Balance a short slice with distributed convection
Consider a straight prismatic fin of conductivity k, cross-section A, exposed perimeter P and length L. Hold the root at \(T_b\), let a fluid at \(T_\infty\) surround the fin and use a uniform convection coefficient h. Temperature is assumed nearly uniform across each cross-section. A small transverse Biot number \(h(A/P)/k\) supports that assumption. Ignore radiation and heat loss from the tip. Define \(\theta=T-T_\infty\). The axial heat entering a slice, less the heat leaving its far face, must equal \(hP\theta\,dx\).
A positive temperature excess makes the heat flow diminish downstream. For an insulated tip \(q_x(L)=0\), so a hyperbolic cosine centered at the tip satisfies the zero-slope condition. Its coefficient follows from the root temperature.
Efficiency follows by comparing with an isothermal fin
If every part of the lateral area stayed at \(T_b\), the heat transfer would be \(hPL\theta_b\). The actual-to-ideal ratio is therefore
For small mL the temperature falls little along the wall and doubling the area nearly doubles the heat flow. For large mL the root heat flow approaches \(kAm\theta_b\). Near the long-fin limit increasing conductivity or the root cross-section can buy more cooling than adding length. Efficiency alone does not measure total heat removal because it contains the nominal area in its denominator.
Two fins made from the same stock
Use a rectangular aluminium strip, 20 mm wide, 2 mm thick, \(k=200\) W/(m K), \(h=25\) W/(m² K) and \(\theta_b=50\) K. All four long faces are exposed. With \(A=4.0\times10^{-5}\) m² and \(P=0.044\) m, \(m=11.73\) m⁻¹. At 50 mm length, \(mL=0.586\), \(Q_b=2.47\) W and \(\eta_f=0.899\). The tip remains about 42.5 K above ambient.
At 150 mm, the heat rate is 4.43 W and the efficiency drops to 0.536. The material and exposed area tripled, while the heat transfer increased by about 79%. A fin root bonded through a finite contact resistance \(R_c\) would run cooler than the heated base. Replacing the temperature excess by \(T_{\rm base}-T_\infty-Q_b R_c\) in the root heat equation gives a direct way to include the bond in a thermal circuit.
Choose a short fin and inspect how far the infinite-fin approximation is from the insulated-tip temperature. Increase length until the root heat rate is almost saturated. Estimate the added cooling from another centimetre at that point.
Tutorial · select a length from a marginal-benefit criterion
For the same strip, require 95% of the infinitely long fin's heat rate. Find the required length. Then estimate the heat rate if the base is held 50 K above ambient through a contact resistance of 1 K/W.
Show the inverse calculation
Set \(\tanh(mL)=0.95\), giving \(mL=\tfrac12\ln(1.95/0.05)=1.832\) and \(L=0.156\) m. The root conductance there is \(G=kAm(0.95)=0.0891\) W/K. Adding the contact resistance gives
The temperature drop across the contact is about 4.09 K. This check distinguishes the fin-root temperature from the base temperature reported by a sensor under the bond.
Further reading · Lienhard and Lienhard · A Heat Transfer Textbook, chapter 4 on conduction and fins