Follow a normalised state as its allowed box grows
Consider a particle moving in one spatial dimension. A periodic box of length \(L\) is a mathematical model for an observation made far from any reflecting wall. The inner product is the integral of \(\psi^*(x)\chi(x)\) over the box. The momentum operator is \(-i\hbar\,d/dx\) with periodic boundary conditions. Integration by parts cancels its boundary form for periodic differentiable functions. Its normalised modes \(L^{-1/2}e^{ik_n x}\) have \(k_n=2\pi n/L\) and momenta \(p_n=\hbar k_n\). Their overlap is one if the integers coincide and zero otherwise. Increasing \(L\) reduces the spacing \(\Delta p=2\pi\hbar/L\) but also reduces the amplitude of each individual box mode at a fixed position. If one simply replaces the Kronecker delta by a Dirac delta while carrying over \(L^{-1/2}\), the units and probabilities will fail.
Let \(c_n\) be the unit-normalised amplitudes with \(\sum_n|c_n|^2=1\). For a smooth normalisable packet the probability in an interval \(dp\) has a limit \(|\phi(p)|^2 dp\). Thus \(c_n\simeq\sqrt{\Delta p}\,\phi(p_n)\). Substituting in the synthesis sum and using \(L\Delta p=2\pi\hbar\) produces
The distributions \(\langle x|p\rangle=(2\pi\hbar)^{-1/2}e^{ipx/\hbar}\) have \(\langle p|p'\rangle=\delta(p-p')\). The delta acts under integration; \(\delta(0)\) has no finite interpretation as the probability for a detector. A physical probability is \(\int_{p_1}^{p_2}|\phi(p)|^2dp\). Changing to wave number gives
A graph labelled density in \(k\) with a vertical axis copied directly from the momentum plot loses the Jacobian and in general ceases to normalise to one.
Change from momentum bins to energy bins
For a free particle \(E=p^2/(2m)\). Each positive energy has two distinct momenta \(p_\pm=\pm\sqrt{2mE}\). A detector measuring energy but not direction sums over these mutually orthogonal alternatives. Apply the ordinary change-of-variables rule on each monotone half-line:
The factor \(m/|p|\) is \(1/|dE/dp|\), with units of momentum per energy. Measuring a finite energy interval around zero can have a density diverging as \(E^{-1/2}\) if \(\phi(0)\ne0\), yet the integrated probability is finite because \(\int_0^\delta E^{-1/2}dE=2\sqrt\delta\). The same effect appears in a box as relatively dense low-energy modes. Standing-wave box boundary conditions change the counting of travelling directions; include degeneracy once and use the appropriate mode spacing, rather than doubling both.
On an infinite line it is useful to introduce \(|E,+\rangle=\sqrt{m/|p|}\,|p\rangle\) at \(p>0\), and a corresponding negative branch. In the overlap,
the two square-root factors give \(\delta(E-E')\). The resolution of identity contains \(\sum_{\pm}\int_0^\infty dE\,|E,\pm\rangle\langle E,\pm|\). Measuring energy while coherently manipulating the two degenerate directions requires keeping both amplitudes. Adding their probabilities is sufficient only for an instrument whose outcome identifies energy without mixing the directions before detection.
Integrate the free evolution of a Gaussian
Prepare a minimum-uncertainty wave packet centred at \(x_0\) with average momentum \(p_0\) and initial position standard deviation \(s\):
Its squared modulus is a Gaussian with variance \(s^2\), which explains the factor four in the amplitude exponent. Complete the square in the Fourier integral to find a momentum probability Gaussian centred at \(p_0\) of variance \(\hbar^2/(4s^2)\). The initial state has zero symmetrised position–momentum covariance. Multiplying by a chirp factor \(\exp[i\kappa(x-x_0)^2]\) leaves its initial position density unchanged but changes momentum variance and covariance. A snapshot of one density does not determine its later free spread.
