Keep the unsteady term in a parallel flow
Let \(y\) increase upward from a very broad, horizontal plate. The liquid is Newtonian and incompressible with constant kinematic viscosity \(\nu\); the plate moves parallel to itself with speed \(U\cos\omega t\). Ignore edges, any pressure gradient along the plate and transients left from starting the motion. By symmetry the velocity has a single component \(u(y,t)\). A parcel has no vertical speed and meets no streamwise velocity variation, so convective acceleration vanishes even though the motion is time dependent. Horizontal momentum balance on a slice of thickness \(dy\) compares its acceleration with the shear-stress difference on its two faces.
Velocity is prescribed at the plate by no slip and tends to zero far away. The same equation describes thermal diffusion with temperature in place of velocity. Here the quantity transferred is horizontal momentum, and a velocity gradient sets its transfer rate.
Read decay and phase from one complex root
Represent periodic velocity by the real part of \(\widehat u(y)e^{i\omega t}\). Inserting it into the equation gives
Since \((1+i)^2=2i\), the decaying branch of the solution has an exponent with equal real and imaginary parts.
Every increase in height by \(\delta\) divides the amplitude by \(e\) and delays the phase by one radian. This \(\delta\) is a scale rather than a physical edge. The unbounded solution requires the top and sidewalls to be far enough away for the amplitude there to be negligible. At five penetration depths it is less than one percent of its value at the plate.
Worked example · interpret a submerged velocity probe
In an oil with \(\nu=5.0\times10^{-5}\) m²/s, set \(f=2.00\) Hz and \(U=0.080\) m/s. Using \(\omega=2\pi f\) gives \(\delta=2.82\) mm. At 3.00 mm the predicted amplitude is
The phase lag is 1.06 rad or 0.0846 s. A synchronized velocity snapshot can therefore show nearly stationary liquid while the wall speed is large. A single instantaneous ratio generally differs from the ratio of fitted amplitudes.
Worked example · power delivered to the wall layer
The wall exerts on the fluid a tangential traction \(-\mu u_y(0,t)\). Its complex amplitude is \(\mu U(1+i)/\delta\). Only the in-phase part contributes to power averaged over a cycle, since averaging a product of two cosines gives one half of the cosine of their phase difference. Thus
For the same oil at density 900 kg/m³, \(\mu=0.045\) Pa s and the mean power is 0.0510 W/m². The positive value is consistent with viscous dissipation even though mean shear and mean speed separately vanish.
Freeze the phase at a quarter cycle and find the depth at which the velocity first changes sign away from the wall. Sweep the phase to distinguish that moving zero from the stationary amplitude envelope, then double the frequency and predict the new penetration depth.
A related OneSimulation calculation
The course flat-plate calculation provides a second momentum-diffusion example. Predict what doubling viscosity does to the measured layer thickness at a fixed downstream station, then compare the square-root scaling across the two geometries.
Tutorial · estimate a material property without a force sensor
At 1.00 Hz two probes spaced 2.00 mm vertically report fitted amplitudes in the ratio upper/lower = 0.500. Estimate \(\delta,\nu\), and the phase difference. Identify a measurement that would falsify this model even if the amplitude ratio agreed.
Use both the magnitude and phase predictions
The spacing divided by \(\delta\) is \(\ln2\), giving \(\delta=2.89\) mm. Then \(\nu=\omega\delta^2/2=2.62\times10^{-5}\) m²/s. The upper signal must lag by 0.693 rad, equivalent to 0.110 s. A substantial phase discrepancy suggests confinement, an unremoved transient or motion beyond a one-dimensional shear layer. Fitting both observables is a stronger test than assigning a viscosity to every amplitude pair.
Further reading · MIT 2.25, Stokes’ second problem (PDF)