Magnetic and electrical material measurements
Follow a microscopic carrier or bound current into a measured Hall voltage, external field, magnetic response or penetration depth.
- From microscopic moments to measured magnetisation
- Interfaces, demagnetising fields and the work of magnetisation
- Measure how quickly a dielectric follows an electric field
- Identify mobile charge with a transverse field
- When does a polar crystal change its preferred state?
- Distinguish magnetic screening from electrical diffusion
- Why rotating a layered dielectric changes a capacitance measurement
- How a magnetic field rotates the polarisation of transmitted light
- Adding angular momentum and predicting which lines can appear
- When a magnetic field changes the quantum numbers of an atom
From microscopic moments to measured magnetisation
Magnetism, induction and field dynamics
A magnetised sample can make a compass turn without a power supply attached. The macroscopic theory assigns it bound currents in its bulk and on its surface. These are calculated sources for the magnetic field. We will reconstruct them from magnetic moments, predict signals from finite samples, and ask what an exterior field measurement can identify.
Define a material field at an intermediate scale
Choose a volume large enough to average over microscopic moments and small enough to resolve the sample's macroscopic variation. Let \(\boldsymbol M(\boldsymbol r)\) be the vector sum of moments within it divided by its volume. Its units are \(\mathrm{A/m}\). A permanent aligned collection may maintain \(\boldsymbol M\) without an applied field. An induced collection may point with or against the applied field. Electric charges need not traverse the entire sample in a closed macroscopic wire for either mechanism. Electron orbital moments and spin contribute to the measured moment; for a classical exterior field calculation any small magnetic dipole has the same leading field once its moment is specified.
A bar of volume \(8.0\,\mathrm{cm^3}\) with uniform \(M=2.0\times10^4\,\mathrm{A/m}\) has total moment \(m=0.160\,\mathrm{A\,m^2}\). A torsion balance in a uniform \(10\,\mathrm{mT}\) transverse field would measure a maximum torque \(1.60\times10^{-3}\,\mathrm{N\,m}\) if its moment stayed fixed. Dividing a measured torque by field and sample volume infers the component normal to the external field. Alignment of a previously soft material could instead alter the very moment being measured. Distinguishing fixed-source and induced-response experiments will matter when we calculate mechanical energy.
Derive the bound sources by integration by parts
Sum the dipole vector potentials over a material region \(V\). With observation point outside the matter, a volume element contributes \((\mu_0/4\pi)\boldsymbol M(\boldsymbol r')\times(\boldsymbol r-\boldsymbol r')dV'/R^3\), where \(R=|\boldsymbol r-\boldsymbol r'|\). Note that \(\nabla'(1/R)=(\boldsymbol r-\boldsymbol r')/R^3\). Apply the identity \(\nabla'\times(\boldsymbol M/R)=(\nabla'1/R)\times\boldsymbol M+(\nabla'\times\boldsymbol M)/R\). The desired first cross product is minus the first term on the right. A volume integral of a curl is the surface integral of outward normal crossed with the vector. This yields
Comparing with the ordinary current potential identifies \(\boldsymbol J_b=\nabla\times\boldsymbol M\), in A/m², and \(\boldsymbol K_b=\boldsymbol M\times\boldsymbol n\), in A/m. The first can vanish throughout a uniformly magnetised object, while the second closes around its exterior. A literal set of microscopic loops illustrates the sign. Neighbouring loop-edge currents cancel between equal adjacent moments, whereas their edges on the outer boundary remain uncompensated. When the moments vary slowly, interior cancellation is incomplete and yields the curl.
An alternative treatment extends \(\boldsymbol M\) by zero outside. Its distributional curl already includes the surface sheet at the discontinuity. Use either this full derivative or the separate bulk and surface integrals; including both descriptions simultaneously doubles the boundary source. At an internal interface with chosen normal from material 1 to 2 the two surface contributions combine to \((\boldsymbol M_1-\boldsymbol M_2)\times\boldsymbol n\). This expression is unchanged by interchange of the two labels accompanied by reversal of the normal.
Work through a uniformly magnetised cylinder
Let a finite circular cylinder of radius \(a\) and length \(2l\) have \(\boldsymbol M=M\hat{\boldsymbol z}\). On the curved side \(\hat{\boldsymbol z}\times\hat{\boldsymbol s}=\hat{\boldsymbol\varphi}\), hence \(K_\varphi=M\); on its end faces the cross product vanishes. The cylinder is equivalent, for its magnetic field, to a finite solenoid having turn-current per unit length \(M\). A strip of sidewall of height \(dz'\) carries ring current \(M\,dz'\). Insert this into the axial finite-loop field from the first chapter and integrate from \(-l\) to \(l\).
At the centre \(B_z=\mu_0M l/\sqrt{a^2+l^2}\). For \(a=10\,\mathrm{mm}, l=20\,\mathrm{mm}\) and \(M=1.0\times10^4\,\mathrm{A/m}\), the value is \(11.24\,\mathrm{mT}\), below the long-cylinder limit \(12.57\,\mathrm{mT}\). At the end centre \(z=l\), only the first term contributes, giving \(6.10\,\mathrm{mT}\). A probe just outside the end and one just inside see the same normal \(\boldsymbol B\) in the limit, even though the auxiliary normal \(\boldsymbol H\) can jump because \(\boldsymbol M\) ends abruptly. The field near an edge is not uniform and can vary strongly with the sensor's position. Stating the axis and position is therefore essential when inferring magnetisation from a reading.
Use a nonuniform sample to separate bulk and surface effects
For an infinitely long cylinder set \(\boldsymbol M=M_0(s/a)\hat{\boldsymbol\varphi}\) for \(s<a\), zero outside. The cylindrical curl gives \(J_{b,z}=s^{-1}\partial_s(sM_\varphi)=2M_0/a\) in the bulk. The side normal is \(\hat{\boldsymbol s}\), so \(K_{b,z}=-M_0\). Integrated over a cross section the bulk current is \(2\pi aM_0\); the axial sheet supplies \(-2\pi aM_0\). Their cancellation means an exterior Amperian circle sees zero enclosed current. Its zero field follows from symmetry and the absence of externally imposed fields.
Inside, a circle at \(s\) encloses \(2M_0\pi s^2/a\). Dividing its circulation by \(2\pi s\) gives
Thus \(\boldsymbol H=\boldsymbol B/\mu_0-\boldsymbol M=0\) both inside and outside here, despite nonzero interior \(\boldsymbol B\). For \(a=20\,\mathrm{mm},M_0=500\,\mathrm{A/m}\), the bulk current density is \(5.0\times10^4\,\mathrm{A/m^2}\), total bulk current \(62.8\,\mathrm A\), and field just inside the rim \(0.628\,\mathrm{mT}\). A magnetometer outside reports zero within this ideal geometry. Such a null measurement establishes neither zero \(\boldsymbol M\) nor absence of all microscopic moments.
Compare a field map and a pickup-coil measurement
A stationary inductive pickup near a stationary permanent magnet has no emf from that static flux alone. An experiment can move the sample, rotate it or modulate a known magnetising field to produce \(-N\,d\Phi/dt\). A Hall sensor or calibrated magnetometer can instead respond to a static field. To compare methods, place a small pickup near the axis of the preceding finite cylinder and oscillate its axial position as \(z=z_0+\zeta\cos\omega t\). For \(\zeta\) small, the flux per turn is approximately \(A_p[B_z(z_0)+\zeta B'_z(z_0)\cos\omega t]\). The voltage amplitude is \(N A_p\zeta\omega |B'_z(z_0)|\). It measures a gradient multiplied by displacement amplitude, whereas a static Hall value measures the field itself.
At the symmetric cylinder centre \(B'_z(0)=0\), so the first harmonic vanishes even though the field is strong. Expanding one more order gives a constant shift and a second harmonic proportional to \(B''_z(0)\zeta^2\), since \(\cos^2\omega t=(1+\cos2\omega t)/2\). Finding a very small first harmonic at the centre is therefore a check on positioning and symmetry. It is not a calibration of zero magnetisation. Far from the ends, a measurement of the whole sample's dipole field instead yields \(\int\boldsymbol M\,dV\). Different internal distributions can share that integral while producing different nearer fields. Report the geometry, the actual observable and the assumed uniformity whenever quoting a single recovered value of \(M\).
Examine bound currents and field measurements in a magnetised sample
Use fictitious poles to compute a measurable field
There is a second useful representation of a given magnetisation. In a simply connected region without free current, \(\nabla\times\boldsymbol H=0\), so choose \(\boldsymbol H=-\nabla\psi\). Substitution into \(\nabla\cdot(\boldsymbol H+\boldsymbol M)=0\) gives
The potential therefore behaves mathematically as if it were produced by volume density \(\rho_m=-\nabla\cdot\boldsymbol M\) and surface density \(\sigma_m=\boldsymbol M\cdot\boldsymbol n\). The surface term follows by extending the magnetisation by zero across the boundary, or by requiring continuity of \(B_n=\mu_0(H_n+M_n)\). Integrate these densities with kernel \(1/(4\pi R)\) to obtain \(\psi\); there is no factor of \(\epsilon_0^{-1}\) because these conventions assign \(\psi\) units of amperes. The resulting \(\boldsymbol H\) must be converted back to \(\boldsymbol B\), adding \(\mu_0\boldsymbol M\) inside matter.
For the uniformly magnetised finite cylinder the pole representation puts densities \(+M\) and \(-M\) on the two end faces, none on the sides. Earlier the bound-current representation placed current on the curved side and none on the ends. They predict the same physical field. A single uniformly loaded disk of pole density \(\sigma_m\) at \(z=0\) has on-axis scalar potential \(\psi=\sigma_m[\sqrt{z^2+a^2}-|z|]/2\), obtained by integrating \(2\pi s\,ds/[4\pi\sqrt{s^2+z^2}]\). Its derivative gives
At the disk plane the two one-sided fields jump by \(\sigma_m\), precisely the normal-\(H\) jump demanded by the magnetisation.
At the midpoint of the cylinder add the two oppositely charged disks. Their axial fields both point opposite the magnetisation and total \(H_z=-M[1-l/\sqrt{a^2+l^2}]\). Adding \(M\) yields the same \(B_z\) as the side-current integral. At \(l=2a\), this internal demagnetising field is \(-0.1056M\); for a very short cylinder \(l\ll a\) it approaches \(-M\). A uniformly specified magnetisation in a thin disc therefore produces only a small normal \(B\) at its centre despite the large \(M\) and \(H\) terms that nearly cancel. In practice, a soft magnetic material in such a shape may choose a nonuniform magnetisation or domains. The calculation describes the field of the imposed distribution; it does not establish that the distribution is a stable material state.
The 'poles' are convenient mathematical source terms, not isolated magnetic charges: adding the effective volume and surface poles over a finite bounded sample gives
North and south effective poles may be far apart, but a surrounding closed Gaussian surface still has zero net magnetic flux. If a model predicts a \(1/r^2\) radial field of one sign through an entire distant sphere around a fully included bar magnet, test whether the opposite face or volume contribution has been accidentally dropped.
Infer the field of a spherical void by subtracting a known sample
Superposition can calculate a local cavity field before introducing a detailed microscopic model. Imagine a large body with uniform imposed magnetisation \(\boldsymbol M\) near an interior point, and remove a small spherical piece. The magnetic field after removal is the original macroscopic field minus the contribution of the excised sphere, provided the surrounding magnetisation stays unchanged. A uniformly magnetised sphere in otherwise empty space alone has uniform internal \(H=-M/3\), as can be derived from its pole distribution \(\sigma_m=M\cos\theta\). At the sphere centre \(\boldsymbol H\) follows by integrating the field from surface elements \(-\sigma_m\hat{\boldsymbol r}\,dA/(4\pi a^2)\). The \(z\)-component involves the spherical average \(\langle\cos^2\theta\rangle=1/3\); transverse contributions vanish by symmetry. The unique dipolar harmonic extends that central value uniformly throughout the sphere.
The sphere's own internal \(B\) is therefore \(2\mu_0M/3\). Immediately after its removal the field in the empty cavity is
This assumes the sphere is small relative to the variation scale of the pre-existing magnetisation and far from the sample's external boundary on its own size scale. A different cavity shape changes the subtraction factor, and a physical bore can rearrange the surrounding magnetisation or admit demagnetising fields from its ends. Local-field interpretations depend on probe geometry as well as material properties.
As a numerical illustration, suppose a permanent or pinned surrounding material has local \(M=1500\,\mathrm{A/m}\) and \(H_{\rm bulk}=400\,\mathrm{A/m}\), aligned. The macroscopic bulk field is \(\mu_0(1900)=2.39\,\mathrm{mT}\). A small spherical empty cavity under the stated frozen-distribution approximation has \(B_{\rm cav}=\mu_0(900)=1.13\,\mathrm{mT}\). Both readings can be correct for the same initial material. A Hall element inserted into a drilled hole measures the field in that hole; labelling it 'the internal material field' without modelling the probe cavity can cause a substantial discrepancy. Small hole volume does not by itself make the local cavity field correction small, since area and inverse-square field factors cancel in the spherical surface integral.
For a final comparison, cut a very thin flat slit perpendicular to \(\boldsymbol M\) instead of a sphere, idealising its lateral dimensions as large relative to its thickness. The facing effective pole sheets produce a strong additional field within the slit. Normal \(B\) stays continuous across its faces, so the vacuum reading tends towards the original normal \(B_{\rm bulk}\) when edge effects and magnetisation changes are negligible. A long narrow cavity parallel to the magnetisation instead tends towards continuity of tangential \(H\) on its long sides. Comparing the sphere and slit is an operational way to understand why \(B\) and \(H\) are different macroscopic variables rather than two symbols for one ambiguous 'magnetic intensity'.
Read the current implied by a magnetisation
Change the magnetisation and compare interior and exterior fields at the surface. Check which tangential or normal field condition is relevant.
Reconstruct an invisible current distribution in a magnetised film
An extended magnetic film fills the slab \(-a<z<a\). A fabrication process leaves a tangential magnetisation \(M_x(z)\hat x\). Let the magnetisation vanish outside. There is no free current in this calculation, and there is no applied field at infinity. A field measurement above the centre of a very wide film can then give nearly zero even when the magnetisation inside varies substantially. Work out both the bound currents and the local magnetic field before deciding what an external zero reading means.
Inside the material the bound volume current is
The upper face has outward normal \(+\hat z\), so its bound sheet current is \(-M_x(a^-)\hat y\). On the lower face the outward normal reverses and the sheet current is \(+M_x(-a^+)\hat y\). Integrating the volume current through the thickness gives \(M_x(a^-)-M_x(-a^+)\). Thus the combined sheet and volume currents sum to zero per unit length across the entire film. This cancellation is independent of how much structure the magnetisation has inside the slab. An alternative derivation extends \(M_x\) by zero beyond the faces and differentiates that piecewise function as a distribution. The jumps generate both surface terms with their proper signs.
For an explicit depth profile take \(M_x=M_0(1+z/a)\). There is a uniform bulk current \(M_0/a\), no lower surface current, and an upper surface current \(-2M_0\). Planar symmetry allows only \(B_x(z)\). Ampère's law gives
Integrating from below the film, where the field vanishes, gives \(B_x=\mu_0 M_0(1+z/a)\) inside. At the upper face the field jumps back to zero. The result also follows directly from \(H_x=B_x/\mu_0-M_x\): its tangential component is continuous wherever there is no free surface current, and there is no volume source for its variation. In this geometry \(H_x=0\) throughout.
Take \(a=0.20\,{\rm mm}\) and \(M_0=2.0\times10^4\,{\rm A/m}\). The interior current density is \(1.0\times10^8\,{\rm A/m^2}\). That large number represents microscopic circulating moments after coarse graining. It does not imply a transport current passing through external electrical contacts. The peak interior field is approximately \(50.3\,{\rm mT}\) just below the upper face, and the average is about \(25.1\,{\rm mT}\). An exterior sensor over the central region of the infinite idealisation reads zero at any height. With a finite lateral extent, currents must close around the film edges. The resulting fringe signal contains shape information and becomes measurable as the probe approaches the rim.
Rotate the magnetisation through ninety degrees so that it now points in the \(z\) direction while its magnitude keeps the same depth profile. Each local curl vanishes. Each face has parallel magnetisation and normal, giving zero bound sheet current. Consequently the solution has zero \(B\) everywhere in the ideal infinite geometry. Within the film \(H_z=-M_z\). In the magnetic-pole construction the two surface pole densities and the bulk density \(-dM_z/dz\) provide precisely that auxiliary field. These two slab examples illustrate a real inverse problem: very different internal magnetic states can produce the same exterior measurement. Knowing the material orientation or imposing a changed external field supplies additional information.
Can two depth profiles with the same average magnetisation be distinguished by an ideal measurement of the tangential magnetic flux through the film thickness?
Work through the solution
Choose a rectangular sensing surface with its normal along \(x\), its height equal to the film thickness, and its length \(w\) along \(y\). The ideal internal flux is \(w\mu_0\int_{-a}^{a}M_x(z)\,dz\). This measurement determines one weighted integral. A constant \(M_0\) and the linear example above give identical results even though the constant profile has only surface currents. A depth-selective measurement would weight the profiles differently. For example, integrating over just the upper half gives \(\mu_0waM_0\) in the constant case and \(3\mu_0waM_0/2\) in the linear case. Actual pickup loops must close outside the sample, so include their full geometry when inferring an internal flux.
Suppose the linear profile relaxes uniformly in amplitude after an aligning field is removed. What information would the integrated voltage of a calibrated pickup provide?
Work through the solution
If the pickup links \(N\) turns with the preceding full-thickness flux and \(M_0\) decays from its initial value to zero, the time-integrated emf has magnitude \(2N\mu_0waM_0(0)\). Faraday's law supplies this integral independently of whether the decay is exponential or has several relaxation times. A finite integration window that ends before zero magnetisation underestimates the initial amplitude unless the residual flux is measured. Leakage from the changing applied alignment field can also drive the loop directly. A reference winding of the same area, measured without the specimen, allows that part of the transient to be estimated.
David Tong, Electromagnetism in Matter, on macroscopic magnetisation and bound currents.
Tutorial on reconstructing material sources
In the nonuniform cylinder let \(M_\varphi=M_0(s/a)^3\) instead. Obtain the bulk current density, the side sheet, the total bound current through the full cross section and the interior field.
Work through the solution
At the wall \(K_{b,z}=-M_0\). Integration gives \(2\pi aM_0\) in the bulk and its opposite on the wall. For an interior circle the enclosed bulk current is \(2\pi M_0s^4/a^3\), giving \(B_\varphi=\mu_0M_0(s/a)^3\). Both total cancellation and dimensional consistency check the result.
Two adjoining media have tangential magnetisations \(400\hat{\boldsymbol x}\) and \(100\hat{\boldsymbol x}\,\mathrm{A/m}\). The normal from 1 to 2 is \(+\hat{\boldsymbol z}\). Find the net bound sheet current and the associated tangential jump of \(\boldsymbol B\) if no free surface current is present.
Work through the solution
The equivalent sheet is
Tangential \(H_x\) is continuous, so
Crossing this difference with the chosen normal gives \(\mu_0\boldsymbol K_b\), matching the microscopic Ampère law.
A long solenoidal sample has known \(M\) only to 5 percent. Can a single Hall reading at the centre establish that its magnetisation is uniform over the entire volume to that accuracy?
Work through the solution
No. The reading is one geometry-weighted integral of the source. Reversing magnetisation can remove a stable external offset, and measurements at several axial positions can test the uniform-cylinder shape, but the single central datum cannot uniquely determine a spatially resolved source. Agreement of a fitted constant at one point supplies no independent uniformity test.
Interfaces, demagnetising fields and the work of magnetisation
Magnetism, induction and field dynamics
Two samples made of the same material can respond very differently to an externally applied field if one is a long rod and the other is a thin disc. The induced moment depends on the internal field, which the magnetised sample helps create. The same distinction reappears when one tries to infer a force from stored magnetic energy.
Introduce the auxiliary field by removing a known current
With magnetisation present the total steady current is \(\boldsymbol J_f+\nabla\times\boldsymbol M\), where the curl includes any sheet contribution if \(\boldsymbol M\) is extended distributionally. Define \(\boldsymbol H=\boldsymbol B/\mu_0-\boldsymbol M\), giving \(\nabla\times\boldsymbol H=\boldsymbol J_f\). A small ribbon crossing an interface with normal \(\boldsymbol n\) directed from 1 to 2 gives \(\boldsymbol n\times(\boldsymbol H_2-\boldsymbol H_1)=\boldsymbol K_f\), and a thin pillbox gives
The boundary conditions distinguish the field whose circulation counts free current from the field whose flux has no sources.
If both media are linear, isotropic and local,
In the absence of free surface current \(H_t\) and \(B_n\) are continuous. For angles measured from the normal, \(\tan\theta=B_t/B_n\) therefore gives \(\tan\theta_2/\tan\theta_1=\mu_2/\mu_1\) when the nonzero components permit the ratio. For instance, going from vacuum into a medium with \(\mu_r=5\), let \(B_{1n}=2\,\mathrm{mT}\) and \(B_{1t}=1\,\mathrm{mT}\). The new components are \(2\) and \(5\,\mathrm{mT}\), tilting the local field from \(26.6^\circ\) to \(68.2^\circ\). A mounted probe sensitive only to the normal component would register no jump. This local argument says which components can jump; it does not solve the complete field of a finite piece of material.
Solve a sphere to find its internal field
Put a uniform isotropic sphere of radius \(a\) and permeability \(\mu_r\mu_0\) in an originally uniform external \(\boldsymbol H_0=H_0\hat{\boldsymbol z}\). There is no free current in or near it, so locally \(\boldsymbol H=-\nabla\psi\). In each uniform domain \(\nabla\cdot\boldsymbol B=0\) implies Laplace's equation for \(\psi\). Spherical symmetry of the geometry and the linear far-field potential select the angular harmonic \(\cos\theta\). The finite interior solution is \(-C r\cos\theta\); the exterior is \(-H_0r\cos\theta+D\cos\theta/r^2\). Tangential \(H\) agrees at the surface when \(\psi\) is continuous up to a chosen common constant. Normal \(B\) enforces the second equation:
Inside, \(H_{\rm int}=C\) is uniform. Multiplying by susceptibility \(\chi=\mu_r-1\) gives
Rearranging yields the memorable self-consistency relation \(H_{\rm int}=H_0-M/3\). The factor \(1/3\) came from solving both boundary conditions for a sphere and is not a universal material property. The dipolar exterior carries moment \(m=4\pi D=(4\pi a^3/3)M\), as expected from summing the uniform magnetisation. An ellipsoid with a principal axis parallel to the drive can likewise have uniform magnetisation and \(H_{\rm int}=H_0-N_dM\) with a geometric demagnetising factor; an arbitrary block usually has spatial variations near edges.
Take \(\mu_r=10\) and \(H_0=200\,\mathrm{A/m}\). The sphere has \(H_{\rm int}=50\,\mathrm{A/m}\), \(M=450\,\mathrm{A/m}\) and \(B_{\rm int}=0.628\,\mathrm{mT}\). A naive use of \(M=9H_0\) would give four times the actual moment. A long narrow specimen parallel to the drive, with very small \(N_d\), comes much closer to that latter value if the material remains linear. For the sphere \(\mu_r\to\infty\) gives \(B_{\rm int}\to3\mu_0H_0\) rather than infinity; meanwhile \(H_{\rm int}\to0\). These two trends are compatible because \(B/H\) is growing. Calling either simply a 'field enhancement' without specifying the measured field obscures the limiting result.
Derive the incremental energy for a reversible medium
Imagine increasing the current in a winding slowly while holding all material boundaries fixed. Faraday's law makes the terminal voltage, apart from resistance, \(d\lambda/dt\), where \(\lambda\) is the flux linkage. The source delivers incremental energy \(I\,d\lambda\). In a uniform toroidal core of mean path length \(\ell\), area \(A\), and \(N\) turns,
Therefore \(I\,d\lambda=(A\ell)H\,dB\). In a lossless quasistatic medium the magnetic energy density accumulated along a reversible constitutive path is \(w(B)=\int_0^B H(B')\,dB'\). When \(B=\mu H\) with constant \(\mu\), this reduces to \(BH/2\). The corresponding coenergy \(w'(H)=\int_0^H B(H')\,dH'\) satisfies \(w+w'=BH\) for a single-valued curve through the origin.
As a nonlinear example, use \(H=\alpha B+\beta B^3\) with \(\alpha=10^3\,\mathrm{A/(m\,T)}\) and \(\beta=4.0\times10^3\,\mathrm{A/(m\,T^3)}\) over the measured range. At \(B=0.50\) T, \(H=1000\,\mathrm{A/m}\). The integrated energy is
half the endpoint product gives \(250\,\mathrm{J/m^3}\) and misses the curvature. Coenergy is \(312.5\,\mathrm{J/m^3}\), compensating the difference. The differential permeability is \(dB/dH=(\alpha+3\beta B^2)^{-1}=2.50\times10^{-4}\,\mathrm{H/m}\), whereas the ratio \(B/H=5.00\times10^{-4}\,\mathrm{H/m}\). A small alternating signal about a DC operating point samples the differential value. These numbers are properties of the model curve and should not be mistaken for a universal ferromagnetic law.
Add an air gap and localise the energy
Give a toroidal magnetic circuit a thin gap of length \(g\), neglecting fringing, leakage and flux crowding. For equal cross sections the same normal \(B\) passes through core and gap. Ampère's law gives
For linear \(\mu_r\), this yields
With \(\ell_c=0.20\,\mathrm m,\ g=1.0\,\mathrm{mm},\ \mu_r=1000,\ NI=100\) A-turns the result is \(0.1047\) T. The gap consumes \(83.3\) A-turns; the much longer core consumes \(16.7\). Vary the two lengths separately to see why high permeability cannot remove the gap contribution.
Their energy ratio follows from \(B^2/(2\mu)\) times volume, giving \(U_g/U_c=g\mu_r/\ell_c=5.0\). For area \(A=1.0\,\mathrm{cm^2}\), the gap stores \(0.436\,\mathrm{mJ}\) and the core \(0.0873\,\mathrm{mJ}\). The simple force scale at one nearly uniform normal gap face is
Decreasing \(g\) at fixed current changes the total flux, so differentiating only the instantaneous gap energy while holding everything else implicitly fixed need not reproduce the mechanical force. One may use a vacuum stress surface or a coenergy derivative at prescribed current. Both methods require a clear statement about what is held fixed during the imagined displacement.
Distinguish reversible storage from a measured loop
Real ferromagnetic samples can have history-dependent magnetisation. If \(B\) and \(H\) trace a closed hysteresis loop, the integral \(\oint H\,dB\) measures energy per volume delivered in one quasistatic cycle, with a positive sign for a dissipative cycle under passive conventions. A single-valued energy density of \(B\) alone cannot reproduce this nonzero path integral. At finite frequency conductive eddy losses and relaxation can broaden a measured loop, so a loop measured at one rate alone cannot isolate a purely quasistatic hysteresis loss.
For an approximately parallelogram-shaped cycle spanning switching fields \(\pm120\,\mathrm{A/m}\) and switching induction swing \(0.80\,\mathrm T\) from lower to upper branch, its approximate enclosed area is \(240\times0.80=192\,\mathrm{J/m^3}\) per cycle. At 50 Hz a \(12\,\mathrm{cm^3}\) sample dissipates approximately \(0.115\,\mathrm W\). The stated swing here is the full separation, eliminating a common factor-of-two ambiguity. A power meter on the terminals also sees the winding's \(I^2R\) and any energy leaving the apparatus; a separate resistance measurement and a frequency sweep help isolate the material contribution.
Reconstruct an anisotropic interface from boundary data
At an interface with a single crystal the relation between \(\boldsymbol H\) and \(\boldsymbol B\) may be tensorial. The formulas for angle refraction derived earlier assume scalar permeability; the underlying boundary conditions do not. Take a planar interface with normal \(+\hat{\boldsymbol z}\), vacuum below and a linear reciprocal crystal above. Choose units such that its relative permeability in the \(x,z\) plane is the symmetric matrix with entries \(\mu_{xx}=4,\mu_{xz}=\mu_{zx}=1,\mu_{zz}=2\). Its positive determinant and positive diagonal make the associated magnetic energy positive. Suppose the vacuum drive near the boundary has \(H_{1x}=100\,\mathrm{A/m}\) and \(B_{1z}/\mu_0=200\,\mathrm{A/m}\), with no \(y\) component and no free sheet current. These are local interface data, not a complete boundary condition for a finite crystal.
Continuity of tangential \(H\) gives \(H_{2x}=100\). Continuity of normal \(B\) gives \(100+2H_{2z}=200\), hence \(H_{2z}=50\,\mathrm{A/m}\). The crystal's tangential flux density then follows from \(B_{2x}/\mu_0=4(100)+50=450\,\mathrm{A/m}\); \(B_{2z}/\mu_0=200\) by construction. In the crystal \(\boldsymbol H\) and \(\boldsymbol B\) point at different angles to the normal, with tangent ratios 2 and 2.25 respectively. The local reversible magnetic energy density is
Replacing the tensor by a scalar fitted to the normal component would give the wrong tangent field and energy even though that fitted scalar reproduces one measurement by design.
For a general symmetric matrix, the cross energy in \(w(\boldsymbol H)=\boldsymbol H\cdot\boldsymbol\mu\boldsymbol H/2\) involves both off-diagonal elements. Its derivative with respect to one component yields the corresponding component of \(\boldsymbol B\). One can test reciprocity by preparing two small field increments about the same reversible operating point and interchanging their directions. The mixed incremental energy should agree. Large hysteresis loops, saturation along an easy axis or externally biased nonreciprocal media require more information before equating the two cross responses. The scalar material tables often used for a gapped iron core therefore encode a particular direction and operating regime.
Determine a demagnetising factor or an intrinsic susceptibility
For an ellipsoidal sample along a principal axis, combine \(H_{\rm int}=H_0-N_dM\) with \(M=\chi H_{\rm int}\). Define apparent susceptibility \(\chi_{\rm app}=M/H_0\). Rearrangement gives
This linear relation suggests a comparative measurement that can separate material and shape without having a probe inside either sample. Prepare geometrically distinct ellipsoids from one linear isotropic material, measure their moments along specified axes in the same calibrated uniform field, and divide by their respective volumes. If their demagnetising factors are independently known and the material history has not changed, the quantities \(1/\chi_{\rm app}-N_d\) should agree.
Take intrinsic \(\chi=20\). A sphere with \(N_d=1/3\) gives \(\chi_{\rm app}=2.609\); a slender ellipsoid with \(N_d=0.050\) gives \(\chi_{\rm app}=10.0\). One might attribute their nearly fourfold moment ratio to different compositions if the shapes were omitted. Suppose the measured slender-sample value is \(9.0\) instead. Its inferred intrinsic susceptibility would be \(1/(1/9-0.05)=16.36\). Comparing the sphere's inferred value of 20 tests whether the discrepancy exceeds shape, volume and magnetometer uncertainties. The inversion is especially ill-conditioned near the large-\(\chi\) apparent saturation \(1/N_d\); small errors in a heavily demagnetised sample then produce large errors in the recovered intrinsic response.
The sensitivity can be quantified without introducing a fitting convention. Differentiate \(\chi=\chi_{\rm app}/(1-N_d\chi_{\rm app})\), giving \(d\chi/d\chi_{\rm app}=1/(1-N_d\chi_{\rm app})^2\). At the preceding spherical point this derivative is nearly 59, so an absolute error 0.02 in the apparent value shifts the recovered intrinsic result by about 1.18. For the slender sample the derivative is only four at the stated point. The large spherical amplification follows from subtraction of nearly equal quantities, not poor electrical calibration. An elongated specimen may therefore yield a more informative intrinsic measurement even if a sphere is easier to machine and align.
Check a material explanation against mechanical and electrical work
Imagine measuring a single coil fitted with an adjustable magnetic insert. At a particular position the current ramp up from zero to 0.50 A produces linkage \(\lambda(I)=aI+bI^3\) with \(a=0.040\,\mathrm H\), \(b=-0.020\,\mathrm{H/A^2}\) over this restricted range. Differential inductance is \(a+3bI^2\) and stays positive here. Stored energy is \(\int I\,d\lambda=aI^2/2+3bI^4/4\), whereas coenergy is \(\int\lambda dI=aI^2/2+bI^4/4\). At the stated end current they are \(4.06\) and \(4.69\) mJ. Their sum \(8.75\) mJ equals \(I\lambda\). A measured terminal waveform can integrate the first expression directly by accumulating \(I(v-RI)dt\); independently plotting \(\lambda\) versus \(I\) allows the second by planimetric integration. These two areas have different shapes on a nonlinear constitutive curve.
If the insert moves, coenergy at each position can be obtained by repeating the reversible \(\lambda(I)\) scan. Its spatial difference divided by travel distance estimates the average force for fixed end current. Simply using half the product of the end current and linkage would predict neither energy correctly in this example. A hysteretic insert follows different curves on raising and lowering the current, so a measured mean force or cycle loss must state the prepared branch. A force predicted by one reversible branch can be checked with a load cell at the same position and current; an electrical scan at another bias is not enough to test the mechanical boundary condition.
Put the magnetic energy on the correct side of a gap
Change the reluctance of a narrow air gap and inspect which section controls flux. Check the assumptions needed before replacing the complete field with a circuit.
Derive the directional permeability of a stack of thin layers
A material assembled from alternating sheets can respond differently to fields along and across the sheets even when each constituent is isotropic. Consider many parallel layers of two linear, reversible magnetic materials with absolute permeabilities \(\mu_1\) and \(\mu_2\). Their volume fractions in a representative period are \(f\) and \(1-f\). Start far from the outer edges. Suppose the imposed field varies only on lengths much longer than a period, and take the frequency low enough that eddy currents do not change the field distribution. These conditions make a comparison with homogeneous bulk measurements meaningful.
First apply a field tangent to the layers. The tangential field \(H_t\) is continuous at each interface because no free sheet current flows there. Each material has a different magnetic induction \(B_{it}=\mu_i H_t\). Averaging the induction over one period and dividing by the shared field gives
This is an arithmetic mean. A heavily permeable layer can carry a large fraction of the tangential flux through only part of the period. No condition requires equal tangential induction on the two sides of the internal interface.
Next drive the magnetic flux through the stack in the normal direction. Normal induction is continuous because magnetic flux lines cannot end at a layer. The normal field in each layer is \(B_n/\mu_i\). Averaging the field at fixed common induction now gives a harmonic mean,
A small fraction of a weakly permeable spacer can account for most of the magnetomotive drop across a stack. One can derive the same result by adding the magnetic reluctances of a column of common area. That circuit calculation works here because the interface conditions guarantee a common induction. Tilting the applied field creates both normal and tangential components and requires both averages at once. In axes attached to the layers,
The averaged field vectors are generally not parallel.
For a stack containing \(90\%\) by volume of a material with relative permeability \(1000\) and \(10\%\) of a spacer with relative permeability one, the two effective relative permeabilities are \(900.1\) and approximately \(9.91\). Suppose a fixture produces equal average components \(H_t=H_n=10\,{\rm A/m}\). The induction components are then about \(11.31\,{\rm mT}\) and \(0.125\,{\rm mT}\). Their ratio corresponds to an induction angle only \(0.63^\circ\) above the layers while the average field points at \(45^\circ\). A probe sensitive to a single component could therefore return an apparently inconsistent permeability when the orientation of an anisotropic specimen is ignored.
Verify the energy before using the homogenised material law. For a purely normal induction the microscopic average energy density is
For tangential field the microscopic average is
Adding both contributions gives \(\langle\mathbf B\rangle\cdot\langle\mathbf H\rangle/2\) for this linear model. Directly replacing each constituent field by the spatially averaged field before evaluating its energy would give an incorrect normal contribution. The field concentration in the spacer is a physical effect that survives passage to an effective continuum.
Estimate how precisely the spacer fraction must be known if a low-frequency normal-induction calibration is to be reproducible.
Work through the solution
Write \(s=1-f\) and \(\mu_{\perp,r}=[(1-s)/1000+s]^{-1}\). Differentiating its logarithm gives \(d\ln\mu_{\perp,r}/ds=-0.999/[0.001+0.999s]\), about \(-9.90\) at \(s=0.10\). Increasing the spacer volume fraction by one absolute percentage point therefore reduces normal permeability by roughly ten percent to first order. Direct substitution at \(s=0.11\) gives \(9.02\), or a reduction of about nine percent, showing the size of the linearisation error for that relatively large change. The same change reduces the tangential relative permeability from \(900.1\) to \(890.1\), only about one percent.
How does local saturation change the normal and tangential experiments?
Work through the solution
In the normal test the induction is shared. A high-permeability layer reaches a specified saturation induction at approximately the same common induction one measures outside a suitably shaped test column. In the tangential test the field is shared and the high-permeability phase can have a much larger local induction than the reported average. For an infinitesimal variation around a bias point, repeat the interface argument with the local differential permeabilities \(dB_i/dH_i\). The differential effective response obeys the same arithmetic or reciprocal averaging rules under the one-dimensional hypotheses. A finite path that traverses a hysteresis loop needs its history and dissipation as well; no single constant differential permeability specifies its loop area.
David Tong, Electromagnetism in Matter, on constitutive laws and material interfaces.
Tutorial on geometry and constitutive response
A spherical sample has apparent susceptibility \(M/H_0=2.4\). Infer its intrinsic linear susceptibility and the internal field fraction. Can an apparent value of 3.5 arise in this model with positive intrinsic susceptibility?
Work through the solution
For a sphere \(M/H_0=\chi/(1+\chi/3)\). Inversion gives
Positive finite \(\chi\) gives apparent values less than three. A measured larger result would call for checking shape, units, background or the linear homogeneous assumption.
An unknown material is placed in a long gapped circuit. At a given operating point twice the current gives only 1.6 times the old induction. Can a fixed linear permeability with unchanged geometry explain it?
Work through the solution
A fixed linear reluctance at fixed geometry gives exactly proportional induction. One can infer \(H_c=(NI-Bg/\mu_0)/\ell_c\) at each point and compare the results with a measured constitutive curve. Field-dependent permeability, leakage, fringing or a changing physical gap would each need evaluation before calling the effect saturation.
An interface has no sheet current, the normal field happens to vanish on both sides, and the tangential magnetic flux density differs by a factor of eight. What material ratio follows if both media are scalar and linear? Does this require a discontinuity in \(H_t\)?
Work through the solution
Continuity of \(H_t\) gives \(B_{2t}/B_{1t}=\mu_2/\mu_1=8\) if the tangential drive is nonzero. No tangential \(H\) jump is needed. The magnetisation jump can supply an equivalent bound surface current producing the jump in \(B_t\).
Measure how quickly a dielectric follows an electric field
Fields and the response of matter
Derive the time and frequency responses of a relaxing polarisation, locate the loss maximum and decide whether a measured sample contains more than one relaxation process.
From a delayed polarisation to a constitutive equation
A slab of insulating material is placed between parallel electrodes. At first the measured charge increases very quickly when a small voltage is switched on. It then continues to rise slowly even though the applied voltage is fixed. A constant real relative permittivity can describe the final charge but cannot predict this record. The experiment reveals at least two relevant time scales. For a measurement window that resolves only the slower process, treat the fast electronic response as instantaneous and describe the slower polarisation \(P\) by its approach to an equilibrium value.
