Fundamentals / Mechanical engineering / Fluid mechanics

Bernoulli head, losses and pump duty

Build a mechanical-energy balance between two stations and distinguish a recoverable pressure change from irreversible loss.

From first principles

Derive mechanical head along a streamline

Take steady inviscid flow of constant-density liquid under gravity. Along a streamline use distance \(s\), speed \(V\) and elevation \(z\) positive upwards. Tangential acceleration of a parcel is \(V\,dV/ds\) because the parcel moves from one position to the next. Pressure gradient and gravity provide the tangential force per unit volume. Dividing their balance by density gives

\[V\frac{dV}{ds}=-\frac1\rho\frac{dp}{ds}-g\frac{dz}{ds}.\]

Each term is a derivative along the path. Integrating between two positions shows that their sum, written as energy per unit mass, is conserved under the stated assumptions.

\[\frac p\rho+\frac{V^2}{2}+gz=\text{constant along a streamline}.\]

Dividing by \(g\) converts all terms into lengths called heads. In a pipe system one measures added pump head \(H_p\), removed turbine head \(H_t\) and irreversible loss \(h_L\) to form a section-to-section engineering balance. For uniform profiles this reads

\[H_1+H_p=H_2+H_t+h_L,\]
\[H_j=p_j/(\rho g)+V_j^2/(2g)+z_j .\]

This distinguishes a reversible pressure drop associated with acceleration from a loss of total mechanical head.

Background · Head loss
\[h_L=\Delta p_{\rm loss}/(\rho g)\]

This is an irreversible loss expressed as a length. A static pressure change can also include reversible changes of speed or elevation.

Derivation and applications

Derive an ideal Venturi flow reading from two pressure taps

A narrowing can measure flow by reversibly trading pressure for speed. Take a horizontal Venturi meter carrying steady, incompressible liquid from a developed upstream section of area \(A_1\) into a throat of area \(A_2\). For an ideal first model assume uniform velocity at the two taps, negligible viscous loss between them, and no pump or turbine between stations. Pressure taps register static pressure. Define \(\beta=d_2/d_1\) for geometrically circular sections and use continuity to eliminate upstream speed.

\[V_1=\frac{A_2}{A_1}V_2=\beta^2V_2,\]
\[p_1-p_2=\frac{\rho}{2}(V_2^2-V_1^2).\]

The squared velocity is the source of the fourth power of diameter ratio. Substituting the continuity expression and multiplying throat speed by throat area gives the ideal meter law.

\[Q_{\rm id}=A_2\sqrt{\frac{2(p_1-p_2)}{\rho(1-\beta^4)}} .\]

In an installed meter a calibrated discharge coefficient \(C_d\) relates actual flow to this model. At fixed geometry, density and coefficient, logarithmic differentiation produces a useful uncertainty relation for pressure-transducer readings.

\[Q=C_d Q_{\rm id},\]
\[\frac{dQ}{Q}=\frac12\frac{d(\Delta p)}{\Delta p},\]
\[\Delta p=p_1-p_2.\]

The pressure difference between upstream tap and throat is larger than the permanent loss measured after the diffuser. Estimating pump power from the meter differential would therefore include recoverable pressure. At very small flow, a fixed pressure offset has a particularly large relative effect.

Worked example

Translate a pressure reading into discharge

A water meter has \(d_1=80.0\) mm, \(d_2=40.0\) mm, \(\rho=1000\) kg/m³ and \(C_d=0.980\). A 3.00 kPa differential corresponds to ideal throat speed \(\sqrt{6/0.9375}=2.53\) m/s. Actual discharge is

\[0.980\pi(0.0200)^2(2.53)=3.12\,\mathrm{L/s}.\]

A 30 Pa differential error represents one percent of the measured drop, giving approximately 0.5 percent flow error.

