From first principles
How turns, permeability and a gap set the flux
Wind \(N\) turns around a closed magnetic core and drive a steady current \(I\). Use a core of length \(\ell_c\) and constant cross-section \(A\), interrupted by an air gap of length \(g\). Assume a linear core of permeability \(\mu_c\), a nearly uniform field through each cross-section and negligible leakage and fringing. Ampère’s law counts the linked current along a loop. Flux continuity through a thin pillbox at the interface gives a common normal \(B\):
The material relation \(B=\mu H\) is experimental input. Insert each material’s field into the loop balance, then multiply by area to obtain the flux \(\Phi=BA\):
The bracket is the reluctance. Each turn links the same flux, so the flux linkage is \(N\Phi\). For a linear core the coil inductance follows from flux linkage per current:
A gap can control \(L\) even when it occupies little of the magnetic path. Compare \(g/\mu_0\) with \(\ell_c/\mu_c\) before neglecting it. If the core saturates, the field-to-current ratio changes with the operating current.
Derivation and applications
Derive the inductance measured by a small alternating signal
A winding on a biased core can give different answers to two seemingly ordinary inductance measurements. Consider a narrow toroid with \(N\) turns, uniform cross-section \(A\), core path length \(\ell\) and one short air gap \(g\). Assume negligible leakage, fringing and hysteresis. Allow the core law \(H_c(B)\) to be nonlinear but single-valued. Flux conservation makes the induction \(B\) common to gap and core, while Ampère's law adds their distinct field integrals.
Here \(\Lambda\) is flux linkage. A slowly varying current superposed on a constant bias probes only a small interval of this curve. Differentiate the circulation equation about the operating induction \(B_0\) and define the differential permeability \(\mu_d=(dH_c/dB)^{-1}\) evaluated there.
The induced terminal voltage after subtracting winding resistance is \(d\Lambda/dt\). Thus the locally measured inductance is the slope. A DC current and a flux measurement instead give the chord joining the bias point to the origin. Writing \(\mu_s=B_0/H_c(B_0)\) makes that expression
These definitions coincide for a straight constitutive curve through the origin. A large air gap also makes the two estimates converge because the same linear air term then dominates each denominator.
Worked example
Predict the response to a sinusoidal probe
Change the inputs and investigate this derivation.
Take \(N=100\), \(A=100\) mm², \(\ell=100\) mm and \(g=0.500\) mm. At the selected bias suppose \(\mu_d=200\mu_0\) and \(\mu_s=1000\mu_0\). The incremental effective gap is \(0.500+100/200=1.00\) mm, giving \(L_d=1.26\) mH. The chord yields \(2.09\) mH. A 1.00 kHz current of 10.0 mA peak therefore produces a reactive voltage of \(2\pi f L_d I=79.0\) mV peak, provided the excursion stays within the nearly constant local slope.
Second application
Infer the material slope from a voltage ramp
Change the inputs and investigate this derivation.
A second winding has \(N=80\), \(A=150\) mm², \(\ell=120\) mm and \(g=0.200\) mm. An inductive voltage of 96.0 mV during a 40.0 A/s ramp gives \(L_d=2.40\) mH. Reversing the slope formula yields \(\ell/(\mu_d/\mu_0)=\mu_0 N^2A/L_d-g=0.303\) mm, so \(\mu_d/\mu_0\simeq396\). The positive residual is a check on subtracting the gap contribution before attributing the measured slope to the core.
Try it · Differential inductance
Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.
When does improving an iron core stop helping?
A narrow magnetic circuit has 20 cm of linear core material and a single adjustable air gap. The two regions have equal area. Neglect leakage and fringing. Predict whether buying material with twice the permeability can double the useful gap field.
Ampère's circuital law gives \(NI=B\ell_c/(\mu_0\mu_r)+Bg/\mu_0\), because the normal flux density is continuous and the area is constant. At zero gap the first term dominates. At \(g=\ell_c/\mu_r\) the two drops are equal. Notice that a millimetre of air can cost more magnetomotive force than the entire core.