At fixed weak field the equilibrium slow polarisation is \(\epsilon_0\Delta\epsilon E\), with \(\Delta\epsilon>0\). Assume the rate of change is proportional to the distance from that equilibrium, with one positive relaxation time \(\tau\). Then
This is a phenomenological material law. Its assumptions include linear response about the prepared state, a time-independent \(\tau\), and a sample whose constituents can be described by one dominant relaxation. Testing those assumptions is part of the experiment.
For \(E(t)=E_s\) switched on at zero from an unpolarised state, solve using the integrating factor \(e^{t/\tau}\). The result is
After one \(\tau\), 63.21% of the slow response has developed; after \(3\tau\), 95.02%. Measuring an absolute fraction requires subtracting the fast initial jump and knowing the eventual plateau. A long baseline drift can look like a second relaxation if those references are not controlled.
Derive the complex dielectric response
Now use peak phasors with time dependence \(e^{-i\omega t}\). Differentiation contributes \(-i\omega\), so
Include the high-frequency relative permittivity \(\epsilon_\infty\), where “high” means above the slow process but below additional electronic resonances. The real and imaginary parts of relative permittivity are
At fixed field amplitude the polarisation current is
The mean electrical work per unit time and volume is
Loss therefore has positive \(\epsilon''\) in the chosen time convention. Using \(e^{+i\omega t}\) reverses the sign of the imaginary part of permittivity but leaves mean absorbed energy positive when the current convention is changed consistently.
Set \(u=\omega\tau\). Differentiating \(u/(1+u^2)\) gives \((1-u^2)/(1+u^2)^2\). Hence \(\epsilon''\) peaks at \(u=1\), with height \(\Delta\epsilon/2\), and the real part lies halfway between its low- and high-frequency plateaux. The peak identified here is in the imaginary *permittivity*. A plot of dissipated power at fixed field includes an additional factor of frequency and need not have a peak at the same location.
Tie a frequency sweep to a step test
Suppose a material has \(\epsilon_\infty=2\), \(\Delta\epsilon=6\), and a measured loss peak at 1 kHz. Then \(\tau=1/(2\pi\,1000)\simeq159\ \mu\mathrm s\). At the peak the relative permittivity is \(5+3i\) in our convention. A time-domain voltage step should show a slow charge transient reaching 63.2% of its added charge in roughly 159 μs. This comparison connects two experiments that weight electrode offsets and parasitic impedances differently.
An independent shape check follows by eliminating \(u\). Let \(X=\epsilon'-\epsilon_\infty\) and \(Y=\epsilon''\). From the formulas \(X^2+Y^2=\Delta\epsilon X\). Thus \((X-\Delta\epsilon/2)^2+Y^2=(\Delta\epsilon/2)^2\): a single Debye relaxation traces a semicircle in the complex plane. Departures from a semicircle can reflect several relaxation times, spatially inhomogeneous samples, leakage or imperfect fixture correction. They do not uniquely identify the microscopic mechanism.
Resolve a second process only when the data require it
The synthetic sample has two groups contributing a fixed total \(\Delta\epsilon=6\). Change the fraction in the slower group and its relaxation time relative to the faster group. At equal relaxation times the groups give exactly the single-process response whatever their fractions. When the times differ, the imaginary curves broaden and may separate. Observe the real dispersion steps as well. A broad lossy peak alone can be fitted by more than one pair of times and strengths.
In a practical measurement the low-frequency tail can contain DC conductivity. In the \(e^{-i\omega t}\) convention,
This added imaginary part is proportional to \(1/\omega\), whereas the low-frequency side of an isolated Debye relaxation rises as \(\omega\). Change electrode separation and use a DC conduction measurement to challenge the interpretation. An electrode interface can add a further time scale, so an observed fit parameter deserves an uncertainty and a physical validation step.
Tutorial
The loss maximum is at 2 kHz and its height is 4 in relative-permittivity units. The high-frequency plateau is 3. Predict the low-frequency plateau and the slow response at \(t=100\,\mu\mathrm s\) after a step.
Work through the solution
The single-time model gives \(\Delta\epsilon=8\) and the low-frequency plateau 11. The relaxation time is \(1/[2\pi(2000)]\simeq79.6\,\mu\mathrm s\). The slow fraction after 100 μs is \(1-e^{-100/79.6}\simeq0.715\). Repeat at another step amplitude to check linearity.
At the loss peak, is the phase difference between the *total* displacement and the electric field always 45°?
Work through the solution
The slow polarisation alone has a 45° phasor angle at \(\omega\tau=1\). The total displacement includes \(\epsilon_\infty E\). Its angle is \(\arctan[(\Delta\epsilon/2)/(\epsilon_\infty+\Delta\epsilon/2)]\), generally less than 45°.
Why does observing only a high-frequency tail constrain a ratio of parameters more tightly than the individual parameters?
Work through the solution
For large \(\omega\tau\),
Many values with the same ratio \(\Delta\epsilon/\tau\) have very similar tails. Measure the peak or both plateaux to distinguish the two parameters.
Compare with material measurements
Inspect the orientational response and dielectric-loss treatment in MIT's material-properties course. Use the phasor convention of each source to predict the sign assigned to loss.
Identify mobile charge with a transverse field
Fields and the response of matter
Derive a Hall-voltage measurement from transverse force balance, reverse current and field to reject offsets and explore what fails when two carrier types conduct.
Choose signs from a drawing
A rectangular conducting sample has its long axis along \(x\), width \(w\) along \(y\), and thickness \(t\) along \(z\). A uniform magnetic field \(B\hat{\mathbf z}\) is applied. An external circuit maintains conventional current \(I>0\) in \(+x\). High-impedance transverse probes draw negligible current. Define the measured signal as \(V_H=V(y=0)-V(y=w)\). For uniform transverse field this convention gives
Reversing the voltmeter leads reverses the reported sign; writing a carrier sign without a lead convention is incomplete.
With one charge carrier species of number density \(n\) and signed charge \(q\), the drift velocity satisfies
If the transverse velocity vanishes, its magnetic force component is \(-qv_xB\), opposed by \(qE_y\). Thus \(E_y=v_x B=j_xB/(nq)\). The resulting port measurement is
The width cancels for a uniform bar; changing the contact geometry or using a current source with a nonuniform injection profile can spoil that simplification near the terminals. The cancellation also exposes the sign. For electrons \(q<0\), positive conventional current means that the mobile charge drifts in \(-x\). The inferred transverse field is negative for positive \(B\) in the chosen convention.
Reconstruct density and mobility from separate observations
Take \(t=0.50\) mm, \(I=5.0\) mA, \(B=0.20\) T and a transverse signal of \(-1.25\) mV. The inferred signed Hall coefficient is
Using singly charged electrons gives
A longitudinal voltage measurement, after correcting for probe separation, can yield the material conductivity. If \(\sigma=80\) S/m, the single-carrier mobility is
These operations use different pieces of information. The longitudinal measurement alone gives only the product \(n|q|\mu\). The transverse measurement supplies a sign and, in the one-carrier model, the density independently of mobility. This is an inverse experiment whose two observables have different sensitivities, not a more precise measurement of the same scalar.
One can derive the same result from a stationary Drude equation \(0=q(\mathbf E+\mathbf v\times\mathbf B)-m\mathbf v/\tau\). The longitudinal drag gives
force balance in \(y\) gives the transverse field just obtained. In a homogeneous single-carrier sample, \(E_y/E_x=q\tau B/m\), the signed Hall angle tangent. At fixed sample and field, doubling \(I\) doubles both voltages in this linear regime and leaves their ratio unchanged. Significant current-dependent apparent density can indicate heating or nonlinear contacts.
Isolate the transverse voltage from a misaligned contact
Practical side contacts seldom sit at exactly the same \(x\). A fraction of the longitudinal voltage can leak into the transverse pair. Write the readout at a fixed current as \(V_\mathrm{m}(B)=V_0+\alpha V_{xx}+V_H(B)\). A background that is even in field cancels in \([V_\mathrm m(B)-V_\mathrm m(-B)]/2\). For example, readings of 3.05 mV and 5.55 mV at \(+B,-B\) return \(-1.25\) mV Hall signal and 4.30 mV of even background. Taking a single measured sign would have diagnosed the wrong carriers.
The plot deliberately superposes a constant 4.3 mV pickup on a signed Hall signal. Vary density and current independently before reading the pair at \(B=\pm0.2\) T. Large density weakens the signal; current increases it. Verify that field reversal recovers the correct transverse voltage even when both instrument readings have the same sign. If the unwanted background changes between readings, reverse the field several times and check for repeatable drift.
With both current and field reversal, the double-odd combination \([V(+I,+B)-V(+I,-B)-V(-I,+B)+V(-I,-B)]/4\) isolates terms odd in both. A thermal emf that is independent of current cancels along with a stable contact offset. This symmetry decomposition is a physical assumption about the parasitics, so preserve all four readings and inspect the rejected channels too.
When a Hall density stops being a particle count
With electrons and holes, longitudinal conductivities add. In a weak magnetic field their transverse contributions also depend on squared mobilities. For positive mobilities \(\mu_e,\mu_h\) and electron and hole densities \(n,p\), the two-carrier weak-field coefficient in the sign convention above is \(R_H=(p\mu_h^2-n\mu_e^2)/[e(p\mu_h+n\mu_e)^2]\). To see where the square appears, note that one factor of mobility converts the longitudinal field into drift; a second converts the resulting transverse magnetic force into a drift contribution. Summing species currents and imposing zero total transverse current gives the denominator management through the summed longitudinal conductivity.
Equal electron and hole densities with equal mobilities give zero Hall signal while current still flows readily. A single-species inversion would suggest unbounded density. At equal densities but unequal mobilities, the faster species can set the sign even though neither species is more numerous. Additional field dependence, temperature variation and independent structural information are needed before treating a Hall number as a carrier census.
Tutorial
A measurement doubles the width \(w\) at fixed thickness, total current and field in a uniform sample. Predict both \(E_y\) and \(V_H\).
Work through the solution
The current density halves, so \(v_x\) and \(E_y\) halve. The voltage integrates that halved field over twice the width and stays the same. If fixed current density were held instead, the transverse voltage would double.
A nominal thickness is overestimated by 5%. What bias does this cause in the single-carrier density inferred from a fixed transverse signal?
Work through the solution
\(n=|IB|/(e t|V_H|)\), so using \(1.05t\) gives \(n_\mathrm{fit}=n/1.05\), approximately 4.8% low. This systematic error is common to all repeated field sweeps.
Why might a metal yield a smaller Hall voltage than a semiconductor with the same dimensions at the same current?
Work through the solution
In the one-carrier regime the signal is inversely proportional to carrier density. A large density allows the imposed current at a very small drift speed, requiring a correspondingly small transverse balancing field. Conductivity alone cannot determine this comparison without mobility information.
Follow the transport model
Compare the one-carrier assumptions with the treatment of mobile carriers in David Tong's solid-state physics course. Connect an independently measured conductivity with the signed transverse response before interpreting an effective mass or scattering time.
When does a polar crystal change its preferred state?
Fields and the response of matter
Derive stable and unstable dielectric responses from a free-energy landscape. Separate a reversible small-signal capacitance from a switching experiment.
Why one voltage can support several measured polarisations
Some insulating crystals develop a spontaneous electric polarisation as temperature is lowered. The high-temperature phase may be symmetric under inversion so that states with polarisation \(+P\) and \(-P\) are equivalent in zero field. Near a continuous transition, treat one component of polarisation as an order parameter. A local free-energy density compatible with the symmetry is \(f(P)=a(T-T_c)P^2/2+bP^4/4\) with \(a,b>0\). The omitted terms limit how far in temperature or field this truncated expansion is reliable. The positive quartic term keeps the energy bounded when the quadratic coefficient is negative.
For a device whose applied electric field \(E\) is controlled, the appropriate potential in this simple model is \(g(P;E)=f(P)-EP\). The linear term records external work; changing what is held fixed changes the energy to minimise. Differentiation gives the constitutive equation \(E=a(T-T_c)P+bP^3\). An algebraic root is an equilibrium candidate. A stable local response also requires positive second derivative \(a(T-T_c)+3bP^2\). A very accurate rootfinder can return an unstable stationary point if this second test is omitted.
Find the equilibrium branches and their response
Introduce scaled polarisation \(p\), field \(e\) and temperature parameter \(s\) such that \(g=p^4/4+sp^2/2-ep\). Then \(e=p^3+sp\). For \(s>0\), the slope \(3p^2+s\) stays positive. Each field has one stable solution. At \(e=0\), \(p=0\) and the small-signal susceptibility \(dp/de=1/s\) increases when approaching the ideal critical point from above.
For \(s=-1,\ e=0\), stationary values are \(-1,0,+1\). The middle root has curvature −1 and is a local maximum. Each outer root has curvature 2 and is a minimum. The susceptibility about a selected outer state is \(1/2\) in the scaled units. The fact that the two domains can carry opposite zero-field polarisation does not make the harmonic response negative. The mere existence of a negative-slope segment in the cubic constitutive curve is insufficient to infer a stable isolated small-signal device with that differential response.
Derive the limit of a metastable homogeneous state
Imagine preparing the negative-polarisation state at \(s=-1\), then increasing the applied field slowly. A positive field lowers the energy of the positive state. The negative state can persist locally behind a barrier even after it ceases to be the global minimum. A model of perfectly homogeneous evolution without early nucleation follows this metastable branch until the curvature vanishes. Solve \(3p^2-1=0\), choose \(p=-1/\sqrt3\), and insert it into \(e=p^3-p\). The positive limiting field is
At the opposite spinodal the signs reverse.
This is a limit of the particular energy model. Real switching can occur earlier through domain walls, nucleation, defects or thermally activated barrier crossing. Observing a smaller coercive field in a specimen is not evidence that the cubic equation was solved inaccurately. To compare an actual hysteresis loop with a calculation, state the sweep rate, boundary circuit, sample preparation and a dynamical or nucleation model in addition to equilibrium free energy.
Read a landscape rather than tracing an unlabelled loop
Set \(s=-1\). At zero applied field, locate the two equal wells. Increase positive \(e\) gradually and watch the negative well become shallower. The browser locates real stationary points of the cubic, classifies them by curvature and reports their positions. Its plotted potential shows the energy barrier separating basins. Choose \(s>0\) and repeat to see why fitting the same S-shaped hysteresis loop above a continuous transition would be inappropriate.
A below-transition sample can also form spatially varying domains. Adding a positive gradient term \(K(\nabla P)^2/2\) penalises interfaces, while depolarising fields can favour a mixture with reduced net surface charge. This competition sets new length scales absent from the homogeneous model. An electrode measuring total charge can return near-zero mean polarisation from oppositely oriented domains even though each domain is strongly polarised. A local probe and a bulk capacitance measurement therefore constrain different parts of the model.
Turn a capacitance measurement into a consistency test
For a small harmonic voltage imposed about a prepared local minimum, the differential response is \(\delta P/\delta E=1/[a(T-T_c)+3bP^2]\), provided the driving frequency is slow enough for this local variable to respond and the amplitude is small enough to stay in the same well. Add the vacuum and fast polarisation terms when converting to total displacement \(D\). In a parallel-plate geometry capacitance per area then follows from \(\delta D/\delta E\) divided by thickness.
A large-signal charge–voltage measurement crosses different branches and may dissipate work around a loop. The energy per volume over a closed polarisation cycle is \(\oint E\,dP\) with the sign convention for electrical work. A single equilibrium graph of \(f(P)\) returns to its initial state with no prescribed loop area. Measured hysteresis thus carries dynamical information that a polynomial fit to one reversible branch cannot uniquely reconstruct.
Tutorial
For \(s=-4\) in the scaled model, find zero-field minima and the positive homogeneous spinodal field.
Work through the solution
Zero-field minima lie at \(p=\pm2\). The negative spinodal is
Substitution gives positive field \(16/(3\sqrt3)\simeq3.08\). The \( |s|^{3/2}\) dependence follows from the cubic.
A Newton solver initialised at \(p=0\) reports exact convergence for \(s=-1,e=0\). What additional observation rejects that result as the prepared stable state?
Work through the solution
Its residual is exactly zero but the curvature \(3p^2+s=-1\) is negative. A small perturbation lowers the potential. Check a measured weak-field slope or the relaxation after a perturbation, and compare the energy of the two minima.
Why can the homogeneous coercive field be much larger than the measured coercive field?
Work through the solution
The calculation removes a local barrier only when a spatially uniform state ceases to exist. A real material can switch by creating a small favourable domain and moving a wall; electrodes and defects can lower the needed activation energy. The relevant material and time scales differ.
Compare material descriptions
Use MIT's ferroelectrics and polarisation material to distinguish a microscopic source of displacement from the macroscopic free-energy model used here.
Distinguish magnetic screening from electrical diffusion
Fields and the response of matter
Compare the frequency dependence, phase and thickness dependence of field penetration in a normal metal and a superconducting slab.
Perfect conductivity and magnetic expulsion are different statements
A normal conductor has current density \(\mathbf J=\sigma\mathbf E\). Combining Faraday's and low-frequency Ampère laws in a homogeneous medium gives
A step in field diffuses inwards over a length of order \(\sqrt{t/(\mu\sigma)}\). Under sustained sinusoidal drive the skin depth is \(\delta=\sqrt{2/(\mu\sigma\omega)}\). As \(\omega\) tends to zero, this skin depth tends to infinity. An ordinary nonmagnetic conductor in its final static equilibrium generally admits a uniform applied magnetic field.
The London description of an isotropic superconductor in a Meissner state makes a distinct, equilibrium constitutive assumption:
with penetration length \(\lambda_L\). In a homogeneous specimen carrying supercurrent and at frequencies where displacement current and normal losses may be neglected,
Curl once more and use \(\nabla\cdot\mathbf B=0\). The resulting field satisfies
Unlike the diffusive skin depth, the equilibrium length remains finite for a static applied field.
Taking the formal limit \(\sigma\to\infty\) in a normal conductor suppresses the electric field for a finite current and can freeze a pre-existing flux during changes. That argument does not determine which static field a specimen adopts when cooled through its transition. Magnetic expulsion is extra thermodynamic physics. The comparison below assumes a weak enough field and a suitable state, omitting flux vortices, trapped flux and nonlinear or nonlocal effects.
Solve a slab with equal applied fields on both faces
Let a broad slab fill \(-d/2<x<d/2\), and impose identical tangential magnetic fields \(B_a\hat{\mathbf z}\) on its two faces. Symmetry requires \(B'(0)=0\). Applying both boundaries to the London equation gives
\frac{\overline B}{B_a}=\frac{2\lambda_L}{d}\tanh\frac{d}{2\lambda_L}.
Differentiating gives the screening current \(J_y=-B'_z/\mu_0\). Currents flow in opposite directions at opposite faces; their net transport current across the thickness is zero. For a thick slab each face approaches a half-space with exponential decay. For \(d\ll\lambda_L\), the two surface layers overlap. Expanding the average gives \(1-d^2/(12\lambda_L^2)+\cdots\), so even a superconductor can have a substantial mean internal field in a sufficiently thin specimen under this parallel-field geometry.
Take \(d=100\) nm and \(\lambda_L=50\) nm. The centre field is \(B_a/\cosh 1\simeq0.6481 B_a\); the mean is \(\tanh1\simeq0.7616 B_a\). The distinction between centre value and volume average is already larger than many instrumental error bars. A measurement of magnetic moment in a finite non-slab geometry additionally requires its demagnetising field. Do not directly substitute the infinite-slab mean into an arbitrary sample-shape calibration.
Obtain the equilibrium length as an energy minimum
The same static profile follows from minimising \(\int_{-d/2}^{d/2}[B^2+\lambda_L^2(B')^2]\,dx/(2\mu_0)\) with boundary values imposed. The first term is magnetic field energy; the second is the energy associated with the screening current in this effective description. Vary \(B\) by a function \(\eta\) vanishing at the faces. Integrating \(B'\eta'\) by parts leaves an interior factor \(B-\lambda_L^2B''\). Its vanishing returns the London equation. This route makes the physical tradeoff clear: complete expulsion would require extremely sharp gradients and costly currents, while uniform penetration pays magnetic energy throughout the bulk.
The reduction assumes a fixed superconducting condensate amplitude. Near a critical temperature or critical field, allowing that amplitude to change introduces an additional coherence length and may alter both the field state and the validity of London theory. A numerical fit giving a stable value of \(\lambda_L\) at one temperature does not prove this approximation over an entire phase diagram.
Compare two experimental controls
Change the thickness and the penetration length independently. Find two different specimens with the same \(d/\lambda_L\); their normalised profiles against fractional thickness match, even though their local physical gradients and current densities can differ. If all you can measure is a single normalised profile, geometry calibration is part of the inference of \(\lambda_L\).
A frequency sweep supplies another distinction. In a normal sheet the complex field has both attenuation and phase lag with depth, and \(\delta\) changes as \(f^{-1/2}\). The static London profile above is real and determined by a material length. At higher frequencies superconductors can also exhibit complex response and dissipation, so measuring a single attenuation length in one frequency band cannot by itself establish static flux expulsion. Use the normal-film impedance experiment for a controlled comparison with its different rear boundary condition.
Tutorial
In a thick specimen, how far from one isolated face must a probe be to see 1% of the applied static field? How does the answer depend on field amplitude in this model?
Work through the solution
The half-space profile is \(e^{-x/\lambda_L}\). Set it to 0.01 to obtain
Linearity makes this scaled distance independent of \(B_a\), until the assumed Meissner and weak-field conditions fail.
For a symmetric slab with \(d=4\lambda_L\), compute the centre and mean fractions.
Work through the solution
The centre gives \(1/\cosh2\simeq0.266\). The mean is \(\tanh2/2\simeq0.482\). Both surface layers contribute substantially to the average even when the centre field is much smaller.
A phase-sensitive measurement detects a substantial depth-dependent phase lag in a slowly driven slab. Does the static London solution predict this?
Work through the solution
The static real solution has no phase lag. Assess normal-fluid losses, vortex motion, measurement phase reference and the finite drive frequency. Comparing only magnitudes can conceal these distinct mechanisms.
Read the equilibrium model
The MIT applied-superconductivity course places London's laws alongside microscopic and order-parameter treatments. Use that ordering to identify the assumptions needed when taking a static limit.
Why rotating a layered dielectric changes a capacitance measurement
Fields and the response of matter
Derive the two principal permittivities of a fine laminate, rotate the constitutive tensor and distinguish the applied electrode condition from an assumed field direction.
Compare the same material in two orientations
Build a specimen by repeating layers with scalar permittivities \(\epsilon_1,\epsilon_2>0\), occupying fractions \(f\) and \(1-f\). The period is much smaller than both the specimen scale and the spatial variation of the applied field. Suppose both materials are linear, free of mobile charge and effectively lossless in the measurement band. An observer using a large capacitor wants one law relating averaged displacement and electric field. A scalar average cannot describe both arrangements of the same layers relative to the plates.
Place the field tangential to all internal interfaces first. A narrow rectangular electrostatic loop straddling an interface gives continuity of tangential \(E\). Both layers see the same tangential field, but their displacements differ in proportion to permittivity. Averaging gives
The tangent-direction effective permittivity is an arithmetic mean. This is a parallel connection of capacitances at shared voltage in the special capacitor geometry.
Apply a purely normal displacement instead. No free charge lies at the internal interfaces, so their normal displacement is continuous. Normal fields differ as \(E_i=D_n/\epsilon_i\). Averaging the voltage drops gives
with a harmonic-mean effective permittivity. The local continuity condition changes which field is shared between constituents and thereby changes the relevant averaging operation.
Check the amount of anisotropy from field energy
For \(\epsilon_1=2\epsilon_0,\epsilon_2=10\epsilon_0\) at equal fractions,
The arithmetic-to-harmonic ratio is 1.8. A constituent does not need to be crystalline or anisotropic for the composite to show distinct principal responses. The geometry of the internal boundaries is enough.
Average the energy density for the tangential experiment,
For the normal experiment,
These expressions supply a check independent of the capacitor-circuit analogy and identify which energy should be used when field or free charge is controlled. Energy positivity follows directly from the positive constituent permittivities. It does not require guessing an effective law from the largest measured component.
Rotate the law, then specify what the electrodes control
Use principal axes \(\hat n,\hat t\) and suppose a macro-field makes angle \(\theta\) to the layer normal. If \(\overline{\mathbf E}=E(\cos\theta\,\hat n+\sin\theta\,\hat t)\), then \(\overline{\mathbf D}=E(\epsilon_n\cos\theta\,\hat n+\epsilon_t\sin\theta\,\hat t)\). Project along the imposed field and divide by \(E\):
The perpendicular displacement is \(E(\epsilon_t-\epsilon_n)\sin\theta\cos\theta\). It is generally nonzero. A device that instead fixes the direction of averaged displacement while allowing a transverse field measures \(\epsilon_D(\theta)=[\cos^2\theta/\epsilon_n+\sin^2\theta/\epsilon_t]^{-1}\). These two directional responses correspond to different constraints. They agree at principal axes and for isotropic material. A pair of unspecified “angled capacitor” measurements cannot be interpreted uniquely without describing the contacts and edge conditions.
At 45° in the example, the field-controlled projection gives about \(4.667\epsilon_0\), while the displacement-controlled projection gives \(4.286\epsilon_0\). These are both legitimate scalar ratios from one symmetric positive-definite tensor. Neither supplies a universal scalar permittivity for the rotated material. The complete vector response also predicts displacement tilt and field energy for any orientation.
Test the measurement against the unit-cell model
Change the volume fraction while keeping the constituent values fixed. At a pure phase all orientations and both control conditions must collapse to a single value. At intermediate fractions, find the angle where the transverse component would be largest. It occurs where \(|\sin\theta\cos\theta|\) is largest, but its magnitude also reflects the material contrast. Now reduce the contrast mentally to one and predict all curves without recomputing a single cell.
A numerical field model offers an independent homogenisation experiment. Use periodic tiling in the material directions and impose a macroscopic voltage difference plus periodic fluctuations on opposite faces. For a unit imposed field along each coordinate direction, average the resulting displacement over the cell. The resulting vectors supply the tensor columns. A grounded box on every side is a different boundary problem and can suppress the tangential response. Increase the number of material periods at fixed specimen scale and refine the individual period separately. These two limits test homogenisation and numerical representation, respectively.
How far can the effective law travel?
Electrostatic homogenisation assumes the cell fields respond quasistatically. In a wave experiment near the Bragg gap, phase changes substantially across one period and a local constant tensor is inadequate. A finely layered capacitor and a dielectric mirror can be made from the same constituents while requiring different models at different frequencies. Test the Bloch spectrum to identify the regime where layering begins selecting propagation bands. A low-frequency effective index alone cannot predict that gap.
Large spatial contrast also places a practical demand on mesh and interface handling. A normal gradient can jump strongly even when potential and displacement are continuous. A smooth-looking interpolated voltage surface is weak evidence for an accurate energy density. Compare constituent fields, total flux and energy consistency before accepting the extracted effective tensor.
Tutorial
Show that \(\epsilon_t-\epsilon_n\) is nonnegative for every positive pair of constituents without appealing to a named mean inequality.
Work through the solution
Put both terms over the positive denominator \(f\epsilon_2+(1-f)\epsilon_1\). The numerator after cancellation is \(f(1-f)(\epsilon_1-\epsilon_2)^2\), so the difference is nonnegative and vanishes for identical materials or a pure phase.
Equal fractions give measured relative values 6 tangentially and \(10/3\) normally. Can you infer both constituents if the laminate assumptions hold?
Work through the solution
Their sum is 12. The harmonic mean is \(2ab/(a+b)=10/3\), giving product 20. The positive roots of \(x^2-12x+20=0\) are 2 and 10. The data do not identify which label belongs to which phase without another observation.
Why can a constituent occupy very little volume yet strongly affect the normal response?
Work through the solution
Every normal field line in this lamination crosses each layer. The inverse response weights \(f/\epsilon\); even a thin, low-permittivity layer can contribute a large voltage drop. A field along the layers distributes displacement differently and may be much less sensitive to that same phase.
How a magnetic field rotates the polarisation of transmitted light
Fields and the response of matter
Resolve a linearly polarised wave into circular eigenmodes, infer a refractive-index difference from an analyser and distinguish nonreciprocal rotation from a simple change of reference axes.
Derive rotation from propagation rather than drawing an arrow
Let monochromatic light propagate along \(+z\) through a transparent magneto-optic sample, with an externally prepared axial magnetic field. Define fixed laboratory vectors \(\mathbf e_\pm=(\hat x\pm i\hat y)/\sqrt2\) and use phasors \(e^{i(kz-\omega t)}\). These definitions specify the handedness algebraically. Calling a vector simply “right circular” without stating the viewing and time conventions can reverse a reported rotation sign.
An input linearly polarised in \(x\) is \((\mathbf e_++\mathbf e_-)/\sqrt2\). Suppose the medium supports wave numbers \(k_\pm=2\pi n_\pm/\lambda_0\) for the two bases, with negligible absorption. After a distance \(L\), factor out the common phase \(e^{i(k_++k_-)L/2}\). The remaining Cartesian phasor is \(\hat x\cos\Delta-\hat y\sin\Delta\), where \(\Delta=(k_+-k_-)L/2\). Thus the polarisation angle in the fixed \(x,y\) plane is
Equal transmissions of the two components preserve a linearly polarised output. Unequal absorption makes the circular amplitudes unequal and generally produces an ellipse. Rotating a linear analyser then finds a finite minimum, even for a perfectly coherent field. Residual intensity at the nominal extinction angle can also arise from stray light or imperfect polariser extinction, which must be measured independently.
Derive a magneto-optic eigenbasis
For axial magnetisation, a simple lossless transverse relative-permittivity block is \(\left(\begin{smallmatrix}\epsilon&i g\\-i g&\epsilon\end{smallmatrix}\right)\) with real \(g\) at the frequency of observation. Acting on \((1,i)\) gives \((\epsilon-g)(1,i)\); acting on \((1,-i)\) gives \((\epsilon+g)(1,-i)\). For relative permeability near one, \(n_+^2=\epsilon-g\), \(n_-^2=\epsilon+g\). At small \(g\) their difference \(n_- - n_+\simeq g/\sqrt\epsilon\). Reversing magnetisation reverses the sign of the off-diagonal coefficient and interchanges the two eigenvalues. Both the existence of circular modes and the sign-reversal test now follow from a constitutive model.
If \(n_--n_+\) is proportional to magnetic field over a specified range, write \(\theta=VBL\), with Verdet constant \(V\) in rad/(T m). This is a measurable material and wavelength dependent coefficient. It is not determined by the mean refractive index alone. A strong nearby absorption line can give substantial frequency dependence and dichroism, invalidating a lossless narrow-band extrapolation.
Work through an analyser calibration
For \(\lambda_0=600\) nm, \(L=0.20\) mm and measured index difference \(5.0\times10^{-4}\), the rotation is \(\pi(2.0\times10^{-4})(5.0\times10^{-4})/(6.0\times10^{-7})=\pi/6\), or 30°. An ideal analyser at angle \(\alpha\) transmits \(I/I_\mathrm{in}=\cos^2(\alpha-\theta)\). Its maxima occur at \(30^\circ\) and \(210^\circ\); an intensity measurement determines a linear polarisation angle modulo 180°. For a sample thick enough to rotate several half turns, an intensity maximum alone cannot give an unwrapped \(\theta\). Vary field or path length continuously from a known reference.
If the applied field is independently 0.40 T in that example, \(V=\theta/(BL)\simeq6.54\times10^3\) rad/(T m). The arithmetic is dimensionally correct, but the large value warrants a physical check of thickness, field calibration, units and material spectrum before reporting it as an ordinary glass coefficient. Degrees substituted for radians would make the inferred material coefficient too large by \(180/\pi\).
Use field reversal to reject alignment errors
The experiment shows the predicted analyser traces for opposite index splitting, with the same input polariser. Increase sample thickness to see why tracking the maximum by one measurement can select the wrong branch. Reversing the splitting reverses the tilt in fixed laboratory axes. A fixed analyser offset shifts both inferred angles equally and cancels in half their difference, provided the branch has been unwrapped consistently.
For small rotation, an analyser exactly at a crossed position transmits intensity proportional to \(\theta^2\). Its response has no sign sensitivity close to zero. Set the analyser at 45° instead:
The difference between fields \(+B\) and \(-B\) then measures a signed signal linear in small rotation. This trades extinction of the background for sensitivity to sign. Balance the two orthogonal analyser outputs if source intensity fluctuates appreciably during a sweep.
Ask what happens on a return pass
For the ideal Faraday medium at fixed magnetisation, the circular eigenmodes relative to a fixed laboratory basis are determined by its transverse material tensor. On propagation back through the sample, the accumulated positive propagation path again distinguishes the same laboratory circular basis after accounting for the reflection boundary. With a suitable simple mirror at normal incidence, the resulting material rotation doubles on a round trip in fixed transverse coordinates. In a reciprocal optically active material, the eigenvalue assignment with respect to the laboratory basis reverses on reversing propagation, and the single-pass rotation cancels on the ideal return. Write both transformations in one fixed basis before comparing signs.
A real double-pass setup includes mirror phase shifts, stress birefringence of windows and possible ellipticity. Reversing magnetic field, removing the sample and recording both analyser quadratures provide separate checks. A nonzero rotation in one transmitted beam proves only that its polarisation changed; establishing nonreciprocity requires comparing a reversed propagation experiment with a stated polarisation convention.
Tutorial
Two analyser maxima occur at 47° and 39° for opposite weak fields. If the response is linear and the same branch is tracked, what field-induced rotation and static offset do they imply?
Work through the solution
Half the difference gives 4 degrees of signed rotation for the first field relative to zero. The mean is 43 degrees, the combined input polarisation and analyser zero. Conversion to a Verdet constant additionally needs the applied field and path length.
In the 600 nm example, what thickness uncertainty corresponds to 1 degree of rotation uncertainty at fixed index difference?
Work through the solution
Rotation is proportional to thickness. Relative uncertainty \(1/30\) therefore gives about \(0.20/30=0.0067\) mm, or 6.7 μm. Uncertainty in wavelength or field would add additional contributions.
An ideal analyser gives a minimum 4% of its maximum. Can this be explained solely by a rotation of an ideal linearly polarised monochromatic input in a lossless circularly birefringent sample?
Work through the solution
Pure rotation preserves a linear state, so an ideal analyser should extinguish it completely. Differential loss, ellipticity, depolarisation, finite bandwidth or a detector background are possible alternatives. Use circular-analysis or full Stokes measurements and an empty-path baseline to distinguish them.
Compare with a full polarisation measurement
Use the Stokes reconstruction experiment to determine which intensities reveal a circular component. A fitted linear rotation alone cannot measure that missing component.
Adding angular momentum and predicting which lines can appear
Quantum states, dynamics and measurement
A three-component orbital wavefunction combines with a two-component spin. Derive the allowed total angular momenta, construct their amplitudes explicitly and predict both forbidden transitions and relative strengths in a polarisation-resolved spectrum.
Read the angular momentum algebra as a statement about rotations
Rotate a prepared quantum state through a small angle \(\delta\theta\) about a unit laboratory direction \(\mathbf n\). A continuous norm-preserving transformation has form \(U=I-i\delta\theta\,\mathbf n\cdot\mathbf J/\hbar+O(\delta\theta^2)\), with Hermitian generators \(J_i\). Rotations about different axes need not commute. Comparing the commutator of two infinitesimal rotations with the rotation around the third axis gives
The sum \(J^2=J_x^2+J_y^2+J_z^2\) commutes with each component. One can therefore label eigenstates of \(J^2\) and one chosen component \(J_z\) simultaneously, while generally leaving the other components uncertain.
Define \(J_\pm=J_x\pm iJ_y\). Their commutators with \(J_z\) are \(\pm\hbar J_\pm\); with \(J^2\) they vanish. If \(J_z|m\rangle=\hbar m|m\rangle\), the two ladder operations change \(m\) by one without changing total angular momentum. To determine their coefficients, use \(J_-J_+=J^2-J_z^2-\hbar J_z\) and \(J_+J_-=J^2-J_z^2+\hbar J_z\). Nonnegative squared norms bound the ladder above and below. Let \(j\) be its maximum magnetic quantum number. Vanishing raising norm there fixes the \(J^2\) eigenvalue at \(\hbar^2 j(j+1)\); vanishing lowering norm at the bottom gives
The number of unit steps between the two endpoints is \(2j\), so \(j\) is an integer or half-integer. With a consistent phase convention
Spatial orbital eigenfunctions on an ordinary single-valued scalar wavefunction carry integer orbital \(l\). Spin-\(\tfrac12\) has two states that cannot be modelled by adding another spatial coordinate angle to a scalar orbital. The operator algebra describes both. In \(|j,j\rangle\), \(J_z\) is definite but \(J_x,J_y\) fluctuate. Their variance sum is \(\hbar^2 j(j+1)-\hbar^2j^2=\hbar^2j\); rotational symmetry around \(z\) splits it evenly. Drawing a classical vector with precisely fixed components perpendicular to the axis would miss these fluctuations.
Construct a coupled basis from the stretched state
For independent angular momenta \(\mathbf L,\mathbf S\), the total generator is \(\mathbf J=\mathbf L+\mathbf S\). Operators on different factors commute. In the product basis \(|m_l,m_s\rangle\), \(J_z\) is diagonal with eigenvalue \(\hbar(m_l+m_s)\). The Hamiltonian may instead depend on \(J^2\), for example through \(\mathbf L\cdot\mathbf S\). Then states with the same \(m_l+m_s\) can mix. Resolving that degeneracy requires a unitary change of basis, whose entries are Clebsch–Gordan coefficients.
Take \(l=1,s=1/2\). The unique state \(m=3/2\) is \(|1,\uparrow\rangle\), so it must be \(|3/2,3/2\rangle\). Lower once with \(J_-=L_-+S_-\). The left side is \(\hbar\sqrt3|3/2,1/2\rangle\); the right side is \(\hbar(\sqrt2|0,\uparrow\rangle+|1,\downarrow\rangle)\). Normalising and constructing an orthogonal state in the same \(m\) plane gives
The sign of an entire coupled vector is conventional. The relative sign of its two components matters whenever a later measurement recombines amplitudes. Applying \(J_+\) to the second combination gives zero, which verifies the top of the \(j=1/2\) multiplet independently of orthogonality. Lowering produces four states for \(j=3/2\) and two for \(j=1/2\), exhausting the six-dimensional product space. Merely listing both possible \(j\)'s does not supply the amplitude with which a prepared product state belongs to each, which is what spectroscopy needs.
There is a counting derivation for arbitrary \(j_1,j_2\). Start with one stretched state at \(m=j_1+j_2\) and remove its entire ladder. The next highest unused \(m\) supplies the next multiplet and so on down to \(|j_1-j_2|\). The identity \(\sum_{j=|j_1-j_2|}^{j_1+j_2}(2j+1)=(2j_1+1)(2j_2+1)\) checks completeness. Distinct coupling schemes for three angular momenta are different bases of a common space. An intermediate angular momentum may be a reliable state label when a corresponding interaction dominates, yet cease to be conserved if an external field favours another axis or coupling.
