Fundamentals / Physics / Waves and optics

Waves and optics · Advanced study

Read the connected derivations and worked problems in sequence, or open each chapter in its home course.

  1. A wave in space, matter and a guide

    Rebuild a propagating mode from the field equations. Track vector polarisation and flux through an interface, then separate material from geometric dispersion.

  2. What a detector samples

    Compare radiation, scattering and the measured diffraction pattern. Examine how aperture sampling, transfer calibration and finite coherence alter the observable.

  3. Mechanical and thermal effects of light

    Calculate how a beam can translate a bead, couple resonances or exchange energy with a moving boundary. Test each proposal against a measured signal.

A wave in space, matter and a guide

Rebuild a propagating mode from the field equations. Track vector polarisation and flux through an interface, then separate material from geometric dispersion.

  1. From a local field balance to travelling waves and standing modes
  2. What an analyser measures about polarisation and coherence
  3. Oblique interfaces and films whose reflections cancel
  4. Causal material response and the propagation of a finite pulse
  5. A guided mode, a cavity line and the energy they carry
  6. When a periodic dielectric has no propagating Bloch wave
  7. Why rotating a layered dielectric changes a capacitance measurement
  8. How a magnetic field rotates the polarisation of transmitted light

From a local field balance to travelling waves and standing modes

A voltage probe moving along a line finds regularly spaced zeros. A second probe at the same point measures a magnetic field even when the electric reading vanishes. Derive both readings from Maxwell’s equations, calculate the energy stored between the zeros, and decide what additional measurement would reveal the direction in which energy travels.

Specify a medium, a region and a sign convention

Take a homogeneous, isotropic, transparent medium at rest. In the frequency range of interest its permittivity \(\epsilon\) and permeability \(\mu\) are positive, real constants. Neglect free charge and current in the region where we will propagate a field. Sources can still exist outside the region and set its incident wave. The electric and magnetic fields are functions of position and time. Maxwell's equations impose two divergence conditions in addition to the two evolution equations. In particular, \(\nabla\cdot\mathbf E=0\) here because \(\epsilon\) is uniform. At a material interface the normal condition concerns \(\mathbf D\), so one must reconsider this simplification before using the same wave equation across a boundary.

Consider first a plane field depending only on z and t, with electric polarization along x and magnetic field along y. Using a right-handed coordinate system, the y component of the curl of the electric field is \(+\partial_z E_x\). The x component of the curl of the magnetic field is \(-\partial_z H_y\). Faraday's law and Ampère–Maxwell's law then give

\[\partial_z E_x=-\mu\,\partial_t H_y,\]
\[\partial_z H_y=-\epsilon\,\partial_t E_x.\]

Imagine a localized positive electric bump travelling to the right. At a point just ahead of its centre the field grows in time. The second equation therefore requires a negative magnetic-field slope there. This checks the relative signs before making a harmonic assumption. With this convention a positive \(E_xH_y\) describes energy flow towards increasing z.

Find what travels and what remains constrained

Differentiate the first curl equation with respect to z and substitute the second. Constant \(\epsilon,\mu\) allow derivatives to commute with the coefficients. The electric field obeys \(E_{zz}=\epsilon\mu E_{tt}\). The same procedure gives the magnetic wave equation. More generally, taking the curl of Faraday's law produces

\[\nabla(\nabla\cdot\mathbf E)-\nabla^2\mathbf E=-\mu\epsilon\mathbf E_{tt}.\]

The divergence term vanishes under the stated assumptions. A formal solution of three unrelated scalar wave equations can still violate the divergence or original curl conditions. These conditions connect the measurable polarizations and reduce the independent initial data.

\[v=(\epsilon\mu)^{-1/2},\]
\[Z=\sqrt{\mu/\epsilon},\]
\[\partial_t(E_x+ZH_y)+v\partial_z(E_x+ZH_y)=0 .\]

The corresponding combination with a minus sign travels to the left. To see the first equation, expand it and replace \(E_t=-H_z/\epsilon\), \(H_t=-E_z/\mu\). The coefficients cancel because \(vZ=1/\epsilon\) and \(Z/\mu=v\). Hence there exist arbitrary waveform functions F and G such that

\[E_x(z,t)=F(z-vt)+G(z+vt),\]
\[H_y(z,t)=[F(z-vt)-G(z+vt)]/Z.\]

The medium determines two different quantities. Delay measurements determine the product \(\epsilon\mu\); measuring electric-to-magnetic amplitude in a single travelling wave determines their ratio. Impedance has units volts per ampere. It relates fields in volts per metre and amperes per metre at one location. A port voltage divided by current additionally depends on how a particular line geometry integrates those fields over a cross-section.

If only the initial electric field \(E_x(z,0)\) is known, its decomposition into left- and right-moving components is ambiguous. A simultaneous magnetic measurement supplies the missing combination. For example, suppose a local measurement gives \(E_x=3.0\) V/m and \(H_y=4.0\) mA/m in a medium with \(Z=250\) Ω. There \(ZH_y=1.0\) V/m, so the right-moving field equals 2.0 V/m and the left-moving field equals 1.0 V/m. These numbers describe local instantaneous amplitudes. Separating time-averaged directional powers requires squared waveform records or a harmonic representation.

Recover the energy current and average it correctly

Multiply the first curl equation by H, the second by E, and add. The spatial terms form \(\partial_z(EH)\), while the time terms form minus the derivative of \(\epsilon E^2/2+\mu H^2/2\). Thus in the absence of work on current the field obeys a local conservation law. The two travelling pieces give an especially useful representation of both sides:

\[u={\epsilon E^2+\mu H^2\over2}=\epsilon(F^2+G^2),\]
\[S_z=EH={F^2-G^2\over Z},\]
\[u_t+\partial_zS_z=0.\]

The energy densities add while the currents subtract. A field carrying equal left- and right-going powers can have substantial stored energy and zero mean transport. A cancellation in E alone says little about stored energy because it often accompanies a maximum in H. For the two local amplitudes of the preceding example the instantaneous net flux is

\[(4-1)/250=0.012\,\mathrm{W/m^2}.\]

Multiplying the original readings gives \(3.0\times0.004=0.012\) W/m², an independent check.

For harmonic calculations use real physical fields equal to \(\operatorname{Re}[\widetilde{\mathbf E} e^{-i\omega t}]\), so the phasors denote peak amplitudes. A product of real sinusoids averages to one half the real part of one phasor times the conjugate of the other. Therefore \(\langle\mathbf S\rangle=\operatorname{Re}(\widetilde{\mathbf E}\times\widetilde{\mathbf H}^{*})/2\). A single forward sinusoid with electric peak 6.0 V/m in vacuum carries \(36/(2Z_0)=0.0478\) W/m², using \(Z_0=376.73\) Ω. If an instrument already reports RMS electric amplitude, the factor of one half is absorbed in that reading. Mistaking an RMS calibration for a peak calibration changes an inferred power by a factor of two.

Enforce a conductor condition on the two waves

Place a perfect conducting plane at z=0 and illuminate it from negative z. The tangential electric field must vanish at the surface at all times. For peak incident phasor \(E_0 e^{ikz}\), with \(k=\omega/v\), the reflected field must be \(-E_0e^{-ikz}\); the accompanying magnetic fields add at the surface. Choosing real \(E_0\), the total phasors are

\[\widetilde E_x=2iE_0\sin(kz),\]
\[\widetilde H_y={2E_0\over Z}\cos(kz).\]

Electric nodes are separated by \(\pi/k=\lambda/2\). The magnetic antinodes sit at those same locations. At a fixed interior point the two fields are a quarter cycle out of phase. Their mean product is zero but their instantaneous product alternates sign. Examine a quarter wavelength of the standing wave: energy crossing an internal plane feeds local changes between electric and magnetic storage, while the conductor absorbs no net power in the idealization.

In a nonmagnetic dielectric with \(\epsilon_r=4\), the phase speed is \(c/2\) and \(Z=Z_0/2\). At 500 MHz the wavelength is 0.2998 m and successive electric zeros lie about 150 mm apart. A 4 V/m incident peak gives an 8 V/m electric antinode and magnetic amplitude \(8/(188.4)=0.0425\) A/m at the conductor. A tiny electric probe positioned at the conductor would read essentially zero. A loop sensing magnetic flux can respond strongly there. The response of a real loop also depends on its orientation, area and the frequency-dependent conversion of flux to voltage.

Build a complete family between two walls

Put conductors at \(z=0,L\). Tangential E now vanishes at both endpoints. Try a separated solution \(E=X(z)T(t)\). Dividing the wave equation by XT gives \(X''/X=T''/(v^2T)=-k^2\) for an oscillatory solution. The first condition eliminates the cosine term in X. The second enforces \(k_n=n\pi/L\), \(n=1,2,\ldots\). Frequencies are

\[\omega_n=vk_n.\]

There is no nonzero constant tangential electric mode consistent with two zero boundary values. A static magnetic bias can be independently specified through initial flux; it does not belong to this oscillatory electric-mode series.

\[E(z,t)=\sum_{n=1}^{\infty}\sin(k_nz)[A_n\cos(\omega_nt)+B_n\sin(\omega_nt)] .\]

To find coefficients, multiply the initial field by \(\sin(k_mz)\) and integrate over the interval. Product-to-sum identities give zero for \(n\ne m\), and \(L/2\) for \(n=m\). Thus \(A_m=(2/L)\int_0^L E(z,0)\sin(k_mz)\,dz\). Applying the same projection to the initial time derivative gives

\[B_m=(2/(\omega_m L))\int_0^L E_t(z,0)\sin(k_mz)\,dz.\]

The curl equation supplies \(E_t\) from the spatial derivative of the initial H field. These formulas convert measured initial data into mode coordinates. A point reading alone supplies one linear combination of all coordinates.

One can also derive orthogonality without already knowing the sines. Multiply the eigen-equations for \(X_n\) and \(X_m\) by the opposite functions, subtract, and integrate. The boundary term \([X'_n X_m-X'_m X_n]_0^L\) is zero, so

\[(k_n^2-k_m^2)\int X_nX_m dz=0.\]

Other homogeneous boundary conditions can preserve this cancellation. Spatially varying material parameters generally change the weight in an orthogonality relation. Knowing the inner product matters when estimating an amplitude from measured fields in unlike dielectrics.

Predict which modes a localized preparation actually excites

Imagine an idealized initial tangential electric field with a symmetric top-hat amplitude \(E_a\) on \(L/3<z<2L/3\), zero elsewhere, and zero initial H. Then \(B_n=0\) and integration gives

\[A_n={2E_a\over n\pi}\,[\cos(n\pi/3)-\cos(2n\pi/3)] .\]

Symmetry around the middle eliminates even n because their sine eigenfunctions change sign about that point. For \(n=1,3,5\) the coefficients are \(2E_a/\pi,\ -4E_a/(3\pi),\ 2E_a/(5\pi)\), respectively. Negative \(A_3\) is a relative phase; its contribution to stored energy is positive. Orthogonality gives initial total electric energy per transverse area \(\epsilon L\sum A_n^2/4=\epsilon L E_a^2/6\). The first mode carries \(6/\pi^2\approx60.8\%\) of that total, while the third carries \(8/(3\pi^2)\approx27.0\%\). A three-mode truncation reproduces a large share of the energy and still rounds the sharp initial edges. Measured peak error and integrated energy error answer different questions about that approximation.

Take \(L=0.60\) m filled with the dielectric above. The first frequency is about 124.9 MHz. A receiver at midspan sees modes 1 and 3 with opposite spatial signs. A second receiver at \(L/3\) has a node of mode 3 and will miss it. Detecting only one large peak after changing receiver position is therefore insufficient evidence that the source was single mode. Predict the source overlap, propagation loss and receiving overlap separately before interpreting a spectrum.

Use an open wave measurement as an independent power check

The linked calculation treats a propagating field and derives an energy-flux observable. Read its amplitude convention and the material properties beside the inputs. Predict which quantity changes quadratically when you vary only field amplitude. If a lab measures a total power, convert the calculated flux using the illuminated area and the angle between the flux vector and the detector normal. For a plane wave in a uniform medium, changing area at fixed field changes total intercepted power without changing any local field. In a narrow cavity beam the local field itself varies across the aperture, so the area product must be replaced by a surface integral.

Compare fields, energy density and transported power in the chapter experiment

An investigation of wave speed on a space–time mesh

A pulse simulation offers a second way to test the continuum mode calculation. Instead of assuming a single-frequency source, initialise a packet in a uniform one-dimensional region and record the times when it crosses two stations. First predict how the numerical method can change this transit measurement. A code that respects the differential equations as its mesh tends to zero can have a noticeably incorrect propagation speed at a finite resolution.

Work with an electric component \(E_y\) on integer mesh points and a magnetic component \(H_z\) on the intervening half points. Store the magnetic component half a time step later than the electric component. Faraday's law compares the electric field on the two ends of one spatial interval. Ampère's law compares the two magnetic components bounding the electric location. With \(d=\Delta x\) and \(s=\Delta t\), their integral balances become

\[H_{j+1/2}^{n+1/2}=H_{j+1/2}^{n-1/2}-\frac{s}{\mu d}(E_{j+1}^n-E_j^n),\]
\[E_j^{n+1}=E_j^n-\frac{s}{\epsilon d}(H_{j+1/2}^{n+1/2}-H_{j-1/2}^{n+1/2}).\]

For a forward wave the indicated components have the same sign. A change in either sign convention requires changing both updates consistently. Placing the variables on staggered meshes also matters when sampling power. A product of an electric field and the nearest stored magnetic number is not automatically their product at a common event. Interpolate both in time and space for a quantitative flux comparison, or use a discrete energy identity appropriate to the scheme.

Eliminate the magnetic values by taking a second time difference of the electric update. The resulting equation equates the centred second time difference to \(C^2\) times the centred second space difference, where \(C=us/d\) and \(u=1/\sqrt{\mu\epsilon}\). For the discrete mode \(E_j^n=E_0e^{i(kjd-\omega ns)}\), the difference of the forward and backward phases becomes a sine. Take the branch connected to the continuum wave at small positive \(k\).

\[\sin(\omega s/2)=C\sin(kd/2),\]
\[\frac{v_{\rm phase}}u=\frac{\arcsin[C\sin(kd/2)]}{Ckd/2},\]
\[\frac{v_{\rm group}}u=\frac{\cos(kd/2)}{\sqrt{1-C^2\sin^2(kd/2)}} .\]

The group speed follows by differentiating the frequency with respect to wavenumber before choosing a particular packet. The right-hand side of the sine equation must remain within the range of real sines for every mesh mode. This gives \(C\leq1\) in this one-dimensional uniform problem. If a short-wavelength mode violates the condition, a growing discrete solution accompanies the decaying one. A seemingly smooth start may seed very little of either, but roundoff or a sharp boundary can excite the growing solution. A stable choice still permits frequency-dependent speed.

For ten samples per wavelength and \(C=0.50\), the phase and group speed ratios are approximately 0.988 and 0.963. Over twenty wavelengths a phase crest is about a quarter of a cycle late, and the envelope peak has an even larger relative lag. With twenty samples per wavelength the errors shrink roughly fourfold. Reducing only the time step at fixed space resolution need not improve the result: the spatial difference retains its own dispersion error, and the temporal error can partially compensate it. At \(C=1\) in this idealised one-dimensional uniform case the phase relation on the resolved branch is exact. A slanted multidimensional wave, a discontinuous medium or a different mesh does not inherit that special cancellation.

A worked time-of-flight measurement with uncertainty

To construct an initial forward pulse, give the electric field a broad Gaussian envelope multiplying its carrier and assign the associated magnetic field \(H=E/Z\) at its proper staggered locations and times. Setting the magnetic field to zero instead launches a superposition of left- and right-moving packets of comparable amplitude. A reflecting wall can return one packet through the sensor after the other. Before fitting a speed, identify a time window that excludes every return from the domain boundaries. Check this by increasing the distance to the nearest wall without changing either station.

Suppose the expected continuum transit between stations is 100.0 ns, each threshold crossing is timed to 0.3 ns and the station spacing is known to 0.2 percent. Independent timing errors contribute \(\sqrt2(0.3)/100=0.00424\) relative uncertainty to the difference. Combined in quadrature with the length uncertainty this gives 0.47 percent. The roughly 3.7 percent group-speed bias at ten points per wavelength should be distinguishable, while the smaller phase error calls for careful identification of the same crest at both stations. A common clock offset cancels from the difference, whereas a common timebase scale error does not.

A threshold on the leading edge tracks a changing fraction of peak amplitude if the model disperses the pulse. Use a complex narrow-band signal and fit the slope of the unwrapped phase difference against frequency as a second estimate of group delay. For a single frequency only the phase modulo \(2\pi\) is observed. An apparent speed that jumps as the station separation changes by a small fraction of a wavelength can be an unwrapping error, even though the electric time series looks smooth. Begin with stations close enough to choose a branch, then follow the branch as their separation increases.

An additional stringent check uses two packets with different carrier wavelengths but equal initial envelope width in space. If the narrow-band condition holds for both, their group delays should match the two predictions of the mesh dispersion relation. Measured delays that approach the same continuum value with refinement while their difference obeys the predicted wavelength dependence support the diagnosis of numerical dispersion. A nonvanishing delay difference in the refined limit calls for revisiting the assumed physical material law, the timing observable or the boundaries. A single apparent agreement at one wavelength cannot distinguish these possibilities.

Separate flux from standing-wave energy

Change the balance of waves travelling in opposite directions. Identify a point where the instantaneous field is large while net power transfer is small.

Worked inverse problem · estimate the energy of an invisible mode

A conducting one-dimensional cavity contains its first and third electric standing modes. At a common electric maximum in time let \(E(x)=a\sin(\pi x/L)+b\sin(3\pi x/L)\). A small signed probe at \(L/2\) reads 2.0 V/m, and a probe at \(L/6\) reads 4.0 V/m. Determine the two amplitudes and the fraction of energy in the third mode. Compare this result with what could be concluded from two intensity probes alone.

Solve the signed and unsigned versions

The centre gives \(a-b=2.0\). The second station gives \(a/2+b=4.0\). Summing the equations yields \(a=4.0\) V/m and hence \(b=2.0\) V/m. At this instant the compatible free modes have zero magnetic amplitude. Spatial orthogonality makes integrated electric energy proportional to \(a^2+b^2\), even though there are local interference terms. The third mode therefore carries 20 percent of total energy. This fraction stays fixed during free evolution in an ideal lossless cavity. The instantaneous electric share of each mode alone oscillates in time.

Two intensity probes would give only magnitudes of the two readings. Choose the centre reading positive by a global sign convention. The second could then be \(-4.0\) instead. Solving \(a-b=2.0\), \(a/2+b=-4.0\) gives \(a=-4/3\) and \(b=-10/3\) V/m, for a third-mode fraction \(100/116=0.862\). Both field preparations produce the same two intensities. A third carefully chosen position, a phase-sensitive receiver or a frequency-resolved trace distinguishes them. A probe at a location that simply duplicates either existing linear combination adds precision but cannot supply the missing sign.

An eigenmode decomposition is therefore both a prediction tool and an experimental design tool. Before choosing sensors, form the matrix of sampled mode shapes and check whether its columns remain distinguishable within noise. If two stations approach a shared node, the inferred coefficients can grow unstable while the predicted signal at those stations remains an excellent fit. A held-out measurement away from the common node exposes the ambiguity.

Why a sharp preparation resists uniform modal convergence

A rectangular initial displacement has a jump. Any finite sum of the smooth sine modes is continuous and therefore cannot converge uniformly to a function with different one-sided limits. Near the edge a partial sum oscillates. Increasing the cutoff makes the oscillatory region narrower, but its largest overshoot does not tend to zero relative to the jump. Pointwise comparisons a fixed positive distance from the jump and spatially integrated energy tell a different story from the maximum error.

This is physically relevant to preparing an electromagnetic cavity. No source creates a perfectly discontinuous field with unbounded bandwidth. Replace the top hat by its convolution with a smooth narrow preparation profile. The modal coefficients then acquire the Fourier transform of that profile as a high-frequency envelope. Doubling the number of retained modes beyond the preparation bandwidth should change both the integrated energy and the measured field little. A finite-width detector performs its own additional averaging, even when the preparation is sharp.

An informative validation uses two limits in a stated order. Fix the physical source and detector widths while increasing the number of modes until the detector prediction converges. Then vary the physical widths to investigate the sharp-edge limit. Shrinking the model widths each time the numerical resolution increases changes the problem being solved and may keep the apparent peak error from decreasing.

Tutorial · reconstruct a partial reflection from three observations

A coherent line scan in a nonmagnetic medium of known \(Z=200\) Ω finds successive electric maxima 80 mm apart at 1.0 GHz. Maximum and minimum peak electric amplitudes are 5.0 and 1.0 V/m. Determine phase speed, incident and reflected peak fields and mean net flux. Explain exactly what fixes the phase of the reflection coefficient and what remains ambiguous in these observations.

Derive the two directional amplitudes

For nonnegative amplitude magnitudes \(a,b\), the maxima and minima of the sum of two opposite travelling waves are \(a+b\) and \(|a-b|\). If the source is known to lie to the left and net transport is rightward, \(a>b\), so \(a=3.0,\ b=2.0\) V/m. Wavelength is twice the 80 mm maximum spacing and \(v=f\lambda=1.60\times10^8\) m/s. The reflection magnitude is \(2/3\), and the average net flux is

\[(9-4)/(2\cdot200)=0.0125\,\mathrm{W/m^2}.\]

A measurement of node spacing constrains the relative phase change over distance. Determining reflection phase at a named load additionally requires the position of a maximum or minimum relative to that reference plane. Without an independent source direction, swapping a and b produces the same electric envelope but reverses the net flux.

Tutorial · test whether a receiver can reconstruct two stored modes

At an instant when both cosine time factors are one, only the first and third electric modes contribute. At midspan the field is 3.0 V/m; at one third span it is 1.732 V/m. Determine \(A_1,A_3\) and the stored electric energy per unit area for \(L=0.60\) m,

\[\epsilon=4\epsilon_0.\]

Would a second sensor at two thirds span provide independent information if it replaced the midspan sensor?

Solve the observation system and identify its rank

At one third span \(\sin(\pi/3)=\sqrt3/2\) and \(\sin\pi=0\), so \(A_1\simeq2.00\) V/m. At midspan the combination is \(A_1-A_3=3.0\), hence \(A_3=-1.0\) V/m. The energy per area is \(\epsilon L(4+1)/4=2.66\times10^{-11}\) J/m². At two thirds both sinusoids have the same values as at one third for these odd modes: the first is \(\sqrt3/2\) and the third is zero. Those two rows would be identical. More digits in either measurement cannot resolve \(A_3\) from that pair. An offset from a node helps, but near a node a small measured voltage also amplifies calibration noise in the reconstruction.

David Staelin, MIT 6.013 · electromagnetic waves, power and Maxwell boundary conditions

What an analyser measures about polarisation and coherence

Two red beams produce the same reading through every rotating linear polarizer. One might be circularly polarized and the other an incoherent mixture. Build the measurements that distinguish them, derive the visibility of their interference fringes, and decide which information is lost on a slow detector.

Begin with the measured quantity and the averaging time

Fix a beam travelling in positive z and choose perpendicular laboratory axes x and y in the detection plane. Represent a narrowband field by \(\operatorname{Re}[\mathbf e(t)e^{-i\omega_0 t}]\). The complex envelope \(\mathbf e=(e_x,e_y)\) varies slowly compared with an optical cycle. A photodiode collecting many cycles measures a time average of energy flux, possibly over many independent changes of the envelope. In a transparent isotropic medium a convenient intensity convention is \(I=\langle |e_x|^2+|e_y|^2\rangle/(2Z)\). All comparisons in this unit assume equal transmissive losses and detector responsivity unless a calibration factor is stated.

A deterministic monochromatic field has a Jones vector. Its overall complex phase disappears from all single-beam intensities, while a relative phase between components can change the polarization ellipse. For example, use the normalized vectors \((1,0),\ (1,1)/\sqrt2,\ (1,i)/\sqrt2\). The first is x-linear, the second linear at +45°, and the last circular. At a fixed point choose the time origin so the physical electric vector for the last case begins on the positive x axis and then moves towards positive y as t increases. This explicit convention avoids ambiguity in the words left and right circular, which depend on where an observer stands.

A fast field sampler would reconstruct both real components directly. Optical intensity measurements normally come with a response time much longer than a cycle. The data naturally contain squares and correlations of fields. A random global phase changing between shots destroys the inferred absolute phase but need not depolarize a single beam. If \(e_y=i e_x\) in every shot, their relative phase stays fixed however rapidly the common phase wanders. A detector can measure that relationship with suitable polarizing optics.

Derive a quadratic form for any analyser setting

An ideal analyser transmitting normalized Jones vector \(\mathbf a\) first projects the incident field to complex amplitude \(\mathbf a^\dagger\mathbf e\). Squaring and averaging gives a quadratic form in \(\mathbf a\). Define the coherency matrix in intensity units by \(J_{ij}=\langle e_i e_j^*\rangle/(2Z)\). It is Hermitian, its diagonal entries are nonnegative, and its trace is total intensity. For any vector b,

\[\mathbf b^\dagger J\mathbf b=\langle|\mathbf b^\dagger\mathbf e|^2\rangle/(2Z)\ge0.\]

This positivity will later provide an immediate check on measured data.

\[I_{\mathbf a}=\mathbf a^\dagger J\mathbf a,\]
\[S_0=J_{xx}+J_{yy},\]
\[S_1=J_{xx}-J_{yy},\]
\[S_2=2\Re J_{xy},\]
\[S_3=-2\Im J_{xy}.\]

With this sign convention the circular vector \((1,i)/\sqrt2\) has positive \(S_3\). Invert the four definitions to reconstruct \(J=\tfrac12\left(\begin{smallmatrix}S_0+S_1&S_2-iS_3\\S_2+iS_3&S_0-S_1\end{smallmatrix}\right)\). A linear polarizer with real \(\mathbf a=(\cos\alpha,\sin\alpha)\) gives

\[I(\alpha)=\tfrac12[S_0+S_1\cos(2\alpha)+S_2\sin(2\alpha)].\]

This follows by expanding the two squared direction cosines and the cross term. The imaginary part of the correlation drops out for every real analyser. Scanning a linear analyser with arbitrarily fine angular steps cannot supply that missing observable. Measuring the two circular analyser states supplies \(I_+-I_-=S_3\); their sum, like any pair of orthogonal ideal outputs, equals \(S_0\). In a dual-beam measurement it is useful to compare that sum with \(I_x+I_y\) as a consistency check on losses.

Build a circular analyser from a retarder

An ideal lossless plate with fast and slow axes x and y introduces a relative phase \(\delta\). Factoring out an unobservable common phase, its Jones matrix in those axes is \(D=\operatorname{diag}(1,e^{i\delta})\) for the chosen sign of retardance. If the axes are rotated by an angle \(\alpha\), express the incoming vector in the rotated basis, apply D, then transform back. With \(R(\alpha)\) the ordinary real two-dimensional rotation, the laboratory matrix is \(R(\alpha)D R(-\alpha)\). Reversing the sign of \(\delta\) interchanges retardation conventions, so calibrate a handedness label using a known input.

For a quarter-wave plate with \(\delta=\pi/2\) followed by a +45° linear polarizer, the transmitted amplitude is \((e_x+i e_y)/\sqrt2\). The analyzer equivalent to this sequence is the vector \((1,-i)/\sqrt2\). Hence it reads \(I_-\) in the preceding convention. Interchange the downstream polarizer between +45° and −45° to realize the two orthogonal circular measurements. For a half-wave plate, a linear input at angle \(\psi\) relative to its fast axis emerges linearly polarized at angle \(-\psi\) relative to that axis, modulo \(\pi\). Rotating a half-wave plate by 1° rotates the linear output by 2° when the incident direction is held fixed.

Suppose a plate designed at 600 nm has physical birefringence \(\Delta n=0.010\). If the relative phase magnitude is \(2\pi\Delta n\,d/\lambda_0\), a first-order quarter wave needs \(d=\lambda_0/(4\Delta n)=15\) μm. At 650 nm, holding \(\Delta n\) fixed, the same plate delivers \(0.923(\pi/2)\), about 83.1°. With a +45° linear input, equal component amplitudes are preserved but a residual \(S_2/S_0=\cos\delta\approx0.121\) remains. A linear analyser scan that varies slightly with angle can therefore reveal retardance error even when the output looks nearly circular.

Reconstruct the degree and axes of polarization

Hermitian J has real nonnegative eigenvalues. Calculating the trace and determinant yields eigenvalues \(\lambda_\pm=(S_0\pm s)/2\), where \(s=(S_1^2+S_2^2+S_3^2)^{1/2}\). The degree of polarization is \(P=s/S_0\) for positive intensity. Positivity requires \(P\le1\). A single deterministic Jones vector gives a rank-one outer product and P=1. A completely unpolarized field gives \(J=(S_0/2)I\) and P=0. An isotropic unpolarized contribution adds equally to both eigenvalues. The excess of the larger eigenvalue over the smaller gives the uniquely polarized contribution in this decomposition.

\[2\psi=\operatorname{atan2}(S_2,S_1),\]
\[\sin(2\chi)=S_3/s .\]

Here \(\psi\) is the ellipse orientation modulo \(\pi\); \(\chi\) is an ellipticity angle between \(-\pi/4\) and \(+\pi/4\). The ratio of minor to major field axes is \(|\tan\chi|\). At circular polarization the orientation is undefined, and near this limit even small noise on \(S_1,S_2\) can rotate a fitted orientation substantially. At P=0 neither angle describes a measurable polarized component.

Consider readings of 7 and 3 mW for horizontal/vertical, 6 and 4 mW for ±45°, and 8 and 2 mW for the positive/negative circular analysers. Every pair sums to 10 mW. The Stokes vector is \((10,4,2,6)\) mW, \(s=\sqrt{56}=7.48\) mW, \(P=0.748\). The polarized-component angle is \(13.28^\circ\), and \(\chi=\tfrac12\arcsin(6/\sqrt{56})=26.6^\circ\). A linear analyser alone would have suggested a modulation depth \(\sqrt{20}/10=0.447\). The recovered eigenvalues, about 8.74 and 1.26 mW, are the largest and smallest transmitted powers over all ideal elliptical analysers. The largest intensity available to a linear analyser is only \((10+\sqrt{20})/2=7.24\) mW.

Derive the two-arm visibility and its ambiguities

Now split a quasimonochromatic scalar field between two interferometer arms with delay \(\tau\) and relative phase \(\varphi\). At one output combine complex fields \(e_1(t)\) and \(e_2(t-\tau)e^{i\varphi}\), absorbing beam-splitter factors into arm intensities \(I_1,I_2\). Expanding the squared sum gives

\[I(\varphi)=I_1+I_2+2\sqrt{I_1I_2}\Re[\gamma_{12}(\tau)e^{i\varphi}],\]
\[\mathcal V={I_{\max}-I_{\min}\over I_{\max}+I_{\min}}={2\sqrt{I_1I_2}\over I_1+I_2}|\gamma_{12}(\tau)|.\]

Define \(\gamma_{12}=\langle e_1^*(t)e_2(t-\tau)\rangle/\sqrt{\langle|e_1|^2\rangle\langle|e_2|^2\rangle}\), provided both intensities are nonzero. Cauchy–Schwarz enforces \(|\gamma|\le1\). For vector beams with constant normalized polarizations \(\mathbf a_1,\mathbf a_2\), an additional overlap \(\mathbf a_1^\dagger\mathbf a_2\) appears. Orthogonal polarizations can erase fringes even when relative phase is perfectly stable. A common output analyser projects both beams into the same polarization and can restore modulation at a reduced transmitted flux.

An interferometer gives \(I_1=4.0\) mW, \(I_2=1.0\) mW and observed visibility 0.60 with matched polarization. The intensity imbalance alone limits visibility to \(2\sqrt4/5=0.80\). Thus \(|\gamma|=0.75\). If the polarizations are instead linear at 30° to each other, the polarization overlap is 0.866 and the inferred scalar degree of coherence is

\[0.60/(0.80\cdot0.866)=0.866.\]

Reporting visibility as a direct measure of source coherence requires both arm powers and polarization overlap. Detector backgrounds additionally increase the denominator without increasing fringe modulation.

Translate a spectrum into a coherence envelope

For a stationary scalar field, different frequency components of a long acquisition add in average intensity. A relative delay changes the phase of each by its own frequency times \(\tau\). Consequently the mutual coherence of two copies of the same field is proportional to the Fourier transform of the optical power spectrum. If the normalized spectrum is Gaussian in ordinary frequency, with centre \(\nu_0\) and standard deviation \(\sigma_\nu\), completing the square in the Gaussian Fourier integral gives

\[|\gamma(\tau)|=\exp(-2\pi^2\sigma_\nu^2\tau^2),\]
\[\tau_{1/e}={1\over\sqrt2\pi\sigma_\nu}.\]

The rapid carrier phase varies at \(\nu_0\), while finite bandwidth sets the envelope. For \(\sigma_\nu=1.0\) THz the amplitude coherence drops to \(1/e\) at 0.225 ps. This is 67.5 μm of vacuum optical path difference. In a Michelson geometry the corresponding mirror travel is half that, since light traverses the additional gap twice. An instrument quoting a coherence length should specify which envelope level, which bandwidth convention and which path geometry it uses. Replacing a standard deviation by a full width at half maximum without conversion changes the answer substantially.

Predict three analyser readings before changing the source

Use the polarimetry calculation with a polarized fraction below one. Set the ellipse orientation to 0°, choose positive ellipticity, and compute the horizontal, diagonal and circular contrasts using the definitions above. A change in polarized fraction scales the three contrast components together. Changing orientation alone rotates the linear contrasts through twice the physical angle while leaving the circular contrast fixed. A separate crystal model follows energy flow when two eigenpolarizations propagate in a birefringent plate. For comparison, separate the output phase retardance of a plate from any spatial displacement that could reduce the overlap of two exiting beams on an interferometer detector.

Change ellipticity and reconstruct an unknown polarization in the Stokes experiment

Compare eigenpolarizations and displacement in a crystal

An investigation with a photon-counting polarimeter

A polarimeter reports a count for each analyser, not an exact Stokes vector. A useful second reconstruction starts with a statistical model for those counts. Let all six exposures have the same duration and gain after calibration. For a pair of complementary analyser settings labelled \(+\) and \(-\), the mean counts at one exposure time are \(N(1+s)/2\) and \(N(1-s)/2\), with \(s=S_i/S_0\). Here \(N\) is the expected pair total after background removal. Independent Poisson counting models shot noise from a steady source. If the source changes between exposures this independence assumption no longer describes the common intensity drift.

Condition on the observed sum \(n=n_++n_-\). The number in the positive channel then has a binomial distribution with success probability \((1+s)/2\). The natural estimator and its conditional variance follow without assuming equal noise in bright and dark channels:

\[\widehat s=\frac{n_+-n_-}{n_++n_-},\]
\[\operatorname{var}(\widehat s\mid n)=\frac{1-s^2}{n}.\]

The uncertainty becomes small near a pure eigenpolarisation in the matching analyser, while a transverse component of the same beam has \(s=0\) and variance about \(1/n\). Exact intervals are preferable near the boundary, where a symmetric error bar would extend into unphysical values. Conditioning is appropriate for a single pair. If one uses the same intensity measurement to normalise several pairs, their reported components become correlated.

Consider the six counts \((800,200),(620,380),(550,450)\) in complementary linear-horizontal, diagonal and circular bases. Their normalised components are 0.60, 0.24 and 0.10. Raw degree of polarisation is

\[\sqrt{0.6^2+0.24^2+0.10^2}=0.654.\]

Individual shot-noise estimates are 0.025, 0.031 and 0.031. To first order, uncertainty in the degree is obtained by projecting the component variance along the measured unit vector. For independent pairs the result is approximately 0.026. Fitting an ellipse to this partially polarised beam recovers the polarised component's ellipse; the unpolarised intensity contributes to every positive and negative analyser reading.

For an unpolarised source, taking a square root of three squared noisy estimates always returns a nonnegative number. In fact the expected squared reported degree is approximately \(3/n\) when all pair totals equal \(n\). At \(n=1000\) the root-mean-square value is 0.055, even with a perfect instrument. A positive fitted degree around 0.04 in a single exposure therefore cannot establish weak polarisation. Repeat the acquisition at four times the counts. A statistical excess falls in scale by about two, whereas stable true components persist with their signs. A forced projection onto the physical Stokes sphere cannot remove calibration drift or substitute for this uncertainty calculation.

Which-path information encoded in a polarisation state

A balanced interferometer supplies a different quantitative probe. Suppose its path lengths are equal, the beam in arm one has unit horizontal polarisation \(\mathbf e_1\), and a rotator in arm two produces \(\mathbf e_2=\cos\alpha\,\mathbf e_1+\sin\alpha\,\mathbf e_y\). The detector receives equal-amplitude contributions with relative phase \(\delta\). Squaring the sum in the two output ports of an ideal lossless beamsplitter gives complementary fringes.

\[I_\pm=\frac{I_{\rm tot}}2(1\pm\cos\alpha\cos\delta).\]

For \(\alpha=60^\circ\), sweeping the phase from constructive to destructive moves one port between \(0.75I_{\rm tot}\) and \(0.25I_{\rm tot}\); the visibility is 0.50. Their sum should remain constant throughout the sweep. If both measured ports fade together, look for path loss, a changing source or detector gain. Polarisation distinguishability moves fringe energy between the two outputs in this ideal result. It does not remove energy from both.

At \(\alpha=90^\circ\), complete temporal coherence does not suffice for an unpolarised intensity detector to see fringes. The two field vectors are orthogonal and their scalar product vanishes. Insert an analyser at \(45^\circ\) in front of one detector. It projects both contributions onto the same unit vector with equal positive amplitude \(1/\sqrt2\), so the maximum visibility returns while the phase-averaged brightness of that port halves. An analyser at \(-45^\circ\) gives a fringe displaced by half a period. Summing those two orthogonal analyser intensities restores the original featureless signal. The recovered fringes do not require a change in either source clock or path length.

For unequal arm intensities and a time delay, the interference coefficient additionally contains \(2\sqrt{I_1I_2}/(I_1+I_2)\) and the magnitude of the normalised temporal coherence evaluated at that delay. This factorisation assumes the temporal waveform and polarisation can be separated in each arm. A broadband retarder with appreciable frequency-dependent axes couples the two. Then compute the spectral integral of the polarisation-resolved field products, preserving the complex phase at each frequency before integration. Multiplying three averaged magnitudes can give the wrong result even if every factor lies between zero and one.

A practical discrimination uses three sweeps at fixed geometry. First measure both single-arm intensities by blocking one arm at a time. Second sweep delay near zero with the analyser removed, and third repeat with the two orthogonal diagonal analysers. If the two diagonal traces regain equal but opposite fringes and sum to the original low-visibility result, distinguishability is a plausible explanation. If none shows variation after path intensities have been balanced, check whether the coherence envelope is narrower than the available delay step. Finite detector bandwidth during a fast phase sweep also suppresses every trace. Repeating the sweep more slowly and reversing its direction distinguishes that response delay from a static polarisation transformation.

Determine what a rotating analyser can detect

Compare projections of a polarised field. Identify which polarisation information is missing from a scan with only a linear analyser.

Worked inverse problem · distinguish a retarder error from source ellipticity

A linear input is sent through a retarder whose fast axis defines the horizontal direction. The input makes \(45^\circ\) to that axis. A diagonal analyser records a normalised Stokes component \(s_2=0.100\); a circular analyser gives \(|s_3|=0.990\). Determine possible retardance values, then design a measurement separating imperfect retardance from a slightly elliptical input. Assume no diattenuation for the first inference.

Track the phase and design an independent preparation

The equal input components acquire a relative phase \(\delta\) while keeping equal intensities. The outgoing Stokes components are \(s_1=0\), \(s_2=\cos\delta\), with \(|s_3|=|\sin\delta|\). The first measurement gives \(\delta=84.26^\circ\) or \(275.74^\circ\) modulo one full turn. Both predict \(|s_3|=0.995\), close to the reported 0.990. A signed, calibrated circular analyser selects the sense of the quarter-wave action, provided the basis and time convention are stated. Measuring two intensities more precisely cannot tell a one-quarter from a five-quarter retardance at a single frequency.

If the input already possessed relative phase \(\delta_i\), the observation measures \(\delta+\delta_i\). Bypass the retarder and reconstruct the input. Then rotate the retarder by \(90^\circ\) to exchange its two eigenaxes while holding the input and detector fixed. The retarder-induced phase changes sign; the source phase does not. Two signed phase measurements can recover the sum and difference, modulo ambiguities eliminated by a nearby wavelength or a known approximate plate order.

Record the calibrated horizontal and vertical transmissions as well. Differential loss makes the two output amplitudes unequal and reduces the accessible circular Stokes component even at perfect quarter-wave phase. A measured degree less than one can result from averaging several slightly different retardances across a finite spectrum. Changing the spectral filter tests that hypothesis. These checks illustrate how independent preparations constrain a device and source separately, where one very precise polarisation measurement of their combination cannot.

A rotating source exposes the detector's averaging time

Imagine an otherwise perfectly linearly polarised beam whose axis rotates uniformly during an exposure. At every instant its degree of polarisation is one. A horizontal analyser transmits an intensity proportional to the squared cosine of the axis angle, and a diagonal one samples the same function displaced by forty-five degrees. Over a complete rotation their average intensities are equal. A circular analyser also receives half the total power. Time-integrated tomography would therefore assign zero net polarisation to the exposure.

For a shorter exposure covering an angular sweep \(\Delta\) about a central angle, average the complex combination \(s_1+i s_2=e^{2i\theta}\) uniformly over the sweep. Its magnitude becomes \(|\sin\Delta/\Delta|\). A ninety-degree sweep retains a degree of approximately 0.637, whereas a full half-turn yields zero because an unoriented linear polarisation axis repeats every half-turn. The reported degree can thus identify neither instantaneous purity nor temporal stability without an exposure model.

Repeat the measurement with shorter synchronised gates and accumulate many exposures starting at the same rotation phase. Stable rotation should recover the predicted phase-resolved Stokes trajectory. A genuinely random uncorrelated orientation cannot be recovered by simply synchronising to an unrelated clock. If the analyser states are acquired sequentially, synchronise their gates too; otherwise different components may sample different portions of the trajectory and combine into a physically impossible vector.

Tutorial · recover a missing analyser setting and audit positivity

A pair of equal-throughput linear analysers reports \(I_x=4,\ I_y=2\) and \(I_{45}=4.5\) in the same power units. Find the predicted −45° reading and bound a possible circular contrast. A circular analyser then reports \(I_+=6.0\). Can these measurements describe a single stationary ensemble?

Reconstruct only what the measured subspace determines

The orthogonal sum fixes \(S_0=6\), hence \(I_{-45}=1.5\), \(S_1=2\), and \(S_2=3\). Remaining positivity requires \(S_3^2\le6^2-2^2-3^2=23\), so \(|S_3|\le4.796\). A positive circular reading of 6 would imply \(I_-=0\) and \(S_3=6\). That would make the reconstructed coherency matrix have a negative smaller eigenvalue. Merely normalizing all six readings by their common sum would retain the inconsistency. Check gain, background, plate retardance and whether the source changed during sequential measurements. If data have known statistical error, fitting J subject to positive semidefiniteness can enforce physical consistency while exposing the residuals.

Tutorial · distinguish delay decorrelation from an unresolved doublet

Two equal narrow spectral lines are separated by 80 GHz, the arms have equal powers, and polarizations match. Obtain the fringe-visibility envelope. Find the first null and first revival in optical path difference. A single visibility reading at the null is compatible with several physical explanations. Propose a scan that tests the doublet hypothesis.

