From first principles
Relate a support reaction to momentum carried by a stream
Newton's second law applies to a fixed set of fluid particles: external force equals the time derivative of their momentum. In a pipe bend it is easier to observe a stationary control volume that particles continually enter and leave. The rate of change for the material particles consists of storage in that volume plus the net rate at which momentum crosses its boundary.
The dot product determines whether mass crosses inwards or outwards, while the other velocity factor retains the direction of the momentum carried. For steady uniform inlet and outlet sections, the flux integral reduces to
Pressure pushes inward normal to each open section, so its contribution must be included before solving for the wall force. The force of the fluid on the bend is opposite to the wall's force on the fluid. Equal inlet and outlet speed can still give a substantial support load when their directions differ.
Derivation and applications
Derive the irreversible head loss across a sudden expansion
A sudden enlargement slows a liquid and partly restores static pressure. Consider steady incompressible flow from area \(A_1\) into area \(A_2>A_1\) in a horizontal pipe. Choose the downstream section after mixing has produced an approximately uniform velocity again. Approximate both station profiles as uniform, neglect wall shear over the short control volume and take the mean pressure on the annular shoulder to be the upstream pressure \(p_1\). Mass conservation makes the two mean speeds \(V_1,V_2\) proportional to inverse area.
The inlet and shoulder together contribute \(p_1A_2\) to the axial pressure force. Rearranging the momentum balance gives a positive downstream pressure rise, despite the separated mixing region.
Insert that pressure rise into the mechanical energy balance. The difference between kinetic energy released and pressure recovered is the specific energy dissipated in mixing, expressed below as a head of flowing liquid.
This result tends to zero quadratically as the area change vanishes. A gradual diffuser would require a different shoulder-pressure and separation model. Pressure recovery can thus coexist with positive mechanical-energy loss and its measurement alone does not provide the loss.
Worked example
Audit an abrupt pipe enlargement
Water moving at 3.00 m/s enters a pipe section with three times the area. Its final speed is 1.00 m/s. Taking \(\rho=1000\) kg/m³, the pressure rises by \(1000(1.00)(2.00)=2.00\) kPa. The kinetic pressure falls by 4.00 kPa; the missing 2.00 kPa is a head loss of 0.204 m. For 6.00 L/s, the rate of mechanical energy dissipation is \(Q\rho g h_L=12.0\) W.
Change the inputs and inspect this calculation below
Second application
Recover the enlargement ratio from a head test
Another rig measures \(V_1=2.50\) m/s and \(h_L=0.0800\) m. Taking the positive speed drop yields
The inferred area ratio is \(A_2/A_1=V_1/V_2=2.00\) to the stated precision. The expected water pressure rise is about 1.56 kPa, a separately measurable check on the shoulder-pressure assumption.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Momentum crosses the boundary with the mass
A pipe bend can exert a substantial force on its supports even when its inlet and outlet speeds agree. Momentum has direction. Turning a stream requires force and gives the fitting an equal and opposite load. Enclose the fluid inside the fitting in a fixed control volume. The external forces include wall traction, pressure on the control surfaces and body forces such as gravity.
A surface element transports mass per second \(\rho(\mathbf u\cdot\mathbf n)dA\). Multiply by the local velocity to obtain momentum per second. Newton’s second law applied to the control volume reads
For a steady fitting with nearly uniform inlet and outlet velocities this reduces to a sum of outgoing \(\dot m\mathbf u\) minus incoming \(\dot m\mathbf u\). Use one fixed set of axes even as pipe directions change. Pressure always pushes into the control volume, whereas the flux carries the direction of the local velocity, including its sign on the chosen axis.
Include the end pressures explicitly
Take a horizontal bend turning water from the positive \(x\) direction to the positive \(y\) direction. The inlet and outlet areas are each 0.010 m² and \(Q=0.040\,\mathrm{m^3/s}\). Their speeds are both 4.0 m/s and \(\dot m=40\) kg/s. The net outward momentum flux vector is \((-160,+160)\) N. Let the gauge pressures be 90 kPa at inlet and 80 kPa at outlet. Pressure pushes +900 N in \(x\) through the inlet and −800 N in \(y\) through the outlet.
Let \(\mathbf W\) be the fitting’s wall force on the enclosed fluid, with external atmospheric effects accounted for consistently using gauge pressures. Then \(\mathbf W+(900,-800)=(-160,160)\) N, giving \(\mathbf W=(-1060,960)\) N. The fluid’s net gauge load on the fitting is the opposite, \((1060,-960)\) N, of magnitude 1.43 kN. Supports plus connected pipework must provide the opposite force for a stationary fitting, in addition to carrying the weight of hardware and fluid. The strongest contribution here stems from the pressure terms, despite the conspicuous turn in velocity.
Recover momentum from a nonuniform profile
A flow meter usually measures \(Q\), not \(\int u^2dA\). At a plane normal to a unidirectional profile define \(\beta=\int u^2dA/(A\bar u^2)\). Then the axial momentum rate is \(\beta\rho Q\bar u\). Uniform flow gives \(\beta=1\). For a developed laminar circular pipe \(u=2\bar u[1-(r/R)^2]\); inserting \(dA=2\pi r\,dr\) in the integral gives \(\beta=4/3\). The largest velocities carry a disproportionate share of momentum. If one bend cross-section admits strong swirl or backflow, resolve vector fluxes instead of applying a single profile coefficient.