Derive magnetic and parity selection rules
Consider a weak optical field coupled by the electric dipole interaction \(-\mathbf d\cdot\mathbf E\), where \(\mathbf d\) transforms as a vector and has odd parity. Its spherical components relative to \(z\) are
For a definite tensor component \([J_z,d_q]=q\hbar d_q\). Sandwiching the commutator between initial and final \(J_z\) eigenstates yields
Thus nonzero amplitudes require
Coupling \(j_i\) with a rank-one tensor also requires \(|j_i-1|\le j_f\le j_i+1\), and \(0\to0\) is excluded. Parity gives a separate test: under inversion the matrix element gains factor \(-\pi_f\pi_i\), so it vanishes for equal initial and final parity in a parity-symmetric Hamiltonian. For purely orbital motion with parity \((-1)^l\), the triangle condition plus odd parity gives
A direction label on a photon depends on propagation and polarisation conventions. Stating the driven operator component \(q\) is less ambiguous than calling a beam “right circular” without defining the viewing direction.
For a spin-independent dipole transition the spin factor is \(\langle m_s'|m_s\rangle\). Begin in \(l_i=0,m_l=0,m_s=+1/2\) and drive \(q=0\) to \(l_f=1,m_l=0\). In the product basis there is one equally normalised orbital amplitude \(D\). Its projections on the two coupled final levels have squared amplitudes \(2|D|^2/3\) and \(|D|^2/3\), giving a 2:1 line-strength ratio under equal field intensity, comparable detection and negligible population saturation. For \(q=+1\) the product state is \(|1,\uparrow\rangle\). The transition to final \(j=1/2\) vanishes because no \(m=3/2\) belongs to that multiplet. These statements predict relative angular factors. Actual count rates can also depend on frequencies, radial matrix elements, initial populations and how fluorescence is collected.
As an explicit orbital check,
The angular factor of \(d_0\propto r\cos\theta\) is \(\int Y_{10}^*\cos\theta Y_{00}\,d\Omega=1/\sqrt3\), while for \(Y_{1,\pm1}\) the azimuthal integral vanishes. A radial integral can still vanish accidentally even when all angular tests permit the transition. Symmetry rules predict zeros robust to changes preserving that symmetry; a permitted channel has an amplitude that must still be calculated.
Separate atomic structure from analyser orientation with a reduced matrix element
The angular selection rule from the \(J_z\) commutator identifies which transitions are forced to zero but does not alone give their relative strengths. A rotationally covariant way to connect the allowed amplitudes is to view an irreducible tensor component \(T_q^{(k)}\) as carrying angular momentum rank \(k\). Under rotations its \(2k+1\) components transform among themselves with the same representation matrices as the magnetic substates of an angular momentum \(k\). Coupling \(T_q^{(k)}\) to an initial \(|jm\rangle\) therefore furnishes the same product representation as coupling \(|jm\rangle\) to \(|kq\rangle\). The component projecting onto a final \(j'\) must transform as \(j'\). When this representation occurs once in the product, its relative magnetic amplitudes are fixed by Clebsch–Gordan coefficients up to one common factor independent of \(m,q,m'\).
In one standard convention the Wigner–Eckart theorem writes
Additional labels \(\alpha,\alpha'\) specify the radial, spin or configuration information absent from the angular labels. Conventions placing a different square-root factor in the reduced element are equally common, so a table of reduced strengths should be checked before combining it with an external coefficient table. The theorem predicts ratios within a fixed \(j,j'\) multiplet. It does not remove differences in radial integrals between unrelated configurations, nor does it assert the reduced element is nonzero. This factorisation explains why angular data alone may fix a branching ratio while offering no absolute radiative lifetime.
For a vector operator connecting \(j\) to the same \(j\), there is an especially transparent example. Within a given irreducible \(j\) space, any vector operator has matrix elements proportional to the corresponding \(J_q\) matrix elements, provided additional degeneracies are separated. For the conventional spherical components \(J_0=J_z\), \(J_{+1}=-J_+/\sqrt2\), ask for the ratio of line strengths out of \(j=2,m=1\) into \(m'=2\) via \(q=+1\) and into \(m'=1\) via \(q=0\), with equal field amplitudes in the specified components. The squared matrix elements of \(J_q\) are \(\hbar^2[6-1(2)]/2=2\hbar^2\) and \(\hbar^2\), hence the ratio is two. The same numerical angular ratio can apply to any appropriate nonzero reduced vector coupling between these specified manifolds. For an electric dipole transition parity must still allow the initial and final configurations; using \(J_q\) here computes angular ratios and does not turn angular momentum itself into an electric dipole operator.
Summing over a complete set of final magnetic substates and all tensor components supplies a useful normalisation audit. For a fixed initial \(m\), rotational invariance of the scalar sum \(\sum_q T_q^\dagger P_{j'}T_q\) makes its diagonal expectation independent of \(m\). A detector with a preferred polarisation or direction samples only a subset and may exhibit strong dependence on \(m\). This difference is essential in interpreting “unpolarised” line strengths: an unpolarised pump that populates all \(m\) equally, an unanalysed detector that sums final polarisations, and a source with a definite \(m\) viewed along one axis are three different experimental ensembles.
Compare successive Stern–Gerlach measurements with addition of spin
Two spin-\(1/2\) particles provide a minimal addition experiment with no spatial angular wavefunction needed. The coupled triplet basis is \(|1,1\rangle=|\uparrow\uparrow\rangle\),
the singlet is \((|\uparrow\downarrow\rangle-|\downarrow\uparrow\rangle)/\sqrt2\). An apparatus measuring the total \(z\) component alone cannot distinguish the two \(m=0\) states. Measuring \(J^2\) along with \(J_z\) can. Their local one-spin reduced matrices are both \(I/2\), so even complete tomography of either spin alone fails to reveal the difference. The distinction lies in a joint correlation.
The singlet projector can be obtained as a polynomial in \(\mathbf S_1\cdot\mathbf S_2\). That scalar has eigenvalues \(-3\hbar^2/4,+\hbar^2/4\), so \(P_s=I/4-\mathbf S_1\cdot\mathbf S_2/\hbar^2\). Expressing \(\mathbf S_i=(\hbar/2)\boldsymbol\sigma_i\) gives
If three independently prepared ensembles yield measured same-axis correlations \((-0.80,-0.78,-0.82)\), their inferred singlet fraction is
This result uses all three axes. Perfect \(z\)-anticorrelation alone constrains the population to a two-dimensional \(m=0\) space but says nothing about the relative phase within it. If each measurement has uncertainty 0.03 and the estimates are independent, the resulting statistical uncertainty in singlet fraction is \(\sqrt3(0.03)/4=0.013\), before calibration uncertainties.
For a coherent initial product \(|\uparrow\downarrow\rangle\), a Hamiltonian \(H=J_{\rm ex}\mathbf S_1\cdot\mathbf S_2/\hbar^2\) evolves the singlet and triplet amplitudes with distinct phases. Writing the initial state as \((|1,0\rangle+|0,0\rangle)/\sqrt2\), the probability to find spins reversed later is \(\sin^2(J_{\rm ex}t/(2\hbar))\). The total \(m\) remains exactly zero at all times. If \(J_{\rm ex}/h=5.00\) MHz, the first full reversal occurs at \(t=1/(2\times5\,\mathrm{MHz})=100\) ns. An incoherent mixture with the same singlet and triplet populations has a constant reversal probability one half. This calculation makes the signs in the coupled basis observable and distinguishes a true exchange evolution from random spin flips inferred solely from individual populations.
Rotate the quantisation axis without changing the atomic Hamiltonian
A transverse magnetic or polarisation analyser can interrogate a state prepared relative to \(z\) along a different laboratory axis. For spin \(1/2\), \(e^{-i\theta S_y/\hbar}=\cos(\theta/2)I-i\sin(\theta/2)\sigma_y\), from \(\sigma_y^2=I\). To obtain the rotation probabilities for a spin-one state without memorising a rotation matrix, represent its stretched state as the symmetric product of two up spinors. Under a common rotation each spinor transforms as \(\cos(\theta/2)|\uparrow\rangle+\sin(\theta/2)|\downarrow\rangle\). Expanding the two-spin product gives the triplet amplitudes \(\cos^2(\theta/2),\sqrt2\cos(\theta/2)\sin(\theta/2),\sin^2(\theta/2)\) for the three \(m\) values. This construction exploits the representation and applies to any angular momentum one, regardless of its microscopic origin.
At \(\theta=\pi/2\), a stretched \(m=1\) state projected on the rotated axis gives probabilities \((1/4,1/2,1/4)\). The expectation of its rotated component vanishes, but outcomes \(+\hbar\) and \(-\hbar\) still occur and the variance is \(\hbar^2/2\). A source prepared in \(m=0\) along \(z\) gives a different test. Rotate its symmetrised up–down form on both spins and project on \(m=0\); the amplitude is \(\cos\theta\) and the probability \(\cos^2\theta\). At a right angle the “zero” outcome is absent, although the mean along either axis is zero. A single mean value cannot distinguish alignment from an unpolarised mixture. Measuring the full resolved substate distribution, or its quadrupole moment, can.
The general stretched state \(|j,j\rangle\) can be represented by \(2j\) symmetrised spinors all up. Its rotated \(m\) outcome distribution is binomial:
Its mean angular momentum component is \(\hbar j\cos\theta\), with variance \(\hbar^2(j/2)\sin^2\theta\). At fixed nonzero \(\cos\theta\), the relative fluctuation falls like \(j^{-1/2}\) as \(j\) grows. This supplies a precise sense in which a large stretched state can approximate a classical oriented angular momentum while retaining quantum projection noise. A state with the same large \(j\) but \(m=0\) need not resemble an oriented classical arrow. The representation dimension alone does not determine the suitability of a classical approximation.
Distinguish an angularly forbidden line from coherent cancellation
Suppose two degenerate lower magnetic states \(|g_1\rangle,|g_2\rangle\) both couple to one excited state \(|e\rangle\) under controlled coherent drives. In a rotating-frame model the raising part is \(|e\rangle(\Omega_1\langle g_1|+\Omega_2\langle g_2|)\hbar/2\), with the lowering term its adjoint. A normalised superposition proportional to \(\Omega_2|g_1\rangle-\Omega_1|g_2\rangle\) has zero excitation amplitude because the two terms cancel. Each angular channel can be individually allowed and strong, yet this particular coherent combination is dark. Its orthogonal bright state is proportional to \(\Omega_1^*|g_1\rangle+\Omega_2^*|g_2\rangle\) and has effective Rabi coupling \(\sqrt{|\Omega_1|^2+|\Omega_2|^2}\).
For equal real drives and an initially balanced antisymmetric superposition, the transition ideally vanishes. A randomly prepared mixture of the same two basis states populates the bright and dark subspaces equally. If a resonant pulse transfers the bright component completely, that mixture produces 50% excitation. Changing the relative optical phase changes which superposition is dark but does not change the selection rule for either individual transition. Preparing a calibrated ground-state phase and scanning the drive phase can therefore distinguish coherent cancellation from a forbidden angular matrix element or a disconnected drive channel. Two-photon detuning, magnetic splitting of the lower states and dephasing can spoil the destructive interference even if every angular coefficient is exactly known.
Track a spin while rotating the preparation axis
Change the path of a spin direction and compare a change in its geometric phase with an ordinary dynamical phase.
Predict which perturbation can make a dark transition visible
Electric dipole selection rules use the approximation that the driving field is essentially uniform across the atom. Expand a monochromatic plane wave \(e^{i\mathbf k\cdot\mathbf r}=1+i\mathbf k\cdot\mathbf r+\cdots\). For a source of size \(a\) the next spatial term is suppressed in amplitude by a factor of order \(ka\) when \(ka\ll1\). Consistently expanding the light–matter Hamiltonian yields higher electric multipoles and magnetic couplings with their own symmetry. The electric quadrupole is a rank-two even-parity tensor. Thus it can connect same-parity states with \(|j_i-2|\le j_f\le j_i+2\). A magnetic dipole is a rank-one operator of even spatial parity, permitting some same-parity transitions denied to an electric dipole. A line forbidden to one specified multipole need not vanish in all experimental conditions.
Take a model atom with a lower \(j=0\) even state and an upper \(j=2\) even state. Electric dipole fails both parity and angular-momentum tests. Magnetic dipole has the right parity but still cannot supply total angular rank two. Electric quadrupole has the correct parity and satisfies the triangle condition; its actual reduced matrix element and the applied field gradient still determine strength. In a \(j=0\to j'=2\) transition with \(m_i=0\), each spherical quadrupole component \(q\) excites only \(m_f=q\). A simple claim that changing circular to linear polarisation opens an electric dipole line in this field-free atom would be inconsistent with both global selection rules. A static field that mixes opposite parity or different angular momentum can change the states themselves and thereby modify that conclusion.
For a 600 nm wavelength and characteristic radius \(a=0.10\) nm,
The squared geometric factor is about \(1.1\times10^{-6}\) relative to a typical allowed electric dipole strength in comparable units, before distinct radial and angular factors. This is an order estimate, not a quantitative branching ratio for two arbitrary lines. In particular, dividing a finite quadrupole amplitude by a strictly zero dipole amplitude of the same ideal transition is meaningless. Compare with a separate reference line whose dipole matrix element and detection efficiencies are known if a rate ratio is needed.
An independent way to brighten an otherwise forbidden line is mixing through a perturbation \(W\). Suppose an upper state \(|u\rangle\) has zero electric dipole amplitude from \(|g\rangle\), while a nearby state \(|v\rangle\) allows amplitude \(D\). If \(|\langle v|W|u\rangle|\ll|E_u-E_v|\), the perturbed upper state contains coefficient \(\epsilon=\langle v|W|u\rangle/(E_u-E_v)\) of \(|v\rangle\), and its borrowed dipole intensity scales as \(|\epsilon|^2|D|^2\). Where \(W\) is proportional to a reversible static field, borrowed intensity typically begins quadratically in that field for a previously dark isolated line. A native higher-multipole contribution may already be present at zero field and can interfere if it feeds the same final channel with coherent angular dependence.
Use polarisation and bias sweeps to identify borrowed intensity
In a two-state model the bright level is 2.00 GHz away and a perturbation mixes it with the dark state at off-diagonal \(W/h=20\) MHz. Predict relative borrowed intensity, assess the leading approximation, and identify an independent spectroscopic consequence.
Derive and check the result
The small parameter is
The leading borrowed intensity is \(10^{-4}\) of the corresponding bright reference, with corrections of relative order \(10^{-4}\) in the ideal two-level mixing expansion. The dark state's energy shifts by approximately \(W^2/(E_u-E_v)\), whose magnitude expressed as ordinary frequency is
Its sign is away from the neighbouring bright level. Measuring this level repulsion together with the same polarisation pattern as the borrowed bright transition tests the mixing explanation. Changing the perturbing field by a factor of two should increase both the leading borrowed intensity and the magnitude of the second-order level shift by a factor of four while the coupling remains weak. A field-independent residual or a different polarisation dependence motivates examining other multipoles or additional states.
Tutorial · infer the state that a spectrum actually selects
Measure the orbital label after total angular momentum preparation
Prepare \(|j=1/2,m=1/2\rangle\) in the coupled \(p\) manifold. Predict \(m_l\) outcomes, the spin expectation and the sum \(\langle L_z+S_z\rangle\). Is either product component a state with definite \(J^2\)?
Work through the solution
The probabilities are \(1/3\) for \(m_l=0\) with spin up, \(2/3\) for \(m_l=1\) with spin down. Thus \(\langle L_z\rangle=2\hbar/3\), \(\langle S_z\rangle=-\hbar/6\) and the sum is \(\hbar/2\). The product vectors in this two-dimensional plane are each superpositions of both \(j\)'s, as can be checked by inverting the two orthogonal combinations. A joint measurement of orbital and spin labels can therefore disturb a previously exact \(J^2\). The total \(m\) remains fixed in every outcome, stronger than merely having the correct mean.
Determine a spin–orbit interval without an angular integral
Within \(l=1,s=1/2\), take \(H'=A\,\mathbf L\cdot\mathbf S/\hbar^2\) with \(A/h=8\) GHz. Find level shifts, degeneracies and their degeneracy-weighted centre. Check the result from a product-basis trace.
Work through the solution
Use \(2\mathbf L\cdot\mathbf S=J^2-L^2-S^2\). For \(j=3/2\) the factor is \(+1/2\); for \(j=1/2\) it is \(-1\). Shifts are \(+4\) and \(-8\) GHz, with degeneracies four and two; their interval is 12 GHz and their weighted centre is zero. The product-basis trace of each \(L_iS_i\) is \(\operatorname{tr}L_i\,\operatorname{tr}S_i=0\), which predicts that centre independently. If a measured centroid is weighted by optical intensity instead of counting every substate once, it need not equal this trace centre.
Distinguish resolved lines from a coherent pulse
A short \(q=0\) pulse prepares the product final state \(|0,\uparrow\rangle\) above. If its spectrum covers both \(j\) levels coherently, find the later return probability to that same product state for a level angular-frequency splitting \(\Delta\). What would an incoherent population mixture give?
Work through the solution
The return amplitude is \((2/3)e^{-iE_{3/2}t/\hbar}+(1/3)e^{-iE_{1/2}t/\hbar}\). Its squared modulus is \(5/9+(4/9)\cos\Delta t\), between \(1/9\) and 1. The corresponding incoherent mixture gives a constant \(5/9\). At \(t=0\) both constructions share the same energy-measurement probabilities, yet only the coherent preparation returns with certainty to the original product state. Temporal resolution, controlled pulse phase and bandwidth sufficient to cover both lines are part of the proposal. If the emitted or absorbed field records distinguishable frequencies, the observed beat can be suppressed.
Further reading
When a magnetic field changes the quantum numbers of an atom
Quantum states, dynamics and measurement
Weak-field Zeeman slopes label total-angular-momentum multiplets. At stronger fields those slopes curve and intensities migrate. Solve an entire orbital-plus-spin manifold and infer coupling constants from measurable line positions and polarisation.
Choose the Hamiltonian appropriate to a resolved orbital manifold
Suppose an isolated atomic \(p\) manifold with \(l=1,s=1/2\) is sufficiently far from other orbital or principal levels to treat only its six substates. Take \(z\) along a uniform external magnetic field \(B\). Work to first order in the electronic Zeeman operator and model spin–orbit coupling by the constant \(A>0\). With \(b=\mu_B B\) and electron spin factor approximated by two,
Both \(A\) and \(b\) are energies. The sign of the second term is positive for the electron because magnetic moment is opposite to angular momentum and field energy is minus moment dot field. Here \(\mu_B=e\hbar/(2m_e)>0\). The orbital manifold approximation requires magnetic splittings small compared with gaps to omitted levels. Neglected terms can include the difference of the actual spin factor from two, hyperfine interactions and the diamagnetic \(B^2\) term. An “intermediate field” in this discussion means \(b\) comparable to \(A\); it need not exceed any other electronic binding scale.
At zero field the coupled levels \(j=1/2,3/2\) have energies \(-A,+A/2\). At nonzero field the projection \(m=m_l+m_s\) is still conserved because \([H,J_z]=0\). For intermediate fields \(J^2\) need not commute with the Zeeman term. Consequently the six-state problem reduces to two one-dimensional and two two-dimensional invariant blocks, even when the label \(j\) loses its exact meaning. Following a state by magnetic quantum number and overlap with a neighbouring field value is generally more reliable than sorting all computed energies from low to high. Crossings of different \(m\) can reorder a sorted list without exchanging the underlying states.
Derive the Landé slope from angular momentum projection
In a state with definite \(j,l,s,m\), expectation of any vector operator proportional in direction to \(\mathbf J\) within its irreducible multiplet can be obtained from its scalar projection on \(\mathbf J\). For spin,
One way to obtain the projection numerator is \(2\mathbf S\cdot\mathbf J=J^2+S^2-L^2\). Since \(L_z+2S_z=J_z+S_z\), the energy slope for weak fields is \(dE/db=g_jm\) with \(g_j=1+[j(j+1)+s(s+1)-l(l+1)]/[2j(j+1)]\). A state \(j=0\) has vanishing linear vector moment and should be treated separately instead of dividing by zero. Within the \(p\) manifold the \(j=1/2\) factor is \(2/3\) and the \(j=3/2\) factor \(4/3\). For \(m=+1/2\) these correspond to slopes \(1/3\) and \(2/3\) in energy units of \(b\). Their sum is exactly one, a trace constraint that remains valid for the sum of the two eigenvalues in that block at every field.
If \(A/h=8.00\) GHz as in the previous angular exercise, the zero-field interval is 12.00 GHz. At \(B=20.0\) mT, \(b/h\simeq0.280\) GHz using \(\mu_B/h=13.996\) GHz/T. The two positive-\(m\) shifts to linear order are \(+0.0933\) and \(+0.1866\) GHz. Actual optical frequencies measure final minus initial energies; an initial \(s_{1/2}\) level has its own Zeeman slope. Omitting it is a common reason a slope inferred from a line scan seems inconsistent with the expected Landé factor.
Diagonalise the mixed levels across the entire crossover
In the \(m=+1/2\) product basis \((|0,\uparrow\rangle,|1,\downarrow\rangle)\), expand \(\mathbf L\cdot\mathbf S=L_zS_z+(L_+S_-+L_-S_+)/2\). The diagonal spin–orbit elements are \(0,-A/2\); the off-diagonal element is \(A/\sqrt2\). The Zeeman term is diagonal with entries \(b,0\). Hence
At \(b=0\) the square root is \(3A/2\), recovering the coupled levels. For the \(m=-1/2\) basis \((|0,\downarrow\rangle,|-1,\uparrow\rangle)\), replace \(b\) by \(-b\). The stretched levels \(|1,\uparrow\rangle\) and \(|-1,\downarrow\rangle\) remain product states at every field with energies \(A/2\pm2b\). Counting all levels and their traces provides an independent check: spin–orbit and Zeeman each have zero trace in the full six-dimensional space. At zero field both slopes in the \(+\) block are finite and positive. At large positive \(b\) the upper slope tends to one and the lower to zero, approaching their uncoupled product labels.
In the negative-\(m\) block the two uncoupled energies would cross at \(b=A/2\). The coupling opens a minimum gap \(\sqrt2A\). Within the model, levels of the same \(m\) avoid one another whenever this matrix element is nonzero. Crossings between different \(m\) can remain exact because the uniform \(z\)-directed Hamiltonian does not mix them. A tilted perturbation could turn some of these into avoided crossings. Such symmetry dependence matters when trying to infer a coupling from the smallest visible distance between any two lines.
Obtain an eigenvector weight from an energy derivative
Suppose an initial \(s\) state has spin up. A weak \(q=0\) electric-dipole drive prepares the product basis state \(|0,\uparrow\rangle\) in the \(m=+1/2\) block. Its squared overlap with an exact eigenstate determines the angular part of that optical line's strength. Rather than computing a mixing angle with a branch ambiguity, differentiate the exact energies. Since \(\partial H_+/\partial b=|0,\uparrow\rangle\langle0,\uparrow|\), the eigenvalue derivative equals precisely that population:
The weights sum to one as required by completeness. At zero field they are \(2/3\) and \(1/3\). At large positive field the upper line takes almost all this polarisation strength. In the negative block an analogous derivative with respect to \(-b\) gives the population of \(|0,\downarrow\rangle\). At its avoided crossing each eigenstate has equal weights and the two corresponding \(q=0\) intensities are equal for a selected initial spin down. The same experiment can test slopes measured from frequencies and overlaps measured through intensities, provided detection and radial coupling are common to both lines.
Set \(b=A\) in the positive block. The level separation becomes \(A\sqrt{4.25}=2.06155A\), while the upper product weight is \(0.8638\). A naive extrapolation of the weak-field \(g_jm\) slopes would give an interval \(1.5A+A/3=1.833A\). The discrepancy is governed by the spin–orbit mixing scale rather than failure of the magnetic Hamiltonian itself. If the frequency analyser resolves only a single intensity-weighted centroid, completeness still constrains the first moment:
Thus the centroid of unresolved lines in this ideal selected excitation can move linearly even while each constituent bends.
Resolve a second angular-momentum hierarchy with the same algebra
The \(p\)-manifold example coupled orbital and electronic spin. In an \(s\)-state atom the dominant remaining weak angular coupling may be between an electronic \(J=1/2\) and a nuclear \(I=1/2\). This is a different scale and a different physical pair of degrees of freedom. To illustrate how a state label changes with field, take
with positive hyperfine constant \(A_h\) and a positive model nuclear \(g_I\). The minus before the nuclear-magneton term reflects the assumed positive nuclear magnetic moment. Actual sign and \(g\)-factor depend on the isotope. Here both \(A_h\) and the products of magnetic moments and field have energy units. At zero field the electronic and nuclear angular momenta combine to \(F=0,1\). Their scalar-product shifts are \(-3A_h/4\) and \(+A_h/4\), respectively. A rotation of the entire coupled system leaves this zero-field Hamiltonian invariant, but independent rotations of just one constituent generally do not.
Within \(m_F=0\) order the product basis by electronic magnetic sign as \(|\uparrow_J,\downarrow_I\rangle,|\downarrow_J,\uparrow_I\rangle\). Both diagonal hyperfine matrix elements are \(-A_h/4\), off-diagonal exchange is \(A_h/2\), and field changes the diagonal difference by \(\delta=(g_J\mu_B+g_I\mu_N)B\). Hence the central pair of energies is
The two stretched \(m_F=\pm1\) levels sit at \(+A_h/4\pm(g_J\mu_B-g_I\mu_N)B/2\). Their slopes contain a difference of electronic and nuclear moments, while the central splitting depends on their sum. This sign distinction can be determined directly by comparing the relevant product states: in the anti-aligned pair the sign change reverses one angular momentum along with its opposite magnetic sign. A sign convention imported from electron spin alone would give an erroneous nuclear contribution.
The transition between the two central states has gap \(\sqrt{A_h^2+\delta^2}\) and zero linear slope at \(B=0\). Its quadratic shift is \(\delta^2/(2A_h)\) for \(|\delta|\ll A_h\). Measuring at a point with zero first derivative reduces sensitivity to slow field fluctuations without eliminating it. Suppose \(A_h/h=1.00\) GHz and \((g_J\mu_B+g_I\mu_N)/h=28.0\) GHz/T in an illustrative species model. At a 1.0 mT bias the central gap rises by about 0.392 MHz. A 1 μT field error at that bias gives a first-order frequency error of about 784 Hz using the derivative of the quadratic expansion. At zero mean bias, fluctuations with rms 1 μT instead give an average quadratic shift about 0.392 Hz. Stabilising the field mean and reducing its variance address different terms in the measured spectral position.
The magnetic drive operator for a small oscillating field along \(z\) is itself proportional in this block to \(\sigma_z\). At zero bias the hyperfine eigenstates are the symmetric and antisymmetric superpositions, so this drive couples them off-diagonally despite the central transition frequency being stationary against a small static bias. The diagonal derivative and the off-diagonal transition matrix element are distinct quantities. At large bias the eigenstates approach product states and the same longitudinal drive becomes mostly diagonal, reducing its ability to flip between them. Thus a transition can have both a vanishing first-order shift and a nonzero resonant driving strength, consistent with the same Hamiltonian. Measuring both properties probes the field dependence of eigenvectors as well as eigenvalues.
Infer a field distribution from widths and centres
Spectra of spatially extended samples often contain a distribution of static magnetic fields. Consider a single weak-field transition with frequency \(\nu(B)=\nu_0+sB\), an intrinsic Gaussian line standard deviation \(w_0\), and a sample field distributed approximately Gaussian with mean \(B_0\) and standard deviation \(\sigma_B\). A sum over independent source regions convolves the intrinsic line with the frequency distribution generated by \(sB\). The observed centre is \(\nu_0+sB_0\), and variance is \(w_0^2+s^2\sigma_B^2\). A single linewidth cannot determine both an intrinsic width and a field inhomogeneity. Two lines with different known magnetic slopes or one calibrated zero-slope reference can separate the contributions.
For example two transitions with slopes 7.0 and 14.0 GHz/T have measured standard deviations 0.250 and 0.400 MHz. Subtract the squared widths to eliminate \(w_0^2\):
using MHz/T in the denominator. The result is \(\sigma_B=25.8\,\mu\mathrm T\), and the inferred intrinsic width is
A third line with slope near zero supplies an out-of-sample check. If lines have significantly different lifetimes or power broadening, the assumption of a common \(w_0\) should be relaxed; otherwise one can spuriously infer a magnetic gradient or even a negative intrinsic variance.
For a curved avoided-crossing line expand \(\nu(B)\simeq\nu(B_0)+s(B-B_0)+q(B-B_0)^2/2\). A symmetric distribution shifts the measured mean by \(q\sigma_B^2/2\) even when the mean field is known exactly. Near a stationary point the leading field broadening can be strongly asymmetric because a squared Gaussian variable has a one-sided distribution around its minimum. Fitting a symmetric line at such a point can shift its apparent peak or centre according to the fitting convention. This effect is especially relevant when locating a minimum gap from spectra at several nominal fields. A model integrating intensities over a measured spatial field distribution can be better constrained than independent fits of Gaussian centres, because all lines share the same underlying field profile.
An independent geometric test tilts the weak sensing light relative to the magnetic axis. For equal populations, a truly scalar average over all polarisations and emitted directions is insensitive to this coordinate change, but a selected \(q\) transition changes strength according to the decomposition of the laboratory polarisation. If a peak attributed to frequency splitting mainly changes its fitted centre while unresolved component intensities redistribute, some of its apparent shift may be an intensity-weighted centroid effect. Record spectra at two orthogonal polarisations, fit the same physical energy parameters and allow the predicted angular strengths to vary. A common energy correction that survives the intensity change carries a different interpretation from a change in the mixture of unresolved substates.
Predict state transfer during a field sweep
The negative-\(m\) avoided crossing of the \(p\) manifold also poses a time-dependent question. Does a changing field keep the atom in the instantaneous energy eigenstate, or in approximately the same product state? In the local two-state description subtract the trace and write \(H=(\Delta(t)/2)\sigma_z+g\sigma_x\), where the difference of diabatic diagonal energies is \(\Delta\) and the minimal adiabatic gap is \(2|g|\). Introduce a mixing angle \(\tan(2\vartheta)=2g/\Delta\), chosen continuously through the crossing. Differentiating at fixed \(g\) gives
The moving eigenbasis itself couples the two instantaneous energy states with an energy scale \(\hbar|\dot\vartheta|\).
At closest approach the order-of-magnitude adiabatic criterion becomes \(\hbar|\dot\Delta|/(8g^2)\ll1\). A slow sweep keeps occupation on an energy branch, which changes its product character across the avoided crossing. A fast sweep can leave the original product state approximately unchanged, moving population from one instantaneous energy branch to the other. Both descriptions refer to actual state transfer; the basis in which “remaining in the same state” is assessed is part of the observable. The criterion here follows directly by comparing the nonadiabatic derivative coupling with the instantaneous level separation. It estimates a regime but does not by itself give a transition probability.
For a strictly linear detuning passing from large negative to large positive values with constant \(g\), the Landau–Zener result gives the diabatic survival probability \(P_D=\exp[-2\pi g^2/(\hbar|\dot\Delta|)]\). Its applicability requires asymptotic start and end detunings well outside the coupling region, coherent passage and the indicated linearity over the crossing. In ordinary-frequency units take \(g/h=20\) kHz and \(|d(\Delta/h)/dt|=1.0\times10^{10}\ \mathrm{Hz/s}\). The exponent is \(4\pi^2(2.0\times10^4)^2/10^{10}=1.58\), giving \(P_D\simeq0.206\). Doubling the sweep rate halves the exponent and raises survival to about 0.454. Confusing angular with ordinary frequency in this conversion loses a factor \(2\pi\), large enough to change the predicted population qualitatively.
A double sweep forms a useful control. On entering and later leaving the avoided crossing, the two amplitudes propagated along different energy branches can accumulate different phases and interfere. Treating the two passages as independent classical jumps would miss oscillations versus waiting time between them. Strong dephasing or averaging over a broad field distribution can remove the oscillations while retaining the one-pass populations. Distinguish these mechanisms by calibrating single-passage transfer first and then varying the waiting time over several periods at multiple sweep speeds. This extends a static magnetospectroscopy model to a specified dynamical experiment without inferring the full time dependence from a static level diagram alone.
Resolve the crossover from coupled to uncoupled angular momenta
Scan the magnetic field across the spin–orbit scale. Compare the exact two-state spectrum at fixed magnetic quantum number with the weak-field shifts.
Test the orientation of a magnetic sensor from resolved spin populations
The scalar energy spectrum of an isotropic spin-\(1/2\) Zeeman Hamiltonian measures field magnitude. A transition energy by itself cannot determine the signed orientation of that field. Let \(H=\hbar\gamma\mathbf B\cdot\boldsymbol\sigma/2\), with signed angular gyromagnetic ratio \(\gamma\) defined in the experiment. Its eigenvalues are \(\pm\hbar|\gamma||\mathbf B|/2\). If instead one prepares spin up along a known laboratory \(z\) direction and observes its population after evolution time \(t\), the rotation axis appears in the dynamics. Exponentiating \(U=\cos(\omega t/2)I-i\sin(\omega t/2)\hat{\mathbf B}\cdot\boldsymbol\sigma\) for a consistent choice of \(\omega,\hat{\mathbf B}\) gives
The oscillation frequency gives magnitude and its contrast gives the squared transverse fraction. It is insensitive to whether the field points slightly above or below a perpendicular plane. Incomplete preparation or pulse contrast can also reduce the observed oscillation amplitude. A calibration with a known transverse field tests that ambiguity before assigning every missing contrast to geometric tilt.
Suppose a resolved precession has angular frequency corresponding to 0.50 mT and a calibrated flip contrast of 0.36 for initial \(+z\). Then \(\sqrt{B_x^2+B_y^2}=0.30\) mT and \(|B_z|=0.40\) mT. Repeating for an initial \(+x\) state with calibrated contrast 0.64 yields \(|B_x|=0.30\) mT and thus \(B_y=0\) for these numbers. Neither experiment identifies the signs of \(B_x\) and \(B_z\). To resolve them one can measure an early-time transverse quadrature with a phase reference. In Bloch notation \(\dot{\mathbf r}=\gamma\mathbf B\times\mathbf r\), so the initially zero slope \(\dot r_y=-\gamma B_x\) for \(+z\) is sign sensitive. This derivative is independent of \(B_z\) at the initial instant, giving a direct check complementary to the energy splitting.
A second strategy adds a calibrated bias \(\mathbf b_0\) in opposite directions and examines squared frequencies. Since \(|\mathbf B+\mathbf b_0|^2-|\mathbf B-\mathbf b_0|^2=4\mathbf B\cdot\mathbf b_0\), the difference isolates a signed projection even when the zero-field splitting reveals only magnitude. For a 0.20 mT known bias along \(z\) and a 0.40 mT signed \(z\) component the squared-field difference should be \(0.32\,\mathrm{mT}^2\). Alternating the two bias signs across the measurement reduces slow field drift. A quadratic diamagnetic response, anisotropic \(g\) tensor or an uncalibrated bias axis can break this simple inversion; repeating in three independent directions tests the vector model and reveals which assumptions are being used.
Separate an anisotropic magnetic response from an unknown field direction
A crystal-fixed effective spin has diagonal \(g=\operatorname{diag}(2.0,2.0,2.4)\). Derive the transition energy for a field rotated in the \(x,z\) plane by angle \(\theta\) from \(z\), and explain what an isotropic fit would infer.
Derive and check the result
The Hamiltonian is \(\mu_B\boldsymbol\sigma\cdot(g\mathbf B)/2\). The splitting is \(\mu_B B\sqrt{2.0^2\sin^2\theta+2.4^2\cos^2\theta}\). At \(45^\circ\) the effective \(g\) is \(\sqrt{4.88}=2.209\); interpreting the measured splitting with constant \(g=2\) would overestimate field magnitude by about 10.5%. The spin also precesses around the effective axis \(g\mathbf B\), whose polar angle satisfies
Measuring contrast from a calibrated spin preparation and rotating a field of known magnitude can therefore distinguish material anisotropy from a simple error in magnet alignment. One scalar spectral line at an unknown orientation cannot separate these effects.
Tutorial · reconstruct a magnetically mixed spectrum
Infer the coupling from an anticrossing
The two negative-\(m\) lines exhibit a minimum frequency separation of 11.31 GHz at 0.286 T. Infer \(A/h\) from each measurement. What calibration would be needed for a comparison of absolute optical line frequencies?
Work through the solution
Minimum gap divided by \(h\) equals \(\sqrt2 A/h\), giving \(A/h=8.00\) GHz. The crossing condition \(b=A/2\) gives
Their agreement checks field calibration independently of a common frequency reference. Both final states must be viewed from the same initial state when using their frequency difference. Comparing absolute optical frequencies also requires the zero-field transition energy and the field-dependent initial-level shift. Two lines originating in different initial states would have a field-dependent separation even if their final levels had a fixed interval.
Extract the polarisation weight using a finite difference
Near \(b=A\), estimate the slope of the upper positive-\(m\) level using its exact values at \(b/A=0.95,1.05\). Compare with the exact weight and predict the second line's strength.
Work through the solution
In units of \(A\) the upper level is \((t-0.5+\sqrt{(t+0.5)^2+2})/2\) with \(t=b/A\). Subtracting the values and dividing by 0.10 gives about 0.864. The analytical derivative is
The second line carries 0.1362 of the total angular strength. Halving the centred step should reduce the derivative's truncation error by about four for this smooth curve. In an experiment frequency noise per point is instead amplified as inverse step. Compare several field steps to establish a practical slope uncertainty.
Use an unresolved centroid to detect a calibration problem
At \(b=A\) a weak \(q=0\) experiment driven from a selected spin-up preparation records both positive-\(m\) final states. Its excitation-weighted centroid after restoring the initial-state energy is \(0.78A\). Could the exact two-level mixing alone produce that centroid?
Work through the solution
The sum rule requires \(b=A\). Direct calculation gives energies approximately \(1.2808A\) and \(-0.7808A\); weights 0.8638 and 0.1362 give \(1.000A\) within rounding. In this model mixing alone cannot explain \(0.78A\). A missing weak line, saturation, polarisation contamination, different collected fluorescence efficiencies or a mistaken correction for the initial state can shift a measured centroid. Compare both individual integrated line areas at low intensity and reverse the field with the corresponding spin preparation. These tests use distinct symmetry and strength predictions rather than interpreting one centroid as a complete spectrum.
Further reading
Fluctuations, occupation and collective order
Connect an occupation probability to a heat capacity, a correlation length or a symmetry-breaking order parameter. Compare electrical measurements with a thermal fluctuation.
- Indistinguishable particles and quantum gases
- Vibrations and the Debye heat capacity
- Extracting a length from thermal spin fluctuations
- Why only a narrow shell of a Fermi gas carries heat
- Mean-field ordering, response and the critical point
- Measure equilibrium field fluctuations with a capacitor
- From mobile ions to screening lengths and differential double-layer capacitance
- Rotational and vibrational populations in a molecular gas
- Bose condensation, dimensionality and a finite trap
- Degenerate fermions, heat and magnetic response
- Finite-size criticality and the evidence for a phase transition
- How many lattice sites remember the colour of a neighbour?
Indistinguishable particles and quantum gases
Thermodynamics and statistical physics
Use single-state occupancy to derive Fermi–Dirac and Bose–Einstein distributions and estimate when classical gas statistics cease to apply.
