Fundamentals / Physics / Electrodynamics / Waves, radiation and relativity

Diffraction from the near field to the focal plane

An illuminated aperture is a boundary condition for a wave. A screen a millimetre away, an intensity camera at a lens focus and a microscope measuring an evanescent field sample different consequences of the same condition. We will derive operators for propagating the field, estimate the approximations each instrument makes and use energy and sampling checks to tell numerical structure from a measurable fringe.

How each spatial frequency propagates

Take a monochromatic scalar field with physical value given by the real part of \(U(x,y,z)e^{-i\omega t}\). This approximates one transverse component when the polarisation remains nearly uniform and angles are small. In a homogeneous transparent half-space it obeys the Helmholtz equation. Specify the complex amplitude in the plane \(z=0\) and require outgoing or decaying waves for positive \(z\). Fourier transform the two transverse coordinates, leaving a differential equation in the third.

\[\partial_z^2\widehat U+(k^2-k_x^2-k_y^2)\widehat U=0,\]
\[\widehat U(k_x,k_y,z)=\widehat U(k_x,k_y,0)e^{ik_z z},\]
\[k_z=\sqrt{k^2-k_x^2-k_y^2}.\]

Choose the root with positive real part for propagation and positive imaginary part for decay. Each propagating component advances in phase. Hence power integrated over a plane is unchanged for a paraxial beam with no absorbing aperture downstream. For angles approaching grazing incidence the weight for normal flux contains the direction cosine. Components with transverse wavenumber exceeding \(k\) decay exponentially. An aperture map thus contains structures invisible to a distant measurement even if the map itself is known exactly.

In vacuum a sinusoidal field structure of period 400 nm illuminated at 600 nm has \(k_x/k=1.50\). Its amplitude has fallen to \(1/e\) after \(1/(k\sqrt{1.5^2-1})=85.4\) nm. At 500 nm the remaining amplitude is 0.00287 and the squared amplitude is roughly eight parts in a million of its plane value. A numerical back-propagation that reinstates the original component also multiplies measurement errors by about 350. Improving detector gain does not restore the unknown phase.

A propagation kernel with a controlled phase error

For small transverse wavenumber, expand \(k_z=k-k_\perp^2/(2k)-k_\perp^4/(8k^3)+\cdots\). The first correction becomes a chirp in Fourier space. Completing the square in its inverse transform gives the Fresnel kernel. Write \(\mathbf r\) for a transverse observation point and \(\boldsymbol\xi\) for a point in the aperture.

\[U(\mathbf r,z)\simeq\frac{e^{ikz}}{i\lambda z}\int U(\boldsymbol\xi,0)\exp\!\left[\frac{ik}{2z}|\mathbf r-\boldsymbol\xi|^2\right]d^2\xi .\]

This expression retains phase curvature across the aperture. The coefficient ensures that a spatially uniform boundary amplitude reproduces a uniform plane wave. An uncovered infinite plane is a useful test for a numerical convolution, although a finite computation needs padding or a truly periodic uniform test. A measured slit has sharp edges with broad spatial spectra, so peak error near an edge can exceed the error suggested by a small angle evaluated for the central lobe.

At an observation angle \(\theta\) a propagation distance \(z\) accumulates neglected phase of order \(kz\sin^4\theta/8\). For \(z=0.10\) m, \(\lambda=500\) nm and \(\theta=0.01\) rad this is 0.00157 rad. At 0.05 rad it is close to one radian. A faint sidelobe at a moderately large angle can require exact angular-spectrum propagation even while a paraxial estimate describes the central spot beautifully.

Which quadratic term can the far field lose?

Expand the kernel's square into an observation phase, a source phase and a bilinear term. Only the source phase can be dropped without changing the predicted intensity directly through that factor. For source radius \(a\) its maximum value is \(\pi a^2/(\lambda z)\). The remaining integral is the Fourier transform of the aperture at spatial frequencies \(x/(\lambda z),y/(\lambda z)\). Define the Fresnel number using the half-width \(a\). A convention based on full slit width gives a value four times larger.

\[U(\mathbf r,z)\simeq\frac{e^{ikz+ikr^2/(2z)}}{i\lambda z}\,\widehat U\!\left(\frac{kx}{z},\frac{ky}{z},0\right),\]
\[N_F=\frac{a^2}{\lambda z}.\]

For a uniformly illuminated slit of full width \(w=0.20\) mm at 532 nm and \(z=1.0\) m, \(N_F=0.0188\). Direct integration of the linear aperture phase gives

\[I/I_0=\mathrm{sinc}^2(\pi wx/\lambda z),\]

where \(\mathrm{sinc}(u)=\sin(u)/u\). The first zeros should be 2.66 mm either side of centre. The edge phase is 0.059 rad. Moving the screen to 30 mm gives \(N_F=0.627\) and edge phase 1.97 rad. Substituting the smaller distance in the far-field formula yields a number but no longer a controlled approximation.

