Fundamentals / Mechanical engineering / Engineering thermodynamics and heat transfer

Steady conduction, thermal resistance and insulation

Derive the heat leak through a cylindrical wall and identify when increasing insulation thickness can increase heat transfer.

From first principles

Derive series thermal resistance from conservation of heat rate

Consider conduction along a prescribed path through a stationary material, with local area \(A(x)\) normal to the heat flow and conductivity \(k(x)>0\). Assume a one-dimensional steady state, no side losses and no heat generation. A balance on an elementary slice gives a single heat rate \(\dot Q\) at every position. Fourier's measured constitutive relation links that heat rate to the temperature gradient:

\[\frac{d\dot Q}{dx}=0,\]
\[\dot Q=-k(x)A(x)\frac{dT}{dx}.\]

Separate variables and integrate from the hot to the cold surface. An exterior fluid film described by \(\dot Q=h A_s(T_s-T_\infty)\) introduces an additional drop proportional to the same heat rate:

\[T_{\rm hot}-T_\infty=\dot Q\left[\int_{\rm solid}\frac{dx}{k(x)A(x)}+\frac{1}{h A_s}\right].\]

The bracket is a thermal resistance in K/W. For a plane homogeneous layer it gives \(L/(kA)\); for radial conduction in a cylinder the local area \(2\pi rL\) varies, giving a logarithm. Adding resistances is justified by a common heat rate. Heat-generating layers or side branches require a separate balance before using a series formula.

Derivation and applications

How the changing area sets resistance in a spherical shell

Heat passing through the insulation of a spherical vessel spreads over a larger surface as it travels outward. Treat an inner surface at radius \(r_i\) as isothermal, a concentric outer radius \(r_o\), constant thermal conductivity \(k\), and uniform outside convection coefficient \(h\). Assume steady radial conduction with no internal heat generation, perfect interfaces and a uniform ambient temperature \(T_\infty\). With no accumulation between concentric spheres, the heat rate is constant even though local heat flux decreases outward.

Fourier’s empirical law specifies flux from temperature gradient. Multiply it by the local area and rearrange so that each radial slice contributes its own temperature drop:

\[\dot Q=-4\pi r^2 k\,dT/dr,\]
\[T_i-T_o=\frac{\dot Q}{4\pi k}\int_{r_i}^{r_o}\frac{dr}{r^2}.\]

The outer convective drop equals the same heat rate divided by the outer film conductance. Adding both drops gives a series relation:

\[\frac{T_i-T_\infty}{\dot Q}=R=\frac{1}{4\pi k}\!\left(\frac1{r_i}-\frac1{r_o}\right)+\frac1{4\pi h r_o^2}.\]

Increasing \(r_o\) adds conduction resistance but also raises film area. The sign of the derivative decides which effect dominates:

\[\frac{dR}{dr_o}=\frac{1}{4\pi k r_o^2}-\frac{2}{4\pi h r_o^3},\]
\[r_{\rm critical}=2k/h .\]

For an initially smaller radius, adding a thin layer can reduce total resistance; after this minimum the resistance grows. The result presumes fixed \(h\) and surface temperature \(T_i\). If changes in geometry substantially change natural convection or radiation, the assumed film law must be revisited.

Worked example

Evaluate an insulated sensor bead

Take \(r_i=3.00\) mm, \(r_o=6.00\) mm, \(k=0.0400\) W/(m K) and \(h=10.0\) W/(m² K). The shell contributes \(331.6\) K/W and the film \(221.0\) K/W. A \(40.0\) K inner-to-ambient difference gives \(0.0724\) W. The uncoated bead had outer resistance \(884\) K/W and lost only \(0.0452\) W. At \(6\) mm the coating is still below the \(8.00\) mm critical radius.

Second application

Determine whether a change in airflow reverses the trend

With forced airflow raising \(h\) to \(40.0\) W/(m² K), the critical radius falls to \(2.00\) mm, inside the bare bead. The bare and coated resistances become \(221\) and \(331.6+55.3=386.9\) K/W. The coating now reduces heat loss from \(0.181\) to \(0.103\) W. The same layer can change the sign of its effect because the surrounding film is part of the experiment.