Read the two curves at 1 mm for \(\mu_r=1000\). Explain why a change in gap width can matter more than a large change in core material. The ideal zero-gap end may exceed the range of a physically linear core.
A thick toroidal core carries different flux densities at its inner and outer edges
A closed toroidal core occupies inner radius \(a\), outer radius \(b\) and axial height \(h\), with rectangular cross section. An ideal closely distributed \(N\)-turn winding carries steady current \(I\). Assume negligible leakage outside the core, an axisymmetric toroidal field and a linear isotropic reversible constitutive law at first. A technician estimates the inductance by putting the full cross-sectional area on a circle halfway between the two radii. The estimate is convenient. The underlying field problem tells us where it is accurate, how early the inner material starts to saturate, and which region contributes most strongly to a measured flux linkage.
Use the correct circulation at each radius
For every circular path entirely within the core, Ampère's law for \(\mathbf H\) encloses the same free current \(NI\), independent of its radius. Cylindrical symmetry makes the tangential field constant on that particular circle. Hence \(H_\phi(r)=NI/(2\pi r)\). The inner material experiences the larger magnetising field. It is inappropriate to impose a uniform \(H\) across the full radial thickness simply because a single value of current feeds the winding.
Each radial strip of width \(dr\) presents area \(h\,dr\) normal to the flux. For uniform permeability \(\mu\), adding these strips gives the flux of one turn and linkage of the whole winding:
Contrast this with the arithmetic mean radius \(r_m=(a+b)/2\), which predicts \(L_m=\mu N^2h(b-a)/(2\pi r_m)\). Their ratio is \(\ln(b/a)/[(b-a)/r_m]\). For a narrow core write \(a=r_m(1-\delta), b=r_m(1+\delta)\). Expanding the logarithm gives
The leading error is quadratic in fractional half-thickness. The symmetry of the cross section cancels the first-order error around its midpoint while leaving the inner edge particularly important for local field limits.
Test inductance using the energy instead of flux linkage
The magnetic energy density in a reversible linear material is \(B H/2\). The volume of one radial shell is \(2\pi r h\,dr\). Insert the local \(H\), integrate and obtain
The radial integral includes \(1/r^2\) from squared field and \(r\) from the volume. Missing either yields the wrong radial weighting. A magnetostatic finite-element result can therefore be checked by both an integral of flux over a radial cross section and an integral of stored energy over the full material.
For \(a=10\) mm, \(b=30\) mm, \(h=8.0\) mm, \(N=80\) and \(\mu_r=1000\), the ideal small-signal inductance is \(11.25\) mH. The mean-radius estimate is \(10.24\) mH, about 9% below the exact result. At \(I=50\) mA the inner field is \(B(a)=0.0800\) T while the outer field is \(0.0267\) T. A fluxmeter reports the cross-sectional average, here \(0.0439\) T. It cannot on its own certify that the inner material stays below a specified knee on its magnetisation curve.
Put different materials at different radii
Suppose the radial region \(a<r<s\) has permeability \(\mu_1\) and the outer region \(s<r<b\) has \(\mu_2\), with neither material carrying a free interface current. The azimuthal \(\mathbf H\) is tangential to the material interface and remains continuous there as required. The tangential \(B\) may jump. Each material carries a parallel contribution to total flux:
The layers sit side by side across the cross section. Adding their reluctances in series would describe a different geometry, in which the same flux crosses successive materials along its path. For a uniform material the radius that divides the flux equally solves \(\ln(s/a)=\ln(b/s)\), so \(s=\sqrt{ab}\). In the 10–30 mm example this is 17.3 mm; half the flux occupies only 7.3 mm of the total radial thickness. Swapping a better and a poorer material between two equal-width radial bands therefore changes the measured inductance.
