Fundamentals / Physics / Quantum mechanics / Computational quantum experiments

Which part of a Bell correlation survives imperfect state preparation?

A source emits two spin-half systems in the singlet state. Two observers select measurement directions separately and record outcomes \(+1\) or \(-1\). Construct a Bell–CHSH statistic from four measurable correlations and determine how state preparation, angular alignment and finite sample size affect the prediction.

Relate a counted coincidence to an operator

Denote unit measurement directions by \(\mathbf a,\mathbf b\). Outcome projectors are \((1+s\,\boldsymbol\sigma\cdot\mathbf a)/2\) and \((1+t\,\boldsymbol\sigma\cdot\mathbf b)/2\), for \(s,t=\pm1\). The singlet has zero individual spin expectation and tensor \(\langle\sigma_i\otimes\sigma_j\rangle=-\delta_{ij}\). The diagonal entries follow because measurements along any common axis are exactly opposite and the state is rotationally invariant. Its joint probability is

\[p(s,t|\mathbf a,\mathbf b)=\tfrac14(1-st\,\mathbf a\cdot\mathbf b),\]
\[E(\mathbf a,\mathbf b)=-\mathbf a\cdot\mathbf b.\]

Summing over either outcome leaves one half for the other observer, independent of the remote angle. Covariance can change while the individual counting rates remain constant. At an angle of 60 degrees the probabilities of the two equal-outcome combinations sum to one quarter, and of opposite outcomes to three quarters. Their signed difference gives −0.5. The lab models spin-axis angles; linear polarisation analysers give a doubled angle in their effective two-state representation.

Derive a bound and choose a set of directions

If a trial had four predetermined local binary responses \(A,A',B,B'\), its combination \(AB+AB'+A'B-A'B'=A(B+B')+A'(B-B')\) would have magnitude two, since exactly one of the parentheses vanishes. Averaging over a common distribution of such assignments preserves the bound. The quantum prediction combines expectation values measured on different subensembles with independently chosen setting pairs. Use coplanar angles \(a=0,\ a'=\pi/2,\ b=\theta,\ b'=-\theta\).

\[S=E(a,b)+E(a,b')+E(a',b)-E(a',b')=-2(\cos\theta+\sin\theta).\]

At \(\theta=45^\circ\) its magnitude is \(2\sqrt2\). The derivative vanishes there, making small symmetric angular errors second order. If a fraction \(1-v\) of pairs is completely unpolarised, the density operator is \(v|\Psi^-\rangle\langle\Psi^-|+(1-v)I/4\). Every correlator gains a factor \(v\). The best attainable magnitude exceeds two only when \(v>1/\sqrt2\). This is a statement about this measurement family and this noise model. A pair source and a scalar contrast alone do not define an experimental protocol.

Assess one set of finite counts

At \(v=0.80\), \(\theta=45^\circ\) the expected magnitude is about 2.263. Each trial product is a binary variable with variance \(1-E^2\). For \(N\) independent pairs per setting, the sample correlation variance is \((1-E^2)/N\). Assuming independent subensembles, variance of the signed sum is the sum of the four variances. Here every squared correlation is 0.32. With 1000 trials per setting the approximate standard error of the statistic is

\[\sqrt{4(1-0.32)/1000}=0.0522.\]

The excess 0.263 is roughly five standard errors under this idealised independent-trial model. It is not a substitute for a finite-sample hypothesis test that accounts for an actual protocol's setting choices, losses, timing and possible memory.

Change settings and preparation independently

Inspect the predicted absolute statistic and the local assignment bound. Find the angles for which the chosen source can exceed two. Then vary visibility at a fixed angle. Small individual spin polarisation drifts could alter the marginal counts; unequal channel efficiencies could change a coincidence-selected sample. Monitoring all four joint count tables and both single-observer marginal distributions allows more checks than retaining only their final sum.

Tutorial

At visibility 0.70, can increasing the number of trials eventually make the expected maximum exceed two?

Work through the solution

No. The largest mean value is \(2\sqrt2(0.70)=1.980\). More trials narrow the sampling distribution around that value. Changing the preparation or measurement family addresses a different question.

What is the predicted fractional loss at an angle \(\delta\) away from the optimum, and how large is it at five degrees?

Work through the solution

Write \(\cos\theta+\sin\theta=\sqrt2\cos(\theta-\pi/4)\). The fractional loss is \(1-\cos\delta\), about \(0.00381\) at five degrees. Asymmetric offsets on different analyser axes need not enter the same way.

A paper gives one large value of \(|S|\) but discards all pairs for which one detector was silent. Can the ideal bound derived above automatically be applied to these retained counts?

Work through the solution

The derivation averaged all setting pairs over a common underlying ensemble. Setting- or state-dependent retention can alter those ensembles. One needs the trial definition, data handling and efficiency assumptions to interpret the reported statistic.

For state preparation and independent measurement on tensor factors, revisit the composite-state chapter.