Fundamentals / Physics / Electrodynamics / Electromechanics, optics and measurement

Coupled optical and mechanical resonances

A vibrating mirror can imprint its position on an optical field, while the stored light pushes back on the mirror. An apparent pair of peaks can indicate two hybrid modes, interference at a readout port or two unrelated resonances. Starting from energy in a moving cavity, derive the coupled response and learn which measurements establish a coupling strength and its uncertainty.

From a moving boundary to a force per photon

Take a nearly empty Fabry–Pérot cavity of optical length \(L\) with one moving end. A longitudinal resonance has \(\omega_c=m\pi c/L\) for integer \(m\), neglecting frequency-dependent mirror phase. For a small extension \(x\), \(\delta\omega_c=(\partial\omega_c/\partial x)x\) with signed slope \(G_x=-\omega_c/L\). At fixed photon number \(n\) the optical energy is \(n\hbar\omega_c(x)\). Its derivative gives the radiation-pressure force on the coordinate. For this mirror \(F=-n\hbar G_x>0\) pushes outward. The derivative must be at fixed photon number. Differentiating a driven steady-state photon number as though it were a closed-system energy would incorrectly include work exchanged with the pump.

For a 10 mm cavity resonant near 1064 nm the frequency slope magnitude in ordinary frequency is about 28.2 MHz per nanometre. A static shift of 10 pm therefore changes the optical resonance by approximately 282 kHz. One photon exerts a mean force \(\hbar\omega_c/L\simeq1.87\times10^{-17}\) N. An equivalent classical derivation counts a momentum change twice per normal reflection for each relevant round trip. The two descriptions yield the same mean force. The mirror displacement is the properly normalised mode coordinate; in a flexural device the optically sampled position and the total physical mass are generally different from centre-of-mass displacement and mass.

Introduce a single mechanical eigenmode with effective mass \(m_{\rm eff}\), angular frequency \(\Omega_m\) and displacement scale \(x_{\rm zpf}=\sqrt{\hbar/(2m_{\rm eff}\Omega_m)}\). The single-photon coupling magnitude is \(g_0=|G_x|x_{\rm zpf}\). This normalisation is convenient even when the observed vibrations are entirely classical. For \(m_{\rm eff}=10\) ng and \(\Omega_m/(2\pi)=1.0\) MHz, \(x_{\rm zpf}=9.16\times10^{-16}\) m and \(g_0/(2\pi)=25.8\) Hz for the stated optical geometry. The small displacement scale explains why a coherent pump is normally used to make the interaction measurable.

How a laser couples frequencies that are otherwise far apart

An optical carrier oscillates at hundreds of terahertz, whereas the mirror may vibrate at only megahertz. Direct comparison of these two bare frequencies would never suggest a resonant exchange. A strong coherent pump supplies a phase reference and converts a mechanical displacement into optical sidebands. Move into a frame rotating at the pump frequency and write the cavity amplitude as its large steady part plus a small perturbation. The leading frequency-shift interaction is proportional to photon number times displacement. Expanding the intensity around the large pump keeps terms linear in both the probe field and displacement. The resulting coupling is \(G=g_0\sqrt{n_c}\), where \(n_c\) is mean intracavity pump photon number.

Tune the pump about one mechanical frequency below the optical cavity resonance. In the resolved-sideband and weak-fluctuation limit a near-resonant process moves one excitation between the mechanical mode and an upper optical sideband. The rapidly rotating opposite-sideband terms average out. Now the two coupled frequencies are an optical sideband offset and the mechanical frequency, measured relative to a common rotating reference. The large carrier frequency has already been accounted for by the pump. The pump phase can be absorbed into the mode definitions, so \(G\) may be chosen positive for this isolated pair.

If instead the pump is placed near the upper sideband, the surviving interaction creates or annihilates excitations in pairs. The passive exchange equations below cease to apply and strong pumping can produce amplification or instability. A bare two-oscillator machine driven mechanically near a shared natural frequency often has analogous exchange equations without a carrier pump. Identical matrices can describe different energy supplies; identify the drive and rotating reference before assigning a literal photon-to-phonon energy conversion.

