Fundamentals / Mechanical engineering / Fluid mechanics

Dynamic similarity, boundary layers and model tests

Choose dimensionless groups for a fluid experiment and determine which full-scale predictions a scale model can support.

From first principles

Read similarity conditions from the nondimensional momentum balance

Two geometrically similar channels can behave differently when inertia, viscosity and gravity contribute in different proportions. Use incompressible Newtonian flow with density \(\rho\), kinematic viscosity \(\nu\) and constant gravitational acceleration \(\mathbf g\). Choose length \(L\), speed \(U\), elapsed time \(L/U\) and pressure scale \(\rho U^2\). The underlying balance is force per unit mass equals acceleration.

\[\partial_t\mathbf u+\mathbf u\cdot\nabla\mathbf u=-\rho^{-1}\nabla p+\nu\nabla^2\mathbf u+\mathbf g .\]

Insert \(\mathbf u=U\mathbf u^*\), \(\mathbf x=L\mathbf x^*\) and the other scales. Divide through by \(U^2/L\). The viscosity and gravity terms acquire coefficients that compare their acceleration scales with inertia.

\[\partial_{t^*}\mathbf u^*+\mathbf u^*\cdot\nabla^*\mathbf u^*=-\nabla^*p^*+\frac1{Re}\nabla^{*2}\mathbf u^*+\frac1{Fr^2}\mathbf e_g,\]
\[Re=\frac{UL}{\nu},\]
\[Fr=\frac U{\sqrt{gL}} .\]

Here \(\mathbf e_g\) points downwards. Matching the relevant coefficients and dimensionless initial and boundary conditions gives the same nondimensional problem. Choosing what to match therefore depends on which physical effects matter for the measured observable.

Background · Reynolds number
\[\mathrm{Re}=\rho UL/\mu\]

Choose speed and length scales appropriate to the geometry. Matching this ratio compares inertial and viscous terms under the stated nondimensionalisation.

Derivation and applications

Scale a rising interface with Reynolds and Froude numbers

A free-surface model can match gravitational wave motion and still misrepresent viscous drag. Consider two geometrically similar open-channel experiments with characteristic lengths \(L_m,L_p\), speeds \(U_m,U_p\), gravitational accelerations \(g_m,g_p\) and kinematic viscosities \(\nu_m,\nu_p\). Ignore surface tension only when the Bond number is sufficiently large in both channels. Compare the inertial acceleration \(U^2/L\) with gravity and viscous acceleration \(\nu U/L^2\). Their ratios define

\[Fr=\frac{U}{\sqrt{gL}},\]
\[Re=\frac{UL}{\nu}.\]

Let \(\lambda=L_m/L_p\) be the model-to-prototype length ratio. Froude similarity fixes the velocity ratio because the shape and timing of long free-surface disturbances depend on the competition with gravity. Substituting this speed into Reynolds similarity fixes the required viscosity ratio as a second independent condition.

\[\frac{U_m}{U_p}=\sqrt{\lambda\,\frac{g_m}{g_p}},\]
\[\frac{\nu_m}{\nu_p}=\lambda^{3/2}\sqrt{\frac{g_m}{g_p}}.\]

A travel time scales as length divided by velocity, and discharge scales as velocity times geometrically similar area. The matching free-surface kinematics therefore predict two distinct dimensional scale factors.

\[\frac{t_m}{t_p}=\sqrt{\lambda\,\frac{g_p}{g_m}},\]
\[\frac{Q_m}{Q_p}=\lambda^{5/2}\sqrt{\frac{g_m}{g_p}} .\]

When the same liquid and gravity are used, exact equality of both dimensionless numbers is possible only at full scale. If boundary-layer details matter in a smaller channel, the calculated Reynolds mismatch quantifies what a Froude-scaled measurement leaves unresolved.

Worked example

Interpret a one-to-nine water channel

At equal gravity, \(\lambda=1/9\) gives a speed ratio of \(1/3\). A model flow of 0.400 m/s corresponds to 1.20 m/s at full scale. A 2.00 s wave passage scales to 6.00 s. With the same water, \(Re_m/Re_p=\lambda^{3/2}=1/27\), so a prototype Reynolds number of 270,000 becomes 10,000. Matching model surface-wave timing alone gives no guarantee of the same wall-shear coefficient.

Change the inputs and inspect this calculation below

Second application

Choose the viscosity for simultaneous matching

In a separate equal-gravity test, \(\lambda=1/4\) and the prototype liquid has \(\nu_p=8.00\) mm²/s. Simultaneous similarity requires \(\nu_m=(1/4)^{3/2}(8.00)=1.00\) mm²/s. A prototype discharge of 64.0 L/s maps to \(64.0(1/4)^{5/2}=2.00\) L/s. This pair of viscosity and discharge targets specifies two independently measurable conditions for commissioning the model.

Interactive calculation · Change the inputs of this example

Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.

OneSimulation laboratory

Measure boundary-layer growth from a velocity profile

Start from this chapter. At fixed distance, the Reynolds number doubles when the stream speed doubles. Predict the change in the ratio of layer thickness to distance before reading the output.