How a radial average can reveal a local material curve
Introduce \(X=NI/(2\pi)\). For one homogeneous reversible material the exact flux per height is
A terminal flux measurement samples a whole interval of magnetising field. The endpoints both move as current changes. Differentiating the last expression yields
Thus a family of flux readings relates the material values on the inner and outer edges. If the lower-field portion of the material curve has been calibrated independently, this relation can help infer higher-field response from the toroidal measurement.
This inverse calculation differentiates measured data, amplifying flux noise and any systematic drift. A preferable check on a proposed \(B(H)\) curve is often to integrate it forward across the annulus and compare directly with the flux measurements over multiple currents. Agreement at just one bias does not constrain the full material slope. A second toroid machined from the same material with a different ratio of outer to inner radius changes the radial weighting and provides an additional test.
Identify the first loss of linearity
A measured reversible \(B(H)\) curve follows the stated linear permeability until \(B=0.20\) T, after which its differential slope decreases. At what current does the first radial shell reach the knee? Derive the differential inductance above that current without assigning one uniform permeability to the whole core.
Derive the result and check it independently
The first shell is at \(a\). Solve \(\mu NI/(2\pi a)=0.20\) T, giving \(I=0.125\) A. Farther out the local field is still lower. In a nonlinear reversible material the exact flux linkage is \(Nh\int_a^b B[NI/(2\pi r)]\,dr\). Differentiate with respect to \(I\) at fixed geometry and obtain \(L_d=N^2h(2\pi)^{-1}\int_a^b [dB/dH]_{H(r)}dr/r\). The derivative falls progressively as a larger radial region samples the reduced material slope. A sharp knee in the local curve can therefore become a gradual bend in a terminal inductance measurement.
Integrate digitised \(B(H)\) over successively finer radial rings and compare the local slope result with a symmetric finite difference of the total flux linkage. Disagreement can indicate inadequate radial resolution right where the inner shell first enters the knee. If the material has hysteresis, specify the branch and excitation protocol before treating a measured small-signal slope as a reversible derivative.
Griffiths, 5th ed., §§6.3–6.4 and 7.2.3 · magnetic response and inductance
Specify the path taken by the field
A toroidal winding wraps a ring of magnetic material. Large permeability can guide flux around the ring. Cutting a small gap into it can greatly reduce inductance. To understand this change we need to distinguish the field produced by free current from the magnetic response of the material. Write \(\mathbf B=\mu_0(\mathbf H+\mathbf M)\), where \(\mathbf M\) is magnetic moment per unit volume. For a linear isotropic material,
The approximation of a single constant \(\mu_r\) requires operation below strong saturation and negligible hysteresis over the field excursion.
Treat the cross-section as narrow compared with the mean radius and assume tightly distributed turns. Let the material path length be \(\ell_c\), gap length \(g\) and common area \(A\). Neglect stray flux and fringing as a first approximation when the gap is short compared with the transverse dimensions. These choices reduce a spatially varying field to one representative flux through each cross-section. They do not imply equal values of \(H\) in the two materials.
Calculate a coil field without an assumed magnetic path
Ampère's circulation law simplifies when symmetry makes the field uniform along a useful closed path. For a circular wire loop in free space, symmetry does not supply such a path through its aperture. In vacuum a steady thin-wire current instead contributes according to Biot–Savart,
where \(\mathbf R\) points from the wire element to the observation point. The formula assumes a complete steady circuit. For a laboratory coil the distant return leads should contribute little to the region being observed.
Take a circular loop of radius \(a\) and observe on its axis at coordinate \(z\). All wire elements share distance \(\sqrt{a^2+z^2}\). Their transverse contributions cancel in opposite pairs. The axial component of \(d\boldsymbol\ell\times\mathbf R\) is \(a\,d\ell\), and \(\oint d\ell=2\pi a\). For \(N\) tightly spaced turns the sum yields
A 50-turn coil of radius 40.0 mm carrying 0.800 A produces 0.628 mT at the centre. One radius away the ratio is \(2^{-3/2}=0.354\), giving 0.222 mT. Far along the axis the field falls as the inverse cube and is proportional to the magnetic moment \(NI\pi a^2\). Such a falloff is absent from a lumped magnetic circuit with a single prescribed uniform field. Which model is appropriate depends on whether a core guides most of the flux or the winding produces a field through open space.