Derive complex poles and the effect of unequal damping

Let \(a,b\) be small energy-normalised optical and mechanical complex amplitudes. In a frame where the uncoupled optical sideband has zero frequency, let the mechanical detuning be \(\delta\). Let \(\kappa,\Gamma\) denote energy linewidths in angular frequency, so amplitude decay rates are half these values. With an optical probe \(s\) at offset \(\omega\), the linear system is

\[\begin{pmatrix}\kappa/2-i\omega&iG\\ iG&\Gamma/2-i(\omega-\delta)\end{pmatrix}\binom{a}{b}=\binom{s}{0}.\]

Zeros of the determinant give autonomous complex mode frequencies. In the lossless case the eigenvalues are \(\delta/2\pm\sqrt{G^2+(\delta/2)^2}\). Far off resonance each branch approaches a bare mode. At zero detuning the two eigenvectors have equal optical and mechanical weights and the splitting is \(2G\). The eigenvectors rotate continuously through the avoided crossing, an important discriminator from two uncoupled lines simply passing through one another.

At zero detuning with losses, completing the square in the determinant gives

\[\omega_\pm=-i(\kappa+\Gamma)/4\ \pm\sqrt{G^2-(\kappa-\Gamma)^2/16}.\]

The real parts separate once \(G>|\kappa-\Gamma|/4\). The shared imaginary part above that threshold corresponds to a hybrid energy linewidth \((\kappa+\Gamma)/2\). Resolving two intensity features on a given instrument is a stronger, readout-dependent condition. The dimensionless cooperativity \(C=4G^2/(\kappa\Gamma)\) is yet another measure, comparing interaction against the product of dissipation scales. A value greater than one does not automatically prove two resolved normal-mode poles in a device with very unequal linewidths.

Use frequency numbers divided by \(2\pi\) consistently from here for examples. With optical linewidth 240 kHz, mechanical linewidth 40 kHz and coupling 160 kHz, the real pole separation is

\[2\sqrt{160^2-50^2}=304\,\mathrm{kHz}.\]

Both hybrid energy linewidths are 140 kHz, and cooperativity is 10.7. If coupling falls to 45 kHz, cooperativity is still about 0.844 and no real zero-detuning pole separation appears. At 50 kHz the square root reaches zero. Near that threshold even a small linewidth or detuning calibration error has a large effect on a coupling estimate inferred from a single splitting.

Compute what an optical or mechanical receiver actually sees

Invert the matrix. With \(D=(\kappa/2-i\omega)[\Gamma/2-i(\omega-\delta)]+G^2\), the small amplitudes are \(a=s[\Gamma/2-i(\omega-\delta)]/D\) and \(b=-iGs/D\). The poles are shared. Their numerators are different, so the two channels can show different apparent maxima. A port in reflection also has a directly reflected field that interferes with the leaking intracavity amplitude. Its intensity can display a narrow dip or asymmetric feature without a matching resonance-height pattern inside the cavity. A legitimate forward model must describe the measured port.

The graph plots the internal squared amplitudes relative to the bare on-resonance optical probe energy. Set the mechanical detuning to zero and reduce the coupling through 50 kHz. Compare the optical dip with the predicted real pole separation. Then set a substantial positive detuning and follow the transfer of mechanical response onto one branch. As a control set the coupling exactly to zero. The optical curve recovers the bare cavity Lorentzian and the mechanical probe-induced response vanishes. A thermally excited mechanical background, absent from this driven calculation, could remain in a real detector.

At zero detuning and zero probe offset,

\[a/a_{\rm bare}=1/(1+C).\]

For the default parameters the internal optical probe intensity at the centre is only \(1/(1+10.67)^2=0.00735\) of the bare peak. This deep feature alone still does not establish the pole spacing. An incoherent background, a frequency-dependent detector transfer or coherent feedthrough can alter peak and dip positions. Fit complex quadratures across a detuning series when available, and verify bare linewidths by independent ringdown or far-detuned spectra.