Add the complex correlations before taking the magnitude

Each narrow line contributes a phase at its optical frequency. Averaging the two phasors gives \(e^{i2\pi\nu_0\tau}\cos(\pi\Delta\nu\,\tau)\), so visibility is \(|\cos(\pi\Delta\nu\,\tau)|\). The first null occurs at \(1/(2\Delta\nu)=6.25\) ps, or 1.87 mm path difference. The first revival is at 12.5 ps or 3.75 mm. In a Michelson instrument those mirror travels are 0.937 and 1.87 mm. For real spectral lines of finite width the revival sits under their own coherence envelope. Scan beyond the first null, independently match arm powers and verify polarization. A clean revival distinguishes a narrow doublet from a single broad Gaussian spectrum reproducing the same initial contrast loss.

MIT 2.71 Optics · polarisation, interference and spatial coherence

Oblique interfaces and films whose reflections cancel

A film only one quarter of a wavelength thick can suppress reflection from a transparent surface. Follow the boundary conditions all the way from an oblique incident wave to the input admittance of a stack, then calculate how much reflection returns when the wavelength, angle or layer order changes.

Tangential phase is an observable condition at an extended interface

Let the plane z=0 separate two homogeneous, lossless, isotropic dielectrics. Incident light lies in the xz plane and travels towards positive z. Use phasors \(\exp[i(k_x x+k_z z)-i\omega t]\); choose square roots for transmitted waves so energy flows away from the interface, or evanescent fields decay into the second medium. Linear time-independent boundary conditions hold at every point x and time t. If their Fourier factors had unequal \(k_x\) or \(\omega\), cancellation of the tangential boundary fields at every x,t would be impossible. Thus incident, reflected and transmitted waves share both quantities. The reflected z component reverses sign. The transmitted normal component follows from its own medium's dispersion relation.

\[k_x=k_0 n_1\sin\theta_1=k_0 n_2\sin\theta_2,\]
\[k_{zj}=\sqrt{k_0^2n_j^2-k_x^2},\]
\[k_0=\omega/c.\]

The angles are measured from the normal. Equality of tangential phase gives Snell's law independently of a ray argument, and remains useful when the normal wavenumber becomes imaginary and a real ray angle no longer exists. For example, vacuum light at 600 nm falling at 45° onto a dielectric of index 1.50 has \(k_x=7.40\times10^6\) m⁻¹ and \(\theta_2=28.1^\circ\). Relative phase across a pair of boundary probes at fixed separation along x must be the same whether they detect the incident or transmitted wave. Applying a different frequency-dependent normal propagation constant in each material does not violate that observation.

Reduce each polarization to one tangential electric amplitude

Define s polarization with E along y and p polarization with H along y. For s let \(e=E_y,\ h=-H_x\); for p let \(e=E_x,\ h=H_y\). Both choices make normal average flux \(\operatorname{Re}(e h^*)/2\). Maxwell's curl relation \(\mathbf H=(\mathbf k\times\mathbf E)/(\mu\omega)\), together with \(\mathbf k\cdot\mathbf E=0\), gives for a forward wave \(h=Ye\) and for a reverse wave \(h=-Ye\), where

\[Y_s={k_z\over\mu\omega}={\cos\theta\over Z},\]
\[Y_p={\epsilon\omega\over k_z}={1\over Z\cos\theta}.\]

For p polarization e is the tangential projection of the total E vector. Many optics tables use a reflected p basis whose tangential component flips sign on reflection. The resulting p reflection coefficient differs in sign from this tangential-e coefficient; predicted powers and a consistent full electric field agree. Here all layers use the same laboratory tangential axes, which removes unnecessary sign conversions between interfaces.

In the absence of free surface currents the two tangential boundary conditions give

\[e_i+e_r=e_t,\ Y_1(e_i-e_r)=Y_2e_t.\]

Solving for reflected and transmitted tangential amplitudes yields

\[r={Y_1-Y_2\over Y_1+Y_2},\]
\[t=1+r={2Y_1\over Y_1+Y_2},\]
\[R=|r|^2,\]
\[T={\Re Y_2\over\Re Y_1}|t|^2 .\]

For lossless propagating waves Y is real and \(R+T=1\) follows by expanding the two squared binomials. The amplitude transmission can exceed one when transmitted admittance is smaller, because energy is proportional to admittance times squared tangential field. Omitting the admittance factor leads to failed power balance even if the two field equations were solved perfectly. At normal incidence into index 1.5 from air, r=−0.20, t=0.80, R=0.04, and T=\(1.5(0.80)^2=0.96\).

Distinguish Brewster cancellation from total internal reflection

For positive nonmagnetic indices, p reflection vanishes when \(n_1/\cos\theta_1=n_2/\cos\theta_2\). Combined with Snell's law this yields \(\tan\theta_B=n_2/n_1\) at a nontrivial interface. At that angle p admittances match even while phase speed and ray direction differ across the boundary. At air-to-glass incidence with index 1.5 the Brewster angle is 56.31°. The s reflection at that same angle is substantial because s admittance varies with cosine in the opposite direction. A measurement of an intensity minimum only approximately zero can reflect polarization impurity, absorption or a surface film; a minimum angle alone cannot establish all three properties.

If \(n_1>n_2\), transmission at incidence above \(\theta_c=\arcsin(n_2/n_1)\) gives

\[k_{z2}=i\alpha.\]

The decaying exponential satisfies the same tangential phase matching. For a single semi-infinite lossless second medium its admittance is imaginary, so T vanishes and \(|r|=1\). A finite evanescent field remains on the low-index side and carries energy parallel to the surface. For glass index 1.50 facing air at 50° incidence and 600 nm vacuum wavelength, \(\alpha=k_0\sqrt{(1.5\sin50^\circ)^2-1}\approx5.93\times10^6\) m⁻¹. The electric amplitude decays to \(1/e\) in about 169 nm; intensity in about 84.5 nm. A second high-index surface within that region changes the boundary condition and can admit transmitted power.

Locate the Brewster zero and total-reflection threshold for two dielectric indices

Propagate a forward and a backward field through one film

For a film of thickness d the entrance phasors are \(e_0=A+B,\ h_0=Y(A-B)\). At the exit they are \(e_d=Ae^{i\delta}+Be^{-i\delta},\ h_d=Y(Ae^{i\delta}-Be^{-i\delta})\), with \(\delta=k_zd\). Eliminate A and B to propagate the exit fields back to the entrance:

\[\begin{bmatrix}e_0\\h_0\end{bmatrix}=\begin{bmatrix}\cos\delta&-i\sin\delta/Y\\-iY\sin\delta&\cos\delta\end{bmatrix}\begin{bmatrix}e_d\\h_d\end{bmatrix}.\]

A one-line formula conceals useful checks. At zero thickness the matrix is the identity. Its determinant is one because \(\cos^2\delta+\sin^2\delta=1\). At a half-wave thickness the matrix is minus the identity; both amplitudes change sign and their ratio is unchanged. For a stack, form the product in physical order from entrance to exit because each matrix here maps its own exit backward. Reversing two layers can change the response. For very thick evanescent layers transfer matrices contain exponentially large and small entries; a scattering matrix or scaled recursion can avoid catastrophic loss of precision.

If the substrate is semi-infinite and admits only an outgoing wave, its boundary admittance is \(Y_b=h_d/e_d\). Divide the two matrix rows to obtain

\[Y_{\rm in}={Y_b\cos\delta-iY\sin\delta\over\cos\delta-i(Y_b/Y)\sin\delta}.\]

Reflection from the whole film at its entrance now follows from the same single-interface equation with \(Y_2=Y_{\rm in}\). At a quarter wave, \(\delta=\pi/2\), this simplifies to \(Y_{\rm in}=Y^2/Y_b\). From the incident medium the film and substrate look perfectly matched if \(Y=\sqrt{Y_0Y_b}\). The field in the film still contains both travelling directions; zero reflected field at the entrance fixes a coherent sum of all returns. Adding reflected intensities interface by interface would destroy the interference responsible for the matching.

Design a coating and predict an out-of-band reading

At normal incidence choose \(n_0=1,\ n_b=2.25\), with no magnetic response. The required coating index is 1.50. At \(\lambda_0=600\) nm choose \(d=\lambda_0/(4n)=100\) nm. The uncoated substrate reflects \(R=[(1-2.25)/(1+2.25)]^2=0.148\). The ideal coated substrate has R=0 at design wavelength. A half-wave optical thickness instead returns the original admittance and restores the 14.8% reflection. These two limits can detect a factor of two in a code that confuses a one-way phase with a round-trip phase.

For a single film the same result follows by summing multiple reflections. Let \(r_{ij}=(Y_i-Y_j)/(Y_i+Y_j)\). Each additional round trip contributes \(r_{10}r_{12}e^{2i\delta}\). Summing the geometric series and using \(r_{10}=-r_{01}\) yields

\[r=(r_{01}+r_{12}e^{2i\delta})/(1+r_{01}r_{12}e^{2i\delta}).\]

In the quarter-wave example both interface coefficients are −0.20. If wavelength shifts to 500 nm at fixed indices, \(\delta=0.6\pi\). The reflected power is \(0.04[2+2\cos(1.2\pi)]/[1+0.04^2+0.08\cos(1.2\pi)]\approx0.0163\). The coating still reduces reflection relative to the bare substrate, but a strictly zero field requires the design phase and amplitudes to match.

At oblique incidence the phase uses the film's normal wavenumber, giving \(\delta=2\pi n d\cos\theta_{\rm film}/\lambda_0\). Increasing incidence angle shortens the design wavelength that achieves the same phase. At the same time the matching admittances change differently for s and p, so keeping only the phase shift is incomplete. For illumination by a focused beam a range of tangential wavenumbers reaches the substrate. A single normal-incidence calculation cannot predict its whole cone's reflection without an angular/polarization weighting.

Build a finite dielectric mirror from admittance transformations

Suppose the incident side sees an alternating high-index H and low-index L layer, each quarter-wave thick at normal incidence. Starting at the substrate admittance \(Y_b\), the last low layer gives \(Y_L^2/Y_b\); the preceding high layer transforms that to \(Y_b(Y_H/Y_L)^2\). Repeating N pairs yields

\[Y_{\rm in}=Y_b(Y_H/Y_L)^{2N}.\]

The growth is geometric in pair count despite each individual interface reflecting only a fraction of the wave. This is a coherent reflection measurement and depends on all pair phases staying near their design values.

Take \(n_H=2,\ n_L=1.5,\ n_0=n_b=1.5\). With three HL pairs the normalized input admittance is \((4/3)^6=5.62\) times its external value, giving R about 0.487. With six pairs the ratio is \((4/3)^{12}=31.6\), giving R about 0.881. The same total number of random-thickness layers need not achieve those values. Swapping HL for LH in the symmetric exterior configuration inverts the input admittance ratio. It reverses the reflected field phase while leaving the centre-wavelength reflected intensity unchanged. Phase-sensitive reflection can therefore distinguish two stacks with identical intensity at one wavelength.

A stack on a substrate different from the input medium removes that simple intensity degeneracy. The layer order can then alter centre-wavelength reflected intensity as well. Fabrication tolerances introduce additional phase shifts and can split spectral extrema. To identify a real film from measured data, compare phase or several wavelengths and polarization states, and account for instrument spectral width. One scalar normal-incidence reflectance generally admits many index-thickness pairs.

From a stack of interfaces to a spectral ruler

A pair of parallel partially reflecting surfaces makes more than a mirror. A short incident pulse emerges as a train of diminishing replicas, and a continuous wave samples their coherent sum. Work first at normal incidence in a lossless gap of refractive index \(n\) and thickness \(L\). Identical ideal mirrors have intensity reflectance \(R\). An extra round trip therefore multiplies a transmitted field by \(R e^{i\delta}\), where \(\delta=2n\omega L/c\) plus any frequency-independent mirror phase. At a resonance this phase is an integer multiple of \(2\pi\). The directly transmitted field magnitude contains the product of the two mirror transmissions, \(1-R\) in the symmetric lossless case. Sum the geometric series and take the magnitude squared.

\[\frac{I_{\rm out}}{I_{\rm in}}=\frac{(1-R)^2}{|1-Re^{i\delta}|^2}=\frac{1}{1+F\sin^2(\delta/2)},\]
\[F=\frac{4R}{(1-R)^2}.\]

The unit transmission at resonance follows from interference and symmetry. It does not imply that the mirrors transmit the whole incident wave on the first encounter. At the front surface a leaked internal wave cancels the directly reflected wave. During switch-on energy accumulates in the gap, so imposing the steady resonance formula on the leading edge of a finite pulse would violate the assumed steady state. If the two mirrors have different transmissions or the gap absorbs, the two reflected amplitudes at the entrance no longer necessarily cancel at resonance.

Adjacent maxima differ in ordinary frequency by \(c/(2nL)\) if dispersion and mirror phase slopes are negligible. If the material phase \(n\omega L/c\) is dispersive, differentiate the round-trip phase. The local mode spacing becomes the inverse of the round-trip group delay, including the frequency derivative of reflective phase. Replacing \(n\) by a phase index measured far from that frequency can then bias an inferred length. At an oblique angle, decide whether the scan holds external angle or tangential wavevector fixed before differentiating the phase.

For \(L=10.0\) mm, \(n=1.50\) and \(R=0.81\), the free spectral range is 9.99 GHz. The half-power points satisfy

\[\sin^2(\delta/2)=1/F.\]

Their full frequency separation divided by one free spectral range is \(2\arcsin(1/\sqrt F)/\pi\). Here \(F=89.75\) and the linewidth is about 0.673 GHz. The finesse, spacing divided by linewidth, is 14.9. The familiar high-reflectance approximation \(\pi\sqrt R/(1-R)\) also gives 14.9. For a very weak mirror there need not be half-maximum points at all because the minimum remains above half the peak. The exact formula tells you when a linewidth extracted by that convention is undefined.

Verify the same length in time and find a small hidden loss

The energy of a freely decaying intracavity pulse is multiplied by \(R^2\) each round trip for identical mirrors. With round-trip time \(t_r=2nL/c\), the continuous exponential through the discrete samples has energy lifetime \(\tau_E=-t_r/[2\ln R]\). For the above gap \(t_r=100.1\) ps and \(\tau_E=238\) ps. Its reciprocal \(1/(2\pi\tau_E)\) is 0.670 GHz, close to the direct linewidth. This equality is an approximation to the isolated narrow resonance. A short enough pulse can resolve the individual replicas and reveal directly that the idealised trace is a train, not a continuously measured exponential at every instant.

Now introduce a weak internal loss. Let \(a\) be the intensity fraction remaining after one pass through the material. An additional round trip multiplies the circulating field by \(Ra\), while the direct transmitted intensity is multiplied by \(a\). Thus the resonant transmission and freely decaying energy factor are

\[T_{\rm peak}=\frac{(1-R)^2a}{(1-Ra)^2},\]
\[g_E=R^2a^2 .\]

If the measured ratio of successive isolated replicas is 0.630, assuming the mirrors still have \(R=0.81\) gives

\[a=\sqrt{0.630}/0.81=0.980.\]

The predicted peak transmission is about 0.83, substantially below one despite the small two-percent single-pass loss. Multiple passes amplify the effect of absorption. Energy reflected in the mode, absorbed in the gap and transmitted are separate channels. A detector collecting only the central transmitted lobe can also show a low peak when the incident beam couples poorly to the cavity, even with very low material absorption.

An inference procedure uses an intensity-calibrated bypass beam to determine the incident power, a direct time spacing to estimate \(n_gL\) and ringdown ratios to estimate \(Ra\). If \(R\) is unknown, ringdown alone constrains only the product. A resonant transmission measurement supplies a second equation in the ideal symmetric setup, but beam mismatch and mirror imbalance add unknowns. Block one mirror or measure it separately to obtain an independent reflectance. Small thermal changes of gap length shift the resonance between repeated readings. Sweep the frequency and fit the full peak instead of observing its height at a single nominally resonant wavelength.

Finally examine a common interpretation trap with broadband illumination. A spectrometer pixel integrating many evenly spaced narrow resonances reports their average transmission, while a narrow-line source scanned sufficiently slowly recovers their maxima and minima. The difference is predicted by averaging the intensity spectrum with the instrument response, not by summing the fields emitted from mutually incoherent source frequencies. Conversely the repeated passes of a single resolved frequency are mutually coherent and must be summed as fields. The same device contains both averaging operations, in a definite order. This order follows from the detector integration time and the source correlations.

Apply the interface conditions to a measurable power ratio

Change incidence angle and the receiving medium. Compare amplitude reflection with the power that actually crosses the interface.

Worked boundary problem · where does the energy of a totally reflected wave go?

A lossless glass prism with refractive index 1.50 is illuminated internally at \(50^\circ\), adjacent to air. Vacuum wavelength is 600 nm. Calculate the phase propagation along the interface, the normal field decay length in air and the associated one-sided intensity decay length. Can a detector in the second medium remove power without changing the reflection problem?

Evaluate the complex wavevector and its physical flux

Continuity of tangential phase gives

\[k_x/k_0=1.50\sin50^\circ=1.149.\]

The normal air wavenumber has imaginary part \(\kappa=k_0\sqrt{1.149^2-1}=0.566\,k_0\), giving amplitude decay length \(1/\kappa=169\) nm. Squared field decays over about 84.5 nm. The tangential phase period is

\[\lambda_0/1.149=522\,\mathrm{nm}.\]

Treating this as an air plane wave with a real propagation direction would imply an impossible sine and lose the normal decay that satisfies the boundary condition.

For s polarisation take \(E_y\propto e^{ik_xx-\kappa z}\). The wave equation gives

\[H_x=-i\kappa E_y/(\mu\omega),\]
\[H_z=k_xE_y/(\mu\omega).\]

In \(\operatorname{Re}(\mathbf E\times\mathbf H^*)/2\), the normal component vanishes because the needed product is purely imaginary, but the tangential component is positive. A finite evanescent field thus accompanies unit reflected power at this ideal isolated interface. Zero time-averaged normal flux does not require a zero field in the adjacent material.

Introducing a second prism or a genuinely absorbing near-field probe changes the boundary condition. A field returning from the second boundary permits interference that can carry normal energy. A perfectly calibrated detector nevertheless perturbs the solution if it extracts appreciable power. Increase the air gap and compare the recovery of unit reflectance as well as the detected signal. A decay in detected intensity alone could also reflect geometric collection changes, while agreement with the complementary reflected-power change constrains the power path.

A wedge turns phase dispersion into a spatial measurement

Two plates forming a small air wedge provide a complementary way to measure a layer without scanning the source frequency. Let the gap rise linearly with transverse position at small angle \(\alpha\). In reflection at nearly normal incidence successive equivalent fringes correspond to a full additional round-trip phase, hence to an added gap of half a wavelength in the intervening medium. For a 633 nm source and a measured fringe spacing of 0.80 mm in air, the inferred wedge slope is about 0.396 milliradians. The phase reversals on the plates choose whether the contact end is bright or dark but do not change this spacing.

If the refractive index is unknown, a single spacing constrains only the product of gap slope and index. An independent surface-profile measurement provides the geometric slope. Alternatively fill the same wedge with a transparent fluid and compare its spacing against air, keeping geometry and temperature fixed. The ratio of air spacing to fluid spacing measures the ratio of indices within the local parallel-film approximation.

Several identifiable departures can occur. A finite camera pixel averages neighbouring fringes, a broad source loses contrast with increasing path difference and a curved plate produces a changing fringe spacing. The first two principally reduce visibility; the third changes local phase gradient. Fit fringe positions and their visibility as separate observables before attributing either effect to absorption inside the film.

Tutorial · measure a Brewster index and bound an unwanted polarization

A transparent nonmagnetic sample in air has an observed p minimum at \(58.0^\circ\). Assume for this estimation that it is a single dielectric interface. Infer its index, calculate the s reflectance there, and estimate what fraction of incident power could be s-polarized if the measured minimum reflectance is 0.0040 and all other backgrounds are negligible.

Derive and use the second polarization as a calibration

The inferred index is

\[\tan58^\circ=1.600.\]

At the Brewster angle the transmitted angle is \(32^\circ\). Relative s admittance is \(n\cos32^\circ/\cos58^\circ=n^2\) for air incidence. Thus \(R_s=[(1-n^2)/(1+n^2)]^2\approx0.192\). An incident s fraction f contributes \(fR_s\) to reflected power while the ideal p component contributes zero. Matching 0.0040 gives \(f=0.0208\), about 2.1%. This is an upper bound if another nonnegative reflected background is present. Absorption or a coating can also displace the minimum, invalidating the simple index fit itself. Measuring the complementary s curve and checking transmitted power provide independent tests before interpreting the impurity.

Tutorial · separate a thickness error from an index mismatch

A nominal 600 nm quarter-wave coating with design index 1.5 on an index 2.25 substrate is measured to be 102 nm thick. First hold all indices fixed. Predict the wavelength of its exact null, then estimate R at 600 nm to leading order. If its index is actually 1.55, can changing only the thickness recover an exact null?

Expand the coherent reflection and apply the admittance condition

The quarter-wave wavelength is \(4nd=612\) nm. At 600 nm the phase deviates from \(\pi/2\) by \(\Delta=\pi(0.02)/2=0.0314\). With \(r_{01}=r_{12}=r_s=-0.20\), the small-amplitude reflection is \(r\simeq-2i r_s\Delta/(1-r_s^2)\). Thus \(R\simeq4r_s^2\Delta^2/(1-r_s^2)^2=1.71\times10^{-4}\). An index of 1.55 gives unequal magnitudes at the two interfaces. Varying the phase can put their return fields in opposition but cannot equalize their magnitudes. At a quarter wave the best input admittance is proportional to \(1.55^2/2.25=1.0678\), giving R about 0.00107. A wavelength scan can locate the minimizing optical thickness while the depth of that minimum constrains the impedance mismatch.

MIT 6.013 · boundary conditions, oblique waves, impedance transformations and layered systems

Causal material response and the propagation of a finite pulse

An optical pulse entering a transparent slab is delayed, broadened and sometimes reshaped. Derive these effects from the motion of bound charge, and learn what a measured group delay actually says about a pulse carrying information.

Turn the idea of delayed response into an equation

At a point in a stationary isotropic dielectric, a short electric impulse displaces bound charge. The displacement can continue after the applied field disappears. In a linear time-translation-invariant material write the polarization as a weighted sum over earlier values of the local electric field:

\[P(t)=\epsilon_0\int_0^\infty h(\tau)E(t-\tau)\,d\tau,\]
\[\chi(\omega)=\int_0^\infty h(\tau)e^{i\omega\tau}\,d\tau .\]

The lower limit encodes causality. Switching to steady harmonic fields yields \(\widetilde P=\epsilon_0\chi(\omega)\widetilde E\) under the \(e^{-i\omega t}\) convention. An instantaneous contribution could also be represented by a delta function at zero delay. The response kernel h has dimensions of inverse time when susceptibility is dimensionless. A short memory compared with the period can sometimes be approximated by a constant susceptibility over a limited band. Extending a constant complex response to all frequencies would generally violate either causality or the requirement of a real time-domain polarization.

For real h, \(\chi(-\omega)=\chi(\omega)^*\), so its real part is even and its imaginary part odd. For a decaying kernel, extending \(\omega\) into the upper half of the complex plane introduces \(e^{-\operatorname{Im}\omega\,\tau}\), ensuring convergence. Analyticity there links dispersion and absorption. Conversely, a fitted pole in the upper half-plane in this convention would imply growth, an incompatible time convention, or an unstable model. Report the phasor convention beside an empirical complex permittivity to assign the sign of loss correctly.

Obtain a susceptibility with a recognizable resonance

Represent a bound charge of magnitude q and mass m by a displacement x, restored with frequency \(\omega_0\) and damped at rate \(\gamma\). Choose x along the direction of the force on a positive effective charge; the resulting susceptibility depends on \(q^2\). For a density N of independent oscillators the polarization is \(Nqx\). The equation of motion and its phasor solution give

\[m(\ddot x+\gamma\dot x+\omega_0^2x)=qE,\]
\[\chi={\omega_p^2\over\omega_0^2-\omega^2-i\gamma\omega},\]
\[\omega_p^2={Nq^2\over m\epsilon_0}.\]

Writing \(D=(\omega_0^2-\omega^2)^2+\gamma^2\omega^2\) gives

\[\chi'=\omega_p^2(\omega_0^2-\omega^2)/D,\]
\[\chi''=\omega_p^2\gamma\omega/D.\]

A positive damping rate makes \(\chi''>0\) at positive frequency. At low frequency the displacement follows the drive almost in phase, while far above resonance inertia produces the opposite displacement. At resonance the displacement lags the drive by a quarter cycle, making the velocity align with force and maximizing the ability of damping to absorb average work for a given displacement amplitude.

The energy balance follows directly by multiplying the equation by \(N\dot x\). The field supplies \(E\dot P\), equal to the rate of change of oscillator kinetic plus restoring energy and the dissipated power \(Nm\gamma\dot x^2\). Averaging a harmonic cycle eliminates the change of stored mechanical energy. With peak phasors,

\[\langle E\dot P\rangle=\tfrac12\omega\epsilon_0\chi''|\widetilde E|^2=\tfrac12 Nm\gamma\omega^2|\widetilde x|^2 .\]

This supplies a practical sign check on both the material fit and the assumed time dependence. The imaginary part that attenuates a passive forward wave must also give nonnegative cycle-averaged heating.

Reconstruct the dispersive shift from its loss spectrum

For a response that vanishes sufficiently fast at high frequency, analyticity in the upper half-plane permits a contour integral of \(\chi(z)/(z-\omega)\). Close the contour above and indent around the pole on the real axis. The large arc vanishes under the decay assumption. Taking real and imaginary parts of the resulting principal-value relation, then using the symmetry between positive and negative frequencies, gives

\[\chi'(\omega)={2\over\pi}\,\mathcal P\int_0^\infty{\Omega\chi''(\Omega)\over\Omega^2-\omega^2}\,d\Omega .\]

The principal value means combine contributions on both sides of the singular frequency before taking the limit. At zero frequency there is no interior singularity and \(\chi'(0)=(2/\pi)\int_0^\infty\chi''(\Omega)/\Omega\,d\Omega\). A passive absorption band produces a finite static polarization contribution even when it lies far above the optical frequencies being measured. If instantaneous high-frequency polarization is included in a model, subtract that constant background before using this vanishing-at-infinity form.

As a simple check, let a measured narrow absorption band have area \(A=\int\chi''\,d\Omega=3.0\times10^{14}\) s⁻¹ centered at \(\Omega_0=2.0\times10^{15}\) s⁻¹. Across the band \(1/\Omega\) varies little, giving an estimated contribution \(2A/(\pi\Omega_0)=0.0955\) to \(\chi'(0)\). The same numerical area translated to twice the frequency contributes only half as much. A spectrometer limited to one window cannot recover an absolute static susceptibility without assumptions about absorption outside its window. Tail models and independent low-frequency measurements constrain this extrapolation.

Distinguish the carrier phase from the envelope delay

In a nonmagnetic bulk medium define \(k(\omega)=\omega n(\omega)/c\), choosing the branch of n that attenuates a wave travelling in positive z. A component accumulates \(\exp[ik(\omega)L]\), so its field amplitude decays as \(\exp[-\operatorname{Im}k\,L]\) and its intensity twice as rapidly in the exponent. In a transparent band take k effectively real and expand around carrier \(\omega_c\):

\[k(\omega_c+\Omega)=k_c+k_1\Omega+\tfrac12 k_2\Omega^2+\cdots,\]
\[k_1={1\over v_g}={n+\omega_c\,dn/d\omega\over c}.\]

The constant \(k_cL\) rotates the carrier phase. The term \(k_1L\,\Omega\) multiplies the envelope spectrum by a linear phase, corresponding to translation in time by \(k_1L\). The second derivative produces different delays for different spectral components and generally changes the pulse shape. These three operations can be measured separately with an interferometer, a time-of-flight experiment and a pulse-duration measurement. A continuous-wave phase measurement at one frequency does not independently determine \(k_1\) or \(k_2\).

At 800 nm suppose an index measurement gives \(n=1.50\) and \(dn/d\lambda_0=-0.050\) per μm, where \(\lambda_0\) is vacuum wavelength. By differentiating \(\omega=2\pi c/\lambda_0\),

\[n_g=n-\lambda_0\,dn/d\lambda_0=1.54.\]

A 100 mm slab has carrier phase travel time \(nL/c=0.5003\) ns and narrowband envelope time \(n_gL/c=0.5137\) ns. Compared with a vacuum path of equal length the envelope delay is \(0.1801\) ns. The 13.3 ps difference between phase and group times is small relative to a nanosecond but enormous compared with a 50 fs pulse width.

Derive the width of a dispersed Gaussian by completing a square

Use an input envelope \(A(0,t)=A_0\exp[-t^2/(2T_0^2)]\), so its intensity is proportional to \(\exp[-t^2/T_0^2]\). The amplitude spectrum is proportional to \(\exp[-T_0^2\Omega^2/2]\). In a frame at retarded time \(u=t-k_1L\), multiplication by the quadratic propagation phase gives a Gaussian integral with complex coefficient \(T_0^2-i k_2L\). Evaluate that integral with its physical square-root branch:

\[{A(L,u)\over A_0}={1\over\sqrt{1-iD}}\exp\!\left[-{u^2\over2T_0^2(1-iD)}\right],\]
\[D={k_2L\over T_0^2}.\]

Hence \(I(L,u)=I_0(1+D^2)^{-1/2}\exp[-u^2/(T_0^2(1+D^2))]\). The intensity width broadens by \(\sqrt{1+D^2}\) and the peak falls by the reciprocal factor. Integrating over u recovers the original pulse energy per area, as expected for lossless propagation. The phase inside the exponential is quadratic in u, so the instantaneous frequency varies across the envelope. Measuring only output intensity cannot tell the sign of \(k_2\), since the width depends on its square. A phase-sensitive measurement or a known initial chirp can reveal that sign.

Take \(T_0=20\) fs and integrated dispersion \(k_2L=400\) fs². Then D=1. The incident intensity FWHM is \(2\sqrt{\ln2}T_0=33.3\) fs, and the emerging FWHM is 47.1 fs. The peak intensity falls to 70.7% while the energy remains fixed. In a second slab of the same length with \(k_2L=-400\) fs², the quadratic phases cancel, provided loss and higher-order dispersion remain negligible and the beams couple without appreciable filtering. Propagating with group velocity alone would predict the arrival of the centre but miss these measurable width changes.

When a measured peak time no longer tracks an unaltered envelope

Near an absorption line both real and imaginary parts of k can vary strongly over a pulse spectrum. A simple propagation experiment then applies a complex filter \(H(\omega)=t_{\rm interfaces}(\omega)e^{ik(\omega)L}\), where interface reflections may also matter. A severely attenuated output maximum may move forward because the trailing part of the incoming waveform is preferentially removed. A negative slope of the transmission phase can therefore coexist with a causal impulse response. The arrival of a newly imposed nonanalytic wavefront requires the high-frequency behaviour of the full causal transfer function. A band-limited Gaussian already has tails at every finite time and has no sharp front.

There is also a distinction between phase delay and energy deposition in an opaque medium. If \(n=n'+i n''=1.5+0.02i\) at 600 nm, \(\operatorname{Im}k=2\pi(0.02)/\lambda_0=2.09\times10^5\) m⁻¹. Ignoring reflections, intensity falls to \(1/e\) in \(1/[2\operatorname{Im}k]=2.39\) μm. After 5.0 μm the intensity fraction is

\[e^{-2.094}=0.123.\]

A pulse delay inferred from the remaining photons is a conditional timing measurement on transmitted energy; it does not describe energy that was deposited at shallower depths.

Separate a resonance shift, a loss peak and a spectral weight

In the oscillator calculation, hold oscillator strength fixed and compare two damping rates. Predict the imaginary susceptibility at resonance from \(\omega_p^2/(\gamma\omega_0)\); halving damping should double this height. The static susceptibility \(\omega_p^2/\omega_0^2\) stays fixed. A narrower taller peak can preserve its weighted spectral contribution. Record real susceptibility on both sides of the resonance, where its sign changes. Then change the oscillator strength and explain why this change scales absorption and dispersion together. Use the separate half-space calculation to check that the absorbed power integrated over depth accounts for the part of incoming flux that passes the surface.

Change damping in the bound-charge susceptibility experiment

Check how integrated heating closes an energy balance

A causal relaxation whose spectrum can be integrated exactly

As a second material model, consider permanent molecular dipoles that reorient toward a weak applied field. When rotational inertia relaxes much faster than the times of interest, a single exponential approach to equilibrium is useful. Let the additional static susceptibility of these dipoles be \(\Delta\chi\), and let \(\tau\) be the relaxation time. For the extra polarisation write \(\tau\dot P+P=\epsilon_0\Delta\chi E\). This is a different material approximation from a weakly damped oscillator. It still has a retarded response and provides an independent test of the dispersion–loss relation.

Solve the inhomogeneous differential equation by multiplying it by \(e^{t/\tau}\), integrating from an unpolarised remote past and dividing by the same factor. A unit step turns on exponentially. A harmonic drive gives a complex susceptibility with one pole on the lower imaginary frequency axis for the chosen \(e^{-i\omega t}\) sign convention.

\[P(t)=\frac{\epsilon_0\Delta\chi}{\tau}\int_{-\infty}^t e^{-(t-t')/\tau}E(t')\,dt',\]
\[\chi'=\frac{\Delta\chi}{1+\omega^2\tau^2},\]
\[\chi''=\frac{\Delta\chi\,\omega\tau}{1+\omega^2\tau^2}.\]

At \(\omega\tau=1\) the in-phase and lagging components are equal to \(\Delta\chi/2\), and the loss component reaches its maximum. A material with \(\tau=8.0\) ns therefore peaks near 19.9 MHz. A step reaches 63.2 percent of its final additional polarisation after 8.0 ns and 95.0 percent after 24.0 ns. If the chosen observable is current rather than polarisation, the relaxation current is proportional to \(\dot P\) after the step and decays, while \(P\) itself rises. An instantaneous background polarisation can deliver a narrow current spike in addition to this resolved tail.

Substitute \(\chi''\) into the zero-frequency dispersion relation. With \(x=\omega\tau\), the integral becomes

\[(2\Delta\chi/\pi)\int_0^\infty dx/(1+x^2)=\Delta\chi.\]

The high-frequency background, if present, must be added separately to obtain the total static response. This exact integral is also a test for loss-spectrum simulations on a logarithmic grid. The integration measure is \(d\omega/\omega=d\log\omega\). Equal weights per ordinary frequency or a missing conversion between natural and decimal logarithms gives an incorrect static increment even if the plotted peak is perfect.

A spectrometer covering \(0.1\leq\omega\tau\leq10\) captures \(2[\arctan 10-\arctan(0.1)]/\pi=0.873\) of the static increment. Two full decades centred on the peak miss almost thirteen percent. The missing low and high frequency contributions are equal in this particular symmetric logarithmic loss model. A superposition of slower relaxations or a second unrelated absorption feature destroys this equality. Report a static measurement or bounds on those extra contributions before interpreting a small discrepancy as failure of causality.

Drive the relaxation twice and distinguish memory from propagation delay

Apply a rectangular field \(E_0\) from time zero to \(T\), then switch it off. Continuity of polarisation at both switching instants gives

\[P(T)=\epsilon_0\Delta\chi E_0(1-e^{-T/\tau}).\]

After switch-off the value decays as \(P(T)e^{-(t-T)/\tau}\). For \(T=\tau\) the maximum is 0.632 of the static value and at \(2\tau\) the remainder is 0.233. A pure delay with the same time of maximum would instead translate the rectangular waveform with unchanged amplitude and abrupt edges. One can test this distinction from the complete waveform even if a slow instrument makes identifying the first nonzero response difficult.

Follow the first pulse by an opposite pulse of equal height starting after a zero-field gap \(g\). At the second start the memory is \(P_s=\epsilon_0\Delta\chi E_0(1-e^{-T/\tau})e^{-g/\tau}\). The second pulse drives the polarisation toward the opposite equilibrium. It crosses zero during the pulse after a further time \(\tau\ln[1+P_s/(\epsilon_0\Delta\chi E_0)]\). For \(T=\tau\) and \(g=\tau\) the result is \(0.209\tau\), or 1.67 ns with the above time constant. This cancellation depends on the gap. A nonlinear saturation or a detector recovery effect can also produce interactions between pulses, so repeat with smaller field and with a reference cell.

Because the material equation is linear, scaling both pulses by the same factor leaves the zero-crossing time unchanged. The delay-based measurement rejects a constant gain error, but an additive baseline shifts the crossing. An experimentally estimated timing uncertainty is the noise level divided by the local slope magnitude there. At zero polarisation within the negative pulse the equation gives \(\dot P=-\epsilon_0\Delta\chi E_0/\tau\), making the conversion from amplitude noise especially simple. This also explains why decreasing the field too far increases the timing noise even though it improves the validity of a linear material response.

To separate propagation from memory, take data through two cell thicknesses using the same cables and electronics. A phase accumulating in the material scales with thickness, while a common cable or detector lag cancels in their phase difference. Reflections give additional echoes whose times scale with thickness too, but follow round-trip distances and can interfere with the direct signal. Gate a sufficiently isolated first arrival or include interface scattering in the transfer function. Taking a ratio of Fourier spectra near a zero of the reference pulse magnifies noise; discarding or regularising those frequencies changes the reconstructed temporal resolution and should be stated with the result.

Compare absorption and phase near a resonance

Sweep the drive through a material resonance. Follow the phase response and loss separately before interpreting a pulse arrival time.

Worked pulse problem · bound a group-delay measurement

A pulse traverses two samples cut from one transparent material, of lengths 10.0 and 30.0 mm. The measured difference between the carrier-envelope peak times is 103 ps. The extra material replaces air in a fixed total optical path. Estimate the group index. A student obtains a substantially different value from the phase velocity at the carrier. Specify two physical measurements and one numerical test that can resolve the disagreement.

Use the replaced air and examine the pulse spectrum

The incremental delay is \((n_g-n_{g,\rm air})\Delta L/c\), with \(n_{g,\rm air}\) near one in this idealised setting. Thus \(n_g\simeq1+c(103\,\mathrm{ps})/(20.0\,\mathrm{mm})=2.54\). Treating the extra material path as an added path in an otherwise unchanged optical train would give 1.54 instead. A genuinely moved detector would require that different time reference and geometry. A 2 ps independent uncertainty in this differential delay alone contributes about 0.030 to \(n_g\).

First measure phase at several closely spaced frequencies and unwrap its slope. The slope gives group delay, whereas phase at one frequency determines a phase index only after fixing an integer number of waves. Second, shorten the spectrum while keeping its central frequency fixed and compare peak delay with a cross-correlation delay and a centre-of-energy delay. A strongly distorted pulse can yield three different answers even with perfect electronics. Record a transmitted spectrum for each sample to establish whether selective attenuation is significant.

As a numerical test, propagate the measured incident spectrum using the fitted complex wavenumber and reconstruct the physical detector observable, including its impulse response. Compare with the analytic linear-phase translation after suppressing higher dispersion derivatives and frequency-dependent attenuation. Keep the computational time window large when narrowing the spectrum, since the pulse then extends further in time. A wrapped pulse in a periodic FFT window can acquire an apparently early peak. Looking at the first and last portions of the unwrapped time trace is an inexpensive way to rule that out.

A deliberately chirped input reveals the sign of dispersion

The temporal width of an initially transform-limited Gaussian after propagation depends on squared group-delay dispersion. Measuring one broadened width therefore loses the sign of the quadratic phase. Add a known adjustable quadratic spectral phase before the sample. For a Gaussian with fixed spectral intensity, the broadening now depends on the square of the sum of the imposed and sample phase curvatures. Plot measured pulse width versus the imposed curvature. The minimum identifies the setting that compensates the sample and hence gives the opposite of its signed dispersion.

For example, suppose independent calibration of the phase device assigns its minimum output width to an imposed minus four hundred femtoseconds squared after inserting a plate. If the optical train without the plate minimises at minus one hundred femtoseconds squared, the plate adds plus three hundred femtoseconds squared. The displacement of the minimum removes a common phase offset from the optical train. The widths at their respective minima need not be exactly equal if the plate changes the transmitted spectrum.

Measure that spectrum before interpreting a displaced or broadened minimum. A filter narrowing the spectrum increases even the best possible transform-limited pulse width. Cubic spectral phase and detector response may make the measured width curve asymmetric or leave a long tail near the nominal optimum. Comparing a reconstructed complete temporal profile with its spectrum gives information that a single width at one propagation distance cannot contain.

Tutorial · infer a material slope with a pair of delay measurements

Two samples of the same transparent glass have lengths 20.0 and 70.0 mm. With the receiver and external air path arranged so that the added glass replaces an equal vacuum length, the narrowband arrival time differs by 90.0 ps. At 1.00 μm the independently measured phase index is 1.500. Determine group index and the local index slope. Estimate how an unaccounted fixed electronic time offset affects a two-length measurement.

Use the difference to eliminate common delays

With \(\Delta L=0.0500\) m and \(\Delta t=(n_g-1)\Delta L/c\), the inferred index is

\[n_g=1+c\Delta t/\Delta L=1.540.\]

Therefore \(dn/d\lambda_0=(n-n_g)/\lambda_0=-0.040\) per μm. A fixed additive trigger latency appears in both raw arrival times and cancels in the difference. A sample-dependent connector or surface coating that changes the pulse transmission phase need not cancel. Comparing a third length tests the assumed affine dependence of delay on material length, while measuring transmitted spectra can reveal frequency-dependent filtering.

Tutorial · distinguish dispersion from simple attenuation

An initially transform-limited Gaussian pulse has intensity FWHM 50 fs. After a transparent segment its width is 80 fs and its peak intensity is 0.50 times the original. Estimate \(|k_2L|\) under the Gaussian model, then infer the additional frequency-independent intensity transmission needed to account for the peak. Could the measured peak alone determine dispersion?

Recover a width and then an energy ratio

The initial amplitude parameter is \(T_0=50/(2\sqrt{\ln2})=30.0\) fs. The width ratio 1.60 gives

\[|D|=\sqrt{1.60^2-1}=1.249.\]

Thus \(|k_2L|\simeq1.13\times10^3\) fs². At conserved energy the peak would be \(1/1.60=0.625\), so an additional intensity transmission of \(0.50/0.625=0.80\) reconciles both observations. Equivalently the energy ratio is peak ratio times width ratio, 0.80. A peak value alone admits many combinations of filtering, dispersion and attenuation. The inference additionally assumes that higher-order spectral phase and spectral amplitude filtering do not change the Gaussian shape.

David Tong, University of Cambridge · electromagnetism in matter, dispersion and causality

A guided mode, a cavity line and the energy they carry

A microwave pulse sent through a rectangular guide arrives late even though the guide is evacuated. Terminating the guide converts the travelling pattern into a family of resonances. Use the same transverse eigenproblem to predict its cutoff, pulse delay, cavity frequency and measured linewidth.

State the longitudinal dependence before choosing a transverse basis

Let a hollow rectangular perfect-conductor guide occupy \(0<x<a,\ 0<y<b\) and extend in z. Fill it uniformly with a lossless dielectric. A single-frequency field varies as \(e^{i\beta z-i\omega t}\). In the interior each Cartesian component satisfies the Helmholtz equation. Separating the z dependence leaves the transverse equation \(\nabla_t^2F+k_c^2 F=0\), with \(k_c^2=k^2-\beta^2,\ k=\omega\sqrt{\epsilon\mu}\). Conducting walls impose zero tangential E at the perimeter. They do not impose zero H there, since surface current can flow and supply the required magnetic discontinuity.