Compare near- and far-field predictions in the slit integral

In that experiment reduce the mesh interval before moving the screen. If the exposed variable counts panels, doubling panels at fixed aperture halves the interval. A converged difference between the full and far-field integrals is a physical failure of the approximation. A feature that moves each time the number of source samples doubles is a numerical failure. Keep the same physical horizontal axis and the same normalisation when comparing adjacent screens.

From a circular pupil to a resolution measurement

When the pupil is a disk, polar coordinates considerably simplify the Fourier integral. Align the transverse transform vector along the horizontal axis. The angular average of \(e^{-iqr\cos\phi}\) defines \(J_0(qr)\). One radial integration, using \(d[uJ_1(u)]/du=uJ_0(u)\), then gives the result. Divide by the on-axis amplitude, proportional to aperture area.

\[\frac{U(q)}{U(0)}=\frac{2}{a^2}\int_0^a rJ_0(qr)\,dr=\frac{2J_1(qa)}{qa},\]
\[q=k\sin\theta .\]

At \(qa=0\) use \(J_1(s)\sim s/2\). The first zero is at \(qa=3.8317\). Hence a disk of diameter \(D\) has its first dark ring at \(\sin\theta=1.22\lambda/D\). Two mutually incoherent identical points contribute the sum of their intensities. Rayleigh's conventional separation places each peak on the first zero of its neighbour. A coherent pair instead has an interference term that depends on the unknown relative phase. The same separation criterion cannot predict its measured trough without that phase.

A 5.0 mm pupil on a 100 mm focal-length lens at 550 nm gives a first-zero radius of 13.4 micrometres on the focal plane. A camera with 6.5 micrometre pixels spans the full bright core with about four pixels. Fitting the central pixel alone to find the image position would depend strongly on whether the spot lay on a pixel centre or a corner. A joint fit to integrated pixel intensities can estimate a position more precisely than the image width when enough photons are detected. That precision describes one isolated spot and does not directly give a two-source resolution.

Why a lens puts the spectrum close at hand

A thin positive lens adds the quadratic phase \(-kr^2/(2f)\) to a field immediately in front of it. At the plane \(z=f\), this cancels the source term of the Fresnel kernel exactly within paraxial theory. The focal intensity therefore samples a Fourier spectrum even for a tabletop lens standing much nearer than the free-space far-field distance. The physical exit pupil remains part of the amplitude. Closing it removes high transverse spatial frequencies in an imaging arrangement and broadens the spot of a point emitter.

For illumination with Gaussian amplitude \(U\propto e^{-r^2/w^2}\), completing the transverse Fourier integrals gives another Gaussian, with focal-plane amplitude radius \(w_0=\lambda f/(\pi w)\) for a broad lens and an incident flat wavefront. If \(w=1.0\) mm, \(f=100\) mm and \(\lambda=633\) nm, \(w_0=20.1\) micrometres. This is the \(1/e\) field radius, also the \(1/e^2\) intensity radius. The Rayleigh length \(\pi w_0^2/\lambda\) is 2.02 mm. Moving a detector one Rayleigh length off the waist increases the radius by \(\sqrt2\) and halves its on-axis intensity for fixed total beam power.

Use the ray-bundle experiment to locate the geometric focus before estimating its diffractive width

From a point image to transmitted object contrast

A microscope may resolve individual test objects yet deliver very little contrast for a periodic specimen at a similar length scale. The reason is that incoherent imaging acts linearly on intensity, while coherent imaging acts linearly on field amplitude. Start with mutually incoherent object points. Their expected image intensities add, so the image is the convolution of object intensity with a nonnegative intensity point-spread function \(h=|h_A|^2\), where \(h_A\) is the coherent amplitude impulse response. The Fourier transform of \(h\), normalised to one at zero spatial frequency, is the optical transfer function. Its magnitude describes attenuation of a sinusoidal intensity modulation.

For a focused unaberrated system the coherent amplitude response in Fourier space is the pupil function. The convolution theorem applied to \(|h_A|^2\) shows that the incoherent transfer function is the pupil autocorrelation. For a clear circular pupil this amounts to asking how much two equal disks overlap as their centres separate. The overlap consists of two circular sectors minus their triangular parts. With normalised frequency \(s=f/f_c\) and incoherent cutoff \(f_c=2\,\mathrm{NA}/\lambda_0\) in object space, the result is

\[M(s)=\frac2\pi[\arccos s-s\sqrt{1-s^2}],\quad 0\le s\le1,\]
\[M(s)=0\quad(s>1).\]

Here \(\lambda_0\) is vacuum wavelength and \(\mathrm{NA}=n\sin\theta_{\max}\). At \(s=0\) the disks coincide and the full mean intensity passes. At the cutoff their edges just touch and sinusoidal contrast vanishes. The coherent pupil transmits field spatial frequencies only through \(\mathrm{NA}/\lambda_0\). These two cutoffs answer different questions about different object and illumination statistics. A coherent phase grating viewed in exact focus can yield an almost uniform intensity image despite transmitting several field components.

