Fundamentals / Mechanical engineering / Engineering thermodynamics and heat transfer

Phase equilibrium and steam quality

Locate a two-phase state from two independent measurements and use mass fractions to find its volume and energy.

From first principles

Derive the slope of a pure-substance coexistence line

At liquid–vapour equilibrium, transferring a small amount of matter between phases cannot lower the total Gibbs energy. For a pure substance this requires equality of the specific Gibbs energies \(g_f=g_g\) at common temperature and pressure. To find how pressure must change when temperature changes while maintaining coexistence, differentiate this equality along the saturation curve. The fundamental differential \(dg=-s\,dT+v\,dp\) gives

\[-s_f\,dT+v_f\,dp=-s_g\,dT+v_g\,dp .\]

Rearranging expresses the measured slope as the entropy change of vaporization divided by its specific-volume change. Reversible phase change at constant temperature absorbs specific enthalpy \(h_{fg}=T(s_g-s_f)\), so

\[\left(\frac{dp}{dT}\right)_{\rm sat}=\frac{s_g-s_f}{v_g-v_f}=\frac{h_{fg}}{T(v_g-v_f)} .\]

The units are Pa/K. No ideal-gas approximation has been made. If the vapour is dilute and the liquid volume negligible, further substitution can simplify the slope, but this fails near the critical point. The slope describes neighbouring coexistence states; determining a system’s vapour mass fraction additionally requires an extensive property such as specific enthalpy or volume.

Background · Vapour quality
\[x=m_v/(m_v+m_l)\]

This mass fraction applies in a two-phase equilibrium region. Mole fraction, mass fraction and fraction of volume occupied by vapour can be very different.

Derivation and applications

Trace an isentropic pressure change through the saturation dome

A vapour fraction inferred from one property must reproduce the others at the same pressure. Consider a pure substance in local liquid–vapour equilibrium. Let \(x\) be the vapour mass fraction and use subscripts \(f,g\) for saturated liquid and vapour at the current pressure. Neglect interfacial contributions and assume each phase has the tabulated saturation state. Specific extensive properties then obey the lever rule because their totals add over the masses of both phases:

\[s=(1-x)s_f+xs_g=s_f+xs_{fg},\]
\[h=h_f+xh_{fg}.\]

In a steady adiabatic reversible expansion the entropy balance gives

\[s_2=s_1.\]

At the specified exit pressure solve the entropy relation before using the enthalpy relation:

\[x_{2s}=(s_1-s_{f,2})/s_{fg,2},\]
\[h_{2s}=h_{f,2}+x_{2s}h_{fg,2}.\]

This interpolation is physical only when \(0\le x_{2s}\le1\). For an actual adiabatic turbine with negligible kinetic-energy change, use isentropic efficiency \(\eta_t=(h_1-h_2)/(h_1-h_{2s})\) and check the actual phase state separately:

\[h_2=h_1-\eta_t(h_1-h_{2s}),\]
\[x_2=(h_2-h_{f,2})/h_{fg,2}\]

if the actual outlet is still a mixture. Irreversibility reduces extracted work, which can leave the exhaust drier at the same pressure. A drier exit therefore does not by itself demonstrate higher efficiency.

Worked example

Infer equilibrium quality for two expansion histories

At a low-pressure outlet take rounded steam properties \(h_f=192\), \(h_{fg}=2393\) kJ/kg, \(s_f=0.649\) and \(s_{fg}=7.50\) kJ/(kg K). Steam enters with \(h_1=3200\) kJ/kg and \(s_1=6.65\) kJ/(kg K). The reversible quality is \((6.65-0.649)/7.50=0.800\), giving \(h_{2s}=2107\) kJ/kg. For \(\eta_t=0.800\), the actual exit enthalpy is about \(2326\) kJ/kg and the quality \(0.892\). The actual specific work is about \(874\) kJ/kg.

Second application

Detect when a reported quality has no physical meaning

At the same outlet pressure an independent calculation gives \(h_2=2630\) kJ/kg. Interpolating would give

\[x=(2630-192)/2393=1.019.\]

Since the saturated vapour enthalpy is only \(2585\) kJ/kg, the enthalpy lies above the saturation range. The outlet is superheated; finding its temperature requires superheated-vapour properties. Reporting a vapour fraction above unity would hide a change of thermodynamic region.

Try it · Turbine quality

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Temperature can stay fixed while heat enters

In an open pan at a fixed ambient pressure, liquid water begins to boil at a particular temperature. Additional heat can then convert liquid to vapour while the temperature remains close to that value. Specifying both saturation temperature and saturation pressure of a pure substance does not locate a unique mixture state. Along the coexistence curve they are linked, and the fraction of material in each phase supplies the missing information. Outside that curve pressure and temperature can usually be used as independent coordinates for a simple compressible substance.