A transverse-magnetic (TM) mode has \(H_z=0\) and uses \(E_z\) as its longitudinal scalar. Because z lies tangential to every side wall, \(E_z=0\) there. The allowed nonzero separable solutions are sine-sine products with positive integers m,n. A transverse-electric (TE) mode has \(E_z=0\) and uses \(H_z\) with vanishing outward normal derivative on the side walls. Its scalar modes are cosine-cosine products. One index may be zero but both cannot be zero in this hollow single-conductor guide. The apparent constant \(H_z\) TE00 solution fails to reconstruct a nonzero propagating transverse field from Maxwell's equations. A TEM mode can exist in a coaxial line with two conductors maintained at different potentials. A connected perfect conductor surrounding empty simply connected space admits only constant electrostatic boundary potential, precluding a nontrivial transverse potential difference for TEM.

\[k_{c,mn}^2=(m\pi/a)^2+(n\pi/b)^2,\]
\[\beta^2=\omega^2\epsilon\mu-k_{c,mn}^2,\]
\[f_{c,mn}={1\over2\sqrt{\epsilon\mu}}\sqrt{(m/a)^2+(n/b)^2}.\]

The cutoff emerges from the room a transverse standing field needs to fit between walls. It is a condition on frequency, geometry and filling material together. Below cutoff a decaying longitudinal solution can still store near fields and mediate coupling over finite lengths. A reading on the far side of a short below-cutoff section therefore need not be exactly zero.

Reconstruct one measurable field from the vector equations

Take \(a>b\) and the lowest TE10 mode. A useful choice is \(\widetilde E_y=E_0\sin(\pi x/a)e^{i\beta z}\), with \(E_x=E_z=0\). It vanishes at x walls as required. At the y walls \(E_y\) is normal and can end on surface charge. Use \(\nabla\times\widetilde{\mathbf E}=i\omega\mu\widetilde{\mathbf H}\) to reconstruct both magnetic components:

\[\widetilde H_x=-{\beta\over\omega\mu}\widetilde E_y,\]
\[\widetilde H_z=-{i\pi E_0\over\omega\mu a}\cos(\pi x/a)e^{i\beta z}.\]

Ampère's law then reproduces the dispersion relation. The negative x direction of H for positive E_y and positive \(\beta\) gives positive \(S_z\). The TE wave impedance is \(Z_{\rm TE}=\omega\mu/\beta\) using transverse magnitudes. Unlike a plane-wave impedance in a homogeneous bulk medium, this one changes with frequency even when \(\epsilon,\mu\) are constant. At cutoff transverse magnetic H_x vanishes for a fixed finite E_y, while H_z remains finite. This is why large field amplitude near cutoff need not imply substantial transmitted axial power.

Integrate power through the cross-section using \(\langle S_z\rangle=\beta|\widetilde E_y|^2/(2\omega\mu)\). The integral of \(\sin^2(\pi x/a)\) is \(a/2\). The mode therefore carries \(P=ab\,|E_0|^2/(4Z_{\rm TE})\). Using simply the area times the central peak flux would overestimate power by a factor of two. A small receiving probe samples a spatially weighted field. Its calibration can be checked by moving it from the centre to x=a/6, where field amplitude halves and local axial flux falls by a factor of four.

Compute two velocities and check them by energy transport

With bulk phase speed \(v=1/\sqrt{\epsilon\mu}\), the dispersion relation is

\[\omega^2=v^2(\beta^2+k_c^2).\]

Taking the frequency-to-wavenumber ratio and its derivative gives

\[v_{\rm ph}={\omega\over\beta}={v\over\sqrt{1-(\omega_c/\omega)^2}},\]
\[v_g={d\omega\over d\beta}=v\sqrt{1-(\omega_c/\omega)^2},\]
\[v_{\rm ph}v_g=v^2 .\]

Phase fronts can move faster than the bulk wave speed along the guide. They are surfaces of equal phase and carry no independent message. A narrowband unattenuated envelope travels at the smaller group speed. An energy calculation provides a second route to the same quantity. Insert all three TE10 field components into \(\overline u=(\epsilon|\widetilde E|^2+\mu|\widetilde H|^2)/4\), integrate over the cross-section, and use \(\beta^2+(\pi/a)^2=\omega^2\epsilon\mu\). Electric and magnetic energies per length are each \(\epsilon ab|E_0|^2/8\). Dividing P by total energy per length yields

\[\beta/(\omega\epsilon\mu)=v_g.\]

Keeping only the transverse magnetic component would spoil the equality.

For an evacuated guide \(a=30.0\) mm, \(b=12.0\) mm, \(f_{c,10}=4.997\) GHz. At 8.00 GHz, \(\sqrt{1-(f_c/f)^2}=0.781\), \(v_g=2.34\times10^8\) m/s and guide wavelength \(2\pi/\beta=48.0\) mm. A 2 m section gives 8.54 ns group delay, compared with 6.67 ns in bulk vacuum. TE20 turns on at 9.99 GHz and TE01 at 12.49 GHz, so the chosen frequency is inside the single-propagating-mode band. With central electric peak 100 V/m, \(Z_{\rm TE}\simeq482\) Ω and \(P\simeq1.87\) mW. Knowing frequency is essential to infer power from the same central probe in another band.

Close the guide and quantize its longitudinal phase

Add perfect end walls at z=0 and z=L. Tangential E_y must vanish at each end, so superpose equal counterpropagating modes into \(\sin(p\pi z/L)\) with \(p=1,2,\ldots\) for this TE10 family. The resonance frequencies become

\[f_{10p}={v\over2}\sqrt{a^{-2}+(p/L)^2}.\]

The common estimate \(c/(2L)\) is the free spectral range for a nondispersive one-dimensional TEM cavity. It omits the transverse wavenumber in this example. For the guide above closed at \(L=60\) mm, \(f_{101}=5.59\) GHz and \(f_{102}=7.07\) GHz. Their separation is about 1.48 GHz, considerably smaller than the nominal 2.50 GHz TEM spacing. At sufficiently high longitudinal order the separation approaches \(v/(2L)\), though other transverse families can then populate the spectrum.

The mode's field has nodes and antinodes in two coordinates. A tiny probe on an electric node may leave a resonance undetected, and moving a lossy probe can also shift its frequency and damping. Two nearby spectral peaks could be adjacent p indices, two different transverse modes or a degeneracy split by manufacturing errors. Compare measured spatial patterns and polarization selection rules before indexing solely by a frequency spacing.

Derive amplitude decay, stored-energy decay and linewidth

In practice wall conduction, dielectric loss and deliberate port coupling all remove stored energy. If a lightly damped mode retains the same shape as it decays, energy obeys \(dU/dt=-\kappa U\). Then \(U=U_0e^{-\kappa t}\), field amplitude falls as \(e^{-\kappa t/2}\), and loaded quality factor is

\[Q_L=\omega_0/\kappa.\]

Energy lost per cycle is approximately \(2\pi U/Q_L\) for small fractional loss. The exact integrated energy lost over a cycle is \(U[1-e^{-2\pi/Q_L}]\). These expressions distinguish a rate in radians per second from linewidth in ordinary hertz.

Write a complex amplitude in a frame rotating at \(\omega_0\). Under a weak frequency-swept harmonic drive its steady amplitude is proportional to \([\,\kappa/2-i(\omega-\omega_0)\,]^{-1}\). The power response is a Lorentzian. Its half-maximum points have \(|\omega-\omega_0|=\kappa/2\), so the full power width is \(\kappa\) in angular frequency, or \(f_0/Q_L\) in hertz. A field-amplitude reading falls to \(1/\sqrt2\) at those same frequencies. Half the field magnitude corresponds to a different bandwidth.

Consider \(f_0=6.00\) GHz and \(Q_L=6000\). The power-line FWHM is 1.00 MHz, the energy e-folding time \(1/\kappa=159\) ns, and the field e-folding time 318 ns. Observe a field e-folding time of 159 ns instead, and the inferred Q would be 3000, even though the number printed on the oscilloscope is unchanged. Always determine whether an instrument's output voltage is proportional to field, instantaneous power or a filtered logarithm of either.

Separate a feed port from dissipative losses

Normalize a mode amplitude a so \(|a|^2=U\), and an incident port amplitude \(s_+\) so \(|s_+|^2=P_{\rm in}\). In a simple one-port cavity the internal loss rate \(\kappa_i\) and external escape rate \(\kappa_e\) add. A consistent choice of port phase gives

\[\dot a=[i\Delta-(\kappa_i+\kappa_e)/2]a+\sqrt{\kappa_e}s_+,\]
\[s_-=s_+-\sqrt{\kappa_e}a.\]

At steady on-resonance drive the reflected amplitude fraction is \((\kappa_i-\kappa_e)/(\kappa_i+\kappa_e)\). Exact cancellation at critical coupling is compatible with continued reflection when driving off resonance, and with finite resonant energy stored in the cavity. Once the drive is removed that energy decays through both channels.

With rates \(\kappa_i/(2\pi)=0.30\) MHz and \(\kappa_e/(2\pi)=0.70\) MHz, the resonant reflected power fraction is 0.16. The remaining 84% of the steady incoming power is dissipated internally in this one-port model. Interchanging the two rates preserves both the linewidth and reflected power at resonance but reverses the reflected phase. A calibrated coherent reflection or a second measurement after deliberately changing coupling can resolve this ambiguity.

Compare field and energy ring-down and linewidth at several loaded quality factors

Change guide width and follow cutoff and axial propagation

Use a small bead to map a cavity mode

A resonator offers a way to measure a field without placing a conventional field sensor at its maximum. Insert a small dielectric perturbation, record the change in resonance frequency, then scan its position. The derivation requires a closed, lossless cavity or a sufficiently high-Q nearly closed cavity for which one isolated mode is meaningful. Take fixed conducting walls, nondispersive permittivity and permeability, and a perturbation small enough to change the frequency and the shape smoothly. A nearby degeneracy requires a coupled-mode treatment.

In the source-free eigenproblem \(\nabla\times\mu^{-1}\nabla\times\mathbf E=\omega^2\epsilon\mathbf E\), multiply by the complex conjugate of the unperturbed mode and integrate over the volume. Subtract the conjugate unperturbed equation multiplied by the perturbed mode. Integration by parts transfers the double curl with no surface contribution at a fixed ideal conducting wall. Expand \(\omega^2\) and \(\epsilon+\delta\epsilon\) through first order. The unknown first-order change of mode shape cancels from the difference, leaving

\[\frac{\delta\omega}{\omega}=-\frac12\frac{\int\delta\epsilon(\mathbf r)|\mathbf E(\mathbf r)|^2\,dV}{\int\epsilon(\mathbf r)|\mathbf E(\mathbf r)|^2\,dV}.\]

A positive permittivity increment lowers the resonance frequency. The denominator is proportional to total electric energy for a nondispersive mode, and the fractional shift is the electric-energy overlap with the perturbation. The result describes a small perturbation of the permittivity distribution, not automatically a high-contrast conducting bead. A high-index sphere changes its own internal field even when it occupies a tiny volume; its electrostatic polarizability can then replace the simple weak-contrast volume approximation. The distinction matters if the shift is used for absolute calibration.

Suppose a weak dielectric insert raises local permittivity by 10.0 percent and covers a region containing 0.40 percent of the unperturbed electric energy. At 3.00 GHz the predicted fractional shift is \(-0.00020\), or \(-600\) kHz. Moving it to a position where the electric amplitude is half as large gives a 150 kHz shift for the same orientation, volume and local background. A map of resonance displacement measures squared field magnitude, so by itself it cannot determine the sign of an oscillating electric component. Two neighbouring antinodes separated by a nodal plane can produce nearly equal shifts with opposite electric phases.

A mode with loaded \(Q=3000\) at 3.00 GHz has a full linewidth of about 1.00 MHz. Its centre can still be fitted more accurately than the linewidth if signal-to-noise ratio and frequency stability are adequate. Record an unloaded baseline between bead positions and keep the probe coupling fixed. A systematic drift of 50 kHz is a small part of a linewidth but already one third of the expected shift at the lower-field position. If two modes draw close when the bead is moved, fitting one Lorentzian over their sum can imitate a position-dependent loss as well as a frequency shift.

A finite below-cutoff length is a boundary problem

A guide section whose infinite-guide propagation constant is imaginary does not simply have zero field. It supports decaying and growing spatial solutions. In a semi-infinite region an outgoing bounded solution picks the decaying branch. A finite narrowed section joined to a second propagating guide needs both branches to satisfy the two interfaces. This is the electromagnetic version of transmitting through a classically forbidden interval in a one-dimensional wave equation. No energy flows out of an isolated purely decaying transverse mode of the uniform lossless section, yet a properly driven combination can carry power through the interval.

Write a scalar model of one isolated mode as \(\psi''+k^2\psi=0\) in identical leads and \(\psi''-\kappa^2\psi=0\) in the central interval of length \(d\). Assume continuity of \(\psi\) and \(\psi'\) at both seams. This mimics a single matched constitutive parameter and deliberately neglects higher transverse modes excited at a real step. Propagation of the pair \((\psi,\psi')\) across the barrier uses hyperbolic functions. Matching it to an incident plus reflected wave on the left and one transmitted wave on the right gives

\[T=\left[1+\frac{(k^2+\kappa^2)^2}{4k^2\kappa^2}\sinh^2(\kappa d)\right]^{-1}.\]

At \(k=\kappa\) this simplifies to \(T=\mathrm{sech}^2(\kappa d)\). For \(\kappa=40\) per metre and lengths 25 and 50 mm, the transmitted powers are 0.420 and 0.0707 times incident. Doubling length does not square the transmission, because the reflected wave and the coupling at both interfaces matter. At large \(\kappa d\) an exponential remains, multiplied by a matching-dependent prefactor. Extrapolating a long-section straight line on a log-power plot to zero length should therefore not be interpreted as an additional physical loss in a zero-length guide.

For a real device use modal matching, or a numerical Maxwell solution retaining evanescent transverse modes at a discontinuity. Check convergence against the number of included modes at each step, not just the resolution along the uniform section. Measurements with several lengths can separate the uniform attenuation constant from entrance and exit effects. Measuring reflection as well as transmission discriminates a lossless cutoff barrier, where rejected energy returns to the source, from an absorber that dissipates it. Finally use a time-domain envelope narrow enough in frequency that the fraction above the cutoff is negligible. A small above-cutoff spectral tail can dominate a pulse recorded after a long barrier and give a misleading apparent decay length.

Infer a resonator timescale from its line

Change loss at a selected cavity mode and compare linewidth with energy decay. State whether each reported rate describes amplitude or energy.

Worked resonance problem · a square guide with a slight width error

A nominally square air-filled guide of side 20.0 mm supports two orthogonal fundamental patterns with identical cutoff in the ideal square section. The fabricated horizontal dimension is 20.10 mm; the other remains 20.00 mm. Estimate the two cutoffs and the polarisation beating length at 10.0 GHz. How could a single scalar power measurement miss the effect?

Follow the phases of the two modes

For the rectangular TE modes with one half-cycle across either side, the cutoffs are \(c/(2a)\) and \(c/(2b)\). These are 7.458 and 7.495 GHz, separated by about 37 MHz. At 10.0 GHz the longitudinal propagation constants are \(k_{zj}=(2\pi/c)\sqrt{f^2-f_{cj}^2}\). Their difference is about 0.88 per metre, corresponding to a full relative phase cycle over approximately 7.1 m. It takes only one quarter of this length to build a quarter-cycle retardance between equally excited components.

Near cutoff the propagation-constant sensitivity to a small width change is enhanced because the longitudinal wavenumber appears in the denominator of its derivative. Approaching the higher cutoff too closely also makes the interpretation vulnerable to wall loss, poorly matched launchers and higher-order evanescent contributions at the ends. Above both cutoffs in a sufficiently long uniform section, project the exit field on a pair of known orthogonal receiving patterns and measure their coherent phase difference. Two power readings along the eigenaxes remain unchanged in the lossless model even while a diagonal analyser shows oscillating power.

Rotating the input launcher onto one eigenpattern should suppress the beating, since no second component then accumulates a relative phase. Repeating the experiment at several frequencies tests the predicted dispersion of \(k_{z1}-k_{z2}\), distinguishing a distributed width mismatch from a nearly constant phase offset in two receiver cables. A slow twist of the guide can additionally couple the patterns instead of merely advancing their phases. In that situation first measure the full two-by-two complex transfer matrix; treating every disappearing component as attenuation would misidentify coherent mode conversion.

A vanishing resonance can be a coupling zero

A cavity spectrum measures modes through a particular feed and pickup. For a short aligned electric probe, coupling to a mode is proportional at leading order to the projection of the modal electric field onto the probe's current distribution. A probe at a nodal plane or oriented perpendicular to that field can therefore fail to display a well-defined cavity mode. Moving the receiver away from the node or rotating it can restore the spectral line without changing the cavity eigenfrequency.

As a quantitative illustration consider a mode whose electric field varies as a sine across the width. Move a small probe from one quarter of that width to one twelfth. The ratio of its squared coupling magnitudes is approximately 0.134. With an unchanged weak drive and an effectively nonloading pickup, the transmitted power in that mode can shrink by almost an order of magnitude. If the same port also substantially loads the cavity, its movement changes the linewidth and the resonant intracavity field as well.

A mapping experiment should record peak frequency, linewidth and integrated spectral response alongside peak power. A frequency shift with little change in linewidth supports a predominantly reactive perturbation, whereas linewidth changes signal modified damping or port coupling. A changing peak alone cannot distinguish a weak field region, a rotated polarisation and an altered loaded resonance. Combining two feed orientations with a weak scanning pickup supplies a more informative field map.

Tutorial · infer guide width from a delay without assuming a vacuum transit

A pulse at 9.00 GHz traverses 1.50 m of evacuated rectangular guide in 6.00 ns after cable delays are removed. Assume a narrowband TE10 packet with negligible loss and \(b=10.0\) mm. Infer its cutoff and guide width, check the next two candidate cutoffs and estimate its modal impedance.

Invert the dispersion and verify the mode assignment

The group speed is \(2.50\times10^8\) m/s, or 0.834 of c. Hence \(f_c=f\sqrt{1-(v_g/c)^2}\simeq4.97\) GHz and \(a=c/(2f_c)\simeq30.2\) mm. TE20 cuts on at about 9.94 GHz and TE01 at 15.0 GHz, both above the test. The TE impedance is \(Z_0/(v_g/c)\simeq452\) Ω. A broad pulse overlapping 9.94 GHz would require a mode-launch and dispersion analysis before interpreting one transit time with this inversion. Measuring delay at a second centre frequency tests the inferred cutoff without another width parameter.

Tutorial · separate an internal Q from a port Q

A one-port cavity has \(f_0=5.00\) GHz and measured power linewidth 0.80 MHz. Halving the port coupling rate with negligible resonance shift reduces linewidth to 0.60 MHz. Infer both initial rates in hertz, both quality factors, the initial resonant reflected fraction and the energy lifetime after the coupling change.

Combine the rate sums from both tests

Let \(g_i=\kappa_i/(2\pi)\) and \(g_e=\kappa_e/(2\pi)\). Solve \(g_i+g_e=0.80,\ g_i+g_e/2=0.60\) MHz to get \(g_e=g_i=0.40\) MHz. Both initial individual quality factors are \(5.00{\rm\,GHz}/0.40{\rm\,MHz}=12500\), and initial loaded Q is 6250. Initial reflection vanishes by critical coupling. After the change the resonant reflected amplitude is 1/3 and reflected power 1/9. The energy lifetime is

\[1/(2\pi\,0.60{\rm\,MHz})=265\,\mathrm{ns}.\]

This result relies on a fixed internal loss. A coupler adjustment that introduces dielectric loss would invalidate the two-equation inference.

David Staelin, MIT 6.013 · chapter 9 on waves guided by planar and rectangular structures

When a periodic dielectric has no propagating Bloch wave

Derive a band gap using two lossless transparent materials and distinguish evanescent Bloch propagation from absorption of optical power.

Construct a unit cell whose waves interfere

Stack two transparent, lossless, nonmagnetic dielectrics periodically in one dimension. Their refractive indices are \(n_1,n_2\), their physical thicknesses \(d_1,d_2\), and the period \(a=d_1+d_2\). Work at normal incidence, so polarisation directions are equivalent for isotropic layers. Each separate material admits a propagating wave at the chosen optical frequency, yet the periodic stack may not. The effect comes from coherent interface reflections, not from a negative refractive index or an absorptive constituent.

Describe the local field by its tangential electric and magnetic components. Propagation through one homogeneous layer connects them by a \(2\times2\) transfer matrix with diagonal \(\cos\phi_j\), off-diagonal terms proportional to \(iZ_j\sin\phi_j\) and \(i\sin\phi_j/Z_j\), where \(\phi_j=\omega n_jd_j/c\) and \(Z_j=Z_0/n_j\). Changing the chosen propagation direction or time convention may reverse the two imaginary signs together. The real trace and unit determinant of the cell matrix below are unaffected.

Read the dispersion relation from the trace

At an interface both tangential components are continuous in the absence of imposed sheet currents. Multiply the two propagation matrices to form one cell. Its determinant is one because each layer's determinant is

\[\cos^2\phi+\sin^2\phi=1.\]

Thus the two eigenvalues are reciprocal. For a Bloch mode they are \(e^{\pm i k_Ba}\) on a pass band. Taking half the trace gives

\[\cos(k_Ba)=\cos\phi_1\cos\phi_2-\frac12\left(\frac{n_1}{n_2}+\frac{n_2}{n_1}\right)\sin\phi_1\sin\phi_2 .\]

When the right side lies between −1 and 1 a real Bloch phase exists. If its magnitude exceeds one, a decaying and a growing Bloch factor replace a pair of unit-modulus factors. For a bounded excitation of a semi-infinite stack choose the decaying direction. The attenuation per cell is \(\operatorname{arcosh}|\operatorname{trace}(M)/2|\). A lossless semi-infinite crystal in a stop band reflects incident power. Spatial attenuation of a Bloch amplitude in this region is compatible with zero volumetric heat production.

Obtain a quantitative stop-band width

Choose \(n_1d_1=n_2d_2=\lambda_0/4\). Writing \(s=\omega/\omega_0\), both layer phases are \(\phi=\pi s/2\). At \(s=1\) the half trace is \(-\tfrac12(n_2/n_1+n_1/n_2)\). Recognising \(\cosh(\log r)=(r+r^{-1})/2\) gives centre attenuation \(|\log(n_2/n_1)|\) per cell. For \(n_1=1.5,n_2=2.0\) this is 0.2877, so a decaying eigencomponent has amplitude factor 0.75 per cell. This statement about an eigencomponent should not be confused with the exact transmittance of a specific finite stack, which also depends on entrance and exit impedances.

The first gap edges obey half trace −1. With \(\cos^2\phi=1-\sin^2\phi\), solve for the edge sine or cosine. The two edge phases are symmetric about \(\pi/2\) and satisfy

\[|\cos\phi|=|n_2-n_1|/(n_1+n_2).\]

Hence the fractional angular-frequency width is \((4/\pi)\arcsin(|n_2-n_1|/(n_1+n_2))\), about 0.183 for the example. The lowest gap width tends continuously to zero as index contrast vanishes. A gap in a plotted numerical spectrum at \(n_1=n_2\) would indicate an implementation or plotting problem.

Compare a frequency scan with a finite mirror

The graph plots half the transfer-matrix trace against normalised frequency and marks the admissible interval for a real Bloch phase. Change the index contrast first, keeping the layers quarter wave at the same reference frequency. The physical layer thickness adjusts in this family; it is a different experiment from changing a material while manufacturing all thicknesses fixed. Use the frequency control to read an attenuation exponent at the centre and just outside the gap.

At low frequency a wavelength spans many cells and a homogenised description can predict the long-wave speed. At the first gap the field changes phase by order one across a cell, exactly where the homogenisation scale separation fails. Conversely, an electromagnetic calculation showing multiple bands at very low frequency should be checked against a uniform-medium or long-wavelength effective-index limit. Compare a finite stack's reflection with the Bragg-mirror experiment. The bulk trace determines whether a propagating state can exist. A finite sample adds interference between boundaries and possible surface or defect effects.

Tutorial

If the two refractive indices become equal, simplify the trace formula for arbitrary thicknesses.

Work through the solution

The impedance factor becomes one, so the half trace is \(\cos\phi_1\cos\phi_2-\sin\phi_1\sin\phi_2=\cos(\phi_1+\phi_2)\). It never exceeds unit magnitude. Labelling a uniform medium by an artificial period folds the dispersion into zones but does not create a physical gap.

At the central quarter-wave frequency for index ratio 2, how many periods reduce a decaying Bloch component's amplitude by a factor of 100?

Work through the solution

The amplitude factor per cell is

\[e^{-\log2}=1/2.\]

Require \(2^{-N}\le0.01\), giving \(N\ge7\). A prediction for transmitted optical power also needs termination and impedance matching.

A measured stack exhibits both a transmission minimum and measurable heating. Can the minimum be attributed entirely to a band gap?

Work through the solution

A lossless band gap can reflect power without heating. Measure reflected and transmitted flux under consistent normalisation, then infer absorption from \(1-R-T\) after accounting for diffuse scattering and other exit channels. The bulk stop-band model and material absorption can coexist.

Compare with band calculations

MIT's mathematical nanophotonics course computes full periodic Maxwell modes. The one-dimensional trace above is a small benchmark with known pass and stop boundaries that a numerical eigenproblem should reproduce.

Why rotating a layered dielectric changes a capacitance measurement

Derive the two principal permittivities of a fine laminate, rotate the constitutive tensor and distinguish the applied electrode condition from an assumed field direction.

Compare the same material in two orientations

Build a specimen by repeating layers with scalar permittivities \(\epsilon_1,\epsilon_2>0\), occupying fractions \(f\) and \(1-f\). The period is much smaller than both the specimen scale and the spatial variation of the applied field. Suppose both materials are linear, free of mobile charge and effectively lossless in the measurement band. An observer using a large capacitor wants one law relating averaged displacement and electric field. A scalar average cannot describe both arrangements of the same layers relative to the plates.

Place the field tangential to all internal interfaces first. A narrow rectangular electrostatic loop straddling an interface gives continuity of tangential \(E\). Both layers see the same tangential field, but their displacements differ in proportion to permittivity. Averaging gives

\[\overline D_t=[f\epsilon_1+(1-f)\epsilon_2]\overline E_t.\]

The tangent-direction effective permittivity is an arithmetic mean. This is a parallel connection of capacitances at shared voltage in the special capacitor geometry.

Apply a purely normal displacement instead. No free charge lies at the internal interfaces, so their normal displacement is continuous. Normal fields differ as \(E_i=D_n/\epsilon_i\). Averaging the voltage drops gives

\[\overline E_n=[f/\epsilon_1+(1-f)/\epsilon_2]\overline D_n,\]

with a harmonic-mean effective permittivity. The local continuity condition changes which field is shared between constituents and thereby changes the relevant averaging operation.

Check the amount of anisotropy from field energy

For \(\epsilon_1=2\epsilon_0,\epsilon_2=10\epsilon_0\) at equal fractions,

\[\epsilon_t=6\epsilon_0,\]
\[\epsilon_n=(10/3)\epsilon_0.\]

The arithmetic-to-harmonic ratio is 1.8. A constituent does not need to be crystalline or anisotropic for the composite to show distinct principal responses. The geometry of the internal boundaries is enough.

Average the energy density for the tangential experiment,

\[u=f\epsilon_1E_t^2/2+(1-f)\epsilon_2E_t^2/2=\epsilon_t E_t^2/2.\]

For the normal experiment,

\[u=D_n^2[f/\epsilon_1+(1-f)/\epsilon_2]/2=D_n^2/(2\epsilon_n).\]

These expressions supply a check independent of the capacitor-circuit analogy and identify which energy should be used when field or free charge is controlled. Energy positivity follows directly from the positive constituent permittivities. It does not require guessing an effective law from the largest measured component.

Rotate the law, then specify what the electrodes control

Use principal axes \(\hat n,\hat t\) and suppose a macro-field makes angle \(\theta\) to the layer normal. If \(\overline{\mathbf E}=E(\cos\theta\,\hat n+\sin\theta\,\hat t)\), then \(\overline{\mathbf D}=E(\epsilon_n\cos\theta\,\hat n+\epsilon_t\sin\theta\,\hat t)\). Project along the imposed field and divide by \(E\):

\[\epsilon_E(\theta)=\epsilon_n\cos^2\theta+\epsilon_t\sin^2\theta .\]

The perpendicular displacement is \(E(\epsilon_t-\epsilon_n)\sin\theta\cos\theta\). It is generally nonzero. A device that instead fixes the direction of averaged displacement while allowing a transverse field measures \(\epsilon_D(\theta)=[\cos^2\theta/\epsilon_n+\sin^2\theta/\epsilon_t]^{-1}\). These two directional responses correspond to different constraints. They agree at principal axes and for isotropic material. A pair of unspecified “angled capacitor” measurements cannot be interpreted uniquely without describing the contacts and edge conditions.

At 45° in the example, the field-controlled projection gives about \(4.667\epsilon_0\), while the displacement-controlled projection gives \(4.286\epsilon_0\). These are both legitimate scalar ratios from one symmetric positive-definite tensor. Neither supplies a universal scalar permittivity for the rotated material. The complete vector response also predicts displacement tilt and field energy for any orientation.

Test the measurement against the unit-cell model

Change the volume fraction while keeping the constituent values fixed. At a pure phase all orientations and both control conditions must collapse to a single value. At intermediate fractions, find the angle where the transverse component would be largest. It occurs where \(|\sin\theta\cos\theta|\) is largest, but its magnitude also reflects the material contrast. Now reduce the contrast mentally to one and predict all curves without recomputing a single cell.

A numerical field model offers an independent homogenisation experiment. Use periodic tiling in the material directions and impose a macroscopic voltage difference plus periodic fluctuations on opposite faces. For a unit imposed field along each coordinate direction, average the resulting displacement over the cell. The resulting vectors supply the tensor columns. A grounded box on every side is a different boundary problem and can suppress the tangential response. Increase the number of material periods at fixed specimen scale and refine the individual period separately. These two limits test homogenisation and numerical representation, respectively.

How far can the effective law travel?

Electrostatic homogenisation assumes the cell fields respond quasistatically. In a wave experiment near the Bragg gap, phase changes substantially across one period and a local constant tensor is inadequate. A finely layered capacitor and a dielectric mirror can be made from the same constituents while requiring different models at different frequencies. Test the Bloch spectrum to identify the regime where layering begins selecting propagation bands. A low-frequency effective index alone cannot predict that gap.

Large spatial contrast also places a practical demand on mesh and interface handling. A normal gradient can jump strongly even when potential and displacement are continuous. A smooth-looking interpolated voltage surface is weak evidence for an accurate energy density. Compare constituent fields, total flux and energy consistency before accepting the extracted effective tensor.

Tutorial

Show that \(\epsilon_t-\epsilon_n\) is nonnegative for every positive pair of constituents without appealing to a named mean inequality.

Work through the solution

Put both terms over the positive denominator \(f\epsilon_2+(1-f)\epsilon_1\). The numerator after cancellation is \(f(1-f)(\epsilon_1-\epsilon_2)^2\), so the difference is nonnegative and vanishes for identical materials or a pure phase.

Equal fractions give measured relative values 6 tangentially and \(10/3\) normally. Can you infer both constituents if the laminate assumptions hold?

Work through the solution

Their sum is 12. The harmonic mean is \(2ab/(a+b)=10/3\), giving product 20. The positive roots of \(x^2-12x+20=0\) are 2 and 10. The data do not identify which label belongs to which phase without another observation.

Why can a constituent occupy very little volume yet strongly affect the normal response?

Work through the solution

Every normal field line in this lamination crosses each layer. The inverse response weights \(f/\epsilon\); even a thin, low-permittivity layer can contribute a large voltage drop. A field along the layers distributes displacement differently and may be much less sensitive to that same phase.

How a magnetic field rotates the polarisation of transmitted light

Resolve a linearly polarised wave into circular eigenmodes, infer a refractive-index difference from an analyser and distinguish nonreciprocal rotation from a simple change of reference axes.

Derive rotation from propagation rather than drawing an arrow

Let monochromatic light propagate along \(+z\) through a transparent magneto-optic sample, with an externally prepared axial magnetic field. Define fixed laboratory vectors \(\mathbf e_\pm=(\hat x\pm i\hat y)/\sqrt2\) and use phasors \(e^{i(kz-\omega t)}\). These definitions specify the handedness algebraically. Calling a vector simply “right circular” without stating the viewing and time conventions can reverse a reported rotation sign.

An input linearly polarised in \(x\) is \((\mathbf e_++\mathbf e_-)/\sqrt2\). Suppose the medium supports wave numbers \(k_\pm=2\pi n_\pm/\lambda_0\) for the two bases, with negligible absorption. After a distance \(L\), factor out the common phase \(e^{i(k_++k_-)L/2}\). The remaining Cartesian phasor is \(\hat x\cos\Delta-\hat y\sin\Delta\), where \(\Delta=(k_+-k_-)L/2\). Thus the polarisation angle in the fixed \(x,y\) plane is

\[\theta=\frac{\pi L}{\lambda_0}(n_- - n_+).\]

Equal transmissions of the two components preserve a linearly polarised output. Unequal absorption makes the circular amplitudes unequal and generally produces an ellipse. Rotating a linear analyser then finds a finite minimum, even for a perfectly coherent field. Residual intensity at the nominal extinction angle can also arise from stray light or imperfect polariser extinction, which must be measured independently.

Derive a magneto-optic eigenbasis

For axial magnetisation, a simple lossless transverse relative-permittivity block is \(\left(\begin{smallmatrix}\epsilon&i g\\-i g&\epsilon\end{smallmatrix}\right)\) with real \(g\) at the frequency of observation. Acting on \((1,i)\) gives \((\epsilon-g)(1,i)\); acting on \((1,-i)\) gives \((\epsilon+g)(1,-i)\). For relative permeability near one, \(n_+^2=\epsilon-g\), \(n_-^2=\epsilon+g\). At small \(g\) their difference \(n_- - n_+\simeq g/\sqrt\epsilon\). Reversing magnetisation reverses the sign of the off-diagonal coefficient and interchanges the two eigenvalues. Both the existence of circular modes and the sign-reversal test now follow from a constitutive model.

If \(n_--n_+\) is proportional to magnetic field over a specified range, write \(\theta=VBL\), with Verdet constant \(V\) in rad/(T m). This is a measurable material and wavelength dependent coefficient. It is not determined by the mean refractive index alone. A strong nearby absorption line can give substantial frequency dependence and dichroism, invalidating a lossless narrow-band extrapolation.

Work through an analyser calibration

For \(\lambda_0=600\) nm, \(L=0.20\) mm and measured index difference \(5.0\times10^{-4}\), the rotation is \(\pi(2.0\times10^{-4})(5.0\times10^{-4})/(6.0\times10^{-7})=\pi/6\), or 30°. An ideal analyser at angle \(\alpha\) transmits \(I/I_\mathrm{in}=\cos^2(\alpha-\theta)\). Its maxima occur at \(30^\circ\) and \(210^\circ\); an intensity measurement determines a linear polarisation angle modulo 180°. For a sample thick enough to rotate several half turns, an intensity maximum alone cannot give an unwrapped \(\theta\). Vary field or path length continuously from a known reference.

If the applied field is independently 0.40 T in that example, \(V=\theta/(BL)\simeq6.54\times10^3\) rad/(T m). The arithmetic is dimensionally correct, but the large value warrants a physical check of thickness, field calibration, units and material spectrum before reporting it as an ordinary glass coefficient. Degrees substituted for radians would make the inferred material coefficient too large by \(180/\pi\).

Use field reversal to reject alignment errors

The experiment shows the predicted analyser traces for opposite index splitting, with the same input polariser. Increase sample thickness to see why tracking the maximum by one measurement can select the wrong branch. Reversing the splitting reverses the tilt in fixed laboratory axes. A fixed analyser offset shifts both inferred angles equally and cancels in half their difference, provided the branch has been unwrapped consistently.

For small rotation, an analyser exactly at a crossed position transmits intensity proportional to \(\theta^2\). Its response has no sign sensitivity close to zero. Set the analyser at 45° instead:

\[\cos^2(\pi/4-\theta)=[1+\sin(2\theta)]/2\simeq1/2+\theta.\]

The difference between fields \(+B\) and \(-B\) then measures a signed signal linear in small rotation. This trades extinction of the background for sensitivity to sign. Balance the two orthogonal analyser outputs if source intensity fluctuates appreciably during a sweep.

Ask what happens on a return pass

For the ideal Faraday medium at fixed magnetisation, the circular eigenmodes relative to a fixed laboratory basis are determined by its transverse material tensor. On propagation back through the sample, the accumulated positive propagation path again distinguishes the same laboratory circular basis after accounting for the reflection boundary. With a suitable simple mirror at normal incidence, the resulting material rotation doubles on a round trip in fixed transverse coordinates. In a reciprocal optically active material, the eigenvalue assignment with respect to the laboratory basis reverses on reversing propagation, and the single-pass rotation cancels on the ideal return. Write both transformations in one fixed basis before comparing signs.

A real double-pass setup includes mirror phase shifts, stress birefringence of windows and possible ellipticity. Reversing magnetic field, removing the sample and recording both analyser quadratures provide separate checks. A nonzero rotation in one transmitted beam proves only that its polarisation changed; establishing nonreciprocity requires comparing a reversed propagation experiment with a stated polarisation convention.

Tutorial

Two analyser maxima occur at 47° and 39° for opposite weak fields. If the response is linear and the same branch is tracked, what field-induced rotation and static offset do they imply?

Work through the solution

Half the difference gives 4 degrees of signed rotation for the first field relative to zero. The mean is 43 degrees, the combined input polarisation and analyser zero. Conversion to a Verdet constant additionally needs the applied field and path length.

In the 600 nm example, what thickness uncertainty corresponds to 1 degree of rotation uncertainty at fixed index difference?

Work through the solution

Rotation is proportional to thickness. Relative uncertainty \(1/30\) therefore gives about \(0.20/30=0.0067\) mm, or 6.7 μm. Uncertainty in wavelength or field would add additional contributions.

An ideal analyser gives a minimum 4% of its maximum. Can this be explained solely by a rotation of an ideal linearly polarised monochromatic input in a lossless circularly birefringent sample?

Work through the solution

Pure rotation preserves a linear state, so an ideal analyser should extinguish it completely. Differential loss, ellipticity, depolarisation, finite bandwidth or a detector background are possible alternatives. Use circular-analysis or full Stokes measurements and an empty-path baseline to distinguish them.

Compare with a full polarisation measurement

Use the Stokes reconstruction experiment to determine which intensities reveal a circular component. A fitted linear rotation alone cannot measure that missing component.

What a detector samples

Compare radiation, scattering and the measured diffraction pattern. Examine how aperture sampling, transfer calibration and finite coherence alter the observable.

  1. Radiating multipoles and what a detector actually integrates
  2. Scattering, extinction and the phase of the forward wave
  3. Diffraction from the near field to the focal plane
  4. Measure the phase speed of a numerical electromagnetic wave
  5. Separate diffraction from a finite observation window
  6. Estimate a cavity linewidth from a finite, biased record
  7. Reconstructing a partially polarised electromagnetic wave
  8. Two polarisations moving through a uniaxial crystal
  9. What a momentum eigenstate means in a finite experiment
  10. From a finite pulse to a continuum transition rate
  11. Which part of a Bell correlation survives imperfect state preparation?
  12. Recover a transition frequency from two separated pulses

Radiating multipoles and what a detector actually integrates

A small oscillating source looks point-like from a distant detector, yet its angular pattern reveals its structure. Derive electric and magnetic dipole radiation from a conserved current, identify what survives when electric dipoles cancel, and turn a detector aperture into a calibrated estimate of total power.

Name the small parameters before discarding a part of the field

Let d be the characteristic source size, r the source-to-detector distance, and \(k=\omega/c\). The condition \(d/r\ll1\) permits geometric expansions of the radial amplitude. The condition \(kr\gg1\) selects the radiation field over induction and quasistatic fields. The condition \(kd\ll1\) permits a multipole expansion of the source's directional phase. These inequalities concern different pairs of lengths. A source can be electrically small while a probe sits in its near field. A large optical aperture can be many wavelengths wide while its far field is measurable at a sufficiently large r, though it then requires many multipoles or a full Fourier integral.

For harmonic localized sources in vacuum the outgoing far-zone vector potential is proportional to \(\mathbf I(\mathbf n)=\int\widetilde{\mathbf J}(\mathbf r')e^{-ik\mathbf n\cdot\mathbf r'}d^3r'\). Differentiating the rapidly varying \(e^{ikr}/r\) factor gives the magnetic field; using the radiation plane-wave relationship gives the electric field. This removes the component of \(\mathbf I\) parallel to the observation direction:

\[\widetilde{\mathbf E}_{\rm rad}={i\omega\mu_0e^{ikr}\over4\pi r}\,[\mathbf I-\mathbf n(\mathbf n\cdot\mathbf I)],\]
\[\widetilde{\mathbf B}_{\rm rad}={1\over c}\mathbf n\times\widetilde{\mathbf E}_{\rm rad}.\]

The transverse projection is essential. It forces zero electric-dipole radiation along the dipole axis. Treating the current integral as an already transverse scalar misses this geometrical zero and produces the wrong total power.

Eliminate an integrated current with charge conservation

The electric dipole moment is

\[\mathbf p=\int\mathbf r'\rho\,d^3r'.\]

Differentiate this definition and use \(\dot\rho=-\nabla'\cdot\mathbf J\). For component j, integration by parts changes \(-\int x'_j\partial'_lJ_l\) into \(\int J_j\), since the surface term vanishes outside a localized current. Thus \(\int\widetilde{\mathbf J}=-i\omega\widetilde{\mathbf p}\). For \(kd\ll1\) the leading term of the phase expansion is one. Inserting it gives

\[\widetilde{\mathbf E}_p={k^2e^{ikr}\over4\pi\epsilon_0r}[\mathbf p-\mathbf n(\mathbf n\cdot\mathbf p)],\]
\[{d\overline P\over d\Omega}={\omega^4|\mathbf n\times\mathbf p|^2\over32\pi^2\epsilon_0c^3}.\]

The phasor p is a peak moment. For a linearly oscillating real-axis dipole along z the intensity follows \(\sin^2\theta\), independent of azimuth. Integrating \(\sin^2\theta\sin\theta\,d\theta d\phi\) gives \(8\pi/3\). Hence the cycle-averaged total is \(\overline P=\omega^4|\mathbf p|^2/(12\pi\epsilon_0c^3)\). A complex vector p describing an elliptical source is allowed in the vector formula. With equal orthogonal components in temporal quadrature, radiation along the normal to their plane is circularly polarized and there is no direction parallel to both components at once.

Consider an effective moment \(p_0=1.0\times10^{-12}\) C m at 100 MHz. A vacuum far-field receiver at 10 m on the equator sees peak \(E_0=k^2p_0/(4\pi\epsilon_0r)=3.95\) mV/m. Mean flux is \(E_0^2/(2Z_0)=20.7\) nW/m². Total power is \((8\pi/3)r^2 S_{\rm eq}=17.4\) μW. At the same distance but a 30° polar angle the field peak halves and flux falls to a quarter. Increasing frequency while holding moment fixed raises power as the fourth power. Maintaining that same moment with a specified driven current introduces its own frequency dependence, so a frequency sweep must state the held source variable.

Recover the magnetic dipole from the antisymmetric current moment

Expand the phase as \(1-ik n_j x'_j+\cdots\). The first directional correction involves \(M_{ij}=\int x'_j J_i\,d^3r'\). Its symmetric and antisymmetric parts have distinct origins. Define \(\mathbf m=\tfrac12\int\mathbf r'\times\mathbf J\,d^3r'\). Then the antisymmetric contraction with n gives a current contribution \(ik\mathbf n\times\mathbf m\) for the index convention above. Substituting into the far-field electric expression yields

\[\widetilde{\mathbf E}_m=-{Z_0 k^2 e^{ikr}\over4\pi r}\mathbf n\times\mathbf m,\]
\[\overline P_m={\mu_0\omega^4|\mathbf m|^2\over12\pi c^3}.\]

A small planar current loop has \(\mathbf m=I\,\mathbf A\) with oriented area vector. For a loop in the xy plane its magnetic-dipole intensity has the same \(\sin^2\theta\) dependence as a z electric dipole, while its electric polarization is azimuthal instead of meridional. An intensity detector without polarization analysis can therefore confuse two fundamentally different sources. A rotating linear analyser placed at the equator can distinguish them even if each delivers the same incident power.