From first principles
Derive the mean population of one quantum state
Consider a single-particle state of energy \(\epsilon\) exchanging particles and energy with a large reservoir at temperature \(T\) and chemical potential \(\mu\). In a noninteracting gas, occupation \(n\) of this state changes \(E-\mu N\) by \(n(\epsilon-\mu)\). Its statistical weight is \(q^n\), where \(q=e^{-(\epsilon-\mu)/(k_BT)}\). For one specified state including its spin label, fermions allow occupations 0 and 1. Bosons allow every nonnegative integer,
The Bose sum requires \(q<1\). Differentiating a weight with respect to \(q\) brings down its occupancy, so the normalized average is \(q\,\partial_q\ln Z\). Applying this to the two sums gives
For \(q\ll1\), both means approach \(q\); visits by additional particles to the same state are then rare. The difference between the distributions follows entirely from which occupation numbers the quantum statistics allow.
Derivation and applications
Derive the first exchange correction to ideal-gas pressure
Before quantum degeneracy becomes strong, exchange statistics already affect the relation between pressure and density. Consider noninteracting particles of mass \(m\) in a large three-dimensional box. All \(g\) internal states have the same energy and chemical potential. Introduce fugacity \(z=e^{\mu/(k_BT)}\), thermal wavelength \(\lambda_T=h/\sqrt{2\pi m k_BT}\), and a sign \(s=+1\) for bosons or \(-1\) for fermions. At small fugacity the occupation of a one-particle energy \(\epsilon\) is a geometric expansion,
Integrating the first term over momentum gives \(g/\lambda_T^3\) times \(z\). In the second term, doubling the inverse temperature narrows each Cartesian Gaussian by \(\sqrt2\). The density integral therefore gains a factor \(2^{-3/2}\). At fixed temperature the Gibbs–Duhem relation \(dp=n\,d\mu\) gives
Integration from the empty-gas limit gives the pressure series,
Experiments often fix density. Put \(y=n\lambda_T^3/g\) and invert the density series once to get
Substituting into the pressure eliminates the unmeasured chemical potential,
At fixed density exchange raises the pressure of fermions and lowers that of bosons. The magnitude grows on cooling because the thermal wavelength increases. Real interactions can also alter the pressure, and the truncated expansion requires small \(y\).
Worked example
Estimate a pressure excess for a dilute Fermi gas
Change the inputs and investigate this derivation.
A spin-balanced ideal Fermi gas has \(g=2\), \(n=2.00\times10^{18}\,\mathrm{m^{-3}}\) and \(\lambda_T=400\,\mathrm{nm}\). It has \(y=0.0640\) and \(p/(nk_BT)\simeq1.0113\). A measured classical pressure scale \(nk_BT=20.0\,\mathrm{pPa}\) would therefore acquire an exchange correction of about \(0.226\,\mathrm{pPa}\).
Second application
Recover density from a bosonic pressure deficit
Change the inputs and investigate this derivation.
A single-state Bose gas at known \(\lambda_T=500\,\mathrm{nm}\) gives
To leading order the deficit fixes \(y=0.0050\times2^{5/2}=0.0283\). The inferred density is
At unchanged temperature halving this density halves the fractional pressure deficit, whereas the absolute pressure correction falls by a factor of four.
Try it · Quantum virial
Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.
Decide which exchanges leave the state unchanged
An ideal classical gas can often be treated with Maxwell–Boltzmann statistics. Cooling the gas or increasing its density eventually makes wave packets overlap appreciably. For indistinguishable quantum particles, merely assigning names to exchanged particles must not create extra states. In an ideal gas one can instead specify the occupation of each single-particle state. Identical fermions occupy a given quantum state at most once, including its spin label. Identical bosons can accumulate in the same state.
Use a reservoir that exchanges both energy and particles with the system. Its temperature \(T\) and chemical potential \(\mu\) are fixed. A microstate with energy \(E\) and particle number \(N\) has grand-canonical weight proportional to \(\exp[-\beta(E-\mu N)]\). This follows by applying the thermodynamic entropy differential to a reservoir that loses both \(E\) and \(N\). The chemical potential sets the mean particle number through these statistical weights.
Sum the allowed occupancies of one state
For a single-particle state of energy \(\epsilon\), define \(z_\epsilon=\exp[-\beta(\epsilon-\mu)]\). An occupancy of \(n\) contributes weight \(z_\epsilon^n\). For fermions the single-state grand partition sum is \(1+z_\epsilon\), so the mean occupancy is \(z_\epsilon/(1+z_\epsilon)\). For bosons the sum runs over all nonnegative integers and equals \(1/(1-z_\epsilon)\), provided \(z_\epsilon<1\). Differentiating the logarithm of each sum with respect to \(\ln z_\epsilon\) gives
These expressions describe one state, not the total population within an energy interval. To get the latter, multiply by the density of states and integrate. If the exponential is large then both occupancies reduce to \(e^{-\beta(\epsilon-\mu)}\). The upper sign suppresses double occupancy while the lower sign enhances occupation near the lowest available energy.
Count the occupied sphere of a cold electron gas
In a large cubic volume \(V\) with periodic boundaries, allowed wave vectors fill reciprocal space with one state per volume \((2\pi)^3/V\) for each spin. At zero temperature the noninteracting electron gas fills all states inside a sphere of radius \(k_F\) and leaves higher ones empty. Including two spin states per wave vector gives \(N=2V(4\pi k_F^3/3)/(2\pi)^3\), so \(k_F=(3\pi^2N/V)^{1/3}\). For electrons of mass \(m_e\), the Fermi energy is \(\hbar^2k_F^2/(2m_e)\).
With density \(n=8.0\times10^{28}\) m⁻³, \(k_F=1.33\times10^{10}\) m⁻¹ and \(E_F\simeq6.77\) eV. The associated temperature \(T_F=E_F/k_B\) is approximately \(7.9\times10^4\) K. At room temperature \(k_BT\) is small compared with this energy, so only a narrow region around the Fermi surface changes occupation noticeably. A classical equipartition estimate of the electron contribution to heat capacity would ignore this restriction.
Test the dilute limit with a cold atomic gas
A useful scale for translational wave packets is the thermal wavelength \(\lambda_T=h/\sqrt{2\pi m k_BT}\). For a single internal state the dimensionless product \(n\lambda_T^3\) compares the volume per particle with the thermal wave volume. Small values support the dilute classical approximation. Near unity the occupancy of low-energy states can become appreciable and the statistics of indistinguishability matter.
For particles of mass \(6.6\times10^{-27}\) kg at 1.0 K the thermal wavelength is approximately 0.88 nm. At density \(10^{25}\) m⁻³, \(n\lambda_T^3\simeq0.0068\). Reducing temperature to 0.040 K at unchanged density multiplies that product by \(25^{3/2}=125\), giving about 0.85. This is a degeneracy estimate, not a prediction of the phase of a real interacting gas. Once quantum statistics matter, particle interactions, dimensionality and confinement can also affect which phase the experiment actually finds.
Internal degeneracy enters these comparisons through the density per available internal state. Suppose the same total particle density is spread equally across two spin states with identical spatial dispersion. Each can fill the same momentum levels independently. In a cold ideal Fermi gas the Fermi wavevector at fixed total density is then smaller than in a fully spin-polarized gas. A measured pressure change after altering spin populations can therefore contain a statistical contribution even if the mass, volume and total particle count remain fixed.
Determine the capacity of excited Bose states
Ideal bosons can accumulate macroscopically in one spatial state. Consider a uniform three-dimensional noninteracting gas of identical spinless particles with fixed particle number in a large box. Set the lowest energy to zero. The excited-state occupation at energy \(\epsilon\) is \(1/[\exp((\epsilon-\mu)/(k_BT))-1]\) and requires \(\mu\le0\). In the thermodynamic limit, counting momentum states in a sphere gives an excited-state density per volume proportional to \(\sqrt\epsilon\). Consequently, as the density rises, taking \(\mu\) toward zero from below can increase the excited population only up to a finite value.
Explicitly integrate \(d^3p/(2\pi\hbar)^3\) over positive energies \(\epsilon=p^2/(2m)\). At \(\mu=0\), setting \(x=\epsilon/(k_BT)\) reduces the integral to \(\int_0^\infty x^{1/2}/(e^x-1)dx=\Gamma(3/2)\zeta(3/2)\). The result is
Below the temperature where this capacity equals the total density, additional particles occupy the lowest state. Solving gives
The state count explains why a high phase-space density matters. Reaching this regime does not require individual particles to lose their identity at a sharply defined minimum separation.
Estimate the onset temperature in a box
Take \(n=1.00\times10^{20}\) m⁻³ and particle mass \(1.44\times10^{-25}\) kg. At the ideal transition the thermal wavelength is
Inverting its definition gives \(T_c=h^2/(2\pi m k_B\lambda_T^2)=0.398\) μK. At \(T=0.250\) μK, the excited fraction is \((0.250/0.398)^{3/2}=0.498\) and the condensate fraction is approximately 0.502. Doubling the density raises \(T_c\) by \(2^{2/3}=1.59\) at fixed particle mass.
The predicted fraction tends to zero continuously as \(T\) approaches \(T_c\) from below, and tends to one as temperature approaches zero for the ideal gas. A harmonic trapping potential has a different density of states and hence a different temperature exponent from a uniform box. Finite size smooths the mathematical onset; interactions and inaccurate thermometry can shift its inferred location. Comparing the number in the narrow lowest-momentum component with the thermal-cloud population requires that the analysis resolve these two contributions rather than simply count all particles near the centre of a spatial image.
The dimensionality of the gas is as essential as Bose exchange itself. In a uniform two-dimensional ideal box the single-particle density of states tends to a constant at low energy. At chemical potential approaching zero, Bose occupation varies as \(k_BT/\epsilon\) there. Its energy integral consequently diverges logarithmically rather than approaching a finite excited-state capacity. The three-dimensional derivation of a nonzero transition temperature cannot then be carried across unchanged. A finite box, a confining trap or interparticle interactions can all alter the observed low-energy behaviour and must be identified when comparing different experimental geometries.
Repeat the counting in a harmonic trap
A harmonic trap changes the number of available excited states even for particles with the same mass and statistics. For three oscillator frequencies \(\omega_x,\omega_y,\omega_z\), measure energy above the lowest level and suppose \(k_BT\) greatly exceeds each \(\hbar\omega_i\). The quantum labels \(n_i\) are nonnegative integers with energy \(\sum_i\hbar\omega_i n_i\). The count below energy \(E\) is approximately the volume of the positive-coordinate tetrahedron bounded by this plane, namely \(E^3/(6\hbar^3\omega_x\omega_y\omega_z)\). Differentiating gives an energy density of states proportional to \(E^2\).
At the onset of condensation integrate this density against \(1/(e^{E/k_BT}-1)\). The identity \(\int_0^\infty x^2/(e^x-1)\,dx=2\zeta(3)\) then gives
For \(N=1.00\times10^5\) particles in an isotropic 100 Hz trap, \(\hbar\bar\omega/k_B=4.80\) nK and \([N/\zeta(3)]^{1/3}=43.7\), so the predicted transition temperature is \(0.210\) μK. At \(0.150\) μK the condensate fraction is
An analysis using the uniform-box exponent at the same temperature ratio would instead give 0.396. The difference comes entirely from the confinement-dependent state count.
Reducing all three trap frequencies at fixed particle number lowers the onset temperature in direct proportion. This differs from enlarging a uniform box at fixed mean density, which leaves its bulk critical temperature unchanged. Specifying how particle number, volume and external confinement are controlled is therefore essential when interpreting a measured condensate fraction.
Vibrations and the Debye heat capacity
Thermodynamics and statistical physics
Count vibrational modes in a solid and explain why a crystal’s low-temperature heat capacity follows a cube law.
From first principles
Derive the low-temperature heat capacity from acoustic modes
In a large three-dimensional crystal, long-wavelength acoustic vibrations have approximately linear dispersion \(\omega=vk\). Count allowed wavevectors inside a sphere of radius \(k\). Its volume grows as \(k^3\), so the number of modes below \(\omega\) grows as \(\omega^3\). The frequency density is its derivative. In a single-speed model normalized to the \(3N\) displacements of \(N\) atoms,
Each mode stores mean thermal energy \(\hbar\omega/[e^{\hbar\omega/(k_BT)}-1]\). Multiply by the mode count and substitute \(x=\hbar\omega/(k_BT)\) to expose the temperature dependence,
When \(T\ll\hbar\omega_D/k_B\), the omitted tail above the upper limit is exponentially small. The integral approaches a constant, giving \(U_{\rm th}\propto T^4\) and \(C_V=(\partial U/\partial T)_V\propto T^3\). The cube law relies on both three-dimensional mode counting and linear low-frequency dispersion.
Derivation and applications
Recover the Debye velocity from distinct sound branches
A three-dimensional solid usually carries one longitudinal and two transverse acoustic polarizations. Their speeds can differ substantially. Consider a large elastically isotropic crystal of volume \(V\), with linear dispersion \(\omega=v_s k\) for each polarization \(s\) in the thermally populated range. Impose periodic boundaries; one wavevector state occupies reciprocal volume \((2\pi)^3/V\). For each polarization count all points in a sphere of radius \(\omega/v_s\), which includes opposite propagation directions. Differentiating gives the total density of modes,
A slower sound branch has more low-frequency states because the same frequency reaches a larger wavevector sphere. Define one effective velocity \(v_D\) to preserve this acoustic density of states. Requiring an isotropic monatomic Debye model to contain \(3N\) vibrations, with number density \(n=N/V\), fixes its frequency cutoff and temperature scale,
At low temperature the cutoff can be moved to infinity in the thermal energy integral. Changing variables to \(x=\hbar\omega/(k_BT)\) uses \(\int_0^\infty x^3/(e^x-1)\,dx=\pi^4/15\). A temperature derivative yields the directly measurable coefficient
The inverse cubes explain why replacing the three velocities by their arithmetic mean can noticeably underestimate the heat capacity. Optical or electronic contributions must be identified separately in specimens where they are thermally active.
Worked example
Predict the acoustic temperature scale
Change the inputs and investigate this derivation.
For \(v_L=6000\,\mathrm{m/s}\), \(v_T=3000\,\mathrm{m/s}\), the longitudinal branch contributes only \(1/17\) of the low-temperature coefficient. The effective velocity is
With \(n=5.00\times10^{28}\,\mathrm{m^{-3}}\), the cutoff wavevector is \(1.44\times10^{10}\,\mathrm{m^{-1}}\), giving \(\Theta_D\simeq369\,\mathrm K\). The long-wave estimates apply well below that scale.
Second application
Extract the transverse speed from calorimetry
Change the inputs and investigate this derivation.
Suppose a separate specimen gives \(v_D=2500\,\mathrm{m/s}\) from its low-temperature heat capacity and \(v_L=5000\,\mathrm{m/s}\) from a longitudinal pulse. Solving for the missing speed gives
A shear-wave transit across \(10.0\,\mathrm{mm}\) should consequently take \(4.51\,\mathrm{\mu s}\). This timing test uses a distinct mechanical measurement of the same states counted by calorimetry.
Try it · Debye speed
Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.
What a solid can store
Consider an electrically insulating three-dimensional crystal of \(N\) atoms, volume \(V\), sufficiently cold that its structure remains fixed and normal-mode frequencies vary weakly with temperature. In a harmonic approximation displacements about equilibrium separate into \(3N\) independent oscillators. Their excitations are called phonons. Phonon number is not conserved when the solid exchanges heat, so each mode has a Bose mean occupation with zero chemical potential. The modes exist because the crystal can deform, including at very long wavelengths.
A model assigning the same frequency to every oscillator predicts an exponentially small low-temperature heat capacity, since exciting any mode would require a fixed nonzero energy. Acoustic vibrations instead approach zero frequency as their wavenumber approaches zero. Even in a cold macroscopic crystal, long-wavelength modes can remain thermally accessible. The key quantity is how many have energies of order \(k_BT\) or less.
Test the single-frequency model before introducing a spectrum
The premise of the Einstein solid is deliberately restrictive. All \(3N\) vibrational coordinates of a crystal are independent harmonic oscillators with one frequency \(\omega_E\). For one coordinate the levels are \(E_n=\hbar\omega_E(n+1/2)\). Write \(x=\hbar\omega_E/(k_BT)=\Theta_E/T\). Summing the geometric series gives
The partition function of the crystal is \(Z_1^{3N}\), because each normal coordinate can be occupied independently and phonon number is free to change.
Apply \(-\partial\ln Z/\partial\beta\), with \(\beta=1/(k_BT)\), to obtain
The zero-point energy contributes no heat capacity at fixed volume. Differentiating the occupation term and using \(dx/dT=-x/T\) gives
At high temperature \(1-e^{-x}\simeq x\), so the heat capacity per mole of atoms approaches \(3R\). At low temperature the denominator tends to one, and the surviving factor \(x^2e^{-x}\) measures the cost of the lowest available excitation. For \(\Theta_E=240\) K the same mole would have \(C_V=18.06\) J/(mol K) at 120 K, \(7.585\) at 60 K and \(0.536\) at 30 K. Halving temperature does not give a fixed ratio. The curve crosses from a classical plateau to thermally rare excitations.
A real three-dimensional macroscopic crystal supports collective vibrations whose frequencies approach zero with wavelength increasing. Replacing the single frequency by a distribution puts modes below any fixed nonzero thermal scale. The next calculation finds the density of those modes, and therefore a low-temperature power law. High-temperature agreement alone cannot distinguish the two models since both count the same total number of coordinates.
Count to a cutoff
Use a continuum approximation with three acoustic polarizations and a common sound speed \(v\). The modes in a shell of wavevectors grow as \(k^2dk\), as for photons. Real crystals generally have distinct longitudinal and transverse speeds. An effective Debye speed averages their inverse cubes. Converting via \(\omega=vk\) gives density \(g(\omega)=3V\omega^2/(2\pi^2v^3)\). The continuum would supply infinitely many modes, whereas a crystal with \(N\) atoms has exactly \(3N\). Choose an upper cutoff \(\omega_D\) to match that count,
This cutoff is an approximate representation of the lattice at high wavenumber. The low-temperature prediction depends on the long-wave acoustic spectrum and is insensitive to precise details near the cutoff. In a multi-atom cell additional optical branches change the intermediate-temperature behaviour, which cannot generally be reconstructed with a single effective speed.
Two limits and a measurement
The thermal energy is the integral of \(g(\omega)\hbar\omega/[\exp(\hbar\omega/k_BT)-1]\) over the band. Define \(\Theta_D=\hbar\omega_D/k_B\). When \(T\ll\Theta_D\), extend the upper limit of the dimensionless integral to infinity. The resulting energy scales as \(T^4\) and differentiation yields
At high temperature each mode instead approaches \(k_BT\) of thermal energy and the heat capacity tends to \(3Nk_B\). The acoustic model has the correct count by construction. The constant zero-point energy never enters either heat capacity because it disappears upon differentiation.
For one mole of atoms with \(\Theta_D=300\) K, the low-temperature prediction at 10.0 K is \(0.0720\) J mol⁻¹ K⁻¹, far below the classical \(3R=24.9\) J mol⁻¹ K⁻¹. At 20.0 K the cubic asymptote predicts \(0.576\) J mol⁻¹ K⁻¹. Measuring several temperatures and plotting \(C/T^3\) tests the constant coefficient directly. In a conducting solid an electronic term proportional to \(T\) can dominate at low temperatures. Separating that term through a plot of \(C/T\) against \(T^2\) allows the intercept and slope to reveal the two physically distinct energy stores.
Finite size eventually supplies a lower frequency cutoff related to the crystal dimensions, so the continuum counting argument presupposes a specimen large enough to have many wavelengths populated throughout the temperature interval.
Connect vibrations to thermal expansion
A purely harmonic crystal with force constants independent of volume can store vibrational energy yet has no vibrational mechanism for thermal expansion. Real vibrational frequencies usually vary as the lattice spacing changes. The quasiharmonic approximation treats each mode as harmonic at each volume while allowing its angular frequency \(\omega_j(V)\) to change smoothly. Define the mode Grüneisen parameter \(\gamma_j=-\partial\ln\omega_j/\partial\ln V\). A positive value means expansion softens that mode.
For one oscillator the Helmholtz free energy is
Differentiation at fixed \(T\) gives
where \(U_j\) includes the zero-point energy and the mean thermal excitation. Since vibrational pressure is \(-\partial F/\partial V\), the chain rule gives
A temperature derivative at fixed volume suppresses the constant zero-point contribution. The mechanical relation \((\partial p/\partial T)_V=\alpha_V B_T\) finally yields
Here \(B_T\) is the isothermal bulk modulus and \(\alpha_V\) the volume expansion coefficient. The mode sum weights each Grüneisen parameter by its thermally active heat capacity. A low-frequency mode that softens under compression can contribute negatively and can dominate in a cold crystal while high-frequency modes remain frozen. A single positive average parameter is therefore a material model rather than a thermodynamic necessity.
Infer a mode average from dilatometry
For a cubic crystal take measured molar heat capacity \(C_{V,m}=12.0\) J/(mol K), molar volume \(V_m=1.20\times10^{-5}\) m³/mol and bulk modulus \(B_T=100\) GPa. A measured linear expansion coefficient \(6.00\times10^{-6}\) K⁻¹ corresponds to \(\alpha_V\simeq3\alpha_L=1.80\times10^{-5}\) K⁻¹. The effective heat-capacity-weighted parameter is then
The factor of three comes from differentiating the cube of a length, not from counting acoustic polarizations again.
If the same positive average and bulk modulus remain approximately constant down to a regime where phonons give \(C_V\propto T^3\), the volume expansion coefficient should also fall as \(T^3\). Doubling temperature there increases the coefficient by about eight, although the accumulated length change requires integrating it over temperature. A comparison of \(\alpha_V/C_V\) at several temperatures can test whether the active modes really share a common volume sensitivity. Molar heat capacity and molar volume must be taken on the same chemical counting basis before inferring any dimensionless Grüneisen parameter.
Hydrostatic pressure spectroscopy gives an independent way to measure a mode parameter. By the chain rule, the definition yields \(\gamma_j=B_T(\partial\ln\omega_j/\partial p)_T\) within the quasiharmonic description. For the numerical bulk modulus, a mode with parameter 1.80 would increase its frequency by approximately 1.8 percent under a 1.00 GPa hydrostatic pressure increment. Agreement between this slope and the value inferred from expansion requires that the probed mode be representative of the thermally populated spectrum. A strong optical mode visible to a spectrometer need not dominate low-temperature heat capacity or expansion.
Quoted pressure derivatives must therefore specify the mode, the temperature and whether hydrostatic or directional stress was applied in the measurement.
Which lattice heat capacities survive at low temperature?
Compare a linear acoustic spectrum with a single oscillator frequency. Scale each temperature by its model’s characteristic temperature. The Debye prediction uses numerical quadrature of \(3t^3\int_0^{1/t}x^4e^x/(e^x-1)^2\,dx\); both expressions approach unity at high temperature.

Try it · Einstein debye
Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.
Read values from the plot
| Temperature / characteristic temperature | Debye continuum | Einstein single frequency |
|---|---|---|
| 0.025 | 0.0012176 | 6.7974e−15 |
| 0.08216 | 0.042949 | 0.00076686 |
| 0.27001 | 0.54841 | 0.35519 |
| 0.91285 | 0.94248 | 0.90572 |
| 3 | 0.99447 | 0.99079 |
Extracting a length from thermal spin fluctuations
Thermodynamics and statistical physics
A one-dimensional row of magnetic moments favours local alignment. At low temperature a snapshot can contain a long row of identical spins. An exact calculation distinguishes a large correlated domain from a thermodynamic phase with permanent order.
Sum all configurations by multiplying a small matrix
Consider \(N\) classical spins \(s_j=\pm1\) on a ring with \(s_{N+1}=s_1\). At zero applied field the energy is \(-J\sum_j s_js_{j+1}\) with \(J>0\). The Boltzmann weight factors into nearest-neighbour terms \(e^{Ks_js_{j+1}}\), with \(K=J/(k_BT)\). Construct the matrix \(T_{ss'}=e^{Kss'}\), whose diagonal elements are \(e^K\) and off-diagonal elements \(e^{-K}\). Multiplying \(T\)'s automatically sums each intermediate spin over its two choices. Closing the first and last indices gives
The symmetric and antisymmetric vectors \((1,1)/\sqrt2\) and \((1,-1)/\sqrt2\) have eigenvalues \(\lambda_+=2\cosh K\) and \(\lambda_-=2\sinh K\). Thus \(Z_N=\lambda_+^N+\lambda_-^N\). At every finite positive temperature the ratio of eigenvalues is strictly below one. In the large-system limit the free energy per spin is \(-k_BT\ln(2\cosh K)\). Differentiating with respect to \(\beta\) yields the energy per spin \(-J\tanh K\).
Background · Connected correlation
Subtract the independent contribution before identifying a decay length. A periodic sample introduces a second propagation distance around the ring.
Insert two local measurements
Multiplying an individual configuration by a measured spin corresponds to inserting \(S=\operatorname{diag}(1,-1)\) in the matrix trace. To measure two sites separated by \(r\) bonds use \(\operatorname{tr}(ST^rST^{N-r})/Z_N\). In the eigenbasis of \(T\), \(S\) exchanges the symmetric and antisymmetric vectors. The numerator therefore contains one factor \(\lambda_-^r\lambda_+^{N-r}\) and one with the eigenvalues exchanged. With \(q=\lambda_-/\lambda_+=\tanh K\),
Here \(a\) is the lattice spacing and the infinite-chain limit holds for fixed \(r\). The second finite-ring term comes from the other way around the circle. At equal sites the full ratio equals one. In zero field spin reversal makes the mean spin zero in the thermal distribution. Thus this correlation already equals the connected correlation.
Compare a chain at two temperatures
At \(k_BT=J\), \(q=0.7616\) and \(\xi=3.67a\). Spins ten bonds apart have correlation only \(0.0657\). At \(k_BT=0.5J\), \(\xi=27.30a\) and the corresponding correlation is \(0.693\). Lower temperature suppresses individual domain walls. Since \(s_js_{j+1}\) is +1 for alignment and −1 for a wall, its average equals \(1-2P_{\rm wall}=q\). At low temperature \(P_{\rm wall}\simeq e^{-2K}\) and \(\xi/a\simeq e^{2K}/2\). Even rare walls eventually destroy alignment in a sufficiently long chain.
Compare the finite ring with the infinite-chain result. Change the ring length while leaving the temperature fixed. When the correlation length becomes comparable to the circumference, the long route contributes appreciably. Returning to the starting site must restore correlation one. A straight-line fit to the back half of a semilog finite-ring plot would consequently give a misleading decay length.
Tutorial on estimating an interaction
In a very long zero-field chain the nearest-neighbour correlation is 0.6. Determine \(J/(k_BT)\), the probability of a wall on a given bond and the separation at which correlation first falls below 0.1.
Work through the solution
Invert \(q=\tanh K\) to obtain
The wall probability is
Solve \(r>\ln(0.1)/\ln(0.6)=4.51\). At five bonds the correlation is 0.07776. An even number of walls can restore the original spin direction, so this correlation counts more than the probability of finding a completely wall-free interval.
At \(k_BT=J\) a nearest-neighbour bond is aligned with probability \(p\). Find \(p\) and its relation to the mean energy per bond.
Work through the solution
The correlation is \(2p-1=\tanh1=0.7616\), so \(p=0.8808\). Multiplying \(2p-1\) by \(-J\) gives \(-0.7616J\). This directly connects counts of local defects in snapshots with the thermodynamic energy obtained from the partition function.
Why can an odd number of walls never occur on a closed ring? Would dropping the finite-ring correction give the correct wall count at arbitrary temperature?
Work through the solution
Each wall reverses the spin when following the ring. Returning to the starting site requires an even number of reversals. The exact nearest-neighbour correlation is \((q+q^{N-1})/(1+q^N)\). Thus the mean wall count is \(N(1-C_1)/2\). Approximating \(C_1\) by \(q\) works when \(N\) substantially exceeds the correlation length; otherwise ring closure changes the result.
Further reading · Cambridge statistical physics, Ising chain and correlation functions · Cambridge statistical mechanics, phase transitions and transfer matrices.
Why only a narrow shell of a Fermi gas carries heat
Thermodynamics and statistical physics
Heating a filled Fermi sea does not give every particle a classical thermal energy. Deep below the chemical potential, nearby states are already occupied. Quantifying the accessible states predicts both the low-temperature heat capacity and the shift of the chemical potential at fixed particle number.
Convert a sharp Fermi surface into a narrow weight
For independent fermions with occupancy \(f(E)=1/[1+\exp((E-\mu)/(k_BT))]\), consider integrals \(I=\int_0^\infty H(E)f(E)\,dE\). Choose \(F(E)=\int_0^E H(s)ds\). Integration by parts gives \(I=\int_0^\infty F(E)[-\partial_E f(E)]dE\), since the boundary terms vanish. The derivative is a peak of width \(k_BT\) around \(\mu\). With \(x=(E-\mu)/(k_BT)\) the weight becomes
For \(\mu\) many thermal units above the bottom and \(H\) smooth over the thermal shell, extend the lower limit to \(-\infty\) when expanding locally around \(\mu\). The weight has unit integral and is even, so the linear term in \(F(\mu+k_BTx)\) integrates to zero. Its second moment is \(\pi^2/3\), obtained by expanding \(w(x)=\sum_{\ell\ge1}(-1)^{\ell+1}\ell e^{-\ell x}\) on \(x>0\) and integrating \(x^2\) termwise. Since \(F''=H'\),
The first correction samples the slope of the smooth weighting function. If a band edge or singularity lies within the shell, replacing the lower limit and Taylor expanding are poor approximations.
Conserve the number of particles
For a three-dimensional parabolic dispersion the density of states is \(D(E)=A\sqrt E\). At \(T=0\), \(N=(2A/3)E_F^{3/2}\). At small \(T\), use the expansion with \(H=D\) and write the chemical potential as \(E_F+\delta\mu\), where \(\delta\mu=O(T^2)\). Subtract the zero-temperature count. To quadratic order \(0=D(E_F)\delta\mu+(\pi^2/6)(k_BT)^2D'(E_F)\). Because \(D'/D=1/(2E_F)\),
The increasing density of states offers more available levels just above the Fermi energy than just below it. The chemical potential shifts down to preserve the count. At \(T/T_F=0.10\) the predicted shift is \(-0.00822E_F\). For an ideal gas with \(E_F=5.0\,\mathrm{eV}\), this particular reduced temperature corresponds to about 5800 K, so reduced temperature and ordinary laboratory temperature should be distinguished.
Differentiate the energy at fixed number
Use \(H=ED\) in the same integral, including the just-derived shift of \(\mu\). The boundary shift contributes \(E_FD(E_F)\delta\mu\). In the Sommerfeld term the derivative is \(D(E_F)+E_FD'(E_F)\). The terms involving the slope of \(D\) cancel after fixing number. Thus \(U-U_0=(\pi^2/6)D(E_F)(k_BT)^2\), and \(C_V=(\pi^2/3)D(E_F)k_B^2T\). In three dimensions \(D(E_F)=3N/(2E_F)\), giving \(C_V/(Nk_B)=(\pi^2/2)T/T_F\). This is an electronic contribution for independent particles. Other degrees of freedom such as phonons can dominate a measured material heat capacity.
The experiment reconstructs \(\mu\) by numerical integration and bisection at fixed number. It overlays the asymptotic prediction, allowing the fractional error to be checked before using it at larger \(T/T_F\). The quadrature uses the momentum-like substitution \(E/E_F=y^2\) to remove the square-root endpoint singularity.
Tutorial on interpreting heat-capacity data
For a gas with \(E_F=4.0\,\mathrm{eV}\) at \(T=300\,\mathrm K\), estimate \(C_V/(Nk_B)\) and the chemical-potential change in eV. Use \(k_BT=0.02585\,\mathrm{eV}\).
Work through the solution
The reduced temperature is \(0.00646\). The heat capacity ratio is approximately \(0.0319\), and \(\delta\mu=-(\pi^2/12)(0.02585)^2/4.0=-1.37\times10^{-4}\,\mathrm{eV}\).
A two-dimensional parabolic band has constant density of states above its edge. What does the quadratic expansion predict for the fixed-number chemical potential and energy?
Work through the solution
\(D'=0\) makes the quadratic shift of \(\mu\) vanish as long as the edge is distant. The energy integral still uses \((ED)'=D\), so it has a positive \(T^2\) correction. Effects of the distant band edge can give exponentially small departures in \(\mu\).
Further reading · Cambridge statistical physics, degenerate Fermi gas and Sommerfeld expansion.
Mean-field ordering, response and the critical point
Thermodynamics and statistical physics
Interactions can make a magnet favour a nonzero moment even when the applied field vanishes. Averaging the local exchange field gives a solvable model whose critical predictions can be compared with the exact one-dimensional chain.
Build the free energy from the count of spin states
Take \(N\) spins \(s_i=\pm1\), nearest-neighbour energy \(-J\sum_{\langle ij\rangle}s_is_j\) and Zeeman energy \(-h\sum_i s_i\), where \(h\) has energy units. Denote mean spin by \(m\). The fractions of positive and negative spins are \(p_\pm=(1\pm m)/2\). The binomial count and Stirling's approximation give entropy per spin \(-k_B(p_+\ln p_++p_-\ln p_-)\). Independent-neighbour mean field replaces each pair average by \(m^2\). With \(z\) neighbours and each bond counted once, interaction energy per spin becomes \(-zJm^2/2\).
Differentiate at fixed \(T,h\). The entropy contribution has derivative \(k_BT\operatorname{atanh}m\), giving \(m=\tanh[(zJm+h)/(k_BT)]\). This equation can have three real roots, so an iterative solver returning a root alone is insufficient. The equilibrium phase minimises \(f\); the second derivative \(k_BT/(1-m^2)-zJ\) distinguishes local minima and maxima.
Expand about the loss of stability
Near zero magnetisation,
Set \(T_c=zJ/k_B\) and integrate the expanded derivative to obtain
At zero field and \(T>T_c\), \(m=0\) is stable. Below \(T_c\), symmetry gives two minima whose leading magnitudes satisfy \(m^2\simeq3(T_c-T)/T\). Thus the order parameter vanishes like \((T_c-T)^{1/2}\) close to \(T_c\). At \(T=T_c\) a small nonzero field instead gives
These powers describe this model's limiting behaviour. For a finite sample symmetry makes the unbiased ensemble average zero if it samples both minima. Spontaneous magnetisation refers to the thermodynamic limit with an infinitesimal field selecting a sign.
Compute a response, then compare with an exact counterexample
Above \(T_c\) the small-field stationary equation gives
Below \(T_c\), differentiate the exact stationarity equation on the positive branch, obtaining \(\chi=[k_BT/(1-m^2)-zJ]^{-1}\). Expanding near \(T_c\) there gives \(\chi\simeq[2k_B(T_c-T)]^{-1}\), half the above-transition amplitude at equal distance. At \(T=0.8T_c\), the full zero-field solution is about \(m=0.7104\); the small-\(m\) estimate \(\sqrt{3(1-0.8)/0.8}=0.866\) is already visibly inaccurate.
Mean field predicts an ordering temperature even for a one-dimensional chain with \(z=2\). The exact finite-temperature correlation length in the earlier transfer-matrix solution is finite at all \(T>0\). Spatial fluctuations and domain walls invalidate the independent-neighbour closure in one dimension. The experiment plots the full mean-field free energy and its quartic approximation for the same normalised \(T,h\). Find the minima before inspecting the calculated order parameter. Compare how a weak bias changes their relative depths.
Tutorial on critical response
At \(T=1.10T_c\), what is the linear-response mean spin expected at \(h/(k_BT_c)=0.002\)? At the critical point use the cubic equation to estimate \(m\) for the same field.
Work through the solution
Above the transition \(m\simeq0.002/0.10=0.020\). At criticality \(m\simeq(0.006)^{1/3}=0.182\). The larger response signals the loss of the quadratic restoring term; linear extrapolation through \(T_c\) would give a divergent susceptibility.
At \(h=0\) and \(T=0.95T_c\), is \(m=0\) a possible output from a fixed-point solver? How should an equilibrium calculation prevent a wrong interpretation?
Work through the solution
Starting the symmetric iteration at exactly zero returns zero repeatedly, even below \(T_c\). Its free-energy curvature is \(k_B(T-T_c)<0\); it is a local maximum. Compare the free energies or bracket the two symmetry-related nonzero stationary points before reporting an equilibrium moment.
Further reading · Cambridge statistical physics, mean-field Ising and Landau theory.
Measure equilibrium field fluctuations with a capacitor
Fields and the response of matter
Derive an electrical noise measurement in two ways, determine what fraction reaches a finite-bandwidth detector and use agreement to calibrate an experiment.
A zero-average voltage can store measurable energy
Connect a capacitor \(C\) across a resistor \(R\) at a uniform absolute temperature \(T\), with no external drive. Ideal circuit equations predict that any deliberately deposited charge decays on time scale \(RC\). At thermal equilibrium, microscopic fluctuations continually exchange charge and energy with the capacitor. Symmetry gives zero mean voltage, but the stored energy involves \(V^2\). In the classical limit a quadratic degree of freedom has mean energy \(k_BT/2\), giving \(\langle V^2\rangle=k_BT/C\). The resistor sets the time scale of equilibration; equilibrium mean-square voltage does not depend on resistance in this ideal model.
Check the dimensions: \(k_BT\) is an energy in joules and capacitance has units coulombs per volt. Their ratio is volts squared. At \(T=300\) K and \(C=100\) pF the RMS voltage is \(\sqrt{k_BT/C}\simeq6.44\ \mu{\rm V}\). A voltmeter that averages the signed voltage for a long time reports a value near zero. Measuring the noise requires an RMS, variance or appropriately calibrated spectral measurement.
Derive the same variance from a spectral measurement
Use a one-sided voltage power spectral density per hertz at positive frequencies. The classical Johnson–Nyquist open-circuit result for a resistor is \(S_R(f)=4k_BTR\) V²/Hz. Its square root is an amplitude spectral density in V/\(\sqrt{\mathrm{Hz}}\), not a voltage variance. Use an equivalent series voltage noise source and the RC transfer function \(H(f)=1/[1+2\pi i fRC]\). A stationary linear system multiplies the voltage power spectrum by \(|H|^2\), so
\int_0^\infty S_C(f)\,df=\frac{k_BT}{C}.
The integral follows by \(u=2\pi RCf\) and \(\int_0^\infty du/(1+u^2)=\pi/2\). It furnishes a detailed check on the factor four, the use of one-sided density, the conversion from hertz to angular frequency and the amplitude-versus-power distinction. If your result disagrees by a constant factor of two or \(2\pi\), audit these conventions before assigning a new noise temperature.
For \(R=10\) kΩ, \(T=300\) K, the low-frequency amplitude spectral density is approximately 12.9 nV/\(\sqrt{\mathrm{Hz}}\). The RC corner at \(C=100\) pF is \(f_c=1/(2\pi RC)\simeq159\) kHz. The open-circuit low-frequency density rises with \(R\) while the bandwidth shrinks in inverse proportion. Their integrated product gives the earlier resistance-independent variance.
Include a real observation bandwidth
Suppose a first measurement adds an ideal low-pass cutoff \(B\). The recorded fraction of equilibrium variance is \(F=(2/\pi)\arctan(B/f_c)\). Half of the noise variance lies below the RC corner. That may be surprising if the corner was introduced as the frequency at which the spectral density reaches half its zero-frequency value. These two properties coincide for this single-pole spectrum for different mathematical reasons.