Try it · Spherical insulation

Set the inputs to the values in the worked example, then vary one quantity while holding the others fixed. Compare the curve and numerical balance with the second application. The calculation uses the assumptions derived above; its readout identifies bounds such as choking, phase-region changes and inconsistent measurements.

Turn heat flux into a temperature field

Energy moves through a stationary homogeneous solid down its temperature gradient. For isotropic conduction Fourier’s law is

\[\mathbf q=-k\nabla T,\]

where \(\mathbf q\) is heat flux in W/m² and \(k\) is thermal conductivity. A steady one-dimensional wall with no internal heat generation passes the same heat rate at every cut. Heat flux is uniform only when the area of the cuts is uniform. That distinction matters for pipes and spherical shells.

Let an inner cylindrical surface at radius \(r_i\) be warmer than the outer one at \(r_o\). Assume a long concentric wall of length \(L\), constant \(k\), negligible end loss and axisymmetry. Fourier’s law gives

\[\dot Q=-2\pi rLk\,dT/dr,\]

with outward rate taken positive. The area grows with radius, so the magnitude of \(dT/dr\) decreases outward even though the heat rate is unchanged.

Derive and combine thermal resistances

Separate and integrate over the cylindrical wall. This yields

\[T_i-T_o=\dot Q\ln(r_o/r_i)/(2\pi k L).\]

The cylindrical conduction resistance is the factor multiplying \(\dot Q\). At an outer convection boundary \(\dot Q=h\,2\pi r_oL(T_o-T_\infty)\), giving another resistance between the surface and the bulk surroundings. For a prescribed inner surface temperature,

\[\dot Q=\frac{T_i-T_\infty}{\ln(r_o/r_i)/(2\pi kL)+1/(2\pi r_oLh)}.\]

For multiple concentric layers, add the conduction resistance of each. The drops across series resistances sum because the same rate passes through them all. Poor contact between layers can add another temperature jump. A parallel heat leak bypassing the insulation carries part of the total heat under a common temperature difference, so its conductance adds instead.

Estimate the heat leak from a warm pipe

Take \(L=1.0\) m, \(r_i=0.020\) m and \(r_o=0.040\) m. The insulation has \(k=0.050\) W/(m K) and the surroundings have \(h=10\) W/(m² K), \(T_\infty=293\) K. The inner insulation surface is held at 353 K. The conduction resistance is \(\ln2/[2\pi(0.050)(1)]=2.206\) K/W, and the outer film resistance is

\[1/[10(2\pi)(0.040)(1)]=0.398\,\mathrm{K/W}.\]

Total heat loss is \(60/(2.206+0.398)=23.0\) W per metre of pipe.

The outer surface is

\[293+(23.0)(0.398)=302.2\,\mathrm{K}.\]

The rest of the 60 K difference is within the insulation. The heat flux at the outer surface is half that at the inner surface, because the heat-transfer area is twice as large. Assigning the outer circumference to the entire wall in a flat-wall formula would miss this variation. When thickness is very small relative to radius, expanding the logarithm recovers the plane-wall approximation.

Explain the critical radius

Increasing \(r_o\) makes the conduction resistance grow but makes the convection resistance shrink. At fixed \(T_i,T_\infty,h,k\), differentiating the total resistance gives

\[dR/dr_o=1/(2\pi Lk r_o)-1/(2\pi Lh r_o^2).\]

Its minimum occurs at \(r_c=k/h\); that radius maximises heat loss. Here \(r_c=0.0050\) m, already below the bare pipe radius, so adding this insulation reduces loss from the outset. A much thinner wire could initially lose more heat because its exposed area increases faster than the wall resistance. This conclusion assumes the same external coefficient as the diameter changes. If natural convection or radiation changes appreciably, the boundary model and its temperature dependence must be reconsidered.