Change the inputs and inspect this calculation below

Second application

Calibrate a second meter against a collection tank

A meter with \(\beta=0.600\) and \(A_2=600\) mm² gives 2.00 kPa differential for a liquid of density 800 kg/m³. Its ideal flow is

\[0.000600\sqrt{4000/[800(1-0.6^4)]}=1.44\,\mathrm{L/s}.\]

Collecting 14.0 L in 10.0 s indicates 1.40 L/s, hence \(C_d=0.974\) after using unrounded intermediate values. Repeating at other flow rates tests whether one constant coefficient is appropriate.

Interactive calculation · Change the inputs of this example

Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.

Integrate the acceleration along a streamline

A nozzle can lower static pressure while increasing speed. A valve can also lower pressure, yet recover little useful speed downstream. To separate the mechanisms, start from a steady, inviscid streamline in constant-density flow. Project Newton’s equation along its tangent \(s\), with gravity acting downward. The acceleration in that direction is \(u\,du/ds\), giving \(\rho u\,du=-dp-\rho g\,dz\). Integration between points on that streamline gives \(p/\rho+u^2/2+gz=\) constant.

The three terms have units J/kg. Dividing by \(g\) measures the same energies as equivalent lengths of fluid column, called pressure head, velocity head and elevation head. A rise in speed at constant elevation can be paid for by a drop in static pressure even in lossless flow. Bringing such a stream to rest along a short, nearly lossless streamline would convert velocity head back into stagnation pressure. An irreversible loss reduces that recoverable total.

Add distributed losses and machinery

For a steady incompressible stream between stations with approximately uniform profiles, a pump supplies head \(H_p\) and a turbine extracts head \(H_t\). Viscous losses \(h_L\) appear as mechanical energy converted into internal energy. With endpoints numbered in the flow direction the energy balance is

\[\frac{p_1}{\rho g}+\frac{\bar u_1^2}{2g}+z_1+H_p=\frac{p_2}{\rho g}+\frac{\bar u_2^2}{2g}+z_2+H_t+h_L .\]

For a noticeably nonuniform profile, multiply each velocity-head term by the kinetic-energy correction \(\alpha=\int_Au^3dA/(A\bar u^3)\). It differs from the momentum correction because energy flux weights the cube of velocity. Long straight pipes are commonly modelled with the Darcy loss \(f_D(L/D)\bar u^2/(2g)\) and fittings with \(K\bar u^2/(2g)\). State which pipe diameter supplies the reference velocity for each coefficient.

Lift water between open tanks

Two large vented reservoirs differ in elevation by 8.0 m. Water flows at \(Q=0.010\,\mathrm{m^3/s}\) through 40 m of 80 mm diameter pipe. Use a supplied Darcy friction factor 0.025 and total fitting coefficient 3.0, including entrance and exit losses. Both free surfaces have atmospheric pressure and negligible velocity. The pipe area is \(5.03\times10^{-3}\) m², giving mean speed 1.99 m/s and velocity head 0.202 m. Friction and fittings dissipate \([0.025(40/0.080)+3.0]0.202=3.13\) m. The pump therefore supplies 11.13 m head.

The hydraulic power is \(\rho gQH_p=1.09\) kW for \(\rho=1000\) kg/m³. A pump with efficiency 0.70 at this duty requires 1.56 kW of shaft power. Elevation work alone would predict 0.785 kW hydraulic, and electrical input would also require the motor and drive efficiencies. These differences reflect which boundary is used for the energy balance.

Find the intersection with the pump characteristic

If coefficients are treated as fixed, the system head here has the form \(H_{\rm sys}=8+BQ^2\). Doubling the flow quadruples the losses, not the elevation rise. A real pump produces a head that depends on flow rate and rotational speed. Its steady operating point is where available head equals required head. Partially closing a valve increases \(B\); it does not directly prescribe a particular flow. Readjusting pump speed changes its characteristic instead. In a real design recheck friction factor and efficiency at the new rate. At low Reynolds number, where laminar friction factor varies inversely with speed, the distributed loss becomes linear rather than quadratic in flow.