Recognise an open-stream boundary
A free jet at atmospheric pressure strikes a fixed flat plate normal to its axis and turns into a thin sheet that leaves sideways. Neglecting rebound and friction far from the impact, the outgoing axial momentum flux is zero. For water flowing at 10 m/s through a 20 mm diameter nozzle, \(\dot m=3.14\) kg/s, so the axial force on the plate is 31.4 N. Both the incoming and outgoing free-stream control surfaces have zero gauge pressure. The plate force then follows entirely from the change of momentum. A nozzle bolted to a pressurised pipe would require different pressure forces even if it produced exactly the same free jet.
A jet catches a moving vane
Consider a single flat vane moving steadily in the jet direction at speed \(u\). In the vane frame the arriving volume rate is \(A(V-u)\) and the incoming streamwise relative velocity is \(V-u\). If the jet spreads tangentially across the face, the resulting normal force is \(\rho A(V-u)^2\). For water, \(A=2.0\,\mathrm{cm^2}\), \(V=10\) m/s and \(u=4\) m/s, this gives 7.2 N. Its mechanical power on the moving vane is \(Fu=28.8\,\mathrm W\). Using the stationary volume rate would count fluid parcels that the moving vane never catches.
Derive the two depths of a hydraulic jump
A hydraulic jump converts shallow fast open-channel flow into deeper slow flow over a short distance. Turbulent mixing dissipates mechanical energy, so applying an inviscid energy balance between the two uniform sections would miss its defining loss. Instead choose a control volume bounded by sections before and after the roller, the horizontal bed and the free surface. Approximate the velocity as uniform and the pressure distribution as hydrostatic at the two end sections. Atmospheric pressure cancels, and over the short reach assume the integral of bed friction is small compared with the pressure and momentum forces.
In a rectangular channel per unit width let the volume rate be \(q\), depths \(y_1,y_2\) and speeds \(v_i=q/y_i\). The horizontal pressure resultant per width is \(\rho g y_i^2/2\). Equating pressure force difference to momentum-flux change gives
One solution is the unchanged depth. Factoring out \(y_2-y_1\) for the nontrivial solution gives
With upstream Froude number \(Fr_1=v_1/\sqrt{g y_1}\), the downstream-to-upstream depth ratio becomes \([\sqrt{1+8Fr_1^2}-1]/2\). The deeper downstream branch occurs when \(Fr_1>1\). As \(Fr_1\to1\), the ratio tends to unity and the finite jump disappears.
Calculate the energy dissipated in a channel transition
A horizontal test channel carries water at \(y_1=0.20\,\mathrm m\) and \(v_1=4.0\,\mathrm{m/s}\). Its unit-width discharge is \(q=0.80\,\mathrm{m^2/s}\) and Froude number is
The depth ratio is about 3.57, giving \(y_2=0.714\,\mathrm m\) and \(v_2=0.80/0.714=1.12\,\mathrm{m/s}\). The downstream Froude number is about 0.42. These are conjugate depths for the specified momentum balance; the tailwater has to support the downstream depth for a stationary jump to sit at the chosen location.
Using specific mechanical head \(E=y+v^2/(2g)\), the inlet and outlet give 1.015 and 0.778 m respectively. The loss is approximately 0.237 m of water, or \(1000(9.81)(0.80)(0.237)=1.86\,\mathrm{kW}\) dissipated per metre of channel width. Substitution of the momentum relation into the energy difference gives
which is positive for the physical jump and approaches zero rapidly for a weak jump. This is a useful cross-check on a measured depth pair. If measurements are taken within the roller, pressure may be nonhydrostatic and velocity markedly nonuniform; using those sections in the simple end-state formula can produce an apparent energy or momentum imbalance.
Another discrimination comes from comparing the two depths with an upstream energy curve. At \(q=0.80\) m²/s, a downstream depth giving exactly the upstream energy would have to satisfy \(y+0.03262/y^2=1.015\). The deeper root is about 0.981 m, appreciably deeper than the momentum-predicted 0.714 m. Pairing those equal-energy depths would require an additional horizontal force or a different channel geometry to satisfy momentum. A smooth reversible change over a channel hump can conserve specific head while changing velocity and depth; a jump on a flat bed instead conserves the appropriate momentum function while dissipating head. Laboratory measurements of both levels are sufficient to distinguish the two idealisations.
Resolve the momentum force on a turning guide
A steady free water jet of mass flow 6 kg/s enters a smooth stationary guide at 20 m/s and leaves with the same speed at the indicated angle. Inlet and exit are at ambient pressure. Neglect weight for this short control volume. Reaction on the guide is the negative of the fluid momentum change.

Read values from the plot
| Outlet deflection (degrees) | Streamwise | Transverse | Resultant magnitude |
|---|---|---|---|
| 0 | 0 | 0 | 0 |
| 40 | 28.075 | −77.135 | 82.085 |
| 80 | 99.162 | −118.18 | 154.27 |
| 120 | 180 | −103.92 | 207.85 |
| 160 | 232.76 | −41.042 | 236.35 |
Interactive calculation · change the inputs of this example
Compare a right-angle turn with a complete reversal. The transverse force requires vector momentum, not just speed magnitude.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.