Compare recorded OneSimulation runs on this page. To test your own inputs, download the notebook and model files and run the model in an activated OneSimulation environment.

The OneSimulation domain begins 0.2 m downstream of the leading edge. Use the row labelled \(x=0.50\) m, which already includes that offset. The baseline uses stream=1.0 m/s, density=1.0 kg/m³ and dynamic_viscosity=1.0e-4 Pa·s.

  1. Double stream to 2.0 m/s. Rebuild the model so the imposed inlet profile also changes. Expect a thickness near 25 mm and smaller \(c_f\), even though the dimensional wall stress increases.
  2. Restore stream=1.0 and double dynamic_viscosity to 2.0e-4 Pa·s. At unchanged density, expect a thickness near 50 mm and \(c_f\) near 0.0133. Compare the departures from the similarity approximation with the baseline.
Computed boundary layer at 0.50 m from the leading edge
Free stream and viscosityThickness (mm)Friction coefficient (×10⁻³)
1 m/s, 0.10 mPa·s35.849.188
2 m/s, 0.10 mPa·s25.196.559
1 m/s, 0.20 mPa·s51.0312.878
At the same downstream station, doubling the speed thins the layer from 35.84 to 25.19 mm. Doubling viscosity thickens it to 51.03 mm.
At the same downstream station, doubling the speed thins the layer from 35.84 to 25.19 mm. Doubling viscosity thickens it to 51.03 mm.

View the OneSimulation flat-plate model and its velocity profiles.

Download experiment files (ZIP) Extract the files together and open blasius_flat_plate.ipynb in a local OneSimulation environment.

Interactive reference for the OneSimulation laboratory

Reintegrate the Blasius similarity profile and vary its dimensional scales. Compare this laminar1D similarity reference with the spatial OneSimulation run.

Problem sheet 4 · Infer viscosity from the edge of a boundary layer

Read the model setup and preparatory problems

Compare competing mechanisms

A scale model can reproduce a shape exactly and still display a different flow pattern. A fast oil stream and a slow water stream may behave similarly if the relevant dimensionless groups match. To see which groups enter, choose a typical length \(L\), speed \(U\), time \(L/U\) and pressure change \(\rho U^2\) in the incompressible Newtonian momentum equation. Divide by the inertial scale \(\rho U^2/L\). The coefficient multiplying viscous diffusion becomes \(1/Re\), where \(Re=\rho UL/\mu\).

If gravity must be retained, its coefficient is \(1/Fr^2\), with \(Fr=U/\sqrt{gL}\). A free water surface makes this particularly important because gravity restores disturbances. For a fully submerged shape in a constant-density fluid, gravity can often be absorbed into hydrostatic pressure, leaving the Reynolds number dominant. Extra effects can introduce more groups, for example roughness divided by length or oscillation frequency times \(L/U\). Choose groups to match the phenomenon being measured.

Derive a near-wall length scale

Consider a smooth flat plate parallel to a uniform stream with a negligible pressure gradient. In a laminar boundary layer, momentum is advected downstream on a scale \(U^2/x\) and diffuses across the shear layer on a scale \(\nu U/\delta^2\). Balancing them gives \(\delta\sim\sqrt{\nu x/U}\). The ratio \(\delta/x\sim Re_x^{-1/2}\) may be small even though the tangential shear force from the layer matters to the machine. The similarity solution places the 99% speed level near \(5x/\sqrt{Re_x}\), and the local skin-friction coefficient \(\tau_w/(\rho U^2/2)\) near \(0.664/\sqrt{Re_x}\).

Doubling speed at a fixed station multiplies the local Reynolds number by two. The dimensionless friction coefficient falls by \(1/\sqrt2\), but dynamic pressure grows fourfold. The dimensional shear therefore rises by \(2^{3/2}\). This distinction matters when reading plots of nondimensional test results: a lower plotted coefficient can accompany a larger actual force.

Scale a submerged component

A streamlined full-size probe of length 0.60 m moves at 2.0 m/s in water with \(\nu=1.0\times10^{-6}\,\mathrm{m^2/s}\). A geometrically similar third-scale model in the same water needs 6.0 m/s for equal Reynolds number \(1.2\times10^6\). Assume matching surface finish in relative terms, sufficiently small blockage, the same flow regime and no free-surface effect. Then the dimensionless drag \(C_D=F_D/(\rho U^2A/2)\) should agree. Since the model’s reference area is one ninth and its speed squared is nine times as large, its drag is equal to the prototype drag in this example.

If only 2.0 m/s can be reached in the test tank, the model Reynolds number is one third of full size. An observed transition, separation point or drag coefficient may then shift. Document this mismatch rather than scaling the raw measured drag by area alone. Matching a single group does not fix every boundary condition, especially the upstream disturbance level that can trigger transition.