Recover an unknown contact resistance

A 0.010 m² test sandwich passes 8 W at steady state between measured outer face temperatures of 50 and 40 °C. Its measured total resistance is

\[10/8=1.25\,\mathrm{K/W}.\]

The two known solid layers together account for 0.75 K/W, leaving 0.50 K/W attributable to the interface if other parasitic paths are small. The area-normalised contact resistance is \(R''=A R=0.0050\,\mathrm{m^2K/W}\), corresponding to conductance \(1/R''=200\,\mathrm{W/(m^2K)}\). A pair of thermocouples on opposite sides of the interface should then show a 4 K temperature difference. That independent measurement helps distinguish contact resistance from an unaccounted external heat loss.

Derive the temperature field along a cooling fin

A fin adds area for convection but must first conduct heat from its base to that area. Treat a straight fin with constant cross-sectional area \(A_c\), exposed perimeter \(P\), conductivity \(k\) and uniform film coefficient \(h\). Its base is held at \(T_b\) and surrounding air at \(T_\infty\). Assume the temperature is nearly uniform across each fin section; a small transverse Biot number supports this approximation. Take the tip as adiabatic, appropriate when tip area is small or insulated. Define excess temperature \(\theta=T-T_\infty\).

A slice \(dx\) loses heat \(hP\theta\,dx\) to convection. Its decrease in axial heat rate must supply that loss. Fourier’s law \(Q_x=-kA_c\,d\theta/dx\) then yields \(\theta''-m^2\theta=0\), where \(m=\sqrt{hP/(kA_c)}\). The boundary conditions are

\[\theta(0)=\theta_b,\ \theta'(L)=0.\]

Using a hyperbolic cosine referenced to the insulated end gives

\[\theta(x)=\theta_b\frac{\cosh[m(L-x)]}{\cosh(mL)},\]
\[Q_b=\sqrt{hPkA_c}\,\theta_b\tanh(mL).\]

If the whole fin stayed at base temperature, heat removal would be \(hPL\theta_b\). The ratio \(\eta_f=\tanh(mL)/(mL)\) is the fin efficiency under the stated tip model. A very long fin can have low efficiency although it removes more heat than a short one; efficiency measures use of installed area, while total heat removal measures cooling duty.

Decide whether doubling fin length is worthwhile

An aluminium fin has rectangular section 20 mm by 2 mm, length 50 mm and conductivity 180 W/(m K). Air at 25 °C flows over it with \(h=35\,\mathrm{W/(m^2K)}\), and the base is at 75 °C. Thus

\[A_c=4.0\times10^{-5}\,\mathrm{m^2},\ P=0.044\,\mathrm m,\ \theta_b=50\,\mathrm K.\]

The transverse length \(A_c/P=0.909\,\mathrm{mm}\) gives \(hA_c/(kP)=0.000177\), consistent with small cross-sectional gradients. The fin parameter is \(m=\sqrt{35(0.044)/[180(4\times10^{-5})]}=14.6\,\mathrm{m^{-1}}\); hence \(mL=0.731\) and \(\tanh(mL)=0.624\).

The base heat rate is

\[\sqrt{35(0.044)(180)(4\times10^{-5})}(50)(0.624)=3.29\,\mathrm W.\]

Fin efficiency is

\[0.624/0.731=0.854.\]

Doubling length makes \(mL=1.46\) and raises heat removal to about \(5.27\tanh(1.46)=4.73\,\mathrm W\). Twice the material therefore gives only 44% more cooling. The original covered base area by itself would convect \(35(4\times10^{-5})(50)=0.070\,\mathrm W\), so the fin still offers a large improvement. Adding several fins can change the film coefficient through crowding, and finite contact resistance can lower the effective base temperature. Those effects must be checked before multiplying a single-fin heat rate by the number installed.

A surface thermometer offers a second way to test the heat-transfer model. The insulated-tip solution gives

\[T(L)=25+50/\cosh(0.731)=64.1^\circ\mathrm C.\]

If a thin thermocouple instead measures nearly 75 °C all along a fin while the base still sheds only the predicted few watts, the effective film coefficient may be smaller than assumed. A much colder measured tip could indicate strong local tip convection or poor base contact. Interpret a profile together with the base heat rate: several combinations of conductance, base temperature and film conditions can reproduce one measured temperature, but they need not reproduce both the profile and the total cooling duty.

The root of the fin offers a particularly direct simultaneous measurement of axial temperature gradient and supplied heat rate.