Each momentum component evolves by \(e^{-ip^2t/(2m\hbar)}\). Split \(p=p_0+q\). The constant term in \(p^2\) produces a common phase; the linear term shifts the envelope by \(p_0t/m\); the quadratic term changes the width. Carrying out the remaining Gaussian integral yields
An independent route uses the Heisenberg operator \(x(t)=x(0)+p(0)t/m\). Its variance is \(s^2+(t/m)\langle\{\Delta x,\Delta p\}\rangle+(t/m)^2(\Delta p)^2\). Inserting zero covariance and the Gaussian momentum width reproduces \(s_t^2\). For a chirped packet the covariance term can be negative; momentary narrowing during free evolution is consistent with uncertainty because momentum width and the phase correlation must be included. The density integral stays one, so spreading lowers the height of the peak without removing particles.
Take a model atom of mass \(1.44\times10^{-25}\) kg prepared with \(s=1.00\,\mu\mathrm m\). Its spread time \(t_s=2ms^2/\hbar=2.73\) ms. At \(t=t_s\) the standard deviation is 1.41 μm. With mean velocity 2.00 mm/s its mean has advanced 5.46 μm. At long flight times \(s_t\simeq t\Delta p/m\). Measuring position after a known long flight therefore maps the momentum distribution for this free packet. At \(0.5t_s\) the neglected initial position variance is still dominant, so the same inference would substantially overestimate \(\Delta p\).
A detector window and a Fourier grid do different jobs
Suppose the position-sensitive detector has a Gaussian point-spread function of width \(d\). The measured density is a convolution of the true density with that response if detections are independent and gain is uniform. Gaussian variances then add:
This broadening belongs to the observation model; it does not increase the particle's momentum spread before the measurement. For \(d=1.20\,\mu\mathrm m\) at \(t=t_s\), the observed standard deviation becomes \(1.85\,\mu\mathrm m\). A fit to a single image with unknown \(d\) cannot disentangle the two contributions. A sequence of flight times constrains the coefficient of \(t^2\) independently of a fixed instrument width.
A discrete Fourier propagation represents a periodic interval sampled at spacing \(\Delta x\). Its wave-number spacing is \(2\pi/L\), and the highest resolved wave number is order \(\pi/\Delta x\). Enlarging \(L\) at fixed \(\Delta x\) samples the momentum profile more finely and delays periodic wraparound. Reducing \(\Delta x\) at fixed \(L\) raises the bandwidth without moving the periodic boundary. Either operation alone can leave the other error intact. A norm-preserving FFT propagator can therefore return a perfectly normalised wave packet that has wrapped through an unphysical boundary or whose carrier momentum has aliased. Compare the phase, group velocity and width against independent formulas, then refine the two scales separately.
Why boundary conditions are part of a momentum observable
The expression \(p=-i\hbar\,d/dx\) does not by itself specify a complete operator. On a finite interval \([0,L]\), integrate two sufficiently smooth square-integrable functions by parts:
A symmetric domain makes this boundary form vanish for every pair in the domain. A self-adjoint operator additionally has the same domain as its adjoint. This distinction matters for a physical generator of unitary translations and for assigning sharp spectral outcomes. Imposing a real or imaginary matrix representation in a finite basis can conceal boundary conditions that become essential as the basis is enlarged.
For a ring allow quasi-periodicity \(g(L)=e^{i\theta}g(0)\) with fixed \(\theta\) common to all functions in the domain and square-integrable first derivative. Then the boundary form vanishes. Conversely, for an adjoint candidate \(f\) the requirement that it vanish for all possible \(g(0)\) forces \(f(L)=e^{i\theta}f(0)\), so the same condition reappears. Solving \(p g=pg\) yields the momenta \(p_n=\hbar(2\pi n+\theta)/L\). Thus boxes with precisely the same local differential expression have momentum spectra shifted by an externally fixed phase. In a physically realised ring such a phase can encode a magnetic flux through a gauge-transformed boundary condition; a gauge consistent with that interpretation must also be used in the Hamiltonian and physical momentum.
Compare with forcing \(g(0)=g(L)=0\) as in a hard-wall well. The boundary form vanishes for all \(f,g\) satisfying both zero conditions, so the derivative is symmetric there. But the adjoint boundary form vanishes for arbitrary endpoint values of \(f\) when \(g\) vanishes at both ends. Consequently this two-zero derivative domain is smaller than its adjoint domain. There is no ordinary rigid translation that carries every state of a hard-wall interval back into that same interval without assigning what happens at its boundary. Meanwhile the kinetic energy \(-\hbar^2d^2/(2m\,dx^2)\) with suitable Dirichlet domain is self-adjoint and has a well-defined discrete spectrum. The symbol \(p^2/(2m)\) in a Dirichlet well does not turn its first derivative with the same two endpoint conditions into a self-adjoint sharp momentum observable.
