Chapter 1 · Velocity fields, flow rates and conservation of mass
Read local acceleration from a velocity field and use an integral mass balance to connect inlet, outlet and storage.
From first principles
Derive the continuity equation from conservation of mass
Choose a fixed region of space containing fluid of density \(\rho(\mathbf x,t)\) and velocity \(\mathbf u(\mathbf x,t)\). Mass crosses a small boundary element \(dA\) with outward normal \(\mathbf n\) at the signed rate \(\rho\mathbf u\cdot\mathbf n\,dA\). A positive flux removes mass. With no sources of mass inside, the rate of change of the enclosed mass must balance the net outflow.
For a stationary control volume the time derivative can be taken inside the integral. The divergence theorem changes the boundary integral to a volume integral. Since the resulting balance holds for every sufficiently small volume in a smooth flow, its integrand must vanish.
Here \(D/Dt=\partial_t+\mathbf u\cdot\nabla\) follows a moving parcel. Constant parcel density therefore gives
In a steady single-inlet, single-outlet incompressible duct, integration reduces this statement to \(A_1\bar u_1=A_2\bar u_2\).
Background · Material acceleration
A fluid parcel can accelerate as it follows a steady but spatially varying velocity. A probe fixed in space measures only the local time history.
Derivation and applications
Distinguish a parcel trajectory from an instantaneous streamline
Dye introduced into an unsteady flow need not follow a line drawn tangent to one velocity snapshot. To calculate the difference, consider a spatially uniform planar velocity field with horizontal component \(u=U>0\) and vertical component \(v=at\), where \(a\) is constant. Such a field is divergence-free because neither component varies with position. Neglect diffusion and assume a neutrally buoyant tracer. A parcel released at the origin at time \(t_0\) obeys the two ordinary differential equations
Eliminate the elapsed time to find the parcel path. The first term reflects vertical velocity at release and the quadratic term accumulates the subsequent acceleration. In contrast, an instantaneous streamline uses the velocity direction at one frozen time \(t_s\) for all its points.
Continuous injection at the origin generates a third observable. At a fixed observing time \(t_s\), different coloured parcels have different release times \(t_0=t_s-x/U\). Substitution into the position solution gives the locus of all visible dye at that instant, called the streakline.
The streakline is tangent to the instantaneous velocity at the injector but curves away from that direction farther downstream. In the steady limit \(a=0\) all three constructions produce horizontal lines.
Worked example
Compare a pulse of dye with a velocity image
Take \(U=0.400\) m/s and \(a=0.100\) m/s². A parcel released at \(t_0=0\) reaches \(x=0.800\) m at 2.00 s and has risen \(\tfrac12(0.100)(2.00)^2=0.200\) m. The streamline through the injector at 2.00 s has slope 0.500, reaching 0.400 m at the same horizontal coordinate. It represents the current velocity field, which changed while the pulse was travelling.
Change the inputs and inspect this calculation below
Second application
Recover acceleration from a continuous dye trace
In another experiment \(U=0.500\) m/s. At \(t_s=3.00\) s, continuously injected dye at \(x=0.500\) m lies 0.250 m above the source. That parcel is 1.00 s old, so its release time was 2.00 s. From \(y=a(3^2-2^2)/2\) one finds \(a=0.100\) m/s². The local velocity slope at observation is then 0.600, independently measurable from a short-exposure particle image.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Look at a point or follow a parcel
At a contraction in an otherwise steady pipe, a parcel of water speeds up. A probe fixed at the throat reports a constant speed throughout the experiment. Both observations are compatible because a field can vary along the path even when it has no explicit time dependence. Eulerian measurements describe velocity at a place. Following a marked parcel gives its changing position and velocity.
Write the velocity field as \(\mathbf u(\mathbf x,t)\). During \(dt\) the parcel advances through \(d\mathbf x=\mathbf u\,dt\). The chain rule along that trajectory gives
The first term is local acceleration and the second is convective acceleration. In steady one-dimensional flow \(a_x=u\,du/dx\). A streamline is tangent to the instantaneous velocity. In a steady flow pathlines and streamlines coincide, whereas in an unsteady field the curve traced by a parcel can differ from a single snapshot’s streamlines.
Background · Can a sequence of photographs identify the acceleration of one parcel?
A fixed camera that records velocity at one pixel measures an Eulerian history. A particle may enter a different pixel long before the next frame. For the planar velocity field \(\mathbf u=(a x,-a y)\) with constant \(a\), all fixed pixels record an unchanging field. A parcel released on the positive \(x\) axis instead obeys \(x(t)=x_0e^{at}\).
At \(a=2~\mathrm{s}^{-1}\) and \(x=0.10\) m on the axis, the downstream acceleration is 0.40 m/s². The parcel moves into faster neighbouring fluid. Estimating acceleration from an image pair therefore requires either tracking the same particle or combining the local time difference with spatial velocity gradients.
Count the mass crossing a surface
Enclose part of a fluid system in a fixed control volume. A small surface element with outward normal \(\mathbf n\) passes volume \((\mathbf u\cdot\mathbf n)dA\,dt\) in time \(dt\). Multiply by density and add over the whole boundary. Normal inflow is negative, reducing the net outward flux. Conservation of mass is
In steady operation the mass flow rate entering all inlets equals that leaving all outlets. A one-inlet, one-outlet reduction with uniform cross-sectional density gives
The mean velocity is the area integral of the normal component divided by area. A centreline speed is seldom that mean. For variable density the volume rate can change along a duct while mass rate remains constant.
Accelerate water in a contraction
Water of density 1000 kg/m³ enters a straight circular nozzle 60 mm in diameter with a mean speed of 1.50 m/s. The outlet is 30 mm in diameter. First use the inlet area to find the volume and mass passing per second.
For steady incompressible flow the same volume per second must pass through an outlet of one quarter the inlet area. The mean speed increases accordingly.
These speeds determine the change in streamwise momentum flux if both profiles are nearly uniform. The pressure and wall forces responsible for that change require a momentum balance.
Suppose along a centreline segment of length 0.30 m the speed is approximately linear from 1.50 to 6.0 m/s. Its gradient is 15 s⁻¹. At a local speed of 3.0 m/s the convective acceleration is 45 m/s². The transit time through the segment is
Dividing distance by the arithmetic mean of the two speeds gives a different answer because a particle spends a larger fraction of its time in the slower region.
Let the control volume fill
A vented tank receives 4 L/s and initially delivers 2 L/s through a controlled outlet. In a constant horizontal tank section of 0.50 m² the water level rises at \((0.004-0.002)/0.50=0.0040\) m/s. The storage term remains essential even if both inlet and outlet flow meters have steady readings. A free-surface tank can therefore act as an independent calibration: the measured volume increase over a timed interval should equal the integrated difference between inflow and outflow. If the outlet is driven by the changing hydrostatic head, its rate will cease to be constant and the balance becomes a differential equation for the depth.
Check continuity directly in a velocity field
A planar test field \(u=ax,\ v=-ay\) with constant \(a\) stretches a fluid square in one direction and shortens it in the other. Since \(\partial_xu+\partial_yv=a-a=0\), its area is preserved locally. A particle released at \(x_0,y_0\) follows \(x=x_0e^{at},\ y=y_0e^{-at}\); the product \(xy\) remains constant. This explicit trajectory shows how an incompressible parcel can deform and accelerate even when the velocity at every fixed point is independent of time.
Count mass through a control surface that moves
A flow meter on a translating piston does not see the same volume rate as a stationary meter at the same instant. Start with a material system, whose total mass is constant. Over a short time \(dt\), a patch of control surface of area \(dA\) moves a distance \(\mathbf v_s\cdot\mathbf n\,dt\) in its outward normal direction. Fluid moves a distance \(\mathbf v\cdot\mathbf n\,dt\) in that direction. The volume swept through the moving patch is the difference times \(dA\). Converting this volume into mass gives the moving-control-volume form of continuity:
The storage term differentiates the mass inside the actual changing volume. A boundary following a parcel has zero relative normal velocity there, even when the parcel and the boundary move quickly in the laboratory. On an impermeable wall this no-penetration condition applies to its normal movement; the mass balance alone imposes no constraint on tangential slip. Setting \(\mathbf v_s=0\) recovers the fixed-volume formula. Making the entire surface material removes the flux term and recovers conservation of the system mass.
For constant density, differentiating the geometric volume and using the outward convention gives
Substitution shows how the familiar \(\int\mathbf v\cdot\mathbf n\,dA=0\) can hold for an instantaneous surface even while its enclosed volume is growing. Relative flux and volume storage must be paired consistently.
Interpret a flow reading on a moving piston
A horizontal cylinder of area \(0.010\,\mathrm{m^2}\) has an inlet in its fixed left end and a small outlet passing through a piston at its right end. The piston moves to the right at 0.040 m/s while the cylinder stays full of incompressible water. A fixed inlet meter measures \(0.00070\,\mathrm{m^3/s}\). The volume occupied by water grows at \(0.010(0.040)=0.00040\,\mathrm{m^3/s}\). Therefore the relative outlet flux through the piston is \(0.00070-0.00040=0.00030\,\mathrm{m^3/s}\), or 0.30 L/s.
The outlet area is \(2.0\times10^{-4}\,\mathrm{m^2}\) and flow exits to the right. Its mean velocity relative to the piston is 1.50 m/s, while its laboratory velocity at the moving outlet is
Multiplying that laboratory velocity directly by the outlet area gives 0.308 L/s, too high for the outlet flow measured by an instrument carried on the piston. If the piston moved to the right at 0.070 m/s, the entire inlet rate would fill the new volume and relative outlet discharge would be zero. These conclusions assume no leakage past the piston rim and that the outlet area is part of the moving boundary; a fixed downstream collection nozzle would require its own control surface and storage terms.
A downstream weighing tank that travels with the piston would collect 0.30 kg per second at water density 1000 kg/m³. This is the discharge relative to that apparatus. The distinction is measurable and does not depend on any pressure-loss assumption for the outlet.
Can a steady flow accelerate a fluid particle?
Let the cross-sectional area in a straight nozzle be \(A(x)/A_0=1-a x/L\). In an ideal steady quasi-one-dimensional incompressible flow, continuity gives
The material acceleration is \(u\,du/dx\) although every stationary probe measures a constant velocity.

Read values from the plot
| Distance / nozzle length | Outlet / inlet area = 0.80 | Outlet / inlet area = 0.60 | Outlet / inlet area = 0.40 |
|---|---|---|---|
| 0 | 0.2 | 0.4 | 0.6 |
| 0.25 | 0.23327 | 0.5487 | 0.977 |
| 0.5 | 0.27435 | 0.78125 | 1.7493 |
| 0.75 | 0.32567 | 1.1662 | 3.6063 |
| 1 | 0.39062 | 1.8519 | 9.375 |
Interactive calculation · change the inputs of this example
Reduce the exit area and inspect where the acceleration grows fastest. Doubling inlet velocity quadruples the acceleration.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.
Chapter 2 · Hydrostatic pressure and forces on submerged surfaces
Derive pressure from a body-force balance and locate the resultant force on a vertical gate.
From first principles
Determine gate force by integrating hydrostatic pressure
Consider a liquid at rest, with constant density \(\rho\) under uniform gravity \(g\). Take depth \(h\) positive downwards from its free surface. A small horizontal fluid slice of area \(A\) and thickness \(dh\) has downward weight \(\rho gA\,dh\). Equilibrium requires the increase in bottom pressure force to equal that weight.
For a vertical plane gate with the same atmospheric pressure on its dry side, only this gauge pressure contributes to the net force. Its resultant follows by integrating \(\rho gh\) over the wetted area. Its line of action must also reproduce the pressure moment about the surface level.
Writing \(\int h^2dA=I_G+A\bar h^2\) gives
where \(I_G\) is the second area moment about the horizontal centroidal axis. The greater pressure at depth places the resultant below the centroid.
Derivation and applications
Find the horizontal and vertical forces on a curved gate
A curved gate generally feels both a horizontal and a vertical force from hydrostatic pressure. Consider a circular quarter-arc of radius \(R\) and width \(b\) perpendicular to the page. Place the arc centre at the free surface and choose \(x\) rightwards, \(z\) vertically downwards. The arc is \(x=R\cos\theta\), \(z=R\sin\theta\) for \(0\leq\theta\leq\pi/2\). Water occupies the circular sector on the centre side of the gate. Uniform atmospheric pressure on the other side cancels, and the liquid is stationary at constant density \(\rho\).
Integrating the horizontal component involves \(\sin\theta\cos\theta\). The resulting force equals the pressure force on the vertical projection of the arc, of height \(R\) and centroid depth \(R/2\).
The vertical component instead integrates \(\sin^2\theta\). It equals the weight of the imaginary water above the arc up to the free surface, which in this geometry is precisely the water sector itself.
Every elemental force lies along an arc radius, so the resultant line passes through the circle centre. Its magnitude follows from vector addition and its direction makes angle \(\arctan(\pi/2)\) below horizontal. The sign of the vertical reaction changes if the fluid bears on the opposite side.
Worked example
Size the reaction on a laboratory quadrant
With \(R=0.400\) m, \(b=0.600\) m and \(\rho=1000\) kg/m³, the common factor is
The horizontal and downward forces are 471 N and 740 N respectively. The resultant is
A bearing at the centre can react that force with no hydrostatic torque about its own axis.
Change the inputs and inspect this calculation below
Second application
Infer liquid density from the vertical component
A separate quarter gate has radius 0.300 m and width 0.500 m. After subtracting gate weight, its measured downward fluid force is 295 N. Inversion gives \(\rho=4F_z/(\pi gbR^2)=851\) kg/m³. The expected horizontal reaction magnitude is
This ratio tests the geometry without any independent density calibration.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Locate the force on an inclined circular viewing window
A circular window is installed below the water level in a laboratory tank. Knowing its total normal load is enough for one force balance. Sizing its hinge reaction also requires the moment of that load. The pressure increases with vertical depth, while the force elements must be integrated across an inclined surface. Distinguish distance down the window from depth below the surface before constructing the moment.
Let the window have radius \(a\), centre depth \(h_c\) and inclination \(\theta\) above the horizontal. Define \(s\) along its steepest downslope direction, measured from the disc centre. A point at \(s\) has vertical depth \(h_c+s\sin\theta\). With an atmospheric gas on the dry side, the differential normal force is \(\rho g(h_c+s\sin\theta)\,dA\). Since the first area moment \(\int s\,dA\) vanishes by symmetry, the resultant is simply \(\rho gh_c A\). Thus two windows of equal area at the same centre depth carry the same normal force even if their inclinations differ, provided both remain completely submerged.
To get the location of the force, take moments around the horizontal diameter through the window centre. The constant contribution to pressure gives zero moment about this axis, while the part proportional to \(s\) contributes \(\rho g\sin\theta\int s^2dA\). A circular disc has \(A=\pi a^2\) and diametral second moment \(I=\pi a^4/4\), which gives
For \(a=0.18\) m, \(h_c=0.42\) m, \(\theta=60^\circ\) and \(\rho=998\) kg/m³, the force is 418.55 N and acts 16.70 mm down the window from its centre. Its vertical depth is only \(16.70\sin60^\circ=14.46\) mm below the centre depth. A load strip of thickness \(ds\) has width \(2\sqrt{a^2-s^2}\). The notebook integrates the strip forces and their first moments independently to check the circular formula.

For a hinge along the upper tangent to the disc, the resultant lever arm is \(a+s_{\rm cp}\) measured down the window. Multiplying the default force by \(0.180+0.01670\) m gives approximately 82.3 N m. Treating the force as though it acted at the centre would predict only 75.3 N m. The difference of 7.0 N m equals the moment of the pressure gradient about the centre diameter. The hinge axis must lie in the plane of the window for this simple lever arm to apply. Changing to a vertical hinge introduces a different area moment and, for this symmetric disc, a different distribution of opening torque.
What changes when the window is lowered until its centre depth doubles at the same tilt?
Work through the solution
The normal force doubles and the downslope offset halves, to about 8.35 mm. Their product, the moment about the horizontal diameter through the disc centre, stays fixed because it depends only on the pressure gradient and the geometry. Rotate a fully submerged window to horizontal in the notebook and the offset goes to zero. If a window crosses the free surface, the wetted area and its centroid change; continuing to integrate the full disc would introduce fictitious negative gauge loads on dry strips.
Interactive calculation · Window force
Vary the notebook inputs and compare both plotted observables. The same equations generate the browser curves and the notebook reference; fixed material, geometry and model assumptions are stated in the readout.
Interactive calculation · Window offset
Vary the notebook inputs and compare both plotted observables. The same equations generate the browser curves and the notebook reference; fixed material, geometry and model assumptions are stated in the readout.
Balance a stationary fluid element
A diver experiences pressure from all directions, while a sluice gate feels a net force mainly from one side. Pressure is a scalar state variable. The force on a surface element is directed opposite its outward normal and has magnitude \(p\,dA\). The net force on a real gate also depends on what presses on its back face. For a fluid at rest there is no viscous shear. Take a thin horizontal slab of area \(A\) and thickness \(dz\), with \(z\) upward. Its vertical force balance is \(p(z)A-p(z+dz)A-\rho gA\,dz=0\), or \(dp/dz=-\rho g\).
For constant density this integrates to \(p=p_s+\rho gh\) at depth \(h\) below a free surface of pressure \(p_s\). A vented water surface has atmospheric absolute pressure. Gauge pressure subtracts that same atmospheric pressure at every point. It is convenient for net forces when the other face is exposed to the same atmosphere. A sealed gas space with appreciable excess pressure adds a uniform load component to the hydrostatic triangle.
Background · Which way does a liquid surface tilt in an accelerating tank?
Consider a tank translating horizontally at uniform acceleration \(a\) to the right. After sloshing has subsided, the liquid is stationary relative to the tank. In that frame each parcel has an effective body acceleration \(-a\mathbf e_x-g\mathbf e_z\). Along a free surface at uniform atmospheric pressure the pressure gradient has no tangential component.
The free surface falls to the right. A tank 0.80 m long accelerating at 1.2 m/s² exhibits a height difference of about 98 mm between the ends, provided neither end spills or dries out. This argument uses the uniform translating frame; a tank that is still sloshing has additional relative accelerations.
Use two separate integrals
For a flat vertical gate, add horizontal pressure forces to get
where \(p_g\) is the pressure difference across it. To find the force’s depth \(h_R\), match its moment:
With a vented free surface on one side and air on the other, this gives
Decomposing the second moment into centroidal and parallel-axis pieces gives
Here \(I_G\) is the area’s second moment about its horizontal centroidal axis. Its SI unit is m⁴. The second term is positive: lower parts of a vertical gate carry more force per unit area, moving the resultant below the area centroid.
Calculate hinge moment before actuator force
A 1.20 m wide rectangular gate extends from the water surface to depth 1.80 m. Its horizontal hinge is at the surface. At the bottom the gauge pressure is \(1000(9.81)(1.80)=17.7\) kPa. The triangular pressure profile integrates to \(F=\rho g bH^2/2=19.1\) kN. The resultant lies at \(2H/3=1.20\) m beneath the hinge, producing a moment of 22.9 kN·m. A horizontal actuator at the bottom must pull with magnitude \(22.9/1.80=12.7\) kN to balance this water moment. This excludes gate weight and friction at the hinge.
If the whole gate is submerged another metre with both ends still separated from the same air pressure on the back, its pressure diagram gains a uniform rectangle. That additional resultant acts at the gate centroid. It increases hinge moment, while the centre of pressure of the total load moves closer to the centroid measured relative to the gate. Simply adding one metre to the original lever arm would confuse a depth measured from the surface with a moment arm measured from the hinge.
Include stratification and buoyancy
In layered immiscible liquids, integrate \(\rho g\) through each layer. Pressure remains continuous across a flat interface when capillary effects are negligible, while its depth gradient changes. For a closed submerged object the resultant pressure force is upward with magnitude equal to the displaced fluid’s weight. To see this, replace the body by the fluid that would occupy its volume. In static equilibrium surface pressure must balance that fluid’s weight; the same surface pressure acts on the original object. Buoyancy concerns the net force on a closed surface. It cannot replace a hinge-moment calculation on an open gate.
Read a two-fluid differential manometer
Two water taps at the same elevation connect to opposite legs of a manometer containing a heavier immiscible liquid of density 2500 kg/m³. If the heavy-fluid interfaces differ in height by 40 mm, following a hydrostatic path gives a pressure difference \((2500-1000)g(0.040)=589\,\mathrm{Pa}\). The tap above the lower heavy-fluid interface has the larger pressure. The water columns matter even though both taps sit at the same elevation.
Derive a restoring moment for a floating body
Equality of weight and buoyancy establishes vertical equilibrium of a floating body, but does not determine whether a small roll is restored. Consider a long prismatic pontoon with vertical sides floating at rest in a liquid of uniform density. Let the displaced volume be \(\nabla\), its centroid the centre of buoyancy \(B\), and the centre of gravity \(G\) on the upright symmetry axis. For a small heel angle \(\theta\), a strip of waterplane area \(dA\) at transverse coordinate \(y\) gains a submerged slice of volume approximately \(y\theta\,dA\) on one side and loses one on the opposite side.
The first moment of these changed wedges shifts the centre of buoyancy sideways by \(\Delta y_B=\theta\int y^2dA/\nabla=\theta I_{\rm wp}/\nabla\). Thus the line of buoyancy in the tilted configuration intersects the original symmetry axis at a point \(M\), the transverse metacentre, located \(BM=I_{\rm wp}/\nabla\) above \(B\) to first order. The initial righting lever is \(GM\sin\theta\simeq GM\,\theta\), and the corresponding restoring moment magnitude is \(WGM\theta\) when \(GM>0\).
The waterplane second moment here is taken about the longitudinal heel axis; it is not the structural bending second moment of the vessel wall. A wide waterplane can increase stability without changing the weight because its outer strips contribute strongly to \(I_{\rm wp}\). A centre of gravity above the centre of buoyancy can still be stable if it remains below the metacentre.
Measure a pontoon’s centre of gravity by shifting a weight
A rectangular pontoon 4.0 m long and 2.0 m wide floats with 0.40 m draft in freshwater. Its displaced volume is \(4(2)(0.4)=3.20\,\mathrm{m^3}\), so the total supported mass is 3200 kg. The centre of buoyancy lies 0.20 m above the keel. Its waterplane moment is \(4(2^3)/12=2.667\,\mathrm{m^4}\), giving \(BM=2.667/3.20=0.833\,\mathrm m\) and \(KM=1.033\,\mathrm m\) above the keel.
Shift a pre-existing 100 kg test weight transversely by 0.40 m without changing its height. A settled heel of 2.0° balances the imposed heeling moment against buoyancy. For small heel the more accurate inclination-test expression is
The inferred unshifted vertical centre of gravity is
Raising a 400 kg installed component by 0.80 m would raise the combined centre by \(400(0.80)/3200=0.100\) m and reduce initial \(GM\) to 0.258 m. A slack liquid surface inside the pontoon or partial emergence of its deck edge changes the small-heel model; either can invalidate an extrapolation of the measured initial restoring moment to large roll angles.
For the original centre of gravity the initial rotational stiffness is
A loading estimate from a small known heeling moment can therefore serve as a separate check on the shifted-weight experiment. This stiffness is hydrostatic; rolling inertia and hydrodynamic damping are still required to predict a free-roll period or decay.
Place the hinge on a fully submerged vertical gate
A rectangular vertical gate is 2 m tall and of constant width. Integrate hydrostatic gauge pressure over its area. The centre of pressure is \(h_c+I_c/(A h_c)\), so the offset below the centroid shrinks as the gate is submerged more deeply.

Read values from the plot
| Depth of top edge (m) | Centre of pressure | Area centroid |
|---|---|---|
| 0 | 1.3333 | 1 |
| 0.76 | 1.9494 | 1.76 |
| 1.5 | 2.6333 | 2.5 |
| 2.24 | 3.3429 | 3.24 |
| 3 | 4.0833 | 4 |
Interactive calculation · change the inputs of this example
Change gate height and compare the centroid with the centre of pressure. Width changes resultant force without changing its depth.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.
Study the full derivation
Gravity, capillarity and instability at a moving interface · Momentum, motion and transport in fluids
A flat interface can carry waves restored by gravity and surface tension. If its two liquids or gases move at different speeds, a band of those waves can grow. Derive the ideal threshold, identify the most vulnerable wavelength at onset and distinguish growth of an instability from advection of an otherwise stable disturbance.
Problem sheet 1 · Mass balances and hydrostatic loading
Determine the correct area, depth and system boundary before evaluating the force or volume flow.
1. Audit a branching pipeline
A 100 mm pipe supplies water at mean speed 1.00 m/s. One 60 mm branch carries 2.50 L/s; the remaining water leaves through a 50 mm branch. (a) Find the inlet flow and both branch speeds. (b) If discharge from the smaller branch is actually 4.00 L/s, infer an accumulation or leak rate. (c) What observation distinguishes temporary storage from a persistent leak?
Close the volume budget
The inlet carries
The nominal branch speeds are
At the measured discharge the unaccounted rate is
A rising storage level or an expanding system volume could temporarily account for it. At constant inventory a persistent imbalance points to another flow path or meter offset.
2. Locate pressure with two liquids
A vented tank has 0.40 m of oil of density 800 kg/m³ over 0.80 m of water. (a) Find gauge pressure at the interface and at the base. (b) Find the net horizontal force on a 0.50 m wide vertical wall segment extending only over the water depth. (c) Why is a single triangular pressure diagram across the water segment insufficient?
Add the uniform and triangular loads
Interface pressure is \(800(9.81)(0.40)=3.14\) kPa. At the base add \(1000(9.81)(0.80)=7.85\) kPa to obtain 10.99 kPa. Assuming atmospheric pressure on the back, the average pressure on the water segment is
On 0.40 m² this gives 2.83 kN. Oil adds the uniform 3.14 kPa across the water segment. Using only the water triangle would omit 1.26 kN.
3. Move a gate hinge
A vertical gate is 1.0 m wide, extending from 0.50 to 1.50 m below a vented water surface. There is air behind it. (a) Find resultant force and its depth. (b) Find the water moment about a hinge at its lower edge. (c) Compare with a force applied at the centroid.
Match the force and its moment
The centroid depth is 1.0 m and the area is 1.0 m², giving 9.81 kN. The centroidal second moment is \(1(1)^3/12=0.0833\) m⁴. The resultant acts at \(1.0833\) m depth, with lower-hinge arm \(1.50-1.0833=0.4167\) m, giving 4.09 kN·m. Using the centroid would give 4.91 kN·m, too large because the greater pressure near the lower edge shifts the resultant towards that hinge.
Explore the governing equations after solving the sheet: Velocity fields, flow rates and conservation of mass; Hydrostatic pressure and forces on submerged surfaces. Compare the assumptions and units before transferring your chosen parameters; the controls may cover a different numerical range from the written exercise.
Notebook practice · Locate the force on an inclined circular viewing window
Chapter 3 · Control-volume momentum and forces on fittings
Use the velocity vector, gauge pressure and a consistent force boundary to find the support load on a pipe bend.
From first principles
Relate a support reaction to momentum carried by a stream
Newton's second law applies to a fixed set of fluid particles: external force equals the time derivative of their momentum. In a pipe bend it is easier to observe a stationary control volume that particles continually enter and leave. The rate of change for the material particles consists of storage in that volume plus the net rate at which momentum crosses its boundary.
The dot product determines whether mass crosses inwards or outwards, while the other velocity factor retains the direction of the momentum carried. For steady uniform inlet and outlet sections, the flux integral reduces to
Pressure pushes inward normal to each open section, so its contribution must be included before solving for the wall force. The force of the fluid on the bend is opposite to the wall's force on the fluid. Equal inlet and outlet speed can still give a substantial support load when their directions differ.
Derivation and applications
Derive the irreversible head loss across a sudden expansion
A sudden enlargement slows a liquid and partly restores static pressure. Consider steady incompressible flow from area \(A_1\) into area \(A_2>A_1\) in a horizontal pipe. Choose the downstream section after mixing has produced an approximately uniform velocity again. Approximate both station profiles as uniform, neglect wall shear over the short control volume and take the mean pressure on the annular shoulder to be the upstream pressure \(p_1\). Mass conservation makes the two mean speeds \(V_1,V_2\) proportional to inverse area.
The inlet and shoulder together contribute \(p_1A_2\) to the axial pressure force. Rearranging the momentum balance gives a positive downstream pressure rise, despite the separated mixing region.
Insert that pressure rise into the mechanical energy balance. The difference between kinetic energy released and pressure recovered is the specific energy dissipated in mixing, expressed below as a head of flowing liquid.
This result tends to zero quadratically as the area change vanishes. A gradual diffuser would require a different shoulder-pressure and separation model. Pressure recovery can thus coexist with positive mechanical-energy loss and its measurement alone does not provide the loss.
Worked example
Audit an abrupt pipe enlargement
Water moving at 3.00 m/s enters a pipe section with three times the area. Its final speed is 1.00 m/s. Taking \(\rho=1000\) kg/m³, the pressure rises by \(1000(1.00)(2.00)=2.00\) kPa. The kinetic pressure falls by 4.00 kPa; the missing 2.00 kPa is a head loss of 0.204 m. For 6.00 L/s, the rate of mechanical energy dissipation is \(Q\rho g h_L=12.0\) W.
Change the inputs and inspect this calculation below
Second application
Recover the enlargement ratio from a head test
Another rig measures \(V_1=2.50\) m/s and \(h_L=0.0800\) m. Taking the positive speed drop yields
The inferred area ratio is \(A_2/A_1=V_1/V_2=2.00\) to the stated precision. The expected water pressure rise is about 1.56 kPa, a separately measurable check on the shoulder-pressure assumption.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Momentum crosses the boundary with the mass
A pipe bend can exert a substantial force on its supports even when its inlet and outlet speeds agree. Momentum has direction. Turning a stream requires force and gives the fitting an equal and opposite load. Enclose the fluid inside the fitting in a fixed control volume. The external forces include wall traction, pressure on the control surfaces and body forces such as gravity.
A surface element transports mass per second \(\rho(\mathbf u\cdot\mathbf n)dA\). Multiply by the local velocity to obtain momentum per second. Newton’s second law applied to the control volume reads
For a steady fitting with nearly uniform inlet and outlet velocities this reduces to a sum of outgoing \(\dot m\mathbf u\) minus incoming \(\dot m\mathbf u\). Use one fixed set of axes even as pipe directions change. Pressure always pushes into the control volume, whereas the flux carries the direction of the local velocity, including its sign on the chosen axis.
Include the end pressures explicitly
Take a horizontal bend turning water from the positive \(x\) direction to the positive \(y\) direction. The inlet and outlet areas are each 0.010 m² and \(Q=0.040\,\mathrm{m^3/s}\). Their speeds are both 4.0 m/s and \(\dot m=40\) kg/s. The net outward momentum flux vector is \((-160,+160)\) N. Let the gauge pressures be 90 kPa at inlet and 80 kPa at outlet. Pressure pushes +900 N in \(x\) through the inlet and −800 N in \(y\) through the outlet.
Let \(\mathbf W\) be the fitting’s wall force on the enclosed fluid, with external atmospheric effects accounted for consistently using gauge pressures. Then \(\mathbf W+(900,-800)=(-160,160)\) N, giving \(\mathbf W=(-1060,960)\) N. The fluid’s net gauge load on the fitting is the opposite, \((1060,-960)\) N, of magnitude 1.43 kN. Supports plus connected pipework must provide the opposite force for a stationary fitting, in addition to carrying the weight of hardware and fluid. The strongest contribution here stems from the pressure terms, despite the conspicuous turn in velocity.