Practise on sheet 2 · Choose the separation of a uniform-field coil pair. Further reading · University of Cambridge · David Tong, Electromagnetism · §3.2.3 Biot-Savart Law.
Apply the two circulation and flux laws
Magnetic flux continuity follows from \(\nabla\cdot\mathbf B=0\). With negligible leakage, the same \(\Phi=BA\) crosses the core and the gap. Ampère’s law around the ring gives \(H_c\ell_c+H_g g=NI\) for \(N\) turns carrying current \(I\). Substitute \(H_c=B/(\mu_0\mu_r)\) and \(H_g=B/\mu_0\) to find
Each denominator contribution in the flux expression is called a reluctance. The sum follows from the distinct magnetic potential drops along one flux path. A gap as short as \(\ell_c/\mu_r\) accounts for half the total circulation even though it occupies only a small fraction of the length. For a ring of appreciable radial width, the ungapped toroidal field varies as \(1/r\) and flux should be integrated over the cross-section.
Link field energy to an electrical measurement
A coil’s flux linkage is \(N\Phi\) when each turn links the same flux. For a fixed, linear geometry \(L=N\Phi/I\). The voltage needed to raise the current is \(v=L\,dI/dt\) in the passive sign convention, omitting winding resistance. The power delivered to the magnetic field is \(vi\). Integrating as the current grows gives stored energy \(W=LI^2/2\). Equivalently, integrating \(B^2/(2\mu)\) over each region apportions this energy between the gap and the core.
Since the same \(B\) passes through both regions but their permeabilities differ, a unit volume of gap stores \(\mu_r\) times the energy of the same volume of core in this model. The ratio of total gap energy to total core energy is \(g\mu_r/\ell_c\). If permeability depends on field, a small-signal inductance measured around a bias is the derivative \(d(N\Phi)/dI\). It can differ from the ratio \(N\Phi/I\) inferred from a single point.
Estimate a coil with a machined gap
Choose \(N=100\), \(I=0.40\) A, \(\ell_c=0.20\) m, \(\mu_r=2000\), \(A=1.0\) cm² and \(g=0.50\) mm. The effective length in the field denominator is
Thus \(B=0.0838\) T, \(\Phi=8.38\) µWb and \(L=2.09\) mH. The gap contributes five sixths of the circulation and stores five sixths of the \(0.168\) mJ total energy.
Closing the gap at the same current would predict \(0.503\) T from the linear law. The calculation itself supplies a reason to consult the real material curve before accepting that number. A measured inductance that departs from the prediction may reflect core saturation, imperfect contact at the joint or fringing that changes the effective gap area. Measuring a small current sweep at several gap widths helps distinguish material response from the geometry of a single fixed gap.
The current-to-flux ratio and the incremental response need not agree near magnetic saturation. If \(\lambda\) is the linked flux, a slow voltage measurement detects \(d\lambda/dt=(d\lambda/dI)\dot I\), so small AC perturbations about a DC operating point report the local slope. In contrast, taking a single ratio \(\lambda/I\) effectively joins that point to the origin. The two are equal in the linear magnetic-circuit model derived above. Deliberately sweeping the bias provides an operational way to find where that model stops describing the core.
