From first principles
Derive the parabolic velocity profile between stationary plates
Consider steady fully developed flow between wide parallel plates at \(y=0\) and \(y=H\). Assume incompressible Newtonian fluid, constant viscosity \(\mu\), no slip, no variation across the channel width and no streamwise body force. Let \(G=-dp/dx>0\) drive flow in the positive \(x\) direction. Since the axial velocity depends only on \(y\), the convective acceleration is zero. A thin fluid layer balances pressure force against the change of shear stress across its thickness.
Integrate twice and apply zero velocity at both walls. The resulting velocity is largest halfway between the walls, where the shear stress vanishes. Integrating the profile gives discharge per unit width.
The cube of the gap arises because widening the channel increases both conducting area and the speed at a given pressure gradient. A moving wall adds a linear shear-driven profile through the boundary condition because the governing equation is linear.
Open full-size diagram
Derivation and applications
Quantify the effect of wall slip on laminar pipe resistance
A pressure-flow calibration of a small tube can reveal a change in the assumed wall condition. Consider steady, fully developed, axisymmetric flow of a Newtonian liquid of viscosity \(\mu\) in a round tube of radius \(R\). Take the pressure gradient magnitude \(G=-dp/dz>0\) and neglect body forces along the tube. Balance pressure force against viscous drag on a coaxial fluid cylinder of radius \(r\). Positive axial speed decreases approaching the wall.
Allow a Navier slip length \(b\geq0\) at the stationary wall: the wall speed extrapolates to zero a distance \(b\) beyond it in a local linear approximation. This gives
Integrating the shear rate from the wall into the flow adds a uniform velocity offset to the usual parabola.
Integrate the velocity over annuli to turn a local change of boundary condition into a measurable discharge. The contribution from the offset is proportional to the full area because the velocity addition is constant over the cross-section.
The shear stress needed to balance a fixed pressure gradient is unchanged. Effective slip lowers the required pressure gradient for a fixed flow. When \(b/R\) is small the fractional change is proportional to \(b/R\), making small tubes more sensitive at a given slip length.
Worked example
Calculate the extra discharge of a coated tube
Take \(R=100\) µm, \(b=5.00\) µm, \(\mu=1.00\) mPa s and \(G=10.0\) kPa/m. The no-slip flow is \(\pi(10^4)(10^{-4})^4/(8\times10^{-3})=0.393\) µL/s. Slip increases it by \(4b/R=0.200\), yielding 0.471 µL/s. The predicted wall speed \(GbR/(2\mu)=2.50\) mm/s could be examined by a near-wall tracer.
Change the inputs and inspect this calculation below
Second application
Infer a slip length from pressure reduction
A different tube of radius 40.0 µm requires only 80.0 percent of the reference no-slip pressure drop to sustain the same flow. Equal flow implies \(1+4b/R=1/0.800=1.25\), giving \(b=2.50\) µm. A radius calibration error can mimic this signal because the no-slip flow varies as \(R^4\). Independent bore measurements are therefore especially informative in this inverse experiment.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Transport momentum between neighbouring layers
Push two parallel plates past one another with liquid in the gap. Even at constant velocity the moving plate requires force. In a Newtonian fluid the tangential shear stress on a plane parallel to the motion is \(\tau_{xy}=\mu\,du/dy\). Dynamic viscosity \(\mu\) has units Pa·s. Divide it by density to obtain kinematic viscosity \(\nu\), an indicator of how rapidly momentum spreads through the fluid. Viscous resistance depends on a velocity gradient; uniform translation of the entire fluid would not create such stress.
Take two long horizontal plates separated by \(H\). Far from inlet and side walls assume constant density, constant viscosity and steady fully developed laminar motion \(u=u(y)\). The lower plate is fixed and the upper moves at speed \(U\). Represent the constant driving pressure gradient by \(G=-dp/dx\), positive for pressure falling downstream. A differential slab balances the downstream pressure force with the change in shear, giving \(0=G+d\tau_{xy}/dy=G+\mu u''\).
