To reproduce the case, put its notebook and accompanying inputs in the same folder. Use the Python environment set up in the installation tutorial. Start with the original parameters and compare the result with the check reported below.
Run this example yourself. The OneSimulation Runtime brings the full Python library and an MCP server for Codex and Claude Code. It starts with a seven-day trial, then from €19 per month before any applicable tax.

What it computes
OneSimulation solves two advection-diffusion channels coupled through a wall conductance by a partitioned fixed-point iteration between the streams. The geometry is read from a STEP file with named faces; the script that builds it comes with the notebook.
What it checks
Outlet temperatures are within about 0.3 % of the inlet difference; the effectiveness and the exponential bulk profiles match the counterflow NTU solution.
Geometry
The notebook starts at the import of the CAD file counterflow_heat_exchanger_ntu.step: STEP (AP242), readable by any CAD program, with the names of the faces that the boundary conditions use. Put it next to the notebook.

The geometry script
The script counterflow_heat_exchanger_ntu_geometry.py builds the geometry with the CAD objects of OneSimulation and writes the file. Change a dimension there, run it, and run the notebook again.
"""Geometry of the OneSimulation example "Counterflow heat exchanger".
Builds one channel of the exchanger, 45 mm long with a 1 mm gap (along y) and 2 mm width (along z),
with the CAD objects of OneSimulation and writes counterflow_heat_exchanger_ntu.step. Both streams
use this channel. The faces keep their names x_min, x_max, y_min, y_max, z_min and z_max in the
file; the two faces across the width form the group ends.
"""
from onesim.cad.d3 import Box
duct = Box(length=0.045, width=1.0e-3, height=2.0e-3)
faces = duct.boundaries
duct = duct.grouped(ends=faces.z_min | faces.z_max)
duct.save("counterflow_heat_exchanger_ntu.step")The notebook
The complete notebook, cell by cell. Run it to produce the figures and the comparison printout.
Two water streams flow in opposite directions through parallel channels (1 mm gap, 2 mm wide, 45 mm long) separated by a 1.2 mm polypropylene wall. Heat crosses the wall from the hot to the cold stream; the outer faces are insulated. Each channel obeys
and exchanges the heat flux \(h_w\,(T_h-T_c)\) with the other one through the wall conductance \(h_w=k_w/t_w\).
Both streams use the channel from the CAD file counterflow_heat_exchanger_ntu.step with the faces x_min and x_max (the two ends), y_min and y_max (across the gap) and the group ends across the width. The script counterflow_heat_exchanger_ntu_geometry.py builds it with the CAD objects of OneSimulation.
Reference. With the capacity rates \(C=\rho c_p u\,t\,w\) of the two streams, \(C_r=C_\min/C_\max\) and \(\mathrm{NTU}=UA/C_\min\), the effectiveness of a counterflow exchanger is
and the temperature difference between the streams decays as \(e^{-mx}\) with \(m=Uw\,(1/C_h-1/C_c)\). The overall coefficient combines the wall with the two fluid films, \(1/U=t_w/k_w+2t/(3k_f)\).
import numpy as np
from onesim.cad.d2 import Plane
from onesim.cad.exchange import load
from onesim.materials import IsotropicSolid
from onesim.meshing import StructuredHexahedralMesher
from onesim.numerics import Numerics
from onesim.numerics.fem import FiniteElement, GalerkinAdvection, Lagrange
from onesim.numerics.linear import SparseDirect
from onesim.physics.heat_transfer import (
ConvectiveHeatFlux,
ConvectiveHeatTransfer,
FixedTemperature,
HeatFlux,
)
from onesim.results.integration import mean_value
from onesim.simulation import Problem, Simulation
from onesim.visualization import plots, theme
theme.set()Geometry and mesh
One quadratic element across the gap and 80 along the flow.
duct = load("counterflow_heat_exchanger_ntu.step")
faces = duct.boundaries
length, gap, width = duct.size
mesh = StructuredHexahedralMesher(cells=(80, 1, 1)).generate(duct)
fig = plots.figure(1, 2, size=(14, 4.5))
plots.geometry(
duct,
selection={"wall to the cold stream": faces.y_max, "hot inlet": faces.x_min},
labels=False,
title="Channel of the hot stream",
ax=fig[0],
)
plots.mesh(
mesh, groups=("all",), legend=False, title=f"{mesh.cell_count} hexahedra", ax=fig[1]
)
plots.show()Model
solve computes one stream for a given wall temperature of the other stream. The two streams are solved in turn until the temperatures settle.