For \(\mathrm{NA}=0.25\) at 550 nm, the incoherent cutoff is 909 cycles/mm. A sinusoidal target of 450 cycles/mm has \(s=0.495\) and \(M\simeq0.396\). An object with 0.60 sinusoidal intensity visibility is predicted to show about 0.238 before detector averaging. If the object-referred pixel width is 0.75 micrometres, rectangular pixel integration multiplies this contrast by \(\mathrm{sinc}(\pi fp)=0.823\); the recorded visibility is about 0.196. Nyquist frequency for this pixel spacing is 667 cycles/mm. Hence even some frequencies that the optics can transmit lie above the detector Nyquist limit and can alias back to lower apparent frequencies.

This prediction can be tested with an adjustable magnification while keeping entrance pupil and object fixed. Object-referred pixel width falls as magnification rises; a pixel-limited measurement should approach the optical transfer curve. Raising magnification also spreads light over more pixels, changing per-pixel count noise, so compare fitted contrasts with uncertainty. At frequencies where the ideal transfer is small, a high-contrast target and low read noise matter. Dividing by an arbitrarily small transfer function to sharpen the final image can turn noise into a convincing periodic pattern.

A pupil-phase error redistributes energy without absorbing it

Introduce a known defocus into a clear circular pupil. Let the phase relative to its centre vary as \(\phi(r)=\Phi r^2/a^2\). The on-axis focal amplitude is proportional to the pupil average of \(e^{i\phi}\), since all ideal contributions arrive in phase there. Integrate in polar coordinates and substitute \(u=r^2/a^2\). Relative to the perfect on-axis intensity the result is

\[S=\left|\int_0^1e^{i\Phi u}du\right|^2=\left[\frac{\sin(\Phi/2)}{\Phi/2}\right]^2 .\]

This special-case Strehl ratio assumes a uniform pupil and pure quadratic defocus. Removing a phase piston makes no change to intensity. Expanding for small \(\Phi\) yields

\[S=1-\Phi^2/12+\cdots.\]

The pupil-phase variance after removing the mean piston is \(\Phi^2/12\), which explains the leading connection between reduced peak intensity and wavefront variance without assuming that every type of aberration has the same pattern.

A quarter of a wave of centre-to-edge optical path error gives \(\Phi=\pi/2\) and \(S=0.811\). One half wave gives 0.405. In an ideal phase-only pupil the missing on-axis intensity appears elsewhere in the image; total transmitted power over a sufficiently wide observation plane is unchanged. Contrast this with an absorbing pupil that removes a uniform fraction of intensity everywhere. Measuring only the brightest pixel confuses the two. Measure integrated power over increasing radii and fit a spatial profile as well as a peak.

To turn this into an axial calibration, derive the edge phase from the distance mismatch. For a paraxial marginal ray in air making angle approximately \(\mathrm{NA}\), an axial shift \(\Delta z\) introduces a relative phase magnitude near \(k\,|\Delta z|\,\mathrm{NA}^2/2\). At \(\mathrm{NA}=0.10\), \(\lambda=500\) nm and \(|\Delta z|=25\) micrometres this is 1.57 rad, the quarter-wave case. With a larger numerical aperture use actual longitudinal wavevectors instead of the quadratic approximation and model polarisation where required. The formulas predict the same on-axis drop for positive and negative defocus. A single peak reading cannot give the sign of an axial misplacement; scanning through focus supplies that missing sign and can reveal an asymmetric aberration.

Distinguish aperture physics from quadrature error

Refine the aperture samples and vary their physical extent independently. A moving numerical null and a true diffraction minimum have different refinement signatures.

Worked optical problem · determine how much light fits into one Airy disk

Two groups compare image quality using respectively the peak intensity and the energy contained inside the first dark ring. Derive the encircled-energy fraction for a uniform circular pupil and obtain its value at the first ring. Would closing the aperture increase the useful energy fraction on a detector of fixed physical radius?

Integrate the radial intensity with its area measure

Write \(v=ka\sin\theta\), and use the small-angle focal-plane variable proportional to image radius. Focal intensity varies as \([2J_1(v)/v]^2\). The annular area element supplies a factor \(v\,dv\). Use \(J'_0=-J_1\) and \(J'_1=J_0-J_1/v\) to differentiate \(J_0^2+J_1^2\). The derivative is \(-2J_1^2/v\), giving the fraction inside radius \(v\) as \(1-J_0(v)^2-J_1(v)^2\). It tends to zero at the origin and to one at very large radius, which fixes the integration constants and normalisation without needing an absolute incident amplitude.