Recover momentum from a nonuniform profile
A flow meter usually measures \(Q\), not \(\int u^2dA\). At a plane normal to a unidirectional profile define \(\beta=\int u^2dA/(A\bar u^2)\). Then the axial momentum rate is \(\beta\rho Q\bar u\). Uniform flow gives \(\beta=1\). For a developed laminar circular pipe \(u=2\bar u[1-(r/R)^2]\); inserting \(dA=2\pi r\,dr\) in the integral gives \(\beta=4/3\). The largest velocities carry a disproportionate share of momentum. If one bend cross-section admits strong swirl or backflow, resolve vector fluxes instead of applying a single profile coefficient.
Recognise an open-stream boundary
A free jet at atmospheric pressure strikes a fixed flat plate normal to its axis and turns into a thin sheet that leaves sideways. Neglecting rebound and friction far from the impact, the outgoing axial momentum flux is zero. For water flowing at 10 m/s through a 20 mm diameter nozzle, \(\dot m=3.14\) kg/s, so the axial force on the plate is 31.4 N. Both the incoming and outgoing free-stream control surfaces have zero gauge pressure. The plate force then follows entirely from the change of momentum. A nozzle bolted to a pressurised pipe would require different pressure forces even if it produced exactly the same free jet.
A jet catches a moving vane
Consider a single flat vane moving steadily in the jet direction at speed \(u\). In the vane frame the arriving volume rate is \(A(V-u)\) and the incoming streamwise relative velocity is \(V-u\). If the jet spreads tangentially across the face, the resulting normal force is \(\rho A(V-u)^2\). For water, \(A=2.0\,\mathrm{cm^2}\), \(V=10\) m/s and \(u=4\) m/s, this gives 7.2 N. Its mechanical power on the moving vane is \(Fu=28.8\,\mathrm W\). Using the stationary volume rate would count fluid parcels that the moving vane never catches.
Derive the two depths of a hydraulic jump
A hydraulic jump converts shallow fast open-channel flow into deeper slow flow over a short distance. Turbulent mixing dissipates mechanical energy, so applying an inviscid energy balance between the two uniform sections would miss its defining loss. Instead choose a control volume bounded by sections before and after the roller, the horizontal bed and the free surface. Approximate the velocity as uniform and the pressure distribution as hydrostatic at the two end sections. Atmospheric pressure cancels, and over the short reach assume the integral of bed friction is small compared with the pressure and momentum forces.
In a rectangular channel per unit width let the volume rate be \(q\), depths \(y_1,y_2\) and speeds \(v_i=q/y_i\). The horizontal pressure resultant per width is \(\rho g y_i^2/2\). Equating pressure force difference to momentum-flux change gives
One solution is the unchanged depth. Factoring out \(y_2-y_1\) for the nontrivial solution gives
With upstream Froude number \(Fr_1=v_1/\sqrt{g y_1}\), the downstream-to-upstream depth ratio becomes \([\sqrt{1+8Fr_1^2}-1]/2\). The deeper downstream branch occurs when \(Fr_1>1\). As \(Fr_1\to1\), the ratio tends to unity and the finite jump disappears.
Calculate the energy dissipated in a channel transition
A horizontal test channel carries water at \(y_1=0.20\,\mathrm m\) and \(v_1=4.0\,\mathrm{m/s}\). Its unit-width discharge is \(q=0.80\,\mathrm{m^2/s}\) and Froude number is
The depth ratio is about 3.57, giving \(y_2=0.714\,\mathrm m\) and \(v_2=0.80/0.714=1.12\,\mathrm{m/s}\). The downstream Froude number is about 0.42. These are conjugate depths for the specified momentum balance; the tailwater has to support the downstream depth for a stationary jump to sit at the chosen location.
Using specific mechanical head \(E=y+v^2/(2g)\), the inlet and outlet give 1.015 and 0.778 m respectively. The loss is approximately 0.237 m of water, or \(1000(9.81)(0.80)(0.237)=1.86\,\mathrm{kW}\) dissipated per metre of channel width. Substitution of the momentum relation into the energy difference gives
which is positive for the physical jump and approaches zero rapidly for a weak jump. This is a useful cross-check on a measured depth pair. If measurements are taken within the roller, pressure may be nonhydrostatic and velocity markedly nonuniform; using those sections in the simple end-state formula can produce an apparent energy or momentum imbalance.
Another discrimination comes from comparing the two depths with an upstream energy curve. At \(q=0.80\) m²/s, a downstream depth giving exactly the upstream energy would have to satisfy \(y+0.03262/y^2=1.015\). The deeper root is about 0.981 m, appreciably deeper than the momentum-predicted 0.714 m. Pairing those equal-energy depths would require an additional horizontal force or a different channel geometry to satisfy momentum. A smooth reversible change over a channel hump can conserve specific head while changing velocity and depth; a jump on a flat bed instead conserves the appropriate momentum function while dissipating head. Laboratory measurements of both levels are sufficient to distinguish the two idealisations.
Resolve the momentum force on a turning guide
A steady free water jet of mass flow 6 kg/s enters a smooth stationary guide at 20 m/s and leaves with the same speed at the indicated angle. Inlet and exit are at ambient pressure. Neglect weight for this short control volume. Reaction on the guide is the negative of the fluid momentum change.

Read values from the plot
| Outlet deflection (degrees) | Streamwise | Transverse | Resultant magnitude |
|---|---|---|---|
| 0 | 0 | 0 | 0 |
| 40 | 28.075 | −77.135 | 82.085 |
| 80 | 99.162 | −118.18 | 154.27 |
| 120 | 180 | −103.92 | 207.85 |
| 160 | 232.76 | −41.042 | 236.35 |
Interactive calculation · change the inputs of this example
Compare a right-angle turn with a complete reversal. The transverse force requires vector momentum, not just speed magnitude.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.
Chapter 4 · Bernoulli head, losses and pump duty
Build a mechanical-energy balance between two stations and distinguish a recoverable pressure change from irreversible loss.
From first principles
Derive mechanical head along a streamline
Take steady inviscid flow of constant-density liquid under gravity. Along a streamline use distance \(s\), speed \(V\) and elevation \(z\) positive upwards. Tangential acceleration of a parcel is \(V\,dV/ds\) because the parcel moves from one position to the next. Pressure gradient and gravity provide the tangential force per unit volume. Dividing their balance by density gives
Each term is a derivative along the path. Integrating between two positions shows that their sum, written as energy per unit mass, is conserved under the stated assumptions.
Dividing by \(g\) converts all terms into lengths called heads. In a pipe system one measures added pump head \(H_p\), removed turbine head \(H_t\) and irreversible loss \(h_L\) to form a section-to-section engineering balance. For uniform profiles this reads
This distinguishes a reversible pressure drop associated with acceleration from a loss of total mechanical head.
Background · Head loss
This is an irreversible loss expressed as a length. A static pressure change can also include reversible changes of speed or elevation.
Derivation and applications
Derive an ideal Venturi flow reading from two pressure taps
A narrowing can measure flow by reversibly trading pressure for speed. Take a horizontal Venturi meter carrying steady, incompressible liquid from a developed upstream section of area \(A_1\) into a throat of area \(A_2\). For an ideal first model assume uniform velocity at the two taps, negligible viscous loss between them, and no pump or turbine between stations. Pressure taps register static pressure. Define \(\beta=d_2/d_1\) for geometrically circular sections and use continuity to eliminate upstream speed.
The squared velocity is the source of the fourth power of diameter ratio. Substituting the continuity expression and multiplying throat speed by throat area gives the ideal meter law.
In an installed meter a calibrated discharge coefficient \(C_d\) relates actual flow to this model. At fixed geometry, density and coefficient, logarithmic differentiation produces a useful uncertainty relation for pressure-transducer readings.
The pressure difference between upstream tap and throat is larger than the permanent loss measured after the diffuser. Estimating pump power from the meter differential would therefore include recoverable pressure. At very small flow, a fixed pressure offset has a particularly large relative effect.
Worked example
Translate a pressure reading into discharge
A water meter has \(d_1=80.0\) mm, \(d_2=40.0\) mm, \(\rho=1000\) kg/m³ and \(C_d=0.980\). A 3.00 kPa differential corresponds to ideal throat speed \(\sqrt{6/0.9375}=2.53\) m/s. Actual discharge is
A 30 Pa differential error represents one percent of the measured drop, giving approximately 0.5 percent flow error.
Change the inputs and inspect this calculation below
Second application
Calibrate a second meter against a collection tank
A meter with \(\beta=0.600\) and \(A_2=600\) mm² gives 2.00 kPa differential for a liquid of density 800 kg/m³. Its ideal flow is
Collecting 14.0 L in 10.0 s indicates 1.40 L/s, hence \(C_d=0.974\) after using unrounded intermediate values. Repeating at other flow rates tests whether one constant coefficient is appropriate.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Integrate the acceleration along a streamline
A nozzle can lower static pressure while increasing speed. A valve can also lower pressure, yet recover little useful speed downstream. To separate the mechanisms, start from a steady, inviscid streamline in constant-density flow. Project Newton’s equation along its tangent \(s\), with gravity acting downward. The acceleration in that direction is \(u\,du/ds\), giving \(\rho u\,du=-dp-\rho g\,dz\). Integration between points on that streamline gives \(p/\rho+u^2/2+gz=\) constant.
The three terms have units J/kg. Dividing by \(g\) measures the same energies as equivalent lengths of fluid column, called pressure head, velocity head and elevation head. A rise in speed at constant elevation can be paid for by a drop in static pressure even in lossless flow. Bringing such a stream to rest along a short, nearly lossless streamline would convert velocity head back into stagnation pressure. An irreversible loss reduces that recoverable total.
Add distributed losses and machinery
For a steady incompressible stream between stations with approximately uniform profiles, a pump supplies head \(H_p\) and a turbine extracts head \(H_t\). Viscous losses \(h_L\) appear as mechanical energy converted into internal energy. With endpoints numbered in the flow direction the energy balance is
For a noticeably nonuniform profile, multiply each velocity-head term by the kinetic-energy correction \(\alpha=\int_Au^3dA/(A\bar u^3)\). It differs from the momentum correction because energy flux weights the cube of velocity. Long straight pipes are commonly modelled with the Darcy loss \(f_D(L/D)\bar u^2/(2g)\) and fittings with \(K\bar u^2/(2g)\). State which pipe diameter supplies the reference velocity for each coefficient.
Lift water between open tanks
Two large vented reservoirs differ in elevation by 8.0 m. Water flows at \(Q=0.010\,\mathrm{m^3/s}\) through 40 m of 80 mm diameter pipe. Use a supplied Darcy friction factor 0.025 and total fitting coefficient 3.0, including entrance and exit losses. Both free surfaces have atmospheric pressure and negligible velocity. The pipe area is \(5.03\times10^{-3}\) m², giving mean speed 1.99 m/s and velocity head 0.202 m. Friction and fittings dissipate \([0.025(40/0.080)+3.0]0.202=3.13\) m. The pump therefore supplies 11.13 m head.
The hydraulic power is \(\rho gQH_p=1.09\) kW for \(\rho=1000\) kg/m³. A pump with efficiency 0.70 at this duty requires 1.56 kW of shaft power. Elevation work alone would predict 0.785 kW hydraulic, and electrical input would also require the motor and drive efficiencies. These differences reflect which boundary is used for the energy balance.
Find the intersection with the pump characteristic
If coefficients are treated as fixed, the system head here has the form \(H_{\rm sys}=8+BQ^2\). Doubling the flow quadruples the losses, not the elevation rise. A real pump produces a head that depends on flow rate and rotational speed. Its steady operating point is where available head equals required head. Partially closing a valve increases \(B\); it does not directly prescribe a particular flow. Readjusting pump speed changes its characteristic instead. In a real design recheck friction factor and efficiency at the new rate. At low Reynolds number, where laminar friction factor varies inversely with speed, the distributed loss becomes linear rather than quadratic in flow.
Check the absolute pressure on a pump inlet
A pump inlet sits 3.0 m above an open water reservoir. At a particular duty the suction-line speed is 2.0 m/s and the loss between reservoir and inlet is 0.60 m. Atmospheric pressure is 101 kPa. Applying the mechanical energy balance upstream of the impeller gives absolute inlet pressure \(101000-1000(9.81)(3.0+0.60)-1000(2.0)^2/2=63.7\,\mathrm{kPa}\). If the supplied vapour pressure is 2.3 kPa, this tapping remains above it. Pressure may fall further inside the impeller. Evaluating cavitation margin requires the pump’s suction requirement at the actual duty and an absolute pressure reference; a negative gauge pressure at the tapping alone does not establish cavitation.
Locate the critical depth from a constrained energy minimum
In open-channel flow the atmosphere fixes the free-surface pressure, while the depth and speed can both adjust. Consider a rectangular channel of constant width with slowly changing bed elevation \(z_b\). Define the discharge per unit width \(q=vy\) and use the bed as the local elevation datum. With nearly hydrostatic pressure and approximately uniform section velocity, the mechanical head relative to the bed is \(E(y)=y+q^2/(2gy^2)\). This specific energy is finite at a given depth but diverges both for a very shallow stream at fixed discharge and for a very deep stream.
At fixed \(q\), differentiate with respect to \(y\): \(dE/dy=1-q^2/(gy^3)\). The stationary depth is \(y_c=(q^2/g)^{1/3}\), its Froude number is one, and the second derivative \(3q^2/(gy^4)\) is positive. The minimum value is
For any specific energy above this minimum two positive depths are possible. One is deep and slow and the other shallow and fast. One must know the upstream flow regime and the physical control to choose a branch.
Across a smooth low hump with negligible loss the total head \(z_b+E\) remains constant. Raising the bed reduces the specific energy available at the crest. On the deep branch depth decreases towards critical, whereas on the shallow branch depth increases towards it. These opposite trends follow from the sign of \(dE/dy\). Neither branch can pass below \(E_c\) at the prescribed discharge.
Predict when a raised bed changes the upstream water level
Water enters a wide rectangular flume at \(y=0.80\,\mathrm m\) and \(v=1.0\,\mathrm{m/s}\), giving \(q=0.80\,\mathrm{m^2/s}\) and upstream specific energy \(E_1=0.8510\,\mathrm m\). The critical depth is \((0.64/9.81)^{1/3}=0.4025\,\mathrm m\), so \(E_c=0.604\,\mathrm m\). The largest ideal bed rise that leaves the upstream state unchanged is
For a smaller 0.15 m bed rise the crest must have \(E=0.7010\,\mathrm m\). Solving \(y+0.03262/y^2=0.7010\) on the deep branch gives approximately 0.614 m, which can be checked by substitution. Speed increases to about 1.30 m/s while the stream remains subcritical.
Raise the crest instead by 0.30 m. The unchanged upstream level would provide only 0.551 m specific energy, less than the minimum. If discharge stays fixed, the upstream surface must rise until at least \(E_1=0.30+0.604=0.904\,\mathrm m\) is available. The subcritical solution upstream is then approximately 0.860 m depth, a rise of about 60 mm. The physical limitation is the minimum section energy for the prescribed flow, not a loss of mass. Adding appreciable crest losses would require an even larger upstream head to sustain the same discharge.
A depth gauge right at a critical crest is relatively insensitive as an energy measurement: the first derivative \(dE/dy\) vanishes there. Conversely, inferring depth from a noisy measured head becomes sensitive near the minimum because the inverse slope becomes large. Measurements upstream and downstream help identify which of the two nearby depth branches is physically present.
Problem sheet 2 · Forces, flow work and losses
Use momentum to predict a support load and mechanical energy to predict pressures and pump power.
1. Calculate the load on a contraction
A horizontal water nozzle carries 0.020 m³/s. Its inlet area is 0.010 m², outlet area 0.0020 m², inlet gauge pressure 60 kPa and outlet atmospheric. Assume uniform profiles. (a) Find the momentum change per second. (b) Find the gauge force of the fluid on the nozzle. (c) Infer the head loss from the specified data.
Separate force and energy checks
The inlet and exit speeds are 2.0 and 10 m/s. Net downstream momentum flux is
Inlet pressure supplies 600 N, so the nozzle wall exerts −440 N on the fluid and the fluid exerts +440 N on the nozzle. The available pressure head is
The velocity head increases by \((100-4)/(2g)=4.89\) m, leaving a positive 1.22 m loss. A lossless calculation would yield a different inlet pressure for that flow.
2. Select pump duty for two reservoirs
A pump delivers 6.0 L/s to a vented reservoir 12 m above its source. The losses at this rate are 3.0 m. (a) Find hydraulic and shaft power at 75% efficiency. (b) If loss varies as \(Q^2\), repeat at 9.0 L/s. (c) Why is multiplying the first power by the flow ratio inadequate?
Add static lift and dissipative head
The original head is 15.0 m, so hydraulic power is \(1000(9.81)(0.006)(15)=883\) W and shaft power 1.18 kW. At 9 L/s the loss grows to \(3(1.5)^2=6.75\) m, giving 18.75 m total head. Hydraulic and shaft powers become 1.66 and 2.21 kW if efficiency remains unchanged. Flow enters directly in power and indirectly through the extra head needed to overcome losses.
3. Turn a free jet through 120 degrees
A 5.0 kg/s water jet travels horizontally at 8.0 m/s and leaves a fixed smooth guide at the same speed, turned 120° counterclockwise. (a) Find inlet and outlet velocity components. (b) Obtain the force of water on the guide. (c) Determine the guide’s mechanical power and reconcile it with its force.
Balance vector momentum
With the incoming jet along \(+x\), the outlet velocity is \((-4.0,6.93)\) m/s. The guide’s force on the water is \(5[(-4,6.93)-(8,0)]=(-60.0,34.6)\) N when gravity is negligible and both surfaces have atmospheric pressure. Water acts on the guide with \((60.0,-34.6)\) N. The stationary guide has zero velocity and its mechanical power is zero. It changes momentum direction without changing the jet’s speed or kinetic-energy rate.
Explore the governing equations after solving the sheet: Control-volume momentum and forces on fittings; Bernoulli head, losses and pump duty. Compare the assumptions and units before transferring your chosen parameters; the controls may cover a different numerical range from the written exercise.
Chapter 5 · Viscous stresses, duct resistance and wall-driven flow
Derive a developed velocity profile from momentum balance and distinguish a moving-wall contribution from a pressure-driven contribution.
From first principles
Derive the parabolic velocity profile between stationary plates
Consider steady fully developed flow between wide parallel plates at \(y=0\) and \(y=H\). Assume incompressible Newtonian fluid, constant viscosity \(\mu\), no slip, no variation across the channel width and no streamwise body force. Let \(G=-dp/dx>0\) drive flow in the positive \(x\) direction. Since the axial velocity depends only on \(y\), the convective acceleration is zero. A thin fluid layer balances pressure force against the change of shear stress across its thickness.
Integrate twice and apply zero velocity at both walls. The resulting velocity is largest halfway between the walls, where the shear stress vanishes. Integrating the profile gives discharge per unit width.
The cube of the gap arises because widening the channel increases both conducting area and the speed at a given pressure gradient. A moving wall adds a linear shear-driven profile through the boundary condition because the governing equation is linear.
Open full-size diagram
Derivation and applications
Quantify the effect of wall slip on laminar pipe resistance
A pressure-flow calibration of a small tube can reveal a change in the assumed wall condition. Consider steady, fully developed, axisymmetric flow of a Newtonian liquid of viscosity \(\mu\) in a round tube of radius \(R\). Take the pressure gradient magnitude \(G=-dp/dz>0\) and neglect body forces along the tube. Balance pressure force against viscous drag on a coaxial fluid cylinder of radius \(r\). Positive axial speed decreases approaching the wall.
Allow a Navier slip length \(b\geq0\) at the stationary wall: the wall speed extrapolates to zero a distance \(b\) beyond it in a local linear approximation. This gives
Integrating the shear rate from the wall into the flow adds a uniform velocity offset to the usual parabola.
Integrate the velocity over annuli to turn a local change of boundary condition into a measurable discharge. The contribution from the offset is proportional to the full area because the velocity addition is constant over the cross-section.
The shear stress needed to balance a fixed pressure gradient is unchanged. Effective slip lowers the required pressure gradient for a fixed flow. When \(b/R\) is small the fractional change is proportional to \(b/R\), making small tubes more sensitive at a given slip length.
Worked example
Calculate the extra discharge of a coated tube
Take \(R=100\) µm, \(b=5.00\) µm, \(\mu=1.00\) mPa s and \(G=10.0\) kPa/m. The no-slip flow is \(\pi(10^4)(10^{-4})^4/(8\times10^{-3})=0.393\) µL/s. Slip increases it by \(4b/R=0.200\), yielding 0.471 µL/s. The predicted wall speed \(GbR/(2\mu)=2.50\) mm/s could be examined by a near-wall tracer.
Change the inputs and inspect this calculation below
Second application
Infer a slip length from pressure reduction
A different tube of radius 40.0 µm requires only 80.0 percent of the reference no-slip pressure drop to sustain the same flow. Equal flow implies \(1+4b/R=1/0.800=1.25\), giving \(b=2.50\) µm. A radius calibration error can mimic this signal because the no-slip flow varies as \(R^4\). Independent bore measurements are therefore especially informative in this inverse experiment.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Transport momentum between neighbouring layers
Push two parallel plates past one another with liquid in the gap. Even at constant velocity the moving plate requires force. In a Newtonian fluid the tangential shear stress on a plane parallel to the motion is \(\tau_{xy}=\mu\,du/dy\). Dynamic viscosity \(\mu\) has units Pa·s. Divide it by density to obtain kinematic viscosity \(\nu\), an indicator of how rapidly momentum spreads through the fluid. Viscous resistance depends on a velocity gradient; uniform translation of the entire fluid would not create such stress.
Take two long horizontal plates separated by \(H\). Far from inlet and side walls assume constant density, constant viscosity and steady fully developed laminar motion \(u=u(y)\). The lower plate is fixed and the upper moves at speed \(U\). Represent the constant driving pressure gradient by \(G=-dp/dx\), positive for pressure falling downstream. A differential slab balances the downstream pressure force with the change in shear, giving \(0=G+d\tau_{xy}/dy=G+\mu u''\).
Impose the two wall velocities
The first integration gives
Integrating again and imposing no slip \(u(0)=0,\ u(H)=U\) determines the constants. The result is the sum of a straight wall-driven profile and a parabolic pressure-driven one:
Superposition here follows because the reduced equation and boundary conditions are linear in these inputs. It is not a universal property of the full nonlinear fluid equations. A negative \(G\) represents an adverse pressure rise and can produce a reverse-flow layer close to the stationary wall even when the moving wall drags fluid forward elsewhere.

Predict the pressure a moving surface can hold
An oil film has \(\mu=0.050\) Pa·s, \(H=1.0\) mm and \(U=0.20\) m/s. The wall-driven flux per unit width is \(UH/2=1.0\times10^{-4}\) m²/s. An adverse pressure gradient sufficient to reduce net flux to zero must satisfy \(G=-6\mu U/H^2=-60\,000\) Pa/m. Over 50 mm, pressure rises by 3.0 kPa. Zero net transport does not make the oil stationary.
Set \(s=y/H\) and insert the zero-flux gradient. The velocity is \(u/U=3s^2-2s\), which changes sign at \(s=2/3\) inside the film. The velocity gradient at the upper moving wall is \(4U/H=800\,\mathrm{s^{-1}}\), so the wall supplies shear of magnitude 40 Pa. Even though the pressure-driven and wall-driven volume rates cancel, the moving surface still performs work, dissipated through the internal shear field.
Connect a local solution to a network
In a horizontal circular tube with fixed wall, axisymmetry changes the area that carries shear. Balancing forces on a cylinder of radius \(r\) gives
Integrating the velocity gradient with no slip yields
Thus a straight developed pipe behaves as a hydraulic resistance \(8\mu L/(\pi R^4)\) in Pa·s/m³. Series resistances carry the same \(Q\) and their pressure drops add. Parallel branches share pressure drop and their flows add. The analogy requires consistent units and a laminar regime; short entrance sections and strongly accelerating junctions may add losses outside the fully developed solution.
Express pipe resistance as a friction factor
For a circular pipe of diameter \(D=2R\), the developed laminar solution gives
Define the Darcy friction factor by \(\Delta p=f_D(L/D)\rho\bar u^2/2\). Equating these expressions produces \(f_D=64/\mathrm{Re}_D\). For 2 m of 10 mm pipe with mean speed 0.10 m/s, water viscosity 0.001 Pa s and density 1000 kg/m³, the Reynolds number is 1000 and the pressure drop is 64 Pa. A friction factor listed in the Fanning convention is one quarter of the Darcy value, so identify the convention before substituting a tabulated number into a loss calculation.
Derive the profile of a shear-thinning liquid in a pipe
A Newtonian viscosity inferred in one duct may give poor predictions for a suspension or polymer solution at another rate. In a simple power-law model the shear stress magnitude is \(\tau=K|\dot\gamma|^n\), with consistency \(K\) in Pa sⁿ and index \(n\). A liquid with \(n<1\) has apparent viscosity decreasing with shear rate. Assume this law is supported over the shear range being sampled, flow is steady, axisymmetric, laminar and fully developed, and the circular pipe has no wall slip. The axial force balance is independent of rheology: at radius \(r\), \(\tau=Gr/2\) for driving gradient \(G=-dp/dx>0\).
Since the positive downstream velocity decreases towards the wall, write \(-du/dr=(Gr/2K)^{1/n}\). Integrate from radius \(r\) to the stationary wall at \(R\), then integrate the result over the circular cross-section to obtain
Setting \(n=1,\ K=\mu\) gives the parabolic profile and \(Q=\pi GR^4/(8\mu)\). For \(n<1\) the velocity is flatter towards the centre and the relationship between pressure gradient and flow rate is nonlinear. The ideal power law can imply unrealistic apparent viscosity near zero shear at the axis; a fitted model with finite limiting viscosities is preferable when measurements resolve those regimes.
Infer a pressure demand from wall shear
A model resin follows \(n=0.50,\ K=0.80\,\mathrm{Pa\,s^{0.5}}\) in the operating range. A 2.0 m pipe of radius 5.0 mm experiences a pressure drop of 8.0 kPa, giving \(G=4000\,\mathrm{Pa/m}\) and wall shear \(\tau_w=GR/2=10.0\,\mathrm{Pa}\). The wall shear rate is
Writing the mean speed in terms of this wall value gives
The corresponding flow is \(\pi(0.005)^2(0.15625)=1.227\times10^{-5}\,\mathrm{m^3/s}\), about 0.736 L/min.
To double flow in this same pipe, the power-law relation requires the gradient to rise by \(2^n=\sqrt2\). The new pressure drop is 11.3 kPa, and wall shear rate doubles to 312.5 s⁻¹. A linear resistance model extrapolated from the original measurement would predict 16 kPa. Conversely at fixed gradient a 10% radius increase multiplies rate by \(1.1^{3+1/n}=1.61\), a stronger dependence than the Newtonian fourth power. Verify the resulting shear rate still falls in the tested rheological range, and check entrance length and temperature. Temperature changes produced by viscous dissipation can otherwise mimic a shear-dependent viscosity.
Two well-spaced steady pressure tests can independently infer the unknown exponent. At fixed pipe geometry,
If pressure drop rises from 8.0 to 12.0 kPa while flow rises from 0.736 to 1.66 L/min, the log slope is \(\ln(1.66/0.736)/\ln(12/8)\simeq2.00\), giving \(n\simeq0.50\). Repeating the higher-pressure point after cooling checks whether heating caused hysteresis between runs. Using an inlet pressure transducer alone would also include a changing downstream pressure; both end pressures or a differential gauge are needed to identify the flow law from this experiment.
The pressure taps should bracket the same developed length at every setting because entrance losses may change differently with flow.
How does a local pressure gradient accelerate a fluid particle?
A duct solution generally begins by cancelling terms in the momentum balance. To decide which terms can be cancelled, follow a small volume of fluid. Its acceleration includes the change in the velocity at its present location and the change as it moves into a different part of the velocity field. Applying the chain rule along its trajectory gives
Consider the two faces normal to the first coordinate axis. Their net surface force per unit volume in direction \(i\) approaches \(\partial_x\sigma_{ix}\) as the face separation tends to zero. Summing the three face pairs and adding weight gives
For an incompressible Newtonian liquid of constant viscosity \(\mu\), insert \(\sigma_{ij}=-p\delta_{ij}+\mu(\partial_j u_i+\partial_i u_j)\). The cross derivative sums to \(\partial_i(\nabla\cdot\mathbf u)=0\). The remaining terms are the local equations
Take a horizontal slice through an ideal planar stagnation region, away from confining walls. The steady field \(u=ax,\ v=-ay\) satisfies continuity. Every velocity component is linear, so its Laplacian vanishes. Nevertheless the material acceleration is \((a^2x,a^2y)\). Integrating the two horizontal gradients gives
where \(p_0\) is the stagnation-point pressure at this elevation. For water at \(1000\,\mathrm{kg\,m^{-3}}\), \(a=4\,\mathrm{s^{-1}}\) and \(y=0.10\,\mathrm m,\ x=0\), pressure is 80 Pa below \(p_0\). Fluid entering along positive \(y\) moves towards the origin but accelerates in positive \(y\): it slows as pressure rises. At the stagnation point itself both velocity and acceleration vanish. Specifying \(p_0\) fixes the pressure datum. The velocity gradients determine the spatial change.
Interactive calculation · Change the inputs of this example
Change the parameters of this reference plot and compare its limiting cases. The fixed illustration remains beside the derivation; the adjustable calculation exposes the same dependence on geometry, material properties or loading.
Practise on sheet 3 · Which pressure difference establishes an accelerating uniform stream?. Further reading · MIT · 1.060 Engineering Mechanics II · Lectures 35–36, Differential Analysis of Fluid Flows: The Navier–Stokes Equation.
Study the full derivation
Why shear disperses a tracer faster than molecular diffusion · Momentum, motion and transport in fluids
A short dye pulse in a straight tube first stretches into a filament and much later resembles a broadened one-dimensional cloud. Derive the long-time Taylor–Aris coefficient, predict the width of a measured pulse and identify the mixing time needed before fitting the familiar one-dimensional approximation.
Chapter 6 · Dynamic similarity, boundary layers and model tests
Choose dimensionless groups for a fluid experiment and determine which full-scale predictions a scale model can support.
From first principles
Read similarity conditions from the nondimensional momentum balance
Two geometrically similar channels can behave differently when inertia, viscosity and gravity contribute in different proportions. Use incompressible Newtonian flow with density \(\rho\), kinematic viscosity \(\nu\) and constant gravitational acceleration \(\mathbf g\). Choose length \(L\), speed \(U\), elapsed time \(L/U\) and pressure scale \(\rho U^2\). The underlying balance is force per unit mass equals acceleration.
Insert \(\mathbf u=U\mathbf u^*\), \(\mathbf x=L\mathbf x^*\) and the other scales. Divide through by \(U^2/L\). The viscosity and gravity terms acquire coefficients that compare their acceleration scales with inertia.
Here \(\mathbf e_g\) points downwards. Matching the relevant coefficients and dimensionless initial and boundary conditions gives the same nondimensional problem. Choosing what to match therefore depends on which physical effects matter for the measured observable.