Two windings sharing a flux path
A second coil wound on the same magnetic core allows the flux model to predict mutual induction. Choose both positive winding directions so currents create flux around the core in the same sense. In a linear core of reluctance \(\mathcal R\) with negligible leakage, the magnetic flux is
Each turn links that same flux. Multiplying by the number of turns in winding 1 or 2 gives flux linkages \(\lambda_1,\lambda_2\), hence
Equality of the two mutual coefficients expresses reciprocity in this linear, stationary arrangement. With imperfect flux linkage one often writes \(M=k_c\sqrt{L_1L_2}\). The stored energy \(W=(L_1I_1^2+2MI_1I_2+L_2I_2^2)/2\) must be nonnegative for arbitrary currents, requiring \(|M|\le\sqrt{L_1L_2}\). In the perfectly coupled limit opposing ampere-turns can cancel the common core flux. Leakage and winding resistance then control the small residual voltages seen in real instruments.
Open the secondary so that \(I_2=0\). Faraday's law in the passive terminal-voltage convention gives
Their voltage ratio is the turns ratio, regardless of sinusoidal amplitude, provided winding drops are negligible. The input current still has to build the necessary flux. Inferring it requires the primary magnetizing inductance, which the turns ratio alone cannot supply.
Set a sinusoidal operating point
Use \(N_1=400\), \(N_2=100\), core area \(A=4.00\) cm² and linear reluctance \(\mathcal R=1.00\times10^6\) A/Wb. Then \(L_1=0.160\) H, \(L_2=0.0100\) H and \(M=0.0400\) H. Drive the primary with 8.00 V RMS at 100 Hz with secondary open. Integrating the sinusoidal voltage gives peak flux \(\Phi_{\rm pk}=\sqrt2V_{\rm rms}/(2\pi fN_1)=45.0\) μWb. The predicted peak flux density is \(0.113\) T, secondary voltage \(2.00\) V RMS and magnetizing current \(V_{\rm rms}/(2\pi fL_1)=79.6\) mA RMS.
At unchanged voltage but half the frequency, voltage ratio is unchanged while peak flux density and current double in this model. A measured current waveform that develops sharp peaks at low frequency can thus signal core saturation before any dramatic change in the nominal turns ratio. A fixed DC terminal voltage on an ideal resistance-free winding would instead keep changing the flux in time, outside the assumed sinusoidal operating condition.
A short electrical pulse can determine the sense of the windings before a sinusoidal test. Mark one terminal on each coil and increase primary current through the first marked terminal. The sign of the measured open-secondary pulse with respect to its marked terminal identifies whether the two positive winding conventions reinforce or oppose one another. Reversing one winding changes the sign of the mutual coefficient and of that pulse but leaves both self-inductances and the magnitude of the voltage ratio unchanged. A sign convention overlooked here becomes important when combining two coils in series, because their mutual induced voltages can either add or subtract.
Winding resistance also introduces voltage even at steady current, so a four-wire resistance measurement helps separate ohmic voltage from linkage changes during a slow pulse.
When does an air gap dominate a magnetic circuit?
A 0.25 m core with uniform cross-section carries 100 ampere-turns. In the linear, negligible-leakage model, the core and air gap share the same \(B\). Their magnetomotive drops add, giving \(B=\mu_0NI/(\ell/\mu_r+g)\).

Read values from the plot
| Air gap (mm) | Core μᵣ = 400 | Core μᵣ = 1000 | Core μᵣ = 2000 |
|---|---|---|---|
| 0 | 0.20106 | 0.50265 | 1.0053 |
| 0.5 | 0.1117 | 0.16755 | 0.20106 |
| 1 | 0.077332 | 0.10053 | 0.1117 |
| 1.5 | 0.059136 | 0.071808 | 0.077332 |
| 2 | 0.047872 | 0.055851 | 0.059136 |
Develop this calculation further
Chapter 17 · From a measured current to its magnetic field · Chapter 19 · How a magnet produces an exterior field
Study the full derivation
Interfaces, demagnetising fields and the work of magnetisation · Magnetism, induction and field dynamics
Two samples made of the same material can respond very differently to an externally applied field if one is a long rod and the other is a thin disc. The induced moment depends on the internal field, which the magnetised sample helps create. The same distinction reappears when one tries to infer a force from stored magnetic energy.