Infer wall cooling from a measured skin-friction force

The film coefficient in a thermal-resistance calculation carries information about transport within the flow. For a smooth isothermal plate, take a steady parallel free stream of speed \(U\) and temperature \(T_e\). Define \(\theta=(T-T_w)/(T_e-T_w)\). Both \(u/U\) and \(\theta\) rise from zero at the wall to one in the outer stream. If momentum and heat diffuse at equal rates, their transport equations and boundary conditions match for a constant-property, zero-pressure-gradient boundary layer starting at the same leading edge. Under this approximation their profiles and their normalized wall gradients coincide. In turbulent flow the analogy additionally relies on similar turbulent diffusivities.

For a wall hotter than the stream the heat flux into the fluid and the magnitude of skin friction are \(q''=k(T_w-T_e)\partial_y\theta|_w\) and \(\tau_w=\mu U\partial_y(u/U)|_w\). Divide the equations. At \(Pr=\mu c_p/k=1\), the unknown gradient cancels. With \(q''=h(T_w-T_e)\) the Reynolds analogy becomes

\[h\simeq\frac{c_p\tau_w}{U},\]
\[St=\frac{h}{\rho Uc_p}\simeq \frac{C_f}{2},\]
\[C_f=\frac{\tau_w}{\tfrac12\rho U^2}.\]

A small heat-transfer tunnel has effective \(Pr\) close to one. At \(U=10.0\,\mathrm{m\,s^{-1}}\), the stream has \(\rho=1.20\,\mathrm{kg\,m^{-3}}\) and \(c_p=1000\,\mathrm{J\,kg^{-1}K^{-1}}\). A force balance isolates the skin friction on one flush plate face of area \(0.50\,\mathrm{m^2}\), and measures \(0.180\,\mathrm N\). The mean shear is \(0.360\,\mathrm{Pa}\), hence \(\bar C_f=0.00600\) and \(\bar h\simeq36.0\,\mathrm{W\,m^{-2}K^{-1}}\). A uniform wall 20 K above the stream loses approximately \(36(0.50)(20)=360\,\mathrm W\) by convection. Average drag produces an average coefficient because both quantities are integrated over the same face. Pressure drag from a protruding instrument, an unheated entry length or a fluid with a very different Prandtl number would invalidate that identification.

Practise on sheet 3 · How much skin friction is consistent with a cooling requirement?. Further reading · MIT · 16.Unified Thermodynamics and Propulsion · §17.1 The Reynolds Analogy.

Can adding insulation initially increase heat loss?

A long wire of radius 2 mm is held 50 K above ambient. Insulation of conductivity 0.08 W/(m K) adds radial resistance but increases exterior convection area. Add cylindrical conduction and convection resistances per unit length before converting back to heat rate.

Can adding insulation initially increase heat loss?. Horizontal axis: Outer radius of insulation (mm). Vertical axis: Heat loss per length (W/m). Data follow the figure.
At h = 8 W/(m² K) heat loss peaks at the critical radius k/h = 10 mm; at h = 32 it peaks at 2.5 mm. This effect assumes constant surface film coefficient and prescribed inner temperature. A fixed-power heater poses a different question.
Read values from the plot
Heat loss per length (W/m) at selected values of Outer radius of insulation (mm).
Outer radius of insulation (mm)Outer film h = 8 W/(m² K)Outer film h = 16 W/(m² K)Outer film h = 32 W/(m² K)
25.026510.05320.106
7.7049.496212.58115.022
13.59.48311.02411.998
19.2969.02439.950110.488
258.59039.22069.5717

Download all 251 plotted samples (CSV)

Interactive calculation · change the inputs of this example

Raise the film coefficient until the critical radius falls below the wire radius. Check whether adding insulation can still increase heat loss.

The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.

Study the full derivation

How a gravity-drained condensate film limits heat transfer · Thermal processes and transport in engineering

Saturated vapour condenses on a cool vertical plate. A liquid film thickens as it drains, adding thermal resistance toward the bottom. Derive the local heat-transfer coefficient from coupled momentum and energy balances, then determine which observations would invalidate the smooth-film model.