Background · Reynolds number
Choose speed and length scales appropriate to the geometry. Matching this ratio compares inertial and viscous terms under the stated nondimensionalisation.
Derivation and applications
Scale a rising interface with Reynolds and Froude numbers
A free-surface model can match gravitational wave motion and still misrepresent viscous drag. Consider two geometrically similar open-channel experiments with characteristic lengths \(L_m,L_p\), speeds \(U_m,U_p\), gravitational accelerations \(g_m,g_p\) and kinematic viscosities \(\nu_m,\nu_p\). Ignore surface tension only when the Bond number is sufficiently large in both channels. Compare the inertial acceleration \(U^2/L\) with gravity and viscous acceleration \(\nu U/L^2\). Their ratios define
Let \(\lambda=L_m/L_p\) be the model-to-prototype length ratio. Froude similarity fixes the velocity ratio because the shape and timing of long free-surface disturbances depend on the competition with gravity. Substituting this speed into Reynolds similarity fixes the required viscosity ratio as a second independent condition.
A travel time scales as length divided by velocity, and discharge scales as velocity times geometrically similar area. The matching free-surface kinematics therefore predict two distinct dimensional scale factors.
When the same liquid and gravity are used, exact equality of both dimensionless numbers is possible only at full scale. If boundary-layer details matter in a smaller channel, the calculated Reynolds mismatch quantifies what a Froude-scaled measurement leaves unresolved.
Worked example
Interpret a one-to-nine water channel
At equal gravity, \(\lambda=1/9\) gives a speed ratio of \(1/3\). A model flow of 0.400 m/s corresponds to 1.20 m/s at full scale. A 2.00 s wave passage scales to 6.00 s. With the same water, \(Re_m/Re_p=\lambda^{3/2}=1/27\), so a prototype Reynolds number of 270,000 becomes 10,000. Matching model surface-wave timing alone gives no guarantee of the same wall-shear coefficient.
Change the inputs and inspect this calculation below
Second application
Choose the viscosity for simultaneous matching
In a separate equal-gravity test, \(\lambda=1/4\) and the prototype liquid has \(\nu_p=8.00\) mm²/s. Simultaneous similarity requires \(\nu_m=(1/4)^{3/2}(8.00)=1.00\) mm²/s. A prototype discharge of 64.0 L/s maps to \(64.0(1/4)^{5/2}=2.00\) L/s. This pair of viscosity and discharge targets specifies two independently measurable conditions for commissioning the model.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Start from this chapter. At fixed distance, the Reynolds number doubles when the stream speed doubles. Predict the change in the ratio of layer thickness to distance before reading the output.
OneSimulation laboratory · Measure boundary-layer growth from a velocity profile
Compare competing mechanisms
A scale model can reproduce a shape exactly and still display a different flow pattern. A fast oil stream and a slow water stream may behave similarly if the relevant dimensionless groups match. To see which groups enter, choose a typical length \(L\), speed \(U\), time \(L/U\) and pressure change \(\rho U^2\) in the incompressible Newtonian momentum equation. Divide by the inertial scale \(\rho U^2/L\). The coefficient multiplying viscous diffusion becomes \(1/Re\), where \(Re=\rho UL/\mu\).
If gravity must be retained, its coefficient is \(1/Fr^2\), with \(Fr=U/\sqrt{gL}\). A free water surface makes this particularly important because gravity restores disturbances. For a fully submerged shape in a constant-density fluid, gravity can often be absorbed into hydrostatic pressure, leaving the Reynolds number dominant. Extra effects can introduce more groups, for example roughness divided by length or oscillation frequency times \(L/U\). Choose groups to match the phenomenon being measured.
Derive a near-wall length scale
Consider a smooth flat plate parallel to a uniform stream with a negligible pressure gradient. In a laminar boundary layer, momentum is advected downstream on a scale \(U^2/x\) and diffuses across the shear layer on a scale \(\nu U/\delta^2\). Balancing them gives \(\delta\sim\sqrt{\nu x/U}\). The ratio \(\delta/x\sim Re_x^{-1/2}\) may be small even though the tangential shear force from the layer matters to the machine. The similarity solution places the 99% speed level near \(5x/\sqrt{Re_x}\), and the local skin-friction coefficient \(\tau_w/(\rho U^2/2)\) near \(0.664/\sqrt{Re_x}\).
Doubling speed at a fixed station multiplies the local Reynolds number by two. The dimensionless friction coefficient falls by \(1/\sqrt2\), but dynamic pressure grows fourfold. The dimensional shear therefore rises by \(2^{3/2}\). This distinction matters when reading plots of nondimensional test results: a lower plotted coefficient can accompany a larger actual force.
Scale a submerged component
A streamlined full-size probe of length 0.60 m moves at 2.0 m/s in water with \(\nu=1.0\times10^{-6}\,\mathrm{m^2/s}\). A geometrically similar third-scale model in the same water needs 6.0 m/s for equal Reynolds number \(1.2\times10^6\). Assume matching surface finish in relative terms, sufficiently small blockage, the same flow regime and no free-surface effect. Then the dimensionless drag \(C_D=F_D/(\rho U^2A/2)\) should agree. Since the model’s reference area is one ninth and its speed squared is nine times as large, its drag is equal to the prototype drag in this example.
If only 2.0 m/s can be reached in the test tank, the model Reynolds number is one third of full size. An observed transition, separation point or drag coefficient may then shift. Document this mismatch rather than scaling the raw measured drag by area alone. Matching a single group does not fix every boundary condition, especially the upstream disturbance level that can trigger transition.
Scale a different experiment with the same geometry
For a one-ninth length model of a surface vessel, matching Froude number requires
In the same water its Reynolds number relative to the prototype is
Exact Froude and Reynolds similarity cannot both hold at that length and speed with the same fluid. Gravity-wave resistance can be compared at matched Froude number, while viscous skin friction needs a separate correction. Report both dimensionless numbers with the measured force and its reference area. That allows a reader to distinguish the physical part of the scaling argument from assumptions used for extrapolation.
Recover a dimensional frequency from a model
Matching a dimensionless frequency can transfer an unsteady effect. For an oscillation of frequency \(f\) in a stream of speed \(U\) past a length \(L\), the Strouhal number is \(fL/U\). A 0.10 m model in a 3 m/s stream oscillating at 6 Hz gives 0.20. If relevant geometry and governing dimensionless parameters are matched, a 0.50 m prototype at 2 m/s would oscillate at \(0.20(2)/0.50=0.80\) Hz. Frequency alone cannot be rescaled by the geometric factor when the reference speeds differ.
Determine when surface tension prevents gravity-wave similarity
A reduced-scale flume can match gravity and inertia by matching Froude number. The air–water interface also has surface tension \(\sigma\). A disturbance with characteristic length \(L\) and speed \(U\) has inertial pressure scale \(\rho U^2\), gravity scale \(\rho gL\), and capillary pressure scale \(\sigma/L\). The ratios produce \(\mathrm{Fr}^2=U^2/(gL)\) and \(\mathrm{We}=\rho U^2L/\sigma\). Dividing the latter by the former gives the Bond number \(\mathrm{Bo}=\rho gL^2/\sigma\). Choosing model speed to match Froude number leaves Bond number determined by geometry and material properties. With the same liquid and gravity, reducing length by ten reduces Bond number by one hundred.
For a more precise test use the small-amplitude, inviscid deep-water dispersion relation \(\omega^2=gk+\sigma k^3/\rho\) for wave number \(k=2\pi/\lambda\). The gravity term arises from surface elevation, while the capillary pressure perturbation is proportional to surface curvature \(k^2\eta\). The ratio of capillary to gravity restoring contributions is \(\sigma k^2/(\rho g)\). Equal contributions occur at wavelength \(2\pi\sqrt{\sigma/(\rho g)}\). The appropriate length in this ratio is \(1/k\); omitting the \(2\pi\) when using wavelength changes the inferred correction substantially.
Check a wave-frequency prediction at two geometric scales
For water use \(\sigma=0.072\,\mathrm{N/m},\ \rho=1000\,\mathrm{kg/m^3}\) and \(g=9.81\,\mathrm{m/s^2}\). The crossover wavelength is
Consider a prototype wave of wavelength 0.40 m. Its wave number is 15.71 m⁻¹ and the capillary-to-gravity ratio is
Its frequency is approximately \(\sqrt{9.81(15.71)(1.00181)}/(2\pi)=1.98\,\mathrm{Hz}\), essentially the gravity prediction.
A geometrically similar one-tenth model uses wavelength 0.040 m, wave number 157.1 m⁻¹ and capillary-to-gravity ratio 0.181. Pure gravity scaling would predict frequency \(\sqrt{10}(1.98)=6.26\,\mathrm{Hz}\). Including capillarity gives \(\sqrt{9.81(157.1)(1.181)}/(2\pi)=6.79\,\mathrm{Hz}\), about 8.5% higher. A frequency discrepancy need not indicate a clock error or a viscosity error. The model has moved into a region where a restoring force previously negligible is perceptible. Deep water also requires \(kh\) large at both scales; shallow flume depth adds a separate \(\tanh(kh)\) factor. Enlarging the model or choosing a different measured observable may be preferable to enforcing incompatible similarity conditions.
A useful comparison can be made by timing wave packets as well as crests. The phase speed is
The group speed of a narrow wave packet follows from differentiating the dispersion relation,
Their ratio is \([1+3B]/[2(1+B)]\), where \(B=\sigma k^2/(\rho g)\). In the prototype example it is 0.502, close to the deep-water gravity value of one half. In the short model it is 0.653. Thus scaling time to match one measured crest frequency still would not make packets travel relative to their crests in exactly the same way. A video showing both individual crest motion and arrival of a packet envelope provides experimental evidence for the altered mechanism.
Surface contamination is another experimental variable: an altered surface tension changes the capillary correction without changing either geometric length or gravity-wave Froude number.
Study the full derivation
Settling spheres, Stokes drag and a wall correction · Momentum, motion and transport in fluids
A falling-sphere viscometer infers viscosity from terminal speed. Derive the drag on a no-slip sphere, distinguish creeping flow from merely steady motion and use radius, vessel width and orientation checks to decide what the speed experiment actually measures.
Problem sheet 3 · Viscous transport and similarity
Derive resistance or a scaling law first, then test that its flow-regime assumptions still apply.
1. Split a laminar flow
Two long circular pipes of the same length connect common manifolds. Their radii are 2 mm and 3 mm and the fluid is the same. (a) Find the flow ratio. (b) Split a total of 6.0 mL/s. (c) If both radii are reduced by 10%, how does the required pressure drop change at fixed total flow?
Apply the common-pressure condition
At equal pressure drop the radius-fourth law gives
Thus \(Q_1=6/(1+5.0625)=0.990\) mL/s and \(Q_2=5.01\) mL/s. Reducing both radii scales each conductance by \(0.9^4\), so the common pressure drop must increase by \(1/0.9^4=1.52\). This assumes both flows remain developed and laminar and manifold losses remain negligible.
2. Compare pressure and wall driving
A 2 mm film of viscosity 0.10 Pa·s is bounded by a fixed lower plate and an upper plate moving at 0.40 m/s. A downstream pressure fall produces \(G=3000\) Pa/m. (a) Find the two contributions to \(Q/b\). (b) Find the midpoint speed. (c) What pressure gradient would produce zero net flux?
Superpose the profiles
The moving-wall and pressure terms are \(UH/2=4.0\times10^{-4}\) and \(GH^3/(12\mu)=2.0\times10^{-5}\) m²/s, totalling 0.00042 m²/s. At the middle, \(u=U/2+GH^2/(8\mu)=0.215\) m/s. To cancel wall transport one needs \(G=-6\mu U/H^2=-60\,000\) Pa/m. The negative sign represents a pressure rise in the direction of plate motion.
3. Design a reduced-scale tow test
A 2 m submerged object is towed at 1.5 m/s in water with \(\nu=10^{-6}\) m²/s. A geometrically similar 0.50 m model is available. (a) Find the required speed for equal Reynolds number in the same water. (b) For equal drag coefficient, compare model and prototype drag. (c) If surface waves dominate instead, find the speed for equal Froude number and the resulting Reynolds-number ratio.
Match a dimensionless balance
Prototype Reynolds number is \(3.0\times10^6\). At quarter length the required model speed is 6.0 m/s. Same density and drag coefficient imply \(F_m/F_p=(6/1.5)^2(0.5/2)^2=1\). Froude matching would require \(1.5\sqrt{0.25}=0.75\) m/s, giving \(Re_m/Re_p=(0.75/1.5)(0.5/2)=1/8\). The choice of matching rule changes the interpretation of the measured drag.
Which pressure difference establishes an accelerating uniform stream?
In the uniform core of a horizontal water test channel let \(u=0.60t\) in SI units for the first two seconds, with negligible transverse velocity and negligible viscous stresses in the core. Two pressure taps sampling the core at the same elevation are 1.50 m apart. Find the material acceleration and the pressure difference, then compare this result at \(t=2\) s with a steady core moving at the same instantaneous speed. Use \(\rho=998\,\mathrm{kg\,m^{-3}}\).
Show the worked solution
Spatial gradients vanish, so the advective term is zero. During the ramp \(Du/Dt=0.60\,\mathrm{m\,s^{-2}}\), hence
Integrating downstream gives \(p_\mathrm{up}-p_\mathrm{down}=898.2\,\mathrm{Pa}\). Both cases have \(u=1.20\,\mathrm{m\,s^{-1}}\) at the instant of comparison. In the steady uniform ideal core the local derivative also vanishes, so the tap difference is zero. A calculation using speed alone could not distinguish them. Actual wall friction, if significant, would demand an additional pressure gradient.
Revisit chapter 5 · How does a local pressure gradient accelerate a fluid particle?.
Explore the governing equations after solving the sheet: Viscous stresses, duct resistance and wall-driven flow; Dynamic similarity, boundary layers and model tests. Compare the assumptions and units before transferring your chosen parameters; the controls may cover a different numerical range from the written exercise.
Chapter 7 · Vorticity, circulation and swirling flow
Distinguish rotation of a fluid element from an orbiting streamline and use radial momentum balance to predict a free-surface shape.
From first principles
Derive vorticity from circulation around a small rectangle
In a smooth planar velocity field write velocity as \((u,v)\) and consider a fixed small rectangle of sides \(dx,dy\). Traverse it counterclockwise and add the component of velocity along each side times the side length. Uniform velocity cancels between opposite sides. A difference in vertical velocity across \(dx\) or horizontal velocity across \(dy\) can leave a net circulation.
Taylor expansion and division by the enclosed area give the local circulation density, or axial vorticity. Adding neighbouring rectangles cancels the internal boundaries and yields the finite-area formula.
For solid-body rotation \(u=-\Omega y\), \(v=\Omega x\), so \(\omega_z=2\Omega\). A fluid element's local angular velocity is half its vorticity. This local rate can vanish even on a curved streamline because the motion of a parcel centre and the deformation around it are different observations.
Background · Vorticity
Its units are reciprocal seconds. Circulation around a closed loop integrates the corresponding vorticity flux when the interior is regular.
Derivation and applications
Reconstruct the core of a vortex from circulation
A vortex in a stirred tank often rotates nearly as a solid body close to its axis and approximately as a potential vortex farther out. Model a steady planar axisymmetric flow with tangential speed \(v_\theta\), no radial velocity, and a circular core of radius \(a\). Choose uniform axial vorticity \(\omega_0>0\) in the core and zero vorticity outside. For a circle of radius \(r\), Stokes' theorem relates the tangential speed to the vorticity integrated over the enclosed disk.
Inside the core the circulation grows with area. Outside it, the entire core is already enclosed, so the same circulation is spread over a larger circumference. The speed is continuous and reaches its maximum at the core radius.
For a horizontal flow of constant density \(\rho\), radial momentum balance gives
Integrate first from the centre to the core radius and then from the core to a distant radius where the swirl has decayed. The two regions make equal contributions to the centre-to-infinity pressure deficit.
The idealised sharp change of vorticity at \(a\) replaces a smooth viscous transition. A finite vessel truncates the exterior integral, so the pressure reference radius must be specified when it lies close to the core.
Worked example
Predict a core pressure deficit
A water vortex has \(a=30.0\) mm and \(\omega_0=40.0\) s⁻¹. The peak tangential speed is 0.600 m/s and its exterior circulation is \(\pi(40.0)(0.0300)^2=0.113\) m²/s. The predicted pressure difference from the centre to distant liquid at the same height is
Half of this rise occurs within the core.
Change the inputs and inspect this calculation below
Second application
Infer the core radius from two speed measurements
A second vortex has speed 0.200 m/s at \(r=10.0\) mm inside the core and 0.250 m/s at \(r=50.0\) mm outside. The inner reading gives \(\omega_0=2(0.200)/0.0100=40.0\) s⁻¹. The outer reading gives \(a=\sqrt{2rv_\theta/\omega_0}=25.0\) mm, between the measuring radii as assumed. Its maximum speed should therefore be 0.500 m/s.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Distinguish a particle orbit from local spin
Drop a small paddle wheel into a swirling tank. Its centre can travel around the tank axis whether or not the wheel itself spins relative to distant reference axes. To measure local rotation, consider two short perpendicular material lines through the same fluid element. In a planar velocity field \((u,v)\), an initially horizontal line rotates at \(\partial v/\partial x\), and an initially vertical line rotates at \(-\partial u/\partial y\), both with counterclockwise positive. Their mean is the local angular velocity, one half the out-of-plane vorticity.
The second relation is Stokes’ theorem. The curve encloses \(A\) with consistent orientation and the velocity must be regular throughout that surface. Circulation is measured in square metres per second. In a region with zero vorticity a closed curve can still enclose a singular or otherwise excluded core; then the area needed for the usual zero-circulation argument does not lie entirely in that region.
Compare two angular velocity distributions
In axisymmetric swirl with only tangential velocity \(v_\theta(r)\), circulation on a circular path is \(2\pi r v_\theta\). Dividing its change between neighbouring rings by the annular area gives
A forced vortex rotates like a rigid body, \(v_\theta=\Omega r\), with vorticity \(2\Omega\). At radius 0.10 m and angular speed 8 rad/s, its velocity is 0.80 m/s and the circular-path circulation is 0.503 m²/s.
In a free-vortex exterior \(v_\theta=K/r\); the vorticity is zero at every regular point there although the streamlines are circular. If its velocity at the same radius is also 0.80 m/s, then \(K=0.080\,\mathrm{m^2/s}\). At radius 0.20 m its speed falls to 0.40 m/s, while in the forced vortex the speed rises to 1.60 m/s. Both flows have the same circulation at the original radius. A second measuring circle distinguishes them without an instrument that directly senses local shear.
Recover pressure and free-surface rise
For steady axisymmetric circular streamlines without radial or vertical motion the radial acceleration points inward with magnitude \(v_\theta^2/r\). Radial momentum balance requires
Vertical equilibrium gives
Along a free surface at uniform ambient pressure their contributions cancel, so \(dz/dr=v_\theta^2/(gr)\). For rigid rotation, integration gives
A cylindrical open tank of radius 0.20 m rotating at 8 rad/s has a predicted wall-to-centre rise of \(64(0.20)^2/[2(9.81)]=0.1305\,\mathrm m\). If no water spills, volume conservation places its former flat level halfway between the new centre and rim elevations for this paraboloid. Each shifts by about 65 mm in opposite directions. A nearly full tank will spill instead, and the average-level constraint then changes. A free vortex produces a different surface profile and its singular axis must be replaced by a physical core.
Construct irrotational flow around a cylinder
Outside a vortex core or boundary layer, a two-dimensional incompressible flow can often be approximated as irrotational. In a simply connected region irrotationality permits a velocity potential with \(\mathbf v=\nabla\phi\), and continuity then requires
For a circular cylinder of radius \(a\) in a uniform stream \(U\) along the positive \(x\) direction, try \(\phi=(Ar+B/r)\cos\theta\). The two radial factors solve Laplace’s equation for the angular first harmonic. Matching the distant uniform potential \(Ur\cos\theta\) gives \(A=U\). No penetration requires radial velocity \(\partial_r\phi=0\) at \(r=a\), giving \(B=Ua^2\).
The boundary has zero normal speed but a nonzero tangential speed. This is consistent with an inviscid slip condition. It does not satisfy the no-slip condition for an actual viscous wall, so predicted surface pressure is meaningful only insofar as outer flow remains attached and nearly irrotational. In a real cylinder wake, separation breaks the fore–aft symmetry of this ideal solution.
Applying steady Bernoulli relative to the uniform upstream stream gives the surface pressure coefficient \(C_p=1-4\sin^2\theta\). Its values change considerably around the cylinder even though integrating the pressure forces yields zero net drag and lift by symmetry. Zero potential-flow drag does not imply uniform pressure.
Add circulation and predict unequal side pressures
A mathematical cylinder excludes its interior from the fluid. Superpose a free-vortex velocity \(\Gamma/(2\pi r)\) in the positive counterclockwise direction; this preserves the no-penetration condition while changing circulation around the body. Its sign adds to the negative surface velocity on one side and opposes it on the other. For a 50 mm radius cylinder in air at \(U=10\,\mathrm{m/s}\), choose \(\Gamma=0.50\,\mathrm{m^2/s}\) counterclockwise. The added surface speed is
At the top the signed tangential speed is −18.41 m/s, and at the bottom it is +21.59 m/s.
For air density 1.20 kg/m³ the dynamic pressure is 60 Pa. The top and bottom coefficients \(1-(v_\theta/U)^2\) are −2.39 and −3.66, respectively. The lower pressure is now at the bottom, producing downward lift. Integrate \(-p\,n_y a\,d\theta\) around the circumference: the terms even between top and bottom cancel, leaving signed lift per span \(L'=-\rho U\Gamma=-6.0\,\mathrm{N/m}\) for these axes. A rigid-body rotation of the entire fluid would give a different vorticity field; the superposed free vortex has zero local vorticity outside the excluded body. Physical circulation in an experiment depends on how the flow and surface boundary layers are established, and cannot be selected by the potential solution alone.
The stagnation points satisfy \(\sin\theta=\Gamma/(4\pi aU)\), or 0.0796 here. They shift by about 4.6° from their zero-circulation positions without changing the fact that pressure is highest where speed vanishes. This offers a second observable for estimating circulation, independent of integrating the measured lift, provided the observed surface points reasonably follow the attached outer-flow model.
Chapter 8 · Boundary layers and momentum thickness
Connect a measured velocity deficit to wall drag and distinguish the physical edge of a boundary layer from its integral thicknesses.
From first principles
Obtain wall drag from the streamwise momentum deficit
A thin boundary layer slows fluid next to a solid wall. Consider steady two-dimensional flow over a smooth flat plate with constant external speed \(U\) and pressure. Use unit span and constant density \(\rho\). Choose a control volume ending at location \(x\), with its upper surface a streamline outside the layer. Mass conservation relates the uniform inlet flow to the downstream velocity profile. Multiplying the discharged mass in a strip by the streamwise speed it has lost gives that strip's contribution to the momentum deficit.
The integrated deficit equals the drag per unit span exerted by the wall on the flow in magnitude. Extending the plate by a small \(dx\) adds wall drag \(\tau_w\,dx\), so differentiating yields
These relations assume negligible pressure gradient. The thickness \(\theta\) weights lost velocity by the mass flux actually present in that part of the profile.
Derivation and applications
Relate displacement thickness to boundary-layer entrainment
Mass conservation requires a weak normal flow at the edge of a developing boundary layer. Consider steady, two-dimensional incompressible flow over an impermeable flat plate with constant external speed \(U\). Let \(u(x,y)\) be tangential velocity, \(v(x,y)\) normal velocity and \(y=0\) the wall. Integrate continuity from the wall to a fixed measurement height \(H\) chosen well outside the layer throughout the region of interest. Since \(v(x,0)=0\),
The integral would equal \(UH\) for a uniform velocity profile. The missing volume flux per unit span defines displacement thickness \(\delta^*\) times \(U\). For constant \(H,U\), differentiating cancels the large uniform part and connects the missing flux directly to the weak external normal velocity.
For an illustrative profile take \(u/U=2\eta-\eta^2\) up to \(\eta=y/\delta=1\) and \(u=U\) above it. Its deficit is \((1-\eta)^2\) and its integral is one third. When \(\delta\) grows as the square root of distance from the leading edge, the normal velocity follows by differentiation.
The sign is positive because the low-speed layer occupies an increasing share of the fixed-height section. The value at fixed external height differs from the mass entering a control surface that itself follows the growing edge.
Worked example
Estimate normal flow above a plate
At \(x=0.500\) m, a measured polynomial layer has \(\delta=6.00\) mm and \(U=4.00\) m/s. If it grows locally as \(\sqrt x\), the predicted edge velocity is
Its ratio to the external tangential speed is only 0.00200. The displacement thickness is 2.00 mm, the height by which a uniform-speed stream would need to be displaced to produce the same missing flux.
Change the inputs and inspect this calculation below
Second application
Use two profiles to infer the average vertical flux
Independent surveys at \(x=0.200\) and 0.600 m find displacement thicknesses 1.20 and 2.00 mm. At \(U=3.00\) m/s the interval-average normal velocity is
Over a plate span of 0.500 m this corresponds to outward volume flow \(0.00600(0.400)(0.500)=1.20\) L/s through the fixed upper face, equal to the growth of the streamwise flux deficit.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Start from this chapter. Balance streamwise advection against diffusion normal to the plate. Predict the thickness scaling, then measure both the 99% thickness and wall-friction coefficient at one specified station.
OneSimulation laboratory · Measure boundary-layer growth from a velocity profile
Viscosity matters where velocity changes rapidly
Flow past a smooth plate with a large length-based Reynolds number often has nearly uniform speed outside a thin layer next to the wall. No slip requires zero velocity at the stationary surface. Inside the thin region, transverse velocity gradients can be large enough for viscosity to balance streamwise inertia. If the free-stream speed is \(U\), the streamwise distance is \(x\) and the layer thickness is \(\delta\), the leading inertial and viscous scales are \(U^2/x\) and \(\nu U/\delta^2\). Their balance gives \(\delta/x\sim1/\sqrt{\mathrm{Re}_x}\), where \(\mathrm{Re}_x=Ux/\nu\).
This scaling predicts how a laminar layer grows. Its numerical factor depends on how the thickness is defined. A common measured edge is the position reaching 99% of the external speed. Two integral measures instead quantify flow displaced by the layer and its lost momentum, and are less sensitive to picking a particular edge point.
The thickness \(\delta^*\) gives the equivalent missing volume flux per unit width divided by \(U\). Momentum thickness \(\theta_m\) weights that deficit by the actual local speed. Fluid right at the wall contributes strongly to displacement thickness but carries almost no streamwise momentum flux.
Relate the momentum deficit to wall shear
A steady control volume surrounding one face of a flat plate at zero incidence receives fluid from the uniform upstream stream. For constant external speed and pressure, the integrated wall force equals the deficit of streamwise momentum flux downstream after accounting for entrained fluid. Per unit plate width this gives
Differentiating gives local wall shear \(\tau_w=\rho U^2\,d\theta_m/dx\). A growing deficit implies positive drag on the plate.
Suppose a velocity survey is represented by \(u/U=2\eta-\eta^2\) for \(0\le\eta=y/\delta\le1\), and uniform flow outside. Integrating yields
Since \(\int_0^1(2\eta-\eta^2)d\eta=2/3\) and \(\int_0^1(2\eta-\eta^2)^2d\eta=8/15\), the momentum thickness is \(2\delta/15\).
Infer drag from a measured layer
At the end of a 0.60 m plate of width 0.40 m in air, let \(U=12\,\mathrm{m/s}\), \(\rho=1.20\,\mathrm{kg/m^3}\) and \(\delta=5.0\,\mathrm{mm}\) according to the fitted profile. Then \(\theta_m=0.667\,\mathrm{mm}\) and drag on the measured face is
The mean shear over that face is
It need not equal the local shear at the measuring station. An adverse pressure gradient or separated flow changes the momentum balance; surface pressure forces and external acceleration must then be included before interpreting a wake or boundary-layer survey.
Predict a boundary-layer thickness before viewing a simulation
At the same measuring station the laminar scaling from the first section gives \(\delta\propto\sqrt{\nu/U}\). Starting from a measured 35.84 mm layer at \(x=0.50\) m, predict its thickness after separately doubling free-stream speed and doubling kinematic viscosity. Which change should raise the dimensional wall stress if density and viscosity are held fixed while speed increases? Compare your thickness ratios with the two computed runs and distinguish the measured skin-friction coefficient from wall stress in pascals. Compare the flat-plate runs.
Reduce a partial differential equation to one similarity profile
For a laminar zero-pressure-gradient boundary layer along a flat plate, the leading equations are \(u_x+v_y=0\) and \(u u_x+v u_y=\nu u_{yy}\). Assume external speed \(U\) constant, a stationary no-slip surface and a layer thin relative to streamwise distance. Introduce a streamfunction \(\psi\) through \(u=\psi_y,\ v=-\psi_x\) to satisfy continuity identically. The scaling \(\delta\sim\sqrt{\nu x/U}\) suggests \(\eta=y\sqrt{U/(\nu x)}\) and \(\psi=\sqrt{\nu Ux}\,f(\eta)\). Differentiation gives \(u=U f'\) and \(v=\tfrac12\sqrt{\nu U/x}(\eta f'-f)\).
When these forms enter the momentum equation, the terms containing \(\eta f'f''\) from longitudinal and transverse advection cancel. Both the remaining inertial and viscous terms carry \(U^2/x\). Dividing through gives the Blasius boundary-value problem
The two wall conditions impose zero normal and tangential velocity. The outer condition matches the uniform stream. The unknown wall slope of the velocity profile, \(f''(0)\), is determined by matching that distant condition; prescribing it independently would overdetermine the third-order equation. Numerical integration gives approximately 0.3321 for this definition of \(\eta\). Conventions that include a factor of two in the similarity coordinate assign a different numerical constant but the same physical wall stress.
Predict a force measurement from the similarity solution
The wall shear is \(\mu U f''(0)\sqrt{U/(\nu x)}\), giving \(c_f(x)=\tau_w/(\rho U^2/2)=0.664/\sqrt{\mathrm{Re}_x}\). Its integral over a plate of length \(L\) yields mean coefficient \(\bar c_f=1.328/\sqrt{\mathrm{Re}_L}\). The mean equals twice the local trailing-edge value because the integrable \(x^{-1/2}\) shear is highest near the leading edge. Using a single trailing-edge wall gauge for the whole area would therefore underestimate the force.
Take a smooth plate 0.50 m long and 0.25 m wide in air at \(U=6.0\,\mathrm{m/s},\ \nu=1.5\times10^{-5}\,\mathrm{m^2/s},\ \rho=1.20\,\mathrm{kg/m^3}\). The trailing-edge Reynolds number is 200,000, and a nominally laminar calculation gives
The one-face drag is
The trailing-edge wall shear is just 0.0321 Pa, and the 99% thickness estimate \(5L/\sqrt{\mathrm{Re}_L}\) is 5.59 mm. A support carrying both plate faces would register roughly twice the one-face drag if both flows are comparable, plus fixture and edge drag. A single net force measurement cannot by itself tell whether a discrepancy arose from transition, unequal face conditions or the support geometry.