At \(B=0.1f_c\), \(F\simeq0.06345\), so the recorded RMS is about 25.2% of the infinite-band RMS. At \(B=10f_c\), \(F\simeq0.93655\), giving about 96.8% of the RMS. In an experiment, taking a square root one step too early changes this comparison. A real detector transfer function replaces the sharp cutoff by an integral of \(S_C(f)|H_\mathrm{det}(f)|^2\).
Sweep the resistance by a factor ten. Observe how the corner moves along the frequency axis and how the fraction measured in a fixed bandwidth changes. Then vary temperature. In the classical regime spectral density and integrated variance are proportional to \(T\), while RMS voltage grows only as \(\sqrt T\). A plot labelled “noise” without units cannot distinguish these two dependencies.
Background · How does a longer voltage exposure alter the measured noise?
An equilibrium resistor–capacitor circuit has voltage covariance \(C_v(s)=(k_BT/C)\exp(-|s|/\tau)\), where \(\tau=RC\). Suppose a digitiser returns the mean voltage during an exposure \(T_m\). Squaring a sample of this mean measures a different variance from averaging the instantaneous voltage squared. In the classical stationary model the two-time integral becomes
Short exposures recover \(k_BT/C\). At ten correlation times only about 18% of that variance remains. For very long exposures the variance decreases as \(2\tau/T_m\). Taking more closely spaced samples of one exposure cannot undo that averaging.
A physical check and a calibration check
An RC time-domain experiment provides a second observable beyond integrated power. Under the same single-pole equilibrium model the voltage autocovariance is
Its variance at zero lag agrees with equipartition, and its decay time is obtained from the homogeneous charge-relaxation equation. Repeating the measurement with a known extra parallel capacitance lowers the RMS and lengthens the correlation time. Seeing only one of those changes suggests that the observed noise may include substantial amplifier input voltage or an independent background.
The classical approximation assumes \(hf\ll k_BT\) over the relevant band and a resistor that can be treated as frequency independent. A MHz room-temperature experiment is far inside this regime. At sufficiently high frequencies or cryogenic temperatures, a quantum noise model, an explicit definition of the measured ordering of the spectrum and the detector's energy exchange are needed. Extending an ideal classical white source to infinite frequency is only permissible as an approximation inside the convergent low-frequency RC calculation; it is not a microscopic model at arbitrarily high frequency.
Tutorial
At fixed \(C,T\), doubling \(R\) in a detector with \(B\ll f_c\) changes the measured RMS by what factor? Will the same factor apply when \(B\gg f_c\)?
Work through the solution
At very small bandwidth, \(S_C\simeq4k_BTR\) is nearly constant, so variance doubles and RMS increases by \(\sqrt2\). At large bandwidth the measurement approaches \(k_BT/C\) and becomes independent of \(R\).
A two-sided spectrum in hertz is used instead. What density and integration limits preserve the same variance?
Work through the solution
For this real voltage, the density for each sign of frequency is half the one-sided positive-frequency value. Integrate it over \((-\infty,\infty)\). Integrating the one-sided density over both signs would count the power twice.
A measured RMS is 10 μV, including independent amplifier noise of 6 μV RMS. Can 6 μV simply be subtracted to infer the sample contribution?
Work through the solution
Independent zero-mean voltages add in variance. The inferred sample RMS is
A deterministic offset or correlated noise would require a different treatment.
Compare with an actual laboratory
The MIT Junior Lab noise experiment treats the detector as part of the measurement. Identify its calibration observable before comparing the theoretical density with an instrument reading.
From mobile ions to screening lengths and differential double-layer capacitance
Electrostatic field theory and measurement
A charged planar wall in an electrolyte can be studied without assuming a capacitance in advance. Diffusion and electrostatic drift first establish an ion cloud. The charge–voltage slope of that cloud is an experimental output of the model.
An electric field competes with entropy of mixing
Take a bulk reservoir containing mobile ions with charges \(+e,-e\), each at number density \(n_b\). The solvent is a uniform continuum of permittivity \(\epsilon\), the bath holds absolute temperature \(T\), and no reactions or Faradaic currents occur at the wall. At thermal equilibrium the electrochemical potential of each species is spatially constant. For an ideal dilute gas of particles it contains \(k_BT\ln(n_\pm/n_b)\) from mixing plus electrostatic energy \(\pm eV\). Set the bulk potential to zero. Equating the local and bulk electrochemical potentials yields
At positive \(V\) the negative counterions concentrate and the positive coions are depleted. Total mobile charge is
Substituting into Poisson's equation and defining dimensionless \(\psi=eV/(k_BT)\) gives
The parameter \(n_b\) is a density of one species, not both together. For a 1:1 salt specified in mol/litre convert to formula units per cubic metre using \(1000N_A\) before substitution. For a mixture the linear screening coefficient generalises to \(e^2\sum_i z_i^2n_i/(\epsilon k_BT)\), whereas the full nonlinear right-hand side remains a sum of exponentials. An externally maintained reservoir fixes chemical potentials; a sealed very small cell can instead require separate number conservation for every species.
What the small-potential limit predicts and what it neglects
For \(|\psi|\ll1\), replace \(\sinh\psi\) by \(\psi\). Above a planar wall at \(z=0\) with prescribed potential \(V_s\) and \(V\to0\) far away, the bounded solution is
With the normal into liquid \(+\hat{\mathbf z}\), the wall displacement is
For a conducting wall with no interior field this equals its free surface charge. Therefore \(C_{\rm diff}/A=d\sigma/dV_s=\epsilon\kappa\), dimensionally a dielectric layer of thickness \(\kappa^{-1}\). The ionic concentration actually varies continuously; it is not a plate of opposite charge located at that distance.
Integrating charge density \(-\epsilon\kappa^2V(z)\) over \(z>0\) gives
The screening cloud and wall together are neutral per area. The fraction of compensating charge within distance \(h\) is \(1-e^{-\kappa h}\). At one screening length the potential has fallen to \(1/e\) and \(63.2\%\) of the countercharge has accumulated. For a spherical bead curvature changes this simple relationship between potential ratio and enclosed charge. The ionic constitutive relation is the same, but the spatial Laplacian and collecting area differ.
With \(\epsilon_r=78.5,\ T=298\) K and \(1.00\) mM of a fully dissociated symmetric monovalent salt, \(n_b\simeq6.02\times10^{23}\) m⁻³ and \(\kappa^{-1}\simeq9.62\) nm. The linear diffuse capacitance is about \(0.072\) F/m². Increasing concentration fourfold halves the screening length and doubles this capacitance at fixed solvent response. Close to molecular length scales the continuum assumptions and concentration-independent permittivity become progressively questionable, so the square-root law should be tested in the intended concentration range.
Background · How small is a small electrostatic potential?
In a symmetric electrolyte the mean charge term is proportional to \(\sinh u\), with \(u=ze\psi/(k_BT)\) measured relative to the neutral reservoir. A potential being small in volts gives no absolute criterion: the valence and temperature set the relevant scale. Taylor expansion yields the fractional error in replacing the ionic source by its linearised value,
For roughly 1% local source accuracy this estimate asks for \(|u|\lesssim0.245\). At 298 K it gives about 6.3 mV for monovalent ions and 3.1 mV for divalent ions. This is a criterion on the local differential equation. An integrated charge or differential capacitance can have a different relative error and merits its own check.
Solve the nonlinear planar boundary problem
With planar symmetry \(\psi''=\kappa^2\sinh\psi\). Multiply both sides by \(\psi'\) and integrate from the remote bulk where \(\psi,\psi'\to0\). This gives
Choose the branch \(\psi'=-2\kappa\sinh(\psi/2)\), which decays to zero for either sign of surface potential. The identity \(d\ln|\tanh(\psi/4)|/d\psi=[2\sinh(\psi/2)]^{-1}\) turns the separated equation into
The physical potential itself is not a simple exponential at finite bias. Its distant tail has the same decay length but extrapolates back to a different amplitude \(4\tanh(\psi_s/4)\) in dimensionless units. A far-field slope can therefore recover \(\kappa\), while a linear extrapolation of its intercept underestimates large surface potentials. The nonlinear solution reduces continuously to the linear one because \(\tanh x\sim x\).
At \(z=0\), using \(D_z=-\epsilon k_BT\psi'/e\) gives
The first relation is odd in surface voltage and the differential capacitance is even for this symmetric salt model. Increasing voltage concentrates counterions and allows more charge per further voltage increment. For \(V_s=50\) mV at 298 K, \(V_s/(2k_BT/e)\simeq0.973\). The differential capacitance is about \(1.51\) times its zero-bias value, while the secant ratio \(\sigma/V_s\) is only about \(1.17\) times that value. A small AC perturbation superposed slowly about a DC bias measures the differential slope if ionic transport remains equilibrated.
An independent mechanical check of the nonlinear field
The ideal mobile ions have an osmotic pressure excess relative to the reservoir \(\Delta p=k_BT(n_++n_--2n_b)=2n_bk_BT(\cosh\psi-1)\). From the first integral the electrical normal stress magnitude \(\epsilon E^2/2\) equals this excess. Thus \(\Delta p-\epsilon E^2/2\) is spatially constant and vanishes in the bulk of the isolated-wall problem. One can derive the same result by differentiating the pressure: \(d\Delta p/dz=\rho E\) at equilibrium. The cancellation provides a sensitive joint test of the ion distribution and the potential gradient.
Confine electrolyte between two equal positively biased parallel walls instead. By symmetry \(E=0\) at the midplane but \(\psi_m\) generally remains positive. The constant excess normal pressure is then \(2n_bk_BT(\cosh\psi_m-1)>0\). Overlap of the diffuse layers produces a repulsive osmotic force per area in this mean-field model. With large separation the midplane potential tends to zero and so does that force. A solution built by naively superposing two high-voltage nonlinear wall profiles will generally violate the constant-pressure test.
Separate a near-wall compact layer from the diffuse response
A finite exclusion distance for ion centres near a real electrode can be modelled at first by a compact dielectric layer of capacitance per area \(c_s\). Its voltage drop is \(\sigma/c_s\); the diffuse layer starts at potential \(V_d\). For applied bias measured relative to the bulk and a chosen neutral reference,
Differentiate with respect to surface charge:
The diffuse constitutive relation must use \(V_d\), not the entire applied voltage. For \(c_s=0.20\) F/m² and low-bias \(c_d=0.072\) F/m², the measured capacitance is about 0.053 F/m². Even as \(c_d\) grows, this simple series model cannot exceed \(c_s\). It offers a physically distinct explanation for a measured saturation, alongside finite ion size, adsorption, dielectric variation and other model extensions. A static capacitance measurement alone cannot uniquely distinguish all of them.
Use layer overlap to infer a mechanical force independently of capacitance
Consider identical parallel electrodes at \(z=\pm H\), held at the same small positive potential \(V_s\) relative to a salt reservoir in chemical equilibrium with the gap. Neither electrode is an ordinary reference for the other: a voltage meter connected only between them reads zero while each diffuse layer experiences a nonzero potential relative to the reservoir. Under the linear screening approximation the potential obeys \(V''=\kappa^2V\). Reflection symmetry enforces \(V'(0)=0\). Matching both wall potentials gives \(V(z)=V_s\cosh(\kappa z)/\cosh(\kappa H)\), so the midplane voltage is
The magnitude of free charge per area on each inner electrode face is \(\epsilon\kappa V_s\tanh(\kappa H)\). At large \(H\) each plate recovers its isolated-wall charge. At small \(H\) the whole gap is nearly at \(V_s\), so very little normal field is required to maintain it and each facing surface carries less charge. This behaviour differs from two oppositely biased plates, whose nearly uniform internal field grows as their separation decreases. The reservoir reference and voltage symmetry decide which experiment is being performed.
To leading nonzero order in \(V_s\), the osmotic excess force per area between these identical walls can be found at the field-free midplane. There it is \(2n_bk_BT(\cosh\psi_m-1)\simeq n_b k_BT\psi_m^2=\epsilon\kappa^2V_s^2/[2\cosh^2(\kappa H)]\). Why use a term quadratic in \(V_s\) when the potential was found linearly? The pressure's zeroth-order excess vanishes and the first-order ionic density changes cancel between opposite species. Its first measurable correction is quadratic. The cubic error in the linear potential changes the computed pressure only at fourth order in \(V_s\), making the mixed expansion consistent.
For \(\kappa^{-1}=10\) nm, \(\epsilon=78.5\epsilon_0\) and \(V_s=5.0\) mV, at half-gap \(H=10\) nm the predicted repulsive pressure is about 36.5 Pa. At \(H=20\) nm it drops to roughly 6.14 Pa. The potential rose by only a few millivolts yet its ionic osmotic consequence extends across the entire overlap region. As \(H\) becomes large, \(\cosh^{-2}(\kappa H)\simeq4e^{-2\kappa H}\), giving exponential decay with the full separation \(2H\). This is a force measurement of the same screening scale measured independently by a voltage probe. Surface roughness, salt exclusion and adsorption can influence a real nanometre-scale force curve and should be distinguished from deviations in the bulk screening length.
If the electrode charges rather than their potentials are fixed, the wall derivative is prescribed. The even solution then has \(V_m=\sigma/[\epsilon\kappa\sinh(\kappa H)]\) in the linear regime, and pressure \(\sigma^2/[2\epsilon\sinh^2(\kappa H)]\). As \(H\) shrinks the linear approximation will eventually fail for fixed nonzero \(\sigma\), because \(V_m\) grows. Comparing the constant-potential and constant-charge formulas without adjusting their boundary conditions could suggest contradictory predictions where each applies to a different experiment.
Estimate how quickly the ion cloud can follow a capacitance measurement
Static Poisson–Boltzmann theory assumes ions are in equilibrium at each measured voltage. A time-dependent measurement can test that assumption. For dilute symmetric monovalent ions with equal diffusivity \(D_i\), small density perturbations obey the linearised number fluxes \(\mathbf j_\pm=-D_i[\nabla\delta n_\pm\pm e n_b\nabla V/(k_BT)]\), combining diffusion with electric drift. Assume no bulk reactions. Subtract the two continuity equations and multiply by \(e\), yielding a charge-current density \(\mathbf J=-D_i[\nabla\rho+2 e^2 n_b\nabla V/(k_BT)]\). Use \(\nabla^2V=-\rho/\epsilon\) in the bulk to obtain
A spatial harmonic of wavenumber \(k\) decays at rate \(D_i(k^2+\kappa^2)\) in the unbounded linear bulk model. The long-wavelength Debye charge-relaxation time is \(\tau_D=1/(D_i\kappa^2)\), also recovered by dividing permittivity by the dilute ionic conductivity \(\sigma_{\rm ion}=2 e^2n_bD_i/(k_BT)\). The total salt-density perturbation instead obeys ordinary diffusion because the leading positive and negative drift terms cancel. Fast local charge relaxation and slower redistribution of neutral salt are different observables.
For \(D_i=1.0\times10^{-9}\) m²/s and \(\kappa^{-1}=10\) nm, this local time is 100 ns, corresponding to an angular rollover scale \(1/\tau_D=10^7\) s⁻¹ or ordinary frequency about 1.6 MHz. Blocking electrodes in a cell of thickness \(L\gg\kappa^{-1}\) can display a slower charging time. Estimate its series resistance \(R=L/(\sigma_{\rm ion}A)\) and diffuse capacitance \(C\sim\epsilon\kappa A\) for one interface. Their product is of order \(L/(D_i\kappa)\). For \(L=100\) μm with the preceding parameters this is about 1 ms, orders of magnitude above the local bulk time. Two identical interfaces in series supply an extra numerical factor; finite reservoirs and unequal mobilities can introduce further scales.
A low-frequency impedance experiment interpreted as the equilibrium \(d\sigma/dV\) must therefore allow the actual circuit and cell to charge, not merely wait several local Debye times. Varying cell spacing helps distinguish a geometry-dependent charging time from an intrinsic screening-length change. This diffusion calculation and the static pressure calculation share the same \(\kappa\), giving independent checks on a physical fit to voltage, force and time-resolved measurements.
Check reservoir and continuum assumptions using actual particle numbers
The grand-canonical ion profiles implicitly allow the diffuse layers to draw particles from a large reservoir without changing the reservoir's chemical potentials. Whether this is reasonable can be checked with a dimensioned inventory. For a 1 mM monovalent salt, each species has about \(6.02\times10^{23}\) particles per cubic metre. A cell of area \(1\) mm² and depth \(100\) μm therefore starts with \(6.02\times10^{13}\) ions of each species. A surface charge density of \(1.0\) mC/m² on one plate amounts to \(6.24\times10^9\) elementary charges on that area. Even a conservative estimate in which each net countercharge requires one ion from the bulk uses only about \(10^{-4}\) of the available counterions.
Keep the same area and salt concentration but reduce the gap to 20 nm. Now only \(1.20\times10^{10}\) ions of each species occupy the cell initially. The same surface charge is comparable with half the inventory of one species. The remote-neutral-reservoir approximation is no longer automatically credible, especially if both walls attract counterions of the same sign. One must specify how ions and compensating charge can enter or leave, what the electrodes' chemical or electrical preparations enforce, and how much fluid actually belongs to the reservoir. An applied electrostatic boundary voltage fixes no ionic chemical potential by itself.
For a sealed cell write the equilibrium densities instead as \(n_\pm(z)=A_\pm \exp[\mp eV(z)/(k_BT)]\). The constants \(A_\pm\) must be chosen so that integrals of \(n_\pm\) over the physical volume equal the known numbers of each species. Substitution into Poisson's equation gives a coupled boundary problem with two additional global constraints. Adding a constant to \(V\) and appropriately rescaling \(A_\pm\) leaves the densities unchanged; electrical reference and chemical normalisation must be chosen consistently. A calculation holding both fixed bulk densities and exact sealed inventories can be overconstrained if diffuse layers hold appreciable salt.
The continuum approximation also makes a statement about scale. A cube of side one screening length near 10 nm at 1 mM holds roughly \(0.60\) ions of either species on average. This does not by itself invalidate a mean density for a large planar electrode, which averages over many lateral regions and thermal configurations. It does warn against interpreting the smooth one-dimensional density as a snapshot of a single nanometre-sized volume with a deterministic fractional particle. Force or voltage measurements with different lateral averaging areas can show quite different fluctuations even when their mean profiles follow the same equation.
As another self-check compare the predicted contact concentration with available molecular packing. The ideal theory gives
Starting from 1 mM, a surface potential near \(0.25\) V at 298 K would multiply concentration by roughly \(1.7\times10^4\), corresponding to tens of molar even before allowing room for solvent. A molecular model or a measured finite-size constitutive relation is then more appropriate for quantitative contact density. The failure is in extrapolating the dilute ideal entropy, not in Gauss's law or the electrostatic boundary condition. Source, solvent, reservoir and detector scales determine where the otherwise elegant analytic solution becomes an approximation to test.
Resolve a screening length
Compare the linear screened profile with a grid solution as the ratio of thickness to screening length grows. Separate failure to resolve the layer from failure of the linear material law.
How many excess ions, not just how much net charge?
Count the salt adsorbed in a planar diffuse layer
The total countercharge per area equals the negative surface charge. Separately calculate the excess number of ions of both signs over the neutral bulk value for a symmetric electrolyte at prescribed surface potential. Which quantity changes sign if the wall voltage reverses?
Derive and check the result
Define \(\Gamma=\int_0^\infty[n_+(z)+n_-(z)-2n_b]\,dz=2n_b\int_0^\infty(\cosh\psi-1)dz\). The integrand is nonnegative for either sign of wall voltage. For \(\psi_s>0\), substitute \(dz=-d\psi/[2\kappa\sinh(\psi/2)]\) from the first integral. Then \(\cosh\psi-1=2\sinh^2(\psi/2)\) makes the resulting integral elementary. The result, also valid at negative bias by symmetry, is \(\Gamma=(4n_b/\kappa)[\cosh(\psi_s/2)-1]\). It has units particles per area. The signed excess charge divided by elementary charge, in contrast, is
For positive surface charge the negative counterion excess and positive coion depletion follow by taking half the sum and difference of these two measurements. At small \(\psi_s\), the net charge excess is linear in voltage while \(\Gamma\) is quadratic: the two ion species redistribute in opposite directions before appreciable neutral salt adsorption appears. Reversing the bias swaps which species is enriched but leaves the total ion-number excess unchanged. Thus a mass-sensitive and a charge-sensitive measurement give complementary responses even in the same equilibrium model.
At \(\psi_s=2\),
The total excess count can be smaller than the magnitude of countercharge measured in elementary charges because some compensation occurs through removing coions rather than adding counterions. An optical concentration measurement that tracks only total dissolved ion count cannot be converted into net countercharge by multiplying by \(e\). Sampling both quantities, or calibrating the signal against the appropriate species, is needed to test the adsorption prediction. The derivation assumes the same dilute reservoir as the planar Poisson–Boltzmann solution and should not be applied unmodified to a cell with fixed small ion inventories.
Tutorial · infer a screening length and check the model
Use two potential measurements at finite bias
In a 298 K symmetric electrolyte, \(\tanh[eV(z)/(4k_BT)]\) decreases from 0.30 to 0.15 over 8.0 nm. Infer the screening length, and reconstruct the two physical voltages. Why is taking a raw voltage ratio slightly different?
Work through the solution
The transformed profile decays exponentially, so
Since \(4k_BT/e\simeq102.7\) mV, the voltages are \(102.7\operatorname{artanh}(0.30)=31.8\) mV and \(102.7\operatorname{artanh}(0.15)=15.5\) mV. Their physical ratio is about 0.488 rather than 0.500. Inferring a linear-log decay using only these points gives a biased length. Repeating at smaller voltages would test convergence towards the same result without assuming the nonlinear transformation.
Which capacitance was measured?
At low bias a diffuse model independently predicts 0.080 F/m² but a low-frequency measurement gives 0.050 F/m². Infer the compact capacitance of the ideal series model. What would make this inversion impossible with positive capacitances?
Work through the solution
From the reciprocal difference \(1/c_s=20-12.5=7.5\) m²/F we obtain \(c_s=0.133\) F/m². A measured capacitance larger than the predicted diffuse one would imply a negative reciprocal compact capacitance in this two-positive-series model. Check the normalisation area, frequency response, adsorption or additional parallel charging processes before assigning a negative parameter. To distinguish the two capacitances experimentally, vary reservoir concentration at fixed temperature and compare the predicted \(\sqrt{n_b}\) trend of the diffuse contribution with the remaining offset in reciprocal capacitance.
Further reading
Rotational and vibrational populations in a molecular gas
Statistical mechanics from microscopic counting to material response
A pressure thermometer and a calorimeter do not count molecular degrees of freedom in the same way. A dilute diatomic gas can retain nearly ideal pressure while its heat capacity changes appreciably as discrete internal levels become populated. Build the molecular partition function, derive the rotor and oscillator contributions, and infer temperatures from line populations without treating spectral intensity as a direct state count.
When a molecule's partition function factorises
Assume a dilute gas of stable diatomic molecules with weak interparticle interactions. Approximate one molecule's Hamiltonian by independent translational, rotational, vibrational and electronic parts. This requires a bond sufficiently stiff that rotation does not greatly alter vibrational energy and a temperature well below electronic excitations or dissociation when the electronic factor is treated as constant. If energies add and allowed states form a product, Boltzmann factors multiply. Thus \(q=q_{\rm tr}q_{\rm rot}q_{\rm vib}q_{\rm el}\), \(Z_N\simeq q^N/N!\) in the dilute classical translational regime. The logarithm converts this product into additive free energies, energies and heat capacities.
The translational factor \(V/\lambda_T^3\) provides the volume derivative and hence ideal pressure \(Nk_BT/V\). A volume-independent internal factor changes neither that derivative nor the associated translational equation of state. It does change entropy, chemical potential and calorimetry. The molar heat capacities satisfy \(C_p-C_V=R\) for a fixed-composition ideal gas, even when both vary strongly with temperature. Dissociation, chemical equilibration or significant intermolecular interactions can change the conclusion for the measured sample.
One danger is double-counting states. Angular momentum orientations belong to rotational degeneracy, oscillator quanta to vibration, electronic spin and nuclear exchange symmetry may constrain one another. A constant electronic degeneracy contributes an additive entropy \(Nk_B\log g\) but no internal energy or heat capacity at fixed level energies. A large heat capacity is evidence for energetically separated states becoming populated, not just for a large number of exactly degenerate states.
Derive the quantum rigid-rotor contribution
For a molecule of moment of inertia \(I\) about its centre of mass, rotational Hamiltonian is \(\hat L^2/(2I)\). Angular momentum eigenvalues are \(\hbar^2J(J+1)\), with \(2J+1\) projections at fixed \(J=0,1,\ldots\). Define rotational temperature \(\theta_r=\hbar^2/(2Ik_B)\). For distinguishable nuclei and a common nuclear spin factor omitted, the rotational sum and populations are
At high temperature the populated range contains many adjacent \(J\) values. Replacing the sum with an integral and substituting \(u=J(J+1)\) gives
Hence \(U_r\simeq Nk_BT\), \(C_{V,r}\simeq Nk_B\), the classical result for two independent rotational kinetic energies of a linear object. At low temperature only \(J=0\) and \(J=1\) matter. Their degeneracies and gap \(2k_B\theta_r\) give \(q_r\simeq1+3e^{-2\theta_r/T}\) and an exponentially vanishing heat capacity. Keeping the degeneracy three is essential for both its magnitude and the temperature of its turn-on.
For an illustrative heteronuclear rotor with \(\theta_r=85\) K, direct summation at 20 K gives \(q_r=1.00061\) and \(C_{V,r}=0.0440k_B\) per molecule. At 90 K the corresponding values are 1.471 and 1.063. At 300 K the heat capacity is 1.002. A small overshoot above the classical rotational value is possible during the crossover. A model that simply switches from zero to one classical degree contribution at \(T=\theta_r\) misses the entire smooth population redistribution and cannot predict line ratios.
The most populated \(J\) need not be zero, despite increasing energies, because the projection multiplicity increases with \(J\). Viewing the numerator as a smooth function of \(J\) gives \(J_{\rm peak}\simeq[\sqrt{2T/\theta_r}-1]/2\), to be checked against neighbouring integer values. The estimate is unreliable if it predicts only one or two populated levels. Computing a short discrete sum costs little and reveals its own truncation error through the final omitted weights.
Derive oscillator energy and heat capacity from a geometric series
Near its bond-length minimum approximate the interaction by a spring. With reduced mass \(m_r\) and angular vibration frequency \(\omega_v\), quantum energies are \(E_n=\hbar\omega_v(n+1/2)\). Define \(\theta_v=\hbar\omega_v/k_B\). Summing the resulting geometric series and differentiating gives
The zero-point term contributes energy but no heat capacity at fixed frequency. For \(x\ll1\) the heat capacity approaches \(k_B\) per independent vibrational mode, comprising kinetic and potential contributions. For \(x\gg1\) excitation is too costly and the heat capacity behaves as \(k_Bx^2e^{-x}\). A molecule can still vibrate quantum mechanically in its ground state while contributing virtually no vibrational heat capacity. A calorimeter measures sensitivity of mean energy to temperature and need not see the ground-state motion.
Take \(\theta_v=3000\) K. At \(T=300\) K the vibrational contribution is only \(0.00454k_B\), while at 1200 K it reaches \(0.609k_B\). Combining with the earlier rotor gives molar \(C_V\) approximately \(2.507R\) at 300 K and \(3.109R\) at 1200 K, assuming stable composition and frozen electronic structure. For acoustic measurements the ideal adiabatic ratio \(\gamma=(C_V+R)/C_V\) then decreases from about 1.399 to 1.322. An acoustic drive faster than vibrational relaxation can measure a frequency-dependent effective ratio because internal populations fail to remain equilibrated through a compression cycle.
Compare this single oscillator with the frequency distribution in the lattice heat-capacity plot
Nuclear exchange and the symmetry number
For a homonuclear molecule, rotating its classical orientation by half a turn end for end does not create a second distinct arrangement. In a high-temperature rotational count a symmetry number two therefore divides the distinguishable-nuclei rotor partition function once the compatible spin states are accounted for. Since this factor is constant with temperature it shifts entropy and chemical potential, but not the classical rotational energy or heat capacity. At low temperature it is important to treat actual quantum parity, not divide every level by two.
A homonuclear diatomic rotational wavefunction acquires a factor \((-1)^J\) under exchange of nuclei. The complete state also includes nuclear spin, electronic and vibrational parts. For ordinary molecular hydrogen in its electronic and vibrational ground state the protons are spin-half fermions. Antisymmetry pairs even \(J\) with the single antisymmetric spin singlet and odd \(J\) with the three symmetric triplet spin states. In true spin-conversion equilibrium the rotor sum uses weights one or three in addition to \(2J+1\). At temperatures large compared with rotational spacing, even and odd \(J\) sectors have nearly equal rotational sums and the equilibrium odd-to-even population ratio approaches three.
Conversion between spin species can be slow. A rapidly cooled sample may preserve its prepared fractions rather than attain spin equilibrium. Then compute separate parity-restricted partition functions for fixed species numbers, and average their thermal observables with the frozen proportions. Allowing the total odd fraction to relax yields a different heat capacity, including the energy liberated by conversion. Two experiments on chemically identical hydrogen can consequently report different heating curves because their preparation constrains different internal sectors.
Use intensities only after accounting for the instrument
An absorption line originating from level \(J\) has a strength depending on more than its population. Transition moment, polarisation, transition frequency, stimulated emission correction, instrument response and path length can all enter. Suppose line strengths and detector factors have been divided out to yield quantities proportional to level populations \(N_J\). Then a straight-line fit of \(\log[N_J/(2J+1)]\) against \(J(J+1)\) has slope \(-\theta_r/T\) for the simple heteronuclear model. Its intercept depends on total particle number, partition function and residual instrumental gain.
For \(\theta_r=10\) K, a measured corrected ratio \(N_2/N_0=2.00\) implies \(2=5e^{-60/T}\) and \(T=65.5\) K. Omitting the factor of five would make an upper population larger than the lower one appear incompatible with positive temperature. The inferred temperature assumes the rotational populations are equilibrated at one temperature; an optically pumped or rapidly expanding sample may have different rotational and translational distributions.
A plot over several \(J\) values can test whether one slope is adequate. Curvature may come from centrifugal distortion, line saturation, unresolved overlap, multiple temperatures or a wrong nuclear-spin degeneracy. Alternating residuals for even and odd \(J\) indicate a different physical problem from a smooth quadratic residual against \(J(J+1)\). Repeat with lower optical depth to isolate saturation, and use independently measured transition frequencies to fix level energies before fitting populations.
Recover molecular translation separately from internal structure
In a low-density molecular beam, the translational speed distribution is often easier to measure than the internal populations. For an equilibrium gas leaving a small opening into vacuum, the molecular flux is weighted by the normal velocity. Fast molecules reach and cross the aperture more frequently, so the distribution of speeds in the beam differs from the Maxwell speed distribution inside the reservoir. The mean translational energy of molecules in an effusive beam is \(2k_BT\), whereas the bulk mean is \(3k_BT/2\). This selectivity occurs even when rotational and vibrational populations remain canonical.
To derive the difference, start with the bulk velocity density proportional to \(e^{-mv^2/(2k_BT)}\). Write the outward normal speed as \(v\cos\theta\), integrate over the outward hemisphere and include the velocity-space shell factor \(v^2dv\). The resulting beam speed density is proportional to \(v^3e^{-mv^2/(2k_BT)}dv\), while the original bulk speed density has \(v^2\). Taking a ratio of Gaussian moments gives the stated energy. Comparing a beam energy to the wrong bulk prefactor would yield a temperature one third too high.
If the aperture is small compared with the mean free path and transition-detection efficiency is independent of speed after correction, internal state probabilities factor out of this flux weighting. A rotational population ratio can then report the reservoir temperature while the observed mean translational energy follows the effusive weighting. In a dense nozzle undergoing many collisions, expansion can cool translation and rotation differently. An inferred rotational and translational temperature disagreement is therefore not automatically bad calibration; first identify whether the beam is effusive, collisionally expanding or selectively detected.
As a bench example, a beam mean translational energy of 0.060 eV corresponds to approximately 348 K under effusion, using \(k_B=8.6173\times10^{-5}\) eV/K. Treating it as the bulk mean would give about 464 K. Compare against a population ratio from two corrected lines spanning \(80k_B\) kelvin and equal degeneracies. At the two temperatures the predicted ratios are about 0.795 and 0.842. Resolving this difference demands a relative line calibration appreciably better than six percent even though the two erroneous temperature interpretations differ by more than one hundred kelvin.
An isotope mixture reveals which spectral changes affect entropy
Compare two isotopic forms with the same approximate electronic potential surface. Bond force constant and equilibrium bond length then remain nearly unchanged while reduced nuclear mass changes. The harmonic vibrational frequency scales as \(m_r^{-1/2}\), while the rotational temperature scales as \(m_r^{-1}\). Consequently vibration and rotation respond differently to the same isotope substitution. Their shifts can jointly test whether two sets of spectral features genuinely belong to the same molecular carrier.
Suppose the reduced mass rises by a factor 1.21. A vibrational line at 2000 inverse centimetres moves approximately to 1818 inverse centimetres, and a rotational constant initially 2.00 inverse centimetres moves to 1.65 inverse centimetres. The vibrational characteristic temperature follows from \(hc\widetilde\nu/k_B\), about 1.4388 K per inverse centimetre. At room temperature the two vibrational gaps still greatly exceed thermal energy, so the vibrational heat capacity can remain small even though the spectral isotope shift is easy to resolve.
The zero-point energies nevertheless differ. For this vibrational example their difference is \(hc(2000-1818)/2\) per molecule, corresponding to about 131 kelvin in thermal units or 1.09 kJ/mol. Such offsets cancel within a fixed-species heat-capacity derivative but can matter to comparisons of chemical equilibrium or isotopic exchange. An analysis that discards all constant energy offsets independently in each molecular species can corrupt a reaction free energy unless it restores a consistent reference across reactants and products.
For a thermal entropy contribution from this one oscillator use \(S_v=k_B[(n+1)\log(n+1)-n\log n]\) with \(n=1/(e^x-1)\). This follows by inserting \(U_v\) and \(\log q_v\) into \(S=k_B\log q+U/T\); the zero-point contributions cancel exactly. Thus the measured isotope shift can change vibrational entropy via occupancy even while the zero-point offset itself contributes no entropy. It is helpful to evaluate all three quantities—energy difference, entropy difference and heat-capacity difference—rather than presume that a line shift must have the same thermodynamic role in each.
An internal relaxation time appears in frequency-dependent calorimetry
The equilibrium partition function assumes internal mode populations re-equilibrate on times short compared with the measurement. Model one slower internal degree by an internal energy \(U_s\) relaxing toward its equilibrium value at the instantaneous translational temperature \(T\), with \(\dot U_s=[U_{s,\rm eq}(T)-U_s]/\tau_s\). For a small oscillation around \(T_0\),
In the \(e^{-i\omega t}\) convention, the complex internal heat capacity and the total measured capacity including an instantaneous background \(C_f\) are
At low frequency the capacity is \(C_f+C_s\). At high frequency the slow internal energy cannot follow and the apparent in-phase capacity approaches \(C_f\). Its out-of-phase component peaks at \(\omega\tau_s=1\), where real and imaginary increments equal \(C_s/2\). The structure resembles dielectric relaxation because both arise from one relaxing state variable driven by a controlled sinusoid. It follows here from an explicit energy-exchange model and its assumptions.
Take a molar fast contribution \(2.50R\), slow equilibrium contribution \(0.60R\) and relaxation time 2 ms. The full equilibrium value is \(3.10R\). At about 79.6 Hz the real measured capacity is \(2.80R\) and the imaginary increment magnitude \(0.30R\). A heat pulse much shorter than two milliseconds initially raises the temperature as if the capacity were close to \(2.50R\), then energy flows into the internal mode. A slow calorimetric ramp can be perfectly consistent with a faster acoustic measurement that infers a smaller active capacity.
A sample container connected to a thermal bath produces its own complex temperature response even if molecular populations are always equilibrated. Disentangle those effects by calibrating the empty cell or an inert reference gas across the same frequency range, changing pressure to alter collision-mediated internal-relaxation time, and checking the predicted equilibrium limit from independently known level spacings. A mechanical resonance in the apparatus can be separated by varying cell geometry while keeping gas composition fixed. Fitting one imaginary peak to a molecular relaxation model without these controls does not uniquely determine the microscopic relaxation time.
How a line ratio and a calorimeter constrain degeneracies differently
Two groups report a low-energy excited manifold with dimensionless population ratio \(r=N_1/N_0\) at two temperatures. A single ratio determines only \(r=(g_1/g_0)e^{-\Delta/(k_BT)}\), so changing the assigned degeneracy changes the inferred gap. Taking the log ratio at two known temperatures removes a common degeneracy factor. The slope of \(\log r\) against \(1/T\) is minus the gap in kelvin, and the intercept is the log degeneracy ratio if the line-strength calibration and equilibrium assumptions hold.
For illustrative values \(r=0.300\) at 100 K and \(r=0.949\) at 200 K, the log change is approximately 1.152. Dividing by the inverse-temperature change magnitude 0.005 per kelvin gives \(\Delta/k_B\simeq230\) K. Inserting the first ratio gives \(g_1/g_0\simeq3.00\). The same two-manifold model predicts a dimensionless heat capacity \(x^2r/(1+r)^2\) per molecule. At 100 K it is about 0.94, a separate calorimetric prediction independent of the absolute number of detected photons.
A third temperature materially improves the test. An unseen nearby manifold or a line strength that changes with instrumental settings may fit two exact population ratios but produce curvature and excess heat capacity elsewhere. Spectroscopy resolves ordered energy differences while calorimetry sums energy variances over all accessible states. Their combination offers more information than adding further precision to one population measurement under the same ambiguous degeneracy assumption.
Compress a gas without pretending its heat capacity stays constant
A reversible adiabatic compression is often summarised by a fixed exponent \(\gamma\). That power law assumes temperature-independent heat capacities along the path. Molecular populations give a direct case where the exponent changes. For an ideal gas at fixed composition,
Along a reversible adiabatic path set the sum to zero and integrate. The volume ratio is determined by an integral of measured or calculated \(C_V(T)/T\), not by a universal constant exponent across every temperature.
As an illustrative calculation approximate translation and fully active rotation by \(C_V=2.5Nk_B\) plus one harmonic vibrational mode with \(\theta_v=3000\) K. Heating from 300 to 1200 K at constant entropy gives a volume contraction factor from the fast degrees alone of \(4^{2.5}=32\). The vibrational entropy difference adds another factor \(e^{\Delta S_v/(Nk_B)}\). At 300 K the oscillator entropy is only about \(0.00050k_B\), while at 1200 K it is about \(0.309k_B\). The combined estimate requires \(V_i/V_f\simeq43.6\), a substantially larger compression than the frozen-vibration approximation predicts.
This comparison assumes ideal gas throughout and no dissociation, conditions to be checked in a real large compression. It nevertheless identifies the mechanism: part of the compression work goes into levels that were effectively inactive initially. Using the final high-temperature heat capacity across the whole path would err in the opposite direction by assigning that energy storage to the low-temperature portion as well. The entropy integral correctly weights each temperature interval by its actual internal population response.