water = IsotropicSolid(
density=1000.0,
specific_heat_capacity=4180.0,
thermal_conductivity=0.6,
youngs_modulus=2e9,
poisson_ratio=0.3,
thermal_expansion_coefficient=1e-5,
)
wall_conductance = 0.12 / 1.2e-3
hot_inlet, cold_inlet, ntu, capacity_ratio = 350.0, 290.0, 1.5, 0.6
overall = 1 / (1 / wall_conductance + 2 * gap / (3 * water.thermal_conductivity))
hot_capacity = overall * length * width / ntu
cold_capacity = hot_capacity / capacity_ratio
speed = lambda capacity: capacity / (
water.density * water.specific_heat_capacity * gap * width
)
numerics = Numerics(
spatial=FiniteElement(element=Lagrange(order=2), convection=GalerkinAdvection()),
linear_solver=SparseDirect(),
)
def solve(velocity, inlet, outlet, wall, outer, inlet_temperature, other_stream):
"""Temperature of one stream; `other_stream(x)` is the wall temperature of the other one."""
model = ConvectiveHeatTransfer(
domain=duct.volume, material=water, velocity=(velocity, 0.0, 0.0)
)
problem = Problem(
name="Exchanger channel",
geometry=duct,
physics=(model,),
boundary_conditions=(
FixedTemperature(boundary=inlet, physics=model, value=inlet_temperature),
HeatFlux(boundary=outlet | outer | faces.ends, physics=model, value=0.0),
ConvectiveHeatFlux(
boundary=wall,
physics=model,
heat_transfer_coefficient=wall_conductance,
ambient_temperature=other_stream,
),
),
)
return (
Simulation(problem=problem, mesh=mesh, numerics=numerics)
.solve_stationary()
.field(model.temperature)
)
def at_wall(field, y):
"""Temperature of a stream on its wall face as a function of x."""
return lambda x: field.evaluate(
np.column_stack(
(np.ravel(x), np.full(np.size(x), y), np.full(np.size(x), width / 2))
)
).reshape(np.shape(x))
cold_wall = lambda x: cold_inlet + 0.0 * np.asarray(x)
for sweep in range(12):
hot = solve(
speed(hot_capacity),
faces.x_min,
faces.x_max,
faces.y_max,
faces.y_min,
hot_inlet,
cold_wall,
)
cold = solve(
-speed(cold_capacity),
faces.x_max,
faces.x_min,
faces.y_min,
faces.y_max,
cold_inlet,
at_wall(hot, gap),
)
cold_wall = at_wall(cold, 0.0)Results
The bulk temperature of each stream is its mean over the channel cross-section. The effectiveness-NTU solution gives the heat flow, the decay rate \(m\) and from them both bulk temperatures along the exchanger.
x = length * np.linspace(1e-6, 1 - 1e-6, 31)
hot_bulk, cold_bulk = (
np.array(
[
mean_value(field, plane=Plane(origin=(position, 0, 0), normal=(1, 0, 0)))
for position in x
]
)
for field in (hot, cold)
)
decay = np.exp(-ntu * (1 - capacity_ratio))
effectiveness = (1 - decay) / (1 - capacity_ratio * decay)
m = overall * width * (1 / hot_capacity - 1 / cold_capacity)
difference = (
hot_inlet
- cold_inlet
- effectiveness * hot_capacity / cold_capacity * (hot_inlet - cold_inlet)
)
hot_exact = (
hot_inlet - overall * width / hot_capacity * difference * (1 - np.exp(-m * x)) / m
)
cold_exact = hot_exact - difference * np.exp(-m * x)
power = hot_capacity * (hot_inlet - hot_bulk[-1])
print(
f"hot outlet simulation {hot_bulk[-1]:.2f} K effectiveness-NTU {hot_exact[-1]:.2f} K"
)
print(
f"cold outlet simulation {cold_bulk[0]:.2f} K effectiveness-NTU {cold_exact[0]:.2f} K"
)
print(
f"effectiveness simulation {power / (hot_capacity * (hot_inlet - cold_inlet)):.4f} effectiveness-NTU {effectiveness:.4f}"
)
print(
f"heat given off by the hot stream {power:.4f} W, taken up by the cold stream "
f"{cold_capacity * (cold_bulk[0] - cold_inlet):.4f} W"
)Figure
plots.line(
1e3 * x,
points={
"hot stream (flows to the right)": hot_bulk,
"cold stream (flows to the left)": cold_bulk,
},
reference={
"hot stream (flows to the right)": hot_exact,
"cold stream (flows to the left)": cold_exact,
},
xlabel="position along the exchanger [mm]",
ylabel="bulk temperature [K]",
legend="upper right",
title="Counterflow heat exchanger: simulation (markers) and effectiveness-NTU (dashed)",
)
plots.show()Going further
Make the two capacity rates equal: the temperature difference is then uniform and both profiles become straight lines. Reverse the cold stream to obtain a parallel-flow exchanger, whose effectiveness is lower at the same NTU. Lengthen the channel in counterflow_heat_exchanger_ntu_geometry.py and write the STEP file again to raise the NTU.