The similarity solution also predicts how to collapse profiles measured at different stations. At \(x=0.125\) m the same value of \(\eta\) corresponds to half the wall-normal distance it does at 0.50 m, since the distance scales with \(\sqrt{x}\). Meanwhile wall shear doubles and local skin-friction coefficient doubles. A traverse resolving only whole millimetres may describe the outer velocity defect at both positions but badly estimate the near-wall slope at the earlier one. Testing both the profile collapse and the independent integral drag provides a stronger check of the assumed laminar flow than comparing a single velocity at the outer edge.
Measure the momentum transported by turbulent fluctuations
In a smooth plane channel driven by a constant pressure drop, time averaging can hide the dominant transport mechanism. Consider steady statistics and a fully developed mean flow between parallel walls. Let \(y=0\) denote the lower wall and \(h\) the distance to the centreline. Write \(u=U(y)+u'\), \(v=v'\). Impermeability and incompressibility give zero mean transverse velocity. The average of the instantaneous flux of streamwise momentum across a horizontal surface is nevertheless \(\rho\overline{uv}=\rho\overline{u'v'}\). Averaging the product retains the correlation between the two fluctuations.
For constant density and viscosity the mean streamwise balance becomes
Set \(G=-d\bar p/dx>0\). Integrating from \(y\) to the centreline, where symmetry sets the total shear to zero, gives
The right side is fixed by the driving pressure gradient. At a no-slip wall both fluctuating velocities vanish, so molecular viscosity carries the full shear there. Farther out a parcel moving rapidly downstream can move towards the lower wall (\(u'>0,\ v'<0\)). A slow parcel leaving that wall has the same negative product. Both transfer streamwise momentum towards the wall. With the signs above the turbulent contribution to the shear is positive.
For water with \(\rho=1000\) kg/m³ and \(\mu=0.0010\) Pa s, take \(h=0.020\) m and \(G=100\) Pa/m. The wall stress is 2.00 Pa. At \(y=0.0050\) m the total shear is 1.50 Pa. A measured slope of \(150\) s⁻¹ accounts for 0.150 Pa. The remaining 1.35 Pa implies \(\overline{u'v'}=-1.35\times10^{-3}\) m²/s². The exact force balance gives a quantitative consistency check for velocity measurements or a simulation. Predicting the split from \(G\) alone would require a relation for the velocity correlations.
Practise on sheet 4 · Test a turbulent channel measurement. Further reading · University of Iowa · ME:7268 Turbulent Flow · Chapter 8, part 1 · Channel flow, Reynolds stress and force balance.
Estimate a boundary layer’s momentum deficit
Momentum thickness is \(\theta=\int(u/U)(1-u/U)\,dy\). Use three idealised trial profiles at the same outer thickness. Integrating the ordinate with respect to the plotted dimensionless height gives \(\theta/\delta\).

Read values from the plot
| Distance from wall / layer thickness | Linear velocity profile | Quadratic velocity profile | One-seventh-power profile |
|---|---|---|---|
| 0 | 0 | 0 | 0 |
| 0.25 | 0.1875 | 0.24609 | 0.14739 |
| 0.5 | 0.25 | 0.1875 | 0.085388 |
| 0.75 | 0.1875 | 0.058594 | 0.038643 |
| 1 | 0 | 0 | 0 |
Interactive calculation · change the inputs of this example
Change the exponent of the trial velocity profile. Equal endpoint velocities need not imply equal momentum deficit.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.
Study the full derivation
Estimate wall drag by integrating a boundary-layer profile · Momentum, motion and transport in fluids
A velocity probe can resolve the momentum missing from a boundary layer more easily than the wall shear itself. Derive an integral momentum relation, estimate drag using a polynomial profile and determine when a pressure gradient or a measurement too far from the wall changes the answer.
Problem sheet 4 · Swirling flows and wall drag
Use a velocity distribution to infer local vorticity, pressure differences and the momentum lost to wall drag.
A rigidly spinning tank
Water in an open cylindrical tank of radius 0.15 m rotates as a solid body at 6 rad/s. Determine the circulation around the rim, local vorticity and wall-to-centre free-surface rise. Compare the vorticity with that of an ideal free-vortex exterior carrying the same circulation.
Reveal the worked solution
The rim speed is \(6(0.15)=0.90\,\mathrm{m/s}\) and circulation is
The vorticity is \(2\Omega=12\,\mathrm{s^{-1}}\). Integrating the radial and vertical pressure balance gives
A free vortex of the same circulation has zero local vorticity outside its core. The circulation measures what the loop encloses.
A linear layer profile
An idealised velocity survey gives \(u/U=y/\delta\) to the layer edge and unity above. Derive displacement and momentum thicknesses. For \(U=8\,\mathrm{m/s}\), water density 1000 kg/m³, \(\delta=2\,\mathrm{mm}\) and plate width 0.15 m, estimate drag on the surveyed face to this station.
Reveal the worked solution
Integrating \(1-\eta\) gives
Integrating \(\eta(1-\eta)\) gives
Under constant external pressure and speed,
Only the one face to which the survey applies has been counted.
Infer a local shear stress
A measured zero-pressure-gradient momentum thickness follows \(\theta_m=0.0010\sqrt{x/(1\,\mathrm m)}\,\mathrm m\). Air density is 1.2 kg/m³ and external speed 15 m/s. At \(x=0.25\,\mathrm m\), find local wall shear and integrated drag per unit width. Why do these two quantities have different units?
Reveal the worked solution
At the station \(\theta_m=0.00050\,\mathrm m\) and \(d\theta_m/dx=0.0010\). Local shear is
Drag per width is
Local shear is force per area; integrating along plate length removes one inverse length.
Test a turbulent channel measurement
A water channel has half-height 15 mm and pressure gradient \(-80\) Pa/m. At a probe 5 mm from the lower wall, measurements give \(dU/dy=100\) s⁻¹ and \(\overline{u'v'}=-5.0\times10^{-4}\) m²/s². Use \(\rho=1000\) kg/m³ and \(\mu=0.0010\) Pa s. How well do the measurements close the momentum balance? What correlation would close it at the stated position?
Worked solution
The expected total stress is
The gradient gives 0.10 Pa and the measured covariance gives another 0.50 Pa. Together these account for 0.60 Pa. The shortfall is 0.20 Pa, or 25% of the pressure-based stress at the probe. The wall stress of 1.20 Pa is a different comparison value.
Holding the gradient fixed gives \(\overline{u'v'}=-(0.80-0.10)/1000=-7.0\times10^{-4}\) m²/s². Before changing a turbulence model, check the probe height, the averaging interval and whether the flow is fully developed. Changing the sign convention for just one term cannot resolve the shortfall.
Revisit chapter 8 · Measure the momentum transported by turbulent fluctuations.
Explore the governing equations after solving the sheet: Vorticity, circulation and swirling flow; Boundary layers and momentum thickness. Compare the assumptions and units before transferring your chosen parameters; the controls may cover a different numerical range from the written exercise.
Infer viscosity from the edge of a boundary layer
Using the baseline 99% thickness 35.84 mm at \(x=0.50\) m and speed 1 m/s, calibrate the coefficient of \(\delta=C\sqrt{\nu x/U}\) at \(\nu=10^{-4}\) m²/s. At the same station and speed a different run gives 51.03 mm. Infer its kinematic viscosity without measuring a wall gradient. Compare it with the input and identify one reason for a discrepancy.
Work through the solution
The baseline gives
At common \(x,U\), the coefficient cancels in the ratio, so \(\nu_2=10^{-4}(51.03/35.84)^2=2.03\times10^{-4}\) m²/s. The laboratory input was \(2.00\times10^{-4}\) m²/s. The similarity argument describes an ideal laminar layer. Estimating its edge from a discretised velocity profile also depends on interpolation at 99% of the free-stream velocity.
Vary the corresponding laboratory reference interactively. Compare the recalculated observable with the recorded OneSimulation runs and the approximation used in this exercise.
Chapter 9 · Pressure integration, lift and drag
Resolve pressure and shear into integrated forces and infer drag independently from a far-wake velocity survey.
From first principles
Resolve measured surface tractions into lift and drag
Choose a closed surface on a body and a unit normal \(\mathbf n\) pointing from solid into fluid. Pressure acts inward on the body. Viscous stress acts along or normal to the surface depending on the flow. For fluid stress tensor \(-pI+\boldsymbol\tau\), the total fluid force on the body is the sum of all local tractions times surface area.
Here \(\mathbf e_D\) points along the incident stream and \(\mathbf e_L\) is the chosen transverse lift direction. A constant pressure reference can be subtracted because the normal integrates to zero over a closed surface. For a thin wing strip at small slope, upper and lower pressure contributions to lift reduce to their difference integrated over projected area.
The last expression assumes uniform spanwise loading and negligible viscous contribution to lift. Estimating drag can require the small axial components of pressure and the wall shear that this lift approximation omits.
Derivation and applications
Determine the aerodynamic centre of pressure from surface data
A net lift measurement does not say where the load acts. Consider a thin two-dimensional panel of chord \(c\) and span \(b\) in steady flow of dynamic pressure \(q\). Let \(\xi=x/c\) increase from the leading edge and \(\Delta C_p(\xi)\) be lower minus upper pressure coefficient. Assume small surface slopes and neglect shear and end effects so that each strip exerts a vertical force. Define moment as positive for an upward load acting aft of the leading edge. The integrated force and moment are
The centre of pressure \(x_{\rm cp}\) replaces the distributed forces by one force with the same moment. When the total force is nonzero, dividing the two integrals eliminates dynamic pressure and span.
For a linear distribution \(\Delta C_p=A+B\xi\), perform both elementary integrations. A constant increment to the pressure distribution acts at mid-chord and can move the centre even as the original pressure gradient stays unchanged.
Near zero net lift the position ratio can become very large. In that situation a force and a moment about a specified structural axis remain meaningful even when replacing them by one force is inconvenient.
Worked example
Place the resultant from a triangular pressure trace
Let \(A=1.20\), \(B=-1.20\), \(c=0.400\) m, \(b=1.00\) m and \(q=200\) Pa. Lift is \(200(1)(0.400)(0.600)=48.0\) N. Its moment is \(200(1)(0.400)^2(0.200)=6.40\) N m. Hence \(x_{\rm cp}=6.40/48.0=0.133\) m, exactly one third of the chord from the high-pressure-difference end.
Change the inputs and inspect this calculation below
Second application
Recognise a pure couple in a loading test
A second panel has \(A=1.00\), \(B=-2.00\), \(q=300\) Pa, \(b=0.800\) m and \(c=0.500\) m. Positive and negative contributions cancel in the lift integral, giving zero total lift. The moment coefficient is \(1/2-2/3=-1/6\) and the moment is \(-10.0\) N m. A force transducer alone would miss this load; two separated vertical reactions can balance the measured couple.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Start from this chapter. The local wall shear is proportional to dynamic pressure times the local friction coefficient. Test how doubling speed can increase shear even while the dimensionless coefficient falls.
OneSimulation laboratory · Measure boundary-layer growth from a velocity profile
Build the resultant from surface measurements
A wind tunnel balance reports force components along and across the incoming flow. A pressure tap reports only local pressure. To connect the two, draw the surface outward normal from the solid into the fluid. A pressure load then acts on the solid in direction \(-n\); fluid wall shear acts tangentially. Integrate pressure traction and shear traction over the body and project the result onto drag and lift axes. A uniform ambient pressure integrates to zero on a closed surface, so gauge pressure is sufficient for this calculation.
For a thin wing at small incidence the upper and lower surfaces are almost horizontal. To leading order the upward pressure force is the planform integral of \(p_{\rm lower}-p_{\rm upper}\). With dynamic pressure \(q_\infty=\rho U^2/2\), define \(C_p=(p-p_\infty)/q_\infty\). For rectangular planform and a pressure difference independent of span, the lift coefficient is approximately
The reference area \(S\) must be stated. A coefficient based on wing planform and a bluff-body coefficient based on frontal area cannot be compared as if they used the same force scale.
Integrate a pressure distribution
A wing panel has chord 0.30 m and span 0.80 m. Take the pressure-coefficient difference as a triangle, rising linearly from zero at the leading edge to 1.20 at \(x/c=0.25\) and decreasing linearly to zero at the trailing edge. The coefficient integral is the area under this triangle, \(C_L=0.60\). At \(U=20\,\mathrm{m/s}\) in air of density 1.20 kg/m³, \(q_\infty=240\,\mathrm{Pa}\). The estimated lift is \(240(0.24)(0.60)=34.56\,\mathrm N\).
For this spanwise-uniform distribution the centre of pressure follows from the first moment of the triangle. Its chord fraction is the mean of the three vertex abscissae, \((0+0.25+1)/3=0.4167\). The resultant acts about 0.125 m aft of the leading edge. The moment magnitude about that edge is \(34.56(0.125)=4.32\,\mathrm{N\,m}\). Two panels with the same total lift can therefore transmit different support moments if their pressure distributions differ.
Recover a drag force without surface taps
For a survey far enough downstream that static pressure has returned to the external value, integrate the streamwise momentum deficit across the wake. With essentially parallel flow, constant density and negligible outer boundary shear, drag per unit span is \(D'=\rho\int u(U-u)\,dy\). This momentum survey includes the effect of both body pressure and surface shear.
For a simplified wake 40 mm thick with uniform \(u=16\,\mathrm{m/s}\) inside it and \(U=20\,\mathrm{m/s}\) outside, the inferred drag per span is \(1.20(16)(4)(0.040)=3.07\,\mathrm{N/m}\). Replacing the product by \(\rho U(U-u)\) overestimates the deficit because it assigns the undisturbed mass flux to the wake. A survey close to the trailing edge often also needs a static pressure correction; insufficient lateral coverage can miss part of the deficit.
Relate finite-span lift to a second contribution to drag
A pressure integration on one two-dimensional section neglects a feature of every finite lifting surface. Bound circulation changes along the span and trailing vorticity produces downwash behind the wing. For attached lifting-line flow at small angles, downwash tilts the effective incoming stream downward by induced angle \(\alpha_i\). The section’s aerodynamic force is approximately perpendicular to that local stream, so its projection along the original incoming direction creates induced drag \(D_i\simeq L\alpha_i\). This contribution can remain even for an inviscid outer flow because momentum is carried away in a three-dimensional trailing wake.
For elliptical span loading the ideal lifting-line result is
where aspect ratio \(AR=b^2/S\), span \(b\) and planform area \(S\). A span efficiency factor \(e\) accounts approximately for a non-elliptic distribution at a given lift, giving \(C_{D,i}=C_L^2/(\pi e AR)\). With a locally constant parasite coefficient \(C_{D,0}\), total drag at fixed required lift \(W\) becomes
At low speed the necessary lift coefficient rises and induced drag dominates; at high speed parasite drag rises with dynamic pressure. Differentiating \(D\) with respect to \(qS\) gives minimum drag where the two terms are equal. Thus \(C_{L,\rm opt}=\sqrt{\pi e AR C_{D,0}}\). This optimum maximises lift-to-drag ratio for the adopted polar. Minimum power \(DU\) is a different operating point.
Select a glide speed and check the angle assumptions
A small unpowered survey glider has weight 120 N, area 1.20 m² and span 3.0 m. Use density 1.20 kg/m³, \(e=0.80\) and \(C_{D,0}=0.025\). Assume shallow steady glide so lift is approximately weight. Aspect ratio is
The optimum lift coefficient is
From \(W=qSC_L\) the dynamic pressure is 145.8 Pa and the airspeed is
At this condition total drag coefficient is
Drag is 8.75 N, giving \(L/D=13.7\) and glide angle approximately \(\arctan(1/13.7)=4.17^\circ\). The assumption \(L\simeq W\) is consistent to better than one percent. Doubling speed at unchanged weight reduces \(C_L\) by four, so induced drag falls by four while parasite drag rises by four. The original 4.38 N contributions become about 1.09 and 17.5 N. If an estimated optimum lies at or beyond the measured stall coefficient, the attached-flow polar and lifting-line argument no longer support that speed decision.
Banking the same glider changes the required lift. In a coordinated near-level turn with bank angle \(\phi\), the vertical lift component must support the weight, so \(L=W/\cos\phi\). At 45° bank the required lift rises by \(\sqrt2\). At unchanged speed the induced portion of drag then doubles, while the parasite portion is approximately unchanged under the same polar. This transfer calculation explains why a straight-flight drag estimate cannot be inserted unchanged into a turning-flight performance prediction.
The required lift coefficient at the higher bank angle must still remain inside the measured unstalled polar.
Settling in the creeping-flow limit
A small tracer bead in a viscous liquid can reach a regime in which inertial forces on the surrounding liquid are negligible. Estimate their ratio to viscous forces using \(Re_d=\rho U(2a)/\mu\), with radius \(a\). For \(Re_d\ll1\), the steady incompressible equations outside a sphere reduce to \(\nabla p=\mu\nabla^2\mathbf u\) and \(\nabla\cdot\mathbf u=0\). Apply no slip at the sphere and uniform speed \(U\) far away. Linearity then requires drag proportional to \(U\).
The coefficient comes from surface traction. Fix the sphere in flow directed along positive \(z\), and measure polar angle \(\theta\) from that axis. The Stokes solution gives surface pressure relative to the far field \(-3\mu U\cos\theta/(2a)\) and tangential shear \(-3\mu U\sin\theta/(2a)\). The normal viscous stress vanishes there. Project pressure and shear onto the flow direction and use the area of a ring, \(2\pi a^2\sin\theta\,d\theta\). The pressure integral uses \(\int_0^\pi\cos^2\theta\sin\theta\,d\theta=2/3\), while the shear integral uses \(\int_0^\pi\sin^3\theta\,d\theta=4/3\). The two contributions are \(2\pi\mu aU\) and \(4\pi\mu aU\). Even in this highly viscous regime, pressure accounts for one third of the drag.
A spherical calibration bead settles far from the container walls. At terminal speed its apparent weight equals \(6\pi\mu aU_t\), so
For \(a=0.200\,\mathrm{mm}\), \(\rho_s=1250\), \(\rho=1000\,\mathrm{kg\,m^{-3}}\), and \(\mu=0.100\,\mathrm{Pa\,s}\),
The resulting \(Re_d=0.000872\) justifies dropping convective inertia. After terminal speed is reached, 10 mm takes about 45.9 s. Doubling the radius at the same density difference quadruples speed and multiplies \(Re_d\) by eight. A size change therefore merits a fresh check on the approximation.
Practise on sheet 5 · Measure viscosity with a falling calibration bead. Further reading · Georgia Institute of Technology · PHYS 4421 course reading, B. Lautrup, Physics of Continuous Matter · Chapter 20, §20.2 Stokes’ solution for a sphere.
Study the full derivation
Settling spheres, Stokes drag and a wall correction · Momentum, motion and transport in fluids
A falling-sphere viscometer infers viscosity from terminal speed. Derive the drag on a no-slip sphere, distinguish creeping flow from merely steady motion and use radius, vessel width and orientation checks to decide what the speed experiment actually measures.
Chapter 10 · Pump curves, pipe networks and operating points
Construct a hydraulic system curve and solve the operating point of a pump connected to serial or parallel flow paths.
From first principles
Find pump discharge by matching added and required head
A pump supplies head that depends on its discharge and speed. The connected pipework requires head to overcome both terminal elevation or pressure differences and losses. Consider steady incompressible flow between large reservoirs with negligible endpoint velocities. For a fixed pump speed, conservation of mechanical energy at the operating point gives
For fittings and pipe sections with approximately constant loss coefficients, each loss varies as \(V^2/(2g)\). In a single series path all sections carry the same \(Q\), with \(V_j=Q/A_j\). Adding the individual losses gives a system coefficient \(K\).
If the measured pump characteristic is approximated by \(H_p=H_0-aQ^2\), solve the intersection explicitly on the positive-flow branch.
This solution needs \(H_0>H_{\rm static}\). Branches in parallel share an endpoint head difference and their discharges add; those constraints must be imposed before using an equivalent system curve.
Derivation and applications
Find the sensitivity of a pump operating point to a valve
A pump curve and a system curve determine their intersection. Their local slopes also determine how far that intersection moves when a valve setting changes. Model a fixed-speed pump by \(H_p=H_0-aQ^2\) and a network by \(H_s=H_z+bQ^2\) in the intended flow direction. Here \(H_z\) is a static elevation or pressure head, \(a,b>0\) have units of head per squared discharge, and \(H_0>H_z\). The loss model assumes an approximately constant turbulent loss coefficient in the examined flow range.
Differentiate implicitly with respect to the network coefficient at fixed speed and static head. A larger loss coefficient raises the system curve and reduces discharge. The fractional sensitivity is weaker when the pump itself has a steep characteristic.
The actual head delivered by the pump changes as the flow moves along its curve. Differentiating the pump head with the result just obtained gives a positive slope with respect to \(b\), an effect distinguishable by measuring both flow and pressure.
These derivatives apply to small changes. Near zero available head a fractional uncertainty in the difference \(H_0-H_z\) can dominate, even if the separate head measurements are quite accurate.
Worked example
Predict the effect of throttling a circulation line
Measure \(Q\) in L/s and head in metres. Take \(H_0=20.0\), \(H_z=4.00\), \(a=0.250\) and \(b=0.750\) in consistent units. The flow is 4.00 L/s and pump head is 16.0 m. A ten-percent increase in \(b\) predicts \(-3.75\) percent flow by the derivative, or 3.85 L/s. The exact new flow is \(\sqrt{16/1.075}=3.86\) L/s, close to the linear estimate.
Change the inputs and inspect this calculation below
Second application
Infer which curve limits adjustability
At a separate operating point the measured logarithmic flow sensitivity to the total network coefficient is \(-0.100\). This implies \(b/(a+b)=0.200\) and therefore \(a=4b\). A reduction of \(b\) by 20.0 percent at fixed available head changes flow by the exact factor \(\sqrt{5/4.8}=1.0206\). The small 2.06 percent increase quantifies why a noticeable valve change can have little effect on discharge.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Why a pump does not prescribe a unique flow
A centrifugal pump at fixed speed can deliver different combinations of flow and head. The connected network selects an operating point by requiring the head gained through the machine to match the static lift and losses elsewhere. For two large reservoirs, surface speeds are negligible and equal surface pressures cancel. A steady mechanical energy balance then gives
With turbulent pipe resistance represented locally by constant loss coefficients, the losses can be written \(h_L=KQ^2\) for positive flow.
This quadratic law is an approximation over a specified operating range. It follows because fittings and pipe friction have head losses proportional to velocity squared when the relevant coefficients vary little. In laminar pipe flow, the pressure loss at fixed viscosity is instead proportional to flow. A system curve extrapolated far outside its underlying Reynolds-number range can give a misleading operating point.
OneSimulation · When does reducing pump speed close the check valve?
An ideal check valve connects a pump to an open reservoir above its inlet. Let \(n\) denote the speed divided by its reference value and let \(Q\) be measured in litres per second. The pump supplies \(20n^2-0.025Q^2\) metres of head. The pipe and reservoir require \(H_s+0.075Q^2\) metres. Forward flow requires a positive intersection.
OneSimulation inverts the total dynamic loss over the forward-flow interval. With a 5 m static lift, half speed just balances gravity at zero delivery. At reference speed the pump delivers 12.25 L/s. At three-quarter speed it delivers 7.91 L/s, considerably below three quarters of the reference delivery. Beneath the threshold the closed valve carries the pressure difference; the forward-flow equation no longer applies.
"""Intersect a pump curve with a pipe-system head curve at two lifts."""
import matplotlib.pyplot as plt
import numpy as np
from onesim.numerics.nonlinear.kernels.local_solvers.inversion.bracketed_inverse import bisect_increasing
speed = np.linspace(0.25, 1.2, 181) # fraction of reference speed
shutoff = 20. * speed**2 # pump shutoff head in m
pump_loss, pipe_loss = 0.025, 0.075 # m per (L/s)²
fig, ax = plt.subplots(figsize=(7, 4), constrained_layout=True)
for lift, colour in [(0., "#19596a"), (5., "#a5442e")]:
available = shutoff - lift
delivery = np.zeros_like(speed)
active = available > 0
def total_loss(flow):
return (pump_loss + pipe_loss) * flow**2
delivery[active] = bisect_increasing(total_loss, available[active], 0., 30.)
assert np.allclose(shutoff[active] - pump_loss*delivery[active]**2,
lift + pipe_loss*delivery[active]**2)
ax.plot(speed, delivery, color=colour, label=f"Static lift {lift:g} m")
ax.axvline(0.5, color="0.45", linestyle=":", label="5 m lift threshold")
ax.set(xlabel="Pump speed / reference speed", ylabel="Forward delivery (L/s)")
ax.legend()
fig.savefig("fluid-mechanics.png", dpi=170)

Change the inputs of this exact example and compare the recalculated curves with the recorded OneSimulation output above. The browser evaluates the stated analytical or modal reference.
Combine resistances by their physical constraints
In series the same flow passes through each component and head losses add. Thus two quadratic loss coefficients combine as \(K_s=K_1+K_2\). Parallel branches between the same nodes have equal head loss while their flow rates add. For two branches with forward flow, \(Q_i=\sqrt{h/K_i}\), giving
A second identical branch divides the flow equally and reduces the quadratic coefficient of that section to one quarter of the single-branch value. Any upstream or downstream common pipe is still in series with the equivalent section and carries total flow.
Open a parallel return line
Use \(Q\) in litres per second and head in metres. A pump has \(H_p=30-0.20Q^2\); two open reservoirs differ in elevation by 6 m. Initially one pipe connects them with loss \(0.40Q^2\). Equating the heads gives \(30-0.20Q^2=6+0.40Q^2\), so \(Q=\sqrt{40}=6.32\,\mathrm{L/s}\) and \(H_p=22.0\,\mathrm m\). Hydraulic power delivered to water is
Now add a second identical parallel pipe over the whole route. The system curve becomes \(6+0.10Q^2\). The new flow is \(\sqrt{80}=8.94\,\mathrm{L/s}\) and pump head 14.0 m. Each pipe takes only 4.47 L/s, less than the original single-pipe flow. Total delivery increases by about 41% while hydraulic power falls to 1.23 kW. The input shaft power also depends on the efficiency at each operating point. If a flow controller holds the original delivery after the second branch opens, its valve or speed controller changes the operating curve and the free-running comparison no longer predicts the duty.
Determine which side of a branch controls the flow
A check valve on a return line permits only positive branch flow. If an added elevated reservoir imposes a static threshold of 5 m on that branch, the forward branch law becomes \(Q_b=\sqrt{(H-5)/K_b}\) only for driving head \(H>5\) m. Below that threshold the flow is zero. The resulting system curve changes form as the valve opens, so a single constant equivalent coefficient cannot describe both regimes.
Derive the first pressure change in a rapidly closed line
The operating point of a pump and pipe network is a steady state. A valve closure can generate a much higher transient pressure while the flow far upstream has barely changed. Consider a straight horizontal liquid-filled pipe of area \(A\) and initially uniform forward speed \(V\). A rapid downstream closure sends a compression wave upstream at wave speed \(a\). During a short interval \(dt\), the wave reaches approximately \(a\,dt\) of pipe, bringing the fluid behind it to rest. Neglect friction over this short wavefront and take \(a\gg V\).
The stopped mass is \(\rho A a\,dt\), losing momentum \(\rho A a\,dt\,V\). The pressure difference across the front supplies an impulse \(A\Delta p\,dt\). Balancing magnitudes yields the Joukowsky rise \(\Delta p=\rho a V\); for a partial rapid speed change use its magnitude \(\rho a|\Delta V|\) with sign determined by whether the wave compresses or relieves the pipe. Small fluid compressibility and wall compliance both enter the actual wave speed. In a rigid tube \(a\simeq\sqrt{K/\rho}\), but an expanding elastic pipe stores some of the volume change and lowers that speed.
Reflections matter after the wave has travelled to a boundary and back. For a reservoir a distance \(L\) away the first round-trip time is approximately \(2L/a\). A valve that completes closure before the returning wave acts can produce the full first rise. A much slower closure allows incoming reflections to alter the pressure during the manoeuvre and requires a time-dependent network calculation.
Compare closure schedules against a pressure allowance
A water line is 300 m long with measured wave speed \(a=1000\,\mathrm{m/s}\), initial speed 1.5 m/s, density 1000 kg/m³ and initial valve gauge pressure 0.40 MPa. Rapid full closure predicts \(\Delta p=1000(1000)(1.5)=1.50\,\mathrm{MPa}\), bringing the first local peak to about 1.90 MPa gauge. A valve closing in 0.15 s completes its action well inside the 0.60 s round-trip interval. A static energy estimate based only on \(\rho V^2/2=1.13\,\mathrm{kPa}\) would miss the pipe-length momentum transient by orders of magnitude.
Suppose an operating specification allows a first-wave rise of 0.45 MPa. The maximum abrupt decrement in line speed consistent with it is
This provides a useful bound on a single rapid speed change. Dividing the full stop into several identical steps does not automatically satisfy the total pressure limit: reflected waves can add if the steps are poorly timed. A proposed 3 s controlled closure is slow compared with \(2L/a\), so the full instantaneous formula no longer estimates its actual peak. Model the valve characteristic, boundary reflections, pump coast-down and possible sub-atmospheric pressure before choosing a schedule. Measuring pressure at the valve and a second station allows wave speed to be identified from the arrival-time difference.
Calculate a pipe resistance from roughness and flow rate
For fully developed turbulent flow in a round pipe the pressure gradient depends on both the roughness height and the viscous scale of the near-wall flow. Force balance on a length \(L\) gives
Define the Darcy factor by \(f_D=8\tau_w/(\rho U^2)\), where \(U\) is the cross-sectional mean velocity. Combining the equations gives
Use the same Darcy convention throughout. The Fanning factor is \(f_D/4\).
For a straight, uniform, turbulent pipe the empirical Colebrook equation relates \(f_D\) to \(Re=UD/\nu\) and equivalent sand roughness \(\epsilon/D\). Setting \(x=1/\sqrt{f_D}\) turns the implicit equation into a simple iteration:
When roughness dominates the second term, the friction factor becomes nearly independent of Reynolds number. The smooth limit retains a Reynolds-number dependence. For fully developed laminar flow the separate law \(f_D=64/Re\) applies. Near transition a roughness estimate and a single turbulent curve alone cannot resolve the flow regime.
A building cooling loop carries \(Q=4.00\,\mathrm{L\,s^{-1}}\) of water through \(L=40.0\,\mathrm m\) of straight pipe with \(D=50.0\,\mathrm{mm}\), \(\nu=1.00\times10^{-6}\,\mathrm{m^2\,s^{-1}}\) and \(\epsilon=0.050\,\mathrm{mm}\). Continuity gives \(U=4Q/(\pi D^2)=2.037\,\mathrm{m\,s^{-1}}\) and \(Re=1.019\times10^5\). Starting at \(x_0=7\), iteration converges to \(x=6.721\), hence \(f_D=0.02214\) and \(h_f=3.75\,\mathrm m\). If deposits raise equivalent roughness to \(0.200\,\mathrm{mm}\) at unchanged bore and flow, the same calculation gives \(f_D=0.02948\) and \(h_f=4.99\,\mathrm m\). Thus the pump needs 1.24 m additional head for this pipe segment alone. At fixed pump speed the operating flow would generally change. That requires solving the pump and system curves together.
Practise on sheet 5 · Infer an equivalent roughness from two pressure taps. Further reading · Purdue University · ME 30900 Introduction to Fluid Mechanics · Pipe Flows – Pipe Systems, “Colebrook Formula” and the Moody plot.
Read the new operating point after throttling
Approximate a pump curve and the piping resistance by parabolas in flow measured in litres per second. Static lift is 6 m. Throttling raises the coefficient of the flow-squared loss, while speed and pump geometry stay fixed.