A numerically stable solution can avoid differentiating noisy calorimetry. Integrate the entropy increment from tabulated heat capacities in the log-temperature variable. Compare an adaptive integral with a refined straightforward grid, paying particular attention to the rotational or vibrational crossover scale. Alternatively compute endpoint entropies from partition functions when an independently justified spectral model exists. Agreement between calorimetric integration and spectroscopy-derived endpoint entropy checks both assignments without demanding exact agreement of noisy pointwise derivatives.
Experimental pressure also checks the endpoint calculation independently. After equilibration, the ideal equation of state predicts \(p_f/p_i=(T_f/T_i)(V_i/V_f)\), approximately 174 for this idealised path. Finite heat leakage or a pressure-dependent nonideality can change that value. A rapid adiabatic compression can be irreversible even if little heat leaves the chamber, and then the measured entropy can increase. Distinguish a reversible reference calculation from an actual rapid piston protocol before using a mismatch to infer missing molecular levels.
An independent isotropic acoustic test at a fixed initial temperature infers \(\gamma\) from the small-amplitude sound speed \(c_s^2=\gamma RT/M\), where \(M\) is molar mass. At fixed molecular mass a decrease of \(\gamma\) from 1.40 to 1.32 at the same temperature would lower sound speed by the square root of their ratio, roughly three percent. That comparison must truly hold temperature fixed: the large direct thermal dependence of sound speed can easily exceed the internal-mode effect. Frequency-resolved acoustics can see part of a vibrational mode freeze dynamically while equilibrium spectroscopy still predicts its population. Record both phase velocity and acoustic attenuation if the aim is to identify a relaxation time. Across the relaxation band, dispersion without the corresponding dissipative response should prompt a check of transducer phase calibration and acoustic boundary conditions.
Read the rotational level spacing from thermal energy storage
Sum the discrete levels of a linear rotor and compare the heat capacity with equipartition as temperature rises.
Tutorial · Identify a rotor inertia from spectral spacing
For a heteronuclear linear rotor the lowest pure rotational transition has ordinary frequency 120 GHz. Infer \(\theta_r\), the moment of inertia and the expected \(J=1\) to \(J=0\) population ratio at 10 K. How could an isotope substitution test the interpretation?
Use the transition gap and keep angular and ordinary frequency distinct
The gap is \(2k_B\theta_r=h\nu\), so \(\theta_r=2.88\) K and \(I=\hbar^2/(2k_B\theta_r)=1.40\times10^{-46}\) kg square metres. The population ratio is
The upper manifold contains more molecules even though each of its levels has lower individual Boltzmann weight. Increasing reduced mass at nearly fixed bond length increases \(I\), reducing the transition frequency approximately inversely with reduced mass. A vibrational frequency from the same spring would scale instead with inverse square root of reduced mass.
Tutorial · Infer an excitation temperature from calorimetry
A gas of linear molecules has molar \(C_V=2.91R\) at a temperature where translation and rotation contribute \(2.50R\). Neglect electronic excitation and estimate the characteristic temperature of a single harmonic vibration in units of measurement temperature. Would a measured \(C_p\) be usable unchanged?
Invert the oscillator contribution and verify its feasible range
The remaining \(0.41R\) lies between zero and the one-mode classical limit \(R\). Solve \(x^2e^{-x}/(1-e^{-x})^2=0.41\) on positive \(x\). At 3.0 it is 0.496 and at 3.5 it is 0.393, placing the root near 3.41. Thus \(\theta_v\) is about 3.41 times measurement temperature. Use several temperatures to verify the characteristic value and frozen-composition model. For ideal gas at fixed composition, subtract \(R\) from \(C_p\) before applying this constant-volume balance. Latent processes, reaction and internal relaxation would require an extended model.
Tutorial · Distinguish equilibrium hydrogen from a frozen spin mixture
At low temperature only \(J=0\) in the even sector and \(J=1\) in the odd sector contribute. Use \(\theta_r=85\) K and \(T=30\) K. Estimate the equilibrium odd fraction and compare the energy stored in a sample frozen at a three-quarter odd fraction, measured relative to the common lowest even state.
Normalise both sectors and identify the energy released on conversion
The relative weight of \(J=1\) is \(3(2J+1)e^{-170/30}=0.0311\); the even ground state has weight one. The equilibrium odd fraction is approximately 0.0302. A frozen sample at odd fraction 0.75 stores about \(0.75(170)k_B=127.5k_B\) kelvin of rotational energy per molecule, versus about \(5.1k_B\) kelvin for equilibrium. The excess expressed per mole is roughly \(R(122.4\,{\rm K})=1.02\) kJ/mol.
The frozen low-temperature heat capacity can be small even while substantial energy remains trapped in the odd sector. A calorimeter monitoring a slowly converting sample measures time-dependent heat release, not simply the derivative of a stationary restricted partition function. Measure the spin fraction independently or vary equilibration time before comparing its heat curve with an equilibrium prediction.
Cambridge Statistical Physics · molecular partition functions and internal degrees of freedom
Bose condensation, dimensionality and a finite trap
Statistical mechanics from microscopic counting to material response
Cooling a gas of identical bosons can populate a single orbital macroscopically. The temperature at which that occurs depends on the low-energy density of states, not simply on the energy needed to put one particle in the first excited level. Compare a uniform box with a harmonic trap, estimate a condensate fraction and design an imaging test that separates occupation of a mode from a narrow but entirely thermal cloud.
Derive the occupation before approximating the density of states
A single noninteracting bosonic orbital of energy \(\epsilon_j\) may contain \(n_j=0,1,2,\ldots\) particles. In contact with a reservoir of temperature \(T\) and particle chemical potential \(\mu\), its grand partition factor is the geometric series \(\sum_n e^{-\beta n(\epsilon_j-\mu)}\). Convergence requires \(\mu<\epsilon_0\), where \(\epsilon_0\) is the ground energy. Differentiation gives mean occupancy \(1/[e^{\beta(\epsilon_j-\mu)}-1]\). Shift the energy origin to \(\epsilon_0=0\), so fugacity \(z=e^{\beta\mu}<1\). For a fixed mean particle number solve \(\sum_j\langle n_j\rangle=N\).
As temperature falls, the distribution narrows toward low energies and \(\mu\) generally rises toward the ground energy. It does not cross that energy in an equilibrium ideal finite gas. A large mean ground-state population corresponds to \(1-z\) of order \(1/N_0\). Once \(N_0\) is comparable to the total, replacing that single low-lying orbital by a continuum density of states can erase the very population of interest. Separate it before approximating the excited states.
A bosonic occupancy of one per quantum state is not an upper limit. At classical high temperature typical occupation of each relevant orbital is small and \(n_j\simeq ze^{-\beta\epsilon_j}\). The statistical difference from a dilute classical gas becomes appreciable when the thermal de Broglie volume is comparable to the volume per particle. This criterion indicates growing exchange effects; the existence of a finite-temperature condensation transition additionally depends on dimension, dispersion and trapping geometry.
Count the three-dimensional excited particles
Use periodic boundary conditions in a large cubic box with side \(L\). Allowed wavevectors occupy cells \((2\pi/L)^3\) in reciprocal space. For one spin species, counting the spherical shell and substituting \(\epsilon=\hbar^2k^2/(2m)\) gives an excited-state density proportional to \(V\sqrt\epsilon\). Expand \(1/(z^{-1}e^x-1)=\sum_{\ell\ge1}z^\ell e^{-\ell x}\) before evaluating the radial Gaussian integrals. In terms of the thermal wavelength and Bose functions \(g_s(z)=\sum_{\ell\ge1}z^\ell/\ell^s\), the result is
Pressure follows from the grand potential or the kinetic virial identity in a uniform nonrelativistic gas. The ground state at zero momentum contributes no extensive kinetic energy or pressure in the thermodynamic continuum expression. It can nevertheless carry a macroscopic particle number. These formulas describe an ideal gas: interactions can add pressure and shift excitations even at very low temperature.
The series \(g_{3/2}(1)=\zeta(3/2)=2.6124\) converges. At a fixed temperature the excited population per volume therefore has a maximum. At fixed total density \(n\), once this maximum falls below \(n\), the remaining particles accumulate in the ground orbital. Equating the two numbers defines the bulk critical temperature, and the below-transition condensate fraction follows:
For a single-state gas of atoms with mass 87 unified atomic mass units at density \(10^{20}\) per cubic metre, \(T_c\simeq398\) nK in this ideal box model. At \(0.70T_c\) the predicted condensate fraction is 0.414. Doubling density raises \(T_c\) by a factor \(2^{2/3}=1.587\). If imaging calibration rescales density but the reported temperature is independent, such a shift can move an inferred reduced temperature significantly. A finite trap or several spin components must be modelled before turning these example numbers into a laboratory calibration.
Why a uniform two-dimensional ideal gas is different
For free quadratic dispersion in \(d\) dimensions the density of states per volume scales as \(\epsilon^{d/2-1}\). As \(\mu\to0^-\), occupancy behaves like \(k_BT/\epsilon\) at low energy. The excited-population integral near its lower limit therefore behaves as \(\int_0 \epsilon^{d/2-2}d\epsilon\). It converges only for \(d>2\). A uniform three-dimensional ideal gas saturates; in two dimensions the integral diverges logarithmically and in one dimension even more strongly. In the infinite uniform two-dimensional ideal gas at fixed density a finite positive temperature does not require a macroscopic ground occupation.
The two-dimensional integral can be evaluated explicitly. Per unit area \(n_{2D}=-\lambda_T^{-2}\log(1-z)\). At phase-space density \(n_{2D}\lambda_T^2=5\) this gives
In the formal grand description the mean ground occupation would be about 147 for this chemical potential, large on an atomic scale but still independent of total area at fixed density in the thermodynamic limit. Enlarging a system is how one distinguishes a finite prominent occupation from an extensive one.
A strictly finite box has discrete energies, so even a nominally two-dimensional sample can show a finite-size crossover with a narrow central state. Gapped transverse excitations may also make a nominally planar cloud effectively three-dimensional at sufficiently high temperature. Interacting two-dimensional fluids can exhibit a vortex-mediated transition involving long-range phase correlations of a different kind. The ideal uniform density-of-states argument neither derives nor rules out that interacting transition.
Count a harmonic trap in phase space
In a three-dimensional harmonic trap with frequencies \(\omega_x,\omega_y,\omega_z\), subtract the zero-point ground energy. Excited energies are \(\hbar(\omega_xn_x+\omega_yn_y+\omega_zn_z)\) with nonnegative integers. When \(k_BT\) exceeds all the level spacings by a large factor, approximate the number of states below energy \(\epsilon\) by the volume of a positive octant tetrahedron in the three occupation-number coordinates. Its derivative yields
Condensation now gives
In a trap with geometric mean frequency 100 Hz and \(N=10^5\), the ideal estimate is 210 nK. At 0.70 of this trap-specific critical temperature the condensate fraction is 0.657, appreciably greater than the 0.414 box result at the same reduced temperature. Mixing a trap density of states with a homogeneous critical formula cannot be repaired by inserting one arbitrarily chosen cloud volume.
For a harmonic trap in \(d\) dimensions the low-energy density behaves as \(\epsilon^{d-1}\). Excited-state saturation in this semiclassical trapped model already occurs for \(d>1\). The changed criterion arises because a higher-energy particle also explores more physical space in the trap. The thermodynamic limit must be specified: holding all trap frequencies fixed while adding arbitrarily many particles changes the central density. A conventional trapped limit sends the trap frequencies to zero with a suitable combination such as \(N\bar\omega^3\) fixed.
Connect a narrow peak to occupation and spatial coherence
After an ideal noninteracting cloud is released, a particle initially at \(\mathbf r_0\) and momentum \(\mathbf p\) reaches \(\mathbf r_0+\mathbf p t/m\). At long expansion times the position distribution maps approximately to momentum distribution after accounting for initial cloud size. A condensate occupying one trap orbital can therefore produce an extended but narrow component in a momentum image superposed on a broader thermal distribution. Ballistic expansion length, resolution and interaction-driven expansion all affect the observed width.
For the 87-unit-mass example at 200 nK a one-axis thermal velocity scale is
After 20 ms its thermal contribution to one-axis rms width is about 87 micrometres. A point-spread width of ten micrometres is a small correction for this broad part but can dominate a genuinely much narrower central component. Fit integrated particle number and the spatial response of each component. A Gaussian peak height alone increases when the same number of atoms occupies a narrower instrument function.
A more fundamental criterion uses the one-particle density matrix. Its eigenvalues are orbital occupations; a condensate has an eigenvalue proportional to the total number as the appropriate system size grows. Interference measurements of first-order coherence or occupation scaling over different atom numbers can test this picture. Condensation is not identical to zero viscosity or a critical flow speed. An ideal uniform quadratic gas has low-energy excitations with arbitrarily small energy per momentum and does not by itself predict the finite critical speed of an interacting superfluid.
Solve the discrete number equation before passing to a continuum
A small cold gas in a box is an excellent numerical test because the discrete energy levels, their degeneracies and their individual occupancies are known. For a periodic cube with ground energy zero, write its excited energies as \(\epsilon_{\mathbf j}=\epsilon_L(j_x^2+j_y^2+j_z^2)\), where \(\epsilon_L=2\pi^2\hbar^2/(mL^2)\). The first shell has six states, the next twelve and the third eight. Replacing each shell by one level without its vector degeneracy artificially drives particles into the ground state.
For a specified finite number \(N\), solve \(N=\sum_{\mathbf j}[e^{\beta(\epsilon_{\mathbf j}-\mu)}-1]^{-1}\) with a chemical potential strictly below zero. This is a monotone root problem: as \(\mu\) goes from minus infinity toward zero the sum grows from zero without bound owing to the ground state. Use an energy cutoff well above the available thermal energy and estimate the omitted tail, increasing the cutoff to check convergence. Near zero, evaluate \(e^x-1\) with a numerically stable small-argument function. A naive evaluation of \(e^x-1\) can erase the tiny denominator representing a macroscopically occupied orbital.
A useful artificial example has \(\beta\epsilon_L=2\) and a mean ground occupation of 99. This fixes \(z=99/100=0.99\). Each of the six first-shell levels contains on average \(1/[e^2/0.99-1]=0.1548\) particles, contributing 0.929 in total. The twelve next-shell levels at \(4k_BT\) contribute another 0.222 together. Their combined occupation is already greater than one even though every individually excited orbital is weakly occupied. A code can compare an explicit vector enumeration with a shell-degeneracy table and verify exact agreement for the same cutoff.
The finite grand-canonical solution fixes mean \(N\), not the integer count in each run. A canonical simulation with exactly \(N\) can yield similar mean populations in an appropriate large system but very different ground-state number fluctuations. In the grand ensemble one isolated orbital has a geometric number distribution with variance \(\langle n\rangle(1+\langle n\rangle)\). A mean ground population of 99 then corresponds to a standard deviation close to the mean. A sealed sample of exactly 100 atoms cannot physically realise this unbounded distribution. Comparing its observed condensate fluctuations to the independent grand-canonical orbital formula without enforcing number conservation would be misleading.
The heat capacity sees the excited cloud, not a hidden latent heat
Below the bulk transition in a uniform ideal gas the fugacity tends to one. The energy expression becomes
which grows as \(VT^{5/2}\). At fixed box size and fixed total atom number, the excited fraction adjusts with temperature while the ground state supplies or accepts the remaining particles. Differentiating gives
Dividing by the total particle count gives a heat capacity per particle proportional to \((T/T_c)^{3/2}\).
At the critical temperature just below the transition, the coefficient per particle is \(15\zeta(5/2)/(4\zeta(3/2))\simeq1.93k_B\). At half that temperature it is about \(0.681k_B\). The energy and entropy are continuous at the uniform ideal transition; saturation of the excited population is not the same as a first-order phase change with a latent heat between two bulk densities. In the harmonic trap the different density of states yields a different power and a different shape of the heat-capacity anomaly. Thermodynamic measurements can therefore help distinguish trap geometry when imaging alone is ambiguous.
A calorimetric estimate of temperature often assumes the gas can re-equilibrate after a controlled energy pulse. In a perfectly noninteracting isolated gas, occupation numbers of stationary orbitals do not redistribute by themselves. Weak collisions, a reservoir or an explicit thermalisation protocol must establish equilibrium. The ideal gas can be an excellent equation-of-state model while weak interactions remain necessary for reaching that state on laboratory timescales. If the waiting time after a pulse is shorter than the redistribution time, substituting the equilibrium heat capacity into \(\Delta T=\Delta U/C\) may falsely imply anomalous heating.
One practical diagnostic is to vary the waiting time while monitoring both the broad-wing kinetic temperature and central fraction. Thermal equilibrium predicts a definite relation between those two quantities at fixed total number and geometry. A lagging central fraction together with apparently stable wings suggests a slow redistribution process or atom losses. Repeating with matched final number and with independently calibrated detection efficiency is more discriminating than fitting temperature from the central peak alone.
Detect bosonic bunching without assuming a condensate
Occupation can also be probed through intensity or number correlations. For a single thermal bosonic mode with geometric distribution, the normally ordered second-order correlation is
A coherent-state Poisson number distribution gives one. A precisely fixed number \(n\) gives \(1-1/n\). These statements concern the statistics of the selected mode and the preparation. They must not be read as a universal test in which every condensed cloud has the same value under every ensemble or detection geometry.
In a detector pixel collecting \(M\) independent identically populated thermal modes, the mean total number is \(M\bar n\), variance \(M\bar n(1+\bar n)\). Substituting into the factorial moment gives
Ten unresolved thermal modes therefore give 1.10 rather than 2, even though each separately bunches fully. Finite temporal averaging, velocity-bin width and spatial point spread can increase the effective number of collected modes. A near-unity measured correlation does not by itself demonstrate that the gas has developed a macroscopically coherent orbital.
Why use a factorial moment? For independent shot noise the ordinary second moment contains a self-count term \(\langle n\rangle\). Subtracting it isolates pair coincidences between distinct particles. A detector that cannot distinguish simultaneous events may preferentially drop exactly those pairs, creating artificial suppression. Two independent detection channels after a calibrated splitter can estimate coincidences without a single-pixel dead-time bias, provided cross talk and timing jitter are characterised.
A useful exercise varies both integration width and total atom number. A correlation excess falling with broader detection windows supports collection of multiple unresolved thermal modes. A central mode whose occupancy remains a fixed fraction as the whole gas grows supplies different information. Neither test replaces a correctly modelled spatial coherence measurement, yet together they constrain interpretations that can fit one mean momentum image.
How a number solver reveals its own near-critical sensitivity
At fixed temperature, derivative of total ideal boson occupation with respect to chemical potential is \(\beta\sum_j n_j(1+n_j)\). A highly occupied lowest orbital can dominate the derivative even if the measured energy is primarily carried by the excited states. Hence a small error in chemical potential can produce a large error in number while barely changing calculated energy. A solver that stops when energy converges may report the wrong condensate fraction.
For a mean ground occupation \(10^4\), its chemical-potential distance below the lowest level is \(k_BT\log(1+10^{-4})\), approximately \(10^{-4}k_BT\). A shift in that tiny gap by ten percent changes the occupancy by roughly ten percent while leaving the apparent fugacity close to one to four significant digits. Track chemical potential relative to the exact ground energy and report particle-number residual directly. Conversely, a small absolute error in a reported fugacity near saturation is not by itself evidence for a large uncertainty in the empirically counted atom number.
Finally, compare continuum estimates on several finite boxes at the same density. The leading discrepancy often comes from low discrete modes rather than the high-energy cutoff. Refine the low-energy calculation and the tail independently: enumerate a set of low shells exactly and replace only the dense upper spectrum by an integral. Check for double counting at the matching cutoff. An apparently excellent bulk critical temperature at one size can otherwise result from two cancelling approximations with different size dependence.
Infer a box density from a harmonically confined thermal cloud
Far from degeneracy a harmonically confined gas has classical spatial density \(n(\mathbf r)=n(0)e^{-V(\mathbf r)/(k_BT)}\). For an isotropic trap \(V=m\omega^2r^2/2\), each coordinate is Gaussian with variance \(s^2=k_BT/(m\omega^2)\). Normalising its full three-dimensional density gives
An absorption image generally measures a column integral, whose central value is \(N/(2\pi s^2)\), with units per area. Substituting this column density into a volumetric condensation criterion is dimensionally incorrect.
For \(N=10^5\), mass 87 unified atomic units, ordinary trap frequency 100 Hz and temperature 400 nK, the classical one-axis size is about 9.85 micrometres. The inferred central volume density is \(6.65\times10^{18}\) per cubic metre. The phase-space density estimate \(n(0)\lambda_T^3\) is about 0.17; the classical profile is therefore a useful leading reference rather than a precision model at all radii. A ten-percent systematic underestimate of width inflates the inferred central density by about 37 percent because width enters cubed.
Near the transition the local-density approximation replaces the constant chemical potential by \(\mu-V(\mathbf r)\) inside the uniform-gas density function. This preserves the global chemical potential while reducing local effective fugacity away from the centre. Integrating the resulting local density over position recovers the harmonic-trap density-of-states counting in the semiclassical regime. A central phase-space density approaching the uniform saturation value can therefore coincide with a trap-wide critical atom number governed by \(\zeta(3)\), not \(\zeta(3/2)\). These statements use different spatial integrations and are consistent.
A practical reconstruction fits widths along multiple axes and includes known imaging point spread. For a Gaussian image convolved with a Gaussian response, variances add. A measured width of 10.0 micrometres and known response width 3.0 micrometres imply true width 9.54 micrometres, changing a cubed-density estimate by roughly fifteen percent. A narrow condensate component often has a non-Gaussian profile or a size comparable with the resolution, so the simple Gaussian deconvolution should not be applied indiscriminately to both components.
Compare inferred atom counts over increasing fields of view. Truncating broad thermal wings undercounts the thermal population and makes the apparent condensed fraction too large, particularly near onset. Independent normalisation from the complete cloud and fits to held-out outer regions help separate this effect from an actual change in the fraction occupying the lowest orbital.
There is a useful contrast with a single-occupancy adsorption site. Its occupation variance at mean fraction \(f\) is \(f(1-f)\), whereas one thermal Bose orbital at mean occupation \(\bar n\) exhibits \(\bar n(1+\bar n)\). At mean 0.50 these are respectively 0.25 and 0.75. The sign difference expresses whether multiple occupancy is excluded or enhanced. Vary the chemical potential in the single-site experiment and compare the response-to-noise identity before evaluating the Bose derivative on paper. Both obey the same grand-ensemble fluctuation formula, yet their number variances differ at the same mean because the allowed microscopic configurations differ. An observed sub-Poisson count can alternatively arise from detector dead time, and multiple unresolved thermal modes reduce bunching, so the ideal comparison is strongest for calibrated single-mode or single-site measurements.
Compare the measured single-site fluctuation law with the Bose orbital variance
Count the excited atoms in a trapped gas
Change atom number and confinement frequency. Compare the discrete level sum with the continuum estimate and relate the difference to the density of states.
Tutorial · Check what changes during an adiabatic box expansion
Below the transition a dilute ideal condensed box gas expands slowly and reversibly with fixed \(N\). Determine how temperature and condensate fraction vary with volume. Would an isothermal expansion give the same outcome?
Use the entropy and critical-temperature scalings together
Below transition the bulk chemical potential tends to zero. Since \(U=3pV/2\), \(S=(U+pV-\mu N)/T\) is proportional to \(VT^{3/2}\) for the saturated excited gas. At constant entropy \(T\propto V^{-2/3}\). The box critical temperature at fixed \(N\) has exactly the same volume dependence, so \(T/T_c\) and the leading condensate fraction stay constant. In an isothermal expansion \(T_c\) falls while \(T\) stays fixed, decreasing condensed fraction and eventually exhausting it. The result rests on ideal-gas equilibrium and reversible expansion; a sudden opening into a second container is not that adiabatic path.
Tutorial · Determine whether a trap can be treated as three-dimensional
An anisotropic harmonic trap has ordinary frequencies 40, 40 and 8000 Hz at a measured \(T=100\) nK. Compute the spacings expressed as temperatures and assess using the three-dimensional semiclassical trap formula. Propose a consistent calculation near the dimensional crossover.
Identify which quantum numbers are actually sampled
Using \(h/k_B=4.799\times10^{-11}\) K s, the level spacings are 1.92, 1.92 and 384 nK. Many transverse levels in the soft directions are populated, whereas a single quantum along the tight axis costs nearly four thermal energies. A three-dimensional integral over all three quantum numbers would overcount accessible low-energy states. Keep the tight-axis sum discrete while approximating the two soft directions semiclassically. Separate the exact global ground orbital from that hybrid excited-state count before solving for chemical potential at fixed total number.
At a few hundred nanokelvin the next tight-axis branches start to contribute appreciably. Observe widths or occupation across a temperature scan instead of announcing a fixed dimensionality based solely on trap shape. The model should recover a two-dimensional low-temperature limit and cross over smoothly toward three-dimensional counting when all spacings become small relative to thermal energy.
Tutorial · When is a ground-state peak extensive?
Three otherwise comparable measurements at fixed estimated areal density and temperature use planar boxes of areas in the ratio one, two and four. They yield approximately the same central-state population of 150 atoms but total numbers 3000, 6000 and 12000. Compare with the ideal planar fugacity estimate above and explain what conclusion follows.
Examine scaling and the resolution of a single mode
The fractions are 0.050, 0.025 and 0.0125, falling inversely with area. This is consistent with a highly occupied but nonextensive single level at fixed fugacity near 0.993. A homogeneous three-dimensional bulk condensate at fixed reduced temperature would instead have approximately constant fraction under the appropriate volume scaling. Absolute occupation larger than one is insufficient to distinguish the two regimes.
Confirm that the same experimentally defined central window isolates a single momentum mode as the box size changes. Allowed wavevector spacing shrinks with system size, so a fixed physical momentum aperture can sum an increasing number of levels. Correct for finite resolution, compare the complete momentum distributions and control interactions before treating the simple size dependence as a proof about the thermodynamic limit.
Cambridge Statistical Physics · ideal quantum gases and Bose condensation
Degenerate fermions, heat and magnetic response
Statistical mechanics from microscopic counting to material response
An ordinary metal at room temperature contains electrons with characteristic kinetic energies of several electronvolts, yet its electronic heat capacity is small compared with the classical estimate. Identify which electrons respond to heat, compression and a weak magnetic field. Then compare three independent ways to determine a density of states and investigate what a disagreement would mean.
Count states and fill them with fixed particle number
A spin-half noninteracting fermion orbital of specified spin can be empty or occupied once. Its grand partition factor is \(1+e^{-\beta(\epsilon-\mu)}\), giving mean occupation \(f=1/[e^{\beta(\epsilon-\mu)}+1]\). At zero temperature the occupations form a step. In a uniform three-dimensional box, fill both spin states at each wavevector up to radius \(k_F\). Counting reciprocal-space cells gives
Here \(D\) counts both spin projections per unit energy for the whole sample. It obeys \(D(E_F)=3N/(2E_F)\). Distinguish this density from a density per volume or per spin, since factors of volume and two matter in susceptibility and specific heat. A lattice band may have a quite different dispersion and density of states; simply substituting the vacuum electron mass is a model to be tested for a given solid.
At \(n=8.5\times10^{28}\) electrons per cubic metre and the free electron mass, \(E_F=7.05\) eV, \(T_F=81{,}800\) K and \(v_F=1.57\times10^6\) m/s. Room temperature is only 0.00367 of this Fermi temperature. The gas is highly degenerate despite not being near absolute zero in everyday terms. These speeds are random occupied-state group velocities, with equal positive and negative contributions to net current in equilibrium. A metal with no applied field does not transport its entire electron density in one direction at that speed.
Integrating \(E D(E)\) to the Fermi level gives
Volume differentiation at fixed \(N\), using \(E_F\propto V^{-2/3}\), gives pressure \(p_0=2nE_F/5\). Thus a nonzero kinetic pressure remains at zero temperature. It describes the electron subsystem and is balanced by other forces in a neutral solid. It is not the pressure one could read by attaching an ordinary fluid pressure gauge to a solid metal specimen.
Derive the low-temperature expansion without losing particle conservation
For a smooth function \(H(E)\), compare \(\int H(E)f(E)\,dE\) with its zero-temperature integral up to \(\mu\). Write the difference as contributions above and below \(\mu\), substitute \(x=|E-\mu|/(k_BT)\) and use \(1-f(\mu-k_BTx)=f(\mu+k_BTx)\). The difference then samples \(H(\mu+k_BTx)-H(\mu-k_BTx)\), so only odd derivatives of the smooth function contribute. Integrating the leading term gives
This expansion assumes the Fermi level is many thermal energies above the bottom and that \(H\) varies smoothly through the thermal shell. Near a band edge or a very narrow density-of-states peak the assumption can fail even when temperature looks modest relative to some larger energy. Direct numerical quadrature retaining the correct band limits and a particle-number solution for \(\mu\) is then preferable.
For fixed \(N\), use \(H=D\) and demand that the result remain its zero-temperature value. The chemical potential shift is \(\delta\mu=-(\pi^2/6)(k_BT)^2D'(E_F)/D(E_F)\). For \(D\propto\sqrt E\) it becomes
Next use \(H=ED(E)\) in the energy integral. Its \(T^2\) contribution from the shifted upper limit cancels the part involving \(E_FD'\), leaving
The typical number of thermally active state slots scales as thermal energy times \(D(E_F)\). This produces a heat capacity linear in \(T\), not proportional to the entire electron count times a temperature-independent classical factor. At 300 K in the example the electronic heat capacity is \(0.0181Nk_B\). Its volume coefficient \(C_V/(VT)\) is about 70.8 J per cubic metre per kelvin squared. A much larger lattice contribution may hide it at room temperature. At low temperature fit \(C/T\) against \(T^2\) to separate an electronic intercept from a Debye \(T^3\) lattice term where these asymptotic laws are valid.
Compare the conserved-number chemical potential with the Sommerfeld approximation
Apply a weak field to the spin populations
For a weak uniform magnetic induction \(B\) neglect orbital coupling temporarily. Spin moments of magnitude \(\mu_B\) acquire energy offsets \(\mp\mu_BB\) for their two alignments in the simple electron model. At fixed total density and zero temperature, one spin population gains states at its Fermi surface and the other loses an equal number to first order. The density of states per spin is \(D(E_F)/2\); the difference in population is thus \(D(E_F)\mu_BB\). Magnetisation is this difference times \(\mu_B/V\), giving the weak-field SI susceptibility
We have used \(B\simeq\mu_0H\) in a weakly magnetic macroscopic state and ignored demagnetising corrections. The result is approximately temperature-independent for a strongly degenerate smooth band. Independent localised moments would give a Curie susceptibility proportional to inverse temperature in their high-temperature weak-field regime. A small low-temperature upturn can therefore come from a small concentration of local moments even when most carriers remain itinerant.
For the earlier density \(\chi_P\simeq1.22\times10^{-5}\). A field of 1.0 T splits spin energies by \(2\mu_BB=0.116\) meV, vastly smaller than 7.05 eV. The fractional spin imbalance is \(3\mu_BB/(2E_F)\simeq1.23\times10^{-5}\). Tiny spin imbalance can produce a reproducible measurable magnetisation because the sample contains a macroscopic number of electrons. Linear susceptibility should be tested by field reversal. A hysteretic or saturating impurity background cannot be removed reliably by fitting one positive-field point.
At finite temperature the response replaces sharp \(D(E_F)\) by \(\int D(E)[-\partial f/\partial E]dE\) at the corresponding chemical potential. The negative occupation derivative integrates to approximately one and has width several thermal energies. This Fermi-window average is another reason the susceptibility and heat capacity emphasise nearby states rather than the entire filled band. Their precise kernels differ, so a rapidly varying band structure or interactions can alter their ratio.
Infer the same states through a density response
At zero temperature density varies with chemical potential as \(\partial n/\partial\mu=D(E_F)/V\). Since \(dp=n\,d\mu\) at fixed temperature, the electronic inverse compressibility \(1/\kappa_T=n^2/(\partial n/\partial\mu)=2nE_F/3\). In the example this corresponds to about 64 GPa. A compressibility measurement of the full solid includes lattice elasticity and charge-neutrality effects, so it cannot generally be substituted directly for an isolated electron-fluid result.
A confined electronic layer contacted through a gate can instead provide a thermodynamic density response through its quantum capacitance. If an induced charge increment per area is \(e\,dn\), part of the applied electrochemical voltage changes chemical potential by \(d\mu/e\). The corresponding capacitance per area is \(C_Q/A=e^2(\partial n_{2D}/\partial\mu)\). In a simple series combination the geometric dielectric capacitance and quantum capacitance both reduce the measured gate capacitance. Comparing a measured total directly to \(e^2D\) without removing the geometrical part can create an artificial density-of-states suppression.
Three independent measurements of low-temperature \(C/T\), Pauli spin response and a properly interpreted compressibility all probe the density of states in this noninteracting model. Their ratio then removes \(D(E_F)\) from some combinations. Correlations can renormalise spin response differently from specific heat. Orbital diamagnetism, closed-shell ions and temperature-dependent impurity moments must also be separated from a measured total susceptibility. A disagreement is an opportunity to distinguish these separate ingredients, not immediate evidence that state counting itself has failed.
A nonlinear zero-temperature spin response beyond Pauli's slope
At low magnetic fields the shift of either spin population is linear and nearly invisible in total number. To see where the susceptibility approximation comes from, retain the exact zero-temperature band populations. For a parabolic three-dimensional band with field-independent mass, absorb the two equal spin degeneracies into a coefficient \(A\) such that \(n_\pm=A[\mu\pm\mu_BB]_+^{3/2}\). The positive part enforces an empty spin band if its shifted edge lies above the chemical potential. The total \(n_++n_-\) must remain fixed in an isolated neutral sample, while \(M=\mu_B(n_+-n_-)\).
Expand both powers at small field. Linear terms cancel in the total density, so the chemical potential changes only at quadratic order. At fixed original Fermi energy the solution is
Population imbalance retains the linear term \(3\mu_BB/(2E_F)\) as a fraction of total density. This derivation checks why simply leaving \(\mu\) fixed gives the correct weak-field magnetisation slope yet fails in higher-order density calculations.
Complete spin polarisation in this model occurs when \(\mu-\mu_BB\) reaches zero. All particles then occupy the lower spin band, with effective Fermi energy relative to that band's shifted bottom equal to \(2^{2/3}E_F\). It follows that \(\mu_BB_{\rm pol}=2^{-1/3}E_F\). For a 7.05 eV metal this corresponds to roughly \(9.7\times10^4\) tesla, far outside the regime of an ordinary static bench measurement and outside a naive description of unmodified material bands. The number is a scale comparison, not a proposed magnet design. A system with a much lower Fermi energy or an enhanced effective magnetic moment can show nonlinearity at far lower applied fields.
A practical diagnostic compares positive and negative fields after subtracting the holder signal. Pure weak Pauli response is odd and linear in field with little temperature dependence. Localised impurity spins may also be odd but exhibit curvature or saturation when their Zeeman energy competes with temperature. A carrier density changing with field can alter the inferred Pauli slope. Therefore pair a magnetic measurement with a density or transport measurement before attributing every nonlinearity to spin-band depletion.
Extract a two-dimensional density of states from a gate measurement
Take a uniform conducting layer gated by a planar metal through an insulating spacer. An increment in gate voltage partly changes electrostatic voltage across the insulator and partly shifts the electronic chemical potential. In a simple uniform single-sheet model the charge-density increment \(dq=e\,dn_{2D}\) obeys \(dV_g=dq/c_g+d\mu/e\), where lowercase \(c_g\) is geometric capacitance per area. Writing \(c_q=e^2\,dn_{2D}/d\mu\) gives
This derivation assumes a stable uniform equilibrium state and a calibrated voltage reference with negligible leakage.
Suppose independent dielectric calibration gives \(c_g=5.00\,\mu{\rm F\,cm^{-2}}\), while a low-frequency gate measurement yields
The inferred quantum capacitance is \(c_q=7.50\,\mu{\rm F\,cm^{-2}}=0.0750\) F per square metre. Dividing by elementary charge squared gives \(2.92\times10^{36}\) states per joule per square metre, or \(4.68\times10^{17}\) states per eV per square metre. Confusing total sample capacitance with capacitance per area would produce a quantity that cannot be compared across different device sizes.
Sensitivity of the inverse step depends strongly on the ratio of the two measured values. If \(c_q\gg c_g\), the measured value approaches the geometric one. Small calibration offsets then dominate their reciprocal difference. For example, a measured value only one percent below \(c_g\) implies \(c_q\simeq99c_g\); an absolute error of one percentage point can remove any useful upper bound. In that limit the data support a lower bound on density of states rather than a precise central value.
Vary gate frequency to test whether traps or charge-relaxation delays contribute. A legitimate equilibrium compressibility response should be approached in the low-frequency limit under conditions where the electronic layer remains coupled to its reservoir. Interface states with slower charging can add a dispersive contribution that looks like extra density of states at one chosen frequency. Compare in-phase capacitance and loss, control for parasitic capacitance and measure several layer areas. Area-proportional capacitance and perimeter-dependent fringe capacitance can often be separated with devices of differing aspect ratio.
A differential heat pulse resolves the small electronic component
At low temperature a metal frequently has \(C_{\rm sample}=\gamma T+\beta_D T^3\) over a limited range. A platform and thermometer add their own heat capacities. A measurement might apply a known energy pulse and fit a temperature relaxation through a calibrated weak thermal link. To infer instantaneous heat capacity from \(Q/\Delta T\), the pulse must be small enough that \(C\) is nearly constant across the excursion and losses over the pulse negligible, or the energy balance must explicitly include them.
For a 10 mmol sample with \(\gamma=0.80\) mJ per mole per kelvin squared and \(\beta_D=0.10\) mJ per mole per kelvin to the fourth, molar heat capacity at 2 K is \(1.60+0.80=2.40\) mJ per mole kelvin. The sample heat capacity is 24.0 microjoules per kelvin. A 1.2 microjoule pulse would raise it by about 0.050 K neglecting heat leakage and addenda. The electronic fraction here is two thirds. At 4 K the lattice contribution exceeds the electronic term, changing which temperatures most strongly constrain the intercept in a \(C/T\) fit.
An exact small-range energy calibration uses the integral \(Q=\gamma(T_f^2-T_i^2)/2+\beta_D(T_f^4-T_i^4)/4\) times the sample amount. This avoids confusing a finite pulse average with the capacity at the initial temperature. Measure the empty platform through the same range and apply the same thermal model. A mismatch in thermal contact may create a second relaxation time and imitate sample heat capacity. Two pulses of different sizes and a delayed thermometer provide an independent test of the assumed lumped-temperature approximation.
The density of states inferred from \(\gamma\) measures excitations that can equilibrate during the experiment. A superconducting transition, magnetic ordering, a low-lying impurity contribution or a gap around the Fermi level would change the temperature dependence qualitatively. Rather than forcing a linear plus cubic fit over such structure, identify a normal-state range or include a separately justified physical term. A visually straight line on a narrow interval can hide curvature large enough to alter the intercept materially.
How a Fermi window rounds a sharp density-of-states edge
A two-dimensional band with a constant density of states starting abruptly at energy zero provides an exactly soluble compressibility edge. Differentiating its number equation gives \(dn/d\mu=D_0/[1+e^{-\beta\mu}]\) if \(D_0\) is per area. At zero temperature the response jumps from zero to \(D_0\) as the chemical potential crosses the band edge; at finite temperature it rises as a logistic function. The width between ten and ninety percent equals \(2k_BT\log9\), approximately \(4.39k_BT\).