For a loop of radius 10 mm carrying a 10 mA peak sinusoidal current at 100 MHz, \(m_0=3.14\times10^{-6}\) A m² and the equivalent effective electric-moment magnitude for equal power is \(m_0/c=1.05\times10^{-14}\) C m. Its power is about \(17.4\,\mu{\rm W}(0.0105)^2=1.91\) nW. The current and geometry are assumed uniform around the loop. Larger loops require retaining retardation along the current path and a feed model before scaling this result.

Keep the symmetric part when the electric dipole vanishes

Define \(D_{ij}=\int \rho x'_ix'_j\,d^3r'\). One integration by parts gives

\[\dot D_{ij}=\int(x'_iJ_j+x'_jJ_i)d^3r'.\]

Therefore \(M_{(ij)}=-i\omega D_{ij}/2\) for harmonic sources. Split D into trace and traceless parts, defining \(Q_{ij}=3D_{ij}-\delta_{ij}\operatorname{tr}D\). The trace contribution after contraction is parallel to n and vanishes under transverse projection. Relative to the electric dipole field the effective transverse source is consequently

\[\widetilde{\mathbf E}_{p,Q}={k^2e^{ikr}\over4\pi\epsilon_0 r}\,\mathsf P_\perp\!\left[\mathbf p-{ik\over6}Q\mathbf n\right],\]
\[\mathsf P_\perp\mathbf v=\mathbf v-\mathbf n(\mathbf n\cdot\mathbf v).\]

This coefficient belongs to the stated quadrupole convention. Changing the factor three in Q changes the prefactor in the radiation field. Comparing numerical tensors from different sources therefore requires checking their definitions. Electric quadrupole and magnetic dipole fields both arise at the same first correction to a general localized current. One cannot always describe a source whose electric dipole vanishes as purely quadrupolar without examining the current's antisymmetric moment.

A transparent demonstration uses two opposite, equal z-directed electric dipoles separated along z by distance d. Their individual small-source patterns are proportional to \(\sin\theta\). The pair's far-field phase sum is \(-2i\sin(kd\cos\theta/2)\) up to an overall phase. When \(kd\ll1\) the field pattern is proportional to \(\sin\theta\cos\theta\), with zeros on the axis and equator and maxima at 45° and 135°. Expansion of the exact array factor gives a controlled test of the approximation. At \(kd=0.4\), \(\theta=45^\circ\), the argument of the sine is 0.1414. Replacing the sine by its argument overestimates amplitude there by about \(0.1414^2/6=0.33\%\). A small amplitude imbalance in the opposite dipoles can reintroduce an electric-dipole contribution even where the ideal quadrupole vanishes.

Change the symmetry of a dipole pair and test which angular nulls survive

Integrate over the detector aperture

A detector collecting directions within a cone normally measures an integral of \(dP/d\Omega\) times throughput and polarization acceptance. For a z electric dipole and a complete azimuthal cone of half-angle \(\theta_a\) centred on +z, the fraction is

\[f_{\rm pole}={\int_0^{\theta_a}\sin^3\theta\,d\theta\over\int_0^\pi\sin^3\theta\,d\theta}={2-3\cos\theta_a+\cos^3\theta_a\over4}.\]

For small \(\theta_a\) expand the integrand rather than subtracting nearly equal cosines in floating point: \(f_{\rm pole}\simeq3\theta_a^4/16\). Although a true axial ray carries no power, a finite cone collects a small positive flux varying as the fourth power of its opening angle. An isotropic-emission approximation would instead scale as \(\theta_a^2/4\), badly overestimating the near-null signal. An equatorial belt between \(\theta=\pi/2-\delta\) and \(\pi/2+\delta\), spanning all azimuths, captures fraction \((3\sin\delta-\sin^3\delta)/2\). For \(\delta=10^\circ\) this is 0.258, even though the belt covers only 0.174 of the full solid angle.

To convert a small planar detector into solid angle, include its projected area. For a detector of area \(A_d=1.0\) cm² normal to the line of sight at 2.00 m, \(\Delta\Omega\simeq A_d/r^2=2.5\times10^{-5}\) sr. At an equatorial maximum the normalized dipole density is \(3/(8\pi)\) per steradian, giving a collected fraction \(2.98\times10^{-6}\). Rotating its face 60° to the line of sight halves this fraction before considering polarization-sensitive throughput. An extrapolation from a small aperture to total emission is therefore a model-based estimate, whose validity can be assessed with readings at additional angles.

Separate geometrical zeros from coherence and background

Suppose equal geometry and detectors at polar angles 90°, 45° and 0° return powers 100, 50 and 5 in arbitrary units. An ideal point dipole with no offset would suggest 100, 50 and zero. Fitting a constant isotropic additive background using the axial reading leaves 95, 45 and zero. A pure dipole would predict 47.5 at 45° after subtraction. The discrepancy is small but informative if calibration uncertainty is smaller. Check finite aperture before interpreting the axial excess as a second emitter; make the aperture twice as narrow and see whether its captured fraction near the null falls by roughly sixteen, as for an ideal axial dipole cone.

If two excited source moments are coherent, add their complex fields before squaring. Their cross term can create a fore-aft asymmetry that disappears upon incoherent averaging. If their relative phase changes randomly over the integration window, add the angle-dependent intensities instead. A single angular sweep measures some combinations of magnitudes and relative phases and leaves others degenerate. Repeating with an analyser or a known phase reference helps distinguish a weak quadrupole contribution from an independent weak background. A total-power reading alone discards even more directional information.

Compare radiated power and angular dependence against a dipole calculation

Directionality from coherent electric and magnetic moments

A compact source can have two comparable leading moments of different type. This can happen if a resonant dielectric particle supports electric and magnetic responses at the same optical frequency. The long-wavelength multipole expansion still applies to the exterior observation, but symmetry or resonance can change the relative magnitudes of the moments. Add the electric fields before calculating power whenever the moments are coherently driven. Adding two separately calculated angular powers would erase a measurable directional effect.

Take an electric moment \(p\mathbf e_x\) and a magnetic moment \(m\mathbf e_y\), both complex peak amplitudes with the same time convention. Their leading radiation fields share the common factor \(k^2e^{ikr}/(4\pi\epsilon_0r)\). The electric vector is \(\mathbf p-\mathbf n(\mathbf n\cdot\mathbf p)\). The magnetic contribution in these units is \(-\mathbf n\times\mathbf m/c\). Thus in the \(+z\) and \(-z\) directions their electric polarisations coincide with \(x\), but one magnetic contribution changes sign. After removal of the common amplitude their intensities are proportional to

\[I_+=|p+m/c|^2,\]
\[I_-=|p-m/c|^2,\]
\[\frac{I_+-I_-}{I_++I_-}=\frac{2\operatorname{Re}(p^*m/c)}{|p|^2+|m/c|^2}.\]

If \(m/c=p\), the intensity vanishes exactly in the backward direction. A quadrature phase between equal magnitudes removes the forward–backward difference, even though both moments radiate. A pair of intensity measurements therefore constrains a real cross term but does not determine a unique pair of complex moments. Rotating analysers and adding another angular direction can supply additional independent constraints.

To understand the full angular pattern, sum the squared magnitudes of the two vector contributions for an arbitrary direction. The separate terms are \(|p|^2(1-n_x^2)\) and \(|m/c|^2(1-n_y^2)\); their cross term is \(2 n_z\operatorname{Re}(p^*m/c)\). For the equal in-phase case the sum reduces to \(|p|^2(1+\cos\theta)^2\). Its integral over the sphere is \(16\pi|p|^2/3\), twice the integral for one electric dipole alone at this amplitude. The cross term integrates to zero because it reverses sign between opposite hemispheres. Directional suppression redistributes existing radiation while leaving the sphere-integrated powers of these two orthogonal multipole types additive.

The mean angular intensity is proportional to \(4|p|^2/3\), and the forward value to \(4|p|^2\). The corresponding directivity is three. The backward hemisphere still contains radiation even when its axial intensity is exactly zero. Integrating \((1+u)^2\) from \(u=-1\) to 0 and dividing by the integral from \(-1\) to 1 gives a fraction \(1/8\). A detector measuring integrated backward hemispherical power would report a clear finite signal. Two teams reporting an axial null and one eighth backward power are describing consistent observations if their angular acceptances differ.

The extinction of a null is exceptionally sensitive to field errors

Set \(m/(cp)=(1+\epsilon)e^{i\varphi}\), with real small amplitude imbalance \(\epsilon\) and phase error \(\varphi\) in radians. Expanding the backward intensity to the first nonzero order gives

\[I_-/|p|^2\simeq\epsilon^2+\varphi^2;\]

the forward intensity is about \(4|p|^2\). Misalignment, background scattering and angular acceptance can also fill the nominal null. The ratio alone cannot identify an electric–magnetic amplitude mismatch unless phase and background are independently known.

A 5.0 percent amplitude error together with a five-degree phase error gives a leading estimate \(I_-/I_+\simeq0.00253\). Using the exact formula gives about 0.00250. With 100,000 forward counts in matched exposures a perfectly calibrated backward detector would register about 250 signal counts. A background of 200 counts is comparable to this signal, and subtracting it adds uncertainty from the background exposure. Doubling the integration time does not remove an incorrectly modelled constant fraction of forward stray light reaching the backward detector.

Finite acceptance near an exact null has a different scaling. In the ideal balanced case write \(\theta=\pi-\delta\). The intensity \((1-\cos\delta)^2\) grows as \(\delta^4/4\). Integrated over a cone of half-angle \(\alpha\) it scales as \(\alpha^6\), because \(d\Omega\) contributes a further factor of \(\delta\). A small constant background integrated over the same cone instead scales as \(\alpha^2\). Measuring with several aperture stops can distinguish these trends only if the instrument's point-spread function and angular centring are known. For a simple electric dipole aligned with the viewing direction, the zero is quadratic in angle, giving yet another scaling.

A set of checks can distinguish a physical interference null from an insensitive receiver. Rotate the source by half a turn about the \(y\) axis so that its electric moment changes sign but its magnetic moment does not. The predicted dark direction should reverse. Reverse one measurement cable's reference phase in a coherent receiver and verify that the reported phase changes while intensity does not. Use an independent isotropic calibration source or a known dipole orientation to calibrate gain in both directions. Finally scan frequency through the resonances that create the two moments. The null should follow the relative amplitude and phase inferred from independently measured spectral responses, not just one accidentally quiet detector channel.

Cancel the leading dipole contribution

Change the separation or relative phase of the source elements and locate directions in which the leading radiation vanishes.

Worked angular problem · fit an axis tilt from two detectors

A linearly oscillating electric dipole intended to lie along \(z\) is tilted by a small unknown angle \(\epsilon\) toward \(+x\). Matched detectors in the \(xz\) plane are placed at \(+45^\circ\) and \(-45^\circ\) relative to \(z\). Their background-subtracted counts are 4200 and 5800 in equal exposures. Infer the tilt and its approximate counting uncertainty. Would reversing the electric dipole's oscillation phase change the answer?

Keep the two detector directions separate

With positive angles toward \(+x\), the expected intensities vary as \(\sin^2(\pi/4-\epsilon)\) and \(\sin^2(\pi/4+\epsilon)\). Their sum is independent of tilt, and the signed difference divided by their sum is \(\sin(2\epsilon)\) when the difference is defined as \(I_- - I_+\). Its measured value is 0.160. The small solution is

\[\epsilon=\arcsin(0.160)/2=4.60^\circ.\]

Additional mathematical solutions are excluded by knowing the source is close to the desired initial axis.

Treat the counts as independent Poisson measurements with background uncertainties negligible for this calculation. Condition on their total of ten thousand. The normalised difference has estimated standard error \(\sqrt{(1-0.160^2)/10000}=0.00987\). Propagating through the inverse sine gives a tilt error of about 0.0050 radians or 0.29 degrees. A relative detector-gain error can imitate part of this difference. Swap the detectors physically while preserving source orientation or interchange the source tilt to separate a fixed gain bias.

Reversing the dipole phase multiplies the entire electric field by minus one, leaving both intensities unchanged. A phase-sensitive receiver with a common reference could detect the reversal. A finite aperture averages a range of angles, reducing the sensitivity if the apertures are wide. Integrate the angular predictions across the measured fields of view before applying the point-detector formula to a precision tilt.

A translated expansion can mix multipole labels

The exact far field is independent of where the expansion origin is drawn. Individual moments need not be. A translation of the source origin by a vector changes the electric dipole by the total source charge times that vector, with sign depending on the translation convention. For an electrically neutral compact source the dipole is therefore origin independent. A corresponding expansion of the quadrupole contains products of the translation with the dipole as well as the monopole. If both lower moments vanish, the first surviving electric quadrupole is likewise robust under a shift.

In a directional Fourier integral, changing the origin also changes the external phase that multiplies the expanded moments. At a fixed observation direction this common phase has no effect on intensity, but at a given truncation order its series must be kept consistently when comparing complex amplitudes. An origin-dependent angular intensity at the nominal retained order is a warning that a translated lower-order contribution or a same-order magnetic term may have been dropped.

A numerical check translates the integration grid by a known small vector while preserving the physical source and detector positions. Recompute both the unexpanded far-field integral and its truncated multipole prediction. The exact physical comparison should agree after phase referencing. The discrepancy between a leading-order expansion and the exact result should scale with the neglected power of source size over wavelength. This test probes moments, phase conventions and coordinate bookkeeping with one calculation.

Tutorial · infer a dipole moment and estimate detector uncertainty

A calibrated equatorial probe at 5.0 m observes a 300 MHz linearly oscillating dipole with RMS electric amplitude 2.00 mV/m. Determine peak moment and total emitted power. The receiver angle is uncertain by ±5° around the equator. Estimate the peak possible relative bias in a power estimate that assumes exact equatorial placement.

Keep the RMS calibration through the flux calculation

Peak E is \(\sqrt2(0.00200)=0.002828\) V/m. With \(k=2\pi f/c\simeq6.29\) m⁻¹, \(p_0=4\pi\epsilon_0r E_{\rm peak}/k^2\simeq3.98\times10^{-14}\) C m. Alternatively use RMS E directly to find

\[S=E_{\rm rms}^2/Z_0=1.06\times10^{-8}\,\mathrm{W/m^2}.\]

The inferred total is \((8\pi/3)(25)S=2.22\) μW. At a 5° displacement from the maximum the measured flux is multiplied by \(\cos^2 5^\circ=0.9924\), so the inferred total can be low by 0.76%. A comparable angular error near an axial null produces a much larger relative uncertainty.

Tutorial · use a symmetry-breaking parameter as a diagnostic

Two opposing parallel dipoles have moment magnitudes \(p(1+\delta)\) and \(p(1-\delta)\), with \(kd=0.20\). Derive the exact direction-dependent pair factor, estimate the equatorial-to-45° intensity ratio for \(\delta=0.010\), and explain why this experiment cannot determine the sign of a small real imbalance from total intensities alone in this geometry.

Retain the phase of each current element

With \(q=kd\cos\theta/2\), choose pair factor \((1+\delta)e^{-iq}-(1-\delta)e^{iq}=2\delta\cos q-2i\sin q\). The intensity pattern is proportional to \(4\sin^2\theta(\delta^2\cos^2q+\sin^2q)\). At the equator q=0, so the intensity factor is

\[4\delta^2=0.0004.\]

At 45° q=0.07071 and the factor is about 0.01018. The ratio is 0.0393. The residual electric-dipole and leading quadrupole terms here occur in quadrature, eliminating their cross term for a real imbalance. Reversing its sign leaves each intensity unchanged. A phase-sensitive reference at the equator could recover that sign.

David Tong, University of Cambridge · radiated fields of localized currents and multipole radiation

Scattering, extinction and the phase of the forward wave

A suspension of transparent particles dims a narrow transmitted beam while absorbing almost none of its energy. Derive the scattered angular power, identify the interference term seen in transmission, and use energy conservation to put a bound on the response of a single small particle.

Build the cross sections from a specified incident beam

Illuminate an isolated target in a uniform transparent host by a monochromatic plane wave of incident intensity \(I_0\). A far-away receiver collecting solid angle \(d\Omega\) measures scattered power \(dP_{\rm sca}\). Define \(d\sigma_{\rm sca}/d\Omega=(dP_{\rm sca}/d\Omega)/I_0\) and integrate over direction to obtain \(\sigma_{\rm sca}\). Dividing internally dissipated power by the same incident intensity defines \(\sigma_{\rm abs}\). Extinction is \(\sigma_{\rm ext}=\sigma_{\rm sca}+\sigma_{\rm abs}\) for a passive isolated object in a lossless surrounding medium. All three have dimensions of area, even for a particle that has no sharply defined physical footprint.

The geometrical area of an object and its cross section answer different questions. A transparent object much smaller than its wavelength may scatter only a small fraction of the power geometrically incident on its silhouette. A resonant dipole can draw energy from an effective area comparable to a wavelength squared, much larger than a nanoparticle's silhouette. The incident field and the disturbance it generates coexist in the forward direction. Removing a fixed area from a ray diagram cannot represent the interference between those fields.

Represent the incident polarization by a normalized complex vector \(\mathbf e_0\perp\widehat{\mathbf z}\). Define a vector scattering amplitude of dimensions length by \(\widetilde{\mathbf E}_{\rm sca}=E_0 e^{ikr}\mathbf f(\mathbf n)/r+O(r^{-2})\) for the same \(e^{-i\omega t}\) convention. The scattered wave is transverse to n; for a polarization-insensitive receiver \(d\sigma/d\Omega=|\mathbf f|^2\). With a receiving analyser \(\mathbf a\) only \(|\mathbf a^\dagger\mathbf f|^2\) is detected. Thus an intensity pattern alone loses information about phase and possibly polarization. The forward extinction will depend on one particular quadrature of that phase.

Derive the small sphere's polarizability from two boundary equations

In vacuum take a dielectric sphere of radius a with scalar relative permittivity \(\epsilon_r\) at the driving frequency. For \(ka\ll1\) and negligible retardation inside the sphere, solve the instantaneous-looking boundary problem for a phasor incident field \(E_0\hat z\). Axial symmetry and the degree-one angular dependence admit \(\Phi_{\rm in}=-C r\cos\theta\) and \(\Phi_{\rm out}=-E_0r\cos\theta+D\cos\theta/r^2\). At r=a continuity of tangential E is equivalently continuity of these potentials; continuity of normal D supplies the other equation. They give

\[C=E_0-D/a^3,\]
\[\epsilon_r C=E_0+2D/a^3,\]
\[D=a^3{\epsilon_r-1\over\epsilon_r+2}E_0.\]

Comparing the decaying term with a dipole potential gives

\[p=4\pi\epsilon_0D.\]

Define the volume polarizability by \(p=\epsilon_0\alpha E_0\), so \(\alpha_0=4\pi a^3(\epsilon_r-1)/(\epsilon_r+2)\) in m³. Some conventions absorb \(\epsilon_0\) in \(\alpha\). Naming the convention avoids spurious permittivity factors when scattering formulas are converted between sources. At \(\epsilon_r\to1\) the particle becomes indistinguishable from its environment and the dipole vanishes. In the formal electrostatic conducting limit the coefficient tends toward \(4\pi a^3\).

Radiation from this induced electric dipole gives

\[\mathbf f(\mathbf n)={k^2\alpha\over4\pi}\,[\mathbf e_0-\mathbf n(\mathbf n\cdot\mathbf e_0)],\]
\[\sigma_{\rm sca}={k^4\over6\pi}|\alpha|^2 .\]

The projection shows why scattered light from unpolarized illumination becomes partially polarized at an angle: average the power of two orthogonal transverse incident polarizations. For observation angle \(\theta\) to the incident wavevector, the normalized angular factor is \((1+\cos^2\theta)/2\). At 90° an analyser can suppress the surviving polarization. The total cross section is independent of the orientation of a single linear polarization because the isotropic sphere can be rotated with that polarization.

Predict an absolute scale as well as a wavelength slope

For a transparent sphere \(a=20\) nm, index 1.50 so \(\epsilon_r=2.25\), and \(\lambda_0=600\) nm, the contrast factor is 0.2941 and \(ka=0.2094\). The quasistatic volume polarizability is \(2.96\times10^{-23}\) m³. Substitution gives \(\sigma_{\rm sca}\simeq5.6\times10^{-19}\) m² compared with geometric area \(1.26\times10^{-15}\) m². At otherwise fixed properties, halving radius divides \(|p|\) by eight and \(\sigma_{\rm sca}\) by 64. Changing wavelength from 600 to 500 nm instead increases the leading cross section by \((600/500)^4=2.074\). This scaling assumes that material dispersion and finite-size corrections have stayed sufficiently small.

For a dilute suspension with \(N=10^{16}\) particles/m³ path loss from independent scattering gives

\[dI/dz=-N\sigma_{\rm ext}I.\]

Over 0.10 m at the 600 nm parameters, optical depth is about \(5.6\times10^{-4}\), or 0.056% collimated intensity loss. Collecting a wider transmitted cone can admit some of the scattered light and reduce that apparent extinction. At high density fields scattered by one particle drive others and positional correlations can alter angular scattering. The isolated-particle prediction and exponential independent-particle extrapolation should be tested separately.

Change particle radius and compare a calculated scattering cross section

Find an interference signal that survives at arbitrarily large distance

Write the total field outside the scatterer as incident plane wave plus outgoing spherical wave. The Poynting flux through a large sphere contains incident-only, scattered-only and cross terms. The net incident-only flux through a closed sphere vanishes. The scattered-only term tends to \(I_0\sigma_{\rm sca}\). The interference term accounts for the reduction of incident energy in the forward beam. To see its scaling, examine a narrow forward cap; in a scalar polarization-preserving calculation the relevant angular oscillation is \(e^{ikr(1-\cos\theta)}\). The interference field is order \(1/r\), but the integration area is order \(r^2\); oscillatory phases cancel over most directions and leave a forward contribution of finite order.

Near the cap \(\theta\ll1\), \(1-\cos\theta\simeq\theta^2/2\), \(d\Omega\simeq2\pi\theta d\theta\). Introduce a smooth angular acceptance equal to one near zero. The leading forward factor in the integral is

\[2\pi\int_0^\infty \theta e^{ikr\theta^2/2}d\theta=2\pi i/(kr),\]

with arbitrarily weak positive damping understood before taking the large-radius limit. Magnetic and electric interference terms have the same forward polarization and supply twice the real cross product in total flux. A backward stationary contribution is cancelled by the opposing propagation directions in the net flux. With the outgoing-wave convention this gives

\[\sigma_{\rm ext}={4\pi\over k}\Im[\mathbf e_0^*\cdot\mathbf f(\widehat{\mathbf z})].\]

This is the optical theorem. A forward detector sensitive only to \(|\mathbf f(0)|^2\) is insufficient; the unscattered incident field acts as a coherent reference that picks out the appropriate quadrature. Changing the scattering-amplitude convention changes corresponding signs. Inserting a known passive dipole is a quick way to verify the convention used in a computational implementation.

There is an equivalent small-particle derivation. The cycle-averaged work extracted from a prescribed incident electric field is

\[\langle\mathbf E_{\rm inc}\cdot\dot{\mathbf p}\rangle=(\omega/2)\operatorname{Im}(\widetilde{\mathbf E}_{\rm inc}^*\cdot\widetilde{\mathbf p}).\]

Dividing by \(I_0=|E_0|^2/(2Z_0)\) gives

\[\sigma_{\rm ext}=k\operatorname{Im}\alpha.\]

In the forward direction the dipole formula gives \(\mathbf e_0^*\cdot\mathbf f(0)=k^2\alpha/(4\pi)\), reproducing that result exactly. Comparing integrated scattered power with interference-derived extinction tests both amplitude normalization and global energy accounting.

Repair the apparent contradiction of a real static polarizability

A strictly real static \(\alpha_0\) gives positive dipole radiation in \(\sigma_{\rm sca}\), yet inserting that same real number into \(k\Im\alpha\) would give zero extinction. The two formulas then mix orders of approximation. Replacing the driving field by its electrostatic value determined the leading in-phase moment. The small imaginary part needed to supply radiated energy arises at the next electrodynamic order. For a lossless purely dipolar particle energy conservation requires \(\sigma_{\rm ext}=\sigma_{\rm sca}\), hence

\[\Im\alpha={k^3\over6\pi}|\alpha|^2,\]
\[\Im(1/\alpha)=-{k^3\over6\pi}.\]

Retaining the static inverse real part yields a simple radiation correction \(\alpha=[\alpha_0^{-1}-ik^3/(6\pi)]^{-1}\). For a real \(\alpha_0\) this expression obeys the lossless optical theorem. It captures the radiative imaginary correction while ignoring possible real dynamic depolarization and higher multipoles; it is not an exact all-size sphere solution. If the material itself absorbs, a passive \(\alpha_0\) contributes additional loss, and \(\sigma_{\rm abs}=k\Im\alpha-k^4|\alpha|^2/(6\pi)\) must remain nonnegative.

Define \(b=k^3\alpha/(6\pi)\). Passivity is \(\Im b\ge|b|^2\), which is the disk \((\Re b)^2+(\Im b-1/2)^2\le1/4\) in a complex-amplitude diagram. Points on the boundary are purely radiative dipoles; interior points have additional internal absorption. The largest possible \(|b|\) is one at \(b=i\), giving \(\sigma_{\rm sca}=6\pi/k^2=3\lambda^2/(2\pi)\). At that point the particle is lossless and extinction is all scattering. The largest absorption occurs instead at \(b=i/2\). There \(k\Im\alpha=3\pi/k^2\), scattering is \(1.5\pi/k^2\), and the difference \(1.5\pi/k^2\) is absorbed. The result applies to one ideal electric dipole channel with the stated normalization. Additional channels can contribute separately for a larger or more complex object.

Choose the detector geometry that answers the desired question

A narrow-aperture transmission experiment measures an extinction-like signal if it isolates the original mode. A large integrating sphere estimates total outgoing scattered flux over its acceptance and provides an independent \(\sigma_{\rm sca}\); a temperature-rise measurement estimates heat deposition. For the same incident beam, the combination should satisfy

\[P_{\rm ext}=P_{\rm sca}+P_{\rm abs}.\]

Measuring extinction and assuming it is all absorption can exaggerate heating by orders of magnitude for transparent dielectric particles. Conversely reflection plus a small-angle detector may miss side-scattered light and turn that deficit into an apparent unexplained source term.

Suppose a calibrated intensity is \(2.0\times10^4\) W/m², transmission implies 60 pW extracted per particle, and integrated scattering gives 45 pW. The inferred cross sections are \(3.0\times10^{-15}\) and \(2.25\times10^{-15}\) m², leaving \(0.75\times10^{-15}\) m² for absorption and 15 pW thermal load. If each of the two power readings has independent 5 pW standard uncertainty, the difference has about 7.1 pW uncertainty. The inferred absorption is then much less certain in relative terms than either directly measured quantity. A negative fitted difference within that uncertainty should prompt an examination of collection angles and background subtraction rather than an immediate interpretation as optical gain.

How energy conservation fixes a scattering phase

The forward optical theorem can appear surprising because it relates a single angular amplitude to a sphere-integrated power. For a spherical scatterer this relationship can be seen one angular momentum channel at a time. Begin with a scalar plane wave scattering elastically from a spherically symmetric object in a lossless exterior. This scalar example exposes the mathematics; electromagnetic spherical waves have separate electric and magnetic polarisation families and start at angular momentum one. A scalar zeroth channel should never be inserted directly into a vector light-scattering calculation.

Outside a sphere containing the object, the radial equation for each Legendre component has independent incoming and outgoing spherical solutions. Define \(S_\ell\) as the ratio of outgoing to incoming wave amplitudes relative to its value for free propagation. The radial energy flux in a channel is proportional to the squared magnitude of the outgoing amplitude minus that of the incoming amplitude. For an elastic scatterer flux balance demands \(|S_\ell|=1\). Set \(S_\ell=e^{2i\delta_\ell}\) with real phase shift \(\delta_\ell\). The scattered outgoing wave is the change from the unscattered outgoing part, proportional to \(S_\ell-1\).

\[f(\theta)=\frac1k\sum_{\ell=0}^\infty(2\ell+1)e^{i\delta_\ell}\sin\delta_\ell\,P_\ell(\cos\theta),\]
\[\sigma_{\rm sca}=\frac{4\pi}{k^2}\sum_\ell(2\ell+1)\sin^2\delta_\ell .\]

The second result follows by integrating \(|f|^2\) and using \(\int_{-1}^{1}P_\ell P_m\,du=2\delta_{\ell m}/(2\ell+1)\). At forward angle all Legendre functions equal one. The imaginary part of \(e^{i\delta}\sin\delta\) is \(\sin^2\delta\), exactly the quantity appearing in the integrated cross section. This equality in each uncoupled channel proves the elastic optical theorem in the scalar example. It does not require the forward intensity \(|f(0)|^2\) to have any particular value. The calibrated phase of the forward amplitude is essential.

For a hypothetical acoustic sphere at wavenumber \(k=20\) per metre, suppose only the scalar zeroth phase shift is appreciable and has \(\delta_0=\pi/6\). Its scattering amplitude has real part 0.0217 m and imaginary part 0.0125 m, independent of viewing angle. Integrating its differential cross section gives \(4\pi(0.025\,\mathrm m)^2=0.00785\) square metres. The forward identity gives \(4\pi(0.0125)/20=0.00785\) square metres as well. Shifting the phase through \(\pi/2\) at this wavenumber increases the cross section by four, to the single-channel elastic maximum.

What an incomplete outgoing channel tells the experimenter

For an absorbing or internally converting target write \(S_\ell=\eta_\ell e^{2i\delta_\ell}\), \(0\leq\eta_\ell\leq1\). The missing outgoing flux in that exterior channel contributes to absorption or to unobserved channels, depending on the physical system. Define \(a_\ell=(S_\ell-1)/(2i)\), so the scalar wave amplitude above uses \(a_\ell=e^{i\delta_\ell}\sin\delta_\ell\) in the purely elastic limit. Elementary algebra gives

\[\operatorname{Im}a_\ell-|a_\ell|^2=\frac{1-|S_\ell|^2}{4},\]
\[\sigma_{\rm abs}=\frac{\pi}{k^2}\sum_\ell(2\ell+1)(1-\eta_\ell^2).\]

For a single channel with \(\eta=0\), the scattered amplitude is \(i/2\). The residual coherent outgoing component relative to its incident plane-wave background corresponds to a finite scattered power even though this channel has zero total outgoing radial amplitude. Its absorbed and scattered cross sections are equal, while extinction is their sum. This distinction is the angular-channel counterpart of interference between incident and scattered fields in the forward direction.

An experiment may infer \(\eta<1\) because the detector fails to collect another outgoing polarisation, a converted elastic mode or a large-angle part of the pattern. To assign true heat absorption one needs the full exterior channel accounting or a calorimetric measurement. For a homogeneous liquid suspension distinguish energy dissipated in the nominal particles from energy dissipated in the surrounding medium. The preceding cross-section definitions assume a nonabsorbing reference host, so a lossy host requires an explicit incident-reference subtraction and an agreed control surface.

Suppose a measurement models the target only as an isotropic scalar scatterer, yet detects a pronounced forward lobe. A one-channel fit can reproduce a forward complex amplitude by choosing an appropriate complex \(a_0\), but it also predicts the same intensity at every other angle. Add a possible \(\ell=1\) component and measure at \(\theta=0,\pi/2,\pi\). At right angles the term proportional to \(P_1\) vanishes, which helps isolate the \(\ell=0\) component. Sum and difference of complex forward and backward amplitudes separate even and odd parity. Intensity-only data lose signs and relative phase and may require additional incident conditions or interferometry.

To check a numerical partial-wave calculation, increase the highest retained order at fixed geometry and compare the integrated angular quadrature with the coefficient sum. These diagnostics test the angular grid and truncation separately. A narrow forward peak may contribute little at any grid point if no nodes resolve its centre, yet contribute substantially to extinction. Gauss–Legendre quadrature in \(u=\cos\theta\) automatically includes the solid-angle measure. Finally compare the coefficient-sum extinction against the imaginary forward value with the chosen time convention. A sign error in outgoing radial waves can produce a beautifully converged negative extinction for a passive sample.

Track the frequency dependence of a scattering signal

Change the ratio of forcing to resonance frequency. Decide which part of the response determines a scattering measurement and compare it with the power balance in the text.

Worked suspension problem · infer and check an optical depth

A dilute suspension has independently measured single-particle extinction cross section \(5.0\times10^{-15}\) square metres and particle density \(3.0\times10^{14}\) per cubic metre. A narrow stop rejects the scattered halo. Predict the direct transmission through 20 mm and estimate how many particles occupy a cylindrical illuminated volume of radius 0.10 mm. Which approximation is most vulnerable if the radius is increased?

Derive the transport law and identify the role of the aperture

In an infinitesimal length \(dz\), the direct-beam intensity loses a fraction \(n\sigma_{\rm ext}dz\) in the independent, uniform, dilute limit. Integrating gives

\[I/I_0=e^{-n\sigma_{\rm ext}L}.\]

The extinction coefficient is 1.50 per metre and optical depth 0.0300, implying direct transmission 0.9704. A first-order calculation gives 0.9700. The small difference is consistent with neglect of higher powers in optical depth, but the exponential by itself does not describe multiple scattering into the receiver.

The illuminated volume is \(\pi(10^{-4})^2(0.020)=6.28\times10^{-10}\) cubic metres and contains about 188,000 particles on average. Increasing beam radius at fixed density and path length raises this count but leaves ideal optical depth unchanged. Counting more independent scatterers reduces relative sample fluctuations. It can, however, change beam divergence, spatial illumination and what scattered angles reach a finite detector. There is no general reason for local diluteness to fail merely because the beam area is larger.

Interchange cells of several lengths and measure the slope of the logarithm of transmitted intensity. An intercept different from zero suggests interface loss or a calibration offset if both incident and transmitted powers are referenced outside the cell. Repeat the length scan with a wider angular stop. A reduced slope with the wide stop signals that the detector collects part of the scattering halo; a genuine absorption contribution persists. At higher densities, evaluate interactions between particles or coherent structure before extrapolating the dilute-solution cross section from the same attenuation law.

A scattering measurement weights the large end of a distribution

The small-particle scattering law grows as the sixth power of radius for fixed material contrast and wavelength. A suspension with a modest spread of radii can therefore scatter substantially more than a calculation using the mean radius for every particle. If radii are independently distributed with mean \(a_0\) and small fractional standard deviation \(s\), expand \(a^6=a_0^6(1+\delta)^6\). The first correction to the ensemble mean is \(15s^2\) times the monodisperse value when the centred deviations average to zero. At ten percent relative spread, the leading increase is fifteen percent.

Separately measuring total particle material changes the comparison. Material volume scales as the third power, whose corresponding correction is \(3s^2\). At fixed material volume, the scattering per unit volume therefore increases by approximately \(12s^2\) relative to spheres of mean radius, within the same narrow-distribution approximation. Reporting the quantity held fixed changes the numerical prediction meaningfully.

A few larger outliers can invalidate this expansion and even take the sample beyond the Rayleigh regime. Measure a size distribution independently and average the single-particle cross section over that distribution, including detector acceptance if it varies with size. A fit to a single apparent radius may match total intensity at one wavelength while failing its spectral slope or angular pattern. Comparing two wavelengths and a separate volume estimate gives a practical check on that hidden weighting.

Tutorial · examine two proposed dipole fits for passivity

At a fixed wavelength two fits to an angular intensity pattern return \(b_1=0.30+0.10i\) and \(b_2=0.30-0.10i\), with \(b=k^3\alpha/(6\pi)\). Can angular intensity distinguish them? Find normalized scattering, extinction and absorption by dividing each cross section by \(6\pi/k^2\). Which fit can describe a passive particle?

Compare interference with scattered intensity

Both have \(|b|^2=0.10\), giving the same angular scattering and normalized scattered cross section 0.10. Extinction in these units is \(\Im b\), hence +0.10 or −0.10. Absorption is the difference, zero or −0.20. The first sits on the lossless passivity circle. The second requires an active energy supply if described by these conventions. Even an angular pattern measured over the whole sphere would retain that ambiguity because it contains squared magnitudes. The forward interference phase or an independent extinction reading discriminates.

Tutorial · recover a particle radius with a stated systematic uncertainty

At fixed wavelength and index a dilute sample scatters 1.50 times the reference signal per unit volume. Assume initially the same number density and a Rayleigh regime. Infer the radius ratio. Then allow number density to be 20% higher than assumed. Estimate how much of the signal difference could instead be a concentration effect, and propose a phase-sensitive check of the dipole interpretation.

Track the powers of radius and concentration separately

Scattered power is proportional to \(Na^6\) under these assumptions, so the radius ratio is

\[1.50^{1/6}=1.070.\]

If number density is actually 1.20 times the reference, the ratio becomes

\[(1.50/1.20)^{1/6}=1.038.\]

An apparently precise intensity can therefore constrain a combined quantity quite well without determining either factor separately. Measure an independent particle count or concentration. A forward extinction measurement should satisfy the optical theorem, while the real part of the dilute coherent refractive response scales mainly with \(N\Re\alpha\sim Na^3\). Combining these observables is better conditioned than repeating a single intensity measurement.

Barton Zwiebach, MIT · optical theorem and the forward scattering amplitude

David Tong, University of Cambridge · scattering, induced dipoles and electromagnetic radiation

Diffraction from the near field to the focal plane

An illuminated aperture is a boundary condition for a wave. A screen a millimetre away, an intensity camera at a lens focus and a microscope measuring an evanescent field sample different consequences of the same condition. We will derive operators for propagating the field, estimate the approximations each instrument makes and use energy and sampling checks to tell numerical structure from a measurable fringe.

How each spatial frequency propagates

Take a monochromatic scalar field with physical value given by the real part of \(U(x,y,z)e^{-i\omega t}\). This approximates one transverse component when the polarisation remains nearly uniform and angles are small. In a homogeneous transparent half-space it obeys the Helmholtz equation. Specify the complex amplitude in the plane \(z=0\) and require outgoing or decaying waves for positive \(z\). Fourier transform the two transverse coordinates, leaving a differential equation in the third.

\[\partial_z^2\widehat U+(k^2-k_x^2-k_y^2)\widehat U=0,\]
\[\widehat U(k_x,k_y,z)=\widehat U(k_x,k_y,0)e^{ik_z z},\]
\[k_z=\sqrt{k^2-k_x^2-k_y^2}.\]

Choose the root with positive real part for propagation and positive imaginary part for decay. Each propagating component advances in phase. Hence power integrated over a plane is unchanged for a paraxial beam with no absorbing aperture downstream. For angles approaching grazing incidence the weight for normal flux contains the direction cosine. Components with transverse wavenumber exceeding \(k\) decay exponentially. An aperture map thus contains structures invisible to a distant measurement even if the map itself is known exactly.

In vacuum a sinusoidal field structure of period 400 nm illuminated at 600 nm has \(k_x/k=1.50\). Its amplitude has fallen to \(1/e\) after \(1/(k\sqrt{1.5^2-1})=85.4\) nm. At 500 nm the remaining amplitude is 0.00287 and the squared amplitude is roughly eight parts in a million of its plane value. A numerical back-propagation that reinstates the original component also multiplies measurement errors by about 350. Improving detector gain does not restore the unknown phase.

A propagation kernel with a controlled phase error

For small transverse wavenumber, expand \(k_z=k-k_\perp^2/(2k)-k_\perp^4/(8k^3)+\cdots\). The first correction becomes a chirp in Fourier space. Completing the square in its inverse transform gives the Fresnel kernel. Write \(\mathbf r\) for a transverse observation point and \(\boldsymbol\xi\) for a point in the aperture.

\[U(\mathbf r,z)\simeq\frac{e^{ikz}}{i\lambda z}\int U(\boldsymbol\xi,0)\exp\!\left[\frac{ik}{2z}|\mathbf r-\boldsymbol\xi|^2\right]d^2\xi .\]

This expression retains phase curvature across the aperture. The coefficient ensures that a spatially uniform boundary amplitude reproduces a uniform plane wave. An uncovered infinite plane is a useful test for a numerical convolution, although a finite computation needs padding or a truly periodic uniform test. A measured slit has sharp edges with broad spatial spectra, so peak error near an edge can exceed the error suggested by a small angle evaluated for the central lobe.

At an observation angle \(\theta\) a propagation distance \(z\) accumulates neglected phase of order \(kz\sin^4\theta/8\). For \(z=0.10\) m, \(\lambda=500\) nm and \(\theta=0.01\) rad this is 0.00157 rad. At 0.05 rad it is close to one radian. A faint sidelobe at a moderately large angle can require exact angular-spectrum propagation even while a paraxial estimate describes the central spot beautifully.

Which quadratic term can the far field lose?

Expand the kernel's square into an observation phase, a source phase and a bilinear term. Only the source phase can be dropped without changing the predicted intensity directly through that factor. For source radius \(a\) its maximum value is \(\pi a^2/(\lambda z)\). The remaining integral is the Fourier transform of the aperture at spatial frequencies \(x/(\lambda z),y/(\lambda z)\). Define the Fresnel number using the half-width \(a\). A convention based on full slit width gives a value four times larger.

\[U(\mathbf r,z)\simeq\frac{e^{ikz+ikr^2/(2z)}}{i\lambda z}\,\widehat U\!\left(\frac{kx}{z},\frac{ky}{z},0\right),\]
\[N_F=\frac{a^2}{\lambda z}.\]

For a uniformly illuminated slit of full width \(w=0.20\) mm at 532 nm and \(z=1.0\) m, \(N_F=0.0188\). Direct integration of the linear aperture phase gives

\[I/I_0=\mathrm{sinc}^2(\pi wx/\lambda z),\]

where \(\mathrm{sinc}(u)=\sin(u)/u\). The first zeros should be 2.66 mm either side of centre. The edge phase is 0.059 rad. Moving the screen to 30 mm gives \(N_F=0.627\) and edge phase 1.97 rad. Substituting the smaller distance in the far-field formula yields a number but no longer a controlled approximation.

Compare near- and far-field predictions in the slit integral

In that experiment reduce the mesh interval before moving the screen. If the exposed variable counts panels, doubling panels at fixed aperture halves the interval. A converged difference between the full and far-field integrals is a physical failure of the approximation. A feature that moves each time the number of source samples doubles is a numerical failure. Keep the same physical horizontal axis and the same normalisation when comparing adjacent screens.

From a circular pupil to a resolution measurement

When the pupil is a disk, polar coordinates considerably simplify the Fourier integral. Align the transverse transform vector along the horizontal axis. The angular average of \(e^{-iqr\cos\phi}\) defines \(J_0(qr)\). One radial integration, using \(d[uJ_1(u)]/du=uJ_0(u)\), then gives the result. Divide by the on-axis amplitude, proportional to aperture area.

\[\frac{U(q)}{U(0)}=\frac{2}{a^2}\int_0^a rJ_0(qr)\,dr=\frac{2J_1(qa)}{qa},\]
\[q=k\sin\theta .\]

At \(qa=0\) use \(J_1(s)\sim s/2\). The first zero is at \(qa=3.8317\). Hence a disk of diameter \(D\) has its first dark ring at \(\sin\theta=1.22\lambda/D\). Two mutually incoherent identical points contribute the sum of their intensities. Rayleigh's conventional separation places each peak on the first zero of its neighbour. A coherent pair instead has an interference term that depends on the unknown relative phase. The same separation criterion cannot predict its measured trough without that phase.

A 5.0 mm pupil on a 100 mm focal-length lens at 550 nm gives a first-zero radius of 13.4 micrometres on the focal plane. A camera with 6.5 micrometre pixels spans the full bright core with about four pixels. Fitting the central pixel alone to find the image position would depend strongly on whether the spot lay on a pixel centre or a corner. A joint fit to integrated pixel intensities can estimate a position more precisely than the image width when enough photons are detected. That precision describes one isolated spot and does not directly give a two-source resolution.

