Fundamentals / Physics / Electrodynamics / Fields and the response of matter

How a magnetic field rotates the polarisation of transmitted light

Resolve a linearly polarised wave into circular eigenmodes, infer a refractive-index difference from an analyser and distinguish nonreciprocal rotation from a simple change of reference axes.

Derive rotation from propagation rather than drawing an arrow

Let monochromatic light propagate along \(+z\) through a transparent magneto-optic sample, with an externally prepared axial magnetic field. Define fixed laboratory vectors \(\mathbf e_\pm=(\hat x\pm i\hat y)/\sqrt2\) and use phasors \(e^{i(kz-\omega t)}\). These definitions specify the handedness algebraically. Calling a vector simply “right circular” without stating the viewing and time conventions can reverse a reported rotation sign.

An input linearly polarised in \(x\) is \((\mathbf e_++\mathbf e_-)/\sqrt2\). Suppose the medium supports wave numbers \(k_\pm=2\pi n_\pm/\lambda_0\) for the two bases, with negligible absorption. After a distance \(L\), factor out the common phase \(e^{i(k_++k_-)L/2}\). The remaining Cartesian phasor is \(\hat x\cos\Delta-\hat y\sin\Delta\), where \(\Delta=(k_+-k_-)L/2\). Thus the polarisation angle in the fixed \(x,y\) plane is

\[\theta=\frac{\pi L}{\lambda_0}(n_- - n_+).\]

Equal transmissions of the two components preserve a linearly polarised output. Unequal absorption makes the circular amplitudes unequal and generally produces an ellipse. Rotating a linear analyser then finds a finite minimum, even for a perfectly coherent field. Residual intensity at the nominal extinction angle can also arise from stray light or imperfect polariser extinction, which must be measured independently.

Derive a magneto-optic eigenbasis

For axial magnetisation, a simple lossless transverse relative-permittivity block is \(\left(\begin{smallmatrix}\epsilon&i g\\-i g&\epsilon\end{smallmatrix}\right)\) with real \(g\) at the frequency of observation. Acting on \((1,i)\) gives \((\epsilon-g)(1,i)\); acting on \((1,-i)\) gives \((\epsilon+g)(1,-i)\). For relative permeability near one, \(n_+^2=\epsilon-g\), \(n_-^2=\epsilon+g\). At small \(g\) their difference \(n_- - n_+\simeq g/\sqrt\epsilon\). Reversing magnetisation reverses the sign of the off-diagonal coefficient and interchanges the two eigenvalues. Both the existence of circular modes and the sign-reversal test now follow from a constitutive model.

If \(n_--n_+\) is proportional to magnetic field over a specified range, write \(\theta=VBL\), with Verdet constant \(V\) in rad/(T m). This is a measurable material and wavelength dependent coefficient. It is not determined by the mean refractive index alone. A strong nearby absorption line can give substantial frequency dependence and dichroism, invalidating a lossless narrow-band extrapolation.

Work through an analyser calibration

For \(\lambda_0=600\) nm, \(L=0.20\) mm and measured index difference \(5.0\times10^{-4}\), the rotation is \(\pi(2.0\times10^{-4})(5.0\times10^{-4})/(6.0\times10^{-7})=\pi/6\), or 30°. An ideal analyser at angle \(\alpha\) transmits \(I/I_\mathrm{in}=\cos^2(\alpha-\theta)\). Its maxima occur at \(30^\circ\) and \(210^\circ\); an intensity measurement determines a linear polarisation angle modulo 180°. For a sample thick enough to rotate several half turns, an intensity maximum alone cannot give an unwrapped \(\theta\). Vary field or path length continuously from a known reference.

If the applied field is independently 0.40 T in that example, \(V=\theta/(BL)\simeq6.54\times10^3\) rad/(T m). The arithmetic is dimensionally correct, but the large value warrants a physical check of thickness, field calibration, units and material spectrum before reporting it as an ordinary glass coefficient. Degrees substituted for radians would make the inferred material coefficient too large by \(180/\pi\).

Use field reversal to reject alignment errors

The experiment shows the predicted analyser traces for opposite index splitting, with the same input polariser. Increase sample thickness to see why tracking the maximum by one measurement can select the wrong branch. Reversing the splitting reverses the tilt in fixed laboratory axes. A fixed analyser offset shifts both inferred angles equally and cancels in half their difference, provided the branch has been unwrapped consistently.

For small rotation, an analyser exactly at a crossed position transmits intensity proportional to \(\theta^2\). Its response has no sign sensitivity close to zero. Set the analyser at 45° instead:

\[\cos^2(\pi/4-\theta)=[1+\sin(2\theta)]/2\simeq1/2+\theta.\]

The difference between fields \(+B\) and \(-B\) then measures a signed signal linear in small rotation. This trades extinction of the background for sensitivity to sign. Balance the two orthogonal analyser outputs if source intensity fluctuates appreciably during a sweep.

Ask what happens on a return pass

For the ideal Faraday medium at fixed magnetisation, the circular eigenmodes relative to a fixed laboratory basis are determined by its transverse material tensor. On propagation back through the sample, the accumulated positive propagation path again distinguishes the same laboratory circular basis after accounting for the reflection boundary. With a suitable simple mirror at normal incidence, the resulting material rotation doubles on a round trip in fixed transverse coordinates. In a reciprocal optically active material, the eigenvalue assignment with respect to the laboratory basis reverses on reversing propagation, and the single-pass rotation cancels on the ideal return. Write both transformations in one fixed basis before comparing signs.

A real double-pass setup includes mirror phase shifts, stress birefringence of windows and possible ellipticity. Reversing magnetic field, removing the sample and recording both analyser quadratures provide separate checks. A nonzero rotation in one transmitted beam proves only that its polarisation changed; establishing nonreciprocity requires comparing a reversed propagation experiment with a stated polarisation convention.

Tutorial

Two analyser maxima occur at 47° and 39° for opposite weak fields. If the response is linear and the same branch is tracked, what field-induced rotation and static offset do they imply?

Work through the solution

Half the difference gives 4 degrees of signed rotation for the first field relative to zero. The mean is 43 degrees, the combined input polarisation and analyser zero. Conversion to a Verdet constant additionally needs the applied field and path length.

In the 600 nm example, what thickness uncertainty corresponds to 1 degree of rotation uncertainty at fixed index difference?

Work through the solution

Rotation is proportional to thickness. Relative uncertainty \(1/30\) therefore gives about \(0.20/30=0.0067\) mm, or 6.7 μm. Uncertainty in wavelength or field would add additional contributions.

An ideal analyser gives a minimum 4% of its maximum. Can this be explained solely by a rotation of an ideal linearly polarised monochromatic input in a lossless circularly birefringent sample?

Work through the solution

Pure rotation preserves a linear state, so an ideal analyser should extinguish it completely. Differential loss, ellipticity, depolarisation, finite bandwidth or a detector background are possible alternatives. Use circular-analysis or full Stokes measurements and an empty-path baseline to distinguish them.

Compare with a full polarisation measurement

Use the Stokes reconstruction experiment to determine which intensities reveal a circular component. A fitted linear rotation alone cannot measure that missing component.