Check how energy linewidth and amplitude ringdown are related for one isolated resonance

Watch energy exchange in time and identify the linewidth convention

In an ideal equal-linewidth system starting with optical perturbation \(a(0)=a_0\), \(b(0)=0\) at zero detuning, change to symmetric and antisymmetric modes. Recombination gives

\[a(t)=a_0e^{-\kappa t/2}\cos Gt,\]
\[b(t)=-ia_0e^{-\kappa t/2}\sin Gt.\]

Their normalised total energy decays as \(e^{-\kappa t}\), while energy moves back and forth between optical sideband and vibration. The first full transfer occurs at \(t=\pi/(2G)\) if the rotating-wave approximation holds. For \(G/(2\pi)=100\) kHz, this is 2.50 microseconds. With a shared energy linewidth of 20 kHz in ordinary frequency the surviving energy fraction then is

\[e^{-2\pi(20\,{\rm kHz})(2.50\,\mu{\rm s})}=0.730.\]

A gated excitation shorter than the exchange period but long enough to avoid unwanted modes can prepare an approximately optical initial perturbation. Independent detection of an optical revival and a delayed mechanical response tests coherent exchange more strongly than the presence of two peaks alone. Comparing times of maxima directly with one half the reciprocal measured optical linewidth misidentifies the exchange physics. Check the decay of the sum of appropriately calibrated energies and the relative phase of the exchange. Electrical or optical feedthrough can produce a prompt apparent response with no mechanical build-up.

Infer a coupling with propagated measurement errors

When the two hybrid pole frequencies have been obtained from a justified fit and zero bare detuning is established, the coupling follows from the measured real separation \(S\):

\[G=\sqrt{S^2/4+(\kappa-\Gamma)^2/16}.\]

All quantities here can be expressed in the same ordinary-frequency units. If \(S=300\pm8\) kHz, \(\kappa=240\pm10\) kHz and \(\Gamma=40\pm4\) kHz, the estimate is 158.1 kHz. Independent small errors give

\[\partial G/\partial S=S/(4G)=0.474,\]
\[\partial G/\partial\kappa=-\partial G/\partial\Gamma=(\kappa-\Gamma)/(16G)=0.0791.\]

Combining in quadrature gives about 3.9 kHz uncertainty. A common frequency calibration can correlate all three inputs, and a fitted detuning and splitting from one scan may also be correlated. Use their covariance rather than multiplying independent error bars blindly.

A second inference varies intracavity pump power. Since \(G^2=g_0^2 n_c\), plot the squared fitted coupling against independently calibrated \(n_c\). A nonzero intercept could indicate an additional direct coupling, baseline fitting bias or a mode incorrectly assigned at low power. The linewidths themselves can vary with pump power because of heating or backaction, so fit or measure them across the scan. Incident optical power is not identical to stored photon number; cavity coupling, detuning and loss determine their relation.

A measured frequency shift and linewidth change reveal optical feedback

The same instrument can be operated below the resolved splitting regime and read out a dispersive shift of the mechanical response. Algebraically eliminate the optical amplitude in the two-mode equations while driving the mechanical mode weakly. Its inverse susceptibility acquires a self-energy contribution proportional to the optical susceptibility. Let \(x\) be probe frequency measured from the bare optical sideband and use the same linewidth convention as above. In the mechanical denominator the additional term is

\[\Sigma(x)=\frac{G^2}{\kappa/2-ix}=\frac{G^2(\kappa/2+ix)}{(\kappa/2)^2+x^2}.\]

Its real part adds to the amplitude damping, while its imaginary part shifts the resonant condition. At very weak coupling one can evaluate it at the bare mechanical frequency \(x=\delta\), because variation across the narrow mechanical peak is small. Near an avoided crossing or when the mechanical peak samples a large change in optical susceptibility, solve the coupled poles directly; simply adding a linewidth and shift then neglects the very hybridisation being tested.