Why a lens puts the spectrum close at hand

A thin positive lens adds the quadratic phase \(-kr^2/(2f)\) to a field immediately in front of it. At the plane \(z=f\), this cancels the source term of the Fresnel kernel exactly within paraxial theory. The focal intensity therefore samples a Fourier spectrum even for a tabletop lens standing much nearer than the free-space far-field distance. The physical exit pupil remains part of the amplitude. Closing it removes high transverse spatial frequencies in an imaging arrangement and broadens the spot of a point emitter.

For illumination with Gaussian amplitude \(U\propto e^{-r^2/w^2}\), completing the transverse Fourier integrals gives another Gaussian, with focal-plane amplitude radius \(w_0=\lambda f/(\pi w)\) for a broad lens and an incident flat wavefront. If \(w=1.0\) mm, \(f=100\) mm and \(\lambda=633\) nm, \(w_0=20.1\) micrometres. This is the \(1/e\) field radius, also the \(1/e^2\) intensity radius. The Rayleigh length \(\pi w_0^2/\lambda\) is 2.02 mm. Moving a detector one Rayleigh length off the waist increases the radius by \(\sqrt2\) and halves its on-axis intensity for fixed total beam power.

Use the ray-bundle experiment to locate the geometric focus before estimating its diffractive width

From a point image to transmitted object contrast

A microscope may resolve individual test objects yet deliver very little contrast for a periodic specimen at a similar length scale. The reason is that incoherent imaging acts linearly on intensity, while coherent imaging acts linearly on field amplitude. Start with mutually incoherent object points. Their expected image intensities add, so the image is the convolution of object intensity with a nonnegative intensity point-spread function \(h=|h_A|^2\), where \(h_A\) is the coherent amplitude impulse response. The Fourier transform of \(h\), normalised to one at zero spatial frequency, is the optical transfer function. Its magnitude describes attenuation of a sinusoidal intensity modulation.

For a focused unaberrated system the coherent amplitude response in Fourier space is the pupil function. The convolution theorem applied to \(|h_A|^2\) shows that the incoherent transfer function is the pupil autocorrelation. For a clear circular pupil this amounts to asking how much two equal disks overlap as their centres separate. The overlap consists of two circular sectors minus their triangular parts. With normalised frequency \(s=f/f_c\) and incoherent cutoff \(f_c=2\,\mathrm{NA}/\lambda_0\) in object space, the result is

\[M(s)=\frac2\pi[\arccos s-s\sqrt{1-s^2}],\quad 0\le s\le1,\]
\[M(s)=0\quad(s>1).\]

Here \(\lambda_0\) is vacuum wavelength and \(\mathrm{NA}=n\sin\theta_{\max}\). At \(s=0\) the disks coincide and the full mean intensity passes. At the cutoff their edges just touch and sinusoidal contrast vanishes. The coherent pupil transmits field spatial frequencies only through \(\mathrm{NA}/\lambda_0\). These two cutoffs answer different questions about different object and illumination statistics. A coherent phase grating viewed in exact focus can yield an almost uniform intensity image despite transmitting several field components.

For \(\mathrm{NA}=0.25\) at 550 nm, the incoherent cutoff is 909 cycles/mm. A sinusoidal target of 450 cycles/mm has \(s=0.495\) and \(M\simeq0.396\). An object with 0.60 sinusoidal intensity visibility is predicted to show about 0.238 before detector averaging. If the object-referred pixel width is 0.75 micrometres, rectangular pixel integration multiplies this contrast by \(\mathrm{sinc}(\pi fp)=0.823\); the recorded visibility is about 0.196. Nyquist frequency for this pixel spacing is 667 cycles/mm. Hence even some frequencies that the optics can transmit lie above the detector Nyquist limit and can alias back to lower apparent frequencies.

This prediction can be tested with an adjustable magnification while keeping entrance pupil and object fixed. Object-referred pixel width falls as magnification rises; a pixel-limited measurement should approach the optical transfer curve. Raising magnification also spreads light over more pixels, changing per-pixel count noise, so compare fitted contrasts with uncertainty. At frequencies where the ideal transfer is small, a high-contrast target and low read noise matter. Dividing by an arbitrarily small transfer function to sharpen the final image can turn noise into a convincing periodic pattern.

A pupil-phase error redistributes energy without absorbing it

Introduce a known defocus into a clear circular pupil. Let the phase relative to its centre vary as \(\phi(r)=\Phi r^2/a^2\). The on-axis focal amplitude is proportional to the pupil average of \(e^{i\phi}\), since all ideal contributions arrive in phase there. Integrate in polar coordinates and substitute \(u=r^2/a^2\). Relative to the perfect on-axis intensity the result is

\[S=\left|\int_0^1e^{i\Phi u}du\right|^2=\left[\frac{\sin(\Phi/2)}{\Phi/2}\right]^2 .\]

This special-case Strehl ratio assumes a uniform pupil and pure quadratic defocus. Removing a phase piston makes no change to intensity. Expanding for small \(\Phi\) yields

\[S=1-\Phi^2/12+\cdots.\]

The pupil-phase variance after removing the mean piston is \(\Phi^2/12\), which explains the leading connection between reduced peak intensity and wavefront variance without assuming that every type of aberration has the same pattern.

A quarter of a wave of centre-to-edge optical path error gives \(\Phi=\pi/2\) and \(S=0.811\). One half wave gives 0.405. In an ideal phase-only pupil the missing on-axis intensity appears elsewhere in the image; total transmitted power over a sufficiently wide observation plane is unchanged. Contrast this with an absorbing pupil that removes a uniform fraction of intensity everywhere. Measuring only the brightest pixel confuses the two. Measure integrated power over increasing radii and fit a spatial profile as well as a peak.

To turn this into an axial calibration, derive the edge phase from the distance mismatch. For a paraxial marginal ray in air making angle approximately \(\mathrm{NA}\), an axial shift \(\Delta z\) introduces a relative phase magnitude near \(k\,|\Delta z|\,\mathrm{NA}^2/2\). At \(\mathrm{NA}=0.10\), \(\lambda=500\) nm and \(|\Delta z|=25\) micrometres this is 1.57 rad, the quarter-wave case. With a larger numerical aperture use actual longitudinal wavevectors instead of the quadratic approximation and model polarisation where required. The formulas predict the same on-axis drop for positive and negative defocus. A single peak reading cannot give the sign of an axial misplacement; scanning through focus supplies that missing sign and can reveal an asymmetric aberration.

Distinguish aperture physics from quadrature error

Refine the aperture samples and vary their physical extent independently. A moving numerical null and a true diffraction minimum have different refinement signatures.

Worked optical problem · determine how much light fits into one Airy disk

Two groups compare image quality using respectively the peak intensity and the energy contained inside the first dark ring. Derive the encircled-energy fraction for a uniform circular pupil and obtain its value at the first ring. Would closing the aperture increase the useful energy fraction on a detector of fixed physical radius?

Integrate the radial intensity with its area measure

Write \(v=ka\sin\theta\), and use the small-angle focal-plane variable proportional to image radius. Focal intensity varies as \([2J_1(v)/v]^2\). The annular area element supplies a factor \(v\,dv\). Use \(J'_0=-J_1\) and \(J'_1=J_0-J_1/v\) to differentiate \(J_0^2+J_1^2\). The derivative is \(-2J_1^2/v\), giving the fraction inside radius \(v\) as \(1-J_0(v)^2-J_1(v)^2\). It tends to zero at the origin and to one at very large radius, which fixes the integration constants and normalisation without needing an absolute incident amplitude.

At \(v=3.8317\), \(J_1=0\) and \(J_0\simeq-0.4028\). The encircled fraction is therefore 0.838. The remaining 16.2 percent is outside the central disk even in a perfect ideal image. If the physical detector radius corresponded to this value before closing the pupil, reducing the pupil radius decreases \(v\) at the detector edge and therefore decreases the collected fraction. It also ordinarily reduces the total incident power transmitted by the pupil.

Peak-normalised plots rescale each pupil's image to one at its centre, which hides both effects. For a fair power comparison record the total incident flux, the pupil transmission and the energy on the fixed detector. A phase aberration or obscuration can leave the nominal first-zero position a poor boundary for comparing different pupils. The same physical encircled radius offers a reproducible metric in those cases, provided the beam centre and background are estimated independently.

A phase ramp moves a diffraction pattern without changing its shape

Illuminate a thin aperture with a tilted plane wave in the paraxial regime. At the aperture plane this multiplies its complex amplitude by a linear phase ramp. The Fourier shift theorem then moves the entire focal-plane amplitude by a transverse amount \(f\sin\theta_i\) along the tilt direction. Its intensity pattern retains its shape as long as the illumination envelope fills the pupil uniformly and the lens has enough acceptance. Tilting a narrow 532 nm beam by one milliradian in front of a 100 mm lens moves the pattern by about one tenth of a millimetre.

This provides a practical separation of phase tilt from aperture narrowing. A tilt moves both first zeros in the same direction, whereas changing the width of a centred slit moves the zeros apart or together. A position fit using one zero alone cannot separate these perturbations. Jointly fitting both zeros yields a mean position sensitive to tilt and a separation sensitive to width. A scanned detector with unequal position calibration on the two sides can mix the two observables.

For a spatially incoherent angular source, integrate intensities of the shifted patterns over the angular source distribution. An extended source then blurs zeros that would be sharp under one coherent angle. A coherent superposition of the same angular components instead requires adding the shifted amplitudes and can produce additional fringes. The illumination statistics determine which calculation describes the recorded image.

Tutorial · Distinguish a pupil defect from pixel integration

In a slit focal pattern the central lobe has one-sided first-zero distance 40 micrometres. An analyst samples precisely at that first zero using a centred pixel 8 micrometres wide and finds positive intensity. Estimate the finite-pixel fraction and propose a measurement that would expose an additional scattered background.

Show the pixel calculation and a discriminating test

Let \(x=x_0+s\), where \(|s|\) is much smaller than \(x_0\). The sinc amplitude near its zero is approximately \(-s/x_0\), giving intensity \(I/I_\mathrm{peak}\simeq s^2/x_0^2\). Averaging across a pixel of width \(p\) gives \(p^2/(12x_0^2)\), about \(3.33\times10^{-3}\). This estimate uses a flat response within each pixel and a sample centred on the true minimum. A two-micrometre centring error contributes about another 0.0025 at leading order.

Use magnification that doubles the first-zero distance in pixel units while keeping pupil and wavelength fixed. Pixel leakage at a centred zero should then fall by four relative to the peak. A background proportional to local scattered light may respond differently and a dark offset can be estimated from opaque-frame counts. Calibrate differing exposure and throughput, subtract dark counts prior to normalisation and fit both flanks to locate the true minimum.

Tutorial · Design a propagation-grid check

A 512-point transverse grid with 2 micrometre spacing represents an aperture at 600 nm. What angle can the grid represent? Could its periodically repeated boundary contaminate a nominal 0.08 rad bundle after 10 mm propagation, if the beam spreads from the centre? Explain two refinements that test distinct errors.

Show the angular and spatial budgets

Nyquist gives \(|k_x|\leq\pi/\Delta x\), hence

\[|\sin\theta|\leq\lambda/(2\Delta x)=0.15.\]

The 0.08 rad direction is resolved in principle, although modes near Nyquist would need a separate resolution study. Its lateral displacement over 10 mm is about 0.802 mm, larger than the 0.512 mm half-window even for a beam initially confined to its centre. A periodic FFT can therefore wrap light around into the opposite side.

Double the number of points with spacing fixed. This doubles the window while keeping the represented angular limit fixed. Then halve the spacing while doubling the number again to leave this enlarged window fixed and test transverse discretisation independently. Compare conserved flux, central intensity and the location of the first minimum, retaining absolute normalisation. Flux conservation in a periodic window can hold perfectly even when light has wrapped across its boundary. A plot of that single diagnostic would miss the contamination.

MIT 2.71 Optics · Fourier optics, apertures and propagation

Measure the phase speed of a numerical electromagnetic wave

Start with a lossless Maxwell wave, build a second-order time update and compare its actual travel time with what the continuum wave equation predicts.

A pulse can arrive late without losing energy

In a uniform lossless one-dimensional material take electric field along \(y\), magnetic field along \(z\) and propagation along \(x\). Maxwell's curl laws reduce to

\[\epsilon E_t=-H_x,\]
\[\mu H_t=-E_x.\]

Differentiate the first in time and substitute the second to obtain

\[E_{tt}=c^2 E_{xx},\]
\[c=1/\sqrt{\mu\epsilon}.\]

A real laboratory signal is a combination of spatial frequencies. Different errors in travel time for different components can distort its shape even when the scheme does not attenuate any resolved Fourier mode.

Use periodic boundaries so that reflection from an end cannot be confused with this effect. Scale distance by one wavelength and time by one exact period. The periodic field \(E(x,t)=\sin[2\pi(x-t)]\) has unit amplitude and returns to its initial shape after every integer period. A probe comparing just its envelope would miss a discrepancy in phase.

Derive the discrete dispersion relation

Take points separated by \(h\) and times separated by \(\Delta t\). Centred second differences give

\[u_j^{n+1}=2u_j^n-u_j^{n-1}+C^2(u_{j+1}^n-2u_j^n+u_{j-1}^n),\]

with \(C=c\Delta t/h\). Insert the complex trial field \(e^{i(j\theta-n\Omega)}\). The time pair contributes \(2\cos\Omega-2\), the spatial pair \(2\cos\theta-2\). The physical positive-frequency branch obeys

\[\sin(\Omega/2)=C\sin(\theta/2),\]
\[\frac{c_\mathrm{phase,grid}}{c}=\frac{\Omega}{C\theta}.\]

If \(0<C\le1\) a real \(\Omega\) exists for every grid phase, and each Fourier mode has constant discrete amplitude in exact arithmetic when started on one travelling branch. For \(C>1\) sufficiently rapid spatial oscillations have no real frequency. One time factor then grows. Testing stability on a single very smooth wave can miss this unstable part of the supported spectrum.

For long waves expand \(\sin\) and \(\arcsin\):

\[\Omega=C\theta+C(C^2-1)\theta^3/24+O(\theta^5).\]

The relative phase-speed error is \((C^2-1)\theta^2/24\) at leading order. Here increasing \(C\) towards one improves wave propagation. This special cancellation depends on a uniform one-dimensional grid, constant wave speed and the selected difference operators.

Initialise a clean numerical experiment

A second-order recurrence needs two time levels. Taking \(u_j^0=\sin(j\theta)\) and \(u_j^{-1}=\sin(j\theta+\Omega)\) excites a single right-going numerical mode. Using the exact continuum phase \(C\theta\) at the second level instead introduces a small mixture of right- and left-travelling grid modes. That is a valid test of initialisation, but it mixes errors if the quantity of interest is solely the numerical dispersion relation. State in your notes how the second level was produced.

The browser actually advances the nodal difference equations. It then reports the dispersion prediction as an independent check. The time is chosen as an integer number of numerical steps close to five exact periods and is stated with the result. At twelve points per wavelength and \(C=0.8\) there are fifteen steps per period. Both exact and discrete solutions have the same amplitude to roundoff. At the end of five periods examine how far their zero crossings have separated.

From a phase test to a pulse test

For a narrow packet, envelope motion is set by group velocity \(d\omega/dk\). Differentiate the discrete relation at fixed \(h,\Delta t\). The result is \(v_g/c=\cos(\theta/2)/\sqrt{1-C^2\sin^2(\theta/2)}\) on the positive branch for resolved nonendpoint modes. At \(C=0.8\) a mode close to the grid Nyquist limit has small group speed. A wave carrier and its envelope can show different speed errors. In a real dielectric wavelength dependence may also come from the material itself; a grid-refinement test with unchanged material law separates these contributions.

As an independent benchmark, set \(C=1\). Then \(\Omega=\theta\) for \(0\le\theta\le\pi\), and the right-going recurrence translates the samples exactly by one grid cell at each time step. The lab should align both curves even on a surprisingly coarse grid for this particular smooth periodic mode. This checks the sign and indexing of propagation without implying exact accuracy for arbitrary geometry and material interfaces.

Tutorial

A signal must accumulate less than 1 degree of phase error over ten periods. Estimate a required points-per-wavelength count for \(C=0.5\) using the leading error.

Work through the solution

The total continuum phase advance is \(20\pi\) rad. Requiring \(20\pi(1-C^2)(2\pi/N)^2/24<\pi/180\) gives \(N^2>450\pi^2\), or \(N\gtrsim67\). Evaluate the exact dispersion relation to check the chosen integer.

Why is measuring only the field at its crest a poor detector of small phase lag?

Work through the solution

The derivative of a sinusoid vanishes at its crest. A small phase shift changes that value only quadratically; at a zero crossing the change is linear. A phase fit using the entire ring is more robust than either single sample.

The numerical envelope changes after a wall is introduced. What additional tests would separate dispersion from reflection errors?

Work through the solution

First validate travel time on a uniform periodic domain. Next use a single known interface with an analytical reflection coefficient. Move the observation plane and refine the mesh separately. Compare reflected phase and amplitude with an energy-flux balance so a boundary error cannot masquerade as bulk dispersion.

Separate diffraction from a finite observation window

Recover the far-field angular spectrum of a smooth aperture, then isolate the errors from truncating and sampling the aperture field.

Begin with a transform that can be checked analytically

Consider a long slit system whose transmitted scalar field varies along one transverse coordinate \(x\). At a distant observation point in direction \(\theta\), a small aperture element accumulates an approximate relative phase \(-k x\sin\theta\). The Fraunhofer amplitude is proportional to \(\int A(x)e^{-2\pi i f x}\,dx\) with spatial frequency \(f=\sin\theta/\lambda\). The approximation neglects the quadratic phase across the aperture; either a suitable lens or sufficient propagation distance is needed. A numerical Fourier transform cannot cure violation of this optical assumption.

Take the ideal aperture field \(A(x)=e^{-x^2/w^2}\) and normalise far-field amplitude by its on-axis value. Integrating by parts or completing the square gives

\[F(f)/F(0)=e^{-(\pi wf)^2}.\]

One derivation avoids any complex contour: differentiate \(F\) with respect to \(f\) and replace \(xA=-(w^2/2)A'\). Integrating by parts gives

\[F'=-2\pi^2 w^2 f F.\]

Solve this first-order equation with the measured \(F(0)\). Thus a wider beam on the aperture narrows the far-field distribution. Squaring the amplitude gives the intensity measured by an ordinary detector.

At \(w=1\) mm, the \(1/e\) amplitude spatial frequency is \(1/(\pi w)\simeq0.3183\) cycles/mm. For 500 nm light this is a small angle of \(1.59\times10^{-4}\) radians. An instrument calibrated in radians per millimetre rather than cycles per millimetre would need a factor \(2\pi\); stating the Fourier convention prevents that frequent scale discrepancy.

What the instrument has really sampled

A scanner covers \(-W\le x\le W\) and gives one amplitude at each of \(N\) equally spaced cell midpoints. The numerical transform is the weighted sum \(\Delta x\sum_j A(x_j)e^{-2\pi ifx_j}\), where \(\Delta x=2W/N\). By symmetry its imaginary part vanishes for a perfectly centred real Gaussian; the program sums the cosine projection. It normalises by the numerical on-axis amplitude, allowing us to compare shapes on a common vertical scale.

Two separate approximations have entered. Truncating the aperture multiplies the field by a rectangle. In frequency space this convolves the Gaussian spectrum with a sinc and can produce signed sidelobes. Sampling at regular intervals makes the spectrum repeat up to a phase convention, with alias copies separated by \(1/\Delta x\). Increasing \(W\) at fixed \(N\) reduces truncation but worsens sampling. Widening the field of view and adding more detector pixels are not interchangeable changes.

Design a convergence test with two axes

Keep \(w=1\) mm and select 40 samples. Compare \(W=w\) and \(W=3w\). The aperture field at the boundary falls from \(e^{-1}\) to \(e^{-9}\), so an apparent sidelobe associated with the abrupt window should decrease strongly. Next fix \(W=3w\) and lower the number of samples. The displayed Nyquist frequency falls as \(\Delta x\) grows. When a plotted point lies above it, a smooth-looking value is an aliased sample of the periodic discrete spectrum.

At \(W=2w\), a centred Gaussian retains the on-axis amplitude fraction \(\operatorname{erf}(2)\simeq0.9953\) if integrated exactly. The normalised plot hides this 0.47% loss at zero frequency. If absolute power calibration matters, repeat the experiment without normalisation and independently integrate \(|A|^2\) across the aperture. A shape comparison and a throughput comparison are different measurements, both meaningful.

Recover a size from a far-field measurement

Suppose a detector measures the intensity falling to one half at \(f_{1/2}\). Since \(I/I_0=e^{-2(\pi wf)^2}\), the inferred \(w\) is \(\sqrt{\ln2/2}/(\pi f_{1/2})\). For \(f_{1/2}=0.1874\) cycles/mm the radius is about 1 mm. If the instrument actually reported amplitude half-width the corresponding formula would have \(\sqrt{\ln2}\) in the numerator; the radius would differ by a factor \(\sqrt2\). The raw measured quantity and its threshold should accompany any quoted fitted radius.

A positive intensity cannot distinguish a negative sidelobe amplitude from a positive amplitude of the same magnitude. To observe the sign change shown by the finite-window amplitude curve, interfere the field with a phase reference. Conversely, when comparing with a camera image, square the signed numerical amplitude once and apply the detector pixel average. Comparing a real-amplitude plot directly with a recorded intensity array is an avoidable model mismatch.

Tutorial

How could one distinguish an intrinsic physical sidelobe from ringing produced by the scanner window without a known reference aperture?

Work through the solution

Increase the scanned width while keeping \(\Delta x\) fixed by adding samples. Window artefacts should change as the omitted tails shrink. Repeat with a different smooth weighting and report its effect on resolution. An intrinsic feature that survives these tests can then be compared against an independent physical model.

At \(W=3\) mm and \(N=24\), what spatial frequencies can be represented without aliasing, and what does adding zero padding do?

Work through the solution

\(\Delta x=0.25\) mm, so the Nyquist limit is 2 cycles/mm. Zero padding supplies more displayed frequency samples of the same discrete transform. It adds no measured aperture detail and cannot resolve aliasing already present in the original samples.

A beam shifted by \(x_0\) within a sufficiently wide window has the same far-field intensity. What information changes?

Work through the solution

Substituting \(x'=x-x_0\) in the Fourier integral multiplies its amplitude by \(e^{-2\pi i f x_0}\). The phase ramp records the displacement; the intensity is invariant. A truncated window may break this invariance by clipping different amounts of field.

Estimate a cavity linewidth from a finite, biased record

Connect the time and frequency descriptions of one damped mode, then diagnose why a weak detector background systematically biases the inferred quality factor.

Know whether the detector reads field or energy

After a drive switches off, let a single cavity mode have complex analytic amplitude \(a(t)=a_0e^{-\kappa t/2}e^{-i\omega_0t}\) for \(t\ge0\). The energy is proportional to \(|a|^2\), giving \(U=U_0e^{-\kappa t}\). Its instantaneous decay rate \(-U'/U=\kappa\) implies

\[Q=\omega_0 U/P_\mathrm{loss}=\omega_0/\kappa.\]

A phase-sensitive receiver measuring field amplitude sees a time constant twice as long as the energy lifetime. Before fitting the data, ask how the measurement transducer converts the field into a reported number.

Fourier transforming the causal decaying amplitude gives an integral proportional to \(1/[\kappa/2-i(\omega-\omega_0)]\), up to the time convention. Its squared magnitude has half-power points at \(|\omega-\omega_0|=\kappa/2\). Therefore the full power linewidth in hertz is \(\Delta f=\kappa/(2\pi)\). A measurement of either the energy decay time \(\tau_U=1/\kappa\) or the spectral width can test the other without having to calibrate the absolute detector gain.

At \(f_0=2.0\) GHz and \(\tau_U=0.50\ \mu\mathrm s\), we obtain \(\kappa=2.0\times10^6\) s⁻¹, \(\Delta f\simeq318.3\) kHz and \(Q\simeq6283\). A field receiver would report an amplitude time constant of 1.0 μs. Substituting that time directly into \(Q=2\pi f_0\tau_U\) would double the apparent quality.

Derive the two-point fit with a detector offset

Let a power detector report \(S(t)=A e^{-\kappa t}+B\), with a constant background \(B>0\). In the absence of background two samples separated by \(\Delta t\) give

\[\widehat\kappa=\log[S(t)/S(t+\Delta t)]/\Delta t.\]

With background, the logarithmic derivative is

\[-\frac{d}{dt}\log S=\kappa\frac{Ae^{-\kappa t}}{Ae^{-\kappa t}+B}.\]

It starts below the true rate and tends to zero in the tail. A straight line fitted to late log data can therefore look impressively precise while overestimating the lifetime. Increasing the acquisition duration can worsen this bias if the entire record is forced into a straight-line model.

In the experiment set \(b=B/A=0.04\). A two-point fit from one true lifetime to two has dimensionless rate \(\log[(e^{-1}+0.04)/(e^{-2}+0.04)]\), approximately 0.844. Its apparent lifetime is about 18.5% high. The source, walls and coupling have not changed. Only the interpretation of detector output has changed. Move the start of the fit towards three lifetimes and inspect the increasing gap from the ideal log line.

Design a second independent inference

With three equally spaced, noiseless readings \(S_0,S_1,S_2\) of one exponential plus a constant, subtract consecutive values before taking a logarithm. If \(a=e^{-\kappa\Delta t}\), the differences are \(A'(1-a)\) and \(A'a(1-a)\), giving \(a=(S_1-S_2)/(S_0-S_1)\). This cancels the constant background. At an interval of one lifetime, a first signal of unit energy and background 0.04 gives approximately \(1.04,0.407879,0.175335\). Their ratio of differences recovers \(e^{-1}\). In a real noise floor two nearly equal readings make this division unreliable. Use multiple windows or fit the raw signal with a measured noise model.

Finite spectral resolution creates a separate challenge. Multiplying the measured field by a rectangular window of duration \(T\) convolves its spectrum with a sinc-like response of width of order \(1/T\). For the 318 kHz linewidth in the example, \(T=1\) μs gives frequency bins spaced by 1 MHz in a basic Fourier transform. Zero padding can interpolate its curve, but cannot restore the unmeasured late-time signal. A parametric fit may extract a sub-bin frequency or decay rate by using its model assumptions; its uncertainty then depends on signal-to-noise ratio and on whether the one-mode theory is adequate.

Check the single-mode model before refining its fit

If two nearby modes reach the same detector, their fields add before squaring. The result contains an interference term oscillating at their frequency difference on top of a decaying envelope. A scalar positive background cannot explain that alternating residual. Test by narrowing the excitation band, moving the pickup to a symmetry node of one mode, or examining a complex receiver's quadratures. A model with two exponentials has more degrees of freedom and can fit noise as well as signal; require consistency across independent records.

An honest linewidth report specifies the measured quantity, acquisition window, background treatment, coupling state, reference frequency and uncertainty. A fit to stored energy measures total loss. Inferring internal absorption alone additionally requires a known port coupling or a measurement that changes it separately, as in the course's cavity project.

Tutorial

A detector background is independently measured but subtracted too aggressively. What feature can appear in the logarithmic tail?

Work through the solution

The corrected signal can approach zero and cross below it. The logarithm then becomes undefined. Even before that point its apparent local slope can become arbitrarily large. Inspect the raw signed residual and its uncertainty instead of dropping nonpositive points without accounting for selection bias.

A second experiment doubles the peak stored energy while the absolute detector offset is fixed. What should happen to the shape of the normalised log tail?

Work through the solution

\(b=B/A\) halves. Background contamination becomes important later by about \(\tau_U\ln2\). A real change in the physical lifetime need not follow that shift when the response remains linear.

Can a passive resonator's intrinsic losses be determined from a single ring-down measured at one port?

Work through the solution

The observed decay is the sum of internal and external rates. A single accurately measured lifetime identifies their sum. A calibrated change in coupling or an independent power budget is needed to separate them.

Reconstructing a partially polarised electromagnetic wave

A detector averages enormous numbers of optical cycles. Its horizontal and vertical readings may be equal for a circularly polarised wave, a diagonal linearly polarised wave, or unpolarised light. Which additional intensities distinguish these preparations?

Start from what a polarising analyser measures

Take a quasi-monochromatic beam propagating in a fixed direction, resolved in transverse axes \(x,y\). Use complex field amplitudes with time factor \(e^{-i\omega t}\). Absorb common power and impedance factors into their units. The time- or ensemble-averaged coherency matrix \(J=\langle\boldsymbol E\boldsymbol E^\dagger\rangle\) has four real degrees of freedom because it is Hermitian. An analyser selecting the normalised complex state \(\boldsymbol a\) passes amplitude \(\boldsymbol a^\dagger\boldsymbol E\) and measures \(I_a=\boldsymbol a^\dagger J\boldsymbol a\). Thus every analyser projects the same matrix onto a distinct polarisation.

Choose \(S_0=J_{xx}+J_{yy}\), \(S_1=J_{xx}-J_{yy}\),

\[S_2=2\operatorname{Re}J_{xy},\]
\[S_3=-2\operatorname{Im}J_{xy}.\]

For this convention the state \((1,i)/\sqrt2\) has positive \(S_3\). Naming it by its explicit Jones vector avoids a handedness ambiguity between observer viewing directions. Inverting those definitions gives

\[J=\frac12\begin{pmatrix}S_0+S_1&S_2-iS_3\\S_2+iS_3&S_0-S_1\end{pmatrix}.\]

Horizontal and vertical linear analysers therefore give \((S_0\pm S_1)/2\). The \(+45^\circ,-45^\circ\) pair gives \((S_0\pm S_2)/2\). The circular pair \((1,\pm i)/\sqrt2\) gives \((S_0\pm S_3)/2\). Every pair sum recovers total intensity, providing an internal calibration check. Subtracting the complementary measurements cancels a common additive detector offset in each Stokes difference, though \(S_0\) still needs a dark correction.

Derive the physically allowed domain

Because \(I_a\ge0\) for every analyser, both eigenvalues of \(J\) are nonnegative. Solve its quadratic characteristic equation using the trace \(S_0\) and determinant \((S_0^2-S_1^2-S_2^2-S_3^2)/4\). The eigenvalues are \((S_0\pm|\boldsymbol S|)/2\), where \(\boldsymbol S=(S_1,S_2,S_3)\). Consequently \(P=|\boldsymbol S|/S_0\) lies between zero and one for a beam with nonzero intensity. A single fully polarised Jones state gives rank one and \(P=1\). An incoherent mixture of two orthogonal states of equal intensity has \(J=(S_0/2)I\) and \(P=0\).

Suppose a corrected data set gives \(I_x,I_y=70,30\); \(I_{+45},I_{-45}=65,35\); \(I_+,I_-=60,40\) in the same units. The pair sums agree at 100. Reconstructed parameters are \((100,40,30,20)\), giving \(P=\sqrt{2900}/100=0.539\). The eigenvalues are 76.93 and 23.07. Subtracting the smaller times the identity leaves a rank-one contribution of intensity 53.85 and an unpolarised remainder of intensity 46.15. This decomposition describes the observed second moments; several microscopic preparations can produce the same \(J\).

Predict a rotating analyser and identify its blind spot

For \(\boldsymbol a=(\cos\alpha,\sin\alpha)\), expanding the projection and using double-angle identities gives

\[I_\alpha=[S_0+S_1\cos2\alpha+S_2\sin2\alpha]/2.\]

A linear analyser alone is blind to \(S_3\), even when sampled at hundreds of angles. In the example the extrema are \(50\pm25\), with the maximum at \(\alpha=\frac12\operatorname{atan2}(30,40)=18.43^\circ\). The linear fringe visibility 0.50 is slightly below the total degree 0.539. Inserting a quarter-wave plate with Jones matrix \(\operatorname{diag}(1,-i)\) before the same analyser transforms \(S_2\) into \(S_3\) in the intensity formula. One can now obtain the previously hidden signed correlation from readings at \(45^\circ\) and \(135^\circ\).

The experiment prepares an adjustable polarised fraction with azimuth \(\psi\) and ellipticity angle \(\chi\), mixed with an unpolarised background. Its normalised Stokes vector is \(P(\cos2\chi\cos2\psi,\cos2\chi\sin2\psi,\sin2\chi)\). Make the unassisted intensity scan flat by choosing circular polarisation, then insert the fixed retarder virtually and predict the recovered difference. Setting \(P=0\) makes both scans flat. This comparison shows which measurement discriminates the two cases.

Tutorial on instrument design

A linear scan alone has \(I_{\max}=75,I_{\min}=25\). Give the range of total degrees of polarisation allowed and the maximum possible magnitude of \(S_3\).

Work through the solution

The linear magnitude is 50 and \(S_0=100\). Thus \(0.5\le P\le1\), and the positivity bound gives

\[|S_3|\le\sqrt{100^2-50^2}=86.60.\]

A circular analyser measurement fixes the remaining magnitude and sign.

An ideal beam contains 60 units of pure horizontal light and 40 units of unpolarised light. Compare its Stokes vector with a coherent superposition of horizontal and vertical components with intensities 80 and 20 and zero relative phase.

Work through the solution

The incoherent mixture has \((100,60,0,0)\) and \(P=0.6\). The coherent preparation has \((100,60,80,0)\) since \(2\sqrt{80\times20}=80\), and \(P=1\). Their horizontal and vertical readings coincide. A diagonal analyser gives 50 for the mixture and 90 for the coherent preparation.

All three measured component differences equal 70 at measured total 100. Can a physical beam have these parameters?

Work through the solution

They imply \(|\boldsymbol S|=70\sqrt3=121.2>S_0\) and a negative matrix eigenvalue. Check dark subtraction, gain calibration, alignment and whether the source changed between readings. A physical fit with stated uncertainties is required before interpreting the data as an optical state.

Further reading · ETH Zürich, Stenflo on coherency and Stokes parameters.

Two polarisations moving through a uniaxial crystal

A crystal can send two pulses in different directions even when their wavefronts have the same normal. The distinction emerges by applying the divergence condition to electric displacement and measuring energy flow with the Poynting vector.

A field transverse to the wavevector need not be the electric field

Let a transparent, nonmagnetic uniaxial medium have \(\boldsymbol\epsilon/\epsilon_0=\operatorname{diag}(n_o^2,n_o^2,n_e^2)\). The optic axis is \(z\); dispersion over the bandwidth under study is negligible. For a harmonic plane wave with wavevector in the \(xz\) plane, write \(\mathbf k=(k_x,0,k_z)\). Source-free Maxwell equations require \(\mathbf k\cdot\mathbf D=0\), \(\mathbf k\cdot\mathbf B=0\),

\[\mathbf k\times\mathbf E=\omega\mathbf B,\]
\[\mathbf k\times\mathbf H=-\omega\mathbf D.\]

Eliminating the magnetic field gives

\[\mathbf k\times(\mathbf k\times\mathbf E)+k_0^2(\boldsymbol\epsilon/\epsilon_0)\mathbf E=0,\]
\[k_0=\omega/c.\]

An electric field along \(y\) satisfies this system with \(k^2=k_0^2n_o^2\). This ordinary mode has transverse \(\mathbf E,\mathbf D\) and energy travels parallel to \(\mathbf k\). A second mode has \(\mathbf E\) in the \(xz\) plane; \(\mathbf D\) is transverse but generally not parallel to \(\mathbf E\).

Find the phase index and the direction of energy separately

The remaining two Cartesian equations form a matrix with diagonal \(k_0^2 n_o^2-k_z^2,\ k_0^2 n_e^2-k_x^2\) and off-diagonal elements \(k_xk_z\). Its determinant vanishes for nontrivial fields. Expanding cancels the fourth-order cross term and gives

\[\frac{k_x^2}{n_e^2}+\frac{k_z^2}{n_o^2}=k_0^2,\]
\[\frac1{n_{\rm ph}(\theta)^2}=\frac{\sin^2\theta}{n_e^2}+\frac{\cos^2\theta}{n_o^2},\]

where \(\theta\) is the angle from the optic axis to the wavevector. Along the axis both modes have the same index; perpendicular to it the extraordinary phase index is \(n_e\). For the latter mode choose transverse \(\mathbf D\propto(\cos\theta,0,-\sin\theta)\). Applying the inverse permittivity tensor gives

\[\mathbf E\propto(\cos\theta/n_o^2,0,-\sin\theta/n_e^2).\]

The magnetic field is along \(y\), so the energy flow angle \(\psi\) from \(z\) satisfies

\[\tan\psi=-\frac{E_z}{E_x}=\frac{n_o^2}{n_e^2}\tan\theta.\]

The group velocity obtained by differentiating \(\omega(\mathbf k)=c\sqrt{k_x^2/n_e^2+k_z^2/n_o^2}\) has the same direction in this nondispersive model. This independent construction is normal to the constant-frequency ellipse. At an interface it is the tangential component of \(\mathbf k\), fixed by phase matching, that selects the transmitted wavevector. The energy path can then diverge from the corresponding wave normal.

A crystal plate as a beam displacer and as a retarder

A normally incident beam with an oblique optic axis

Let \(n_o=1.50,\ n_e=1.60\) and let the plate normal make \(45^\circ\) to the optic axis. At normal incidence the phase normal is the plate normal for both modes. For the extraordinary wave \(\psi=\arctan(2.25/2.56)=41.3^\circ\). Relative to its wave normal the energy travels about \(-3.7^\circ\) toward the optic axis. Across a 10.0 mm thick plate the lateral displacement relative to the ordinary beam is approximately 0.65 mm. This describes propagation inside a parallel plate and neglects edge clipping.

A plate that turns linear input into circular output

Propagate perpendicular to the optic axis so both eigenmodes travel in the same direction. Their accumulated phase difference is \(\Delta=k_0(n_e-n_o)d\). Linear incident polarisation at \(45^\circ\) to the eigenaxes has equal amplitudes. When \(|\Delta|=\pi/2\) modulo \(2\pi\), those orthogonal components have a quarter-period phase difference and form circular polarisation, assuming equal transmitted amplitudes. At 600 nm with \(n_e-n_o=0.10\), the smallest such thickness is \(1.50\) μm. A larger multi-order plate can give the same retardance at this wavelength but responds more strongly to bandwidth and thickness errors.

Recover retardance from a pair of polarisers

Place the crystal axes at \(45^\circ\) to the input polariser and use a second polariser crossed with the first. Express the output field in the two crystal axes, then project onto the crossed analyser; its amplitude is proportional to \((e^{i\Delta}-1)/2\). Thus the transmitted fraction is \(\sin^2(\Delta/2)\). An arbitrary phase offset common to both modes disappears. A single intensity reading determines neither the sign of \(\Delta\) nor its full order. Varying thickness or scanning wavelength can resolve the branch; the material dispersion then enters the interpretation.

Predict the transverse displacement of a crystal plate

Choose principal indices 1.50 and 1.60 and a 45° wave normal. The extraordinary beam is displaced by about −0.65 mm through a 10 mm plate; the ordinary beam follows the normal. Swap the principal indices and compare the sign and magnitude of walk-off.

Problem sheet · use energy and phase observations

Infer birefringence from a walk-off angle

At \(\theta=45^\circ\), an extraordinary energy ray makes \(\psi=40^\circ\) to the optic axis. Assuming the same model, recover \(n_e/n_o\). Is the medium positive or negative uniaxial?

Work through the solution

The ratio is

\[\sqrt{\tan45^\circ/\tan40^\circ}=1.092.\]

The extraordinary principal index exceeds the ordinary one, a positive uniaxial material. A measurement referenced to the plate normal must first be converted to the angle from the optic axis used in the equation.

Calculate the contrast loss caused by angular misalignment

An ideal half-wave plate has its eigenaxis at angle \(\alpha\) to the input polariser. Keep the analyser crossed and find the intensity transmitted when the angle is \(40^\circ\) instead of \(45^\circ\).

Work through the solution

Projection into the crystal axes and back out gives

\[I/I_0=\sin^2(2\alpha)\sin^2(\Delta/2).\]

At half-wave retardance the factor from phase is unity, and the misaligned transmission is

\[\sin^2 80^\circ=0.970.\]

The reduction alone cannot distinguish angular error from a small error in retardance.

Further reading

What a momentum eigenstate means in a finite experiment

A detector never counts a perfectly sharp momentum eigenket. Derive continuum normalisation from a finite box, change the spectral measure from momentum to energy and predict the full evolution of a normalisable Gaussian packet.

Follow a normalised state as its allowed box grows

Consider a particle moving in one spatial dimension. A periodic box of length \(L\) is a mathematical model for an observation made far from any reflecting wall. The inner product is the integral of \(\psi^*(x)\chi(x)\) over the box. The momentum operator is \(-i\hbar\,d/dx\) with periodic boundary conditions. Integration by parts cancels its boundary form for periodic differentiable functions. Its normalised modes \(L^{-1/2}e^{ik_n x}\) have \(k_n=2\pi n/L\) and momenta \(p_n=\hbar k_n\). Their overlap is one if the integers coincide and zero otherwise. Increasing \(L\) reduces the spacing \(\Delta p=2\pi\hbar/L\) but also reduces the amplitude of each individual box mode at a fixed position. If one simply replaces the Kronecker delta by a Dirac delta while carrying over \(L^{-1/2}\), the units and probabilities will fail.

Let \(c_n\) be the unit-normalised amplitudes with \(\sum_n|c_n|^2=1\). For a smooth normalisable packet the probability in an interval \(dp\) has a limit \(|\phi(p)|^2 dp\). Thus \(c_n\simeq\sqrt{\Delta p}\,\phi(p_n)\). Substituting in the synthesis sum and using \(L\Delta p=2\pi\hbar\) produces

\[\psi(x)=\frac1{\sqrt{2\pi\hbar}}\int_{-\infty}^\infty e^{ipx/\hbar}\phi(p)\,dp,\qquad\]
\[\phi(p)=\frac1{\sqrt{2\pi\hbar}}\int_{-\infty}^\infty e^{-ipx/\hbar}\psi(x)\,dx .\]

The distributions \(\langle x|p\rangle=(2\pi\hbar)^{-1/2}e^{ipx/\hbar}\) have \(\langle p|p'\rangle=\delta(p-p')\). The delta acts under integration; \(\delta(0)\) has no finite interpretation as the probability for a detector. A physical probability is \(\int_{p_1}^{p_2}|\phi(p)|^2dp\). Changing to wave number gives

\[|\phi_k(k)|^2=\hbar|\phi(\hbar k)|^2.\]

A graph labelled density in \(k\) with a vertical axis copied directly from the momentum plot loses the Jacobian and in general ceases to normalise to one.

Change from momentum bins to energy bins

For a free particle \(E=p^2/(2m)\). Each positive energy has two distinct momenta \(p_\pm=\pm\sqrt{2mE}\). A detector measuring energy but not direction sums over these mutually orthogonal alternatives. Apply the ordinary change-of-variables rule on each monotone half-line:

\[w(E)=\frac{m}{\sqrt{2mE}}\left[|\phi(+\sqrt{2mE})|^2+|\phi(-\sqrt{2mE})|^2\right],\qquad E>0.\]

The factor \(m/|p|\) is \(1/|dE/dp|\), with units of momentum per energy. Measuring a finite energy interval around zero can have a density diverging as \(E^{-1/2}\) if \(\phi(0)\ne0\), yet the integrated probability is finite because \(\int_0^\delta E^{-1/2}dE=2\sqrt\delta\). The same effect appears in a box as relatively dense low-energy modes. Standing-wave box boundary conditions change the counting of travelling directions; include degeneracy once and use the appropriate mode spacing, rather than doubling both.

On an infinite line it is useful to introduce \(|E,+\rangle=\sqrt{m/|p|}\,|p\rangle\) at \(p>0\), and a corresponding negative branch. In the overlap,

\[\delta(p(E)-p(E'))=\delta(E-E')/|dp/dE|;\]

the two square-root factors give \(\delta(E-E')\). The resolution of identity contains \(\sum_{\pm}\int_0^\infty dE\,|E,\pm\rangle\langle E,\pm|\). Measuring energy while coherently manipulating the two degenerate directions requires keeping both amplitudes. Adding their probabilities is sufficient only for an instrument whose outcome identifies energy without mixing the directions before detection.