Read values from the plot
| Volume flow (L/s) | Pump curve | Open system | Throttled system |
|---|---|---|---|
| 0 | 32 | 6 | 6 |
| 8.6667 | 30.648 | 7.0516 | 8.704 |
| 17.5 | 26.488 | 10.287 | 17.025 |
| 26.333 | 19.518 | 15.708 | 30.964 |
| 35 | 9.95 | 23.15 | 50.1 |
Interactive calculation · change the inputs of this example
Throttle by increasing the system coefficient. Read the recomputed intersection instead of evaluating loss at the previous flow.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.
Problem sheet 5 · Surface forces and system curves
Determine loads from a pressure or wake survey and find the operating point after a network change.
Move the point of application
A rectangular 0.40 m chord, 1.0 m span panel has pressure-coefficient difference falling linearly from 1.4 at the leading edge to zero at the trailing edge. The dynamic pressure is 300 Pa. Estimate lift, centre of pressure and moment magnitude about the quarter-chord position.
Reveal the worked solution
The average coefficient difference is 0.70, so
The triangular load acts one third of the chord from the larger end, at 0.1333 m. The quarter-chord is 0.100 m from the leading edge, giving moment magnitude \(84(0.0333)=2.80\,\mathrm{N\,m}\). This is a leading-order thin-panel calculation.
Integrate a two-zone survey
Behind a long cylinder in air at density 1.25 kg/m³, a far-wake survey finds velocity 7 m/s in a central strip 20 mm wide and 9 m/s in two neighbouring strips each 15 mm wide. The undisturbed speed is 10 m/s. Estimate drag per span and the drag coefficient based on diameter 25 mm.
Reveal the worked solution
The pressure-recovered momentum deficit is
The reference force per width is \(0.5(1.25)(10)^2(0.025)=1.5625\,\mathrm{N/m}\), giving \(C_D=0.552\). Counting only the central strip misses a substantial share of the deficit.
Open unequal branches
A pump delivers head \(24-0.25Q^2\) metres with Q in litres per second. Static lift is 4 m. Parallel delivery branches have losses \(1.0Q_1^2\) and \(4.0Q_2^2\) metres. Find equivalent resistance, total delivery and flow split. Verify equal branch losses.
Reveal the worked solution
The equivalent coefficient is
The head balance gives \(Q^2=20/(0.25+4/9)=28.8\), hence \(Q=5.367\,\mathrm{L/s}\). Equal branch losses imply \(Q_1=2Q_2\), giving 3.578 and 1.789 L/s. Either branch loses 12.8 m, so the pump supplies 16.8 m including static lift.
Infer an equivalent roughness from two pressure taps
A level, constant-bore pipe has \(D=60.0\,\mathrm{mm}\). At mean speed \(2.00\,\mathrm{m\,s^{-1}}\), a 60.0 m fully developed length loses 5.00 m of water head. Take \(\nu=1.00\times10^{-6}\,\mathrm{m^2\,s^{-1}}\). Determine the Darcy factor and infer the equivalent roughness. Explain how an unnoticed valve loss between the taps would affect the inferred number.
Show the worked solution
Exponentiate the Colebrook relation to obtain
With the measured factor this gives
The hidden valve would raise the measured loss at this flow, raising both the assigned pipe factor and its inferred roughness. The result would then describe the installation at one operating point.
Revisit chapter 10 · Calculate a pipe resistance from roughness and flow rate.
Measure viscosity with a falling calibration bead
A spherical bead of radius 0.300 mm and density \(1500\,\mathrm{kg\,m^{-3}}\) falls 12.0 mm in 20.0 s after its speed settles. The liquid density is \(1000\,\mathrm{kg\,m^{-3}}\). Walls are distant. Infer dynamic viscosity, check the creeping-flow criterion, and estimate how a 2% overestimate in radius affects the reported viscosity if speed is measured independently.
Show the worked solution
The measured terminal speed is
Solving the buoyancy–drag balance gives
From the inferred viscosity \(Re_d=1000(0.000600)(0.000600)/0.1635=0.00220\), consistent with the assumed limit. Since \(\mu\propto a^2\), the inferred viscosity is higher by \(1.02^2-1=4.04\%\). Timing more precisely does not correct a radius calibration error.
Revisit chapter 9 · Settling in the creeping-flow limit.
Explore the governing equations after solving the sheet: Pressure integration, lift and drag; Pump curves, pipe networks and operating points. Compare the assumptions and units before transferring your chosen parameters; the controls may cover a different numerical range from the written exercise.
Chapter 11 · Angular momentum and work in a rotor
Use absolute and blade-relative velocities to derive the ideal head developed by a rotating impeller.
From first principles
Obtain rotor work from angular momentum and shaft power
A rotating impeller transmits work by changing the angular momentum carried by fluid. Choose a control volume around the rotor, with axisymmetric inlet and outlet sections. Let \(V_\theta\) be absolute tangential velocity, \(r\) the representative radius, \(\dot m\) steady mass flow and \(\Omega\) rotor angular speed. With negligible torque on other boundaries, the torque exerted by the blades on the fluid is outgoing minus incoming angular momentum flux.
Mechanical power from a rotating shaft is torque times angular speed. Divide by mass flow and write \(U_j=\Omega r_j\) for local blade speed. This gives Euler's turbomachinery work and its corresponding ideal head.
A velocity triangle relates the absolute velocity to the moving blade through \(\mathbf V=\mathbf U+\mathbf W\), where \(\mathbf W\) is relative velocity. A positive \(w_E\) adds energy to the fluid. Measured hydraulic head can be smaller owing to losses, even when the angular-momentum accounting itself is exact.
Derivation and applications
Extract reaction torque from stationary guide vanes
A stator can carry torque while delivering no shaft power. Consider a steady incompressible annular flow passing through stationary guide vanes. Assume the inlet and outlet flow each have a representative radius, reasonably uniform tangential speed and negligible externally applied torques other than the vanes. Axisymmetric pressure on inlet and outlet planes contributes no torque about the axis. For mass flow \(\dot m\) the instantaneous angular momentum per unit mass is \(rV_\theta\), so its outgoing minus incoming flux fixes the torque applied to the fluid.
The torque on the casing and the work on the stream are different measurements. A row rotating at angular velocity \(\Omega\) performs shaft work per unit mass proportional to the change in angular momentum. The stationary row follows by setting \(\Omega=0\) even when the change in swirl is substantial.
For a stator at constant height with equal axial velocities at inlet and outlet, reduction of swirl releases kinetic energy. In an ideal lossless row with zero shaft work, Bernoulli's balance transforms that kinetic energy into static pressure.
Viscous dissipation lowers the actual recovered pressure. It does not alter the angular-momentum balance when fluxes and all external torques are measured correctly. Residual outlet swirl therefore affects both casing torque and the pressure available downstream.
Worked example
Predict the reaction of a water straightener
Water flows at 2.00 kg/s through vanes at representative radius 0.100 m. Its tangential speed decreases from 4.00 to 1.00 m/s in the same direction. The fluid pushes the casing with \(2.00(0.100)(4.00-1.00)=0.600\) N m. At \(\rho=1000\) kg/m³ the maximum ideal pressure gain is
The stationary casing absorbs the moment while transmitting zero mechanical power.
Change the inputs and inspect this calculation below
Second application
Recover an exit angle from casing torque
A second stator takes in air with \(V_{\theta1}=12.0\) m/s at \(r_1=0.150\) m. A 0.900 N m positive casing torque at \(\dot m=0.750\) kg/s leaves \(r_2 V_{\theta2}=1.80-0.900/0.750=0.600\) m²/s. With \(r_2=0.120\) m, outlet swirl is 5.00 m/s. At axial speed 20.0 m/s, the absolute flow direction is \(\arctan(5/20)=14.0^\circ\) from the axis.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Convert a change of swirl into shaft torque
A fluid element can gain energy in a rotating impeller even if its inlet and outlet are at the same elevation. The rotor exerts a torque that changes the angular momentum carried by the flow. Draw a fixed control volume around the rotor. In a steady, single-inlet, single-outlet approximation, with representative mass-flow-weighted tangential velocities \(V_{\theta1},V_{\theta2}\), the axial torque on the fluid is \(\dot m(r_2V_{\theta2}-r_1V_{\theta1})\). Positive tangential velocity points in the direction of shaft rotation.
Multiplying by shaft angular speed converts torque to power. Divide by the mass flow to obtain the Euler specific work. Writing blade speeds \(U_i=\omega r_i\) avoids confusion between the angular velocity of the hardware and the velocity components of the fluid.
A pump adding energy has positive \(w_E\) under this convention. A turbine removes energy from the fluid and develops shaft output corresponding to a decrease in the fluid’s angular momentum. A stationary guide vane may change swirl while doing no shaft work because its angular speed is zero.
Relate the blade angle to the exit flow
At each station absolute velocity is the vector sum of local blade velocity \(U\) and velocity \(W\) relative to the moving blade. The throughflow component of \(V\) equals that of \(W\) when the blade motion is purely tangential. For an ideal radial impeller with backward-curved blades, define outlet angle \(\beta_2\) from the backward tangent towards the radial throughflow. Then \(W_{\theta2}=-V_{r2}\cot\beta_2\) and \(V_{\theta2}=U_2-V_{r2}\cot\beta_2\). State this angle convention before reading a drawing; other conventions change the algebraic appearance.
Predict work and distinguish hydraulic delivery
Let the outer radius be 0.10 m, rotor speed 1800 rpm, outlet radial velocity 3.0 m/s, exit blade angle 30°, and inlet swirl zero. The tip speed is 18.85 m/s; the ideal absolute exit swirl is
Hence specific work is 257.4 J/kg and head \(257.4/9.81=26.24\,\mathrm m\). For water at 8.0 L/s the mass flow is about 8.0 kg/s. Rotor torque on the fluid is \(8(0.10)(13.65)=10.92\,\mathrm{N\,m}\), and work rate is 2.06 kW.
If measurements show an actual delivered head of 21 m at this flow, hydraulic output is \(8(9.81)(21)=1.65\,\mathrm{kW}\). The ratio of actual head to the ideal blade-following estimate is 0.800. It combines departures from the ideal exit triangle with hydraulic losses in this simplified comparison. Mechanical bearing loss would additionally enter a comparison with measured shaft input power. If inlet guide vanes add positive inlet swirl, the subtracted \(U_1V_{\theta1}\) term reduces specific work for the same exit conditions.
Connect the triangle to pump affinity
For geometrically similar operation at unchanged impeller diameter, a fixed ratio \(V_r/U\) holds the ideal outlet triangle shape constant. Flow then scales with shaft speed, head with speed squared and hydraulic power with speed cubed. A real installation with static lift need not move between similar operating points when speed changes.
Derive work from a jet in a moving bucket
A radial pump uses an impeller to add angular momentum to a confined flow. An impulse turbine reverses the sequence: a stationary nozzle first converts pressure head to a high-speed free jet, which transfers momentum to buckets at nearly ambient pressure. Let jet speed \(V_j\) be tangential at the runner and bucket speed \(U\) positive in that direction. Relative inlet speed is \(V_j-U\). Suppose the bucket turns this relative stream through angle \(\pi-\beta\) and its exit relative speed magnitude is \(k(V_j-U)\), with \(k\le1\) accounting for relative-flow loss. The exit tangential absolute speed is
A succession of buckets intercepts the full continuous nozzle mass flow \(\dot m=\rho Q\), unlike one isolated vane travelling away from a jet. Neglect leakage, windage and mechanical losses. Tangential runner force is \(\dot m(V_j-V_{\theta2})\), hence shaft work per kilogram and hydraulic efficiency relative to incoming jet kinetic energy are
Differentiating with respect to speed at fixed inlet jet and exit geometry gives \(U=V_j/2\) for maximum power. At zero bucket speed force can be large but shaft power is zero. At bucket speed equal to jet speed there is no relative inlet stream to turn and therefore no useful momentum transfer. These two limits expose an incorrectly drawn exit velocity triangle.
Compare torque at the design and off-design speeds
A laboratory nozzle delivers 12 L/s of water at 30 m/s to a runner of pitch radius 0.20 m. Adopt \(k=0.85\) and \(\beta=15^\circ\), so
At optimum speed \(U=15\,\mathrm{m/s}\) and \(\omega=75\,\mathrm{rad/s}\), about 716 rpm. The runner force is \(12(30-15)(1.821)=328\,\mathrm N\), torque 65.6 N m, and power \(15(328)=4.92\,\mathrm{kW}\). The jet supplied \(12(30^2)/2=5.40\,\mathrm{kW}\), giving efficiency 91.0% under these idealised runner assumptions.
Load the shaft until bucket speed drops to 9 m/s. The force rises to \(12(21)(1.821)=459\,\mathrm N\) and torque rises to 91.8 N m, but power drops to \(9(459)=4.13\,\mathrm{kW}\). Increased measured torque therefore does not demonstrate improved conversion without the speed measurement. The exit tangential velocity becomes \(9-0.85(21)\cos15^\circ=-8.24\,\mathrm{m/s}\), indicating the bucket now reverses some absolute tangential momentum. Maintaining the assumed jet flow requires sufficient nozzle head independently of shaft loading; a restricted supply may change both jet velocity and flow rate during the test.
At ideal design speed the leaving water still has a radial or transverse velocity because \(\beta\) is nonzero. Its relative exit transverse component is \(k(V_j-U)\sin\beta=3.30\,\mathrm{m/s}\). The absolute tangential component is \(15-0.85(15)\cos15^\circ=2.69\,\mathrm{m/s}\), giving residual jet kinetic energy about 9.1 J/kg. The rest of the gap between inlet kinetic energy and shaft work includes dissipation associated with \(k<1\). It would be incorrect to attribute the entire efficiency shortfall to measured tangential exit velocity alone. Traversing velocity components or collecting the discharge separately provides a diagnostic of losses within the bucket.
Chapter 12 · Compressible nozzles and choking
Relate area change to Mach number and calculate the limiting mass flow through a converging nozzle.
From first principles
Derive the area–velocity relation for an isentropic stream
Consider a steady, quasi-one-dimensional flow through a smooth duct of area \(A\). Assume negligible viscosity, heat exchange and elevation change, and no shocks. Density \(\rho\) and speed \(V\) vary between stations. Mass conservation gives constant \(\rho VA\), so taking logarithmic differentials relates three fractional changes.
Streamwise momentum gives
For an isentropic change, sound speed satisfies \(a^2=(\partial p/\partial\rho)_s\) so the pressure differential can be eliminated in favour of density. With \(M=V/a\) this yields
Subsonic flow accelerates in a contraction because its density variation is comparatively small. A supersonic stream accelerates in a diverging duct because density falls more rapidly. A smooth transition through \(M=1\) with nonzero velocity gradient requires a stationary area, usually the minimum area of a nozzle. Reservoir state and downstream pressure determine whether that sonic condition is actually reached.
Derivation and applications
Recover subsonic Mach number from stagnation pressure
A forward-facing pressure probe brings a small sample of moving gas nearly to rest. Relating the resulting pressure to speed requires accounting for compressibility. Consider a calorically perfect ideal gas, constant heat-capacity ratio \(\gamma>1\), no heat input or shaft work, and subsonic flow brought reversibly to rest. Neglect the height change. Use \(a^2=\gamma R T\), Mach number \(M=V/a\) and \(c_p=\gamma R/(\gamma-1)\). The steady energy balance gives
For an isentropic ideal gas, \(p/\rho^\gamma\) is constant. Using the gas law to eliminate density yields a pressure ratio as a power of the temperature ratio. This provides a relation between a stagnation tap and a separate static tap at the same upstream state.
Solve for the nonnegative speed magnitude. A static temperature measurement is needed to convert dimensionless Mach number into dimensional velocity. Expanding the pressure law for small Mach number recovers the familiar dynamic pressure as its leading term.
Both pressures in the ratio must be absolute. A supersonic probe can form a shock and its recovered stagnation pressure then differs from the reversible upstream value.
Worked example
Estimate air speed from two pressure readings
For air take \(\gamma=1.40\), \(R=287\) J/(kg K), \(T=290\) K, \(p=90.0\) kPa and \(p_0=106\) kPa. Their ratio is 1.178, giving \(M=\sqrt{5[(106/90)^{2/7}-1]}=0.489\). The sound speed is 341 m/s, so the flow speed is about 167 m/s. The incompressible pressure estimate using static density would be higher because the gas compresses while it decelerates.
Change the inputs and inspect this calculation below
Second application
Predict the pressure ratio of a calibration stream
A second air stream has measured speed 102 m/s and static temperature 288 K, yielding \(a=340\) m/s and \(M=0.300\). At static pressure 100 kPa, the stagnation rise is
The leading incompressible expression predicts
Their 0.14 kPa difference sets a scale for the pressure resolution needed to detect compressibility here.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Incorporate expansion work and mass conservation
Gas accelerates through a nozzle by converting enthalpy into kinetic energy. At sufficiently high speeds, density changes appreciably and a constant-density volume balance fails. For steady one-dimensional adiabatic flow without shaft work or appreciable elevation change, \(h+V^2/2=h_0\). A calorically perfect gas has \(h=c_pT\); its local sound speed is \(a=\sqrt{\gamma RT}\), and Mach number is \(M=V/a\). Evaluate \(a\) at local static temperature, rather than at the upstream reservoir temperature.
Assume the acceleration is reversible, so \(dp=a^2d\rho\) along the isentrope. Differential momentum balance gives \(dp=-\rho VdV\), hence \(d\rho/\rho=-M^2dV/V\). Inserting this in continuity \(d\rho/\rho+dV/V+dA/A=0\) gives the area–velocity relation
A subsonic stream accelerates through a converging passage. A supersonic stream accelerates through a diverging one. A smooth transition through sonic conditions requires a stationary area, conventionally a minimum-area throat for acceleration from subsonic to supersonic speed. A converging nozzle supplied from rest can first reach Mach one at its smallest area, the exit.
Obtain the throat state from the reservoir
In the upstream reservoir the flow is essentially at rest, so its static pressure and temperature are stagnation values \(p_0,T_0\). Combining \(c_p(T_0-T)=V^2/2\) with \(c_p=\gamma R/(\gamma-1)\) gives
Apply the ideal-gas isentropic pressure–temperature relation to find the critical pressure and temperature ratios at \(M=1\).
With exit area fixed, lowering back pressure increases mass flow until the exit becomes sonic. Further reduction in back pressure does not change the ideal throat state for fixed reservoir conditions. Expansion downstream can then adjust the emerging jet to its surroundings.
Estimate a choked discharge
An insulated converging air nozzle has throat area \(50\,\mathrm{mm^2}\) and reservoir conditions 300 kPa absolute and 300 K. Use \(R=287\,\mathrm{J/(kg\,K)}\) and \(\gamma=1.40\). The critical temperature is \(300(2/2.4)=250\,\mathrm K\), critical pressure \(300(2/2.4)^{3.5}=158.5\,\mathrm{kPa}\), density \(158500/(287\times250)=2.21\,\mathrm{kg/m^3}\) and critical speed \(\sqrt{1.4(287)(250)}=317\,\mathrm{m/s}\).
Atmospheric back pressure of 100 kPa lies below the critical pressure, so the ideal mass flow is
A back pressure of 210 kPa would leave this converging nozzle unchoked, and the exit state must then be calculated from that back pressure. Real contraction and boundary-layer losses can reduce the flow through a calibrated orifice compared with the ideal nozzle prediction; a measured discharge coefficient accounts for those effects within its tested range.
Predict changes at a choked throat
At fixed reservoir pressure, the critical temperature is proportional to \(T_0\), critical density to \(1/T_0\) and critical speed to \(\sqrt{T_0}\). Their product shows that the choked mass flow scales as \(p_0A^*/\sqrt{T_0}\) for the same gas. Warming the original reservoir from 300 to 360 K at unchanged absolute pressure therefore reduces the ideal mass flow by \(\sqrt{300/360}=0.913\), to about 0.0320 kg/s. Increasing throat area or reservoir pressure has a direct linear effect while the downstream pressure stays low enough to maintain choking.
Derive the admissible jump from conservation laws
Supersonic gas in a duct can decelerate abruptly through a normal shock. The shock is thin compared with the duct dimensions, so treat it as a stationary discontinuity of unchanged area. Take a calorically perfect gas, no heat or shaft work and negligible elevation change. Mass, streamwise momentum and stagnation enthalpy are conserved:
Entropy increases through the shock, so the two end states cannot be joined with the isentropic pressure–temperature relation. Set \(r=\rho_2/\rho_1=V_1/V_2\). Momentum gives \(p_2/p_1=1+\gamma M_1^2(1-1/r)\) and the gas law gives
Substitution into the energy equation yields two roots, one for unchanged flow and the compression solution
For \(M_1>1\) this second state has higher density and lower Mach number. As \(M_1\to1^+\), every state ratio tends to unity. For very large upstream Mach number the compression ratio approaches \((\gamma+1)/(\gamma-1)\) in the constant-specific-heat approximation, although real-gas changes eventually limit that approximation.
Calculate a diffuser’s stagnation-pressure loss
Air upstream of a normal shock has \(M_1=2.0,\ p_1=80\,\mathrm{kPa}\) absolute and \(T_1=250\,\mathrm K\). Use \(\gamma=1.4,\ R=287\,\mathrm{J/(kg\,K)}\). The density ratio is
Hence \(p_2=360\,\mathrm{kPa}\) and \(T_2=250(4.50/2.667)=421.9\,\mathrm K\). The downstream Mach number is
Upstream speed is approximately 634 m/s and mass conservation gives about 238 m/s downstream.
The stagnation temperature upstream is \(250[1+0.2(4)]=450\,\mathrm K\); downstream it is \(421.9[1+0.2(0.577)^2]=450\,\mathrm K\) as required by energy conservation. Evaluate stagnation pressure separately from each local state by a hypothetical isentropic deceleration on its own side. Upstream \(p_{01}=80(1.8)^{3.5}=626\,\mathrm{kPa}\), whereas downstream \(p_{02}=360(1.0667)^{3.5}=451\,\mathrm{kPa}\). Recovery \(p_{02}/p_{01}=0.721\) shows that a large static pressure rise can accompany a 28% loss of stagnation pressure. For the same stagnation temperature the entropy rise is \(-R\ln(0.721)=94\,\mathrm{J/(kg\,K)}\), a positive value consistent with the irreversible deceleration.
A pitot tube facing the upstream supersonic flow forms its own shock ahead of the tip. The final stagnation pressure measured there corresponds ideally to isentropic deceleration after the probe’s shock, about 451 kPa here, rather than to the upstream isentropic stagnation pressure of 626 kPa. A conventional subsonic pitot reduction applied to the reading would therefore infer an incorrect upstream speed. By contrast, a static pressure tap placed sufficiently far upstream can still report the 80 kPa static state. The ratio \(451/80=5.64\) illustrates why the probe configuration must be stated when comparing a pressure ratio with a compressible-flow prediction.
The downstream temperature calculation can also be checked using mass flux. The upstream density is \(80000/[287(250)]=1.12\,\mathrm{kg/m^3}\) and the measured downstream static values imply \(360000/[287(421.9)]=2.97\,\mathrm{kg/m^3}\). Multiplication by the corresponding velocities gives roughly \(707\,\mathrm{kg/(m^2s)}\) on both sides. A calculation conserving stagnation pressure instead would generally fail one of these basic balances even if its pressure trend looked plausible.
The shock also changes the area needed to choke a downstream passage. For a given gas the choked mass flow scales as \(A^*p_0/\sqrt{T_0}\). Stagnation temperature is unchanged but stagnation pressure drops to 72.1% of its upstream value. Passing the same mass flow therefore requires a downstream critical area larger by \(1/0.721=1.39\). This does not mean the physical duct jumps in area at the normal shock. The critical area is the sonic reference area for an isentropic stream tube drawn from each side, and the two hypothetical reference conditions differ because entropy has increased.
A converging test section downstream that was sized from the upstream stagnation pressure may consequently choke earlier than expected. The entropy and critical-area tests point to the same lost capacity from different directions: one uses the gas state, the other its maximum deliverable mass flux. Together with conservation of actual mass flux at the shock, they make it possible to distinguish a real shock loss from a simple mismatch between static and total pressure instrumentation.
Find the two states that share a nozzle area ratio
For steady isentropic flow of a calorically perfect gas, combine continuity with stagnation enthalpy and the isentropic pressure law. The critical area \(A^*\) is the area giving Mach one for the same mass flow and stagnation state.

Read values from the plot
| Mach number | Heat-capacity ratio 1.3 | Heat-capacity ratio 1.4 | Heat-capacity ratio 1.667 |
|---|---|---|---|
| 0.15 | 3.9522 | 3.9103 | 3.8063 |
| 0.8125 | 1.0344 | 1.0333 | 1.0305 |
| 1.475 | 1.1714 | 1.1597 | 1.135 |
| 2.1375 | 2.0248 | 1.8977 | 1.6749 |
| 2.8 | 4.1165 | 3.5001 | 2.6222 |
Interactive calculation · change the inputs of this example
Change heat-capacity ratio and target area. Track both Mach branches and their common sonic limit.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.
Problem sheet 6 · Rotor work and compressible discharge
Close angular momentum and nozzle balances while distinguishing measured performance from ideal reference states.
Add inlet pre-swirl
An impeller has \(U_1=9,\ U_2=18\) m/s, exit swirl 12 m/s and positive inlet swirl 3 m/s. Fluid mass flow is 4 kg/s. Find Euler work, power transfer and head. What changes if inlet swirl is reversed at unchanged exit conditions?
Reveal the worked solution
Specific work is \(18(12)-9(3)=189\,\mathrm{J/kg}\); ideal power transfer is 756 W and head 19.27 m. With reversed inlet swirl the term becomes positive in the work difference, giving 243 J/kg, 972 W and 24.77 m. The change reflects a larger increase in the angular momentum of the fluid.
Reconstruct the velocity triangle
At an ideal radial impeller exit the blade speed is 24 m/s, radial fluid velocity 4 m/s and backward blade angle 45°. Calculate exit swirl, absolute speed magnitude and work at zero inlet swirl. If delivered head is 40 m, find the ratio of measured to ideal head.
Reveal the worked solution
The blade-relative tangential component is \(-4\cot45^\circ=-4\,\mathrm{m/s}\), giving \(V_{\theta2}=20\,\mathrm{m/s}\). The absolute speed is
Work is \(24(20)=480\,\mathrm{J/kg}\), or 48.93 m ideal head. The measured head ratio is
Compare two back pressures
Air at 400 kPa absolute and 360 K discharges through an ideal converging nozzle of exit area 30 mm². Use \(\gamma=1.4\), \(R=287\,\mathrm{J/(kg\,K)}\). Are back pressures 180 and 250 kPa choked? Find mass flow in the choked case and exit speed in the unchoked case.
Reveal the worked solution
Critical pressure is \(400(2/2.4)^{3.5}=211.3\,\mathrm{kPa}\); 180 kPa chokes, 250 kPa does not. At choking \(T^*=300\,\mathrm K\), \(\rho^*=2.45\,\mathrm{kg/m^3}\), \(a^*=347.2\,\mathrm{m/s}\), hence \(\dot m=0.0256\,\mathrm{kg/s}\). At 250 kPa,
The energy balance with \(c_p=1004.5\,\mathrm{J/(kg\,K)}\) gives
Find the operating point and account for the lost head
A pump between two open tanks supplies head Hₚ = 24 − 0.020q² metres, where q is measured in litres per second. The upper surface is 4.0 m higher, and pipe losses give hL = 0.030q² metres. With water density 1000 kg/m³ and pump efficiency 0.75, find volume flow, electrical input assuming an ideal motor, and the share used to raise the water. Then throttle the discharge by adding 0.030q² of valve loss.
Worked solution
Equalising pump and system head gives 0.050q² = 20, or q = 20.0 L/s. The head is 16.0 m, split into 4.0 m elevation and 12.0 m pipe loss. The fluid receives ρgQH = 3.14 kW and the assumed motor supplies 4.19 kW. Only 0.785 kW raises gravitational potential. It is one quarter of the fluid power and about 18.8% of the input.
With the valve, 0.080q² = 20 gives 15.81 L/s and a pump head of 19.0 m. Pipe and valve each dissipate 7.50 m. The new fluid power is 2.95 kW and useful lift power is 0.620 kW. Increasing the system resistance reduces flow even as the operating head rises.
An energy check sums elevation, pipe and valve contributions at the new flow. Extrapolating a fixed 75% efficiency beyond this example would need a measured efficiency curve. Also, tank surface velocities are negligible here; a discharge jet carrying appreciable kinetic energy would add an endpoint term.
Explore the governing equations after solving the sheet: Angular momentum and work in a rotor; Compressible nozzles and choking. Compare the assumptions and units before transferring your chosen parameters; the controls may cover a different numerical range from the written exercise.
Chapter 13 · How a moving wall sends momentum into a liquid
A plate oscillating horizontally in a deep bath has no average velocity. It nevertheless dissipates energy continuously. A velocity measurement at two heights can reveal the fluid’s viscosity.
Keep the unsteady term in a parallel flow
Let \(y\) increase upward from a very broad, horizontal plate. The liquid is Newtonian and incompressible with constant kinematic viscosity \(\nu\); the plate moves parallel to itself with speed \(U\cos\omega t\). Ignore edges, any pressure gradient along the plate and transients left from starting the motion. By symmetry the velocity has a single component \(u(y,t)\). A parcel has no vertical speed and meets no streamwise velocity variation, so convective acceleration vanishes even though the motion is time dependent. Horizontal momentum balance on a slice of thickness \(dy\) compares its acceleration with the shear-stress difference on its two faces.
Velocity is prescribed at the plate by no slip and tends to zero far away. The same equation describes thermal diffusion with temperature in place of velocity. Here the quantity transferred is horizontal momentum, and a velocity gradient sets its transfer rate.
Read decay and phase from one complex root
Represent periodic velocity by the real part of \(\widehat u(y)e^{i\omega t}\). Inserting it into the equation gives
Since \((1+i)^2=2i\), the decaying branch of the solution has an exponent with equal real and imaginary parts.
Every increase in height by \(\delta\) divides the amplitude by \(e\) and delays the phase by one radian. This \(\delta\) is a scale rather than a physical edge. The unbounded solution requires the top and sidewalls to be far enough away for the amplitude there to be negligible. At five penetration depths it is less than one percent of its value at the plate.
Worked example · interpret a submerged velocity probe
In an oil with \(\nu=5.0\times10^{-5}\) m²/s, set \(f=2.00\) Hz and \(U=0.080\) m/s. Using \(\omega=2\pi f\) gives \(\delta=2.82\) mm. At 3.00 mm the predicted amplitude is
The phase lag is 1.06 rad or 0.0846 s. A synchronized velocity snapshot can therefore show nearly stationary liquid while the wall speed is large. A single instantaneous ratio generally differs from the ratio of fitted amplitudes.
Worked example · power delivered to the wall layer
The wall exerts on the fluid a tangential traction \(-\mu u_y(0,t)\). Its complex amplitude is \(\mu U(1+i)/\delta\). Only the in-phase part contributes to power averaged over a cycle, since averaging a product of two cosines gives one half of the cosine of their phase difference. Thus
For the same oil at density 900 kg/m³, \(\mu=0.045\) Pa s and the mean power is 0.0510 W/m². The positive value is consistent with viscous dissipation even though mean shear and mean speed separately vanish.