Impose the two wall velocities
The first integration gives
Integrating again and imposing no slip \(u(0)=0,\ u(H)=U\) determines the constants. The result is the sum of a straight wall-driven profile and a parabolic pressure-driven one:
Superposition here follows because the reduced equation and boundary conditions are linear in these inputs. It is not a universal property of the full nonlinear fluid equations. A negative \(G\) represents an adverse pressure rise and can produce a reverse-flow layer close to the stationary wall even when the moving wall drags fluid forward elsewhere.

Predict the pressure a moving surface can hold
An oil film has \(\mu=0.050\) Pa·s, \(H=1.0\) mm and \(U=0.20\) m/s. The wall-driven flux per unit width is \(UH/2=1.0\times10^{-4}\) m²/s. An adverse pressure gradient sufficient to reduce net flux to zero must satisfy \(G=-6\mu U/H^2=-60\,000\) Pa/m. Over 50 mm, pressure rises by 3.0 kPa. Zero net transport does not make the oil stationary.
Set \(s=y/H\) and insert the zero-flux gradient. The velocity is \(u/U=3s^2-2s\), which changes sign at \(s=2/3\) inside the film. The velocity gradient at the upper moving wall is \(4U/H=800\,\mathrm{s^{-1}}\), so the wall supplies shear of magnitude 40 Pa. Even though the pressure-driven and wall-driven volume rates cancel, the moving surface still performs work, dissipated through the internal shear field.
Connect a local solution to a network
In a horizontal circular tube with fixed wall, axisymmetry changes the area that carries shear. Balancing forces on a cylinder of radius \(r\) gives
Integrating the velocity gradient with no slip yields
Thus a straight developed pipe behaves as a hydraulic resistance \(8\mu L/(\pi R^4)\) in Pa·s/m³. Series resistances carry the same \(Q\) and their pressure drops add. Parallel branches share pressure drop and their flows add. The analogy requires consistent units and a laminar regime; short entrance sections and strongly accelerating junctions may add losses outside the fully developed solution.
Express pipe resistance as a friction factor
For a circular pipe of diameter \(D=2R\), the developed laminar solution gives
Define the Darcy friction factor by \(\Delta p=f_D(L/D)\rho\bar u^2/2\). Equating these expressions produces \(f_D=64/\mathrm{Re}_D\). For 2 m of 10 mm pipe with mean speed 0.10 m/s, water viscosity 0.001 Pa s and density 1000 kg/m³, the Reynolds number is 1000 and the pressure drop is 64 Pa. A friction factor listed in the Fanning convention is one quarter of the Darcy value, so identify the convention before substituting a tabulated number into a loss calculation.
Derive the profile of a shear-thinning liquid in a pipe
A Newtonian viscosity inferred in one duct may give poor predictions for a suspension or polymer solution at another rate. In a simple power-law model the shear stress magnitude is \(\tau=K|\dot\gamma|^n\), with consistency \(K\) in Pa sⁿ and index \(n\). A liquid with \(n<1\) has apparent viscosity decreasing with shear rate. Assume this law is supported over the shear range being sampled, flow is steady, axisymmetric, laminar and fully developed, and the circular pipe has no wall slip. The axial force balance is independent of rheology: at radius \(r\), \(\tau=Gr/2\) for driving gradient \(G=-dp/dx>0\).
Since the positive downstream velocity decreases towards the wall, write \(-du/dr=(Gr/2K)^{1/n}\). Integrate from radius \(r\) to the stationary wall at \(R\), then integrate the result over the circular cross-section to obtain
Setting \(n=1,\ K=\mu\) gives the parabolic profile and \(Q=\pi GR^4/(8\mu)\). For \(n<1\) the velocity is flatter towards the centre and the relationship between pressure gradient and flow rate is nonlinear. The ideal power law can imply unrealistic apparent viscosity near zero shear at the axis; a fitted model with finite limiting viscosities is preferable when measurements resolve those regimes.