A release-and-detect experiment makes this distinction concrete. Prepare the first Dirichlet state \(\sqrt{2/L}\sin(\pi x/L)\) supported in \(0<x<L\), then remove the walls suddenly and measure momentum on the full line. Its momentum wavefunction is the Fourier transform of the spatial function extended by zero outside. Multiplying the exponential and sine and integrating gives a continuous amplitude proportional to \([1+e^{-ipL/\hbar}]/[(\pi/L)^2-(p/\hbar)^2]\). The apparent singularities at \(p/\hbar=\pm\pi/L\) are removable because the numerator also vanishes. It is a mistake to predict two delta peaks by replacing the standing wave with the sum of two infinite plane waves. The finite support multiplies that sum by a spatial window and broadens both momentum components.
The mean momentum for this real function is zero. Its second moment after release is \(\hbar^2\int|\psi'|^2dx=\pi^2\hbar^2/L^2\), consistent with the original kinetic energy. Thus a continuous released momentum distribution can have an rms momentum whose square exactly recovers a discrete energy of the original bounded system. This is a useful quantitative example where the equality of moments across two measurement procedures does not imply equality of their full spectral probability distributions. Adding a short laboratory impulse to every particle after release should translate the whole distribution by the corresponding momentum kick, preserving its width. That response provides an independent check on a momentum detector's sign and scale.
Derive the free propagator with a convergent limiting prescription
Partitioning the free unitary into momentum eigenstates produces its position kernel
It is oscillatory rather than absolutely integrable. Define it by first damping \(e^{-\varepsilon p^2}\), evaluating a convergent Gaussian and then taking \(\varepsilon\downarrow0\) on smooth normalisable test packets. Completing the square in the exponent gives, for \(t>0\),
The phase convention of the square root for positive time follows continuously from the regularised Gaussian. The units are inverse length so \(\psi(x,t)=\int K(x,t;x',0)\psi(x',0)\,dx'\) has the same units as the initial wavefunction. As \(t\to0^+\), the kernel does not approach a finite spike pointwise. Its increasingly fast oscillations across \(x'\) cancel except near \(x'=x\), recovering the initial state in the appropriate strong or distributional sense. For a constant initial amplitude one may recover unity formally, but such an amplitude on the full line is itself not a normalised test state.
Two checks involve no wave packet fitting. Inserting two kernels for \(t_1,t_2\) and integrating over an intermediate position gives the kernel for \(t_1+t_2\), either by another Gaussian integration or, more directly, by composing the momentum phase factors. Complex conjugation and reversing the time arguments yield the inverse evolution. Neither statement holds for an arbitrary choice of magnitude prefactor assigned merely to obtain the correct phase. In Fourier numerics the corresponding checks are unit norm after repeated evolution and recovery of the original sampled complex state after a forward followed by backward propagation. These are necessary algorithm checks, even though a periodic or aliased computational model can still satisfy them exactly.
This kernel also clarifies the long-time momentum mapping. Factor \(e^{im x^2/(2\hbar t)}\) from \(K\) and identify the Fourier transform of \(e^{imx'^2/(2\hbar t)}\psi(x',0)\) evaluated at \(p=mx/t\). If the occupied initial region is narrow enough that \(mx'^2/(2\hbar t)\) varies little across it about the selected origin, the extra phase can be neglected and
The factor \(m/t\) is the Jacobian \(dp/dx\). When the initial packet is displaced, use a suitable shifted origin or account for the induced linear phase explicitly. This derivation applies well beyond Gaussians and gives a scale for testing the approximation before interpreting a flight image as a momentum histogram. The quadratic residual phase provides the matter-wave analogue of the near-field correction in diffraction.