Check the absolute pressure on a pump inlet

A pump inlet sits 3.0 m above an open water reservoir. At a particular duty the suction-line speed is 2.0 m/s and the loss between reservoir and inlet is 0.60 m. Atmospheric pressure is 101 kPa. Applying the mechanical energy balance upstream of the impeller gives absolute inlet pressure \(101000-1000(9.81)(3.0+0.60)-1000(2.0)^2/2=63.7\,\mathrm{kPa}\). If the supplied vapour pressure is 2.3 kPa, this tapping remains above it. Pressure may fall further inside the impeller. Evaluating cavitation margin requires the pump’s suction requirement at the actual duty and an absolute pressure reference; a negative gauge pressure at the tapping alone does not establish cavitation.

Locate the critical depth from a constrained energy minimum

In open-channel flow the atmosphere fixes the free-surface pressure, while the depth and speed can both adjust. Consider a rectangular channel of constant width with slowly changing bed elevation \(z_b\). Define the discharge per unit width \(q=vy\) and use the bed as the local elevation datum. With nearly hydrostatic pressure and approximately uniform section velocity, the mechanical head relative to the bed is \(E(y)=y+q^2/(2gy^2)\). This specific energy is finite at a given depth but diverges both for a very shallow stream at fixed discharge and for a very deep stream.

At fixed \(q\), differentiate with respect to \(y\): \(dE/dy=1-q^2/(gy^3)\). The stationary depth is \(y_c=(q^2/g)^{1/3}\), its Froude number is one, and the second derivative \(3q^2/(gy^4)\) is positive. The minimum value is

\[E_c=3y_c/2.\]

For any specific energy above this minimum two positive depths are possible. One is deep and slow and the other shallow and fast. One must know the upstream flow regime and the physical control to choose a branch.

Across a smooth low hump with negligible loss the total head \(z_b+E\) remains constant. Raising the bed reduces the specific energy available at the crest. On the deep branch depth decreases towards critical, whereas on the shallow branch depth increases towards it. These opposite trends follow from the sign of \(dE/dy\). Neither branch can pass below \(E_c\) at the prescribed discharge.

Predict when a raised bed changes the upstream water level

Water enters a wide rectangular flume at \(y=0.80\,\mathrm m\) and \(v=1.0\,\mathrm{m/s}\), giving \(q=0.80\,\mathrm{m^2/s}\) and upstream specific energy \(E_1=0.8510\,\mathrm m\). The critical depth is \((0.64/9.81)^{1/3}=0.4025\,\mathrm m\), so \(E_c=0.604\,\mathrm m\). The largest ideal bed rise that leaves the upstream state unchanged is

\[0.851-0.604=0.247\,\mathrm m.\]

For a smaller 0.15 m bed rise the crest must have \(E=0.7010\,\mathrm m\). Solving \(y+0.03262/y^2=0.7010\) on the deep branch gives approximately 0.614 m, which can be checked by substitution. Speed increases to about 1.30 m/s while the stream remains subcritical.

Raise the crest instead by 0.30 m. The unchanged upstream level would provide only 0.551 m specific energy, less than the minimum. If discharge stays fixed, the upstream surface must rise until at least \(E_1=0.30+0.604=0.904\,\mathrm m\) is available. The subcritical solution upstream is then approximately 0.860 m depth, a rise of about 60 mm. The physical limitation is the minimum section energy for the prescribed flow, not a loss of mass. Adding appreciable crest losses would require an even larger upstream head to sustain the same discharge.

A depth gauge right at a critical crest is relatively insensitive as an energy measurement: the first derivative \(dE/dy\) vanishes there. Conversely, inferring depth from a noisy measured head becomes sensitive near the minimum because the inverse slope becomes large. Measurements upstream and downstream help identify which of the two nearby depth branches is physically present.