Infer a pressure demand from wall shear
A model resin follows \(n=0.50,\ K=0.80\,\mathrm{Pa\,s^{0.5}}\) in the operating range. A 2.0 m pipe of radius 5.0 mm experiences a pressure drop of 8.0 kPa, giving \(G=4000\,\mathrm{Pa/m}\) and wall shear \(\tau_w=GR/2=10.0\,\mathrm{Pa}\). The wall shear rate is
Writing the mean speed in terms of this wall value gives
The corresponding flow is \(\pi(0.005)^2(0.15625)=1.227\times10^{-5}\,\mathrm{m^3/s}\), about 0.736 L/min.
To double flow in this same pipe, the power-law relation requires the gradient to rise by \(2^n=\sqrt2\). The new pressure drop is 11.3 kPa, and wall shear rate doubles to 312.5 s⁻¹. A linear resistance model extrapolated from the original measurement would predict 16 kPa. Conversely at fixed gradient a 10% radius increase multiplies rate by \(1.1^{3+1/n}=1.61\), a stronger dependence than the Newtonian fourth power. Verify the resulting shear rate still falls in the tested rheological range, and check entrance length and temperature. Temperature changes produced by viscous dissipation can otherwise mimic a shear-dependent viscosity.
Two well-spaced steady pressure tests can independently infer the unknown exponent. At fixed pipe geometry,
If pressure drop rises from 8.0 to 12.0 kPa while flow rises from 0.736 to 1.66 L/min, the log slope is \(\ln(1.66/0.736)/\ln(12/8)\simeq2.00\), giving \(n\simeq0.50\). Repeating the higher-pressure point after cooling checks whether heating caused hysteresis between runs. Using an inlet pressure transducer alone would also include a changing downstream pressure; both end pressures or a differential gauge are needed to identify the flow law from this experiment.
The pressure taps should bracket the same developed length at every setting because entrance losses may change differently with flow.
How does a local pressure gradient accelerate a fluid particle?
A duct solution generally begins by cancelling terms in the momentum balance. To decide which terms can be cancelled, follow a small volume of fluid. Its acceleration includes the change in the velocity at its present location and the change as it moves into a different part of the velocity field. Applying the chain rule along its trajectory gives
Consider the two faces normal to the first coordinate axis. Their net surface force per unit volume in direction \(i\) approaches \(\partial_x\sigma_{ix}\) as the face separation tends to zero. Summing the three face pairs and adding weight gives
For an incompressible Newtonian liquid of constant viscosity \(\mu\), insert \(\sigma_{ij}=-p\delta_{ij}+\mu(\partial_j u_i+\partial_i u_j)\). The cross derivative sums to \(\partial_i(\nabla\cdot\mathbf u)=0\). The remaining terms are the local equations
Take a horizontal slice through an ideal planar stagnation region, away from confining walls. The steady field \(u=ax,\ v=-ay\) satisfies continuity. Every velocity component is linear, so its Laplacian vanishes. Nevertheless the material acceleration is \((a^2x,a^2y)\). Integrating the two horizontal gradients gives
where \(p_0\) is the stagnation-point pressure at this elevation. For water at \(1000\,\mathrm{kg\,m^{-3}}\), \(a=4\,\mathrm{s^{-1}}\) and \(y=0.10\,\mathrm m,\ x=0\), pressure is 80 Pa below \(p_0\). Fluid entering along positive \(y\) moves towards the origin but accelerates in positive \(y\): it slows as pressure rises. At the stagnation point itself both velocity and acceleration vanish. Specifying \(p_0\) fixes the pressure datum. The velocity gradients determine the spatial change.
Interactive calculation · Change the inputs of this example
Change the parameters of this reference plot and compare its limiting cases. The fixed illustration remains beside the derivation; the adjustable calculation exposes the same dependence on geometry, material properties or loading.
Practise on sheet 3 · Which pressure difference establishes an accelerating uniform stream?. Further reading · MIT · 1.060 Engineering Mechanics II · Lectures 35–36, Differential Analysis of Fluid Flows: The Navier–Stokes Equation.
Study the full derivation
Why shear disperses a tracer faster than molecular diffusion · Momentum, motion and transport in fluids
A short dye pulse in a straight tube first stretches into a filament and much later resembles a broadened one-dimensional cloud. Derive the long-time Taylor–Aris coefficient, predict the width of a measured pulse and identify the mixing time needed before fitting the familiar one-dimensional approximation.