At 10 K that intrinsic energy width is about 3.79 meV. At 30 K it becomes 11.36 meV. A gate experiment converts voltage to energy using a lever arm that may depend on the same quantum capacitance being measured. Calibrate that conversion before inferring temperature from edge width. Static disorder, inhomogeneous local band edges or electrical noise broaden the edge even at low temperature. Plot width against temperature and compare the full convolution model rather than interpreting a nonzero intercept as an electronic thermal floor without independent evidence.
This edge example shows exactly where a low-temperature expansion in smooth density derivatives fails. Every derivative of the constant band interior is zero, yet if the chemical potential lies within a few thermal energies of its abrupt edge there is a strong measurable density response crossover. Numerical integration of the full Fermi function or the exact analytic expression automatically retains this boundary. A calculation based solely on the local derivative of a density of states sampled within the band cannot recover it.
Separate Pauli spin response from independent local moments with a concentration test
A common experimental model of weakly magnetic metallic matter combines an approximately constant itinerant-electron susceptibility with a dilute Curie term \(C/T\) from paramagnetic impurities. At modest fields the local moment of independent spin-half sites with magnetic moment magnitude \(\mu\) has average \(m=\mu\tanh(\mu B/k_BT)\). Its small-field derivative gives volume susceptibility \(\mu_0 n_i\mu^2/(k_BT)\). The conduction-electron spin response instead scales with the density of states at the Fermi level. Two subsystems exposed to the same bath can therefore have markedly different temperature dependences.
Suppose two volume-susceptibility readings in SI units are \(2.20\times10^{-5}\) at 10 K and \(1.45\times10^{-5}\) at 40 K. A fit to \(\chi_0+C/T\) gives \(C=1.00\times10^{-4}\) K and \(\chi_0=1.20\times10^{-5}\). For independent moment magnitude \(\mu_B\), the implied impurity number density is \(Ck_B/(\mu_0\mu_B^2)\simeq1.28\times10^{25}\) per cubic metre. Relative to a carrier density of \(8.5\times10^{28}\) this is only about 150 parts per million. A small population can dominate the temperature-dependent change without representing most of the material.
Two points cannot verify the Curie form, so repeat across temperatures and fields. At sufficiently high \(B/T\) the independent moments approach saturation while the ideal degenerate electron subsystem remains approximately linear. At fixed \(B/T\), plotting the temperature-dependent residual should approximately collapse for independent moments. Interacting or clustered impurities can display a shifted Curie–Weiss temperature, blocking or history dependence, and a distribution of moments can broaden the saturation shape. A successful two-point subtraction alone does not establish a unique background.
A related check uses calorimetry. A split two-level impurity contributes a field-dependent Schottky anomaly when its gap is several thermal energies. Changing field shifts this anomaly, whereas the leading electronic linear coefficient of a simple normal metal varies much less at modest fields. The integrated entropy of an isolated two-state population tends toward \(n_i k_B\log2\) when both orientations become equally populated. A count inferred from susceptibility can therefore be tested by a separately integrated excess heat capacity, once lattice and electronic backgrounds are constrained.
Take care with units and signs when comparing papers or instruments. Some report molar susceptibility, others volume susceptibility, and cgs and SI magnetic conventions differ by factors involving \(4\pi\) and volume conversion. Divide a volume susceptibility by number density only after identifying whether the number refers to all host atoms, carriers or the inferred localised impurities. Agreement to a few significant figures after an unverified unit conversion has little diagnostic value.
A final test estimates when local spins should start to saturate at a given field. At 5 tesla and 2 K a magnetic moment equal to one Bohr magneton has \(\mu_BB/(k_BT)\simeq1.68\). The independent-spin alignment is \(\tanh(1.68)=0.933\), already close to saturation. In the same field the example metal's relative itinerant spin imbalance remains only around \(6\times10^{-5}\). A common high-field measurement can therefore discriminate two very different microscopic populations even if both looked nearly linear at much smaller fields. Remanent magnetisation on returning to zero would be inconsistent with both ideal noninteracting equilibrium models. It would motivate a check for ferromagnetic contamination, anisotropic barriers or hysteresis in the measurement apparatus before refining a fit to either simple susceptibility law.
Decide which electronic states contribute to heat capacity
Change temperature relative to Fermi energy and compare the low-temperature approximation with the statistical occupation.
Tutorial · Recover a density of states from a calorimeter
A sample exhibits a low-temperature molar heat capacity \(C/T=0.80\,{\rm mJ\,mol^{-1}K^{-2}}+bT^2\). Use the intercept to estimate the total density of electronic states per mole per electronvolt. Compare with the prediction for one conduction electron per atom and \(E_F=7.0\) eV.
Extract the electronic coefficient and convert energy units
In joules the total molar density is \(D=3(0.00080)/(\pi^2k_B^2)=1.28\times10^{42}\) states per joule per mole. Multiplying by the number of joules per electronvolt gives \(2.05\times10^{23}\) states per eV per mole. For one electron per atom the ideal value is \(3N_A/(2E_F)=1.29\times10^{23}\) states per eV per mole. The fitted effective density is therefore about 1.59 times larger. A molar heat capacity must be paired with a molar density of states; using a sample volume here without a molar volume would create a dimensional mismatch.
To decide whether the enhancement reflects a nonfree band, interactions or a wrong temperature window, examine the linearity of \(C/T\) versus \(T^2\) over several restricted fit ranges. A low-lying impurity or additional vibrational mode can produce curvature that changes the intercept. Compare with independent band information and spin response after relevant backgrounds are subtracted.
Tutorial · Determine a weak-field magnetisation and its background
At 1.0 T the measured volume magnetisation is 7.0 A/m, independent of temperature over a low-temperature range. The sample's predicted Pauli susceptibility is \(1.22\times10^{-5}\). Estimate the residual susceptibility if the magnetisation is linear and explain why its sign alone does not identify an orbital model.
Compare quantities in the same magnetic convention
One tesla corresponds to \(H\simeq7.96\times10^5\) A/m in this weakly magnetic setting. The predicted Pauli magnetisation is 9.71 A/m. The residual is minus 2.71 A/m or \(\chi_{\rm residual}\simeq-3.4\times10^{-6}\). Orbital diamagnetism of an ideal bulk free-electron gas supplies a negative contribution, but core diamagnetism, band orbital effects and sample-holder background can also contribute. Measure an empty holder and both field signs, consider specimen shape and calibrate the sample volume. A nearly temperature-independent negative residual does not uniquely identify any one mechanism.
Tutorial · Why a constant two-dimensional density of states behaves differently
For an ideal two-dimensional parabolic band of constant total density \(D_0\) above energy zero, derive the finite-temperature chemical potential at fixed \(N=D_0E_F\). Compare its leading low-temperature change with the power-law shift in three dimensions.
Evaluate the number integral before expanding
The integral gives
Solving yields
Its deviation from \(E_F\) at low temperature is exponentially small, consistent with \(D'(E_F)=0\). A program that always imposes the three-dimensional negative quadratic shift would violate particle conservation in this band. The low-temperature heat capacity remains linear because \(D_0\) itself is nonzero.
At high temperature the same exact expression approaches the classical logarithmic chemical potential. Evaluate the low-temperature numerical form as \(E_F+k_BT\log(1-e^{-E_F/k_BT})\) to avoid overflowing the large exponential. Here numerical stability and correct dimensional density of states are independent requirements; solving one does not fix the other.
Cambridge Statistical Physics · Fermi gases, the Fermi surface and low-temperature response
Finite-size criticality and the evidence for a phase transition
Statistical mechanics from microscopic counting to material response
A finite magnet in zero field can reverse between two equally magnetised directions. Its exact mean magnetisation is then zero even below the temperature where a bulk material orders. Learn how to extract order, correlation length and critical exponents from finite measurements, and which apparent crossings or peaks would survive the thermodynamic limit.
What a finite magnet can and cannot spontaneously break
Consider a ferromagnetic Ising model with spins \(s_i=\pm1\), \(N=L^d\) sites, short-range coupling \(J>0\), and uniform field \(h\) in energy units. Its Hamiltonian is \(-J\sum_{\langle ij\rangle}s_is_j-h\sum_i s_i\). A finite partition sum contains finitely many positive analytic terms at positive temperature. For finite \(N\) it cannot develop a true nonanalyticity on the real positive-temperature axis. Yet derivatives can become large and measured distributions strongly bimodal as size grows.
Define total magnetisation \(M=\sum_i s_i\) and intensive order \(m=M/N\). At zero field, spin inversion pairs configurations of \(M\) and \(-M\), making the exact finite equilibrium mean zero. To define spontaneous order in the positive direction, take the thermodynamic limit at positive \(h\), then let \(h\to0^+\). Reversing that order gives zero. A finite record that stays on one side because reversals are rare has not performed the full finite-system equilibrium average. It can approximate a symmetry-selected state only with that interpretation stated.
The absolute magnetisation or its root-mean-square value remains positive in finite zero-field calculations. Even independent disordered spins produce \(\langle|m|\rangle\) of order \(N^{-1/2}\). Therefore a nonzero magnitude in one simulation cannot establish bulk order. Repeat over sizes and inspect its scaling. A weak applied field, surfaces or slow field drift can also select one sign in a laboratory, modifying the finite-size comparison.
Derive a response from connected fluctuations
Differentiate the finite partition function at fixed temperature. The susceptibility per site to energy field \(h\) is
where the last equality assumes a translationally invariant system and \(G_c(\mathbf r)=\langle s_0s_{\mathbf r}\rangle-\langle s_0\rangle\langle s_{\mathbf r}\rangle\). Long correlations amplify the response because many sites contribute together when one responds to a field. For an experiment using magnetic induction instead of the energy field, include magnetic moments and unit-system factors.
In a symmetric finite zero-field sample below the ordering temperature, transitions between the two bulk-like peaks can give a large contribution proportional to \(N\) to the full fluctuation susceptibility. To estimate within-phase fluctuations one sometimes forms \(\beta N(\langle m^2\rangle-\langle|m|\rangle^2)\). This is a different observable and not exactly the derivative of the finite symmetric mean with respect to \(h\). Report which definition is plotted. Mixing those definitions in a size collapse can change both amplitudes and the apparent location of extrema.
A correlation length may be estimated from the large-distance connected correlation decay away from criticality, or from the ratio of small-wavevector structure factors. In lattice units, an often used periodic second-moment length is
This relation uses the small-\(k\) expansion of the correlation structure factor and a lattice wavevector convention. Subtract means consistently, especially if estimating connected rather than symmetric correlations. If a small noisy \(S(0)/S(k_{\min})-1\) is negative, replacing it by zero without describing the noise can bias a length. Larger samples or more suitable observables may be preferable.
Derive the finite-size variable from competing lengths
Write reduced temperature \(t=(T-T_c)/T_c\). Suppose the bulk correlation length diverges as \(\xi_\infty=\xi_0|t|^{-\nu}\). A finite periodic sample cannot support correlations extending arbitrarily beyond \(L\). The competition is governed by \(L/\xi_\infty\), equivalently \(tL^{1/\nu}\) with its sign and a metric factor. If the bulk magnetisation, susceptibility and heat capacity have exponents \(\beta_m,\gamma,\alpha\), a standard finite-size ansatz below the appropriate upper critical dimension and without extra dangerous variables is
Here \(\beta_m\) is an order-parameter exponent, distinct from reciprocal thermal energy \(\beta\). The functional forms match the bulk powers when the scaled argument becomes large at fixed nonzero \(t\). A rounded finite-size peak of \(\chi\) occurs at an approximately fixed scaled argument, so its temperature shift and width scale roughly as \(L^{-1/\nu}\), allowing boundary and subleading corrections. Its height has an additional smooth background that can be significant for modest sizes.
For a two-dimensional short-range Ising universality class the known values \(\nu=1\), \(\gamma=7/4\), \(\beta_m=1/8\) give useful benchmarks. Doubling \(L\) at criticality should raise leading susceptibility by \(2^{7/4}=3.364\) and reduce order magnitude by only \(2^{-1/8}=0.917\). The very slow decrease of order is easy to mistake for nonzero bulk order at the critical temperature. The heat-capacity singularity in this example is logarithmic rather than a simple positive power; fitting a few peak heights to a power law can give a misleading small apparent exponent.
Compare a mean-field onset and susceptibility with the finite-size scaling argument
A dimensionless crossing and its systematic drift
A convenient shape diagnostic is \(U_L=1-\langle m^4\rangle/[3\langle m^2\rangle^2]\). A zero-mean Gaussian distribution has fourth moment three times variance squared and gives zero. Two infinitely narrow equal-weight peaks at \(\pm m_0\) give \(2/3\). At criticality, rescaling \(m\) by \(L^{-\beta_m/\nu}\) cancels between numerator and denominator, so curves for different sizes can approach an approximately common crossing. The limiting value depends on geometry, boundary conditions and convention, despite the exponent universality.
Include a leading correction \(U_L=U_*+a\,tL^{1/\nu}+bL^{-\omega}+\cdots\). Equating the expansions for \(L\) and \(sL\) shows that the pair crossing drifts as \(t_\times\propto L^{-(1/\nu+\omega)}\) when the coefficients are nonzero. An exactly common crossing is therefore not guaranteed in finite data. Sample temperature resolution, uncertainty of higher moments and correlations between neighbouring reweighted temperatures can also shift the visual crossing.
For a data set with sizes 16, 32 and 64, suppose adjacent pair crossings occur at reduced-temperature-like coordinates 2.31 and 2.28 when plotted as \(k_BT/J\). Without a calibrated correction exponent, taking their simple mean gives no justified bulk critical temperature. If a model independently predicts a crossing displacement decreasing by four per doubling, solve \(T_{16,32}=T_c+A\), \(T_{32,64}=T_c+A/4\), giving \(T_c=2.27 J/k_B\). Vary the correction assumption and use an additional larger size to test it. Extrapolated digits considerably beyond the scatter of these alternatives are not warranted.
Separate thermodynamic rounding from sampling error
Near criticality long spatial correlations often coincide with long relaxation times. A sequential Monte Carlo update can require many sweeps to produce independent configurations. If an observable has normalised autocorrelation \(\rho(k)\), its effective independent sample count for a long record is approximately \(N_{\rm samp}/[1+2\sum_{k>0}\rho(k)]\). Blocking time records and recomputing Binder ratios from blocks is more reliable than treating individual sweeps as independent.
If a susceptibility peak is represented by ten nearby temperatures generated from the same energy histogram, their errors are correlated. Temperature reweighting uses factors \(e^{-(\beta'-\beta)E}\) and is dependable only where sampled energy distributions overlap. A smooth reweighted curve extending outside sampled energies can look precise while depending on a few rare configurations. Use independent anchor simulations or directly measured temperatures to verify both tails.
Inspect distributions as well as means. A first-order transition can also show a large susceptibility peak and bimodality, with leading peak scaling proportional to volume in many finite systems. A continuous transition's order distribution may itself be broad or even possess two lobes. Distinguish using latent heat or its size dependence, interface free-energy barriers, scaling of peak width and appropriate thermal observables. One finite-size double peak in magnetisation is not a universal transition-order test.
An exact finite chain tests what a rapidly growing length means
A one-dimensional nearest-neighbour Ising chain in zero field has no positive-temperature bulk ordering transition, but at low temperature its correlation length grows extremely rapidly. This makes it a valuable counterexample when interpreting a finite magnet. The transfer matrix has entries \(e^{Kss'}\) with \(K=J/(k_BT)\). Its two eigenvalues are
For a periodic chain of \(L\) spins,
Keeping only the larger eigenvalue is permissible in the thermodynamic free-energy density at fixed positive temperature but need not accurately represent a short cold chain.
In the infinite chain the zero-field correlation is \(\langle s_0s_r\rangle=(\tanh K)^r\), yielding \(\xi=-1/\log(\tanh K)\) in lattice spacings. At low temperature \(\xi\simeq e^{2K}/2\). A chain of length 100 can therefore be strongly correlated across its entire length around \(K\simeq2.65\), while the infinite chain still has zero spontaneous order at every finite \(K\). Setting \(\xi\sim L\) gives an apparent ordering scale \(k_BT_L/J\simeq2/\log(2L)\), which moves slowly toward zero as the sample is enlarged.
For a periodic finite chain there are two paths connecting site zero and site \(r\). The exact correlation is \([q^r+q^{L-r}]/[1+q^L]\), \(q=\tanh K\). Fitting it to a single exponential out to separations near half the box would overestimate the length because the second periodic image contributes. Use the periodic expression explicitly or restrict fits to a window that is both larger than microscopic distances and smaller than half the sample. A high-quality apparent fit over a narrow middle interval can still mask the wrong boundary geometry.
Numerically simulate chains of lengths 32, 64 and 128 at a sequence of \(K\). Compare the measured absolute magnetisation, full connected correlation and transfer-matrix predictions. If a simulation remains stuck in one sign sector its short-distance correlation can agree with theory while the time average of signed magnetisation does not. Increasing the number of Monte Carlo sweeps and increasing the physical chain length are separate limits. Following only one of them cannot establish a nonzero thermodynamic order parameter.
A response derivative offers an exponent without partition-function normalisation
Let \(U_L\) be a dimensionless shape ratio such as the Binder cumulant. If \(U_L=\mathcal U(tL^{1/\nu})+\cdots\), its slope with respect to reduced temperature at the critical point scales as \(L^{1/\nu}\). A logarithmic slope ratio between two sizes can estimate the correlation-length exponent independently of the magnetisation or susceptibility exponents. Corrections to scaling still matter, especially if the sampled point is not near a fixed critical argument for both sizes.
An equilibrium derivative can also be computed without a finite temperature difference. For any state observable \(A\) with no explicit temperature dependence, differentiating its canonical mean gives
Apply this to the second and fourth moments entering a Binder ratio, then use the chain rule. The resulting slope uses energy–magnetisation correlations from one run. Taking two numerically close independent temperatures instead can amplify noise by division by their small separation. A covariance estimator avoids that particular subtraction but requires accurate sampling of joint tails.
Suppose measured absolute crossing slopes on sizes 24, 48 and 96 are 5.7, 10.9 and 21.5 per unit reduced temperature. Adjacent estimates are \(1/\nu=\log(10.9/5.7)/\log2=0.935\) and \(0.980\). They approach the expected value one in this benchmark. A single fit through all sizes would give a smaller formal statistical uncertainty but might obscure a systematic drift. Report adjacent effective exponents and test sensitivity to omitting the smallest size.
The numerical derivative must use the same temperature variable for each size. A slope against inverse temperature differs by \(d\beta/dT\), a known factor near a common critical temperature; plotting against independently fitted centre temperatures can introduce an additional calibration dependence. A nonlinear temperature sensor or a slowly drifting coupling also changes the physical conversion from laboratory temperature to the simulated dimensionless control. Use an independently determined parameter scale if the goal is to compare experiment with an absolute transition temperature rather than just a scaling exponent.
Estimate an interface cost from a probability trough
At a first-order transition, a finite periodic sample may switch between two phases separated by an interfacial configuration. A histogram of an appropriate extensive observable can show peaks corresponding to nearly pure phases and a trough representing intermediate states. At equal bulk phase weight, a probability ratio gives a free-energy difference \(\Delta F_L=-k_BT\log(P_{\rm trough}/P_{\rm peak})\), provided the same bin measure or a properly defined density is used. An exponentially small trough amplifies sampling errors, so the measured minimum is often only an upper bound on its probability.
In a slab geometry under periodic boundaries, an intermediate configuration may contain two approximately flat interfaces. If each interface costs \(\gamma L^{d-1}\), the leading barrier is \(2\gamma L^{d-1}\), with subleading capillary fluctuations, geometry corrections and possible droplet-to-slab crossovers. A cube with open boundaries can instead permit interfaces of different number or shape. Counting two interfaces automatically for every order-parameter histogram would misestimate the inferred tension.
For an illustrative two-dimensional periodic square, suppose the measured barrier grows from \(8k_BT\) at \(L=40a\) to \(15k_BT\) at \(L=80a\), where \(a\) is lattice spacing. From the difference of the two barriers and the increase in total interface length \(2(40a)\), an effective line tension is \(0.0875\,k_BT/a\). Using the absolute smaller-size barrier divided by \(2L\) gives \(0.100\,k_BT/a\), revealing a finite-size offset. More sizes, an observed slab geometry and adequate trough sampling are needed before assigning a bulk interface tension.
This analysis should not be transplanted unchanged to a continuous critical distribution with two shoulders in finite volume. A critical finite-size order distribution can be non-Gaussian without an interfacial barrier growing as \(L^{d-1}\) at its critical point. Plot the barrier's size dependence and inspect actual spatial configurations. A peak-height ratio alone contains no direct information about how many interfaces or what type of correlations generated the intermediate states.
Estimate a ratio of moments without losing its covariance
The second and fourth magnetisation moments in a Binder cumulant usually come from the same record. Treating their errors as independent can grossly misestimate the uncertainty because the fourth moment tends to be large precisely in configurations contributing a large squared moment. Divide the record into blocks longer than its integrated autocorrelation time, recompute the ratio after deleting each block and estimate uncertainty using a block jackknife or use independent replicate simulations. Recomputing the nonlinear statistic inside each resample retains numerator–denominator covariance.
Histogram reweighting across nearby temperatures should likewise be recomputed within each block when extracting a crossing. Fitting smooth curves to the full sample and then adding independent random errors to individual temperature points ignores strong correlations induced by the shared configuration weights. Repeat the root-finding step for each independent or block-resampled pair of systems to obtain an uncertainty on the crossing temperature itself.
Check block-size convergence. If estimated errors continue growing as block duration is increased, slow modes may not be resolved or the record may have drifted. A huge number of recorded spin configurations cannot compensate for fewer than a handful of independent reversals when the statistic depends on those reversals. This issue is measurable: compare direct covariance estimates, block estimates and independent starts, and extend the run where those diagnostics disagree.
A block-average variance exposes a correlation length without fitting a tail
Divide a large zero-field spin image into square blocks of side \(b\) and record the average spin in each block. Its variance is the sum of all connected correlations within the block divided by the squared number of sites. For independent spins of variance one, it is exactly \(1/b^2\) in two dimensions. If neighbouring spins are correlated over a length \(\xi\) much smaller than the block, the variance still falls approximately with inverse block area, but with a larger prefactor proportional to the integrated correlation. Below block sizes comparable to \(\xi\), this averaging becomes much less effective.
At a critical point the connected correlation decays algebraically rather than exponentially over the accessible range. If in dimension \(d\) it behaves as \(G(r)\propto r^{-(d-2+\eta)}\), integrating pair separations to the block scale gives \({\rm var}(m_b)\propto b^{-(d-2+\eta)}\) in the scaling regime. For the two-dimensional short-range Ising benchmark with \(\eta=1/4\), doubling the block side reduces the variance by only \(2^{-1/4}=0.841\), compared with 0.25 for independent spins. This is an observable distinction even when a full bulk thermodynamic limit is unavailable.
Block analysis of one image does not generate independent thermodynamic systems. Neighbouring blocks share correlated surroundings, overlapping blocks are statistically dependent, and every block inherits global constraints or drift in the original preparation. Increasing block size also reduces the available count sharply. Repeat across independent configurations, compare several whole-image sizes and study block-size windows well above a lattice spacing and well below the full image. An apparently accurate critical exponent from the final two largest blocks of one image is particularly unreliable.
A real magnetic image may measure a blurred field projection rather than the local spin itself. Spatial point spread creates detector-induced correlations at small separations. Determine it with a reference pattern and omit or model blocks comparable to the blur. Conversely spatially varying illumination adds long-range covariance unrelated to the sample. Flat-field calibration and sample rotations can separate these artefacts from material correlations. A second-moment structure-factor estimate and a block-variance estimate respond differently to these measurement effects, providing a useful cross-check.
This method also links microscopic and macroscopic noise. The scaled block variance in the large-block regime approaches the same integrated connected correlation controlling uniform susceptibility, with boundary terms that shrink as block dimensions exceed \(\xi\). Comparing a weak-field response with block statistics therefore tests equilibrium fluctuation–response and spatial calibration simultaneously. If the discrepancy grows only as blocks approach the full system size, a fixed total magnetisation constraint or incomplete sampling of global sign reversals deserves examination.
For a concrete noise budget, consider a camera averaging adjacent pairs of independent sites before reporting them as displayed pixels. Those displayed pixels can have a positive nearest-neighbour correlation if their averaging footprints overlap, even when the original spins are completely uncorrelated. A measurement of the apparent short-range correlation length would then reflect the instrument kernel. Blocking on sizes much larger than the overlap can recover the correct large-scale inverse-area trend, while direct comparison of single-pixel variance with independent-spin theory fails. Calibrating only the detector's global gain cannot fix this spatial response. A measured point-spread map, an uncorrelated reference preparation and tests of blocks at several image resolutions can separate the resolution scale from the material's growing correlation length as temperature is varied.
Compare a correlation length with a finite specimen
Determine how the subleading transfer-matrix eigenvalue controls the length seen in a colour measurement. A finite chain much shorter than this length can look ordered.
Tutorial · Extract two exponent ratios from a size doubling
At a candidate critical temperature susceptibilities for sizes 32 and 64 are 110 and 360 in common units. Absolute magnetisations are 0.310 and 0.282. Estimate the corresponding exponent ratios and compare with the two-dimensional Ising benchmarks.
Use logarithmic ratios and inspect the small differences
The susceptibility ratio gives
For magnetisation \(\beta_m/\nu=-\log(0.282/0.310)/\log2=0.137\). These are near 1.75 and 0.125, but no error bars or corrections have been supplied. An additive susceptibility background or a slight critical-temperature offset can bias both effective exponents. Use several sizes and a dimensionless crossing diagnostic before assigning a universality class.
Tutorial · Determine whether a finite sample really switched phases
A zero-field record contains 20,000 sweeps of positive magnetisation near \(+0.6\), followed by one reversal and 20,000 sweeps near \(-0.6\). It yields a near-zero mean and large variance. Why does the nominal record length not establish a precise symmetric susceptibility? What extra records or controls would help?
Identify the slow event determining the uncertainty
Within each sign sector there may be many locally decorrelated fluctuations, yet the relative weight of the two peaks is estimated from essentially one reversal. Treating 40,000 sweeps as independent underestimates the error of the peak weights and of statistics sensitive to global sign. Starting multiple independent runs with both signs can improve coverage, but deliberately balancing starting signs is not a measurement of true equilibrium weights if a weak residual field exists.
Record switching-time distributions over much longer runs or use an equilibrium-preserving algorithm that efficiently samples both sectors, while distinguishing computational updates from physical kinetics. Apply small positive and negative fields to test susceptibility and residual bias. For a within-phase susceptibility condition on a clearly defined phase and report the changed observable.
Tutorial · Explain a crossing that drifts with the boundary
Two groups study the same lattice Hamiltonian. One uses square periodic samples; the other uses twice-as-long rectangular samples with open ends. Their Binder curves cross near similar temperatures but at different cumulant values. Is this evidence against universal critical behaviour?
Separate universal exponents from finite-geometry functions
Changing aspect ratio and boundary conditions changes the finite-size scaling function and hence the crossing value of a dimensionless ratio. Universal bulk exponent comparisons do not require identical Binder values across different finite geometries. Match boundary conditions, shape, operator and cumulant convention before comparing purported universal amplitude ratios.
Each group can still extrapolate its own crossing temperatures, examine moment slopes proportional to \(L^{1/\nu}\) and test bulk exponent ratios with geometry fixed across its own size series. If one dimension is held fixed while the other grows, however, the family approaches a strip rather than a bulk two-dimensional limit. The thermodynamic sequence itself is an experimental variable, not just a plotting preference.
Cambridge Statistical Physics · phase transitions, criticality and scaling
How many lattice sites remember the colour of a neighbour?
Counting, correlations and thermal measurements
A chain of three-state spins gains energy when adjacent colours agree. A weak field favours one colour over the other two. Use a transfer matrix to calculate both free energy and the distance over which correlations survive. Recover the same numbers from OneSimulation eigenvalues without relying on symmetry reduction.
Find a local weight whose product counts each energy once
Each site has colour \(a=0,1,2\). A matching pair contributes energy \(-J\), with \(J>0\), and a site of colour zero earns an additional \(-H\). In a periodic ring each site belongs to two adjacent bonds. Give each of those bonds half the local field energy so the product of their weights counts each field term exactly once. Define \(K=J/(k_BT)\) and \(h=H/J\).
To see the trace, write the partition function as a sum over \(a_1,\dots,a_N\) of the product \(M_{a_1a_2}\cdots M_{a_Na_1}\). Summing an intermediate index is matrix multiplication; closing the initial and final index is the trace. This is exact even for a short periodic chain defined by that bond count. The transfer matrix contains no time step: multiplying it advances spatial position.
Compare the leading eigenvalue with the next one
Without bias the matrix has diagonal \(e^K\) and all other entries one. The uniform vector has eigenvalue \(e^K+2\). Every vector with components summing to zero has eigenvalue \(e^K-1\), twice degenerate. Thus \(Z_N=(e^K+2)^N+2(e^K-1)^N\). The thermodynamic free energy per site is \(-k_BT\ln(e^K+2)\). To measure a connected spatial correlation, insert a diagonal colour observable at sites separated by \(r\) transfer operations. The uniform contribution cancels from the connected part; each nonuniform mode contributes a factor \((\lambda_j/\lambda_1)^r\) when its overlap is nonzero. The longest correlation length in sites is
At \(k_BT=J\) and zero bias, \(\lambda_1=4.71828,\ \lambda_2=1.71828\) and \(\xi=0.9900\) sites. At low temperature \(e^K\) is large and \(\xi\simeq e^K/3\). A finite chain can then appear ordered simply because it is shorter than its correlation length. There is no finite positive temperature at which these two one-dimensional eigenvalues cross.
Keep track of a mode that a chosen detector cannot see
At \(h\ne0\), colours one and two remain interchangeable. Their difference vector is an eigenmode of eigenvalue \(e^K-1\). In the orthonormal basis comprising colour zero and the sum of one and two, the remaining block is
Its eigenvalues follow from the trace and the square root of the squared diagonal difference plus four times the squared off-diagonal element. Sort all three eigenvalues. A detector sensitive only to whether the spin is zero is invariant under interchange of colours one and two. It has no overlap with their odd difference mode, even if that mode sets the mathematically longest length. A resolved measurement of colours one and two can see it. Quoting a correlation length from eigenvalues requires specifying which observation can actually couple to that eigenvector.
Change temperature and examine the spectral gap
Vary reduced temperature and reduced field \(H/J\) independently. The plot compares the longest colour-correlation length to the exact zero-field result. At a chosen point the downloadable model constructs the full three-by-three matrix and computes its modes using OneSimulation's contour eigensolver. It reports free energy per site and all three eigenvalues. In this small system the direct reduction above is available as an independent check. The same matrix construction generalises to more states even when no colour symmetry reduces the size.
Compare two chains at the same temperature. Set the colour bias to zero and apply a positive bias of 0.30 J. Use the transfer-matrix eigenvalue ratio to explain the change in the longest correlation length.
Tutorial
At \(k_BT=J,\ h=0\) what fraction of the asymptotic leading contribution to a connected correlation survives after three lattice sites?
Work through the solution
The factor is \((1.71828/4.71828)^3\simeq0.0483\). The correlation observable sets its initial amplitude; the eigenvalue ratio sets this fraction.
Why does squaring a single bond weight to represent the effect of two bonds give the wrong two-step transition amplitude?
Work through the solution
Two steps can pass through any of the three intermediate colours. Matrix multiplication sums all possibilities \(M_{ab}M_{bc}\) over \(b\). Squaring the single number \(M_{ac}\) loses those intermediate configurations.
Suppose only the leading eigenvalue is reliably resolved. Which thermodynamic-limit prediction is possible and which remains undetermined?
Work through the solution
One can obtain free energy per site, and with its parameter dependence the derivatives giving energy or magnetisation. A connected spatial length requires a subleading eigenvalue and overlap of the chosen observable. A precise leading free energy alone cannot give that numerical length.
Compare this transfer calculation with the two-state Ising chain experiment.
Periodic potentials, interfaces and experimental probes
Follow a state across a boundary, a band gap or an avoided crossing. Use optical, tunnelling and calorimetric probes to distinguish an energy gap from a loss peak.
- Scattering and tunnelling in one dimension
- Transitions under a timed drive
- Boundary conditions that carry a current around a ring
- Adiabatic following and a finite sweep through an avoided crossing
- When a periodic dielectric has no propagating Bloch wave
- Measuring magnetic core loss by a hysteresis loop and by calorimetry
- From a Coulomb orbit to the fine-structure multiplet
- Two electrons, exchange splitting and the cost of localisation
- Measure tunnelling from a four-site spectrum
Scattering and tunnelling in one dimension
Match stationary waves across a potential discontinuity and use probability current to distinguish reflection, propagation and an evanescent field.
From first principles
Obtain reflected and transmitted probabilities at a potential step
Suppose a constant-mass particle reaches a flat potential step from the left with energy above both sides. In a region of constant potential the stationary Schrödinger equation has waves \(e^{\pm ikx}\) with \(\hbar^2k^2/2m=E-V\). Set the incoming amplitude to one and use asymptotic waves \(e^{ik_1x}+r e^{-ik_1x}\) at left and \(t e^{ik_2x}\) at right. Integration of the differential equation across the finite step makes the derivative continuous; the wave function itself is continuous as well:
Solving the two linear conditions gives
The current from the previous chapter for one travelling component is \(\hbar k|A|^2/m\) in its propagation direction. Ratios to incoming current therefore yield
Equal potentials give unity transmission. Near a right-hand threshold \(k_2\to0\), a finite boundary amplitude can coexist with vanishing transmitted flux because the outgoing velocity also tends to zero.
Background · Probability current
This expression assumes a scalar particle with no vector potential. Transmission probabilities require outgoing relative to incoming current, even when their wave numbers differ.
Open full-size diagram
Try it · Physics lab double well splitting
Explore the same physical relation with adjustable inputs. This independent parameter study has its own displayed reference settings; compare its assumptions and units before matching the static example.
Derivation and applications
Match both faces of a finite barrier
A decaying wave inside a classically inaccessible interval does not alone determine its transmission. Boundary matching at the exit also contributes. Let \(V(x)=V_0\) for \(0<x<L\) and zero outside, with a particle of constant mass and \(0<E<V_0\) incident from the left. Define \(k=\sqrt{2mE}/\hbar\) and \(\kappa=\sqrt{2m(V_0-E)}/\hbar\). Set the phase reference at the exit so the outgoing wave is \(t e^{ik(x-L)}\). At \(x=L\), continuity gives both the exit value \(t\) and its derivative \(ikt\).
Inside, \(\psi''=\kappa^2\psi\). Propagate these exit data back to the entrance using the even and odd solutions:
On the left write \(e^{ikx}+r e^{-ikx}\). Adding its value to its derivative divided by \(ik\) removes the reflected amplitude. Inserting the propagated data yields
Both asymptotic waves propagate in the same material, so their velocity factors cancel in the current ratio. Take the squared magnitude and use \(\cosh^2u=1+\sinh^2u\):
A barrier of vanishing width transmits fully. An exponential estimate at large \(\kappa L\) neglects the interface-dependent prefactor. Close to the top, the \(\sinh\) factor and its apparently singular coefficient must instead be taken to the limit together.
Worked example
Infer a width from a tunnelling measurement
Change the inputs and investigate this derivation.
At \(E=V_0/2\), \(k=\kappa\) and the result simplifies to \(T=\operatorname{sech}^2(\kappa L)\). A device with \(\kappa=2.00\) nm⁻¹ has \(T=0.250\). Thus \(\cosh(\kappa L)=2\) and \(L=\operatorname{arcosh}(2)/2.00=0.658\) nm. Doubling that width gives \(\cosh(2\kappa L)=2(2)^2-1=7\), hence
Second application
Approach the top from below
Change the inputs and investigate this derivation.
Let \(E\to V_0\) at fixed \(L\). With \(\sinh(\kappa L)\simeq\kappa L\) the transmission becomes
For \(k=3.00\) nm⁻¹ and \(L=0.500\) nm this is \(0.640\). A vanishing inverse decay length therefore does not guarantee complete transmission. Exactly at the barrier top the internal solution becomes linear and still has to match the slopes on both sides.
Try it · Barrier transmission
Vary the physical parameters in the derived relation. Use the units and assumptions in the readout to connect the curves to the two worked examples. A parameter study can test the forward prediction; the same relation can then be inverted to infer a parameter from a measurement.
Build a scattering state
Send a narrow band of particles from the left towards a region where the potential changes. Far from the obstacle a stationary energy component has incoming and outgoing travelling waves. Such plane waves are not normalisable on the whole line, but their flux ratios describe what happens to a sufficiently long incident packet whose momentum distribution is narrowly centred. Assume a particle of constant mass and a real, finite, time-independent potential.
The stationary Schrödinger equation is
Integrating it over a shrinking interval around a finite step gives continuity of \(\phi'\); a finite jump in \(\phi\) itself would introduce a more singular derivative, so \(\phi\) is continuous as well. These matching laws change for an ideal delta potential, an infinite wall or an effective mass discontinuity. Stating the model at an interface matters as much as solving the constant-potential regions.
Partly reflect above a potential step
Take \(V=0\) for \(x<0\) and \(V=V_0\) on the right. For \(E>V_0\), write \(\phi_L=e^{ikx}+r e^{-ikx}\) and \(\phi_R=t e^{iqx}\), with \(k=\sqrt{2mE}/\hbar\) and \(q=\sqrt{2m(E-V_0)}/\hbar\). Matching gives \(1+r=t\) and \(k(1-r)=qt\). Thus \(r=(k-q)/(k+q)\) and \(t=2k/(k+q)\). A wave can reflect from a change of wavelength even if a classical particle has enough energy to proceed.
A right-moving component \(Ae^{ikx}\) carries current \(\hbar k|A|^2/m\). Consequently \(R=|r|^2\) while \(T=(q/k)|t|^2\), and direct substitution gives \(R+T=1\). For \(E=4V_0/3\), \(q=k/2\), so \(r=1/3\), \(t=4/3\), \(R=1/9\) and \(T=8/9\). Although the transmitted wavefunction amplitude is larger than the incident one, its reduced group velocity keeps the transmitted probability flux below the incident flux.

Try it · Step scattering
Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.
Background · Why can a transmitted amplitude exceed one?
For incidence from the left, match the wavefunction and its derivative at a potential step with equal particle masses and positive real wavenumbers \(k_L,k_R\). With unit incident amplitude the transmitted amplitude is \(t=2k_L/(k_L+k_R)\). A detector downstream counts probability crossing its position per unit time. The current in a right-travelling plane wave includes its group velocity.
For \(k_R=k_L/3\), the transmitted amplitude is 1.5, its intensity factor is 2.25, and its transmitted current fraction is 0.75. The reflected fraction supplies the other 0.25. The density increases because the transmitted particles propagate more slowly. Using flux-normalised channel states absorbs the velocity factor into the scattering amplitude.