Scale a different experiment with the same geometry

For a one-ninth length model of a surface vessel, matching Froude number requires

\[U_m=U_p/3.\]

In the same water its Reynolds number relative to the prototype is

\[(1/3)(1/9)=1/27.\]

Exact Froude and Reynolds similarity cannot both hold at that length and speed with the same fluid. Gravity-wave resistance can be compared at matched Froude number, while viscous skin friction needs a separate correction. Report both dimensionless numbers with the measured force and its reference area. That allows a reader to distinguish the physical part of the scaling argument from assumptions used for extrapolation.

Recover a dimensional frequency from a model

Matching a dimensionless frequency can transfer an unsteady effect. For an oscillation of frequency \(f\) in a stream of speed \(U\) past a length \(L\), the Strouhal number is \(fL/U\). A 0.10 m model in a 3 m/s stream oscillating at 6 Hz gives 0.20. If relevant geometry and governing dimensionless parameters are matched, a 0.50 m prototype at 2 m/s would oscillate at \(0.20(2)/0.50=0.80\) Hz. Frequency alone cannot be rescaled by the geometric factor when the reference speeds differ.

Determine when surface tension prevents gravity-wave similarity

A reduced-scale flume can match gravity and inertia by matching Froude number. The air–water interface also has surface tension \(\sigma\). A disturbance with characteristic length \(L\) and speed \(U\) has inertial pressure scale \(\rho U^2\), gravity scale \(\rho gL\), and capillary pressure scale \(\sigma/L\). The ratios produce \(\mathrm{Fr}^2=U^2/(gL)\) and \(\mathrm{We}=\rho U^2L/\sigma\). Dividing the latter by the former gives the Bond number \(\mathrm{Bo}=\rho gL^2/\sigma\). Choosing model speed to match Froude number leaves Bond number determined by geometry and material properties. With the same liquid and gravity, reducing length by ten reduces Bond number by one hundred.

For a more precise test use the small-amplitude, inviscid deep-water dispersion relation \(\omega^2=gk+\sigma k^3/\rho\) for wave number \(k=2\pi/\lambda\). The gravity term arises from surface elevation, while the capillary pressure perturbation is proportional to surface curvature \(k^2\eta\). The ratio of capillary to gravity restoring contributions is \(\sigma k^2/(\rho g)\). Equal contributions occur at wavelength \(2\pi\sqrt{\sigma/(\rho g)}\). The appropriate length in this ratio is \(1/k\); omitting the \(2\pi\) when using wavelength changes the inferred correction substantially.

Check a wave-frequency prediction at two geometric scales

For water use \(\sigma=0.072\,\mathrm{N/m},\ \rho=1000\,\mathrm{kg/m^3}\) and \(g=9.81\,\mathrm{m/s^2}\). The crossover wavelength is

\[2\pi\sqrt{0.072/9810}=0.0170\,\mathrm m.\]

Consider a prototype wave of wavelength 0.40 m. Its wave number is 15.71 m⁻¹ and the capillary-to-gravity ratio is

\[0.072(15.71)^2/9810=0.00181.\]

Its frequency is approximately \(\sqrt{9.81(15.71)(1.00181)}/(2\pi)=1.98\,\mathrm{Hz}\), essentially the gravity prediction.

A geometrically similar one-tenth model uses wavelength 0.040 m, wave number 157.1 m⁻¹ and capillary-to-gravity ratio 0.181. Pure gravity scaling would predict frequency \(\sqrt{10}(1.98)=6.26\,\mathrm{Hz}\). Including capillarity gives \(\sqrt{9.81(157.1)(1.181)}/(2\pi)=6.79\,\mathrm{Hz}\), about 8.5% higher. A frequency discrepancy need not indicate a clock error or a viscosity error. The model has moved into a region where a restoring force previously negligible is perceptible. Deep water also requires \(kh\) large at both scales; shallow flume depth adds a separate \(\tanh(kh)\) factor. Enlarging the model or choosing a different measured observable may be preferable to enforcing incompatible similarity conditions.

A useful comparison can be made by timing wave packets as well as crests. The phase speed is

\[c_p=\omega/k.\]

The group speed of a narrow wave packet follows from differentiating the dispersion relation,

\[c_g=[g+3\sigma k^2/\rho]/(2\omega).\]

Their ratio is \([1+3B]/[2(1+B)]\), where \(B=\sigma k^2/(\rho g)\). In the prototype example it is 0.502, close to the deep-water gravity value of one half. In the short model it is 0.653. Thus scaling time to match one measured crest frequency still would not make packets travel relative to their crests in exactly the same way. A video showing both individual crest motion and arrival of a packet envelope provides experimental evidence for the altered mechanism.

Surface contamination is another experimental variable: an altered surface tension changes the capillary correction without changing either geometric length or gravity-wave Froude number.

Study the full derivation

Settling spheres, Stokes drag and a wall correction · Momentum, motion and transport in fluids

A falling-sphere viscometer infers viscosity from terminal speed. Derive the drag on a no-slip sphere, distinguish creeping flow from merely steady motion and use radius, vessel width and orientation checks to decide what the speed experiment actually measures.