Start from what a polarising analyser measures
Take a quasi-monochromatic beam propagating in a fixed direction, resolved in transverse axes \(x,y\). Use complex field amplitudes with time factor \(e^{-i\omega t}\). Absorb common power and impedance factors into their units. The time- or ensemble-averaged coherency matrix \(J=\langle\boldsymbol E\boldsymbol E^\dagger\rangle\) has four real degrees of freedom because it is Hermitian. An analyser selecting the normalised complex state \(\boldsymbol a\) passes amplitude \(\boldsymbol a^\dagger\boldsymbol E\) and measures \(I_a=\boldsymbol a^\dagger J\boldsymbol a\). Thus every analyser projects the same matrix onto a distinct polarisation.
Choose \(S_0=J_{xx}+J_{yy}\), \(S_1=J_{xx}-J_{yy}\),
For this convention the state \((1,i)/\sqrt2\) has positive \(S_3\). Naming it by its explicit Jones vector avoids a handedness ambiguity between observer viewing directions. Inverting those definitions gives
Horizontal and vertical linear analysers therefore give \((S_0\pm S_1)/2\). The \(+45^\circ,-45^\circ\) pair gives \((S_0\pm S_2)/2\). The circular pair \((1,\pm i)/\sqrt2\) gives \((S_0\pm S_3)/2\). Every pair sum recovers total intensity, providing an internal calibration check. Subtracting the complementary measurements cancels a common additive detector offset in each Stokes difference, though \(S_0\) still needs a dark correction.
Derive the physically allowed domain
Because \(I_a\ge0\) for every analyser, both eigenvalues of \(J\) are nonnegative. Solve its quadratic characteristic equation using the trace \(S_0\) and determinant \((S_0^2-S_1^2-S_2^2-S_3^2)/4\). The eigenvalues are \((S_0\pm|\boldsymbol S|)/2\), where \(\boldsymbol S=(S_1,S_2,S_3)\). Consequently \(P=|\boldsymbol S|/S_0\) lies between zero and one for a beam with nonzero intensity. A single fully polarised Jones state gives rank one and \(P=1\). An incoherent mixture of two orthogonal states of equal intensity has \(J=(S_0/2)I\) and \(P=0\).
Suppose a corrected data set gives \(I_x,I_y=70,30\); \(I_{+45},I_{-45}=65,35\); \(I_+,I_-=60,40\) in the same units. The pair sums agree at 100. Reconstructed parameters are \((100,40,30,20)\), giving \(P=\sqrt{2900}/100=0.539\). The eigenvalues are 76.93 and 23.07. Subtracting the smaller times the identity leaves a rank-one contribution of intensity 53.85 and an unpolarised remainder of intensity 46.15. This decomposition describes the observed second moments; several microscopic preparations can produce the same \(J\).
Predict a rotating analyser and identify its blind spot
For \(\boldsymbol a=(\cos\alpha,\sin\alpha)\), expanding the projection and using double-angle identities gives
A linear analyser alone is blind to \(S_3\), even when sampled at hundreds of angles. In the example the extrema are \(50\pm25\), with the maximum at \(\alpha=\frac12\operatorname{atan2}(30,40)=18.43^\circ\). The linear fringe visibility 0.50 is slightly below the total degree 0.539. Inserting a quarter-wave plate with Jones matrix \(\operatorname{diag}(1,-i)\) before the same analyser transforms \(S_2\) into \(S_3\) in the intensity formula. One can now obtain the previously hidden signed correlation from readings at \(45^\circ\) and \(135^\circ\).
The experiment prepares an adjustable polarised fraction with azimuth \(\psi\) and ellipticity angle \(\chi\), mixed with an unpolarised background. Its normalised Stokes vector is \(P(\cos2\chi\cos2\psi,\cos2\chi\sin2\psi,\sin2\chi)\). Make the unassisted intensity scan flat by choosing circular polarisation, then insert the fixed retarder virtually and predict the recovered difference. Setting \(P=0\) makes both scans flat. This comparison shows which measurement discriminates the two cases.
Tutorial on instrument design
A linear scan alone has \(I_{\max}=75,I_{\min}=25\). Give the range of total degrees of polarisation allowed and the maximum possible magnitude of \(S_3\).
Work through the solution
The linear magnitude is 50 and \(S_0=100\). Thus \(0.5\le P\le1\), and the positivity bound gives
A circular analyser measurement fixes the remaining magnitude and sign.
An ideal beam contains 60 units of pure horizontal light and 40 units of unpolarised light. Compare its Stokes vector with a coherent superposition of horizontal and vertical components with intensities 80 and 20 and zero relative phase.
Work through the solution
The incoherent mixture has \((100,60,0,0)\) and \(P=0.6\). The coherent preparation has \((100,60,80,0)\) since \(2\sqrt{80\times20}=80\), and \(P=1\). Their horizontal and vertical readings coincide. A diagonal analyser gives 50 for the mixture and 90 for the coherent preparation.
All three measured component differences equal 70 at measured total 100. Can a physical beam have these parameters?
Work through the solution
They imply \(|\boldsymbol S|=70\sqrt3=121.2>S_0\) and a negative matrix eigenvalue. Check dark subtraction, gain calibration, alignment and whether the source changed between readings. A physical fit with stated uncertainties is required before interpreting the data as an optical state.
Further reading · ETH Zürich, Stenflo on coherency and Stokes parameters.
Study the full derivation
What an analyser measures about polarisation and coherence · Waves, radiation and relativity
Two red beams produce the same reading through every rotating linear polarizer. One might be circularly polarized and the other an incoherent mixture. Build the measurements that distinguish them, derive the visibility of their interference fringes, and decide which information is lost on a slow detector.