Distinguish a detector crossing from a snapshot in space
A detector counts particles passing through an aperture over time. Its signal is related to flux, whereas a camera image of identical preparations at one time probes a position distribution. For a one-dimensional free wavefunction the continuity equation is \(\partial_t|\psi|^2+\partial_xj=0\) with \(j=(\hbar/m)\operatorname{Im}(\psi^*\partial_x\psi)\). Integrating over the region \(x<X\) gives the change in probability to the left of a fixed plane. If there is no flux at negative infinity, the net integrated current through \(X\) equals the reduction in that probability. A positive-reading counter with absorption is a more detailed instrument and cannot in general be identified with a signed current in the presence of reflected waves or interference.
For a minimum-uncertainty Gaussian initially at \(x_0\), the exact phase in the freely expanding envelope has a quadratic term. Differentiating the phase gives the local velocity entering current,
At the centre this equals the group velocity \(p_0/m\), but ahead of the centre it is larger and behind it smaller. A single constant velocity multiplying density is inadequate for a significantly spreading packet. For the earlier atom at \(t=t_s\), one current-standard-deviation distance ahead corresponds to \(1.41\,\mu\mathrm m\) and the additional speed is about \(0.259\) mm/s. The trailing side gives the opposite correction. Direct differentiation of its Gaussian density verifies that this current satisfies continuity. A code reproducing \(s_t\) but evolving the wrong complex phase may fail this current test; judging an entire propagation by the changing width alone would miss the error.
A useful inverse question is whether two time-of-flight images suffice to recover an unknown complex wavefunction. In the long-time limit the image yields \(|\phi(p)|^2\), which contains no direct momentum-dependent phase. Translation of the initial wave packet changes \(\phi(p)\) by a linear phase, leaving the momentum density unchanged. Complex conjugate or chirped preparations can also share particular intensity records. Additional calibrated evolution, known reference interference or structural assumptions can provide phase information. Even an exact free propagator only defines the forward map; its invertibility on complex amplitudes does not imply intensity-only data identify every possible input. The experiment must specify which class of preparations and which measurement settings render the desired parameters estimable.
Track a continuous superposition through focus
Change a position-momentum correlation and compare the full packet width with an initially unchirped packet. A narrow width at one time does not determine its subsequent spread.
Plan an FFT comparison using physical position and momentum resolution
A grid propagator can track the same packet analytically solved earlier, then carry over its verified conventions to less elementary potentials. A common trap is to regard the number of points \(N\) as a single accuracy parameter. Define a periodic interval of physical length \(L=N\Delta x\). Discrete Fourier modes have \(k_j=2\pi j/L\), with negative wave numbers represented by negative indices after reordering. Their spacing is \(\Delta k=2\pi/L\); the largest distinct magnitude is close to \(\pi/\Delta x\). A narrow structure in momentum requires large \(L\). A high carrier momentum requires small \(\Delta x\). These conditions can fail independently even when the norm stays exactly one.
If \(\psi_l=\psi(x_l)\) is a sampled wavefunction in inverse square-root metres and the forward transform sums without \(1/N\), the approximated continuum \(k\)-amplitude is
The phase includes the physical coordinate origin adopted for the grid. Parseval then gives
A library returning a unitary discrete transform instead assigns a factor \(1/\sqrt N\) to both directions; multiplying its output by \(\sqrt{\Delta x/\Delta k}\) converts sample units. Plotting a library output directly against physical momentum without these scale factors is especially misleading when comparing two meshes. Total discrete \(\ell^2\) norm and continuum probability density are different normalisations of the same samples.
For the atom of mass \(1.44\times10^{-25}\) kg, \(s=1.00\) μm and \(v_0=2.00\) mm/s,
A box 80 μm wide gives spacing \(0.0785\,\mu\mathrm m^{-1}\), about 6.4 modes per rms momentum width. With \(N=256\), grid spacing is 0.3125 μm and Nyquist wavenumber is \(10.05\,\mu\mathrm m^{-1}\), exceeding \(k_0+5\Delta k_{\rm rms}=5.23\,\mu\mathrm m^{-1}\). This comfortably samples the initial carrier distribution. It is still necessary to check that the envelope remains inside the periodic box at the desired final time.
