(K_A=3,\ K_B=0.6\). Compute the liquid and vapour A fractions when both phases coexist. For \(z_A=0.30\), calculate \(\beta\). Repeat the phase test for \(z_A=0.10\) and explain why normalized hypothetical phase compositions can hide a failed balance.

Solve phase closure and the lever rule

Vapour closure gives \(3x_A+0.6(1-x_A)=1\), hence \(x_A=1/6\), \(y_A=1/2\). For overall fraction 0.30,

\[\beta=(0.30-1/6)/(1/2-1/6)=0.40.\]

At \(z_A=0.10\),

\[R(0)=0.10(2)+0.90(-0.4)=-0.16.\]

The feed remains liquid. Renormalizing an unphysical trial vapour composition could make it sum to unity while violating the original component and equilibrium equations. Check the physical endpoint signs first.

Further reading · Penn State, PNG 520 · elementary vapour–liquid equilibrium, flash objective function and numerical solution