In ordinary-frequency units choose \(G=10\) kHz, optical linewidth 200 kHz, mechanical linewidth 2 kHz and detuning \(+100\) kHz. At that offset the optical amplitude half-width is 100 kHz, giving \(\operatorname{Re}\Sigma=0.50\) kHz and \(\operatorname{Im}\Sigma=0.50\) kHz. The full mechanical linewidth increases from 2.0 to approximately 3.0 kHz. Its centre moves upwards by about 0.50 kHz with the adopted matrix signs. Moving to minus 100 kHz reverses the shift and preserves the added damping in this symmetric model. At zero detuning the predicted shift vanishes but the added linewidth is largest.

A scan on both sides is more discriminating than measuring broadening alone. A background rise in mechanical temperature changes integrated thermal noise and may change intrinsic loss, but need not reproduce this odd shift and even broadening pattern. Measure intrinsic linewidth far from the optical response and subtract that baseline. An unknown constant frequency offset can be removed with the two symmetric detunings, but an optical power dependence of cavity frequency can move the actual symmetry centre. Monitor the optical resonance during the scan.

The effective susceptibility describes classical feedback through the delayed optical field. It does not by itself specify the final mechanical temperature. A bath occupation or noise spectrum is also required to convert a damping change into an energy distribution. A driven response peak that broadens and lowers in amplitude is evidence for a changed susceptibility; thermal cooling additionally requires a calibrated measurement of the fluctuating mechanical displacement and its optical transduction.

Tutorial · A high cooperativity without resolved modes

A device has ordinary optical linewidth 1.00 MHz, mechanical linewidth 1.0 kHz and pump-enhanced coupling 30 kHz. Calculate cooperativity, compare the coupling with the real-splitting threshold and estimate the relative intracavity probe intensity at the central frequency. What observation would distinguish a narrow interference window from two separated poles?

Evaluate the three criteria independently

In kHz units the cooperativity is

\[4(30)^2/(1000\cdot1)=3.6.\]

The real-splitting threshold is \(999/4=249.75\) kHz, far above the actual coupling. Yet the zero-detuning centre intensity is \(1/(1+3.6)^2=0.0473\) relative to the bare optical peak. A narrow, deep structured feature is possible with no separated real pole frequencies in this model. The linewidth contrast permits mechanical response to interfere strongly within a broad optical susceptibility.

Acquire both amplitude and phase while scanning the absolute mechanical detuning and compare a coupled complex-response model with independently measured bare parameters. A pair of well-resolved poles should trace two consistent trajectories in both observables and can generate underdamped exchange in the time domain. A single optical intensity scan containing two flanks around a dip is insufficient to make that inference.

Tutorial · Diagnose an erroneous estimate of the single-photon coupling

An independent linewidth analysis gives pump-enhanced couplings 80 and 160 kHz at photon numbers \(4.0\times10^6\) and \(1.6\times10^7\). Estimate \(g_0/(2\pi)\) and predict the coupling at \(9.0\times10^6\) photons. A calibration revision doubles all inferred photon numbers while leaving the measured spectra unchanged. Which conclusions move?

Use coherent amplitude scaling and separate calibration from spectroscopy

Divide the respective couplings in ordinary frequency by the square roots of their photon numbers. Both give 40 Hz and the intermediate prediction is 120 kHz. Doubling all inferred photon numbers lowers the inferred single-photon coupling by \(1/\sqrt2\), to 28.3 Hz. The observed enhanced couplings, pole locations and cooperativities computed from measured linewidths stay the same. A prediction labelled by fixed physical photon number changes; a prediction at a repeatable laser setting can still be calibrated empirically.

To test the absolute calibration, compare the inferred single-photon value with the independent cavity frequency slope times the mechanical zero-point displacement. This requires an effective mass appropriate to the measured displacement and the actual cavity optical overlap. An incorrect choice of mechanical mode normalisation can mimic an error in stored photon number. Agreement across a power ratio tests the square-root scaling but cannot by itself determine the absolute optical or mechanical calibration.

Aspelmeyer, Kippenberg and Marquardt · cavity optomechanics, linearisation and strong coupling