Freeze the phase at a quarter cycle and find the depth at which the velocity first changes sign away from the wall. Sweep the phase to distinguish that moving zero from the stationary amplitude envelope, then double the frequency and predict the new penetration depth.
A related OneSimulation calculation
The course flat-plate calculation provides a second momentum-diffusion example. Predict what doubling viscosity does to the measured layer thickness at a fixed downstream station, then compare the square-root scaling across the two geometries.
Tutorial · estimate a material property without a force sensor
At 1.00 Hz two probes spaced 2.00 mm vertically report fitted amplitudes in the ratio upper/lower = 0.500. Estimate \(\delta,\nu\), and the phase difference. Identify a measurement that would falsify this model even if the amplitude ratio agreed.
Use both the magnitude and phase predictions
The spacing divided by \(\delta\) is \(\ln2\), giving \(\delta=2.89\) mm. Then \(\nu=\omega\delta^2/2=2.62\times10^{-5}\) m²/s. The upper signal must lag by 0.693 rad, equivalent to 0.110 s. A substantial phase discrepancy suggests confinement, an unremoved transient or motion beyond a one-dimensional shear layer. Fitting both observables is a stronger test than assigning a viscosity to every amplitude pair.
Further reading · MIT 2.25, Stokes’ second problem (PDF)
Chapter 14 · A cylinder in potential flow and the absent drag
A pressure field can vary by several dynamic-pressure heads around a body while producing exactly zero resultant drag in an ideal flow. Derive the field and identify what a real measurement must add.
Satisfy two boundary conditions with a potential
Consider steady two-dimensional flow of constant density far from a circular cylinder of radius \(a\). Assume irrotational motion in the exterior, an inviscid fluid and zero circulation. Then \(\mathbf u=\nabla\phi\) and incompressibility gives
The incoming uniform velocity \(U\mathbf e_x\) has potential \(Ur\cos\theta\). The cylinder cannot absorb fluid, so the radial velocity must vanish at \(r=a\). Seek a correction with the same angular dependence and write \(\phi=f(r)\cos\theta\). The polar Laplacian reduces to
The coefficient of the growing term must be \(U\) for the far field. The derivative \(f'=U-B/r^2\) vanishes at \(a\) if \(B=Ua^2\). Taking radial and tangential derivatives then gives the complete external velocity field.
The surface speed is zero at the upstream and downstream points. At either side it reaches \(2U\). The tangency condition constrains the normal component alone. At a real viscous wall liquid immediately adjacent to the solid also satisfies zero tangential speed. The ideal surface speed should be interpreted as an outer-flow prediction.
From speed to pressure and from pressure to force
Along streamlines Bernoulli relates static pressure to speed at the same height. Since the incoming flow is uniform and irrotational the same Bernoulli constant applies throughout this ideal solution. Normalize the pressure change by \(q=\rho U^2/2\). On the body,
Pressure force on an arc per unit span is \(-p(\cos\theta,\sin\theta)a\,d\theta\). Points at \(\theta\) and \(\pi-\theta\) have identical pressures and opposite horizontal normals. The corresponding drag contributions cancel exactly. Top and bottom symmetry cancels lift. A real cylinder can have a separated wake with low rear pressure. Substituting the attached-flow pressure at the rear is the assumption that then fails.
Worked example · read three ports
Water of density 1000 kg/m³ flows at 0.80 m/s, so \(q=320\) Pa. At the upstream stagnation point the model predicts \(p-p_\infty=+320\) Pa. At a point where the normal is 45° to the stream axis, \(\sin^2\theta=1/2\), so \(C_p=-1\) and the reading is −320 Pa. On the side the predicted reading is −960 Pa. The front-to-side difference is 1280 Pa, four times the incident dynamic pressure. A pressure transducer connected to these two ports requires the correct geometric factor before being interpreted as a speed meter.
Worked example · convert a wake discrepancy into a drag
Approximate a measured departure from the ideal pressure by reducing pressure uniformly by 150 Pa on the downstream semicircle and leaving the upstream half unchanged. For a radius of 50 mm, the added downstream force per span is
A span of 0.40 m gives 6.00 N before end effects. This integration illustrates why even a modest rear pressure error changes the net drag materially. Local low pressure on the sides contributes little horizontal force where the outward normals point almost vertically.
Begin with zero rear pressure deficit and check the pressure symmetry about the transverse axis. Introduce a 160 Pa downstream deficit at 0.80 m/s. Predict the pressure-drag coefficient from the projected area before reading the result.
Tutorial · estimate speed and test the symmetry hypothesis
An ideal front-to-side differential is 720 Pa in water. Infer the incoming speed. Two further ports mounted at 60° and 120° report a difference of 90 Pa. Can a different incoming speed make that second difference consistent with the assumed model?
Separate calibration from model failure
The front-to-side difference is \(4q=2\rho U^2\), giving \(U=0.600\) m/s. Both other ports have the same \(\sin^2\theta=3/4\). Their ideal pressure difference vanishes at every speed. A discrepancy at these ports therefore tests symmetry and the assumed attached field independently of the first calibration.
Further reading · MIT 2.25, Potential Flow Theory
Chapter 15 · Curvature pressure, wetting and capillary rise
The water height in a narrow glass tube is a measurement of an interface force. Starting from a surface energy explains both its direction and its dependence on tube radius.
Convert a surface-energy change into a pressure difference
A clean liquid–gas interface of fixed composition and temperature requires reversible work \(\gamma\,dA\) to increase its area by \(dA\). The surface tension \(\gamma\) therefore has equivalent units J/m² and N/m. Imagine a spherical drop changing radius by \(dR\). Pressure inside does work while the outside pressure resists. Equating net pressure work to the increase in interface energy gives
For a local patch with two principal radii the same argument gives \(\Delta p=\gamma(1/R_1+1/R_2)\) with signed curvature and consistently chosen normal. A cylinder has only one nonzero curvature, so the spherical factor of two is inappropriate there. A thin soap bubble has two nearly equal interfaces and doubles the pressure jump for a given radius.
Background · Capillary pressure
Principal curvatures carry signs set by the chosen normal. A cylindrical interface contributes only one finite principal curvature.
Close the balance at the wall
Put a vertical tube of inner radius \(r\) into a bath and let \(\theta\) be the contact angle measured through the liquid. Surface tension along the circular contact line has upward component \(2\pi r\gamma\cos\theta\). The excess column over the external free surface has effective weight \((\rho_l-\rho_g)g\pi r^2 h\). Neglect meniscus volume relative to the column and assume equilibrium, a broad bath, a uniform tube and a well-defined contact angle.
The sign of \(h\) changes when \(\theta\) exceeds 90°. A smaller tube gives more contact-line length per unit cross-sectional area and therefore supports a taller column. The same equation follows from the pressure jump for a nearly spherical cap of radius \(r/\cos\theta\) in magnitude and a hydrostatic pressure change. If gravity distorts the local cap considerably, the full interface shape must be solved. The capillary length \(\sqrt{\gamma/(\Delta\rho g)}\) indicates when tube radius is small on the relevant scale.
Worked example · inspect a level reading
Take water with \(\gamma=0.072\) N/m, density difference 1000 kg/m³, radius 0.400 mm and contact angle 30°. The rise is
The hydrostatic pressure difference is 312 Pa. The capillary length is about 2.71 mm, comfortably larger than the radius. A reader who assumes perfect wetting would infer 36.7 mm. The uncertainty in surface condition can therefore exceed a millimetre-scale ruler uncertainty.
Worked example · use a second liquid column as a test
In a tube of radius 0.500 mm a liquid of density 850 kg/m³ rises 10.0 mm. The product determined by this experiment is
If an independent measurement gives \(\gamma=0.0300\) N/m, then \(\cos\theta=0.695\), or \(\theta=46.0^\circ\). A second tube of half the radius should approximately double the height on identically prepared walls. It does not by itself separate contact angle from surface tension because the same product appears in both balances.
At a fixed radius rotate the contact angle through 90 degrees. Estimate the sign and magnitude just on either side of the crossing. Compare the effect of halving surface tension with doubling radius in the complete-wetting comparison.
Tutorial · compare a drop and a bubble
A clean water drop of radius 0.60 mm has \(\gamma=0.072\) N/m. Find its excess pressure. A spherical soap film of the same radius has tension 0.030 N/m at each of its two interfaces. Which object has the larger excess pressure? State a radius at which the soap bubble would match the drop.
Count each interface
The drop has one interface and excess pressure \(2(0.072)/0.00060=240\) Pa. The bubble has two interfaces and \(4(0.030)/0.00060=200\) Pa. To match 240 Pa its radius must be 0.500 mm. The liquid volume between the bubble interfaces is treated as small enough for both interface radii to coincide.
Further reading · J. Bush, MIT 18.357, Lecture 5, stress boundary conditions and the static meniscus (PDF)
Study the full derivation
Gravity, capillarity and instability at a moving interface · Momentum, motion and transport in fluids
A flat interface can carry waves restored by gravity and surface tension. If its two liquids or gases move at different speeds, a band of those waves can grow. Derive the ideal threshold, identify the most vulnerable wavelength at onset and distinguish growth of an instability from advection of an otherwise stable disturbance.
Chapter 16 · Critical depth and the hydraulic jump
In a wide shallow channel the same discharge can pass as a shallow fast stream or as a deeper slow stream. A gradual hump and an abrupt jump connect depths through different conservation laws.
Minimise the energy needed to carry a discharge
Use a broad rectangular channel and let \(q=Q/b\) be its volume flow per unit width. At a section with approximately uniform speed \(u\) and water depth \(h\), mass conservation gives \(u=q/h\). Take pressure to be hydrostatic over the depth and neglect losses between adjacent smooth sections. Measured relative to the local channel bottom, specific energy in metres of head is
The derivative vanishes at \(h_c=(q^2/g)^{1/3}\), where \(\mathrm{Fr}=u/\sqrt{gh}=1\). The second derivative \(3q^2/(gh^4)\) is positive. Critical depth is the unique minimum, with \(E_c=3h_c/2\). The speed \(\sqrt{gh}\) is the speed of small long gravity waves relative to shallow water. When \(u\) exceeds it, even a disturbance travelling upstream relative to the liquid is carried downstream relative to the bed.
Background · Froude number
For shallow rectangular flow with gravity waves this compares material speed to wave speed. Critical depth occurs when the two are equal.
Worked example · decide if a smooth rise can pass the flow
A channel carries \(q=0.40\) m²/s at depth 0.50 m. Speed is 0.80 m/s and specific energy is
Critical depth is 0.2536 m and the minimum specific energy is 0.3804 m. Since total head includes bed elevation, a local rise of up to about 0.152 m can be accommodated in the ideal fixed-upstream-state model. A higher rise requires the upstream water level or discharge to adjust. For a small rise on the subcritical branch the available specific energy decreases and depth decreases toward the critical value.
Keep momentum across a short rapid transition
A hydraulic jump is turbulent and strongly dissipative. Place control surfaces far enough upstream and downstream for pressure to be hydrostatic again. Across a short horizontal reach, neglect net bed shear compared with the momentum and end-pressure forces. The hydrostatic force on an end section is \(\rho g h^2/2\) per unit width, obtained by integrating a triangular pressure profile. Momentum flux is \(\rho q^2/h\). Requiring equal momentum functions gives
Factor out \(h_2-h_1\) and take the distinct-depth root. With \(r=h_2/h_1\), the remaining relation is
The positive solution and associated energy drop are
The loss is positive for a jump from shallow to deep flow. Reversing the depths would require a gain in mechanical energy without a source, which excludes that continuation of the same algebraic equation.
Worked example · locate the conjugate depth
At a flume section let \(h_1=0.100\) m and \(u_1=2.00\) m/s. Then \(q=0.200\) m²/s and \(\mathrm{Fr}_1=2.02\). The depth ratio is 2.40, giving \(h_2\simeq0.240\) m and \(u_2\simeq0.835\) m/s. Upstream energy is 0.304 m and downstream energy about 0.275 m. Momentum balance predicts a head drop near 0.0285 m. Its location along the channel also depends on the imposed tailwater level; the two-section balance itself contains no position variable.
Follow the head over the bump until its horizontal line just touches the energy curve. Estimate the maximum admissible bed rise from the two vertical readings. Predict how changing discharge moves that tangency before changing the input.
Tutorial · infer discharge from two depth gauges
Two gauges straddle a stationary jump and report 0.12 and 0.30 m. Use the momentum relation to recover the discharge per unit width, determine which side is upstream and calculate the specific mechanical-energy loss.
Recover the flow and check its direction
Factoring the momentum equality gives \(q^2=g h_1 h_2(h_1+h_2)/2\), hence \(q=0.2724\) m²/s. The shallow side has speed 2.27 m/s and Froude number 2.09. The deeper side has speed 0.908 m/s and Froude number 0.529. Taking the shallow side upstream yields energy loss \(0.18^3/[4(0.12)(0.30)]=0.0405\) m. Both discharge and the sign of dissipation support this ordering.
Further reading · W. Smyth, All Things Flow, §9.3, hydraulic jumps and bores
Chapter 17 · A viscous squeeze film as a rate-dependent support
Bring two smooth circular disks slowly together with a thin layer of liquid between them. The force needed depends strongly on gap size even when neither surface is elastic.
Decide which motion the gap permits
Take rigid parallel disks of radius \(R\) separated by \(h(t)\ll R\), filled with an incompressible Newtonian liquid of viscosity \(\mu\). The lower disk is fixed and the upper disk approaches at speed \(V=-\dot h>0\). Assume an axisymmetric film discharging to ambient pressure at the edge, no slip on both disks and negligible inertia. The latter requires viscous stress to dominate transient and convective inertia, including the scale \(\rho Vh/\mu\ll1\). Fluid displaced from the centre must travel sideways through the thin film. Across-gap derivatives dominate radial derivatives of velocity, and the leading pressure is uniform through the thickness.
Two integrations give
The pressure gradient must be negative for outward flow. Integrating velocity over the gap gives radial volume flow per circumferential length \(q_r=-h^3(dp/dr)/(12\mu)\). The cubic power comes from a velocity scale proportional to \(h^2\) multiplied by the available gap \(h\).
Balance the displaced volume inside every circle
The film inside radius \(r\) loses volume at rate \(\pi r^2 V\). With no compressibility or leakage through the disks this must equal \(2\pi r q_r\). Hence \(q_r=rV/2\). Match to the viscous flow relation, integrate inward from \(p(R)=p_a\), and sum the excess pressure over the wetted disk:
The pressure distribution is parabolic; its area average is half its centre value. A fixed-speed actuator sees a rapidly increasing load as the film narrows. Conversely a constant load makes the approach slower. An experiment must state which of speed or force is controlled before two records can be compared.
Worked example · halve a film thickness
Let \(R=20\) mm, \(h=0.20\) mm, \(\mu=0.10\) Pa s and \(V=0.10\) mm/s. The centre excess is
The net force is 0.942 N. Reducing the gap to 0.10 mm at unchanged speed raises pressure and force by eight, giving 12.0 kPa and 7.54 N. Reducing speed by eight at the thinner gap would recover the original force. The model consequently distinguishes a viscous support from a spring by repeating the same gap at different rates.
Worked example · integrate the approach at constant load
Rearrange the force law to \(-dh/dt=2Fh^3/(3\pi\mu R^4)\). Separation of variables gives
Under a constant 1.00 N load the example disk takes 2.83 s to go from 0.20 to 0.10 mm. The ideal time to reach zero mathematical thickness diverges. Real surfaces eventually develop solid contact at roughness peaks, and departures from parallel alignment can redirect much of the pressure distribution.
First halve the gap and then independently halve the approach speed. Predict how the centre pressure changes in each trial. Check the area-average line against the radial curve and explain why an unweighted average over radius gives a different value.
Tutorial · identify a viscosity and test the boundary assumption
At gap 0.15 mm, disks of radius 15 mm give 2.00 N at 0.25 mm/s. Infer the viscosity. Predict the load if a vented outer annulus reduces the effective wetted radius to 12 mm while the gap and velocity stay fixed.
Integrate over the wetted radius
The inverse is \(\mu=2Fh^3/(3\pi V R^4)=0.113\) Pa s. With the edge now open to ambient at 12 mm, force scales by \((12/15)^4=0.4096\), giving 0.819 N. Simply multiplying the original force by the area ratio would miss the change in peak pressure caused by the shorter flow path.
Further reading · MIT 2.25, §6.4, locally developed viscous flows and lubrication
Chapter 18 · How turbulent momentum transport produces a logarithmic velocity profile
The time-averaged velocity next to a wall looks smooth, even when individual velocity records fluctuate rapidly. Decompose the momentum flux, derive the wall scaling, and recover a shear stress from two measurements in the logarithmic region.
Where the turbulent shear stress comes from
For an incompressible constant-density fluid write \(u=U+u'\) and \(v=V+v'\), with uppercase velocities time averages and mean fluctuations zero. The flux of streamwise momentum carried in the wall-normal direction contains \(\rho\,\overline{uv}=\rho(UV+\overline{u'v'})\). In a statistically steady parallel mean flow with \(V=0\), the apparent shear transporting streamwise momentum toward the wall becomes
Upward moving near-wall fluid often carries lower-than-average streamwise momentum and descending fluid carries higher-than-average momentum. Both events have negative \(u'v'\) in this sign convention, producing a positive turbulent shear. At a stationary impermeable no-slip wall fluctuations vanish and the entire wall stress is viscous, even when turbulence dominates a short distance away.
Match the inner scales and a constant-stress layer
Define \(u_\tau=\sqrt{\tau_w/\rho}\), \(y^+=yu_\tau/\nu\) and \(U^+=U/u_\tau\). Close enough to the wall \(dU/dy\simeq\tau_w/\mu\), so \(U^+\simeq y^+\). Farther out, provided y is still small compared with the outer flow thickness, take \(\tau_{\rm total}\simeq\tau_w\) and viscous stress small. Prandtl's mixing-length closure approximates the turbulent shear by \(\rho \ell_m^2|U'|U'\). The near-wall dimensional assumption \(\ell_m=\kappa y\) gives
The constant B must come from matching or measurements. Use illustrative smooth-wall values \(\kappa=0.41,\ B=5.0\). The line \(U^+=y^+\) applies in the viscous sublayer and the log line only in an overlap region (often beyond about \(y^+=30\) and well inside the outer layer). In between lies a buffer region. Extending a logarithm to the wall would violate the no-slip condition. Roughness and adverse pressure gradients alter these comparisons.
Predict a difference, then use it as a stress measurement
Take water with \(\rho=1000\) kg/m³, \(\nu=10^{-6}\) m²/s and \(u_\tau=0.040\) m/s. Wall stress is 1.60 Pa. At \(y=0.05\) mm, \(y^+=2\), so the viscous prediction is \(U=0.080\) m/s. At 1.0 mm and 4.0 mm, \(y^+=40,160\). If both points are in the overlap region, their velocity difference is \((0.040/0.41)\ln4=0.1353\) m/s; B cancels. The individual predicted speeds are about 0.560 and 0.695 m/s. A log-linear plot over many positions is a stronger test than fitting a line to just two values.
Suppose two probes 0.80 and 3.20 mm from a similar wall instead read a difference of 0.100 m/s. The inferred friction velocity is \(0.41(0.100)/\ln4=0.0296\) m/s and the inferred stress is 0.875 Pa. The lower probe then has \(y^+=23.7\), which makes the logarithmic assumption questionable there. This check feeds the inferred parameter back into the condition for the inference. Repositioning both probes at larger wall distances, while staying away from the outer flow, supplies an independent test.
Increase viscosity while holding friction velocity fixed. Predict how the two displayed validity intervals move in millimetres. Use the reported wall distances in viscous units to decide whether a logarithmic fit through fixed probes is still plausible.
A related OneSimulation calculation
Use the laminar flat-plate calculation to compare two definitions of wall shear. Infer the wall gradient from viscosity and shear, then consider which additional velocity covariance enters an averaged turbulent momentum balance.
Tutorial · compare pressure-drop and velocity-gradient estimates
A fully developed round pipe of radius 25 mm has \(-dp/dx=160\) Pa/m. Derive its wall shear by balancing axial pressure force and perimeter friction. Predict the increase between two overlap-layer points whose distances have a ratio of three.
Derive the wall force and velocity increment
For pipe length L the pressure force is \((-dp/dx)L\pi R^2\), balanced by \(\tau_w2\pi RL\), hence
In water \(u_\tau=0.0447\) m/s. The expected speed increase is
The pressure-force result remains an exact mean balance under the fully developed assumptions. The profile comparison additionally depends on the closure and the placement of both probes.
Further reading · ETH Zürich · turbulence lecture, law of the wall and logarithmic layer
Study the full derivation
Estimate wall drag by integrating a boundary-layer profile · Momentum, motion and transport in fluids
A velocity probe can resolve the momentum missing from a boundary layer more easily than the wall shear itself. Derive an integral momentum relation, estimate drag using a polynomial profile and determine when a pressure gradient or a measurement too far from the wall changes the answer.
Chapter 19 · How gravity and surface tension select different wave speeds
A long crest and a millimetre-scale ripple on the same deep liquid can travel at different speeds. Derive their dispersion relation from two surface boundary conditions and distinguish the motion of a crest from the motion of a narrow packet.
Continue the surface motion down into the liquid
Use z positive upward, liquid occupying \(z<0\), and an undisturbed planar free surface at zero. Neglect viscosity and consider small-amplitude irrotational motion. The velocity is \(\nabla\phi\); incompressibility requires
A horizontal Fourier component \(e^{i(kx-\omega t)}\) with \(k>0\) therefore has vertical dependence \(e^{kz}\) in water deep compared with \(1/k\). The other Laplace solution grows without bound as \(z\to-\infty\) and is discarded. Let \(\eta\) denote surface elevation. Linearising the kinematic condition at z=0 gives \(\eta_t=\phi_z\), since the surface moves with the normal fluid velocity.
Translate curvature and elevation into surface pressure
For small slope the liquid surface pressure above atmospheric is \(-\gamma\eta_{xx}\), positive beneath a crest. Linear Bernoulli with the hydrostatic shift at the rising surface gives \(\phi_t+g\eta-(\gamma/\rho)\eta_{xx}=0\) at z=0. For amplitudes \(\Phi,\hat\eta\), the kinematic condition gives
Insert this in the dynamic condition to eliminate \(\Phi\):
For long deep-water gravity waves \(c_g\simeq c_p/2\). In the opposite capillary limit \(c_g\simeq3c_p/2\). Thus tracking the envelope of a short group and timing an individual crest can give different speeds even with accurate instruments. Finite depth would multiply the right-hand side for \(\omega^2\) by \(\tanh(kH)\); deep-water long-wave asymptotics still require \(kH\gg1\).
Find the slowest crests and time a wave packet
For water take \(\rho=1000\) kg/m³ and \(\gamma=0.072\) N/m. Differentiating \(c_p^2\) with respect to k gives a stationary point at \(k_*=\sqrt{\rho g/\gamma}\), so
Here gravity and capillarity contribute equally to \(\omega^2\); the minimum phase speed is 0.231 m/s. Also \(d(kc_p)/dk=c_p+k\,dc_p/dk=c_p\) at this point. Thus group and phase velocities coincide locally.
At 100 mm wavelength the predicted phase and group speeds are 0.401 and 0.212 m/s. At 10 mm they are 0.247 and 0.307 m/s. Over a 0.50 m path a narrow 10 mm packet envelope takes about 1.63 s, whereas timing a crest across the same distance would give 2.03 s if it stayed observable. Surface contamination changes effective restoring and damping behaviour, and dispersion broadens a packet with appreciable bandwidth.
Find where phase and group speed meet, then halve the surface tension and predict the new wavelength of that crossing. Time an individual short crest and its packet over half a metre. Which arrives first on either side of the crossing?
Tutorial · recover surface tension from a measured frequency
A sinusoidal mode of wavelength 12.0 mm oscillates at 20.0 Hz in deep water of density 1000 kg/m³. Infer its surface tension using the full relation and estimate the error caused by discarding gravity. Which depth would make the deep-water approximation credible?
Solve for the constitutive parameter
With \(k=523.6\) m⁻¹ and \(\omega=125.66\) rad/s, \(\gamma=\rho(\omega^2-gk)/k^3\simeq0.0742\) N/m. Omitting gravity gives about 0.110 N/m, roughly 48% high. At depth 10 mm, \(kH=5.24\) and \(\tanh(kH)\) exceeds 0.9999, making the finite-depth correction very small in this model. Frequency, wavelength and depth should all be measured before attributing a discrepancy to surface chemistry.
Further reading · John Bush, MIT · lecture 8 on water waves, curvature and dispersion
Study the full derivation
Gravity, capillarity and instability at a moving interface · Momentum, motion and transport in fluids
A flat interface can carry waves restored by gravity and surface tension. If its two liquids or gases move at different speeds, a band of those waves can grow. Derive the ideal threshold, identify the most vulnerable wavelength at onset and distinguish growth of an instability from advection of an otherwise stable disturbance.
Chapter 20 · Watch a wetting front approach the capillary height
Dip two clean glass tubes of different inner radii into the same wetting liquid. A microscope following only the first few millimetres of rise can give a different impression of which tube fills more readily than a photograph taken at equilibrium. Start with the force on one meniscus, derive a transient relation including gravity, and learn which measurements can distinguish a change of viscosity from a change of surface condition.
Balance the surface force against a pressure difference
Let \(a\) be the tube radius and \(\theta\) the advancing contact angle measured through the liquid. The vertical component of surface tension along a circular contact line is \(2\pi a\sigma\cos\theta\). Dividing by the cross-sectional area equates this force to a capillary pressure magnitude \(p_c=2\sigma\cos\theta/a\). The liquid pressure immediately below a wetting meniscus is below the gas pressure. An equivalent derivation uses a spherical cap and the Young–Laplace pressure jump with radius of curvature \(a/\cos\theta\). Both derivations require a meniscus whose transverse shape is set mainly by capillarity, so \(a\) should be small compared with the capillary length \(\sqrt{\sigma/(\rho g)}\).
Take \(z\) to be the height of the meniscus above an effectively infinite open reservoir. The bottom and the gas above the meniscus share the same external atmospheric pressure. A static column can sustain the hydrostatic head \(\rho g z\). Equating that head with \(p_c\) gives the equilibrium height \(H=2\sigma\cos\theta/(\rho g a)\). A wider tube has a smaller equilibrium rise. Viscosity does not enter this statement: after flow stops, there is no viscous pressure drop.
This equilibrium construction implicitly neglects the small volume in the curved meniscus, any entrance flow below the reservoir surface, and changes in the contact angle as the wall wets. These corrections matter when the rise is only a few tube radii. They can also matter in comparing two nominally identical capillaries cleaned in different ways. A practical measurement should define whether the microscope tracks the meniscus centre, a contact line or an optical threshold. An inconsistent definition looks like an offset in the inferred height.
Relate the instantaneous capillary force to wall shear
Farther inside a long circular tube the local pressure gradient sets a parabolic velocity profile for steady, fully developed laminar flow. Applying this relation quasi-steadily to a column of length \(z\), the pressure loss is \(8\mu z\,\bar u/a^2\). Conservation of liquid volume in a tube of uniform cross-section identifies \(\bar u=\dot z\). The pressure remaining to drive viscous motion is the capillary jump less the hydrostatic head. Therefore
The driving pressure falls as the column grows, and its hydraulic resistance grows at the same time. These two effects account for the long final approach to equilibrium. Introduce \(B=\rho g a^2/(8\mu)\), which has dimensions of velocity. The resulting first-order equation is
Close to the entrance it predicts an arbitrarily large speed when \(z\) tends to zero. The approximation has discarded fluid inertia, entrance losses and moving contact-line dynamics. Treat the early viscous law as an intermediate asymptotic once a wetted column exists. A good fit late in the record is no evidence for that divergent initial prediction.
To integrate the differential equation it is simplest to regard time as a function of height. Set \(s=z/H\) and \(\tau=H/B\). Then \(dt/\tau=s\,ds/(1-s)\). Integrate from zero to \(s\), choosing the nominal clock origin at vanishing length. The result is
The right side is increasing. The notebook uses bisection to invert it for height at a specified laboratory time. The two bracket endpoints have clear physical meanings, zero rise and the equilibrium rise. Near \(s=0\), direct subtraction of \(s\) from \(-\ln(1-s)\) can discard significant digits. Evaluating the logarithm with log1p and using the power series for very small \(s\) preserve the small positive elapsed time.
Read two distinct time laws from one expression
Expanding the logarithm gives
To leading order \(z^2=2HBt=a\sigma\cos\theta\,t/(2\mu)\). At a common early time, a wider tube therefore has a larger height proportional to \(\sqrt a\). It has less capillary pressure but its resistance per unit length falls rapidly with radius. An experiment that accelerates the initial uptake by increasing radius can simultaneously reduce the final available lifting height.
Near equilibrium write \(s=1-\epsilon\). The implicit solution reads \(t/\tau=-1+\epsilon-\ln\epsilon\). To leading order \(\epsilon\simeq\exp[-1-t/\tau]\). The final height is approached exponentially and is never reached in finite time by this idealisation. Fitting a straight line in \(z^2\) against \(t\) across this late part of the record will overestimate the viscosity if gravity is omitted, because it attributes the slower rise entirely to viscous resistance. A semilog plot of \(H-z\) is a more appropriate late-time diagnostic, although uncertainty in \(H\) becomes more important as the difference shrinks.

Interactive calculation · Capillary rise
Change the physical and numerical inputs of the notebook model. Compare the updated curves and balance checks with the recorded notebook figures. Each plot uses the same equations and assumptions documented in that notebook; its readout names any analytical or reduced-model reference.
For \(a=100\) µm, \(\mu=0.012\) Pa s, \(\rho=1000\) kg/m³, \(\sigma=0.060\) N/m and \(\theta=30^\circ\), the predicted static height is 105.94 mm. The time scale is about 103.7 s. Reaching 25%, 50% and 90% of that height takes approximately 3.91, 20.02 and 145.40 s. The time to half height is not half the time to a specified near-equilibrium height. At half height the exact dimensionless time is
The leading square-root estimate gives only 0.125 and underestimates the time by about 35% relative to the exact result.
Use a static observation and a moving observation together
In a high-viscosity sample a single short-time image constrains only the combination \(\sigma\cos\theta/\mu\) if all you have is the early growth rate. A change of surface chemistry and a change of viscosity can produce the same slope. A static-height measurement independently fixes \(\sigma\cos\theta\) for a known radius, density and gravity. Combining it with the time to half height gives a viscosity estimate \(\mu=\rho ga^2t_{1/2}/[8H(\ln 2-1/2)]\). The two measurements have different parameter dependences, which is what makes the inverse calculation possible.
Consider the limitations of this estimate. A slowly falling reservoir shifts the elevation origin and changes the effective head. Evaporation from the front can drive a persistent flow even with an apparently stationary meniscus. A wall with contact-angle hysteresis can hold a range of static heights. Repeating the experiment after prewetting the tube changes which contact angle is relevant. Observing both the growing profile and the final plateau helps locate these effects. Reducing the residual of a single two-parameter fit can otherwise conceal them.
