Choose a branch that decays into the material
Let a stationary plane wave enter the homogeneous half-space \(z>0\) at normal incidence. Use \(e^{-i\omega t}\) and fields proportional to \(e^{ikz}\), real \(\epsilon,\mu>0\) and Ohmic \(\mathbf J=\sigma\mathbf E\), \(\sigma\geq0\). Ampère's law combines the two currents into \(-i\omega(\epsilon+i\sigma/\omega)\mathbf E\). Faraday's law yields
Eliminating \(H\) gives
Choose \(\beta>0,\alpha\geq0\) so the interior field weakens with depth. Let \(k_d=\omega\sqrt{\mu\epsilon}\). Equating real and imaginary parts gives \(\beta^2-\alpha^2=k_d^2\), \(2\beta\alpha=k_d^2 t\), and hence
The rational expression for \(\alpha\) avoids subtracting nearly equal numbers for small \(t\). As \(t\to0\),
For \(t\gg1\), \(\beta\simeq\alpha\simeq\sqrt{\omega\mu\sigma/2}\): skin depth \(1/\alpha\) measures field-amplitude decay and the power has the shorter e-folding depth \(1/(2\alpha)\).
Read the complex reflection and the power entering the surface
Let the incident medium be lossless with impedance \(Z_1\). Continuity of tangential \(E,H\) gives
where \(h=E(0^+)/E_{\rm inc}\). Solving,
The flux relation follows by dividing the real part of \(E H^*/2\) by the incident intensity. It includes a real admittance and is generally different from \(|h|^2\). The imaginary part of the complex Poynting vector measures exchange in quadrature with the drive. In the good-conductor limit \(Z\simeq(1-i)\sqrt{\omega\mu/(2\sigma)}\). Its positive real part is essential for passive heating, even where the reflected voltage is almost the negative of the incident one.
Recover the entire inward power from a volume measurement
Ohmic heating per volume is \(\langle p_J\rangle=\sigma|E(0)|^2 e^{-2\alpha z}/2\). Integrating from zero to infinity gives
Use \(2\beta\alpha=\mu\omega\sigma\) to rewrite it as \(|E(0)|^2\beta/(2\omega\mu)\). This equals the inward mean surface flux from \(E H^*/2\). No separate efficiency factor is needed. The fraction of surface power dissipated before depth \(D\) is \(1-e^{-2\alpha D}\), so 90% of the heat is deposited by \(D=\ln10/(2\alpha)\), about 1.15 field skin depths.
Compare two frequency regimes
A crossover with comparable currents
Consider material whose lossless impedance equals the incident medium’s and whose loss ratio is \(t=2\). Then \(\beta/k_d=1.272\), \(\alpha/k_d=0.786\), and \(Z/Z_1=0.569-0.352i\). Direct complex division gives a reflected power fraction of about 0.120. The balance enters the half-space and ultimately heats it. One lossless phase length \(k_d^{-1}\) into the material, the remaining forward power is \(e^{-1.572}=0.208\) of its surface value. This illustrates substantial heating even though most incident power enters the material.
An amplitude probe and a calorimeter
Suppose a field-amplitude probe reads 1/e of its surface value at depth 0.80 mm. Then \(\alpha=1250\) m⁻¹, the power half-depth is \(\ln2/(2\alpha)=0.277\) mm and 90% of the absorbed energy is deposited by 0.921 mm. These predictions do not require knowing the incident intensity. Disagreement between the two types of measurement can reveal spatially varying \(\sigma\) or a reflected wave from a finite back surface.
Close a reflection and heating budget at every depth
At loss ratio 2 and matched lossless impedances, about 12% of the incident power is reflected. The remaining power gradually becomes heat. Change loss and impedance independently and check that the surface reflection, transmitted flux at depth and integrated heat always add to one.
Problem sheet · determine a material from two probes
Recover material parameters
At frequency \(f\) in a nonmagnetic half-space, phase measurements give \(\beta\) and amplitude measurements give \(\alpha\). Recover \(\sigma,\epsilon\), and specify the consistency condition for the dielectric model used here.
Work through the solution
Solve for \(\sigma=2\beta\alpha/(\mu_0\omega)\) and \(\epsilon=(\beta^2-\alpha^2)/(\mu_0\omega^2)\). A medium with positive real permittivity in this simple Ohmic model requires \(\beta>\alpha\). In the good-conductor limit their difference is small, making the inferred permittivity sensitive to measurement errors.
When does an infinite depth assumption fail?
For a slab of thickness \(D\), the back-face field reflection magnitude is 0.50. Bound the return amplitude at the entrance relative to the forward wave inside, ignoring subsequent round trips. How thick keeps it below 1%?
Work through the solution
The round trip attenuates the field by \(e^{-2\alpha D}\). Require \(0.50e^{-2\alpha D}<0.01\), giving \(D>\ln50/(2\alpha)=1.96/\alpha\). Phase may suppress the measured amplitude at selected frequencies, but the magnitude bound does not depend on that cancellation.
Further reading
Study the full derivation
Causal material response and the propagation of a finite pulse · Waves, radiation and relativity
An optical pulse entering a transparent slab is delayed, broadened and sometimes reshaped. Derive these effects from the motion of bound charge, and learn what a measured group delay actually says about a pulse carrying information.