At \(t=10\) ms the packet centre has moved 20 μm and \(s_t\simeq3.80\) μm. Starting at the centre of an interval spanning \(-40\) to \(40\) μm, its five-standard-deviation front approaches \(39\) μm and begins testing the boundary margin. At 20 ms the centre alone reaches the periodic boundary. A perfectly unitary calculation will show it reappearing on the opposite side. This is correct for a ring and incorrect for a free-space flight image. Enlarging \(N\) while keeping the same \(L\) improves the Nyquist limit but does nothing to postpone this crossing. An open-boundary absorber can delay reflected artefacts but attenuates norm; a lost norm in that model should be compared with counted escape rather than naively enforced to zero.
Infer displacement and speed from a wrapped packet without mistaking periodicity for reflection
A code on a periodic box of length 80 μm reports a sharp packet peak at \(+35\) μm in one frame and \(-36\) μm in the next frame 4.50 ms later. Find a consistent uniform drift and identify the ambiguity if no speed prior is available.
Derive and check the result
The smallest forward displacement is \(+9\) μm after adding one full box length to the second position. It corresponds to \(2.00\) mm/s and agrees with the earlier preparation. Direct subtraction without unwrapping would give \(-71\) μm, or \(-15.8\) mm/s, an apparent reversal. All displacements \(9+80n\) μm for integer \(n\) yield the same wrapped pair, so the frames alone cannot identify the number of turns. A momentum measurement or a bound on speed relative to frame spacing resolves the branch. For an extended packet crossing a seam, use a periodic circular moment such as \(\langle e^{2\pi i x/L}\rangle\) so an ordinary spatial mean does not spuriously jump toward the box centre. If that circular moment is nearly zero, even its angular centre is ill-defined and a full density comparison is preferable.
Tutorial · design a momentum measurement
Distinguish an unresolved line from a finite-width packet
A periodic calculation of length \(L=100\,\mu\mathrm m\) contains mode \(n\). A detector bins momentum in intervals \(1.0\times10^{-29}\,\mathrm{kg\,m/s}\). How many box-mode spacings fit into a bin? What changes if the box length doubles at fixed physical packet?
Work through the solution
Here \(\Delta p=h/L=6.626\times10^{-30}\,\mathrm{kg\,m/s}\), so the detector bin spans about 1.51 spacings. The precise number of grid points falling within a bin depends on its endpoints. Doubling \(L\) gives roughly 3.02 spacings per bin. Each corresponding coefficient squared decreases approximately in proportion to \(\Delta p\), while the number included increases. The total probability should approach a stable integral on a progressively finer grid. If a graph compares \(|c_n|^2\) across the boxes, divide by the corresponding \(\Delta p\) before calling the ordinate a continuum density.
Calculate a threshold energy interval without evaluating a delta at zero
A packet's momentum density is nearly constant \(w_0\) over \(-p_c<p<p_c\). Obtain the probability for \(0<E<E_c=p_c^2/(2m)\) by two different integrations. What changes when only positive-momentum particles reach the counter?
Work through the solution
Direct integration in momentum gives \(2p_c w_0\). In energy the two branches contribute \(2mw_0/\sqrt{2mE}\). Its integral gives \(4mw_0\sqrt{E_c}/\sqrt{2m}=2p_cw_0\) as required. A positive-direction selector halves this particular probability when applied to the original ensemble. If the entire subsequent experiment is renormalised to the selected particles, divide again by the total positive-momentum probability. Those two reported probabilities correspond to different conditioning and should be labelled explicitly.
Infer the packet width from two images
The model atom has an initial measured width 1.56 μm and a width 1.85 μm after 2.73 ms. Assume a time-independent Gaussian instrument response and a freely evolving unchirped minimum-uncertainty state. Infer \(s\) and \(d\), and identify an additional check.
Work through the solution
Subtract squared widths to remove the detector:
The observed difference is about \(0.99\,\mu{\rm m}^2\), giving \(s\simeq1.0\,\mu\mathrm m\) and \(d=\sqrt{s_{\rm obs}(0)^2-s^2}\simeq1.2\,\mu\mathrm m\), within rounding. A third flight time tests the predicted quadratic in \(t\). A term linear in time would point to a nonzero initial correlation or to measurement drift. Independent calibration of the point-spread function distinguishes those interpretations from a nonminimum momentum width.