At \(v=3.8317\), \(J_1=0\) and \(J_0\simeq-0.4028\). The encircled fraction is therefore 0.838. The remaining 16.2 percent is outside the central disk even in a perfect ideal image. If the physical detector radius corresponded to this value before closing the pupil, reducing the pupil radius decreases \(v\) at the detector edge and therefore decreases the collected fraction. It also ordinarily reduces the total incident power transmitted by the pupil.

Peak-normalised plots rescale each pupil's image to one at its centre, which hides both effects. For a fair power comparison record the total incident flux, the pupil transmission and the energy on the fixed detector. A phase aberration or obscuration can leave the nominal first-zero position a poor boundary for comparing different pupils. The same physical encircled radius offers a reproducible metric in those cases, provided the beam centre and background are estimated independently.

A phase ramp moves a diffraction pattern without changing its shape

Illuminate a thin aperture with a tilted plane wave in the paraxial regime. At the aperture plane this multiplies its complex amplitude by a linear phase ramp. The Fourier shift theorem then moves the entire focal-plane amplitude by a transverse amount \(f\sin\theta_i\) along the tilt direction. Its intensity pattern retains its shape as long as the illumination envelope fills the pupil uniformly and the lens has enough acceptance. Tilting a narrow 532 nm beam by one milliradian in front of a 100 mm lens moves the pattern by about one tenth of a millimetre.

This provides a practical separation of phase tilt from aperture narrowing. A tilt moves both first zeros in the same direction, whereas changing the width of a centred slit moves the zeros apart or together. A position fit using one zero alone cannot separate these perturbations. Jointly fitting both zeros yields a mean position sensitive to tilt and a separation sensitive to width. A scanned detector with unequal position calibration on the two sides can mix the two observables.

For a spatially incoherent angular source, integrate intensities of the shifted patterns over the angular source distribution. An extended source then blurs zeros that would be sharp under one coherent angle. A coherent superposition of the same angular components instead requires adding the shifted amplitudes and can produce additional fringes. The illumination statistics determine which calculation describes the recorded image.

Tutorial · Distinguish a pupil defect from pixel integration

In a slit focal pattern the central lobe has one-sided first-zero distance 40 micrometres. An analyst samples precisely at that first zero using a centred pixel 8 micrometres wide and finds positive intensity. Estimate the finite-pixel fraction and propose a measurement that would expose an additional scattered background.

Show the pixel calculation and a discriminating test

Let \(x=x_0+s\), where \(|s|\) is much smaller than \(x_0\). The sinc amplitude near its zero is approximately \(-s/x_0\), giving intensity \(I/I_\mathrm{peak}\simeq s^2/x_0^2\). Averaging across a pixel of width \(p\) gives \(p^2/(12x_0^2)\), about \(3.33\times10^{-3}\). This estimate uses a flat response within each pixel and a sample centred on the true minimum. A two-micrometre centring error contributes about another 0.0025 at leading order.

Use magnification that doubles the first-zero distance in pixel units while keeping pupil and wavelength fixed. Pixel leakage at a centred zero should then fall by four relative to the peak. A background proportional to local scattered light may respond differently and a dark offset can be estimated from opaque-frame counts. Calibrate differing exposure and throughput, subtract dark counts prior to normalisation and fit both flanks to locate the true minimum.

Tutorial · Design a propagation-grid check

A 512-point transverse grid with 2 micrometre spacing represents an aperture at 600 nm. What angle can the grid represent? Could its periodically repeated boundary contaminate a nominal 0.08 rad bundle after 10 mm propagation, if the beam spreads from the centre? Explain two refinements that test distinct errors.

Show the angular and spatial budgets

Nyquist gives \(|k_x|\leq\pi/\Delta x\), hence

\[|\sin\theta|\leq\lambda/(2\Delta x)=0.15.\]

The 0.08 rad direction is resolved in principle, although modes near Nyquist would need a separate resolution study. Its lateral displacement over 10 mm is about 0.802 mm, larger than the 0.512 mm half-window even for a beam initially confined to its centre. A periodic FFT can therefore wrap light around into the opposite side.

Double the number of points with spacing fixed. This doubles the window while keeping the represented angular limit fixed. Then halve the spacing while doubling the number again to leave this enlarged window fixed and test transverse discretisation independently. Compare conserved flux, central intensity and the location of the first minimum, retaining absolute normalisation. Flux conservation in a periodic window can hold perfectly even when light has wrapped across its boundary. A plot of that single diagnostic would miss the contamination.

MIT 2.71 Optics · Fourier optics, apertures and propagation