Define quality \(x=m_g/(m_f+m_g)\) as the vapour mass fraction, using subscripts \(f\) for saturated liquid and \(g\) for saturated vapour. A property such as volume or enthalpy is additive over the two masses when interfacial contributions are negligible. Writing \(V=m_f v_f+m_gv_g\) and dividing by total mass gives the mixing relation. The same derivation applies to specific internal energy, enthalpy and entropy.

\[v=v_f+x(v_g-v_f),\]
\[h=h_f+xh_{fg},\]
\[h_{fg}=h_g-h_f .\]

Quality lies between zero and one in a saturated mixture. A calculated value beyond either endpoint signals a single-phase state or inconsistent measurements. Temperature does not interpolate: both phases in equilibrium have the same temperature.

Distinguish vapour mass from space occupied

A closed vessel contains 2.00 kg of saturated water and steam at approximately 100 kPa in 0.500 m³. Use the supplied rounded values \(v_f=0.00104,\ v_g=1.694\,\mathrm{m^3/kg}\),

\[h_f=417.5,\ h_{fg}=2258\,\mathrm{kJ/kg}.\]

The measured specific volume is 0.250 m³/kg. Quality follows as \((0.250-0.00104)/(1.694-0.00104)=0.1471\). Thus vapour mass is 0.294 kg while 1.706 kg remains liquid.

The vapour occupies \(0.2941(1.694)=0.4982\,\mathrm{m^3}\), almost the entire vessel. The liquid occupies roughly 0.0018 m³. Specific enthalpy is

\[417.5+0.1471(2258)=749.6\,\mathrm{kJ/kg}.\]

Specific internal energy follows from \(u=h-pv=749.6-100(0.250)=724.6\,\mathrm{kJ/kg}\) when using kPa and m³/kg. A level indicator measures occupied volume; using its reading directly as a mass fraction would give a large error.

Connect latent heat to the coexistence curve

For two pure phases in equilibrium their specific Gibbs free energies are equal. Along the coexistence line this equality persists, so \(dg_f=dg_g\). From \(dg=v\,dp-s\,dT\) one obtains

\[dp_{\rm sat}/dT=(s_g-s_f)/(v_g-v_f)=h_{fg}/[T(v_g-v_f)].\]

At about 373 K using the same values, the slope is

\[2258/[373(1.693)]=3.58\,\mathrm{kPa/K}.\]

A small increase of boiling pressure by 3.6 kPa therefore raises saturation temperature by about one kelvin locally. Larger changes require integrating the changing properties or reading a saturation table rather than treating this local slope as a constant.

Predict flash after throttling

A saturated liquid with inlet enthalpy 500 kJ/kg passes through an insulated valve to the pressure of the drum above. With negligible work and velocity change, enthalpy remains 500 kJ/kg. The downstream quality is therefore

\[(500-417.5)/2258=0.0365.\]

Only about 3.7% of the water flashes by mass, but the large specific volume of the vapour can make its occupied volume dominate the downstream pipe.

Trace a saturated mixture along a constant-volume path

The drum example determines one state. If a sealed rigid vessel is heated, its pressure and temperature change together along saturation while its specific volume remains fixed. Provided equilibrium is maintained and no other phase appears, the quality at every pressure is

\[x=(v-v_f)/(v_g-v_f).\]

The energy equation for the vessel is \(Q=\Delta U\) when it does no boundary or shaft work. Replacing internal-energy change by enthalpy change would add the spurious \(V\Delta p\) term of a rigid container.

Quality does not change solely because latent heat has entered. Differentiate \(v=(1-x)v_f+xv_g\) along the saturation curve at fixed \(v\). This gives

\[\frac{dx}{dT}=-\frac{(1-x)\,dv_f/dT+x\,dv_g/dT}{v_g-v_f}.\]

Saturated liquid usually expands as temperature rises while saturated vapour specific volume decreases over the ordinary water range. The sign therefore depends on the initial mixture and local property slopes. A vessel containing almost all liquid by volume can, under some conditions, follow the saturated-liquid boundary on heating rather than drying out. Determine the actual phase region from the property data after each change. When \(v\) lies outside the interval between \(v_f\) and \(v_g\), a saturated quality formula is no longer applicable.