Integrate the free evolution of a Gaussian

Prepare a minimum-uncertainty wave packet centred at \(x_0\) with average momentum \(p_0\) and initial position standard deviation \(s\):

\[\psi(x,0)=(2\pi s^2)^{-1/4}\exp[-(x-x_0)^2/(4s^2)+ip_0(x-x_0)/\hbar].\]

Its squared modulus is a Gaussian with variance \(s^2\), which explains the factor four in the amplitude exponent. Complete the square in the Fourier integral to find a momentum probability Gaussian centred at \(p_0\) of variance \(\hbar^2/(4s^2)\). The initial state has zero symmetrised position–momentum covariance. Multiplying by a chirp factor \(\exp[i\kappa(x-x_0)^2]\) leaves its initial position density unchanged but changes momentum variance and covariance. A snapshot of one density does not determine its later free spread.

Each momentum component evolves by \(e^{-ip^2t/(2m\hbar)}\). Split \(p=p_0+q\). The constant term in \(p^2\) produces a common phase; the linear term shifts the envelope by \(p_0t/m\); the quadratic term changes the width. Carrying out the remaining Gaussian integral yields

\[|\psi(x,t)|^2=\frac{\exp[-(x-x_0-p_0t/m)^2/(2s_t^2)]}{\sqrt{2\pi}\,s_t},\]
\[s_t^2=s^2\left[1+\left(\frac{\hbar t}{2ms^2}\right)^2\right].\]

An independent route uses the Heisenberg operator \(x(t)=x(0)+p(0)t/m\). Its variance is \(s^2+(t/m)\langle\{\Delta x,\Delta p\}\rangle+(t/m)^2(\Delta p)^2\). Inserting zero covariance and the Gaussian momentum width reproduces \(s_t^2\). For a chirped packet the covariance term can be negative; momentary narrowing during free evolution is consistent with uncertainty because momentum width and the phase correlation must be included. The density integral stays one, so spreading lowers the height of the peak without removing particles.

Take a model atom of mass \(1.44\times10^{-25}\) kg prepared with \(s=1.00\,\mu\mathrm m\). Its spread time \(t_s=2ms^2/\hbar=2.73\) ms. At \(t=t_s\) the standard deviation is 1.41 μm. With mean velocity 2.00 mm/s its mean has advanced 5.46 μm. At long flight times \(s_t\simeq t\Delta p/m\). Measuring position after a known long flight therefore maps the momentum distribution for this free packet. At \(0.5t_s\) the neglected initial position variance is still dominant, so the same inference would substantially overestimate \(\Delta p\).

A detector window and a Fourier grid do different jobs

Suppose the position-sensitive detector has a Gaussian point-spread function of width \(d\). The measured density is a convolution of the true density with that response if detections are independent and gain is uniform. Gaussian variances then add:

\[s_{\rm obs}^2=s_t^2+d^2.\]

This broadening belongs to the observation model; it does not increase the particle's momentum spread before the measurement. For \(d=1.20\,\mu\mathrm m\) at \(t=t_s\), the observed standard deviation becomes \(1.85\,\mu\mathrm m\). A fit to a single image with unknown \(d\) cannot disentangle the two contributions. A sequence of flight times constrains the coefficient of \(t^2\) independently of a fixed instrument width.

A discrete Fourier propagation represents a periodic interval sampled at spacing \(\Delta x\). Its wave-number spacing is \(2\pi/L\), and the highest resolved wave number is order \(\pi/\Delta x\). Enlarging \(L\) at fixed \(\Delta x\) samples the momentum profile more finely and delays periodic wraparound. Reducing \(\Delta x\) at fixed \(L\) raises the bandwidth without moving the periodic boundary. Either operation alone can leave the other error intact. A norm-preserving FFT propagator can therefore return a perfectly normalised wave packet that has wrapped through an unphysical boundary or whose carrier momentum has aliased. Compare the phase, group velocity and width against independent formulas, then refine the two scales separately.

Why boundary conditions are part of a momentum observable

The expression \(p=-i\hbar\,d/dx\) does not by itself specify a complete operator. On a finite interval \([0,L]\), integrate two sufficiently smooth square-integrable functions by parts:

\[\langle f,pg\rangle-\langle pf,g\rangle=-i\hbar[f^*(x)g(x)]_{0}^{L}.\]

A symmetric domain makes this boundary form vanish for every pair in the domain. A self-adjoint operator additionally has the same domain as its adjoint. This distinction matters for a physical generator of unitary translations and for assigning sharp spectral outcomes. Imposing a real or imaginary matrix representation in a finite basis can conceal boundary conditions that become essential as the basis is enlarged.

For a ring allow quasi-periodicity \(g(L)=e^{i\theta}g(0)\) with fixed \(\theta\) common to all functions in the domain and square-integrable first derivative. Then the boundary form vanishes. Conversely, for an adjoint candidate \(f\) the requirement that it vanish for all possible \(g(0)\) forces \(f(L)=e^{i\theta}f(0)\), so the same condition reappears. Solving \(p g=pg\) yields the momenta \(p_n=\hbar(2\pi n+\theta)/L\). Thus boxes with precisely the same local differential expression have momentum spectra shifted by an externally fixed phase. In a physically realised ring such a phase can encode a magnetic flux through a gauge-transformed boundary condition; a gauge consistent with that interpretation must also be used in the Hamiltonian and physical momentum.

Compare with forcing \(g(0)=g(L)=0\) as in a hard-wall well. The boundary form vanishes for all \(f,g\) satisfying both zero conditions, so the derivative is symmetric there. But the adjoint boundary form vanishes for arbitrary endpoint values of \(f\) when \(g\) vanishes at both ends. Consequently this two-zero derivative domain is smaller than its adjoint domain. There is no ordinary rigid translation that carries every state of a hard-wall interval back into that same interval without assigning what happens at its boundary. Meanwhile the kinetic energy \(-\hbar^2d^2/(2m\,dx^2)\) with suitable Dirichlet domain is self-adjoint and has a well-defined discrete spectrum. The symbol \(p^2/(2m)\) in a Dirichlet well does not turn its first derivative with the same two endpoint conditions into a self-adjoint sharp momentum observable.

A release-and-detect experiment makes this distinction concrete. Prepare the first Dirichlet state \(\sqrt{2/L}\sin(\pi x/L)\) supported in \(0<x<L\), then remove the walls suddenly and measure momentum on the full line. Its momentum wavefunction is the Fourier transform of the spatial function extended by zero outside. Multiplying the exponential and sine and integrating gives a continuous amplitude proportional to \([1+e^{-ipL/\hbar}]/[(\pi/L)^2-(p/\hbar)^2]\). The apparent singularities at \(p/\hbar=\pm\pi/L\) are removable because the numerator also vanishes. It is a mistake to predict two delta peaks by replacing the standing wave with the sum of two infinite plane waves. The finite support multiplies that sum by a spatial window and broadens both momentum components.

The mean momentum for this real function is zero. Its second moment after release is \(\hbar^2\int|\psi'|^2dx=\pi^2\hbar^2/L^2\), consistent with the original kinetic energy. Thus a continuous released momentum distribution can have an rms momentum whose square exactly recovers a discrete energy of the original bounded system. This is a useful quantitative example where the equality of moments across two measurement procedures does not imply equality of their full spectral probability distributions. Adding a short laboratory impulse to every particle after release should translate the whole distribution by the corresponding momentum kick, preserving its width. That response provides an independent check on a momentum detector's sign and scale.

Derive the free propagator with a convergent limiting prescription

Partitioning the free unitary into momentum eigenstates produces its position kernel

\[K(x,t;x',0)=\frac1{2\pi\hbar}\int_{-\infty}^{\infty}\exp\left[\frac{i}{\hbar}\left(p(x-x')-\frac{p^2t}{2m}\right)\right]dp .\]

It is oscillatory rather than absolutely integrable. Define it by first damping \(e^{-\varepsilon p^2}\), evaluating a convergent Gaussian and then taking \(\varepsilon\downarrow0\) on smooth normalisable test packets. Completing the square in the exponent gives, for \(t>0\),

\[K=\sqrt{\frac{m}{2\pi i\hbar t}}\exp\left[\frac{im(x-x')^2}{2\hbar t}\right].\]

The phase convention of the square root for positive time follows continuously from the regularised Gaussian. The units are inverse length so \(\psi(x,t)=\int K(x,t;x',0)\psi(x',0)\,dx'\) has the same units as the initial wavefunction. As \(t\to0^+\), the kernel does not approach a finite spike pointwise. Its increasingly fast oscillations across \(x'\) cancel except near \(x'=x\), recovering the initial state in the appropriate strong or distributional sense. For a constant initial amplitude one may recover unity formally, but such an amplitude on the full line is itself not a normalised test state.

Two checks involve no wave packet fitting. Inserting two kernels for \(t_1,t_2\) and integrating over an intermediate position gives the kernel for \(t_1+t_2\), either by another Gaussian integration or, more directly, by composing the momentum phase factors. Complex conjugation and reversing the time arguments yield the inverse evolution. Neither statement holds for an arbitrary choice of magnitude prefactor assigned merely to obtain the correct phase. In Fourier numerics the corresponding checks are unit norm after repeated evolution and recovery of the original sampled complex state after a forward followed by backward propagation. These are necessary algorithm checks, even though a periodic or aliased computational model can still satisfy them exactly.

This kernel also clarifies the long-time momentum mapping. Factor \(e^{im x^2/(2\hbar t)}\) from \(K\) and identify the Fourier transform of \(e^{imx'^2/(2\hbar t)}\psi(x',0)\) evaluated at \(p=mx/t\). If the occupied initial region is narrow enough that \(mx'^2/(2\hbar t)\) varies little across it about the selected origin, the extra phase can be neglected and

\[|\psi(x,t)|^2\simeq\frac mt\left|\phi\!\left(\frac{mx}{t}\right)\right|^2 .\]

The factor \(m/t\) is the Jacobian \(dp/dx\). When the initial packet is displaced, use a suitable shifted origin or account for the induced linear phase explicitly. This derivation applies well beyond Gaussians and gives a scale for testing the approximation before interpreting a flight image as a momentum histogram. The quadratic residual phase provides the matter-wave analogue of the near-field correction in diffraction.

Distinguish a detector crossing from a snapshot in space

A detector counts particles passing through an aperture over time. Its signal is related to flux, whereas a camera image of identical preparations at one time probes a position distribution. For a one-dimensional free wavefunction the continuity equation is \(\partial_t|\psi|^2+\partial_xj=0\) with \(j=(\hbar/m)\operatorname{Im}(\psi^*\partial_x\psi)\). Integrating over the region \(x<X\) gives the change in probability to the left of a fixed plane. If there is no flux at negative infinity, the net integrated current through \(X\) equals the reduction in that probability. A positive-reading counter with absorption is a more detailed instrument and cannot in general be identified with a signed current in the presence of reflected waves or interference.

For a minimum-uncertainty Gaussian initially at \(x_0\), the exact phase in the freely expanding envelope has a quadratic term. Differentiating the phase gives the local velocity entering current,

\[\frac{j(x,t)}{|\psi(x,t)|^2}=\frac{p_0}{m}+\frac{t}{t_s^2+t^2}\left(x-x_0-\frac{p_0t}{m}\right).\]

At the centre this equals the group velocity \(p_0/m\), but ahead of the centre it is larger and behind it smaller. A single constant velocity multiplying density is inadequate for a significantly spreading packet. For the earlier atom at \(t=t_s\), one current-standard-deviation distance ahead corresponds to \(1.41\,\mu\mathrm m\) and the additional speed is about \(0.259\) mm/s. The trailing side gives the opposite correction. Direct differentiation of its Gaussian density verifies that this current satisfies continuity. A code reproducing \(s_t\) but evolving the wrong complex phase may fail this current test; judging an entire propagation by the changing width alone would miss the error.

A useful inverse question is whether two time-of-flight images suffice to recover an unknown complex wavefunction. In the long-time limit the image yields \(|\phi(p)|^2\), which contains no direct momentum-dependent phase. Translation of the initial wave packet changes \(\phi(p)\) by a linear phase, leaving the momentum density unchanged. Complex conjugate or chirped preparations can also share particular intensity records. Additional calibrated evolution, known reference interference or structural assumptions can provide phase information. Even an exact free propagator only defines the forward map; its invertibility on complex amplitudes does not imply intensity-only data identify every possible input. The experiment must specify which class of preparations and which measurement settings render the desired parameters estimable.

Track a continuous superposition through focus

Change a position-momentum correlation and compare the full packet width with an initially unchirped packet. A narrow width at one time does not determine its subsequent spread.

Plan an FFT comparison using physical position and momentum resolution

A grid propagator can track the same packet analytically solved earlier, then carry over its verified conventions to less elementary potentials. A common trap is to regard the number of points \(N\) as a single accuracy parameter. Define a periodic interval of physical length \(L=N\Delta x\). Discrete Fourier modes have \(k_j=2\pi j/L\), with negative wave numbers represented by negative indices after reordering. Their spacing is \(\Delta k=2\pi/L\); the largest distinct magnitude is close to \(\pi/\Delta x\). A narrow structure in momentum requires large \(L\). A high carrier momentum requires small \(\Delta x\). These conditions can fail independently even when the norm stays exactly one.

If \(\psi_l=\psi(x_l)\) is a sampled wavefunction in inverse square-root metres and the forward transform sums without \(1/N\), the approximated continuum \(k\)-amplitude is

\[\phi_k(k_j)\simeq\Delta x\,\sum_l\psi_l e^{-ik_jx_l}/\sqrt{2\pi}.\]

The phase includes the physical coordinate origin adopted for the grid. Parseval then gives

\[\Delta k\sum_j|\phi_k(k_j)|^2=\Delta x\sum_l|\psi_l|^2.\]

A library returning a unitary discrete transform instead assigns a factor \(1/\sqrt N\) to both directions; multiplying its output by \(\sqrt{\Delta x/\Delta k}\) converts sample units. Plotting a library output directly against physical momentum without these scale factors is especially misleading when comparing two meshes. Total discrete \(\ell^2\) norm and continuum probability density are different normalisations of the same samples.

For the atom of mass \(1.44\times10^{-25}\) kg, \(s=1.00\) μm and \(v_0=2.00\) mm/s,

\[k_0=mv_0/\hbar=2.73\,\mu\mathrm m^{-1},\]
\[\Delta k_{\rm rms}=1/(2s)=0.50\,\mu\mathrm m^{-1}.\]

A box 80 μm wide gives spacing \(0.0785\,\mu\mathrm m^{-1}\), about 6.4 modes per rms momentum width. With \(N=256\), grid spacing is 0.3125 μm and Nyquist wavenumber is \(10.05\,\mu\mathrm m^{-1}\), exceeding \(k_0+5\Delta k_{\rm rms}=5.23\,\mu\mathrm m^{-1}\). This comfortably samples the initial carrier distribution. It is still necessary to check that the envelope remains inside the periodic box at the desired final time.

At \(t=10\) ms the packet centre has moved 20 μm and \(s_t\simeq3.80\) μm. Starting at the centre of an interval spanning \(-40\) to \(40\) μm, its five-standard-deviation front approaches \(39\) μm and begins testing the boundary margin. At 20 ms the centre alone reaches the periodic boundary. A perfectly unitary calculation will show it reappearing on the opposite side. This is correct for a ring and incorrect for a free-space flight image. Enlarging \(N\) while keeping the same \(L\) improves the Nyquist limit but does nothing to postpone this crossing. An open-boundary absorber can delay reflected artefacts but attenuates norm; a lost norm in that model should be compared with counted escape rather than naively enforced to zero.

Infer displacement and speed from a wrapped packet without mistaking periodicity for reflection

A code on a periodic box of length 80 μm reports a sharp packet peak at \(+35\) μm in one frame and \(-36\) μm in the next frame 4.50 ms later. Find a consistent uniform drift and identify the ambiguity if no speed prior is available.

Derive and check the result

The smallest forward displacement is \(+9\) μm after adding one full box length to the second position. It corresponds to \(2.00\) mm/s and agrees with the earlier preparation. Direct subtraction without unwrapping would give \(-71\) μm, or \(-15.8\) mm/s, an apparent reversal. All displacements \(9+80n\) μm for integer \(n\) yield the same wrapped pair, so the frames alone cannot identify the number of turns. A momentum measurement or a bound on speed relative to frame spacing resolves the branch. For an extended packet crossing a seam, use a periodic circular moment such as \(\langle e^{2\pi i x/L}\rangle\) so an ordinary spatial mean does not spuriously jump toward the box centre. If that circular moment is nearly zero, even its angular centre is ill-defined and a full density comparison is preferable.

Tutorial · design a momentum measurement

Distinguish an unresolved line from a finite-width packet

A periodic calculation of length \(L=100\,\mu\mathrm m\) contains mode \(n\). A detector bins momentum in intervals \(1.0\times10^{-29}\,\mathrm{kg\,m/s}\). How many box-mode spacings fit into a bin? What changes if the box length doubles at fixed physical packet?

Work through the solution

Here \(\Delta p=h/L=6.626\times10^{-30}\,\mathrm{kg\,m/s}\), so the detector bin spans about 1.51 spacings. The precise number of grid points falling within a bin depends on its endpoints. Doubling \(L\) gives roughly 3.02 spacings per bin. Each corresponding coefficient squared decreases approximately in proportion to \(\Delta p\), while the number included increases. The total probability should approach a stable integral on a progressively finer grid. If a graph compares \(|c_n|^2\) across the boxes, divide by the corresponding \(\Delta p\) before calling the ordinate a continuum density.

Calculate a threshold energy interval without evaluating a delta at zero

A packet's momentum density is nearly constant \(w_0\) over \(-p_c<p<p_c\). Obtain the probability for \(0<E<E_c=p_c^2/(2m)\) by two different integrations. What changes when only positive-momentum particles reach the counter?

Work through the solution

Direct integration in momentum gives \(2p_c w_0\). In energy the two branches contribute \(2mw_0/\sqrt{2mE}\). Its integral gives \(4mw_0\sqrt{E_c}/\sqrt{2m}=2p_cw_0\) as required. A positive-direction selector halves this particular probability when applied to the original ensemble. If the entire subsequent experiment is renormalised to the selected particles, divide again by the total positive-momentum probability. Those two reported probabilities correspond to different conditioning and should be labelled explicitly.

Infer the packet width from two images

The model atom has an initial measured width 1.56 μm and a width 1.85 μm after 2.73 ms. Assume a time-independent Gaussian instrument response and a freely evolving unchirped minimum-uncertainty state. Infer \(s\) and \(d\), and identify an additional check.

Work through the solution

Subtract squared widths to remove the detector:

\[s_{\rm obs}(t)^2-s_{\rm obs}(0)^2=\hbar^2t^2/(4m^2s^2).\]

The observed difference is about \(0.99\,\mu{\rm m}^2\), giving \(s\simeq1.0\,\mu\mathrm m\) and \(d=\sqrt{s_{\rm obs}(0)^2-s^2}\simeq1.2\,\mu\mathrm m\), within rounding. A third flight time tests the predicted quadratic in \(t\). A term linear in time would point to a nonzero initial correlation or to measurement drift. Independent calibration of the point-spread function distinguishes those interpretations from a nonminimum momentum width.

Further reading

From a finite pulse to a continuum transition rate

Switch a weak perturbation on for a measured duration. Its Fourier transform determines the amplitude of a discrete transition. Summing over a dense set of final states reveals where a time-independent transition rate comes from and where it fails.

Remove the known free evolution before approximating

Let \(H_0|n\rangle=E_n|n\rangle\) and \(H(t)=H_0+V(t)\). Expand \(|\psi(t)\rangle=\sum_n c_n(t)e^{-iE_n t/\hbar}|n\rangle\). Substituting into the time-dependent Schrödinger equation cancels the free phase derivatives and leaves an exact equation \(i\hbar\dot c_f=\sum_n e^{i(E_f-E_n)t/\hbar} V_{fn}(t)c_n(t)\). Suppose the initial state is \(|i\rangle\) and the perturbation is appreciable only between \(0\) and \(T\). Iterating the integral equation once, replacing \(c_n(t)\) on the right by \(\delta_{ni}\), yields

\[c_f^{(1)}(T)=-\frac i\hbar\int_0^T e^{i\omega_{fi}t}V_{fi}(t)\,dt,\]
\[\omega_{fi}=(E_f-E_i)/\hbar .\]

For \(f\ne i\) the leading transition probability is \(|c_f^{(1)}|^2\). It is second order in the perturbation even though the amplitude is first order. Conservation of total probability to this order requires a second-order correction to the initial amplitude. Simply appending all positive final probabilities while keeping the initial probability exactly one would fail that test. The approximation is controlled when total probability removed from the initial state is small over the observation duration and higher-order pathways are negligible.

Let the resonant component of a drive have matrix element \(V_{fi}(t)=v e^{-i\omega t}\) for \(0<t<T\). For a real cosine perturbation the two exponentials each carry half the real peak amplitude, so \(v\) refers to just the near-resonant part. Define \(\Delta=\omega_{fi}-\omega\). Direct integration gives

\[P_f^{(1)}=\frac{|v|^2T^2}{\hbar^2}\operatorname{sinc}^2(\Delta T/2),\]
\[\operatorname{sinc}x=\sin x/x .\]

At resonance the amplitude grows linearly in time while its phase remains coherent. A detuned contribution winds around in the complex plane and largely cancels. The first zeros occur at ordinary detuning \(\pm1/T\) in hertz. The full width at half height is approximately \(0.886/T\) in ordinary frequency since \(\sin x/x=1/\sqrt2\) at \(x\simeq1.3916\). Doubling duration quadruples the line-centre probability for one final state but halves the linewidth, a distinction central to interpreting a continuum rate.

Sum over final states before taking a long-time limit

A large box provides a discrete set of final levels with spacing \(\delta E\); at fixed finite time many can lie inside the pulse's energy bandwidth. Let \(\rho(E)\) be the density of the accessible final states per joule, including degeneracy exactly once. Replace the sum by an integral with \(E_*=E_i+\hbar\omega\):

\[P_{\rm out}\simeq\frac{T^2}{\hbar^2}\int dE\,\rho(E)|v(E)|^2\operatorname{sinc}^2\left[\frac{(E-E_*)T}{2\hbar}\right].\]

If \(\rho|v|^2\) changes little across the dominant width and the line is well away from thresholds, take it outside the integral. Substitute \(u=(E-E_*)T/(2\hbar)\), and use \(\int_{-\infty}^{\infty}(\sin u/u)^2du=\pi\). The area of the squared Fourier transform grows linearly, giving

\[\Gamma=\frac{P_{\rm out}}T\simeq\frac{2\pi}{\hbar}|v(E_*)|^2\rho(E_*).\]

The identity for the sinc area also follows by Parseval from the energy in the rectangular time window. This is Fermi's golden rule with \(\rho\) per energy. If a supplied density is per unit angular frequency,

\[\rho_\omega=\hbar\rho_E;\]

failing to change that measure introduces a factor of \(\hbar\). The units are a strong check: energy squared times states per energy divided by action is inverse seconds.

Several limits have been taken in a definite order. The perturbation lasts long enough to resolve the scale on which \(\rho|v|^2\) varies but short enough that many levels still fit in its bandwidth. A window of times must exist between a reservoir correlation time and a recurrence time of order \(2\pi\hbar/\delta E\). In addition \(\Gamma T\ll1\) for the first-order depletion argument. Taking \(T\to\infty\) at fixed finite box instead resolves individual levels and can produce coherent oscillations or recurrences. Extending the constant rate to a full exponential decay uses a further memoryless approximation and renewed weak transitions of the remaining population. A linear short-time fit by itself does not establish exponential dynamics at every time.

Keep matrix elements and density normalisation consistent

For illustration choose \(|v|=5.00\times10^{-6}\) eV and \(\rho=20.0\ \mathrm{eV^{-1}}\) for box-normalised accessible modes dense enough on the pulse scale, giving \(\Gamma\simeq4.77\times10^6\,\mathrm{s^{-1}}\) as a formal product. But the implied mean level spacing \(1/\rho=0.050\) eV corresponds to a recurrence scale of only \(8.27\times10^{-14}\) s. Using a nanosecond pulse with this literal finite density violates the continuum criterion, irrespective of how small \(\Gamma T\) looks. This numerical mismatch is a useful trap: reproducing a golden-rule number to many digits does not ensure the system supports irreversible decay in the chosen time range.

Now enlarge the quantisation volume by \(10^6\) for continuum-normalised physical coupling. The number of accessible states per energy grows by \(10^6\), while each squared matrix element shrinks by \(10^6\) for a localised initial state and individually unit-normalised extended final states. The same product gives the same \(\Gamma\), but spacing is now \(5.0\times10^{-8}\) eV and the recurrence scale 82.7 ns. At \(T=2.0\) ns, \(\Gamma T=0.00954\) and roughly \(h/(T\delta E)\simeq41\) spacings fit up to the first positive zero. Whether density and coupling are locally smooth on that bandwidth remains an additional condition. The scaling removes explicit box dependence from a physical rate while clarifying why direct sums at finite volume can require larger spaces.

Use phase space to predict the shape of a continuum edge

For free relative motion in three dimensions, count single scalar internal channels in a cubic periodic volume \(\mathcal V\). One state occupies volume \((2\pi)^3/\mathcal V\) in wave-vector space. The shell between \(k,k+dk\) thus contains \(\mathcal V4\pi k^2dk/(2\pi)^3\). From \(E=\hbar^2k^2/(2m)\) it follows that \(\rho(E)=\mathcal V m k/(2\pi^2\hbar^2)\), which vanishes like \(\sqrt E\) at threshold. In one dimension the corresponding free density diverges like \(1/\sqrt E\); the geometrical shell measure is different. A threshold suppression observed in one spectrum could come from available states, the coupling matrix element, or both.

If a local transition couples chiefly to a final orbital partial wave \(l\), its regular low-\(k\) free radial factor near the source scales as \(k^l\) when the potential is sufficiently short ranged and no threshold resonance changes the law. Squaring and multiplying by the three-dimensional density gives

\[\Gamma_l\propto k^{2l+1}\propto E^{l+1/2}.\]

For a \(p\)-wave channel doubling the excess energy increases this ideal rate by \(2^{3/2}=2.83\). Long-range Coulomb fields alter the final-state radial behaviour and can invalidate the short-range threshold power. Very close to any edge a finite pulse straddles energies where the density changes rapidly or vanishes. Replace the local golden-rule product by the finite-window integral to model the measured onset.

Compare pulse shapes at equal area and equal energy

The rectangular pulse is useful because its Fourier transform is elementary. Its abrupt start and end also generate sidelobes that can excite nearby unwanted transitions. For a general narrowband drive write its resonant matrix element \(v(t)e^{-i\omega t}\). First order gives

\[P_f=|\int v(t)e^{i\Delta t}dt|^2/\hbar^2.\]

At zero detuning only the complex pulse area \(\int v(t)dt\) matters. After summing over a flat continuum, Parseval gives \(\int P_f(\Delta)d\Delta=(2\pi/\hbar^2)\int|v(t)|^2dt\), so it is the temporal integral of squared coupling that controls total spectral weight. Two pulses with the same area can have different continuum probabilities; two with the same integrated intensity can have different resonant peak heights.

For a Gaussian envelope \(v(t)=v_0e^{-t^2/(2\tau^2)}\) on the full line, complete the square in its Fourier integral. The amplitude is \(v_0\sqrt{2\pi}\tau e^{-\Delta^2\tau^2/2}\), so the transition profile has no sidelobes and has full half-height angular width \(2\sqrt{\ln2}/\tau\). The time intensity is \(|v_0|^2e^{-t^2/\tau^2}\), with temporal full half-height width \(2\sqrt{\ln2}\tau\). Multiplying this by the ordinary-frequency full width gives

\[2\ln2/\pi=0.441.\]

Replacing an amplitude width by an intensity width changes that product by \(\sqrt2\); specifying the plotted quantity is necessary when comparing a spectrum with temporal photodetector data.

Take a Gaussian with \(\tau=0.50\) ms. Its spectral intensity full width is \(530\) Hz and pulse intensity full temporal width \(0.833\) ms. An unwanted line 1.0 kHz away receives a relative first-order probability \(e^{-(2\pi1000\tau)^2}\simeq5.17\times10^{-5}\). A nominally same-duration rectangular pulse may place an ideal zero near some precisely chosen detuning, but neighbouring frequencies generally see sidelobes. Which pulse gives smaller unwanted excitation depends on what quantity is fixed, where the extra lines lie and how much uncertainty there is in their positions. A shaped envelope can suppress spectral leakage without improving every possible resolution metric.

A pair of pulses illustrates how coherently adding amplitudes differs from broadening a single envelope. Let identical, short pulses of area \(A\) be separated by start-time difference \(T_s\), and let the second have a controlled drive phase \(\phi\). At a detuning small compared with each pulse bandwidth, the amplitude is proportional to \(A[1+e^{i(\Delta T_s+\phi)}]\). Its squared magnitude has fringes \(2|A|^2[1+\cos(\Delta T_s+\phi)]\) inside the broader single-pulse line. Their ordinary-frequency spacing \(1/T_s\) can be much smaller than the inverse individual pulse duration. Randomising the relative phase removes fringes while keeping the two single-pulse energies unchanged. The observed fine spectral structure is therefore a measurement of coherent time separation as well as energy difference.

Derive depletion and the energy shift from the same kernel

The first-order rate gives initial population loss in a useful time window. To see which extra assumptions allow exponential decay, retain a single initial discrete level coupled to many initially empty final levels with time-independent couplings \(v_f\) in a rotating frame. Let \(c_i(0)=1,\ c_f(0)=0\). In the interaction picture \(\dot c_f=-(i/\hbar)v_f e^{i\omega_{fi}t}c_i(t)\). Integrate this equation exactly in terms of the unknown \(c_i\) and insert the result in its partner equation for \(\dot c_i\). Assuming final levels do not couple directly to one another gives

\[\dot c_i(t)=-\int_0^t K(t-t')c_i(t')\,dt',\]
\[K(\tau)=\hbar^{-2}\sum_f |v_f|^2e^{-i\omega_{fi}\tau}.\]

No irreversibility has been assumed in this elimination. The previous discrete amplitudes are encoded in a memory kernel and can feed back into the initial level. At very short times \(c_i(t)\simeq1-K(0)t^2/2\) when the second moment is finite, yielding a quadratic survival loss. At long times a sharply structured or bounded continuum can produce nonexponential decay. A finite number of exactly known final levels evolves unitarily under the full Hamiltonian and can show recurrences; treating the memory as identically zero after any arbitrarily short interval would discard this possibility.

When the spectral coupling varies slowly over the line and extends across a sufficiently broad band, phase cancellation makes \(K(\tau)\) decay over a correlation time \(\tau_c\). For \(\tau_c\) short relative to changes in \(c_i\), write \(c_i(t-\tau)\approx c_i(t)\) inside its memory integral after the initial transient, and extend its upper limit to infinity. The regulated integral \(\int_0^\infty e^{-i\omega\tau-\eta\tau}d\tau=(\eta+i\omega)^{-1}\) tends to \(\pi\delta(\omega)-i\,\mathcal P(1/\omega)\) as a distribution. Its real part gives

\[\dot c_i=-\Gamma c_i/2+\cdots,\]

with the same golden-rule population rate \(\Gamma\). The imaginary part gives a coherent energy shift proportional to \(\mathcal P\sum_f |v_f|^2/(E_i-E_f)\), requiring the physical bandwidth and a consistent bare energy. This shows how an absorptive linewidth and a dispersive shift can emerge from different parts of the same elimination, without claiming a perfectly flat infinite continuum supplies a physically meaningful absolute shift.

For a symmetric model with constant spectral strength inside \(-W<\omega_{fi}<W\), the kernel is proportional to \(\sin(W\tau)/\tau\). Narrowing the band increases its memory time and can delay the onset of an approximately constant rate. Moving the discrete level close to a band edge also removes the cancellation between positive and negative detunings responsible for a vanishing symmetric shift. An experiment that varies the carrier across such an edge should fit the full finite-window spectrum before inferring a time-independent linewidth or level shift. A numerically cheap sum over known discrete final energies provides a check: double the spectral cutoff, halve level spacing and track the early quadratic regime separately from any intermediate exponential segment.

Ask whether frequent projective tests inhibit a transition

For an initial pure state with finite energy variance under a time-independent \(H\), expand the survival amplitude \(A(t)=\langle i|e^{-iHt/\hbar}|i\rangle\) to second order. The linear term \(-it\langle H\rangle/\hbar\) is a phase. Squaring gives

\[P_i(t)=1-(\Delta H)^2t^2/\hbar^2+O(t^3),\]

with still higher-order control depending on available moments. Define \(t_Z=\hbar/\Delta H\). In the model with one initial level coupled only off-diagonally to the final levels, \((\Delta H)^2=\sum_f|v_f|^2\), agreeing with the memory-kernel expansion. If the needed moments diverge in an idealised continuum, this short-time expansion requires a physical high-frequency regularisation.

Now make ideal instantaneous projective tests of whether the system is still in \(|i\rangle\) every \(\tau=T/N\), selecting only histories that have passed every test. Conditional on survival, each projection prepares exactly the same initial state. The joint survival probability is \(P_i(\tau)^N\simeq[1-(T/Nt_Z)^2]^N\to1\) as \(N\to\infty\) for fixed total duration \(T\). This is a mathematically precise limiting model of the quantum Zeno effect. It is not obtained by simply looking at a stored record more often after a single final measurement; the successive physical interventions reset the conditional state.

With a resonantly coupled two-state Hamiltonian \(H=v\sigma_x\), the survival against a single interval is \(\cos^2(v\tau/\hbar)\). Choose \(vT/\hbar=\pi/2\); unobserved survival at \(T\) is zero. For ten equally spaced perfect tests the joint survival is

\[\cos^{20}(\pi/20)=0.7805.\]

If the instrument has 2% independent loss per successful test, the recorded joint fraction falls to

\[0.7805(0.98)^{10}=0.638.\]

A finite-duration detector may also change \(H\) or broaden spectral coupling rather than implement an instantaneous projection. The ideal repeated-measurement result gives a comparison baseline, while predicted observed counts must include the physical instrument and conditioning.

Derive the sweep-rate scale for a transition through resonance

For a chirped weak drive let its instantaneous detuning from one discrete transition change linearly, \(\Delta(t)=\dot\Delta\,t\), crossing zero at the middle of a long pulse. The phase accumulated in the first-order integral is \(\int^t\Delta(t')dt'=\dot\Delta\,t^2/2\), not \(\Delta(t)t\). For approximately constant coupling \(v\) around the crossing and sufficiently far endpoints the oscillatory Gaussian integral gives \(|c_f^{(1)}|^2\simeq2\pi|v|^2/(\hbar^2|\dot\Delta|)\). A slower passage accumulates a larger resonant amplitude, but this weak-coupling formula cannot exceed probability one. At large transfer the full two-level avoided-crossing dynamics replaces it.

For \(|v|/\hbar=2\pi\times200\) Hz and an ordinary-frequency sweep \(d(\Delta/2\pi)/dt=10^8\) Hz/s, the estimate is \(0.0158\). Changing only the sign of the sweep gives the same first-order probability in this symmetric idealisation, while the phase of the transition amplitude changes. Coherently driving a second passage can convert that phase difference into an observable interference pattern. Missing endpoints, asymmetric pulse shaping and additional nearby lines can spoil the simple symmetry. Comparing both sweep directions and checking that the result scales as inverse speed over a low-transfer range are concrete tests of the stationary-phase approximation instead of assuming every apparent line crossing signifies complete adiabatic transfer.

Separate a transition frequency from coherence loss

Vary detuning and shot-to-shot spread while reading both pulse quadratures. Determine whether a change of population comes from a shifted carrier or a fading phase.

Derive the spectral distinction between a phase-coherent pulse and stationary noise

A fluctuating perturbation is often characterised by a power spectral density rather than a prescribed pulse phase. Suppose \(V_{fi}(t)=d_{fi}F(t)\) with \(F\) a real classical, zero-mean stationary random process and the coupling weak enough for first-order amplitudes in each realisation. Averaging the modulus squared produces a double time integral involving the autocorrelation \(C_F(\tau)=\langle F(t+\tau)F(t)\rangle\):

\[\langle P_f(T)\rangle=\frac{|d_{fi}|^2}{\hbar^2}\int_{-T}^{T}(T-|\tau|)C_F(\tau)e^{i\omega_{fi}\tau}\,d\tau.\]

The factor \(T-|\tau|\) counts the length of pairs of times in \([0,T]\) separated by \(\tau\). If \(T\) is long compared with the correlation time and depletion remains weak, divide by \(T\) to find rate \(|d_{fi}|^2S_F(\omega_{fi})/\hbar^2\), where \(S_F(\omega)=\int_{-\infty}^\infty C_F(\tau)e^{i\omega\tau}d\tau\) is the two-sided angular-frequency spectrum. No sum over a continuum of final quantum states was involved here. A continuum of drive frequencies supplies a different physical route to an approximately linear transition probability of one resolved final state.

For exponentially correlated noise \(C_F(\tau)=F_{\rm rms}^2e^{-|\tau|/\tau_c}\), integration gives

\[S_F(\omega)=2F_{\rm rms}^2\tau_c/[1+\omega^2\tau_c^2].\]

Fix \(F_{\rm rms}\) and vary correlation time. At a nonzero fixed transition frequency, extremely rapid fluctuations have little integrated spectral weight there because their fixed variance is spread over a very broad band. Very slow fluctuations concentrate their weight near zero frequency. Differentiating the spectral expression gives a maximum excitation rate at \(\tau_c=1/|\omega_{fi}|\). This nonmonotonic dependence cannot be inferred just by quoting the field's total rms amplitude. Unit conventions are also critical: changing to ordinary-frequency spectral densities and a one-sided instrument display requires the corresponding Jacobian and factor of two.

A real classical stationary process has an even spectrum \(S_F(-\omega)=S_F(\omega)\), so this model drives upward and downward transitions equally per available source population when matrix elements are conjugate. A quantum environment at thermal equilibrium can have unequal positive and negative frequency unsymmetrised spectra. Its absorption and emission probabilities encode detailed balance. Thus an observed difference between calibrated upward and downward rates cannot generally be explained by merely drawing samples from a real classical noise spectrum of the same symmetrised power. Distinguishing a driven classical source from an equilibrium quantum bath requires precise statements about which correlations enter the transition probability.

Infer a fluctuation timescale from a rate ratio

Two transitions with equal coupling strengths see the same exponentially correlated classical field at ordinary frequencies \(f\) and \(2f\). Their measured weak transition rates obey \(\Gamma(2f)/\Gamma(f)=0.40\). Infer the dimensionless correlation frequency and, for \(f=50.0\) kHz, the correlation time. What feature of the acquisition would invalidate this inference?

Derive and check the result

Let \(x=(2\pi f\tau_c)^2\). The ratio is \((1+x)/(1+4x)=0.40\), giving \(0.60=0.60x\) and \(x=1\). The correlation time is

\[1/(2\pi f)=3.18\,\mu\mathrm s.\]

At the lower frequency the noise spectrum lies at half its zero-frequency value; the higher line samples one fifth of that value. If the exposure time is comparable to or shorter than \(\tau_c\), the triangular window in the double integral still influences both rates and the infinite-time Lorentzian ratio is inadequate. Likewise unequal matrix elements or a finite observation band must be corrected separately. Measuring a third transition at another frequency supplies an independent test of the exponential-correlation model rather than simply determining its fitted timescale.

Tutorial · choose a pulse duration and check the perturbation

Measure a frequency width without confusing two line shapes

A rectangular pulse lasts 4.00 ms with resonant coupling \(|v|/\hbar=25.0\,\mathrm{s^{-1}}\). Find the line-centre probability, separation of the first zeros and full half-height width in hertz.

Work through the solution

At resonance first-order probability is

\[(25\times0.004)^2=0.0100.\]

The first zeros are 250 Hz on either side, giving a 500 Hz separation. The full half-height width is

\[0.886/0.004=221.5\,\mathrm{Hz}.\]

A Lorentzian fit with its width interpreted as a spontaneous lifetime would mistake pulse broadening for decay. Doubling \(T\) while keeping coupling fixed is a diagnostic: the first-order peak would rise fourfold and the width halve. At large peak probability use the full two-level dynamics rather than extrapolating the quadratic indefinitely.

Verify the breakdown against exact two-level dynamics

Assume an isolated resonantly driven two-state system with rotating-frame Hamiltonian off-diagonal \(v\) and zero detuning. What replaces the first-order expression when \(T=\pi\hbar/(2|v|)\)? At which small pulse area is the fractional error approximately one percent?

Work through the solution

The resonant Hamiltonian squares to \(|v|^2I\), so the exact probability is \(\sin^2(|v|T/\hbar)\). At the stated pulse time it is unity while the first-order result is \((\pi/2)^2=2.47\), impossible as a probability. For pulse area \(a=|v|T/\hbar\),

\[\sin^2a=a^2-a^4/3+\cdots.\]

The relative discrepancy is approximately \(a^2/3\), reaching 1% at \(a\simeq0.173\). The pulse can already make a measurable few-percent transition while first-order theory remains reasonably accurate. A dense continuum requires checking the total across all levels as well.

Infer an accessible density from the observed time dependence

At long-enough but weak-depletion times an ensemble loses 2.0% population in 5.0 ns. The squared box matrix element is calibrated as \(2.5\times10^{-17}\,\mathrm{eV^2}\). Infer \(\rho\), estimate the recurrence scale and test whether this interpretation is internally consistent.

Work through the solution

The slope estimate is \(4.0\times10^6\ \mathrm{s^{-1}}\). With \(\hbar=6.5821\times10^{-16}\,\mathrm{eV\,s}\) the inferred \(\rho=\Gamma\hbar/(2\pi|v|^2)=1.68\times10^7\,\mathrm{eV^{-1}}\). The corresponding spacing is \(5.97\times10^{-8}\) eV and recurrence scale \(h/\delta E\simeq69\) ns. A 5 ns observation fits within that scale, with about 14 spacings to the first zero. Two percent is compatible with weak depletion. Smoothness of the density and a single accessible channel still require independent spectral checks. Repeating the measurement at several durations reveals whether the inferred slope is stable.

Further reading

Which part of a Bell correlation survives imperfect state preparation?

A source emits two spin-half systems in the singlet state. Two observers select measurement directions separately and record outcomes \(+1\) or \(-1\). Construct a Bell–CHSH statistic from four measurable correlations and determine how state preparation, angular alignment and finite sample size affect the prediction.

Relate a counted coincidence to an operator

Denote unit measurement directions by \(\mathbf a,\mathbf b\). Outcome projectors are \((1+s\,\boldsymbol\sigma\cdot\mathbf a)/2\) and \((1+t\,\boldsymbol\sigma\cdot\mathbf b)/2\), for \(s,t=\pm1\). The singlet has zero individual spin expectation and tensor \(\langle\sigma_i\otimes\sigma_j\rangle=-\delta_{ij}\). The diagonal entries follow because measurements along any common axis are exactly opposite and the state is rotationally invariant. Its joint probability is

\[p(s,t|\mathbf a,\mathbf b)=\tfrac14(1-st\,\mathbf a\cdot\mathbf b),\]
\[E(\mathbf a,\mathbf b)=-\mathbf a\cdot\mathbf b.\]

Summing over either outcome leaves one half for the other observer, independent of the remote angle. Covariance can change while the individual counting rates remain constant. At an angle of 60 degrees the probabilities of the two equal-outcome combinations sum to one quarter, and of opposite outcomes to three quarters. Their signed difference gives −0.5. The lab models spin-axis angles; linear polarisation analysers give a doubled angle in their effective two-state representation.