Estimate viscosity using only passage times at two marks
A camera need not capture the instant of immersion if the tube carries two calibrated height marks. Select marks at \(z_1=0.25H\) and \(z_2=0.50H\) using an independent long-time reading of \(H\). If the camera clock has an unknown constant offset, subtract the recorded times. The offset cancels exactly. With \(F(s)=-s-\ln(1-s)\) the model gives
The bracket is about 0.15547. A measured interval of 16.11 s therefore gives \(\tau=103.6\) s. Substituting this value into \(\mu=\rho g a^2\tau/(8H)\) gives approximately 0.0120 Pa s for the stated dimensions. The two-mark construction does not cancel a time-varying camera rate or an error in the static height.
Where should the marks be placed? Two marks very close together make the absolute timing uncertainty large relative to the measured interval. Setting the second mark extremely near equilibrium can also be troublesome because a small height uncertainty then produces a large uncertainty in passage time. Differentiate the dimensionless time to obtain
At half height its slope is one, while at ninety percent it is nine. The same one-percent error in fractional height produces approximately nine times as much time uncertainty at the latter mark as at half height. Use the movie to estimate a passage-time uncertainty from the meniscus location itself, alongside the uncertainty of one video frame.
The notebook also feeds three specified camera times into OneSimulation’s vectorised bracketed inverse in a local installation. After identifying the corresponding heights, substitute them back into the time law. This checks the inversion independently of a visual match between two trajectories.
Exercises on scaling and interpretation
1. Enlarge the tube radius by 50% while holding all material parameters fixed. Predict the ratios of final height, initial square-root coefficient and time to half of the new height.
Work through the solution
The static height is inversely proportional to radius, so the height ratio is \(2/3\). The coefficient in \(z=C\sqrt t\) scales as \(\sqrt a\), giving \(C_{\mathrm{new}}/C_{\mathrm{old}}=\sqrt{1.5}=1.225\). The time scale behaves as \(\tau\propto a^{-3}\). Reaching half of the smaller final height now takes about \(20.02/(1.5)^3=5.93\) s. The two experiments reach different absolute heights at their respective half-height times.
2. In a tube of known radius the static rise is unchanged after a fluid is replaced, but the time to 50% height doubles. What quantity changes in this model?
Work through the solution
At fixed density, gravity and radius the observed \(H\) fixes \(\sigma\cos\theta\). The dimensionless time at 50% is fixed, so a doubling of \(t_{1/2}\) doubles \(\tau\) and hence doubles the viscosity. If density also changes, the measurements constrain the kinematic combination \(\mu/\rho\) and the capillary combination \(\sigma\cos\theta/\rho\), so an independent density measurement is needed to identify dynamic viscosity.
3. A plot of \(z^2\) versus time is linear over the first recorded interval. Does that identify the contact angle uniquely?
Work through the solution
Its slope is \(a\sigma\cos\theta/(2\mu)\) in the gravity-free viscous regime. Knowing only the radius leaves several unknown factors. Independent measurements of viscosity and surface tension would give \(\cos\theta\). Even then, a dynamic advancing angle could differ from the static angle, so compare with the plateau and inspect whether the inferred angle varies with the chosen fit interval.
Read the original capillary-flow argument
Washburn’s paper The Dynamics of Capillary Flow develops the connection between viscous motion and capillary pressure. In comparing radii, first decide whether the experimental observable is a penetration length, a transported volume or a fraction of equilibrium height.
Interactive calculation · when gravity invalidates the early rise law
Select a target height and compare the exact implicit rise time with the early square-root approximation. The radius and viscosity affect dimensional times even though the dimensionless correction collapses onto one universal curve.
Problem sheet 7 · A capillary that fills horizontally and climbs vertically
A transparent tube draws a wetting liquid from a large reservoir. Combine a static meniscus balance with a viscous pressure-drop law to predict a transient, recover a property from timing and determine where the simplest startup model fails.
1 · Predict the final height before timing the rise
The inner radius is 0.200 mm, surface tension 0.072 N/m, contact angle 30°, density 1000 kg/m³ and dynamic viscosity 0.010 Pa s. Neglect gas viscosity and assume the radius is small relative to the capillary length. Calculate the pressure head supplied by the meniscus and the final vertical rise.
Calculate pressure and static elevation
A spherical-cap meniscus gives
Hydrostatic pressure balances it at \(H=\Delta p/(\rho g)=63.6\) mm. Viscosity does not enter this equilibrium balance. A liquid with the same density and surface properties but twice the viscosity therefore arrives at the same final level under these assumptions.
2 · Turn a pressure drop into a filling-time law
First lay the tube horizontally. Denote the filled length by x. In developed laminar flow the mean speed is \(r^2\Delta p/(8\mu x)\). With constant tube area, the speed of the meniscus is that mean speed. Predict the time to fill 50 mm and the effect of doubling viscosity.
Integrate the resistance that grows with the filled length
Equating \(\dot x\) to the mean liquid speed gives
Integrating from negligible initial length gives
The time for 50 mm is
Doubling viscosity doubles the filling time. At x=25 mm the prediction gives about 0.0125 m/s, with Reynolds number based on diameter about 0.50. Laminar resistance is then plausible. Extrapolating its infinite startup speed to zero length would neglect entrance inertia and the formation of the velocity profile.
3 · Predict a measurable fraction of the vertical rise
Turn the tube upright. Only \(\Delta p-\rho g x\) remains available for viscous losses. Derive a time formula for \(0<x<H\). Find the time to H/2 and compare with the time needed to reach that same length horizontally.
Solve the separable moving-front equation
Write \(K=\rho gr^2/(8\mu)=0.004905\) m/s, which gives
Integration of \(dt=x\,dx/[K(H-x)]\) yields
At half height this becomes
Horizontal filling over the same 31.8 mm takes 1.62 s. The logarithm diverges as \(x\to H\), so a laboratory definition such as “within 1 mm of the final level” is necessary when reporting an arrival time.
4 · Recover viscosity independently of contact angle
Suppose a fresh tube of the same radius gives static rise 60.0 mm and fills 40.0 mm horizontally in 3.00 s. Infer the viscosity without fitting a contact angle. Which pair of measurements lets you test whether static and dynamic wetting agree?
Eliminate the unknown capillary pressure
The vertical rise yields
Horizontal integration gives \(\mu=r^2\Delta p\,t/(4x^2)=0.0110\) Pa s. Compare this inferred value with independent viscometry and record the meniscus angle during travel. A moving contact angle different from the static value changes the pressure available during the horizontal run. A time trace at several lengths also tests the assumed \(x^2\propto t\) scaling.
Problem sheet 8 · Calibrate a rotational viscometer without a thin-gap assumption
An inner cylinder rotates inside a stationary cylindrical cup filled with a Newtonian liquid. Instruments often convert torque to viscosity with a gap approximation. Solve the actual cylindrical velocity field, use the measured torque to infer viscosity and determine how end drag or secondary flow would appear in a calibration series.
Find the velocity field from stress balance
Take inner radius \(a=15\) mm, outer radius \(b=20\) mm and active length \(L=80\) mm. The inner cylinder rotates at \(\Omega=5.0\) rad/s; the outer one is fixed. Assume steady axisymmetric flow with no radial or axial velocity, no slip and negligible end effects. Why is the shear rate not simply the derivative of tangential velocity? Derive the velocity between the two walls.
Compare neighbouring angular velocities
A fluid rotating as a rigid body with \(u_\theta=\Omega r\) has nonzero radial velocity gradient but zero shear deformation. The cylindrical shear rate that respects this fact is \(r\,d(u_\theta/r)/dr\). The torque transmitted through a coaxial cylinder is \(2\pi Lr^2\tau_{r\theta}\). In a steady purely azimuthal flow with no body torque this is independent of radius. For Newtonian viscosity \(\mu\), integrate \(r^3\,d(u_\theta/r)/dr=\text{constant}\) to find
Applying both wall speeds gives
It returns \(a\Omega=0.075\) m/s at the inner wall and zero at the outer wall. Mid-gap speed is approximately 0.0344 m/s rather than the 0.0375 m/s of a straight line. A small-looking velocity discrepancy can have a larger effect on stress because stress contains a derivative and a curvature correction.
Infer viscosity from the measured torque
The measured sidewall torque after bearing drag subtraction is 0.646 mN m. Determine the viscosity, the magnitude of inner wall shear stress and the result a laboratory would get using a planar gap model. Identify which direction the resulting viscosity bias takes.
Integrate shear traction with the lever arm
Differentiating the velocity solution yields
The liquid resists the inner cylinder, so the applied steady drive torque is positive and has magnitude
The measurement implies \(\mu=0.250\) Pa s. Inner stress is
A planar gap estimate uses wall speed \(a\Omega\) divided by \(b-a\) as the shear rate. It predicts 0.424 mN m at the true viscosity and would infer 0.381 Pa s from the actual reading. The sign of bias follows from the cylindrical shear being larger than the assumed planar rate at the inner surface.
Reducing gap while keeping inner radius fixed makes both approximations approach one another. The trade-off is that fractional uncertainty in the actual clearance can become large relative to machining tolerances or eccentricity. Measuring the two radii independently to good absolute precision need not yield an accurately known very small difference.
Check the power balance and use an active-length sweep
Predict the mechanical power entering the liquid. Show that it equals the viscous dissipation integrated over the annulus. How could torque at two lengths separate the intended sidewall response from an approximately length-independent end contribution?
Integrate power and isolate the intercept
Driving power is \(T\Omega=3.23\) mW. Local dissipation density is \(\mu[r\,d(u_\theta/r)/dr]^2\). Multiplying by \(2\pi rL\,dr\) leaves an integral proportional to \(\int_a^b dr/r^3\), giving exactly the drive power after substitution of both radii. This check tests both the factor of two and the sign convention in the torque derivation. It also predicts a small but continuous heat load whose importance depends on the sample's thermal control.
If lengths 40 and 80 mm yield measured torques 0.373 and 0.696 mN m, the slope is 8.08 mN m per metre and extrapolated end intercept 0.050 mN m. The inferred 80 mm sidewall contribution is 0.646 mN m as assumed. This correction relies on similar end geometry and sidewall flow at both lengths. A varying free surface, slip, secondary recirculation or contact-line torque can change that intercept with immersion.
Distinguish non-Newtonian behaviour from a failing flow geometry
The graph lets you change viscosity while monitoring the profile shape and computed torque. Explain what an observed nonlinear relationship between torque and angular speed would mean and what it would fail to identify by itself.
Test independent model assumptions
In the assumed Newtonian steady regime, wall speeds set the entire velocity shape independently of viscosity, while torque scales linearly with viscosity and rotation rate. At fixed geometry, a nonlinear torque curve can suggest a shear-dependent viscosity. It can also result from heating, a moving contact line, wall slip, inertia-driven secondary circulation or a changing parasitic bearing contribution. Repeat at controlled temperature and multiple active lengths, acquire upward and downward speed sweeps and measure reversibility after full equilibration.
The inner rotating configuration can develop Taylor vortices above an onset that depends on geometry and fluid properties. A torque departure accompanied by axial cellular motion violates the assumed single azimuthal component. A velocity profile measured near the cylinder centre and away from its ends supplies information unavailable in one total torque. In the benign low-speed calibration one can also use a reference liquid of known viscosity and repeat for different gaps; collapse onto the finite-gap prediction is a stronger test than fitting a single instrument factor.
MIT Continuum Electromechanics · shear flow and a Couette viscometer
Notebook practice · Watch a wetting front approach the capillary height
Momentum, motion and transport in fluids
Derive a flow from its conservation laws and boundary conditions. Quantify how length scales and material properties decide which approximation can predict a measurement.
- Gravity, capillarity and instability at a moving interface
A flat interface can carry waves restored by gravity and surface tension. If its two liquids or gases move at different speeds, a band of those waves can grow. Derive the ideal threshold, identify the most vulnerable wavelength at onset and distinguish growth of an instability from advection of an otherwise stable disturbance.
- Settling spheres, Stokes drag and a wall correction
A falling-sphere viscometer infers viscosity from terminal speed. Derive the drag on a no-slip sphere, distinguish creeping flow from merely steady motion and use radius, vessel width and orientation checks to decide what the speed experiment actually measures.
- Why shear disperses a tracer faster than molecular diffusion
A short dye pulse in a straight tube first stretches into a filament and much later resembles a broadened one-dimensional cloud. Derive the long-time Taylor–Aris coefficient, predict the width of a measured pulse and identify the mixing time needed before fitting the familiar one-dimensional approximation.
- Estimate wall drag by integrating a boundary-layer profile
A velocity probe can resolve the momentum missing from a boundary layer more easily than the wall shear itself. Derive an integral momentum relation, estimate drag using a polynomial profile and determine when a pressure gradient or a measurement too far from the wall changes the answer.
- How long does a moving wall take to set a fluid layer in motion?
Start the top of a narrow gap suddenly and follow the velocity, volume flow and wall stresses as viscous diffusion builds a Couette profile.
- How far upstream does a downstream water level matter?
A depth gauge downstream of a change in bed level measures a local state. Predict the depth one kilometre upstream by combining energy, cross-section geometry and a resistance law, then fit the roughness against independent uniform-flow readings.
- How can a constant-area duct choke?
A nozzle reaches a sonic state by changing area. A straight pipe can approach the same Mach number through friction or through heating. The two cases conserve different combinations of stagnation properties.
Momentum, motion and transport in fluids · 1. Gravity, capillarity and instability at a moving interface
A flat interface can carry waves restored by gravity and surface tension. If its two liquids or gases move at different speeds, a band of those waves can grow. Derive the ideal threshold, identify the most vulnerable wavelength at onset and distinguish growth of an instability from advection of an otherwise stable disturbance.
Impose kinematic conditions on both fluids
Consider two immiscible inviscid incompressible fluids of effectively infinite depth. The lower fluid has density \(\rho_1>\rho_2\); base velocities \(U_1,U_2\) are uniform and parallel to a horizontal interface at \(z=0\). Let its small displacement be \(\eta e^{i(kx-\omega t)}\) with \(k>0\). Assume irrotational disturbances within each layer, so their potentials satisfy Laplace's equation. Decay away from the interface gives forms \(A_1e^{kz}\) below and \(A_2e^{-kz}\) above. An interfacial vortex sheet is still allowed because tangential base velocities differ.
A material point on either side stays on the perturbed interface in the normal direction. Applying \((\partial_t+U_j\partial_x)\eta=\partial_z\phi_j\) gives
Pressure perturbations from linear Bernoulli include both the unsteady potential and hydrostatic change at the displaced surface. Equating pressure jump to the surface-tension curvature force yields
Gravity restores long waves for the stated stable density ordering, while surface tension restores short waves. Check the equal-velocity limit: adding the same velocity to both layers merely Doppler-shifts the wave frequency and cannot make a stable interface unstable.
Complete the square and locate the first unstable wavelength
Define density-weighted velocity \(\bar U=(\rho_1U_1+\rho_2U_2)/(\rho_1+\rho_2)\). The squared frequency relative to \(k\bar U\) becomes the restoring right-hand side divided by total density minus \(\rho_1\rho_2 k^2(U_1-U_2)^2/(\rho_1+\rho_2)^2\). A negative value gives one exponentially growing and one decaying branch. In that regime the real frequency still advects with \(k\bar U\), while growth rate is the square root of the negative discriminant's magnitude. A moving pattern alone is insufficient evidence of instability.
For each \(k\), the squared critical relative speed is proportional to \((\rho_1-\rho_2)g/k+\sigma k\). Differentiating gives the minimum at \(k_*=\sqrt{(\rho_1-\rho_2)g/\sigma}\). For densities 1000 and 1.2 kg/m³ and tension 0.072 N/m the onset wavelength is 17.0 mm, with ideal threshold 6.66 m/s. At 7.0 m/s the growth rate at this same wavelength is about 27.6 per second, an e-fold interval of 36 ms. The wavelength giving maximum growth above threshold can differ from the onset wavelength.
Make a quantitative observation under controlled assumptions
A suitable numerical experiment starts from the same small disturbance amplitude for a set of Fourier modes and compares early exponential growth with the dispersion relation. If an initial ripple amplitude doubles from 0.10 to 0.20 mm in 25 ms, its estimated growth is \(\log2/0.025=27.7\) per second. Measure several early time windows and ensure amplitude remains small compared with wavelength. Nonlinear saturation, finite channel depth, viscosity, actual shear-layer thickness and wave generation at an inlet all change the late or measured growth. The ideal air–water threshold is not a prediction for wind-wave onset with an arbitrary atmospheric velocity profile.
Distinguish a convected disturbance from growth at one place
An unstable wave in the temporal calculation has a real wavelength and a complex frequency. Its visible crests are carried along by the density-weighted mean flow while its envelope grows. A fixed camera viewing a short section may see a larger wave on one side than on the other without observing a temporal increase at a fixed material phase. An inlet wavemaker, reflection, a varying channel depth and convective transport can each change the spatial pattern. Follow the same crest group with a time-stamped image sequence and inspect its early amplitude before the interface becomes strongly distorted.
As a simple measurement example, suppose a tracked narrow band grows from 0.20 mm to 0.40 mm in 0.10 seconds. The inferred temporal exponent is the natural logarithm of two divided by the elapsed time, or 6.93 per second. If noise adds a constant apparent amplitude floor, fitting logarithms of the earliest images can suppress the inferred slope. Measure a quiet reference sequence and repeat the estimate over several windows. Once the slope falls substantially as amplitude increases, nonlinear saturation may have begun. Extrapolating the early exponential through the late stage then overestimates growth.
At the theoretical onset the predicted growth rate vanishes. This is the least convenient location for a finite observation interval because a weakly unstable wave may scarcely grow before it leaves the field of view. Compare a sequence of speeds on both sides of threshold and plot the squared measured growth rate against squared relative velocity at one chosen wavelength. The ideal dispersion relation gives a locally linear relation and suggests a more stable intercept estimate than judging the first visibly wavy frame.
Tutorial · Recover surface tension from the onset wavelength
At the same densities, an ideal calculation with a different liquid predicts the minimum threshold at wavelength 12.0 mm. Estimate surface tension. What independent measurement checks the model without reusing the wavelength?
Invert the onset condition
With \(k_*=2\pi/0.012=524\) per metre, \(\sigma=(998.8)(9.81)/k_*^2=0.0357\) N/m. Insert that value into the threshold-speed equation and compare with a measured critical relative velocity. Wavelength alone fixes the ratio of buoyancy and tension terms in this model; matching a second independent onset observable is a stronger test. Verify that the observed wavelength corresponds to first onset rather than the fastest mode at a substantially larger speed.
Tutorial · Distinguish finite growth from a short observation
A mode has predicted growth 5.0 per second but is visible in a camera field for only 30 ms as it advects. Estimate its amplitude increase. Could an apparently constant amplitude establish stability?
Compare residence and growth times
The predicted factor is \(e^{5(0.03)}=1.162\), just sixteen percent. If amplitude noise, illumination variation or uncertainty in initial conditions is comparable, such a record cannot distinguish weak growth from neutral propagation. Measure along the convecting packet or extend the observable path, then fit log amplitude with calibrated spatial gain. A lack of measurable growth over one short camera region places only an upper bound on its rate.
Tutorial · Suppress tension in the mathematical model
Set surface tension to zero while retaining a sharp velocity discontinuity and stable gravity. What happens to the high-wavenumber threshold and why would finite-mesh simulations disagree as they are refined?
Examine the highest resolved modes
The required squared speed then falls as \(1/k\), so any nonzero velocity jump can destabilise sufficiently short waves. In the vortex-sheet idealisation their high-\(k\) growth rate scales with \(k\). Refining a numerical mesh allows faster modes previously excluded by the grid. A physically smooth shear layer, surface tension, viscosity or other physical regularisation must be specified if the small-scale evolution is important. Numerical smoothing can control a calculation but its length scale is then part of the assumed model, not a measured material parameter.
MIT Interfacial Phenomena · surface waves and Kelvin–Helmholtz instability
Momentum, motion and transport in fluids · 2. Settling spheres, Stokes drag and a wall correction
A falling-sphere viscometer infers viscosity from terminal speed. Derive the drag on a no-slip sphere, distinguish creeping flow from merely steady motion and use radius, vessel width and orientation checks to decide what the speed experiment actually measures.
Balance pressure and viscosity around a sphere
Let a rigid sphere of radius \(a\) move with small relative speed \(U\) in a Newtonian fluid. In the sphere frame impose a uniform far flow \(U\mathbf e_z\), no slip at its surface and incompressibility. If particle Reynolds number \(\rho U(2a)/\mu\) is small, drop convective inertia, obtaining \(-\nabla p+\mu\nabla^2\mathbf u=0\). Dimensional reasoning predicts a drag proportional to \(\mu aU\) but cannot determine its prefactor. That prefactor depends on the no-slip surface and three-dimensional geometry.
The axisymmetric Stokes solution has \(u_r=U\cos\theta[1-3a/(2r)+a^3/(2r^3)]\),
Substitution verifies zero surface velocity and the uniform far limit. The pressure contribution in the streamwise direction integrates as the surface integral of \(-(p-p_\infty)\cos\theta\), giving \(2\pi\mu aU\). Tangential viscous traction supplies \(4\pi\mu aU\). Their sum gives
A seemingly simpler potential-flow solution satisfying only impermeability misses the viscous traction and cannot reproduce the drag. Conversely a calculation that integrates just wall shear misses one third of this drag even at negligible inertia. The signs depend on whether one computes force of fluid on sphere or sphere on fluid; the magnitude above resists relative motion.
Balance buoyancy and find the terminal motion scale
A sphere of density \(\rho_s>\rho\) has buoyancy-corrected weight \((4\pi a^3/3)(\rho_s-\rho)g\). Equating drag and this weight yields
Take \(a=0.50\) mm, density difference 1200 kg/m³ and viscosity 0.50 Pa s. The unbounded terminal speed is 1.31 mm/s. For fluid density 1000 kg/m³, \(Re_D=0.00262\), supporting a steady creeping-flow approximation. A 30 mm timed distance then takes about 22.9 s.
A coarse transient model uses sphere inertia alone, \(m_s\dot U+6\pi\mu a U=W_{\rm eff}\), predicting relaxation time \(m_s/(6\pi\mu a)\). Actual transient hydrodynamics also contains added mass and a viscous-history contribution. Measuring a steady late portion is much safer than fitting the initial release with the simple exponential when extracting viscosity. Measure speed over successive equal intervals and check that it has become constant, away from both the release and vessel bottom.
Compare the viscous penetration time with the oscillating-wall experiment
A slow particle can still strongly interact with the container
A stationary no-slip cylindrical vessel increases drag on a sphere translating along its centreline. For small size ratio \(\lambda=a/R_{\rm tube}\), the standard leading mobility correction is \(U_{\rm tube}/U_\infty\simeq1-2.1044\lambda+\cdots\). At \(\lambda=0.05\) the measured speed is already roughly ten percent smaller. Inserting that diminished speed into an unbounded drag law biases inferred viscosity upward. A small Reynolds number does not make walls irrelevant; it only addresses inertia relative to viscosity.
Measure terminal speed from a recorded trajectory
Choose a transparent column wide enough that the sphere remains many radii from its wall in the analysed window. Convert pixel distances to physical length using a scale in the same plane as the particle centre. Refraction through a curved vessel can otherwise give different apparent distances at the wall and centre. Fit position against time over several windows beginning after release. A stable slope with changing window length supports the terminal-speed interpretation; a trend in that slope can indicate acceleration, a fluid current or proximity to the bottom.
The plot overlays the selected viscosity with a run at twice that viscosity. At fixed particle size their ideal terminal speeds differ by a factor of two. The horizontal axis invites a different comparison: the same settling speed in the more viscous fluid requires a radius larger by a factor of the square root of two. Use the numerical Reynolds number in the readout as a validity test. Increasing particle size tenfold raises terminal speed a hundredfold but diameter Reynolds number a thousandfold, so the apparent ease of tracking a larger particle has a fluid-mechanical cost.
A density inference can be especially fragile near neutral buoyancy. For example, if particle and liquid densities are 1020 and 1000 kilograms per cubic metre, an absolute uncertainty of two kilograms per cubic metre in each input is small relative to either density yet large relative to their difference. If independent it gives a standard uncertainty about 2.8 kilograms per cubic metre in the excess, or fourteen percent. Compare with the microscope radius calibration before attributing observed variation to the viscosity. Vertical temperature gradients can drive background circulation whose speed is comparable with a very slowly settling particle.
Tutorial · Estimate viscosity and its radius uncertainty
A sphere of radius 0.40 mm and density contrast 1000 kg/m³ falls at 0.80 mm/s far from walls. Infer viscosity and propagate an independent two-percent radius uncertainty, neglecting other errors.
Invert the terminal balance
The inferred viscosity is \(2(0.00040)^2(1000)(9.81)/[9(0.00080)]=0.436\) Pa s. Its radius contribution to relative uncertainty is approximately four percent because radius is squared. If density contrast is estimated by subtracting two similar measured densities, its relative uncertainty can be much larger than either density's relative error. Repeat with a sufficiently well-characterised reference sphere and measure liquid temperature since viscosity can vary markedly with it.
Tutorial · Could a speed mismatch be wall drag?
For a 0.50 mm radius sphere and a 10 mm radius tube, the measured terminal speed is 1.17 mm/s rather than the 1.31 mm/s unbounded prediction. Check the leading wall correction and propose a test that does not assume the listed viscosity is exact.
Compare a vessel-size sequence
The radius ratio is 0.050, so the leading correction predicts a factor 0.895 and speed 1.17 mm/s. Repeat in two or more wider tubes at unchanged temperature and fit speed against inverse tube radius. Extrapolation toward zero inverse radius estimates unbounded mobility without requiring the listed viscosity for the extrapolation. Off-axis migration, wall roughness, bottom confinement and finite-size higher terms must still be checked. One match to a leading coefficient does not prove perfect centring.
Tutorial · Brownian jitter or sustained background flow?
A much smaller tracer shows fluctuations in falling displacement and an unexpected common horizontal drift. How would you estimate its settling speed without attributing every displacement increment to gravity?
Separate first and second displacement moments
Brownian motion adds variance increasing with lag in a diffusive interval but no mean drift in a homogeneous quiescent bath. Background flow adds a mean vector common to passive tracers. Measure many trajectories, estimate the fluid's mean velocity with a nearly neutrally buoyant marker and subtract it before fitting mean vertical drift. Fit the residual displacement variance separately to estimate diffusion and compare with the Einstein–Stokes prediction. A static temperature gradient can generate convection or thermophoresis, so repeat at several positions or orientations before assigning a gravity-only terminal balance.
MIT Advanced Environmental Fluid Mechanics · Stokes flow past a sphere
Momentum, motion and transport in fluids · 3. Why shear disperses a tracer faster than molecular diffusion
A short dye pulse in a straight tube first stretches into a filament and much later resembles a broadened one-dimensional cloud. Derive the long-time Taylor–Aris coefficient, predict the width of a measured pulse and identify the mixing time needed before fitting the familiar one-dimensional approximation.
Cross-sectional averaging leaves a correlated flux
Consider steady fully developed laminar Poiseuille flow of mean speed \(U\) in a circular tube of radius \(a\). The axial profile is \(u(r)=2U(1-r^2/a^2)\). A dilute passive solute of molecular diffusivity \(D\) is carried by this velocity and diffuses in all directions, with no solute flux at the wall. Section-averaging its advection–diffusion equation leaves a flux \(\overline{uc}\). Splitting into mean and deviation gives \(U\bar c+\overline{u'c'}\). It is the latter covariance that disperses the pulse beyond its molecular diffusion.
At times long compared with a transverse mixing scale of order \(a^2/D\), and for a slowly varying axial average, take \(c'\simeq f(r)\partial_z\bar c\). Substituting into the leading radial balance gives
Regularity at the centre and zero wall derivative give
Integrate again and choose a constant so \(\overline f=0\). The section-integrated correlation is most easily evaluated by multiplying the radial equation by \(f\) and integrating by parts:
The negative sign means an average concentration gradient drives a net down-gradient dispersive flux. The molecular diffusivity in the denominator is not a paradox. Faster radial diffusion lets a tracer sample slow and fast streamlines more frequently and reduces long-time axial velocity memory. Taking \(D\) arbitrarily close to zero at a fixed observation time violates the long transverse-mixing requirement before the formula could diverge.
Predict a pulse width and its applicability window
For \(a=100\) micrometres, \(U=0.50\) mm/s and \(D=1.0\times10^{-9}\) square metres per second, \(Ua/D=50\) and \(D_{\rm eff}=5.31\times10^{-8}\) square metres per second. Radial mixing time \(a^2/D\) is about 10 s, corresponding to an advected length 5 mm. After 100 s, under long-tube and narrow-initial-pulse assumptions, the axial rms width is \(\sqrt{2D_{\rm eff}t}=3.26\) mm while the mean pulse has travelled 50 mm. A velocity measured from width alone is ambiguous without an independent molecular diffusivity and a check of the time regime.
A detector at a fixed axial station records concentration versus time. Converting a small spatial width to a temporal width by division by \(U\) is a local approximation when the pulse is narrow compared with distance travelled and continues broadening slowly during its passage. An absorbing detector or outlet collecting solute flux can weight the distribution differently from a nonintrusive optical section-average. State whether the instrument measures local intensity, section-average concentration or total mass flux.
Recover the parabolic base profile in the viscous-duct chapter
Background · How does a finite injection pulse change the inferred dispersion?
A tracer valve introduces a plug of finite axial width. In the long-time regime with linear transport, the measured concentration is the convolution of the released profile with the spreading kernel. After normalising both to unit mass their variances add, just as variances add for independent displacements.
A uniform 12 mm plug has initial variance \(12^2/12=12\) mm². A one-time estimate forced through zero at \(t=10\) s therefore overestimates \(D_{\rm eff}\) by 0.60 mm²/s. Two complete spatial images can eliminate the intercept if both are taken in the Taylor-dispersion regime. A camera that clips one tail does not record the full variance.
Read dispersion from the second moment of an image
After a short pulse has entered the straight observation tube, a camera integrates fluorescence across its diameter. Subtract a background frame and flat-field the illumination, integrate across the complete width, then compute the axial centroid and variance with concentration as weights. A constant gain cancels in both normalised moments. Saturating the brightest central pixels does not cancel: it reduces the measured peak more than the tails and biases the width. A window too narrow to capture the tails produces the opposite error. Shift and widen the analysis window as the pulse travels.
The figure starts several radial mixing times after injection. Its left endpoint represents an already broadened pulse; the model was derived in this late regime. For an injection with appreciable initial variance, add that variance to the predicted diffusive growth instead of forcing the variance line through zero. With a constant axial imaging blur, variances likewise add under convolution with a normalised response. In that case two late measurements can identify a slope even if the intercept includes both injection width and camera blur. Recovering the initial width from the intercept would require an independent calibration.
The radius and velocity sliders are independent. To model a pump holding flow rate fixed when the radius is doubled, divide velocity by four as well. The effective enhancement then decreases by four and the radial mixing time increases by four. Comparing observations at the same absolute time could inadvertently move one case outside the long-time regime. Compare at a stated multiple of each radial mixing time and also record the corresponding distances needed along the tube.
Tutorial · Predict what a second pulse station should see
Two nonintrusive imaging stations observe the same well-mixed pulse after mean transit times 60 and 120 seconds under the example conditions. Estimate the increase in spatial variance. Why does differencing help with uncertainty in initial injection width?
Use the long-time variance slope
The difference is \(2D_{\rm eff}(120-60)=6.37\times10^{-6}\) square metres, or 6.37 square millimetres. An initial injection variance and any common Gaussian imaging blur add approximately constant offsets to the spatial variance and cancel in this difference. If the image point spread differs between stations or the first station is still within the shear-dominated entrance transient, cancellation fails. Check more than two stations to test linear variance growth before inferring a dispersion coefficient.