Find how much energy changes phase in a sealed vessel

Take 1.00 kg of water in a rigid 0.300 m³ vessel. Use rounded saturation data at 100 kPa:

\[v_f=0.00104,\ v_g=1.694\,\mathrm{m^3/kg},\ u_f=417.4,\ u_g=2506\,\mathrm{kJ/kg}.\]

At 200 kPa use \(v_f=0.00106,\ v_g=0.8857,\ u_f=504.5,\ u_g=2529\,\mathrm{kJ/kg}\). The volume bounds contain 0.300 m³/kg at both pressures. Initial quality is \((0.300-0.00104)/(1.694-0.00104)=0.1766\); final quality is

\[(0.300-0.00106)/(0.8857-0.00106)=0.3379.\]

Thus about 0.161 kg additionally evaporates.

Mixture internal energies are \(417.4+0.1766(2506-417.4)=786.3\,\mathrm{kJ/kg}\) and \(504.5+0.3379(2529-504.5)=1188.6\,\mathrm{kJ/kg}\), giving heat input about 402 kJ. Merely multiplying evaporated mass by one latent heat would overlook the sensible energy changes in each phase and the variation of saturation properties. As an independent check, \(\Delta H=\Delta U+V\Delta p\) exceeds the required heat by \(0.300(200-100)=30.0\,\mathrm{kJ}\). If additional heating brings saturated vapour specific volume down to 0.300 m³/kg, the last liquid disappears. Beyond that state the fixed-volume path enters the superheated region and one must determine temperature using a single-phase equation of state or superheated-vapour data.

The vapour volume fraction in the second state is \(m x v_g/V=0.3379(0.8857)/0.300=0.998\) approximately. Although about one third of the mass is vapour, almost every part of the vessel volume is vapour-filled. A level probe that detects a very small liquid volume is consistent with the presence of substantial residual liquid mass. This has a direct consequence for rounding: replacing \(v_f\) by zero only gives a modest error in calculated quality here, but using that same approximation to predict the remaining liquid depth gives a nonsensical zero. Retain the finite liquid volume whenever the question concerns an interface height or the mass recovered through a bottom drain.

The units of the property table matter just as much as the phase labels when predicting a small liquid inventory.

Can an equation of state predict energy changes during expansion?

A caloric model \(du=c_v\,dT\) works for an ideal gas. To discover the extra term for a real fluid, let \(v\), \(s\) and \(u\) denote molar volume, entropy and energy for a single homogeneous phase. At a fixed composition the fundamental relation is

\[du=T\,ds-p\,dv.\]

Introduce the Helmholtz energy \(f=u-Ts\). Then \(df=-s\,dT-p\,dv\). Equality of the two mixed partial derivatives of the smooth function \(f(T,v)\) gives the Maxwell relation \((\partial s/\partial v)_T=(\partial p/\partial T)_v\).

Now expand \(ds\) in \(T,v\). The term \(T(\partial s/\partial T)_v\) equals \(c_v\), obtained directly by holding \(v\) fixed in the fundamental relation. Substituting both coefficients gives

\[du=c_v\,dT+\left[T\left(\frac{\partial p}{\partial T}\right)_v-p\right]\,dv.\]

The bracket has units of pressure. For \(p=RT/v\) it vanishes. For a van der Waals model \(p=RT/(v-b)-a/v^2\), the repulsive volume correction cancels between the two terms and the attraction term leaves \(a/v^2\). Assuming constant \(c_v\), integration yields

\[\Delta u=c_v(T_2-T_1)+a(1/v_1-1/v_2).\]

An insulated, rigid container contains a gas on one side of a removable internal partition and vacuum on the other. Removing the partition causes no external boundary work and exchanges no heat. States before and after settling therefore have equal internal energy. Let \(T_1=300\,\mathrm K\), \(v_1=0.00200\,\mathrm{m^3\,mol^{-1}}\), \(v_2=0.00400\,\mathrm{m^3\,mol^{-1}}\), \(a=0.150\,\mathrm{Pa\,m^6\,mol^{-2}}\), \(b=4.0\times10^{-5}\,\mathrm{m^3\,mol^{-1}}\) and \(c_v=24.0\,\mathrm{J\,mol^{-1}K^{-1}}\). The volume contribution is

\[0.150(500-250)=37.5\,\mathrm{J\,mol^{-1}}.\]

To keep energy constant the temperature falls by \(37.5/24.0=1.56\,\mathrm K\), to \(298.44\,\mathrm K\). The differential identity links the equilibrium endpoints even though the actual expansion was irreversible. The value of \(b\) matters for their pressures and cancels from this energy change.

Practise on sheet 4 · Compare free and isothermal expansion of the same model gas. Further reading · University of Cincinnati · C. Vaz, Thermodynamics and Statistical Mechanics · §4.2 Maxwell Relations.