Derive a bound and choose a set of directions

If a trial had four predetermined local binary responses \(A,A',B,B'\), its combination \(AB+AB'+A'B-A'B'=A(B+B')+A'(B-B')\) would have magnitude two, since exactly one of the parentheses vanishes. Averaging over a common distribution of such assignments preserves the bound. The quantum prediction combines expectation values measured on different subensembles with independently chosen setting pairs. Use coplanar angles \(a=0,\ a'=\pi/2,\ b=\theta,\ b'=-\theta\).

\[S=E(a,b)+E(a,b')+E(a',b)-E(a',b')=-2(\cos\theta+\sin\theta).\]

At \(\theta=45^\circ\) its magnitude is \(2\sqrt2\). The derivative vanishes there, making small symmetric angular errors second order. If a fraction \(1-v\) of pairs is completely unpolarised, the density operator is \(v|\Psi^-\rangle\langle\Psi^-|+(1-v)I/4\). Every correlator gains a factor \(v\). The best attainable magnitude exceeds two only when \(v>1/\sqrt2\). This is a statement about this measurement family and this noise model. A pair source and a scalar contrast alone do not define an experimental protocol.

Assess one set of finite counts

At \(v=0.80\), \(\theta=45^\circ\) the expected magnitude is about 2.263. Each trial product is a binary variable with variance \(1-E^2\). For \(N\) independent pairs per setting, the sample correlation variance is \((1-E^2)/N\). Assuming independent subensembles, variance of the signed sum is the sum of the four variances. Here every squared correlation is 0.32. With 1000 trials per setting the approximate standard error of the statistic is

\[\sqrt{4(1-0.32)/1000}=0.0522.\]

The excess 0.263 is roughly five standard errors under this idealised independent-trial model. It is not a substitute for a finite-sample hypothesis test that accounts for an actual protocol's setting choices, losses, timing and possible memory.

Change settings and preparation independently

Inspect the predicted absolute statistic and the local assignment bound. Find the angles for which the chosen source can exceed two. Then vary visibility at a fixed angle. Small individual spin polarisation drifts could alter the marginal counts; unequal channel efficiencies could change a coincidence-selected sample. Monitoring all four joint count tables and both single-observer marginal distributions allows more checks than retaining only their final sum.

Tutorial

At visibility 0.70, can increasing the number of trials eventually make the expected maximum exceed two?

Work through the solution

No. The largest mean value is \(2\sqrt2(0.70)=1.980\). More trials narrow the sampling distribution around that value. Changing the preparation or measurement family addresses a different question.

What is the predicted fractional loss at an angle \(\delta\) away from the optimum, and how large is it at five degrees?

Work through the solution

Write \(\cos\theta+\sin\theta=\sqrt2\cos(\theta-\pi/4)\). The fractional loss is \(1-\cos\delta\), about \(0.00381\) at five degrees. Asymmetric offsets on different analyser axes need not enter the same way.

A paper gives one large value of \(|S|\) but discards all pairs for which one detector was silent. Can the ideal bound derived above automatically be applied to these retained counts?

Work through the solution

The derivation averaged all setting pairs over a common underlying ensemble. Setting- or state-dependent retention can alter those ensembles. One needs the trial definition, data handling and efficiency assumptions to interpret the reported statistic.

For state preparation and independent measurement on tensor factors, revisit the composite-state chapter.

Recover a transition frequency from two separated pulses

A two-level system is driven by two short pulses with a free evolution interval between them. Determine why a population measurement carries phase information. Use a scan at several delays to separate a constant detuning, intrinsic coherence loss and trial-to-trial frequency variation.

Follow the amplitudes through both pulses

Use basis \(|g\rangle,|e\rangle\). Let the first pulse prepare \((|g\rangle+|e\rangle)/\sqrt2\) in the frame of the applied oscillator. A detuning \(\Delta\) in radians per second accumulates a relative phase \(\Delta\tau\) in free time \(\tau\). Immediately before the second pulse each state has population one half; measuring population here cannot reveal detuning. Choose a second pulse equivalent to projecting onto \((|g\rangle+e^{-i\phi}|e\rangle)/\sqrt2\). Then one output population is

\[P(\tau,\phi)=\tfrac12[1+\cos(\Delta\tau-\phi)].\]

The sign of the phase follows our definitions of detuning and the reference pulse. Shifting the reference phase makes it possible to check that sign. A measurement using only \(\phi=0\) cannot distinguish \(\Delta\) from \(-\Delta\). Coherence is the off-diagonal density-matrix element that the second pulse converts into an observable population difference.

Derive two envelopes with different origins

A homogeneous decay time \(T_2\) multiplies the off-diagonal element by \(e^{-\tau/T_2}\). If instead the detuning of each experimental shot is constant during that shot and drawn from a Gaussian distribution of mean \(\bar\Delta\) and standard deviation \(\sigma_\Delta\), average the complex phase, not its absolute value. Completing the square in the Gaussian integral gives

\[\langle e^{i\Delta\tau}\rangle=e^{i\bar\Delta\tau}e^{-\sigma_\Delta^2\tau^2/2}.\]

With both independent mechanisms the measured contrast is \(C(\tau)=\exp[-\tau/T_2-\sigma_\Delta^2\tau^2/2]\). One mechanism gives an initial logarithmic slope, the other adds curvature. A single low contrast measured at just one delay cannot establish which one caused it.

Infer parameters from quadratures and a frequency scan

Record the \(\phi=0,\pi/2\) outputs, then form \(X=2P_0-1=C\cos(\bar\Delta\tau)\) and \(Y=2P_{\pi/2}-1=C\sin(\bar\Delta\tau)\). Their length estimates contrast and their angle estimates accumulated phase modulo \(2\pi\). Suppose at \(0.50\,\mathrm{ms}\) the readings are 0.500 and 0.850. Then \(X=0,\ Y=0.700\), and the phase is \(\pi/2\) modulo \(2\pi\). With an independent bound \(|\bar\Delta/2\pi|<1\,\mathrm{kHz}\), the implied cyclic detuning is \(+500\,\mathrm{Hz}\). Longer delays resolve fine frequency differences at the cost of phase ambiguity and declining contrast. Use a shorter-delay record to unwrap a longer one.

At a contrast of 0.700 the relation \(-\ln(0.700)=\tau/T_2+\sigma_\Delta^2\tau^2/2\) supplies one equation for two unknowns. Several delays, with independent error bars, are needed to identify the linear and quadratic terms. At very low signal the length \(\sqrt{X^2+Y^2}\) has a positive noise bias. Fitting the two directly measured quadratures can be preferable to fitting the length.

Explore two mechanisms

The graph holds the homogeneous \(T_2\) at 2 ms. It lets you set signed cyclic detuning and shot-to-shot cyclic frequency spread. Compare both quadrature populations with the upper contrast envelope. First reverse the sign of the detuning, then increase the spread without changing the mean. Which effect interchanges peaks of one quadrature and which damps both?

Tutorial

What is the fringe spacing in a scan of cyclic detuning at fixed delay of 0.80 ms?

Work through the solution

One full phase cycle needs \(\delta f\,\tau=1\). The spacing is

\[1/0.00080=1250\,\mathrm{Hz}.\]

The angular-frequency spacing is \(2\pi\) times larger.

A fixed delay gives

\[P_0=P_{\pi/2}=0.5.\]

Does that show a phase of 45 degrees?

Work through the solution

Both centred quadratures are zero, so the contrast is unresolved and the angle is undefined. A phase of 45 degrees with finite contrast gives equal, nonzero centred quadratures.

Explain how a refocusing pulse halfway through the evolution helps identify quasistatic detuning noise.

Work through the solution

The pulse exchanges the phase-accumulating states, reversing phase winding for a detuning that stays constant through both halves. Random variations during the interval need not cancel. Recovering contrast in the refocused sequence supports a slowly varying contribution to the original envelope.

Compare a continuous drive in the transition chapter with the role of the second pulse here.

Mechanical and thermal effects of light

Calculate how a beam can translate a bead, couple resonances or exchange energy with a moving boundary. Test each proposal against a measured signal.

  1. Optical trapping and Brownian calibration of a dielectric bead
  2. Coupled optical and mechanical resonances
  3. Thermal radiance, étendue and detector calibration
  4. Moving-mirror Doppler metrology
  5. Where momentum waits between source and receiver
  6. Why a small transparent sphere scatters light
  7. From wavefronts to rays, focusing and caustics

Optical trapping and Brownian calibration of a dielectric bead

An image of a bead remaining near a focus does not establish the strength of its trap. Derive the force pulling a small dielectric sphere into a bright region, compare it with the forward force from scattering and learn what a motion record can tell you about stiffness, drag and temperature. The model here uses an inert dielectric sphere in a homogeneous Newtonian liquid.

From two dielectric boundaries to the energy of an induced dipole

A sphere of radius \(a\) and relative permittivity \(\epsilon_b\) sits in a liquid of relative permittivity \(\epsilon_m\). Assuming the sphere is small compared with a wavelength in the liquid, solve its local electric problem in an almost uniform applied field \(E\). Rotational symmetry about the field admits an interior potential proportional to \(r\cos\theta\). The exterior consists of the imposed potential \(-Er\cos\theta\) and an induced dipolar term proportional to \(\cos\theta/r^2\). Equality of potential and of normal displacement at the surface gives the local-field and dipole factors

\[E_{\rm in}=\frac{3\epsilon_m}{\epsilon_b+2\epsilon_m}E,\]
\[p=\alpha E,\]
\[\alpha=4\pi\epsilon_0\epsilon_m a^3\frac{\epsilon_b-\epsilon_m}{\epsilon_b+2\epsilon_m}.\]

The field doing the polarising work is the external field in the host at the particle position before inserting it. To turn that work into a potential, build up the dipole from zero rather than assuming a permanent dipole moment. Quasistatic assembly gives

\[-\int_0^E\alpha E'\,dE'=-\alpha E^2/2.\]

For a harmonic peak field average the square over an optical period. In a nearly lossless liquid of refractive index \(n_m\), the peak field is related to travelling-wave intensity by \(I=n_m\epsilon_0c|E|^2/2\). The resulting conservative force is

\[U=-\frac{\operatorname{Re}\alpha}{4}|E|^2=-\frac{\operatorname{Re}\alpha}{2n_m\epsilon_0 c}I,\]
\[\mathbf F_{\rm grad}=-\nabla U .\]

The two factors of two have different origins: induced-dipole assembly and time averaging of a sinusoid. Using a permanent-dipole potential with a peak field would miss both. A bead of higher refractive index than the liquid has positive real polarizability and is attracted to increasing intensity. A lower-index inclusion reverses this local tendency. For large particles, strong absorption or rapidly structured fields, a dipole with real static polarizability no longer specifies the force; a field or multipole calculation of the complete momentum balance is required.

Investigate the small-sphere dipole response and its dependence on particle size

Compute a transverse stiffness and test how local it is

Assume the beam near its focal plane has intensity \(I(x)=I_0e^{-2x^2/w^2}\), with power \(P\), waist \(w\) defined at \(1/e^2\) intensity and \(I_0=2P/(\pi w^2)\). Put \(U_0=\operatorname{Re}\alpha I_0/(2n_m\epsilon_0c)>0\). The potential measured above its minimum is \(U_0[1-e^{-2x^2/w^2}]\). Expanding to second order and equating its leading term to \(\kappa_xx^2/2\) gives

\[\kappa_x=4U_0/w^2.\]

Stiffness therefore scales linearly with power, as the third power of sphere radius and as the inverse fourth power of waist at fixed indices. Each scaling applies within the stated approximations.

For a 40 nm radius bead with \(n_b=1.59\), take \(n_m=1.33\), \(w=0.65\) micrometres, vacuum wavelength 1064 nm, \(P=90\) mW and \(T=298\) K. The index contrast factor is 0.1252 and the waist intensity is \(1.36\times10^{11}\) watts per square metre. The predicted depth \(3.03\times10^{-20}\) J is 7.36 times the thermal energy. The lateral stiffness is \(2.87\times10^{-7}\) N/m. A displacement of 50 nm then requires approximately 14.3 fN of transverse balancing force. At a displacement of half a waist, the exact restoring force is the harmonic estimate multiplied by \(e^{-1/2}=0.607\); a Hookean calibration cannot be extrapolated that far.

Use the two curves to identify the interval in which the local quadratic energy is within ten percent of the Gaussian prediction. First lower power at fixed waist. Both curves shrink together in energy units while the harmonic thermal displacement grows. Next increase bead radius at fixed power and watch the well deepen, but also evaluate the size parameter \(2\pi n_ma/\lambda_0\). It is 0.314 at the default and grows linearly with radius. Stronger trapping predicted by this simplified model does not establish the accuracy of the dipole approximation at arbitrary sizes.

Compare axial restoring force with radiation pressure

An induced dipole reradiates a portion of the incident field. In a uniform host use the Rayleigh scattering cross section \(\sigma_s=(8\pi/3)k_m^4a^6|(\epsilon_b-\epsilon_m)/(\epsilon_b+2\epsilon_m)|^2\). In a common travelling-wave momentum-flux model for a bead in a stationary nondispersive liquid the axial scattering force is approximately \(F_s=n_m I\sigma_s/c\); absorption would add a further contribution. This estimate uses the total scattering cross section because the leading dipole pattern has vanishing mean forward cosine. For a larger forward-scattering sphere a transport cross section weights the deflected momentum instead.

In the default case the cross section is roughly \(2.05\times10^{-18}\) square metres. The forward force at the waist is about 1.23 fN. A Gaussian axial profile has \(I(0,z)=I_0/[1+(z/z_R)^2]\) with \(z_R=\pi n_mw^2/\lambda_0=1.66\) micrometres. Its local axial stiffness \(2U_0/z_R^2=2.20\times10^{-8}\) N/m is much smaller than its transverse stiffness. Balancing the constant forward force with that local stiffness predicts an equilibrium about 56 nm downstream of the waist. The small displacement relative to the Rayleigh length supports the linearisation.

Both the axial stiffness and forward scattering force scale with power in this simple model. A power sweep can thus increase confinement while barely shifting the equilibrium offset, a useful discriminating prediction. At fixed focus the offset grows rapidly with bead size because the scattering force scales with the sixth power and the gradient force with the third power. A stable lateral position alone does not establish stable three-dimensional capture. Check the axial restoring slope at a force zero and verify that thermal escape and fluid flow are negligible over the acquisition interval.

Extract stiffness from fluctuations or from a relaxation time

Near a stable point in one Cartesian direction, let \(x\) denote displacement from the mean and \(\zeta\) the viscous drag. At sufficiently low frequencies the inertial term is negligible and the overdamped Langevin equation is

\[\zeta\dot x=-\kappa x+\xi.\]

At equilibrium the fluctuating force has zero mean and white covariance \(2k_BT\zeta\delta(t-t')\) over the frequencies considered. The deterministic relaxation time is

\[\tau=\zeta/\kappa.\]

Multiplying the equation at positive delay by \(x(0)\) and averaging removes the uncorrelated later noise and gives the decaying covariance. Equipartition sets its initial value.

\[C(t)=\frac{k_BT}{\kappa}e^{-|t|/\tau},\]
\[f_c=\frac{\kappa}{2\pi\zeta},\]
\[S_x^{(1)}(f)=\frac{4k_BT\zeta}{\kappa^2+(2\pi f\zeta)^2},\quad f\ge0 .\]

The stated spectrum is one-sided in ordinary frequency. Its integral from zero to infinity equals \(C(0)\); doubling another time would double the variance. In an unbounded fluid with viscosity 1.00 mPa s, Stokes drag is \(6\pi\eta a=7.54\times10^{-10}\) N s/m. The default predicts \(f_c=60.5\) Hz and rms displacement 120 nm. The latter is roughly 0.18 waist, so the outer part of a long thermal trajectory may sample appreciable anharmonicity. A finite-depth well in an unbounded bath does not have a globally normalisable trapped equilibrium. These local equilibrium predictions apply to a sufficiently long-lived, locally sampled trapped state.

If a voltage detector gives \(V=gx\), the spectral corner and normalised autocorrelation time do not depend on the displacement gain \(g\). They determine only \(\kappa/\zeta\). Equipartition using a calibrated spatial variance gives \(\kappa\) independently of drag, provided mechanical fluctuations are in equilibrium and sufficiently resolved. If the viscosity or nearby-wall drag is uncertain, combining a known stage oscillation with the Brownian spectrum can determine further calibration quantities. Keep a stage-driven coherent peak out of the noise integral used for equipartition.

Account for exposure, sample size and unobserved motion

A camera typically reports the position averaged during an exposure of duration \(t_e\). Its variance is the double integral of the covariance over the exposure interval divided by \(t_e^2\). Evaluating the exponential local model and introducing \(u=t_e/\tau\) gives a multiplicative factor \(2(u-1+e^{-u})/u^2\). At \(u=1\) the reported physical-motion variance is only 0.736 of the instantaneous variance. Interpreting it as the full variance would overestimate stiffness by approximately 36 percent. Independent pixel-localisation noise adds additional variance with the opposite sign of bias.

Estimate that localisation noise with an effectively immobilised reference bead at a comparable brightness. Test the averaging correction by changing exposure duration at constant sampling frequency where possible. A camera that reports overlapping exposures has correlated measurement errors and needs a different covariance model. A long series of closely spaced frames also contains fewer independent thermal configurations than its frame count suggests. Compare estimates across several blocks substantially longer than the relaxation time; residual low-frequency drift can dominate even when high-frequency position precision looks excellent.

A separate check uses a known uniform liquid flow. At a steady small displacement \(x_s\), force balance gives

\[\kappa x_s=\zeta u_{\rm flow}.\]

For the default drag and stiffness a flow of 10 micrometres per second gives an offset of 26.3 nm. Repeat with reversed flow and use half the displacement difference to cancel an unknown zero-force position. Near a wall, the local flow at the bead and wall-corrected drag may differ from a stage velocity and the unbounded Stokes value. Those effects alter the mechanical calibration even if the optical field is unchanged.

A known stage oscillation calibrates position in a fluid

Brownian fluctuations alone determine the product of several unknown calibration parameters. A weak sinusoidal translation of the sample cell adds a known mechanical signal at a chosen frequency. Work in laboratory coordinates with a fixed optical trap and with fluid moving uniformly at velocity \(u(t)\) near the bead, well away from walls in the idealised model. The drag is now \(-\zeta(\dot x-u)\). Superposing a stage displacement \(A\cos\omega t\) on thermal fluctuations gives a deterministic response whose complex amplitude satisfies \((\kappa-i\omega\zeta)\widetilde x=-i\omega\zeta A\) in the negative-exponential convention. Therefore its amplitude ratio is

\[\frac{|\widetilde x|}{A}=\frac{\omega\tau}{\sqrt{1+\omega^2\tau^2}} .\]

At the trap corner the bead displacement amplitude is the known stage amplitude divided by the square root of two. A calibrated 80.0 nm stage oscillation there produces a predicted bead amplitude of 56.6 nm. If a position-sensitive receiver records a coherent peak amplitude of 0.170 V, its displacement gain is 3.01 mV/nm. At very low drive frequencies the fluid velocity is small for fixed stage amplitude and the trap holds the bead nearly stationary. At high enough frequency the bead follows the fluid displacement within the overdamped model, but finite hydrodynamic, optical and electronic bandwidths eventually matter.

After determining the gain, convert the surrounding voltage spectrum into spatial units and use the area of the stochastic fluctuation spectrum to find stiffness. Exclude the calibrated line and account for the finite spectral averaging window; a narrow drive that leaks into neighbouring bins can inflate the inferred thermal variance. Dividing measured stiffness by the independently determined corner rate then gives drag, which can be compared with the known viscosity and sphere radius. This avoids assuming free-space Stokes drag in the first step of a near-wall measurement.

There are two limiting systematic effects that a good fit to a single drive frequency cannot resolve. A frequency-dependent stage calibration changes the actual fluid displacement, and motion of the optics relative to the cell generates a direct detector background even with the bead immobilised. Repeat the drive above and below the corner, compare coherent phase as well as amplitude and acquire a trapped and immobilised reference. Correct conversion should explain the entire complex response with one spatial gain and one corner time. A single calibration number obtained at one frequency can hide a phase lag in the stage controller or in the optical position channel.

One last cross-check reverses the stage drive phase by half a period. The coherent bead response must reverse, while thermal background power remains unchanged. A component that fails this reversal could come from ambient vibration unrelated to the stage. Averaging the two traces with and without a sign change separates these contributions before either is used in an optical-force calibration.

Tutorial · Separate a unit-conversion error from excess noise

In a single-axis trap at 298 K a calibrated detector reports a variance of 2500 square nanometres after removal of localisation noise and exposure correction. An independent spectral fit gives a corner of 175 Hz. Infer stiffness, drag and the equivalent unbounded hydrodynamic radius for a liquid of viscosity 1.00 mPa s. Compare against a nominal 80 nm radius bead.

Infer the three quantities and test their consistency

A nanometre squared is \(10^{-18}\) square metres, so the variance is \(2.50\times10^{-15}\) square metres. Equipartition gives \(1.65\times10^{-6}\) N/m. Dividing by \(2\pi f_c\) gives drag \(1.50\times10^{-9}\) N s/m and radius \(\zeta/(6\pi\eta)=79.5\) nm. The agreement supports the local overdamped description under the assumed temperature and viscosity. Forgetting the factor of \(2\pi\) would predict a radius roughly six times larger and could be mistaken for a huge near-wall correction.

Now imagine that additional uncorrelated read noise had been left in the variance. This raises apparent variance, lowers the equipartition stiffness and would lower the inferred drag at the same fitted corner. Nearby-wall drag for a given radius instead normally raises hydrodynamic resistance for parallel translation. Their effects on the inferred radius thus differ in sign under the stated assumptions. Varying height and independently calibrating the measurement noise are appropriate diagnostics before attributing a discrepancy to bead dimensions.

Tutorial · Test a force-law inference with power and concentration controls

At fixed bead radius a trap is operated at two powers differing by a factor of two. Measured corner frequencies increase from 42 to 84 Hz, but rms displacement falls only from 110 to 87 nm. What does the harmonic model with fixed drag and temperature predict? Estimate a power-independent additive position-noise variance that could reconcile the two readings.

Use two variances to separate scale and offset

The doubled corner gives doubled stiffness if drag is unchanged. Physical thermal variance should halve. The predicted rms at higher power would be 77.8 nm if the lower-power value were entirely physical. Let the low-power measured variance be \(v+b\) and the high-power one \(v/2+b\), where \(b\) is a constant additive noise variance. Solving from 12,100 and 7,569 square nanometres gives \(v=9062\) and \(b=3038\) square nanometres, or approximately 55.1 nm rms noise.

This is a large inferred detector noise and demands an independent immobilised reference check. Power-dependent heating of the liquid changes temperature and viscosity, so an unchanged product inferred from only two quantities cannot prove that heating is absent. Test several powers, reverse their order to reveal slow drift and vary bead concentration to exclude overlapping particles in the tracking window. The inferred additive term should remain constant across those controls if it comes from the specified detector model.

Tolić-Nørrelykke and colleagues · position and force calibration using thermal and driven measurements

Coupled optical and mechanical resonances

A vibrating mirror can imprint its position on an optical field, while the stored light pushes back on the mirror. An apparent pair of peaks can indicate two hybrid modes, interference at a readout port or two unrelated resonances. Starting from energy in a moving cavity, derive the coupled response and learn which measurements establish a coupling strength and its uncertainty.

From a moving boundary to a force per photon

Take a nearly empty Fabry–Pérot cavity of optical length \(L\) with one moving end. A longitudinal resonance has \(\omega_c=m\pi c/L\) for integer \(m\), neglecting frequency-dependent mirror phase. For a small extension \(x\), \(\delta\omega_c=(\partial\omega_c/\partial x)x\) with signed slope \(G_x=-\omega_c/L\). At fixed photon number \(n\) the optical energy is \(n\hbar\omega_c(x)\). Its derivative gives the radiation-pressure force on the coordinate. For this mirror \(F=-n\hbar G_x>0\) pushes outward. The derivative must be at fixed photon number. Differentiating a driven steady-state photon number as though it were a closed-system energy would incorrectly include work exchanged with the pump.

For a 10 mm cavity resonant near 1064 nm the frequency slope magnitude in ordinary frequency is about 28.2 MHz per nanometre. A static shift of 10 pm therefore changes the optical resonance by approximately 282 kHz. One photon exerts a mean force \(\hbar\omega_c/L\simeq1.87\times10^{-17}\) N. An equivalent classical derivation counts a momentum change twice per normal reflection for each relevant round trip. The two descriptions yield the same mean force. The mirror displacement is the properly normalised mode coordinate; in a flexural device the optically sampled position and the total physical mass are generally different from centre-of-mass displacement and mass.

Introduce a single mechanical eigenmode with effective mass \(m_{\rm eff}\), angular frequency \(\Omega_m\) and displacement scale \(x_{\rm zpf}=\sqrt{\hbar/(2m_{\rm eff}\Omega_m)}\). The single-photon coupling magnitude is \(g_0=|G_x|x_{\rm zpf}\). This normalisation is convenient even when the observed vibrations are entirely classical. For \(m_{\rm eff}=10\) ng and \(\Omega_m/(2\pi)=1.0\) MHz, \(x_{\rm zpf}=9.16\times10^{-16}\) m and \(g_0/(2\pi)=25.8\) Hz for the stated optical geometry. The small displacement scale explains why a coherent pump is normally used to make the interaction measurable.

How a laser couples frequencies that are otherwise far apart

An optical carrier oscillates at hundreds of terahertz, whereas the mirror may vibrate at only megahertz. Direct comparison of these two bare frequencies would never suggest a resonant exchange. A strong coherent pump supplies a phase reference and converts a mechanical displacement into optical sidebands. Move into a frame rotating at the pump frequency and write the cavity amplitude as its large steady part plus a small perturbation. The leading frequency-shift interaction is proportional to photon number times displacement. Expanding the intensity around the large pump keeps terms linear in both the probe field and displacement. The resulting coupling is \(G=g_0\sqrt{n_c}\), where \(n_c\) is mean intracavity pump photon number.

Tune the pump about one mechanical frequency below the optical cavity resonance. In the resolved-sideband and weak-fluctuation limit a near-resonant process moves one excitation between the mechanical mode and an upper optical sideband. The rapidly rotating opposite-sideband terms average out. Now the two coupled frequencies are an optical sideband offset and the mechanical frequency, measured relative to a common rotating reference. The large carrier frequency has already been accounted for by the pump. The pump phase can be absorbed into the mode definitions, so \(G\) may be chosen positive for this isolated pair.

If instead the pump is placed near the upper sideband, the surviving interaction creates or annihilates excitations in pairs. The passive exchange equations below cease to apply and strong pumping can produce amplification or instability. A bare two-oscillator machine driven mechanically near a shared natural frequency often has analogous exchange equations without a carrier pump. Identical matrices can describe different energy supplies; identify the drive and rotating reference before assigning a literal photon-to-phonon energy conversion.

Derive complex poles and the effect of unequal damping

Let \(a,b\) be small energy-normalised optical and mechanical complex amplitudes. In a frame where the uncoupled optical sideband has zero frequency, let the mechanical detuning be \(\delta\). Let \(\kappa,\Gamma\) denote energy linewidths in angular frequency, so amplitude decay rates are half these values. With an optical probe \(s\) at offset \(\omega\), the linear system is

\[\begin{pmatrix}\kappa/2-i\omega&iG\\ iG&\Gamma/2-i(\omega-\delta)\end{pmatrix}\binom{a}{b}=\binom{s}{0}.\]

Zeros of the determinant give autonomous complex mode frequencies. In the lossless case the eigenvalues are \(\delta/2\pm\sqrt{G^2+(\delta/2)^2}\). Far off resonance each branch approaches a bare mode. At zero detuning the two eigenvectors have equal optical and mechanical weights and the splitting is \(2G\). The eigenvectors rotate continuously through the avoided crossing, an important discriminator from two uncoupled lines simply passing through one another.

At zero detuning with losses, completing the square in the determinant gives

\[\omega_\pm=-i(\kappa+\Gamma)/4\ \pm\sqrt{G^2-(\kappa-\Gamma)^2/16}.\]

The real parts separate once \(G>|\kappa-\Gamma|/4\). The shared imaginary part above that threshold corresponds to a hybrid energy linewidth \((\kappa+\Gamma)/2\). Resolving two intensity features on a given instrument is a stronger, readout-dependent condition. The dimensionless cooperativity \(C=4G^2/(\kappa\Gamma)\) is yet another measure, comparing interaction against the product of dissipation scales. A value greater than one does not automatically prove two resolved normal-mode poles in a device with very unequal linewidths.

Use frequency numbers divided by \(2\pi\) consistently from here for examples. With optical linewidth 240 kHz, mechanical linewidth 40 kHz and coupling 160 kHz, the real pole separation is

\[2\sqrt{160^2-50^2}=304\,\mathrm{kHz}.\]

Both hybrid energy linewidths are 140 kHz, and cooperativity is 10.7. If coupling falls to 45 kHz, cooperativity is still about 0.844 and no real zero-detuning pole separation appears. At 50 kHz the square root reaches zero. Near that threshold even a small linewidth or detuning calibration error has a large effect on a coupling estimate inferred from a single splitting.

Compute what an optical or mechanical receiver actually sees

Invert the matrix. With \(D=(\kappa/2-i\omega)[\Gamma/2-i(\omega-\delta)]+G^2\), the small amplitudes are \(a=s[\Gamma/2-i(\omega-\delta)]/D\) and \(b=-iGs/D\). The poles are shared. Their numerators are different, so the two channels can show different apparent maxima. A port in reflection also has a directly reflected field that interferes with the leaking intracavity amplitude. Its intensity can display a narrow dip or asymmetric feature without a matching resonance-height pattern inside the cavity. A legitimate forward model must describe the measured port.

The graph plots the internal squared amplitudes relative to the bare on-resonance optical probe energy. Set the mechanical detuning to zero and reduce the coupling through 50 kHz. Compare the optical dip with the predicted real pole separation. Then set a substantial positive detuning and follow the transfer of mechanical response onto one branch. As a control set the coupling exactly to zero. The optical curve recovers the bare cavity Lorentzian and the mechanical probe-induced response vanishes. A thermally excited mechanical background, absent from this driven calculation, could remain in a real detector.

At zero detuning and zero probe offset,

\[a/a_{\rm bare}=1/(1+C).\]

For the default parameters the internal optical probe intensity at the centre is only \(1/(1+10.67)^2=0.00735\) of the bare peak. This deep feature alone still does not establish the pole spacing. An incoherent background, a frequency-dependent detector transfer or coherent feedthrough can alter peak and dip positions. Fit complex quadratures across a detuning series when available, and verify bare linewidths by independent ringdown or far-detuned spectra.

Check how energy linewidth and amplitude ringdown are related for one isolated resonance

Watch energy exchange in time and identify the linewidth convention

In an ideal equal-linewidth system starting with optical perturbation \(a(0)=a_0\), \(b(0)=0\) at zero detuning, change to symmetric and antisymmetric modes. Recombination gives

\[a(t)=a_0e^{-\kappa t/2}\cos Gt,\]
\[b(t)=-ia_0e^{-\kappa t/2}\sin Gt.\]

Their normalised total energy decays as \(e^{-\kappa t}\), while energy moves back and forth between optical sideband and vibration. The first full transfer occurs at \(t=\pi/(2G)\) if the rotating-wave approximation holds. For \(G/(2\pi)=100\) kHz, this is 2.50 microseconds. With a shared energy linewidth of 20 kHz in ordinary frequency the surviving energy fraction then is

\[e^{-2\pi(20\,{\rm kHz})(2.50\,\mu{\rm s})}=0.730.\]

A gated excitation shorter than the exchange period but long enough to avoid unwanted modes can prepare an approximately optical initial perturbation. Independent detection of an optical revival and a delayed mechanical response tests coherent exchange more strongly than the presence of two peaks alone. Comparing times of maxima directly with one half the reciprocal measured optical linewidth misidentifies the exchange physics. Check the decay of the sum of appropriately calibrated energies and the relative phase of the exchange. Electrical or optical feedthrough can produce a prompt apparent response with no mechanical build-up.

Infer a coupling with propagated measurement errors

When the two hybrid pole frequencies have been obtained from a justified fit and zero bare detuning is established, the coupling follows from the measured real separation \(S\):

\[G=\sqrt{S^2/4+(\kappa-\Gamma)^2/16}.\]

All quantities here can be expressed in the same ordinary-frequency units. If \(S=300\pm8\) kHz, \(\kappa=240\pm10\) kHz and \(\Gamma=40\pm4\) kHz, the estimate is 158.1 kHz. Independent small errors give

\[\partial G/\partial S=S/(4G)=0.474,\]
\[\partial G/\partial\kappa=-\partial G/\partial\Gamma=(\kappa-\Gamma)/(16G)=0.0791.\]

Combining in quadrature gives about 3.9 kHz uncertainty. A common frequency calibration can correlate all three inputs, and a fitted detuning and splitting from one scan may also be correlated. Use their covariance rather than multiplying independent error bars blindly.

A second inference varies intracavity pump power. Since \(G^2=g_0^2 n_c\), plot the squared fitted coupling against independently calibrated \(n_c\). A nonzero intercept could indicate an additional direct coupling, baseline fitting bias or a mode incorrectly assigned at low power. The linewidths themselves can vary with pump power because of heating or backaction, so fit or measure them across the scan. Incident optical power is not identical to stored photon number; cavity coupling, detuning and loss determine their relation.

A measured frequency shift and linewidth change reveal optical feedback

The same instrument can be operated below the resolved splitting regime and read out a dispersive shift of the mechanical response. Algebraically eliminate the optical amplitude in the two-mode equations while driving the mechanical mode weakly. Its inverse susceptibility acquires a self-energy contribution proportional to the optical susceptibility. Let \(x\) be probe frequency measured from the bare optical sideband and use the same linewidth convention as above. In the mechanical denominator the additional term is

\[\Sigma(x)=\frac{G^2}{\kappa/2-ix}=\frac{G^2(\kappa/2+ix)}{(\kappa/2)^2+x^2}.\]

Its real part adds to the amplitude damping, while its imaginary part shifts the resonant condition. At very weak coupling one can evaluate it at the bare mechanical frequency \(x=\delta\), because variation across the narrow mechanical peak is small. Near an avoided crossing or when the mechanical peak samples a large change in optical susceptibility, solve the coupled poles directly; simply adding a linewidth and shift then neglects the very hybridisation being tested.

In ordinary-frequency units choose \(G=10\) kHz, optical linewidth 200 kHz, mechanical linewidth 2 kHz and detuning \(+100\) kHz. At that offset the optical amplitude half-width is 100 kHz, giving \(\operatorname{Re}\Sigma=0.50\) kHz and \(\operatorname{Im}\Sigma=0.50\) kHz. The full mechanical linewidth increases from 2.0 to approximately 3.0 kHz. Its centre moves upwards by about 0.50 kHz with the adopted matrix signs. Moving to minus 100 kHz reverses the shift and preserves the added damping in this symmetric model. At zero detuning the predicted shift vanishes but the added linewidth is largest.

A scan on both sides is more discriminating than measuring broadening alone. A background rise in mechanical temperature changes integrated thermal noise and may change intrinsic loss, but need not reproduce this odd shift and even broadening pattern. Measure intrinsic linewidth far from the optical response and subtract that baseline. An unknown constant frequency offset can be removed with the two symmetric detunings, but an optical power dependence of cavity frequency can move the actual symmetry centre. Monitor the optical resonance during the scan.

The effective susceptibility describes classical feedback through the delayed optical field. It does not by itself specify the final mechanical temperature. A bath occupation or noise spectrum is also required to convert a damping change into an energy distribution. A driven response peak that broadens and lowers in amplitude is evidence for a changed susceptibility; thermal cooling additionally requires a calibrated measurement of the fluctuating mechanical displacement and its optical transduction.

Tutorial · A high cooperativity without resolved modes

A device has ordinary optical linewidth 1.00 MHz, mechanical linewidth 1.0 kHz and pump-enhanced coupling 30 kHz. Calculate cooperativity, compare the coupling with the real-splitting threshold and estimate the relative intracavity probe intensity at the central frequency. What observation would distinguish a narrow interference window from two separated poles?

Evaluate the three criteria independently

In kHz units the cooperativity is

\[4(30)^2/(1000\cdot1)=3.6.\]

The real-splitting threshold is \(999/4=249.75\) kHz, far above the actual coupling. Yet the zero-detuning centre intensity is \(1/(1+3.6)^2=0.0473\) relative to the bare optical peak. A narrow, deep structured feature is possible with no separated real pole frequencies in this model. The linewidth contrast permits mechanical response to interfere strongly within a broad optical susceptibility.

Acquire both amplitude and phase while scanning the absolute mechanical detuning and compare a coupled complex-response model with independently measured bare parameters. A pair of well-resolved poles should trace two consistent trajectories in both observables and can generate underdamped exchange in the time domain. A single optical intensity scan containing two flanks around a dip is insufficient to make that inference.

Tutorial · Diagnose an erroneous estimate of the single-photon coupling

An independent linewidth analysis gives pump-enhanced couplings 80 and 160 kHz at photon numbers \(4.0\times10^6\) and \(1.6\times10^7\). Estimate \(g_0/(2\pi)\) and predict the coupling at \(9.0\times10^6\) photons. A calibration revision doubles all inferred photon numbers while leaving the measured spectra unchanged. Which conclusions move?

Use coherent amplitude scaling and separate calibration from spectroscopy

Divide the respective couplings in ordinary frequency by the square roots of their photon numbers. Both give 40 Hz and the intermediate prediction is 120 kHz. Doubling all inferred photon numbers lowers the inferred single-photon coupling by \(1/\sqrt2\), to 28.3 Hz. The observed enhanced couplings, pole locations and cooperativities computed from measured linewidths stay the same. A prediction labelled by fixed physical photon number changes; a prediction at a repeatable laser setting can still be calibrated empirically.

To test the absolute calibration, compare the inferred single-photon value with the independent cavity frequency slope times the mechanical zero-point displacement. This requires an effective mass appropriate to the measured displacement and the actual cavity optical overlap. An incorrect choice of mechanical mode normalisation can mimic an error in stored photon number. Agreement across a power ratio tests the square-root scaling but cannot by itself determine the absolute optical or mechanical calibration.

Aspelmeyer, Kippenberg and Marquardt · cavity optomechanics, linearisation and strong coupling

Thermal radiance, étendue and detector calibration

A square millimetre of a heated object emits thermal radiation into an entire hemisphere. A detector sees only the rays accepted by its optics and only wavelengths to which it responds. Derive the equilibrium spectrum, follow it through an optical collection system and infer what temperature or emissivity a calibrated reading can actually determine.

Count optical states in a large equilibrium cavity

Take a cubic airless cavity of volume \(V\) in thermal equilibrium at temperature \(T\). For its bulk mode density we can use periodic boundary conditions. Allowed wavevectors are separated by \(2\pi/L\) in each coordinate. Count a spherical shell in wavevector space, divide by the volume per state and include two independent transverse polarisations. Substituting \(k=2\pi\nu/c\) gives

\[g(\nu)d\nu/V=8\pi\nu^2d\nu/c^3.\]

Using standing waves in an ideally reflecting large box gives the same leading volume density when directions and polarisations are counted consistently.

One oscillator mode of frequency \(\nu\) can hold \(m=0,1,2,\ldots\) photons. Its thermal occupation has probabilities proportional to \(e^{-mh\nu/k_BT}\). Summing the geometric series and taking its logarithmic derivative gives

\[\langle m\rangle=1/(e^{h\nu/k_BT}-1).\]

Multiplying by the density of modes and energy per photon gives spectral energy density \(u_\nu\). The zero-point contribution of a harmonic oscillator is not part of the thermal power exchanged between these black surfaces. At low frequency the result approaches an energy \(k_BT\) per mode; extending that classical limit to arbitrarily high frequency would make the integrated power diverge.

An isotropic distribution of energy travelling at speed \(c\) produces a normal flux through a small aperture weighted by the direction cosine. Per unit solid angle its radiance is \(B_\nu=cu_\nu/(4\pi)\). Transform to equal wavelength intervals using \(B_\lambda d\lambda=B_\nu|d\nu|\). The two useful spectral forms are

\[B_\nu=\frac{2h\nu^3}{c^2}\frac1{e^{h\nu/k_BT}-1},\]
\[B_\lambda=\frac{2hc^2}{\lambda^5}\frac1{e^{hc/(\lambda k_BT)}-1}.\]

The wavelength expression has units of watts per square metre per steradian per metre of wavelength. To express it per micrometre multiply by one millionth. At 400 K and 10 micrometres the result is 33.56 W per square metre per steradian per micrometre. At 295 K it is 9.14 in the same units. Equal wavelength and equal frequency bins carry different widths, so their distributions reach their maxima at different converted wavelengths. A spectrum's peak should always name its horizontal variable and spectral-density convention.

Distinguish emitter power from brightness in a chosen direction

For a black surface with angle-independent radiance into its outward hemisphere, integrate \(\cos\theta\,d\Omega\). The result is \(\pi\), not \(2\pi\). The emitted spectral power per unit area is \(\pi B_\lambda\). Integrate over frequency using \(x=h\nu/(k_BT)\). The remaining integral \(\int_0^\infty x^3/(e^x-1)\,dx=\pi^4/15\) follows by expanding \(1/(e^x-1)\) as a sum of exponentials and integrating term by term. This yields Stefan–Boltzmann exitance \(M=\sigma T^4\) and identifies the constant \(\sigma=2\pi^5k_B^4/(15h^3c^2)\).

A black patch of 1.0 square millimetre at 400 K emits about 1.45 mW into its entire outward hemisphere over all wavelengths. The same patch at 295 K emits about 0.429 mW. Replacing one by the other changes all-wavelength hemispherical power by about 1.02 mW. This is not the power a small infrared receiver sees through a narrow filter. The integrated emitter number is valuable for energy conservation, but by itself contains no receiver area, direction, passband or optical transmission.

The surface spectrum of a body in thermal equilibrium has directional spectral emissivity equal to its absorptivity in the corresponding reciprocal optical modes under the usual reciprocal-material conditions. An opaque diffuse grey surface with emissivity \(\epsilon\) in an isotropically illuminated background can be modelled by \(\epsilon B_\lambda(T)+(1-\epsilon)B_\lambda(T_{\rm bg})\). It emits less than a black surface but also reflects background. A shiny object viewed in a warm room may consequently display a radiance temperature nearer the reflected scene than its own physical temperature. Specular surfaces require explicit directional knowledge of that scene.

Derive the geometric acceptance without counting the angle twice

An area element \(dA\) normal to the collection axis emits into \(d\Omega\) at angle \(\theta\) a spectral power \(B_\lambda\cos\theta\,dA\,d\Omega\). For a uniformly filled cone of half-angle \(\alpha\) and a uniform patch of area \(A\), integrating gives \(A\pi\sin^2\alpha\). This is its geometrical throughput in air when there is no vignetting. Optical étendue more generally uses \(n^2dA\cos\theta\,d\Omega\). A lossless passive optical relay in geometrical optics preserves this phase-space measure; correspondingly \(L/n^2\) is conserved along a ray in transparent media under the usual stationary conditions.

A direct lens example makes the restriction tangible. An image relay enlarging a uniformly bright patch by a factor of two in each transverse direction forms an image four times the area. In a lossless paraxial design filling the original pupil, each image point then occupies one quarter the solid angle. A detector covering the whole enlarged image and accepting that cone can receive the original power. Placing a fixed small sensor at the image plane intercepts less area instead. Higher magnification has not created additional radiance, even if it makes a small detail easier to resolve.

For the same 1.0 square millimetre patch seen within ten degrees, the projected acceptance is \(9.47\times10^{-8}\) square metre steradian. A wavelength-independent combined transmission and detector absorption of 0.65 leaves effective acceptance \(6.16\times10^{-8}\) square metre steradian. Integrating the Planck curve from 8 to 12 micrometres gives source and background band radiances 133.74 and 35.43 W per square metre per steradian. Their difference yields only 6.05 microwatts in the receiver. Keeping a single midpoint radiance times four micrometres happens to be fairly close here, but there is no fixed universal midpoint correction across temperatures or filters.