Tutorial · Compare a thinner tube at fixed volumetric rate
Halve the radius while keeping volumetric flow rate and molecular diffusivity fixed, assuming fully developed laminar flow remains valid. What happens to mean velocity, transverse mixing time, dispersive enhancement and required pressure gradient?
Keep the imposed quantity fixed
Mean speed increases by four because area is quartered. Transverse mixing time falls by four. The enhancement \(U^2a^2/(48D)\) increases by four. For Poiseuille flow at fixed volume rate the required axial pressure gradient scales as \(a^{-4}\), hence increases by sixteen. At fixed mean velocity, in contrast, the enhancement would decrease by four. A claim that narrower tubes always improve or always suppress dispersion is incomplete without naming the operating constraint.
Tutorial · Interpret a non-Gaussian short-time profile
At a distance reached in only one second the optical image shows a long leading filament and a concentration tail near the wall. Does this invalidate the measured molecular diffusivity? Sketch the limiting motion if radial diffusion were absent during that interval.
Compare the observation time with the radial mixing time
One second is only a tenth of the example transverse diffusion scale. Material near the centre moves near \(2U\), while material close to a no-slip wall is almost stationary. An initially uniform cross-section pulse therefore separates by streamline velocity, covering a broad range of axial positions. A single effective Gaussian diffusion law has not yet emerged. Compare direct advection–diffusion with an independently measured initial profile, then check the long-time variance at larger distances. Wall adsorption would create additional lag even after radial mixing and can be tested by changing wall chemistry or solute type.
MIT Advanced Fluid Dynamics · section 4.7, dispersion and the Aris solution for a circular pipe
Momentum, motion and transport in fluids · 4. Estimate wall drag by integrating a boundary-layer profile
A velocity probe can resolve the momentum missing from a boundary layer more easily than the wall shear itself. Derive an integral momentum relation, estimate drag using a polynomial profile and determine when a pressure gradient or a measurement too far from the wall changes the answer.
Define displacement and momentum thickness separately
For steady incompressible two-dimensional flow over a smooth wall, let \(U_e(x)\) denote the local speed just outside a thin attached boundary layer and \(u(x,y)\) the tangential speed inside it. Displacement thickness \(\delta^*=\int_0^\infty(1-u/U_e)dy\) measures missing volume flow per unit outer speed. Momentum thickness \(\theta=\int_0^\infty (u/U_e)(1-u/U_e)dy\) measures a different deficit. Both have dimensions of length, while their ratio \(H=\delta^*/\theta\) characterises profile shape. Neither thickness is defined by a particular percentage edge speed.
Integrating the streamwise boundary-layer momentum equation and using continuity to eliminate the edge-normal flux yields
The edge pressure gradient follows outer inviscid flow through \(dp_e/dx=-\rho U_e\,dU_e/dx\). Under uniform outer speed the equation reduces to
With an adverse pressure gradient the second term is negative, and an increasingly thickening layer can still have very small or negative wall shear. Applying the uniform-speed relation outside its conditions would overestimate shear near separation.
Derive an approximate flat-plate law
Assume a laminar zero-pressure-gradient layer with \(u/U=2\eta-\eta^2\) for \(0<\eta=y/\delta<1\) and outer speed beyond. The profile satisfies no slip at the wall, reaches the edge speed and has zero first derivative at its nominal outer edge. Integrating gives \(\delta^*=\delta/3\), \(\theta=2\delta/15\), while the wall gradient gives
Substitute into the momentum integral and integrate from the leading edge:
The coefficient 0.730 from this approximate profile differs from the exact Blasius laminar result 0.664 while reproducing the square-root scaling. Profile choice closes an otherwise exact integrated balance and creates a measurable modelling error. It also treats the local leading-edge region outside its proper thin-layer asymptotics. Refining numerical integration of the same polynomial cannot eliminate the profile approximation.
For air with \(U=5.0\) m/s, \(\nu=1.5\times10^{-5}\) square metres per second, \(x=0.20\) m and \(\rho=1.2\) kg/m³, \(Re_x=6.67\times10^4\) and predicted \(\delta=4.24\) mm. The approximate local \(C_f=0.00283\) gives \(\tau_w=0.0424\) Pa. If a pressure-gradient or transition changes the profile appreciably, measure the actual shape and its \(x\) variation rather than applying this laminar estimate.
Compare the local velocity profile and wall stress with the boundary-layer chapter
Use a probe traverse to measure a momentum deficit
A small velocity probe is moved away from a smooth plate in increments of known height. Calibrate zero height and measure outer velocity independently. Convert the measured values to ratios with the outer velocity, integrate the displacement and momentum kernels using the same station coordinates, and repeat downstream. Even if the probe misses the point where the speed first reaches 99 percent of the outer value, the two integrals can remain informative. A contaminated outer-velocity estimate, however, leaves a persistent offset in the integrands across the entire outer part of the traverse.
The model overlays a profile at a selected station and at twice that station distance. In a zero-pressure-gradient laminar layer both curves collapse if wall-normal position is divided by its own thickness. The outer velocity is the same in both plots and the wall slopes differ by a factor of the square root of two. This shows why a constant free-stream speed does not imply constant wall shear. Wall shear depends on the gradient normal to the wall, and diffusion spreads the velocity change over a progressively thicker layer.
For an independent check take a measured momentum thickness of 0.55 mm at a station and 0.66 mm at a station 60 mm downstream. Their finite difference gives a slope of 0.00183 and hence a mean skin-friction coefficient of 0.00367 under uniform outer speed. A measurement error of 0.02 mm at each station, treated as independent, corresponds to roughly one quarter of the measured difference. Improving one individual profile is not enough if the station separation is too small to resolve a change. Increasing separation improves signal but averages over more streamwise development. Repeating over several separation distances exposes that tradeoff and can reveal transition within the interval.
If the same probe is used at both stations, a common calibration gain can cancel in the normalised velocity ratios. An error in the zero wall distance affects the inner region differently. Repeat the integration after deliberately shifting the nominal wall location by its measured positioning uncertainty.
Tutorial · Infer drag from two traverse stations
A constant-speed incompressible layer has momentum thickness 0.30 mm at one station and 0.50 mm 0.15 m farther downstream. With \(U=5.0\) m/s and \(\rho=1.2\), estimate mean wall shear over the interval and total drag on a strip of width 0.20 m.
Integrate the momentum relation
Mean shear is
The area is 0.030 square metres, so drag is 1.20 mN. This estimate uses the complete momentum deficit and does not require differentiating a noisy near-wall velocity. It does require both profiles to cover the entire defect region and share a calibrated outer speed.
Tutorial · Check an apparent separation claim
At one location \(H=2.5,\theta=1.0\) mm, \(U_e=4.0\) m/s, \(dU_e/dx=-8.0\) per second and \(d\theta/dx=0.010\). Infer wall shear sign. Would the same momentum-thickness growth guarantee that sign in zero pressure gradient?
Retain the pressure-gradient term
The dimensionless right side is \(0.010+4.5(0.001/4)(-8)=0.0010\), still positive but only one tenth of the zero-gradient estimate. In this example both cases have positive shear, yet a slightly stronger adverse gradient would reverse the indicated sign. Near zero the differences among several measured terms magnify relative uncertainty. A near-wall direction measurement or oil-film shear indicator can help distinguish a true sign reversal from fitted profile noise.
Tutorial · Detect a probe that misses the outer deficit
A traverse stops at the first point where measured speed reaches 97 percent of the apparent outer value. How might this bias displacement and momentum thickness, and how would you design a convergence check?
Integrate the remaining positive tail
For an attached monotone profile both integrands are positive below the true outer speed, so prematurely truncating usually underestimates both thicknesses. Near the edge their integrands become similar because \(u/U_e\simeq1\); even a small speed defect over a broad tail can contribute appreciable area. Extend the traverse and compare integrals as the cutoff rises. Independently estimate true undisturbed \(U_e\): a slight bias in that denominator can create a false nonzero tail over the entire outer integration region. Repeat at finer near-wall spacing too, separately testing quadrature and physical domain coverage.
MIT Aerodynamics of Viscous Fluids · boundary layers and momentum-integral methods
Momentum, motion and transport in fluids · 5. How long does a moving wall take to set a fluid layer in motion?
Start the top of a narrow gap suddenly and follow the velocity, volume flow and wall stresses as viscous diffusion builds a Couette profile.
Remove the final state before separating variables
Take two large, parallel plates separated by \(H\), with \(y=0\) at the fixed plate. The liquid starts from rest. At \(t=0\) the upper plate begins to move at constant speed \(U\). For an incompressible Newtonian liquid with no imposed pressure gradient, the unidirectional velocity \(u(y,t)\) has zero convective acceleration. The streamwise momentum balance on a thin slice then reduces to
With constant viscosity, kinematic viscosity \(\nu=\mu/\rho\) is the momentum diffusivity.
Use \(\eta=y/H\) and \(F=\nu t/H^2\). The linear profile \(u/U=\eta\) solves the eventual steady equation and both wall conditions. Subtract it by setting \(w=u/U-\eta\). Both boundaries now require \(w=0\), which selects eigenfunctions \(\sin(n\pi\eta)\) for \(w_F=w_{\eta\eta}\). Each amplitude decays as \(\exp(-n^2\pi^2 F)\). The interior initially has \(w=-\eta\). Multiplying by a sine and integrating from zero to one gives
Combining the parts gives
For any positive time, higher modes decay rapidly. At the initial top corner the sudden change in surface velocity conflicts with the initially resting liquid. The mathematical wall gradient there diverges as \(t\downarrow0\). A finite starting acceleration would regularize that prediction. Fluid well away from that wall sees little change until the diffusion distance, of order \(\sqrt{\nu t}\), becomes comparable with its distance to the moving surface.
Distinguish stored momentum from transmitted shear
Integrating the profile over the gap eliminates the even sine modes. The dimensionless volume flow per unit span becomes
Differentiating at the walls gives
Here both symbols report \(\mu u_y\) evaluated in the positive \(y\) direction. The forces on the fluid act in opposite directions, so the net streamwise force per unit plate area is \(\tau_\mathrm{top}-\tau_\mathrm{bottom}\).
Set \(H=4\) mm, \(\nu=1.6\times10^{-5}\) m\(^2\)/s, \(\rho=900\) kg/m\(^3\) and \(U=0.20\) m/s. The gap diffusion time is 1 s. At 0.1 s the flow is \(0.34894 UH\), already 69.8% of its final value. The wall gradients still differ sharply, measuring 1.7843 and 0.2929 times the eventual shear of 0.72 Pa. Integrating the original momentum equation over the layer verifies that their difference accelerates the stored streamwise momentum, \(\rho\,dq/dt\).
Open full-size diagram
Open full-size diagramProblem 1 · Predict the flow-settling time
Estimate when the flow reaches 99% of its final value. Why is one mode enough for this estimate?
Work through the solution
Divide the missing flow by its final value to obtain \((8/\pi^2)\sum_{n\ {\rm odd}}e^{-n^2\pi^2 F}/n^2\). Its leading term reaches 0.01 at \(F=\ln[8/(0.01\pi^2)]/\pi^2=0.44532\), or 0.44532 s with the given gap. At this time the next contributing mode contains \(e^{-9\pi^2F}/9\), below \(10^{-17}\). At much earlier times several modes reconstruct the thin moving layer.
Problem 2 · Double the gap
The plate speed and liquid stay fixed while \(H\) doubles. Compare the 99% settling time, steady shear, and steady flow per unit width in the two gaps.
Work through the solution
The dimensionless solution reaches the same settling criterion at the same \(F\). Since \(t=FH^2/\nu\), the wider gap takes four times as long, about 1.78 s. The steady gradient is \(U/H\), so its shear halves to 0.36 Pa. The steady flow is the area under a triangle of height \(U\) and width \(H\), namely \(UH/2\). It doubles to \(8.0\times10^{-4}\) m\(^2\)/s.
Interactive calculation · Startup couette
Change the physical and numerical inputs of the notebook model. Compare the updated curves and balance checks with the recorded notebook figures. Each plot uses the same equations and assumptions documented in that notebook; its readout names any analytical or reduced-model reference.
Interactive calculation · Startup shear
Change the physical and numerical inputs of the notebook model. Compare the updated curves and balance checks with the recorded notebook figures. Each plot uses the same equations and assumptions documented in that notebook; its readout names any analytical or reduced-model reference.
Momentum, motion and transport in fluids · 6. How far upstream does a downstream water level matter?
A depth gauge downstream of a change in bed level measures a local state. Predict the depth one kilometre upstream by combining energy, cross-section geometry and a resistance law, then fit the roughness against independent uniform-flow readings.
Separate normal depth and critical depth
Consider steady flow at discharge \(Q\) in a long prismatic rectangular channel of width \(b\). Depth \(y\) sets area \(A=by\), wetted perimeter \(P=b+2y\) and hydraulic radius \(R=A/P\). For a long reach of uniform depth, weight down the slope balances wall shear over the wetted perimeter. If \(S_0=-dz_b/dx\) is the bed slope, the force balance gives \(\tau_0=\rho g R S_0\). A resistance relation from measurement closes this balance. In SI units the Manning convention is
Normal depth \(y_n\) solves \(S_f=S_0\). Roughness \(n\) has units s m⁻¹ᐟ³. The equivalent Chézy form \(U=C\sqrt{R S_f}\) has \(C=R^{1/6}/n\) for the same prediction. Critical depth follows from specific energy \(E=y+Q^2/(2gA^2)\) at fixed discharge. Differentiating gives \(1-Q^2 b/(gA^3)=0\) at \(y_c\). The critical condition contains no roughness. For \(b=4\) m, \(Q=6\) m³/s, \(S_0=0.001\) and \(n=0.030\), \(y_n=1.556\) m while \(y_c=0.612\) m. This bed is mild for the specified discharge.
Derive an evolution equation in space
Assume hydrostatic pressure, negligible local losses, unit velocity-energy coefficient and a sufficiently gentle surface slope. Along increasing downstream distance the energy head drops by \(S_f\) per metre. Differentiating \(H=z_b+y+Q^2/(2gA^2)\) and using \(dA/dy=b\) gives
A downstream weir may impose a subcritical stage. For \(y>y_n>y_c\) we have \(S_f<S_0\) and \(Fr<1\), so \(dy/dx>0\). The water is deeper toward the control and approaches normal depth upstream. Integrate toward decreasing \(x\) starting at the measured stage. Replacing \(R\) by \(y\) assumes a very wide channel, which the 4 m section does not justify at these depths. Close to \(Fr=1\) the denominator signals the limit of a smooth slowly varying profile. A jump requires its own momentum treatment.
Separate resistance calibration from the boundary condition
The notebook first fits one roughness to four synthetic uniform discharge measurements and then holds it fixed for two downstream controls. The fitted \(n=0.03001\) gives depths of 1.605 m and 1.745 m one kilometre upstream of outlet depths of 1.8 and 2.2 m. The downstream 0.4 m difference has decayed substantially and still leaves an observable upstream effect.
Interactive experiment · Change a downstream control and recompute its upstream reach
The live calculation integrates the depth equation upstream with fourth-order Runge–Kutta steps of 2 m. Keep the default discharge and roughness, move the outlet stage from 1.8 to 2.2 m and compare depths 1 km upstream. Next change roughness: normal depth moves, while critical depth stays fixed. Changing discharge moves both reference depths.
The channel remains 4 m wide with bed slope 0.001. All available input combinations stay subcritical, where a downstream stage can influence the upstream reach. The plotted coordinate increases upstream, so its derivative has the opposite sign to the downstream equation. The notebook below fits roughness with OneSimulation before integrating two profiles; the browser lets you explore the consequences of prescribing that coefficient directly.
Continue in the OneSimulation notebook · Download its Python model
OneSimulation experiment · Two downstream stages produce different upstream profiles at the same calibrated roughness
Run the notebook with OneSimulation 0.2.0, NumPy, SciPy and Matplotlib. Change the input data and compare your run with the recorded result.
"""Infer Manning roughness from uniform flow, then predict a subcritical backwater."""
import numpy as np
import matplotlib.pyplot as plt
from scipy.integrate import solve_ivp
from onesim.numerics.nonlinear import LeastSquares
width, slope, discharge, gravity = 4.0, 0.001, 6.0, 9.81
measured_depth = np.array([0.7,0.85,1.0,1.15]) # m
def section(depth):
area = width*depth
return area, area/(width+2*depth)
def uniform(depth, roughness):
area, radius = section(depth)
return area*radius**(2/3)*np.sqrt(slope)/roughness
measured_flow = uniform(measured_depth,0.030) + np.array([0.02,-0.03,0.02,-0.01])
fit = LeastSquares().solve(lambda n: uniform(measured_depth,n[0])-measured_flow,
[0.025], bounds=([0.010],[0.08]))
roughness = fit.x[0]
def depth_gradient(x, y):
area,radius = section(y)
friction = (roughness*discharge/(area*radius**(2/3)))**2
froude_squared = discharge**2*width/(gravity*area**3)
return (slope-friction)/(1-froude_squared)
fig, ax = plt.subplots(figsize=(6.4,3.7), layout="constrained")
print(f"fitted Manning n = {roughness:.5f} s/m^(1/3)")
for boundary in [1.8, 2.2]:
x = np.linspace(0,-1000,250)
sol = solve_ivp(depth_gradient,[0,-1000],[boundary],t_eval=x,rtol=1e-9,atol=1e-10)
assert sol.success
print(f"outlet {boundary:.1f} m: depth 1 km upstream = {sol.y[0,-1]:.3f} m")
ax.plot(-sol.t,sol.y[0],label=f"Outlet depth {boundary:.1f} m")
ax.set(xlabel="Distance upstream from control (m)",ylabel="Flow depth (m)")
ax.legend()
plt.show()Reference run
fitted Manning n = 0.03001 s/m^(1/3) outlet 1.8 m: depth 1 km upstream = 1.605 m outlet 2.2 m: depth 1 km upstream = 1.745 m

Why two depth measurements do not always identify roughness
Near normal depth, the water surface changes slowly. Bed-slope bias, discharge error and roughness can produce similar residuals over a short reach. Calibrating against uniform measurements at more than one discharge gives an independent constraint before fitting the backwater.
Exercises on hydraulic controls
Two channels have the same discharge and width. Only the Manning coefficient is changed. Which characteristic depth changes?
Worked solution
Critical depth is fixed by discharge and geometry. Increasing roughness lowers discharge capacity at fixed depth and slope, so normal depth must increase to carry the same discharge. An altered resistance can move the flow into a different profile class.
A subcritical section has \(y=2.0\) m in the example. Estimate the slope before integrating.
Worked solution
Here \(A=8\) m², \(R=1\) m, \(S_f=(0.03\times6/8)^2=0.0005063\) and \(Fr^2=36(4)/(9.81\times512)=0.0287\). Thus \(dy/dx=0.000508\) m/m. Extrapolating this local slope for a kilometre ignores its variation with depth.
Further reading · Gerhart, Hochstein and Gerhart, Munson, Young and Okiishi’s Fundamentals of Fluid Mechanics, 9th ed., Sections 10.3–10.6.
Momentum, motion and transport in fluids · 7. How can a constant-area duct choke?
A nozzle reaches a sonic state by changing area. A straight pipe can approach the same Mach number through friction or through heating. The two cases conserve different combinations of stagnation properties.
Choose the wall process before eliminating variables
Take a steady one-dimensional calorically perfect gas with \(G=\rho u\) constant, no shaft work and constant pipe area. Write \(M=u/\sqrt{\gamma RT}\), \(h_0=c_pT+u^2/2=c_pT_0\). An adiabatic wall fixes \(T_0\) even when wall friction creates entropy. A frictionless wall which supplies heat changes \(T_0\) while preserving the axial momentum flux \(p+\rho u^2\). Measure static and stagnation variables independently to distinguish these processes.
Integrate the frictional momentum loss
For hydraulic diameter \(D\) define the Darcy factor by \(\tau_w=f_D\rho u^2/8\). A slice has perimeter-to-area ratio \(4/D\), so momentum balance is \(dp+\rho u\,du+f_D\rho u^2dx/(2D)=0\). Differentiate constant \(G\) and \(T_0\) to obtain \(d\rho/\rho=-du/u\) and \(dT/T=-(\gamma-1)M^2du/u\). Substitute in \(dp/p=d\rho/\rho+dT/T\) and \(dM/M=du/u-dT/(2T)\):
Integrate from inlet \(M_1\) to outlet \(M_2\). Defining the remaining distance to sonic conditions by \(F(1)=0\) gives
For air with \(\gamma=1.4\), \(M_1=0.4\), \(M_2=0.7\), the two function values are 2.30849 and 0.20814. With \(D=0.050\) m and constant \(f_D=0.020\), the required length is 5.25 m. The maximum length at the stated inlet condition is 5.77 m. A longer duct requires different inlet conditions or mass flow. A quoted Fanning coefficient is one quarter of this Darcy coefficient.
Remove friction and allow heat transfer
The constant momentum flux becomes \(p(1+\gamma M^2)=p^*(1+\gamma)\), where the star denotes the sonic state on this same momentum line. Use mass conservation and the ideal-gas law to get \(T/T^*=[(1+\gamma) M/(1+\gamma M^2)]^2\). Multiply by the ratio between stagnation and static temperatures at each state to obtain
For the same inlet and outlet Mach numbers this ratio rises from 0.52903 to 0.90850. If \(T_{01}=350\) K, the outlet stagnation temperature is 601.1 K. The heat added per unit mass for \(c_p=1005\) J/(kg K) is approximately 252 kJ/kg. The sonic-line maximum \(T_0^*=661.6\) K places an upper bound on additional heat at the fixed inlet state. In the friction case the stagnation temperature remained at 350 K throughout.
Why both subsonic cases accelerate
Mass flux per area is fixed. The change of pressure and temperature required by momentum and wall conditions reduces density on these subsonic paths. Velocity rises. Supersonic and subsonic branches require explicit tracking when inverting a sonic-reference relation.

Interactive calculation · Approach a sonic state by two different wall processes
Vary the heat-capacity ratio and inlet Mach number. Compare the remaining friction-length budget with the heat addition required to reach the Rayleigh sonic reference. The two dimensionless ordinates have different definitions.
Exercises on distinguishing mechanisms
A frictional pipe with the worked inlet already carries gas at Mach 0.7 at a pressure tap. How much more straight pipe reaches the mathematical choking limit?
Worked solution
The remaining friction length is \(D F(0.7)/f_D=0.520\) m. This calculation assumes the same Darcy factor up to the sonic state.
A well-insulated pipe test gives a large stagnation-pressure loss but nearly identical measured stagnation temperatures. Could a frictionless Rayleigh model with steady net heating explain both quantities?
Worked solution
Net heating necessarily raises \(h_0\). The nearly unchanged stagnation temperature supports adiabatic frictional loss or another adiabatic irreversible process. Static temperatures alone do not distinguish acceleration from wall heat.
Further reading · Gerhart, Hochstein and Gerhart, Munson, Young and Okiishi’s Fundamentals of Fluid Mechanics, 9th ed., Sections 11.8–11.9.
Energy, entropy and mechanical response
Close a steady-flow energy balance, then determine which pressure or temperature change reveals an irreversible process. Connect a film force to a moving bearing.
- Open systems, enthalpy and steady-flow devices
- Entropy, irreversibility and useful-work loss
- Useful work and exergy destruction
- Diffusion with a stationary carrier gas
- Hydrodynamic lubrication and sliding bearings
- From cut forces to local equilibrium
- Action density, stress waves and the boundary that reflects them
- From binary collisions to the Boltzmann equation
Solving transport while conserving mass
Follow control-volume reasoning onto a grid. Compare diffusion, interface fluxes and advective remapping. Check how a travelling perturbation moves at different resolutions.
- Flux differences for an elliptic balance
- Finite volumes and moving fronts
- Time-dependent diffusion
- Interfaces, contact resistance and Robin data
- Cell Péclet number and monotonicity
- What a periodic grid does to a decaying Fourier mode
- Moving a cell average without inventing or losing material
- Splitting a stiff relaxation from a slowly varying drive
- Transport coefficients from equilibrium fluctuations
Applied study
Connect a growing boundary layer to wall shear, momentum loss and drag.
How does a surface slow down a moving fluid?
Upstream of a smooth plate, every parcel in a uniform stream moves at speed \(U\). At the plate the no-slip condition brings the fluid to rest. Momentum diffuses across the flow while the stream carries it downstream, so the region slowed by the wall thickens with distance. The wall shear determines how much power is needed to move a plate through the fluid.
Consider steady two-dimensional incompressible laminar flow at constant density \(\rho\), dynamic viscosity \(\mu\) and zero streamwise pressure gradient. Measure \(x\) from the leading edge and \(y\) normal to the plate. When the viscous layer is thin relative to \(x\), the streamwise momentum and continuity equations reduce to
At the wall \(u=v=0\), while \(u\) approaches \(U\) far above it. Balancing \(U^2/x\) with \(\nu U/\delta^2\) gives the thickness scale \(\delta\sim\sqrt{\nu x/U}\). The thickness increases downstream even though \(\delta/x\) falls. Doubling the speed gives the fluid less time to diffuse momentum before it reaches the observation point.
Relate a measured velocity slope to drag
Profiles at different stations have nearly the same shape when plotted against \(\eta=y\sqrt{U/(\nu x)}\). The laminar Blasius solution gives a wall slope \(\partial_y u|_0=0.332\,U\sqrt{U/(\nu x)}\). Therefore, with \(Re_x=Ux/\nu\),
The last thickness is the height at which \(u=0.99U\). Integrating \(\tau_w\) from the leading edge to length \(L\) gives the drag on one face per unit width,
The mean friction coefficient over the plate is twice the local coefficient at its trailing edge. Surface roughness, transition to turbulence and strong pressure gradients change this result.
Worked example · Sample a plate halfway along
Use \(U=1.0\) m/s, \(\rho=1.0\,\mathrm{kg/m^3}\), \(\mu=10^{-4}\,\mathrm{Pa\,s}\) and \(x=0.50\) m. Then \(\nu=10^{-4}\,\mathrm{m^2/s}\) and \(Re_x=5000\). The 99% thickness is 35.4 mm, the friction coefficient is 0.00939, and the shear stress is
At \(x=1.00\) m the layer has grown to 50 mm and the wall shear has fallen to 0.00332 Pa. The amount of fluid affected has increased while the near-wall velocity gradient has weakened.
Transfer problem · Use a pressure drop to infer pipe flow
In a sufficiently long straight pipe of radius \(R\), the viscous regions growing from the walls merge and the velocity profile stops changing downstream. For a fluid cylinder of radius \(r\) and length \(L\), the pressure force \(\Delta p\,\pi r^2\) balances the resisting shear force \(2\pi r L|\tau|\). Hence \(|\tau|=\Delta p\,r/(2L)\). Since \(du/dr=-|\tau|/\mu\), integration with \(u(R)=0\) gives
Integrating over circular rings yields
A water line has \(R=5.0\) mm, \(L=2.0\) m, \(\mu=0.0010\,\mathrm{Pa\,s}\) and \(\rho=1000\,\mathrm{kg/m^3}\). Delivering \(Q=1.0\times10^{-6}\,\mathrm{m^3/s}\) requires \(\Delta p=8.15\) Pa over the developed portion. The mean speed is \(Q/(\pi R^2)=0.0127\) m/s and the diameter-based Reynolds number is 127, consistent with laminar flow. Halving the pipe radius at fixed flow multiplies the required pressure by sixteen. Compare the derivation for a parallel-plate channel.
Exercises
1. Choose an appropriate force measurement
A 0.20 m wide plate is exposed on one face from its leading edge to \(L=1.00\) m under the conditions above. What force should a balance measure? What bias would follow from using the trailing-edge wall shear across the entire plate?
Show the drag estimate
The integrated force is
Using the final local shear gives only \(0.00332(1)(0.20)=0.000664\) N. Wall shear varies as \(x^{-1/2}\), so the leading part contributes more drag per unit length.
2. Distinguish dimensionless and dimensional changes
At the same station, double the free-stream speed without changing the fluid. Predict the changes in \(\delta_{99}\), \(c_f\), \(\tau_w\) and power lost to skin friction at fixed plate length.
Show the scaling argument
Both thickness and friction coefficient scale as \(U^{-1/2}\), giving a factor 0.707. Dimensional shear includes \(U^2\), hence grows by \(2^{3/2}=2.83\). Drag has the same speed exponent and required power is \(DU\), which grows by \(2^{5/2}=5.66\).
OneSimulation laboratory
Measure boundary-layer growth from a velocity profile
Compare recorded OneSimulation runs on this page. To test your own inputs, download the notebook and model files and run the model in an activated OneSimulation environment.
The OneSimulation domain begins 0.2 m downstream of the leading edge. Use the row labelled \(x=0.50\) m, which already includes that offset. The baseline uses stream=1.0 m/s, density=1.0 kg/m³ and dynamic_viscosity=1.0e-4 Pa·s.
- Double
streamto2.0m/s. Rebuild the model so the imposed inlet profile also changes. Expect a thickness near 25 mm and smaller \(c_f\), even though the dimensional wall stress increases. - Restore
stream=1.0and doubledynamic_viscosityto2.0e-4Pa·s. At unchanged density, expect a thickness near 50 mm and \(c_f\) near 0.0133. Compare the departures from the similarity approximation with the baseline.
| Free stream and viscosity | Thickness (mm) | Friction coefficient (×10⁻³) |
|---|---|---|
| 1 m/s, 0.10 mPa·s | 35.84 | 9.188 |
| 2 m/s, 0.10 mPa·s | 25.19 | 6.559 |
| 1 m/s, 0.20 mPa·s | 51.03 | 12.878 |

View the OneSimulation flat-plate model and its velocity profiles.
Download experiment files (ZIP) Extract the files together and open blasius_flat_plate.ipynb in a local OneSimulation environment.
Interactive reference for the OneSimulation laboratory
Reintegrate the Blasius similarity profile and vary its dimensional scales. Compare this laminar1D similarity reference with the spatial OneSimulation run.
Problem sheet 4 · Infer viscosity from the edge of a boundary layer
Notation and assumptions
Read each defining equation with its assumptions and units, then follow the link to the argument that gives the equation its meaning.
Capillary pressure
Principal curvatures carry signs set by the chosen normal. A cylindrical interface contributes only one finite principal curvature.
Froude number
For shallow rectangular flow with gravity waves this compares material speed to wave speed. Critical depth occurs when the two are equal.
Head loss
This is an irreversible loss expressed as a length. A static pressure change can also include reversible changes of speed or elevation.
Material acceleration
A fluid parcel can accelerate as it follows a steady but spatially varying velocity. A probe fixed in space measures only the local time history.
Derivation · Velocity fields, flow rates and conservation of mass
Reynolds number
Choose speed and length scales appropriate to the geometry. Matching this ratio compares inertial and viscous terms under the stated nondimensionalisation.
Derivation · Dynamic similarity, boundary layers and model tests
Vorticity
Its units are reciprocal seconds. Circulation around a closed loop integrates the corresponding vorticity flux when the interior is regular.
Further reading
Look for the distinction between an integral momentum balance and a local velocity field. Rework the pipe and boundary-layer cases after changing the control surface. MIT · Fluid Dynamics
Use the advanced problems to practise identifying the dimensionless groups and boundary conditions that survive a limiting process. MIT · Advanced Fluid Mechanics