Set source and ambient temperatures equal. The emitted and ambient curves remain finite while the differenced instrument reading vanishes. Increase the cone half-angle from ten to twenty degrees and predict the scale factor \(\sin^2 20^\circ/\sin^2 10^\circ=3.88\). The spectral shape should stay fixed if transmission is separable from angle. If real data shift spectral shape with aperture, inspect filter angle dependence, source nonuniformity and stray light. The integral in the readout is computed on the specified 8–12 micrometre band even though the graph shows wavelengths beyond it.

Convert received power to calibrated voltage or counts

A thermal detector may respond to absorbed power through a temperature rise and an electrical responsivity. A photon-counting detector measures absorbed photons, so its count rate contains a factor \(\lambda/(hc)\) multiplying spectral power before integration. Two receivers with identical geometric acceptance and nominal quantum efficiency can respond differently to a changing source temperature if one output is proportional to energy and the other to photon number. Calibrate the actual electrical transfer and make the time interval explicit for accumulated counts.

For an ideal linear power detector let \(V=V_0+gP\), with offset \(V_0\) and gain \(g\). Two calibrated sources spanning the use range determine both. A black reference port at the same ambient temperature can also reject a common background in a chopped measurement. A filter, window or warm lens that absorbs thermal radiation also emits it. If these optics remain unchanged and stable, part of their own emission cancels in a reference difference. A reference traversing a different path generally leaves a residual input that is not captured by an electronic dark measurement.

Suppose effective source-minus-ambient powers of 2.00 and 8.00 microwatts yield 0.120 and 0.420 V. The fitted slope is 0.0500 V per microwatt with an offset of 0.020 V. A reading of 0.320 V implies 6.00 microwatts after offset correction. Substituting the same reading directly into a single-point gain with zero assumed offset would bias the inferred temperature. Rechecking a third reference near six microwatts tests linearity, while repeated zero-input readings at realistic instrument temperature test offset drift.

Invert the radiance and propagate uncertainties

A narrowband blackbody radiance measurement can be inverted analytically by solving Planck's expression for \(T\). In a broad passband use numerical quadrature across the calibrated spectral response and solve a scalar monotone equation when emissivity and background are known. The derivative at a single wavelength is particularly informative for estimating precision. With \(x=hc/(\lambda k_BT)\),

\[\frac{\partial\log B_\lambda}{\partial\log T}=\frac{x}{1-e^{-x}},\]
\[T=\frac{hc/(\lambda k_B)}{\log[1+2hc^2/(\lambda^5B_\lambda)]}.\]

At 10 micrometres and 400 K the logarithmic sensitivity is 3.70. A one-percent relative radiance uncertainty therefore gives about 1.08 K temperature uncertainty if all other quantities are exact. An unknown five-percent emissivity error can dominate that estimate. A two-colour temperature ratio may reduce uncertainty from an emissivity that is constant across the two narrow bands, but cannot cancel an arbitrary spectral emissivity or a large reflected ambient component.

As an example consider a grey object at 400 K and ambient 295 K with emissivity 0.70. At ten micrometres its outgoing radiance is \(0.70(33.56)+0.30(9.14)=26.24\) in the earlier spectral units. Inverting as a perfect blackbody gives a brightness temperature of about 375 K. The difference is a physical radiance–temperature degeneracy. Repeat at known ambient temperatures while keeping the object thermally stabilised to constrain the reflected fraction. If heating the background changes the actual object temperature, a second independent temperature sensor or a transient thermal model is necessary.

When detector heat capacity sets the measured signal

Consider a thermal receiver of heat capacity \(C_d\) coupled to its surroundings with thermal conductance \(G_d\). For small excursions its temperature obeys \(C_d\dot\theta+G_d\theta=P_{\rm abs}(t)\), where \(\theta\) is the excess above its operating point. A voltage thermometer with responsivity \(r_T\) converts this into output. Its frequency-dependent power responsivity is \(r_T/(G_d-i\omega C_d)\). The geometric and spectral calculations determine absorbed optical power, while this thermal equation determines how much of its modulation appears at the electrical output.

Take \(C_d=2.0\) microjoules per kelvin and \(G_d=0.10\) milliwatt per kelvin. The thermal time constant is 20 ms and ordinary corner frequency is 7.96 Hz. A sinusoidal absorbed-power amplitude of 6.0 microwatts would give a static temperature rise of 0.060 K. At 20 Hz the amplitude is reduced by \(1/\sqrt{1+(2\pi f\tau)^2}=0.370\), leaving about 22.2 mK with a phase lag magnitude near 68 degrees. A receiver calibrated with a steady optical power is not automatically calibrated for this chopped experiment.

A square-wave chopper also changes the relation between time-domain peak differences and a lock-in's fundamental reading. For equal hot and reference dwell times, a square wave switching between powers \(P_1,P_0\) has fundamental sinusoidal peak amplitude \(2(P_1-P_0)/\pi\), with different factors for rms and peak reports. The thermal transfer attenuates this component at the chopper frequency and the odd harmonics at their respective frequencies. Substituting the full hot-minus-reference power directly into the first-harmonic response would overestimate the expected signal.

Measure a frequency sweep on a stable reference and test whether amplitude and phase share a single time constant. A geometrical error rescales the amplitude but ordinarily leaves this thermal phase unchanged. A second thermal mass or an electronic filter can introduce another pole. Lowering chop frequency increases thermal signal until the static limit but can expose low-frequency environmental drift. Choose the frequency by comparing the calibrated response with the measured noise spectrum.

Finally, a reference and an unknown source must illuminate the same active area if responsivity varies across the receiver. Imaging one source as a small spot and the other as a filled patch can create a calibration bias even when total spectral powers agree. Translating a reference spot across the detector or imaging the same aperture successively at both temperatures tests that spatial uniformity assumption.

If the sensor is used on a source much smaller than the calibrated reference aperture, record an image or a field-stop scan to determine its filling fraction. Otherwise even exact knowledge of filter transmission and thermodynamic temperature leaves an unknown geometrical scale factor. Aperture filling is part of the measurement equation, not an electronic gain setting.

Tutorial · Infer emissivity using two controlled backgrounds

An opaque diffuse sample at fixed temperature is observed at 10 micrometres against two isotropic backgrounds with calibrated spectral radiances 8.00 and 16.00 W per square metre per steradian per micrometre. The resulting outgoing readings are 25.00 and 27.00 in the same units. Infer emissivity and the sample's blackbody-equivalent radiance. Estimate the significance of independent reading errors of 0.10 units.

Separate the reflected and emitted contributions

The increased outgoing radiance is 2.00 for an 8.00 increase of background. Thus reflectivity is 0.250 and emissivity 0.750. The first measurement gives intrinsic blackbody radiance \([25.00-0.25(8.00)]/0.75=30.67\). The second returns the same value. With 0.10 independent uncertainty on each outgoing reading and exact backgrounds, the slope uncertainty is \(\sqrt2(0.10)/8=0.0177\), as is the absolute emissivity uncertainty. Larger background separation can improve this slope estimate if sample temperature stays fixed.

If the sample transmits radiation, the residual fraction does not all correspond to reflection. A controlled change behind the sample helps detect that additional path. A directional specular reflector exposed to a warm enclosure also does not necessarily see the same angular average used in the diffuse model. Without these checks, a formally precise fitted emissivity can describe the experimental surroundings instead of the material.

Tutorial · Design a numerical spectral-integration check

An engineer tabulates spectral radiance per micrometre on a wavelength mesh. Another rewrites the detector model on an equally spaced frequency mesh, obtaining a signal that differs by several percent after independent mesh refinement. Explain what must transform, what stays dimensionless and how to compare a photon-counting channel with a power channel.

Transform the complete measurement integral

The differential power \(B_\lambda\,d\lambda\) must equal \(B_\nu\,|d\nu|\), with \(|d\lambda/d\nu|=c/\nu^2\). A dimensionless transmission curve becomes the same physical transmission at \(\lambda=c/\nu\); it acquires no additional Jacobian. The integration bounds reverse when increasing wavelength is replaced by increasing frequency. A response specified per unit wavelength, or a calibrated gain integrating a particular finite bin, must instead be interpreted from how it was defined.

Evaluate a unit-transmission test using a very narrow band, then the full 8–12 micrometre band whose radiance values are given above. Refine each grid independently, treating sharp filter edges consistently and converting per-micrometre densities before using metres. For a photon counter divide each spectral power contribution by photon energy before summation. Replacing that energy by a single central-wavelength value is an approximation that should be checked against the full band and source temperature. Close agreement between two different meshes using the same incorrect density is not a valid units check.

NIST radiance-temperature calibrations · spectral radiance, sources and uncertainty

Moving-mirror Doppler metrology

A moving mirror changes optical phase, shifts the reflected frequency and exchanges energy and momentum with the light. In many displacement measurements the classical phase rule is extraordinarily accurate. Derive its exact inertial-frame counterpart, identify which time a detector samples and find the practical uncertainties that usually matter well before a relativistic correction does.

Match phases on a boundary that moves

In a vacuum laboratory let an incident plane wave travel along \(+x\) with phase \(kx-\omega t\). A perfectly reflecting plane mirror has position \(X(t)\), receding for positive velocity. The reflected wave travels along \(-x\) with phase \(-k_r x-\omega_r t+\phi_0\). At the moving conducting surface the tangential electric fields must cancel in the mirror rest frame. For a constant mirror speed this requires equality of the two phase rates evaluated on its trajectory. The phase reversal at reflection supplies a constant offset and disappears on differentiation.

\[kv-\omega=-k_rv-\omega_r,\]
\[\frac{\omega_r}{\omega}=\frac{1-\beta}{1+\beta},\]
\[\beta=v/c .\]

Here \(k=\omega/c\) and \(k_r=\omega_r/c\) are positive magnitudes. A receding mirror redshifts the reflected light and an approaching mirror blueshifts it. Another derivation boosts into the mirror frame, where incident and reflected frequencies are equal, reverses the wavevector and boosts back. This yields a product of two Doppler factors, one for each transformation. Multiplying the first factor by its inverse without reversing the wavevector would predict no shift.

Define the signed beat \(f_b=f_i-f_r\). The exact and first-order relations with vacuum wavelength \(\lambda_0\) are

\[f_b=\frac{2v}{\lambda_0(1+\beta)},\]
\[f_b\simeq\frac{2v}{\lambda_0},\]
\[v=\frac{\lambda_0 f_b}{2-\lambda_0 f_b/c}.\]

At 633 nm and \(v=2.00\) mm/s the beat is 6319.12 Hz. The relative correction to the first-order expression is only \(6.67\times10^{-12}\). Frequency scale, geometry and air refractive index are ordinarily much larger uncertainties in an uncorrected bench experiment. The same exact expression makes a genuinely different prediction at \(\beta=0.10\): \(f_r/f_i=0.81818\), whereas the first-order frequency ratio is 0.80. This latter value is a theoretical benchmark for the formula rather than a required moving-bench experiment.

Connect reflection time with the detector's interference phase

Put an ideal stationary beamsplitter and detector at the origin, and let the source continuously illuminate the mirror along the measurement arm. A wave arriving back at laboratory time \(t\) was reflected at \(t_r\) satisfying \(t=t_r+X(t_r)/c\). It left the beamsplitter at \(t_0=t_r-X(t_r)/c\). Combining these gives

\[t-t_0=2X(t_r)/c.\]

With a stable source and a fixed reference arm, the accumulated return phase relative to the reference is proportional to \(2kX(t_r)\) up to a constant and an electronic quadrature sign.

\[\phi(t)=\frac{4\pi X(t_r)}{\lambda_0}+\phi_{\rm off},\]
\[\frac1{2\pi}\frac{d\phi}{dt}=\frac{2v(t_r)}{\lambda_0[1+v(t_r)/c]} .\]

The denominator comes from differentiating the arrival-time condition. It is not obtained from differentiating a geometrical arm length at detector time while keeping the reflection time fixed. For very slow motion and a modest arm one can replace the retarded trajectory by the present one to high accuracy. At higher bandwidth a fixed path delay can still matter even if the velocity correction is tiny. A one-metre mirror distance gives roughly 3.34 ns from reflection event to detection.

A sinusoidally driven mirror with amplitude 100 nm and ordinary mechanical frequency 1.0 kHz has phase amplitude \(4\pi A/\lambda_0=1.99\) rad at 633 nm. The peak speed is 0.628 mm/s and peak signed beat about 1.99 kHz. The instantaneous beat changes sign at each mechanical turning point. A frequency counter returning a single unsigned average misses that directional information. Demodulating the phase or fitting the sinusoidal motion to both quadratures can recover position, speed and reversal times.

Infer displacement or signed speed without losing complete fringes

If stationary reference and returned fields overlap in polarisation, spectrum and space, their combined intensity contains a cross term proportional to \(\cos\phi\). A single intensity channel cannot distinguish increasing from decreasing phase at an intensity extremum. Two calibrated quadrature outputs ideally read \(X_s=V\cos\phi\), \(Y_s=V\sin\phi\) after removal of offsets and gain normalisation. Recover wrapped phase with the two-argument arctangent. Unwrap successive phase differences only when the sampling interval and noise allow the branch to be identified.

The signed velocity control reverses the direction traced by the quadratures. Hold its absolute value fixed and change sign. The cosine channel alone remains almost identical at laboratory speeds; the sine channel reverses the progression from its initial value. Reduce the visibility and keep in mind that the graph shows noise-free curves. With fixed electronic amplitude noise a smaller circle makes angular uncertainty larger, even though the exact underlying phase still advances at the same rate.

One full phase turn represents a physical mirror displacement of half the vacuum wavelength at normal incidence. A 20-fringe movement at 633 nm is 6.33 micrometres. If both endpoints retain phase residuals, add their signed difference to the complete turn count before converting to distance. A missed fringe biases displacement by 316.5 nm regardless of how accurately sub-fringe phases are fitted. For the default speed and wavelength the magnitude of frequency is 6.32 kHz. To unwrap a plain uniformly sampled phase with less than half a turn between adjacent samples one needs a sampling frequency above 12.64 kHz, and usually a margin for noise and acceleration.

Quadrature imbalance distorts the ideal circle into an ellipse shifted away from the voltage origin. Taking an arctangent of raw voltages then introduces a periodic position error. Record a slow multi-fringe calibration, fit channel offsets, scales and nonorthogonality, and test the recovered phase on held-out data with reversed motion. Calibration using only a tiny arc of the ellipse makes offset and scale poorly identifiable even if the residuals on that arc are small.

Close the energy and momentum balance at the mirror

One incident photon has energy \(hf_i\) and momentum \(+hf_i/c\). On reflection it has energy \(hf_r\) and momentum \(-hf_r/c\). The mirror acquires momentum \(h(f_i+f_r)/c\) and energy \(h(f_i-f_r)\). Their ratio is exactly \(v\) when the prescribed constant-speed reflection formula applies. A recoil-free moving boundary can exchange mechanical work \(v\,\Delta p\) while a drive maintains its velocity. For a freely recoiling low-mass mirror illuminated by a small number of photons the fixed-velocity approximation must be replaced by energy and momentum conservation for the joint system.

For an incident beam with power \(P_i\) crossing a stationary plane in the lab, the number of photons encountering the receding surface per laboratory time is \(P_i(1-\beta)/(hf_i)\). Multiply by transferred momentum per encounter to get the force on that moving surface. The result simplifies to \(F=(2P_i/c)(1-\beta)/(1+\beta)\). At rest, a 10 mW perfectly reflecting beam gives 66.7 pN. For a 2.0 mm/s receding mirror at that power, the corresponding mechanical work rate is only \(1.33\times10^{-13}\) W to leading order.

A detector fixed upstream sees reflected-wave intensity reduced by the square of the reflected frequency ratio for an ideal steady plane wave. Its received power change compared with a fixed-plane incident flux is not in general equal to the instantaneous work on the mirror. The region of field between the fixed reference plane and the moving surface grows or shrinks and stores energy. Instead compare powers crossing the moving boundary with their proper encounter rates, or account for the change of field energy in a specified control volume. For a finite pulse the integrated photon count is unchanged under perfect reflection and the total energy loss per photon is the Doppler shift already derived.

Estimate realistic errors before pursuing small corrections

At normal incidence in vacuum the first-order speed estimate is \(\lambda_0 f_b/2\). For a beam at angle \(\theta\) to the translation direction, with an appropriately arranged reflection/return geometry interrogating mirror-normal motion, the usual small-speed sensitivity along the normal includes \(\cos\theta\). A tilt of two degrees gives a relative cosine factor 0.99939, a 610 parts-per-million reduction. A plane mirror tilted relative to a fixed coaxial receiver can additionally send the reflected beam outside the collection path, so specify how oblique reflected and reference fields are recombined. Blindly interpreting reduced fringe visibility as a velocity correction conflates these two effects.

In a homogeneous stationary transparent medium a quasistatic phase measurement measures optical path \(nL\). If \(n\) changes during a displacement measurement, the phase derivative includes both \(n\dot L\) and \(L\dot n\) when the simple uniform-medium approximation holds. A refractive-index change of one part in a million over a 0.5 m arm imitates about 0.50 micrometres of path-length change. A short differential arm, a refractive-index reference or a controlled environment can separate it from actual motion. The vacuum relativistic formula cannot simply absorb an arbitrary time-varying medium by replacing \(c\) everywhere with \(c/n\).

For a phase-difference velocity estimate over a record of duration \(T\), the displacement noise from two independent endpoint phase errors of standard deviation \(s_\phi\) is \(\lambda_0\sqrt2s_\phi/(4\pi)\). At 633 nm, \(s_\phi=0.010\) rad and \(T=2\) ms, the resulting velocity uncertainty is about \(0.356\) micrometres per second. Fitting a slope over many samples can improve white-noise precision, but laser drift, mechanical acceleration and missed branches require their own models. Report the time interval over which a constant velocity is being claimed.

Recover a small vibration amplitude from optical sidebands

A phase-sensitive receiver is not the only way to recover periodic motion. Let a mirror vibrate at angular frequency \(\Omega\) about a fixed mean, with displacement \(A\cos\Omega t\) and speed sufficiently small for a first-order optical path description. The reflected analytic signal relative to its carrier contains \(e^{im\cos\Omega t}\) with modulation index \(m=4\pi A/\lambda_0\). Expand the exponential in its Fourier series. The power of sideband order \(j\) relative to the incident unmodulated carrier is \(J_j(m)^2\), where \(J_j\) is a Bessel function. Energy conservation of the phase factor requires that all the sideband powers sum to one in this phase-only approximation.

For a 10.0 nm displacement amplitude at 633 nm the index is 0.1985. To leading small-index order, each first sideband carries \((m/2)^2=0.00985\) of the original carrier power. The central component loses approximately twice this amount. A receiver collecting only one sideband would infer the wrong vibration amplitude if it treated that signal as the sum of both. At larger amplitudes higher Bessel orders become important and a single sideband amplitude is no longer a monotone function of displacement. A multi-sideband fit or an independent coarse amplitude resolves the ambiguity.

With a balanced optical heterodyne reference offset far enough from zero frequency, both sidebands can be separated electronically from the carrier beat. Measuring their power ratio to the central beat cancels a common optical gain, but any electronic response slope between their frequencies needs calibration. Pure phase modulation predicts symmetric sideband powers. Asymmetry can arise from simultaneous amplitude modulation or an unequal frequency response rather than from a change in mirror speed. Measuring their complex phases distinguishes amplitude and phase modulation more directly.

A useful consistency check uses three independent measured quantities. Infer displacement amplitude from the first two sidebands, obtain the mechanical frequency from their separation and predict peak Doppler beat from the product of those two values. Then compare with a separate unwrapped quadrature phase trace. For a rigid sinusoidal mirror these should agree within timing and wavelength uncertainties. An interferometric signal containing two different moving surfaces can fit a few sideband powers yet fail the predicted time-dependent phase; changing the illuminated spot or one surface position tests that possibility. A spectrum and a time trace jointly constrain motion in a way that a single fringe visibility cannot.

Tutorial · Resolve a branch ambiguity in a vibrating mirror

A mirror returns a signed mean beat of 8.0 kHz while moving uniformly over a short time window. The vacuum wavelength is 632.8 nm. The detector samples quadrature at 10.0 kHz and a naive nearest-branch unwrap reports minus 2.0 kHz. Explain the discrepancy, infer both candidate speeds and design a measurement to select the correct one.

Track the sampled phase and use an independent constraint

A true phase advance of 0.80 cycle per sample is indistinguishable from minus 0.20 cycle per sample when only consecutive wrapped angles are available. The corresponding physical speeds are plus 2.531 mm/s and minus 0.6328 mm/s. Both give exactly the same ideal complex samples at that sampling rate under the first-order laboratory formula. A smaller least-squares residual on one constant-speed branch cannot resolve the ambiguity without another observation.

Increase the sampling frequency above 16 kHz with margin or use an independently known direction and bounded speed range that excludes alternative aliases. A second wavelength also changes the beat while preserving physical velocity and can resolve the branch if the two ambiguous frequency ladders do not coincide over the admissible range. For accelerated motion verify the condition at the maximum instantaneous beat rather than at its signed average over a complete vibration period.

Tutorial · Can this beat measurement verify a relativistic correction?

A translation standard operates at 1.00 m/s and an interferometer at 500 nm records a nominal 4.00 MHz beat. Estimate the difference between exact and first-order vacuum predictions. A timebase has a fractional uncertainty \(10^{-8}\), and wavelength is uncertain by \(2\times10^{-8}\). Assess the test and state one way to reject an offset without confusing it with the desired correction.

Calculate the small difference without subtracting nearly equal optical frequencies

Use the exact beat formula or expand it directly. The correction is approximately \(-2v^2/(\lambda_0c)=-0.0133\) Hz for the receding mirror. The stated timebase contributes 0.040 Hz and the wavelength scale contributes 0.080 Hz to a 4 MHz prediction, even before including the velocity standard or alignment. This setup does not resolve the correction with those absolute uncertainties. Subtracting two floating-point optical frequencies near hundreds of terahertz is also a poor numerical route to such a small difference.

Reverse the velocity with equal magnitude. The leading signed beat is odd in velocity, while its leading relativistic correction is even. Adding the two signed beats cancels the ideal leading term and leaves about minus 0.0267 Hz. This reversal also preserves a fixed electronic frequency offset, which would add twice to the same sum. Take stationary-mirror reference readings and vary the speed magnitude; the wanted even term scales as speed squared. Different arm alignments or asymmetric velocity calibration during reversal can still imitate part of that effect.

Cambridge Electromagnetism · wave propagation, radiation momentum and Lorentz transformations

Where momentum waits between source and receiver

Derive the electromagnetic momentum balance, trace light pressure through a finite pulse, and account for the angular impulse when a magnetic flux decays.

Give a region a mechanical and a field account

Charges respond to Lorentz force density \(\mathbf f=\rho\mathbf E+\mathbf J\times\mathbf B\). To predict the total force on enclosed matter, one can measure the fields on a surrounding vacuum surface. First eliminate the sources. In vacuum Gauss’s law gives \(\rho=\epsilon_0\nabla\cdot\mathbf E\), and the Ampère–Maxwell law gives

\[\mathbf J=(\nabla\times\mathbf B)/\mu_0-\epsilon_0\partial_t\mathbf E.\]

Introduce \(\mathbf g=\epsilon_0\mathbf E\times\mathbf B=\mathbf S/c^2\). Its time derivative supplies both \(\epsilon_0\partial_t\mathbf E\times\mathbf B\) and \(\epsilon_0\mathbf E\times\partial_t\mathbf B\). The first cancels the displacement-current term in the force; Faraday’s law rewrites the second.

For example, the electric terms now read \(\epsilon_0[\mathbf E(\nabla\cdot\mathbf E)-\mathbf E\times(\nabla\times\mathbf E)]\). Component \(i\) is \(\partial_j[\epsilon_0(E_iE_j-\delta_{ij}E^2/2)]\), with repeated Cartesian indices summed. The magnetic terms have the same form because \(\nabla\cdot\mathbf B=0\). Integration gives

\[T_{ij}=\epsilon_0(E_iE_j-\tfrac12 E^2\delta_{ij})+\frac1{\mu_0}(B_iB_j-\tfrac12 B^2\delta_{ij}),\]
\[\mathbf F_{\rm matter}=\oint T\mathbf n\,dA-\frac d{dt}\int\mathbf g\,dV .\]

The normal points out of the chosen volume. Positive \(T_{xx}\) denotes tension along \(x\) in this convention. For a wave travelling in \(+x\) with transverse fields, \(T_{xx}=-u\), where \(u\) is energy density. On an inlet whose outward normal is \(-\hat{\mathbf x}\), the normal traction therefore points in \(+x\).

Measure the time before light reaches a detector

A finite plane pulse in vacuum has \(|\mathbf S|=cu\). Its total momentum is \(U/c\) along the propagation direction. Surround a freely absorbing target and a length of initially empty space upstream with a vacuum control surface. While a pulse enters but has yet to reach the target, the inlet stress integral is nonzero. The electromagnetic momentum inside grows at exactly the same rate. The minus time derivative in the total force cancels the inlet contribution and the target has zero force during this interval.

Worked optical impulse

A 0.60 mJ pulse is fully absorbed after crossing the inlet. Initially and finally the region contains no pulse. Integrating the balance over that full time removes the stored-field term. The target gains \(0.60\times10^{-3}/c=2.00\times10^{-12}\) N s. For ideal normal reflection the exiting pulse carries the opposite momentum, giving twice that impulse. For a transparent window with parallel faces at normal incidence the outgoing pulse may eventually have the same vacuum momentum as the incoming pulse, while the two faces still experience transient forces.

Convert distributed field momentum into a turning impulse

Now take a long coaxial arrangement: an inner narrow cylindrical shell of radius \(a\) carries free charge \(+\lambda\) per length; an outer shell of radius \(b\) carries \(-\lambda\). There is a uniform axial magnetic field \(B_0\) over the annular gap, with end effects negligible. For a definite preparation take an ideal long solenoid producing uniform field throughout \(r<b\), and confine the initial electric field to the gap. Between shells \(E_r=\lambda/(2\pi\epsilon_0 r)\). The field momentum density points towards negative azimuth because \(\hat{\mathbf r}\times\hat{\mathbf z}=-\hat{\boldsymbol\phi}\).

\[g_\phi=-\lambda B_0/(2\pi r),\]
\[L_{{\rm field},z}'=\int_a^b r g_\phi\,2\pi r\,dr=-\tfrac12\lambda B_0(b^2-a^2).\]

The prime denotes angular momentum per length. While the coil current decays slowly, Faraday’s law gives \(2\pi r E_\phi=-\pi r^2\dot B\) for radii up to \(b\). The torque on each shell per length is \(r\lambda_{\rm shell}E_\phi(r)\). Integrating from \(B_0\) to zero yields \(+\lambda B_0a^2/2\) on the inner shell and \(-\lambda B_0b^2/2\) on the outer. Their sum reproduces the initial field angular momentum. Clamps would receive those impulses if the shells were held fixed.

Worked sign and magnitude

With \(\lambda=20\) nC/m, \(B_0=0.25\) T, \(a=10\) mm and \(b=30\) mm, the initial \(L'_z=-2.0\times10^{-12}\) kg m/s. That is angular momentum per metre of apparatus. The outer shell receives nine times the inner impulse magnitude and rotates in the opposite sense. Torque from the induced azimuthal electric field supplies this transfer even though both shells started at rest.

Transfer angular momentum from a field into two shells

The inner radius is 10 mm and its line charge is +20 nC/m. For a 30 mm outer radius and an initial field of 0.25 T, the final shell impulses are +0.25 and −2.25 in units of 10⁻¹² kg m/s. Trace the four accounts during switch-off.

Choose a control surface for momentum

Find a pressure when transmission and reflection coexist

A normal beam of intensity 300 W/m² reaches a free-standing film in vacuum. Reflected power fraction is 0.20 and transmitted fraction is 0.50. Find the time-averaged pressure and identify the momentum carried away.

Work through the solution

With incident direction positive, outgoing momentum per area and time is \((T-R)I/c\). The deposited amount is

\[(1-T+R)I/c=0.70(300)/c=0.700\,\mu{\rm Pa}.\]

The absorbed part contributes \(0.30I/c\) and reflection adds \(0.40I/c\). The result assumes forward and backward beams remain normal to the film.

Reverse just the charges

In the coaxial example reverse both shell charges while keeping the axial field and current decay unchanged. Which quantities reverse?

Work through the solution

The radial field, stored azimuthal momentum and angular momentum reverse. Faraday’s induced \(E_\phi\) follows the same history because the flux decay is unchanged. Each electric force and angular impulse reverses since the charge signs reverse. This independent sign argument checks the cross product in the original momentum density.

Practicum · audit a pulse bouncing inside a partly absorbing cavity

A shutter has just prepared a short \(U_0=1.20\) mJ pulse travelling to the right in an otherwise empty one-dimensional cavity. Start the accounting after preparation. The left mirror reflects perfectly. At every encounter with the right mirror 60% of incident pulse energy is reflected, 30% passes into vacuum on the right, and 10% is absorbed. Pulse duration is short compared with the flight time across the cavity. Mirrors are mounted on massive force probes; neglect their displacement and delay any re-emission of heat. The challenge is to reconcile two large, oppositely signed readings with a small net impulse.

Audit one encounter and decide which surface terms matter

For energy \(U\) just before an encounter with the right mirror, calculate its mechanical impulse. Then find the impulse when the reflected packet hits the left mirror. Which momentum is still present between those events?

Follow the calculation and check the result

The incoming momentum is \(+U/c\). The two outgoing packets carry \(+0.30U/c\) and \(-0.60U/c\). Momentum balance therefore assigns the right mirror \(+(1-0.30+0.60)U/c=+1.30U/c\). This includes reversing the reflected packet and stopping the absorbed packet. The left mirror receives \(-2(0.60U)/c=-1.20U/c\) at the next collision. Between those events the cavity still contains \(-0.60U/c\) of field momentum. The complete system also contains the \(+0.30U/c\) transmitted packet outside the cavity.

Stop the movie at a specified time

Freeze the experiment just after the third right-mirror encounter and before the next left-mirror encounter. Find the remaining energy, radiated output, deposited heat, both probe impulses, and total field momentum.

Follow the calculation and check the result

Three incident energies in units of \(U_0\) form the sequence \(1,0.6,0.36\). Their sum is 1.96. The output energy is \(0.30(1.96)U_0=0.588U_0\), heat is \(0.196U_0\), and \(0.216U_0\) remains. The three fractions sum to unity. Right-probe impulse is

\[+1.30(1.96)U_0/c=+2.548U_0/c.\]

Only two left reflections have occurred, so the left probe reads \(-2(0.60+0.36)U_0/c=-1.920U_0/c\). Their sum is \(+0.628U_0/c\).

The escaped packets carry \(+0.588U_0/c\), but the packet still inside carries \(-0.216U_0/c\). Including these two contributions gives measured plus field momentum \((0.628+0.588-0.216)U_0/c=U_0/c\), the initial value. Counting a third left-hand reflection at this time would violate the preselected event boundary. Since \(U_0/c=4.00\times10^{-12}\) N s, the probe readings are approximately \(+10.2\) and \(-7.68\) pN s.

Sum the full history in two independent ways

Continue until no macroscopic pulse remains. Find the impulse on each mirror, then derive their combined reading directly from exterior measurements without examining any reflection.

Follow the calculation and check the result

The geometric series of right hits sums to \(U_0/(1-0.6)=2.5U_0\). The right impulse is \(3.25U_0/c\). Summing every left hit gives

\[-2(0.60)U_0/[(1-0.60)c]=-3.00U_0/c.\]

Thus the pair receives \(+0.25U_0/c\). All transmitted packets travel right and together carry \(0.30U_0/(1-0.60)=0.75U_0\). An external vacuum control surface therefore gives \((1-0.75)U_0/c\) immediately. The absorbed \(0.25U_0\) accounts for the energy stored as heat.

A detector without enough time resolution can recover the integrated exterior momentum even though it cannot resolve the alternating internal forces. Conversely, two large internal probe signals can coexist with a modest net exterior impulse. In a numerical time march record separate signed transfers and the energy still in flight after each boundary update, then vary the stopping time. A budget that closes only after the very last encounter cannot diagnose an intermediate sign mistake.

Further reading

Why a small transparent sphere scatters light

A particle can redistribute light without consuming it. The calculation starts with an electrostatic boundary-value problem and ends with power crossing a faraway sphere. Connecting the two limits predicts a wavelength dependence that can be tested with colour.

Find the induced dipole by matching two potentials

Take a sphere of radius \(a\) and relative permittivity \(\epsilon_r\) in vacuum. Its size must be small compared with the wavelength everywhere, including inside the particle. Across its diameter, the incident wave then looks almost like a uniform electric field \(E_0\hat{\mathbf z}\). Spherical symmetry and the applied field single out the angular factor \(\cos\theta\). Choose \(\phi_{\rm in}=-Cr\cos\theta\) and \(\phi_{\rm out}=-E_0r\cos\theta+D\cos\theta/r^2\). Continuity of tangential electric field is equivalent here to continuity of potential. With zero free surface charge, the normal displacement is also continuous. At \(r=a\),

\[C=E_0-D/a^3,\]
\[\epsilon_r C=E_0+2D/a^3.\]

Eliminate \(C\) to obtain

\[D=a^3E_0(\epsilon_r-1)/(\epsilon_r+2).\]

The coefficient of the dipole potential is \(p/(4\pi\epsilon_0)\). Hence \(p=\alpha_0 E_0\) with \(\alpha_0=4\pi\epsilon_0a^3(\epsilon_r-1)/(\epsilon_r+2)\). The internal field \(3E_0/(\epsilon_r+2)\) explains the denominator. For \(\epsilon_r=1\) the disturbance vanishes. In the perfectly polarizable limit the internal field tends to zero.

Match a small dipole to an outgoing wave

Use complex amplitudes with time dependence \(e^{-i\omega t}\). The far electric field is \((k^2/4\pi\epsilon_0 r)[(\hat{\mathbf n}\times\mathbf p)\times\hat{\mathbf n}]e^{ikr}\), \(k=\omega/c\). Squaring its amplitude and multiplying by \(\epsilon_0 c/2\) gives the mean intensity. Divide by the incident intensity \(\epsilon_0c|E_0|^2/2\). The differential scattering cross section is then \(k^4|\alpha|^2\sin^2\theta/(16\pi^2\epsilon_0^2)\), with \(\theta\) measured from the dipole axis. Integrating the angular factor gives \(8\pi/3\):

\[\sigma_{\rm sca}=\frac{k^4|\alpha|^2}{6\pi\epsilon_0^2}\simeq\frac{8\pi}3 k^4a^6\left|\frac{\epsilon_r-1}{\epsilon_r+2}\right|^2 .\]

The sixth power originates in the coherent addition of dipoles throughout a volume proportional to \(a^3\). The fourth power in frequency comes from the second time derivative of the dipole in the radiative electric field. A cross section has units of area and measures removed power divided by incident intensity.

Where the scattered energy comes from

The incident field does work at mean rate \(\langle\mathbf E\cdot\dot{\mathbf p}\rangle=(\omega/2)\operatorname{Im}(\alpha)|E_0|^2\). Dividing by incident intensity yields

\[\sigma_{\rm ext}=k\operatorname{Im}(\alpha)/\epsilon_0.\]

A strictly real electrostatic \(\alpha_0\) would predict no extracted power while predicting positive scattered power. The static calculation captured the leading dipole amplitude but omitted its small radiation-induced phase delay. For a lossless electric dipole its leading radiative correction satisfies

\[\frac1\alpha=\frac1{\alpha_0}-i\frac{k^3}{6\pi\epsilon_0}.\]

Indeed \(\operatorname{Im}\alpha=k^3|\alpha|^2/(6\pi\epsilon_0)\), making extinction equal to scattering. In an absorbing particle their difference is absorbed power per incident intensity. Finite-size dispersion and higher multipoles require additional terms once \(ka\) grows.

Size, colour and the limits of inference

A particle doubles in radius

For dilute spheres of the same weakly dispersive material, doubling \(a\) gives \(2^6=64\) times the scattered power per particle at fixed incident intensity. If the total volume of dielectric is held fixed, the number of spheres falls by eight. The whole sample then scatters eight times the power, provided phases between different particles are effectively uncorrelated and multiple scattering is negligible. The two questions describe different samples.

A frequency-independent contrast

For \(a=20\) nm, \(\epsilon_r=2.25\) and vacuum wavelength \(600\) nm, \(ka=0.209\) and \((\epsilon_r-1)/(\epsilon_r+2)=0.2941\). The leading cross section is \(5.58\times10^{-19}\) m², around \(4.4\times10^{-4}\) of the geometric area. At \(450\) nm the model predicts 3.16 times that cross section. A large discrepancy can indicate dispersion, additional multipoles, or a distribution of particle sizes.

Compare the scattering of several particle sizes

For radius 20 nm, relative permittivity 2.25 and wavelength 600 nm, the predicted cross section is about 0.56 nm². Halve the radius and estimate the drop before reading the plot. The curve uses a frequency-independent dielectric contrast.

Problem sheet · inverse measurements

Estimate a radius ratio

Two dilute suspensions have the same number density, composition and optical path length. In the single-scattering regime one produces twice the scattered intensity at the same angle. Infer the ratio of particle radii.

Work through the solution

The proportionality to \(a^6\) gives

\[a_2/a_1=2^{1/6}=1.122.\]

A 12.2% change in radius doubles the signal. If counts or material contrasts are unknown, the same intensity change has multiple explanations.

Recover Thomson scattering

A free electron is driven by a weak field. Use \(m\ddot x=-eE_0e^{-i\omega t}\) to find its dipole and cross section. Why does the wavelength law change?

Work through the solution

The displacement amplitude is \(eE_0/(m\omega^2)\). Multiplying by electronic charge gives

\[\alpha=-e^2/(m\omega^2).\]

The \(\omega^{-4}\) in \(|\alpha|^2\) cancels \(k^4\). The cross section becomes \((8\pi/3)[e^2/(4\pi\epsilon_0mc^2)]^2\). This classical approximation assumes nonrelativistic electron motion and negligible recoil.

Further reading

From wavefronts to rays, focusing and caustics

A ray is a prediction extracted from the phase of a wave. Following its amplitude at the same time reveals the point at which a ray calculation loses its validity. A gently graded transparent material gives a solvable example of both effects.

Derive the phase and transport equations together

In a lossless isotropic dielectric with a slowly varying refractive index \(n(\mathbf r)\), consider one scalar polarisation component satisfying \(\nabla^2\psi+k_0^2 n^2\psi=0\), where \(k_0=\omega/c\). This scalar description works when vector-polarisation coupling is negligible over the scales of interest. Set \(\psi=A(\mathbf r)e^{ik_0S(\mathbf r)}\) with a slowly varying real amplitude. Differentiation twice gives

\[0=\nabla^2 A+i k_0[2\nabla A\cdot\nabla S+A\nabla^2S]+k_0^2 A(n^2-|\nabla S|^2).\]

If the material and amplitude vary little over a wavelength, first equate the leading \(k_0^2\) term to zero. At the next order the \(k_0\) term vanishes. The two results are the eikonal equation and transport equation:

\[|\nabla S|^2=n^2,\]
\[\nabla\cdot(A^2\nabla S)=0 .\]

The first fixes the optical length accumulated between neighbouring wavefronts. The second transports energy down a thin ray tube. Across a tube of area \(\mathcal A\) perpendicular to the phase gradient, \(A^2 n\mathcal A\) is constant to this order. In a uniform medium a spherical tube grows as \(r^2\), giving \(A\propto1/r\), consistent with the outgoing wave.

Follow the normal to a wavefront

Choose arclength \(s\) along the ray and \(\hat{\mathbf t}=\nabla S/n\). In the eikonal equation take a spatial derivative. Since \(\nabla S\) is a gradient,

\[(\nabla S\cdot\nabla)\nabla S=\nabla(|\nabla S|^2)/2=n\nabla n.\]

Divide by \(n\). The ray equation is

\[\frac{d}{ds}(n\hat{\mathbf t})=\nabla n .\]

A transverse increase of index bends the ray toward larger optical index. If \(n\) depends only on the coordinate normal to layers, the component of \(n\hat{\mathbf t}\) parallel to them stays constant. Thus \(n\sin\theta\) is conserved for an angle measured from the normal, recovering Snell's law. The same equation follows by requiring stationary optical length \(\int n\,ds\) when varying the path with fixed endpoints.

Solve a graded-index profile

For paraxial rays travelling close to \(+z\), take \(n(y)\simeq n_0(1-g^2y^2/2)\). Assume \(|gy|\ll1\) and \(|dy/dz|\ll1\). Then \(ds\simeq dz\), \(\hat t_y\simeq y'\), and \(d(ny')/dz\simeq n_0y''\) to leading order. Since \(\partial_y n=-n_0g^2y\), the trajectory solves \(y''+g^2y=0\). Initial height \(y_0\) and slope \(s_0\) give

\[y(z)=y_0\cos(gz)+\frac{s_0}{g}\sin(gz),\]
\[y'(z)=-g y_0\sin(gz)+s_0\cos(gz).\]

For a collimated bundle, all \(s_0=0\). The transverse magnification \(\partial y/\partial y_0=\cos(gz)\) vanishes simultaneously for all rays at \(z_f=\pi/(2g)\). This is a caustic of the ray description. In this planar example the ray density grows as \(1/|\cos(gz)|\). Its divergence signals that the neglected \(\nabla^2 A\) becomes important. The underlying wave stays finite and develops diffraction near the focus.

A focus and a reconstructed gradient

Refocus an off-axis bundle

Take \(g=20\ {\rm m^{-1}}\), initial heights between \(-1\) and \(+1\) mm and zero slopes. The predicted first focus is \(78.5\) mm downstream. The extreme rays acquire slopes of magnitude \(0.020\) at the focus, well within the paraxial regime. Tilt every initial ray by 0.010 rad. At \(z_f\) the common height shifts to \(s_0/g=0.50\) mm. The focal length is insensitive to this common tilt in the parabolic approximation.

Estimate the index from a photograph

Two successive crossings of initially parallel symmetric rays are 120 mm apart. Crossings occur at \(gz=\pi/2+m\pi\), so

\[g=\pi/0.120=26.2\ {\rm m^{-1}}.\]

At a height of 2 mm, the predicted fractional index decrease from the central index is

\[g^2y^2/2=1.37\times10^{-3}.\]

Resolving this small contrast through repeated bending can be easier than resolving it through a single refraction measurement.

Focus and tilt a bundle of paraxial rays

At gradient 20 m⁻¹, five parallel rays meet after 78.5 mm. A common tilt of 10 mrad displaces their meeting point by 0.50 mm. Follow the bundle through a crossing and decide why the geometric density ceases to predict a finite intensity there.

Problem sheet · optical path and diffraction

A travel-time check

A ray passes through two homogeneous layers of thicknesses \(a,b\), indices \(n_1,n_2\), with lateral endpoint separation \(D\). Write travel time as a function of crossing coordinate \(x\). Recover the interface condition.

Work through the solution

The time is

\[T(x)=[n_1\sqrt{a^2+x^2}+n_2\sqrt{b^2+(D-x)^2}]/c.\]

The derivative vanishes when \(n_1 x/\sqrt{a^2+x^2}=n_2(D-x)/\sqrt{b^2+(D-x)^2}\). The two fractions are the sines of the angles to the interface normal. Each segment's length has positive second derivative, making this stationary path a local minimum in this geometry.

Estimate the diffraction scale

A circular pupil of numerical aperture 0.030 focuses vacuum light of wavelength 600 nm. Estimate the first dark-ring radius and compare it with a ray focus.

Work through the solution

For a uniformly illuminated circular aperture in the paraxial limit the first Airy minimum is \(0.61\lambda_0/\mathrm{NA}\), giving \(12.2\) μm. Different pupil shapes change the numerical factor. The wavelength dependence is absent from the ray crossing, so a ray trace alone cannot distinguish two experiments with identical geometry but different wavelengths.

Further reading