Follow an evanescent field
If \(0<E<V_0\), the right-hand wave number becomes \(i\kappa\) with \(\kappa=\sqrt{2m(V_0-E)}/\hbar\). The physical solution for a semi-infinite step decays as \(e^{-\kappa x}\). This single exponential times a constant has zero current, since its spatial derivative has the same complex phase. It nevertheless has finite density a short distance into the forbidden region. Matching at the interface now gives a reflected wave of unit magnitude with an energy-dependent phase.
A finite barrier differs because an allowed region begins again at \(x=L\). Both decaying and growing exponentials must be retained within the barrier, and their relative complex coefficient allows nonzero current. Match the wavefunction and derivative at both ends. For equal zero potentials on the outside the transmission probability reduces to
The large-width dependence comes from \(\sinh(\kappa L)\sim e^{\kappa L}/2\). At fixed barrier height it is the exponential sensitivity to width that makes tunnelling useful as a distance probe. A single semi-infinite exponential fitted to density cannot by itself supply the finite-barrier prefactor.
Estimate the effect of a subnanometre change
For an electron with \(E=1.0\) eV and \(V_0=2.0\) eV, \(\kappa\simeq5.12\) nm⁻¹ and the prefactor of \(\sinh^2\) is exactly one. At width 0.50 nm,
At 1.00 nm, \(T\simeq1.43\times10^{-4}\). Doubling this subnanometre gap suppresses transmitted current by roughly a factor of 165 for equal incident current.
The calculation assumes a sharp rectangular barrier, one occupied incident energy and elastic coherent scattering. A measured electric tunnel current generally combines many available occupied and empty states across an energy window. A current ratio is therefore most directly compared with the single-energy exponential when barrier shape and occupation stay sufficiently similar across the distance change.
A more detailed test uses scattering from opposite sides of a real, static barrier at the same energy. Time-reversal symmetry implies equal transmission probabilities for a single channel, even when the spatial barrier profile is asymmetric. The two reflection phases can differ. If the exterior potentials differ, the transmitted amplitude ratios from the two sides need not coincide because their travelling states carry different current per unit amplitude. Normalizing the prepared and detected states to unit flux removes that ambiguity. Checking incident current against the sum of outgoing currents separately tests whether the model conserves probability.
Solve for scattering and binding at one narrow defect
A point interaction illustrates how the same Hamiltonian predicts both scattering and bound states. On an infinite line take \(V(x)=g\delta(x)\), with \(g\) having units of energy times length. This limiting model replaces a narrow feature when the wavelength of interest greatly exceeds its microscopic width. The wavefunction remains continuous, but integrating the stationary Schrödinger equation from \(-\eta\) to \(+\eta\) before taking \(\eta\to0\) gives the derivative jump
For a particle incident from the left, write \(\psi=e^{ikx}+re^{-ikx}\) on the left and \(te^{ikx}\) on the right. Continuity gives \(t=1+r\). Inserting both derivatives into the jump condition and defining \(\xi=mg/(\hbar^2 k)\) gives
The external speeds are equal on both sides, so \(T=1/(1+\xi^2)\) and \(R=\xi^2/(1+\xi^2)\). The sum is one for real \(g\). Transmission probability depends only on the magnitude of the interaction, but the complex phase of the transmitted wave distinguishes its sign.
For negative energies the exterior solution must decay as \(e^{-\kappa|x|}\). Its derivatives jump by \(-2\kappa\psi(0)\), giving \(\kappa=-mg/\hbar^2\). A normalizable state requires \(\kappa>0\), hence only an attractive defect binds. The bound energy is \(-\hbar^2\kappa^2/(2m)\). A one-dimensional narrow attractive defect can therefore support binding even when a scattering-probability measurement alone cannot distinguish its sign.
Compare two defects with the same transmission
Use electron mass and take \(|g|=0.0762\) eV nm. Since \(\hbar^2/(2m_e)=0.0381\) eV nm², \(m_e|g|/\hbar^2=1.00\) nm⁻¹. An incoming wave with \(k=2.00\) nm⁻¹ has energy \(0.152\) eV and \(|\xi|=0.500\). Both signs of \(g\) transmit 0.800 and reflect 0.200 of the incident probability current. The transmission phases, however, are \(\mp\arctan(0.500)=\mp26.6^\circ\), a difference observable against a reference path.
For the attractive sign the decay length of the bound state is \(1/\kappa=1.00\) nm and its energy is \(-0.0381\) eV. The repulsive sign has no such state. At high incident \(k\) both become nearly transparent; at small \(k\) both produce nearly complete reflection for fixed nonzero strength. The order of these limits matters: taking \(g\) to zero first gives perfect transmission at any finite incident wavenumber.
An attractive defect with the inferred decay constant has normalized bound state \(\psi=\sqrt{\kappa}\,e^{-\kappa|x|}\). The probability outside distance \(b\) from the defect is \(e^{-2\kappa b}\) after integrating both tails. With \(b=1.00\) nm in the example this gives 0.135, despite each wave amplitude at that distance being \(1/e\) of its central value. A numerical calculation in a box can use this estimate to choose outer boundaries. Placing artificial zero-value boundaries only one decay length away would remove substantial tail probability and shift the apparent bound energy upward.
Increasing the box symmetrically and tracking the bound energy is more informative than merely refining the spatial mesh in the original box. Mesh convergence at fixed outer boundaries can certify a well-resolved solution of the wrong finite-domain physical problem.
Transitions under a timed drive
Derive the line shape of a weak finite-duration drive and distinguish Fourier width from a system’s intrinsic lifetime.
From first principles
How the time profile of a drive becomes a transition amplitude
Assume an initially occupied eigenstate \(|i\rangle\) of a time-independent Hamiltonian \(H_0\), perturbed by a weak time-dependent operator \(V(t)\). Expand the state in its unperturbed energy eigenvectors and factor out their known phases. Inserting the expansion into the time-dependent Schrödinger equation cancels the unperturbed energy terms:
At first order the right side uses the initial amplitudes \(c_i=1,c_{n\ne i}=0\). Integrating from zero through pulse duration \(T\) gives
A square nearly resonant sinusoidal drive has a slowly varying integrand proportional to \(e^{i\Delta t}\) plus a rapidly oscillating component. Keeping the slow term produces amplitude proportional to \(T\,\mathrm{sinc}(\Delta T/2)\) and probability proportional to its square. The approximation requires small population transfer; a longer resonant drive eventually requires coupled state amplitudes.
Derivation and applications
Why a strong resonant pulse stops increasing the transition probability
Perturbation theory predicts a probability growing as pulse duration squared on resonance. To follow the subsequent return of population, keep both amplitudes coupled. Consider an isolated pair of levels driven by a monochromatic field with a nearly resonant frequency. Use the rotating-wave approximation, justified when the detuning and coupling are both small compared with the carrier frequency. Let \(\Delta\) be the angular detuning and \(\Omega\) the resonant angular Rabi frequency. During a square pulse the rotating-frame Hamiltonian, up to an identity term, is
The square follows because the two Pauli matrices anticommute. In the exponential propagator the even powers of \(H_R\) therefore multiply the identity and the odd powers multiply \(H_R\). Sum the two Taylor series with \(\Omega_e=\sqrt{\Omega^2+\Delta^2}\):
Starting in the lower bare state, only \(\sigma_x\) contributes to the upper-state amplitude. Its squared magnitude is
On resonance a pulse area \(\Omega t=\pi\) transfers the entire population; twice that duration returns it to the lower state. At short times the leading term is \(\Omega^2t^2/4\), recovering perturbation theory. Detuning both speeds up the oscillation and reduces its attainable maximum. These two signatures help distinguish mistuning from a change in drive strength.
Worked example
Design a population inversion pulse
Change the inputs and investigate this derivation.
If \(\Omega/(2\pi)=2.00\) MHz, the resonant inversion time is \(\pi/\Omega=0.250\) microseconds. A \(0.125\) microsecond pulse gives \(P_e=0.500\). Holding the drive on for \(0.500\) microseconds instead gives zero in the ideal model. The source supplies and subsequently receives energy during a reversible oscillation.
Second application
Infer the mistuning from an incomplete oscillation
Change the inputs and investigate this derivation.
Suppose the same drive produces maxima of \(0.640\) and full population oscillations repeat every \(0.400\) microseconds. The period gives
The maximum gives \(\Omega/\Omega_e=\sqrt{0.640}=0.800\), recovering the calibrated \(2.00\) MHz drive. The detuning magnitude is \(\sqrt{2.50^2-2.00^2}=1.50\) MHz in ordinary-frequency units. A population trace alone leaves its sign undetermined.
How a time-dependent perturbation transfers population
For a time-independent Hamiltonian \(H_0\) the energy components of a state accumulate phases without changing populations. Let a weak applied perturbation \(V(t)\) act for a known interval. Prepare the unperturbed eigenstate \(|i\rangle\) at \(t=0\) and write \(|\psi(t)\rangle=\sum_n c_n(t)e^{-iE_nt/\hbar}|n\rangle\). The interaction-picture amplitudes isolate changes beyond the free phases. Substitution into Schrödinger’s equation and projection onto \(|f\rangle\) give
At first order retain \(c_i=1\) on the right-hand side. For \(f\ne i\) the resulting amplitude is the Fourier component of the perturbation at the transition frequency,
An energetically resonant drive still fails to populate a state if the coupling matrix element vanishes by symmetry. The operator describing the drive is as important as its frequency.
A rectangular pulse
Let \(V_{fi}(t)=V_{fi}\cos(\omega t)\) for \(0<t<T\), with an upward transition so \(\omega_{fi}>0\). Splitting the cosine into exponentials gives frequencies \(\omega_{fi}-\omega\) and \(\omega_{fi}+\omega\). Near resonance, for a pulse lasting many carrier cycles, the rapidly oscillating sum-frequency term contributes little. With detuning \(\Delta=\omega_{fi}-\omega\) the remaining integral gives
At exact resonance all contributions build with the same phase, so for a weak short pulse probability grows quadratically in time. The first zeros occur at \(|\Delta|=2\pi/T\), or ordinary-frequency detuning \(1/T\). The line shape measures coherent addition over the finite observation time. It can be broad even when the isolated energy levels have negligible natural width.
Calibrate a pulse
Take a 2.00 ms rectangular pulse with \(|V_{fi}|/\hbar=200\) rad/s. The resonant transition probability is
At 250 Hz detuning the sinc argument is \(\pi/2\), leaving probability \(0.0162\). The first zeros lie 500 Hz on either side. Doubling pulse duration at the same coupling predicts four times the peak probability and half the first-zero spacing within the weak-drive approximation. A measurement can test both the area dependence and frequency scaling.
Once the predicted population is no longer small, depletion of the initial level removes the first-order approximation. For an isolated resonantly driven two-state system the rotating-wave solution is \(\sin^2(|V_{fi}|T/(2\hbar))\), describing coherent population transfer and return. Lifetime decay or field fluctuations introduce still other envelopes. Varying pulse duration at fixed drive strength distinguishes finite-time broadening from linewidths that persist as the pulse is lengthened.
The pulse envelope provides an additional independent control. Replacing the sudden rectangular turn-on and turn-off with smooth edges reduces spectral sidelobes because the Fourier transform of the smoother envelope falls faster away from resonance. Peak transfer at resonance, in the weak-drive regime, depends on the time integral of the drive envelope. Two pulses of different shapes can therefore have the same low-power resonant transition probability yet excite a nearby unwanted level with different probabilities. Specifying duration alone would be insufficient to reproduce such a measurement.
From a finite pulse to Fermi’s golden rule
An isolated resonant final state initially collects amplitude proportional to time. A dense set of final states can instead produce a nearly constant total transition rate. To see the change, let a weak drive connect one initial state to levels around energy \(E_\star=E_i+\hbar\omega\). Denote the matrix element of the resonant Fourier component by \(M\). For a cosine drive it contains the factor of one half. First-order time integration over a square pulse gives a phase times \((Mt/\hbar)\,\mathrm{sinc}[(E-E_\star)t/(2\hbar)]\), where \(\mathrm{sinc}(u)=\sin(u)/u\).
The different final states are orthogonal, so their probabilities add. If the density \(\rho(E)\) counts accessible final states per unit energy, and \(\rho\) and \(M\) vary slowly over the line width,
Set \(u=(E-E_\star)t/(2\hbar)\). Away from a band edge one can extend the integral across the line and use \(\int_{-\infty}^{\infty}\mathrm{sinc}^2u\,du=\pi\). One power of time cancels against the narrowing energy interval, leaving \(P(t)\simeq\Gamma t\) with \(\Gamma=2\pi |M|^2\rho(E_\star)/\hbar\). This intermediate-time result assumes many final levels within the line and little depletion of the initial state. For a small isolated system the long-time dynamics can resolve individual levels again.
As a numerical example, use \(M=0.500\,\mathrm{\mu eV}=0.000500\,\mathrm{meV}\), \(\rho=1000\,\mathrm{meV^{-1}}\) and \(\hbar=0.6582\,\mathrm{meV\,ps}\). The rate is \(0.00239\,\mathrm{ps^{-1}}\), or a transition probability of \(0.0239\) after \(10.0\,\mathrm{ps}\). The first zero lies \(2\pi\hbar/t=0.414\,\mathrm{meV}\) from resonance, spanning about 414 level spacings on each side for a locally uniform density. The small transition probability and dense spectrum are distinct checks on the approximation.
Separate phase accumulation from the drive pulses
A single spectroscopy pulse ties spectral resolution to its own duration. The Ramsey method separates two short coherent pulses by an interval of free evolution. Work with two isolated states \(|g\rangle,|e\rangle\) in the rotating frame of a stable reference. Approximate each pulse as short compared with the free interval and strong enough to rotate the Bloch vector by \(\pi/2\) about the same transverse axis. Ignore relaxation and pulse detuning during the rotations. Starting in \(|g\rangle\), the first pulse prepares \((|g\rangle-i|e\rangle)/\sqrt2\) for the chosen pulse phase.
Over free interval \(T\) the excited component gains relative phase \(e^{-i\Delta T}\), with \(\Delta=\omega_{eg}-\omega_{\rm ref}\). The second pulse mixes both paths to \(|e\rangle\). Using the rotation matrix \(R_x(\pi/2)=(I-i\sigma_x)/\sqrt2\) gives
A controllable phase on the second pulse shifts these fringes; on exact resonance two aligned pulses complete a \(\pi\) rotation and transfer all population. For a statistical mixture with the same half populations after pulse one, the two contributions to the final probability have no mutual phase and give one half regardless of delay. Thus the separated-pulse signal measures phase retained between pulses, even when no energy transfer takes place during most of the sequence.
Measure a small reference-frequency error
Take a free interval of 2.00 ms. Adjacent maxima occur at ordinary detunings separated by \(1/T=500\) Hz. The first minimum on either side occurs at 250 Hz. The separation of the two half-height points immediately surrounding resonance is
These three figures refer to different linewidth or spacing conventions and should be identified before comparing experimental reports.
Set the second pulse phase so that the calibrated signal near zero detuning is \(P_e=[1+\sin(2\pi\delta\nu T)]/2\). A measured \(P_e=0.600\) gives \(\delta\nu=\arcsin(0.200)/(2\pi T)=16.0\) Hz on the branch nearest the reference. This setting is more sensitive to small signed frequency errors than the top of a fringe, where the first derivative vanishes. A first scan or a shorter free interval is needed to identify which repeated fringe is being tracked.
If the transverse coherence decays during free evolution, observed fringe amplitude is multiplied by the coherence factor, often approximated by \(e^{-T/T_2}\). Extending the delay narrows fringe spacing but eventually reduces contrast. Measuring two phase settings in quadrature can separate an actual phase shift from a loss of visibility due to decoherence or pulse-area errors.
The frequency sensitivity per detected particle can also be estimated. At half population an ensemble of \(N\) independent measurements has standard error \(1/(2\sqrt N)\) in the estimated excited fraction. On the central quadrature slope \(dP_e/d\delta\nu=\pi T\), giving frequency uncertainty approximately \(1/(2\pi T\sqrt N)\) for ideal contrast. With the 2.00 ms delay and ten thousand independent detections this is about 0.80 Hz for a single ensemble. Imperfect contrast reduces the slope, and an unknown phase offset adds a systematic error that collecting more particles alone cannot remove.
Separate detuning from shortened observation time
Start a two-level system in its ground state, apply a monochromatic drive of resonant Rabi frequency \(\Omega\), and neglect relaxation. In the rotating-wave approximation detuning \(\delta\) changes the oscillation frequency to \(\sqrt{\Omega^2+\delta^2}\) and reduces its maximum transfer.

Try it · Rabi
Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.
Read values from the plot
| Time / resonant Rabi period | Detuning / coupling = 0 | Detuning / coupling = 0.5 | Detuning / coupling = 1 |
|---|---|---|---|
| 0 | 0 | 0 | 0 |
| 0.75 | 0.5 | 0.18881 | 0.01794 |
| 1.5 | 1 | 0.57699 | 0.069184 |
| 2.25 | 0.5 | 0.79809 | 0.14638 |
| 3 | 1.3498e−31 | 0.64338 | 0.23844 |
Boundary conditions that carry a current around a ring
An electron on an ideal narrow ring can sustain current in a stationary state. Work out how the topology of its configuration space and a magnetic flux through the hole select the allowed currents.
Recover the allowed state space from a boundary term
Wrap a coordinate \(s\) of length \(L\) around the ring. The points \(s=0\) and \(s=L\) label the same physical place. For a uniform one-dimensional kinetic operator, integration by parts shows that the difference between \(\langle\phi,H\psi\rangle\) and \(\langle H\phi,\psi\rangle\) is proportional to
Periodic values and periodic first derivatives make this expression vanish for any two admissible states. They also make the probability current continuous at the join. A plane wave \(e^{iks}/\sqrt L\) then requires \(kL=2\pi n\) with integer \(n\). The labels \(n\) and \(-n\) have equal energy at zero flux but circulate oppositely. A real combination of the pair has zero net current. An energy measurement on its own does not tell us which combination was prepared.
Put flux through the hole
For a particle of charge \(q\), the kinetic momentum along the ring is \(-i\hbar\partial_s-qA_s\). Choose a constant tangential vector potential \(A_s=\Phi/L\) giving the required circulation \(\oint A_s ds=\Phi\). Define signed flux \(\varphi=q\Phi/h\). Periodic plane waves remain eigenfunctions, while their kinetic momenta and energies now change:
A gauge transformation can eliminate the constant \(A_s\) locally. It multiplies a wavefunction by a phase whose value after one circuit differs from its initial value by \(e^{-2\pi i\varphi}\) in this gauge. The transformed wavefunction must carry that twist at the join. Imposing both zero vector potential and unchanged periodicity would discard the physical flux dependence. Increasing \(\varphi\) by one reorders the spectrum by a shift of the integer labels.
Work out what a current measurement sees
One particle of velocity \(v=p_{\rm kin}/m\) goes around the ring in a time \(L/|v|\). The signed charge passing a fixed section per unit time is \(I=qv/L\). Differentiating \(E_n\) at fixed \(n\) gives the same result:
Take \(\varphi=0.30\). In units of \(E_L\), the \(n=0\) energy is 0.09 and the \(n=1\) energy is 0.49. The currents in units of \(qh/(mL^2)\) are −0.30 and +0.70 respectively. A probe that selects the lower-energy branch here sees a circulating state even though its probability density is uniform around the ring.
At \(\varphi=0.50\) the two energies agree at \(0.25 E_L\). Following a given eigenstate through this crossing and allowing a system to relax into its lowest energy at every flux describe different experiments. An ideal isolated perfectly uniform ring conserves its angular momentum label. Weak imperfections or a reservoir can change the populations and modify the behaviour near degeneracy.
Inspect the neighbouring branches
Change the signed flux continuously. Compare the slope of the branch containing \(n=0\) with its current. Predict where the lowest pair changes ordering and check that the complete set repeats with unit flux.
Tutorial on a ring of another size
Double the circumference at fixed mass and flux while preparing the same integer state. Predict the changes of its wave number, energy and current.
Work through the solution
The canonical and kinetic wave numbers each halve because the integer label and signed flux are fixed. \(E_L\) scales as \(L^{-2}\), and so does the current unit \(qh/(mL^2)\). Energy and current both fall to one quarter. The flux period \(h/|q|\) stays unchanged.
A ring with fixed flux is enlarged to twice its original circumference without changing the particle mass. How do energy gaps and branch currents change? Does the location of a crossing in flux move?
Work through the solution
\(E_L=h^2/(2mL^2)\) falls by a factor of four. The current scale \(qh/(mL^2)\) falls by the same factor. The signed flux variable contains no circumference when total flux is held fixed, so crossings stay at half-integer flux. Holding the magnetic field fixed as ring area grows would instead change the enclosed flux.
At \(\varphi=0.50\), prepare an incoherent mixture with equal populations on \(n=0\) and \(n=1\). Calculate its current and energy. Can observing zero average current distinguish this mixture from zero flux?
Work through the solution
The currents are opposite, each of magnitude half the current unit, and the mean vanishes. Both energies are \(0.25E_L\). A zero-flux ground state also has zero current, but its energy is zero in the same calibration. Spectroscopy or a change of population separates the two cases.
Further reading · Tong, Particles in Magnetic Fields, gauge transformations and Aharonov–Bohm effect · Fließbach, Quantenmechanik, Eigenwerte und Eigenfunktionen.
Adiabatic following and a finite sweep through an avoided crossing
Two unperturbed energies cross as a control rises. A nonzero coupling opens a gap. Whether a prepared particle follows the lower energy through the crossing depends on how quickly the eigenvectors rotate compared with the dynamical phase they accumulate.
Find the gap and the rotation rate
Let \(\hbar=1\) temporarily, with Hamiltonian \(H(t)=\begin{pmatrix}vt/2&g\\g&-vt/2\end{pmatrix}\), \(v>0\), \(g>0\). The fixed basis is called diabatic because each basis vector keeps its identity as the detuning \(vt\) changes sign. Squaring the Hamiltonian gives \([(vt/2)^2+g^2]I\); its energies are \(\pm h(t)\) with \(h=\sqrt{(vt/2)^2+g^2}\). The minimum gap is \(2g\). The corresponding Bloch axis points along \((g,0,vt/2)\); write its polar angle as \(\theta=\operatorname{atan2}(2g,vt)\).
Differentiating the angle gives
A spinor aligned with this axis rotates through half its geometric angle in Hilbert space. The magnitude of the off-diagonal derivative coupling is \(|\dot\theta|/2\), largest at the crossing where it equals \(v/(4g)\). Comparison with the minimum gap frequency \(2g/\hbar\) gives a local adiabatic ratio \(\hbar v/(8g^2)\). A slow sweep or large coupling suppresses transitions between instantaneous energy states. Following the lower adiabatic state exchanges the two fixed basis labels across the crossing.
Derive the fast-sweep scale independently
In the interaction picture of the diagonal part, the energy difference \(vt\) gives an accumulated relative phase \(vt^2/(2\hbar)\). First-order perturbation theory gives a transition amplitude proportional to \((g/\hbar)\int_{-\infty}^\infty e^{ivt^2/(2\hbar)}dt\). The magnitude of this Fresnel integral is \(\sqrt{2\pi\hbar/v}\), obtained by continuing the convergent Gaussian integral from a positive real damping parameter. The leading probability to change fixed basis states is therefore \(2\pi g^2/(\hbar v)\), valid only when small. The exact infinite linear-sweep Landau–Zener solution resums this dependence: the probability of retaining the initial diabatic label is \(\exp[-2\pi g^2/(\hbar v)]\). It refers to endpoints asymptotically far from the avoided crossing with constant coupling and no decoherence.
For \(g=0.5\) and \(v=1\) in units where \(\hbar=1\), the infinite-sweep retention probability is
Halving \(v\) squares it to 0.0432. The slow sweep therefore gives greater transfer between fixed basis states while preserving the lower-energy identity more faithfully. This distinction prevents reversing the interpretation of a measured probability.
Evolve a finite preparation numerically
Prepare the instantaneous ground state at detuning \(vt=-10\) and finish at \(+10\). Over each short step freeze \(H\) at its midpoint. Since \(H^2=h^2I\), the constant-step propagator is exactly \(\cos(h\Delta t)I-i\sin(h\Delta t)H/h\) in the chosen units. The product is unitary up to roundoff; finite time resolution still changes accumulated phases. Compare the population of the original fixed basis state with its population in the instantaneous ground state. Their separation through the crossing directly shows where ideal adiabatic following fails. The calculated final population can differ from the infinite-sweep expression because of endpoint mixing and phases.
Tutorial on measurement choices
The coupling doubles while all else is fixed. How must the sweep rate change to leave the ideal infinite-sweep probability unchanged? Does a sweep over fixed detuning endpoints remain exactly equivalent?
Work through the solution
Keep \(g^2/v\) fixed by multiplying \(v\) by four. The infinite-sweep exponent is unchanged. At fixed endpoints the ratios \(|vt|/g\) at preparation and readout are now smaller, so the finite endpoints are less asymptotic. Their state mixing can change the observed result.
At zero detuning an energy measurement finds the lower eigenvalue with certainty. What would an immediate measurement in the fixed basis return?
Work through the solution
The lower eigenstate there is \((1,-1)/\sqrt2\) in the chosen convention. Each fixed-basis outcome therefore occurs with probability one half. Certainty in the instantaneous energy is compatible with maximal uncertainty concerning the diabatic label.
Further reading · Tokmakoff, time-dependent quantum mechanics and Landau–Zener transitions · Rubbmark and colleagues, experimental passage through an avoided crossing.
When a periodic dielectric has no propagating Bloch wave
Fields and the response of matter
Derive a band gap using two lossless transparent materials and distinguish evanescent Bloch propagation from absorption of optical power.
Construct a unit cell whose waves interfere
Stack two transparent, lossless, nonmagnetic dielectrics periodically in one dimension. Their refractive indices are \(n_1,n_2\), their physical thicknesses \(d_1,d_2\), and the period \(a=d_1+d_2\). Work at normal incidence, so polarisation directions are equivalent for isotropic layers. Each separate material admits a propagating wave at the chosen optical frequency, yet the periodic stack may not. The effect comes from coherent interface reflections, not from a negative refractive index or an absorptive constituent.
Describe the local field by its tangential electric and magnetic components. Propagation through one homogeneous layer connects them by a \(2\times2\) transfer matrix with diagonal \(\cos\phi_j\), off-diagonal terms proportional to \(iZ_j\sin\phi_j\) and \(i\sin\phi_j/Z_j\), where \(\phi_j=\omega n_jd_j/c\) and \(Z_j=Z_0/n_j\). Changing the chosen propagation direction or time convention may reverse the two imaginary signs together. The real trace and unit determinant of the cell matrix below are unaffected.
Read the dispersion relation from the trace
At an interface both tangential components are continuous in the absence of imposed sheet currents. Multiply the two propagation matrices to form one cell. Its determinant is one because each layer's determinant is
Thus the two eigenvalues are reciprocal. For a Bloch mode they are \(e^{\pm i k_Ba}\) on a pass band. Taking half the trace gives
When the right side lies between −1 and 1 a real Bloch phase exists. If its magnitude exceeds one, a decaying and a growing Bloch factor replace a pair of unit-modulus factors. For a bounded excitation of a semi-infinite stack choose the decaying direction. The attenuation per cell is \(\operatorname{arcosh}|\operatorname{trace}(M)/2|\). A lossless semi-infinite crystal in a stop band reflects incident power. Spatial attenuation of a Bloch amplitude in this region is compatible with zero volumetric heat production.
Obtain a quantitative stop-band width
Choose \(n_1d_1=n_2d_2=\lambda_0/4\). Writing \(s=\omega/\omega_0\), both layer phases are \(\phi=\pi s/2\). At \(s=1\) the half trace is \(-\tfrac12(n_2/n_1+n_1/n_2)\). Recognising \(\cosh(\log r)=(r+r^{-1})/2\) gives centre attenuation \(|\log(n_2/n_1)|\) per cell. For \(n_1=1.5,n_2=2.0\) this is 0.2877, so a decaying eigencomponent has amplitude factor 0.75 per cell. This statement about an eigencomponent should not be confused with the exact transmittance of a specific finite stack, which also depends on entrance and exit impedances.
The first gap edges obey half trace −1. With \(\cos^2\phi=1-\sin^2\phi\), solve for the edge sine or cosine. The two edge phases are symmetric about \(\pi/2\) and satisfy
Hence the fractional angular-frequency width is \((4/\pi)\arcsin(|n_2-n_1|/(n_1+n_2))\), about 0.183 for the example. The lowest gap width tends continuously to zero as index contrast vanishes. A gap in a plotted numerical spectrum at \(n_1=n_2\) would indicate an implementation or plotting problem.
Compare a frequency scan with a finite mirror
The graph plots half the transfer-matrix trace against normalised frequency and marks the admissible interval for a real Bloch phase. Change the index contrast first, keeping the layers quarter wave at the same reference frequency. The physical layer thickness adjusts in this family; it is a different experiment from changing a material while manufacturing all thicknesses fixed. Use the frequency control to read an attenuation exponent at the centre and just outside the gap.
At low frequency a wavelength spans many cells and a homogenised description can predict the long-wave speed. At the first gap the field changes phase by order one across a cell, exactly where the homogenisation scale separation fails. Conversely, an electromagnetic calculation showing multiple bands at very low frequency should be checked against a uniform-medium or long-wavelength effective-index limit. Compare a finite stack's reflection with the Bragg-mirror experiment. The bulk trace determines whether a propagating state can exist. A finite sample adds interference between boundaries and possible surface or defect effects.
Tutorial
If the two refractive indices become equal, simplify the trace formula for arbitrary thicknesses.
Work through the solution
The impedance factor becomes one, so the half trace is \(\cos\phi_1\cos\phi_2-\sin\phi_1\sin\phi_2=\cos(\phi_1+\phi_2)\). It never exceeds unit magnitude. Labelling a uniform medium by an artificial period folds the dispersion into zones but does not create a physical gap.
At the central quarter-wave frequency for index ratio 2, how many periods reduce a decaying Bloch component's amplitude by a factor of 100?
Work through the solution
The amplitude factor per cell is
Require \(2^{-N}\le0.01\), giving \(N\ge7\). A prediction for transmitted optical power also needs termination and impedance matching.
A measured stack exhibits both a transmission minimum and measurable heating. Can the minimum be attributed entirely to a band gap?
Work through the solution
A lossless band gap can reflect power without heating. Measure reflected and transmitted flux under consistent normalisation, then infer absorption from \(1-R-T\) after accounting for diffuse scattering and other exit channels. The bulk stop-band model and material absorption can coexist.
Compare with band calculations
MIT's mathematical nanophotonics course computes full periodic Maxwell modes. The one-dimensional trace above is a small benchmark with known pass and stop boundaries that a numerical eigenproblem should reproduce.
Measuring magnetic core loss by a hysteresis loop and by calorimetry
Electromechanics, optics and measurement
A closed loop on a graph of magnetic induction against field encloses an area with units of energy per unit volume. A thermometer measures kelvins. Bring these two observations onto the same scale, account for the winding heat, and determine when the two experiments actually test the same material loss.
Infer the field and the induction from independent windings
Wind a toroidal specimen with a primary winding of \(N_p\) turns and a lightly loaded pickup of \(N_s\) turns. Let \(A\) be the representative iron cross-sectional area, \(\ell\) the mean magnetic path length and \(V_c=A\ell\) the magnetic volume. Neglect a gap and leakage initially. Ampère's law around a path through the core gives
This relation is accurate when the toroid is slender enough that the spread of path radii is small and the pickup current is negligible. In a thick toroid \(H(r)=N_pi_p/(2\pi r)\), so one point on a nominal loop can actually represent a range of local field values.
Faraday's law supplies the second observable. Choose winding polarity so the reported voltage is
Integrating the voltage gives the change in cross-section-averaged magnetic induction. The pickup cannot determine a constant induction offset, because static flux induces no voltage. A closed loop area is insensitive to adding a constant to \(B\) or \(H\), but a dc offset in the voltage integrates into a time-dependent ramp and prevents the reconstructed trajectory from closing. In steady periodic operation one can subtract the voltage mean over a complete period before integration. Applying that correction to a genuinely evolving magnetisation process would remove part of a real flux change.
Multiply the two measured field quantities in the appropriate order. The field work supplied per unit material volume on a small induction change is \(H\,dB\). The source term associated with the magnetising flux is \(i_p v_{p,{\rm induced}}\,dt\). Using \(v_{p,{\rm induced}}\simeq(N_p/N_s)v_s\), its value is
Integrating around a settled cycle gives the magnetic loss
The field can absorb positive work and return some of it later in the same cycle. The area measures the algebraic remainder. Reversing the polarity of a single signal flips the loop orientation. A passively heated specimen must receive positive net energy when signs are defined for power entering the core. Simply taking the absolute value of all instantaneous products would count reversible storage twice and can grossly overestimate the heat.
Work an elliptical loop from time-domain signals
Suppose a nearly sinusoidal field is \(H=H_p\cos\omega t\) and the induction lags it by a positive angle \(\delta\), \(B=B_p\cos(\omega t-\delta)\). Differentiate the latter and multiply by \(H\). Over one cycle \(\cos\omega t\sin\omega t\) averages to zero, and \(\cos^2\omega t\) averages to one half. The resulting mean power density is \(\omega H_pB_p\sin\delta/2\), giving \(\oint H\,dB=\pi H_pB_p\sin\delta\). With zero lag the two signals trace a line and the area vanishes, even if the peak values are large. A saturation-distorted loop need not be elliptical; the original time integral remains valid with synchronised data.
Take \(H_p=120\,{\rm A/m}\), \(B_p=0.200\,{\rm T}\) and \(\delta=12^\circ\). The energy per cycle and volume is \(15.68\,{\rm J/m^3}\). A toroid with \(\ell=0.20\,{\rm m}\), \(A=2.0\times10^{-4}\,{\rm m^2}\) and \(V_c=40\,{\rm cm^3}\) dissipates \(0.627\,{\rm mJ}\) per cycle. At \(f=200\,{\rm Hz}\) its power is \(0.125\,{\rm W}\). With \(N_p=100\), the necessary current peak is \(0.240\,{\rm A}\). With \(N_s=50\), the pickup voltage has peak \(N_sA(2\pi f)B_p=2.51\,{\rm V}\). These last two predictions allow the raw oscilloscope traces to be checked before a calculated loss in watts is trusted.
For sampled periodic data use \(w=\sum_n(H_n+H_{n+1})(B_{n+1}-B_n)/2\), including the segment from the last point back to the first. This trapezoidal line integral computes an oriented polygon area. Plot the starting and ending points before adding the closing segment. Connecting widely separated endpoints by hand hides drift and can generate a fictitious wedge whose area depends on acquisition timing. Repeat at higher sampling rates to see whether corners or switching features carry appreciable extra area. When a periodic excitation has harmonics the time increment must resolve the highest significant harmonic in both measured signals.
Compare a thermal measurement with the magnetic area
Consider first a calorimeter that receives heat only from the core. Let the heat capacity of specimen, holder and sensor be \(C_{\rm eff}\). Let the leakage conductance to an ambient bath be \(G\), and let \(\Delta T=T-T_a\). The thermal balance \(C_{\rm eff}\dot{\Delta T}=P_c-G\Delta T\) predicts a steady offset \(P_c/G\) and an initial heating slope \(P_c/C_{\rm eff}\). A small thermometer lag or poor thermal contact can make the earliest measured slope misleading even though environmental losses are then small. A separate electrical heater placed where the core deposits its heat can calibrate the effective thermal response.
For \(C_{\rm eff}=20\,{\rm J/K}\), \(G=0.015\,{\rm W/K}\), and a \(2.0\,{\rm K}\) rise above ambient, the magnetic loss \(0.125\,{\rm W}\) would give a slope of about \(0.00477\,{\rm K/s}\). The heat already leaking to the bath is \(0.030\,{\rm W}\), too large to discard in a ten-percent comparison. If the winding is inside the same calorimeter, its Ohmic heat must enter the balance as well. With primary resistance \(1.50\,\Omega\) and the computed sinusoidal current, winding heating is
The expected slope of the combined package at the same temperature is now \(0.00693\,{\rm K/s}\). Subtraction of winding heat recovers the core result only when the estimated resistance represents the winding at its operating temperature and frequency.
A thermal estimate drawn from a whole interval is often more robust than a derivative from two adjacent temperature samples. Integrating gives
Divide by the duration for mean power, then remove other measured heat sources. A drifting ambient must be recorded explicitly because the calorimeter stores energy relative to its own absolute temperature. If the core and coil equilibrate slowly with each other, a single fitted heat capacity can depend on the fitting time window. A two-temperature model or a longer dwell then supplies an independent diagnostic.
Separate reversible exchange from hysteretic and induced currents
A single measured loop at finite frequency gives the total energy dissipated by the core at that prescribed waveform and temperature. The loop can include irreversible domain processes, eddy currents and other rate-dependent effects. It does not by itself split these contributions. To probe their different scaling hold the peak induction and waveform shape fixed, then change frequency. Under a restricted low-frequency model the quasi-static hysteresis energy per cycle is approximately constant, while classical thin-lamination eddy-current power scales as \(f^2B_p^2\). Its energy per cycle therefore scales roughly as \(f\). Plotting the measured loss per cycle and volume against \(f\) tests whether such an intercept-plus-slope description fits the chosen range.
Suppose the area is \(12\,{\rm J/m^3}\) at \(100\,{\rm Hz}\) and \(20\,{\rm J/m^3}\) at \(300\,{\rm Hz}\), at the same peak induction. A straight line gives intercept \(8\,{\rm J/m^3}\) and slope \(0.040\,{\rm J\,s/m^3}\). It predicts \(16\,{\rm J/m^3}\) at \(200\,{\rm Hz}\), near the elliptical-loop calculation. Two points always determine a line. A third and fourth frequency, together with uncertainties, are required to test the law. Different losses can share similar frequency scaling over a short interval, and temperature-dependent conductivity can bend a nominally simple curve.
Use the pickup to reject the reversible part of terminal power
Measuring primary terminal voltage and current with a power analyser provides a separate electrical route to loss, but the wanted number can be a small difference between terms. The applied voltage contains winding resistance, induced magnetising voltage, leakage-inductance voltage and possible parasitic contributions. In steady periodic operation the energy stored in a fixed linear leakage inductance returns after each cycle, while winding resistance dissipates energy permanently. The secondary pickup preferentially measures the core-linked flux. Forming \(p_c(t)=(N_p/N_s)i_p(t)v_s(t)\) and averaging over a full cycle estimates core power without directly including the primary's copper voltage drop. It relies on both windings linking the same relevant flux and on negligible power drawn by the pickup.
For the elliptical example the primary magnetising voltage has peak \(5.03\,{\rm V}\) and leads the induction by ninety degrees. Its phase relative to the current is
The core branch's apparent power is \(V_{\rm rms}I_{\rm rms}\approx0.603\,{\rm VA}\); its mean dissipative part is about \(0.125\,{\rm W}\), and the reactive part is about \(0.590\,{\rm var}\). Only the mean part contributes net heating of the magnetic volume. Including the winding voltage adds about \(0.043\,{\rm W}\) of real power to the terminal reading. A simple product of peak current and peak secondary voltage, without the turns ratio, factor one half and phase factor, has no reason to agree with either measured loss.
Consider a nearly ideal core with the same peak signals but a lag of only one degree. Its loss is about \(10.5\,{\rm mW}\), while the much larger reversible power exchange is almost unchanged. A time offset of \(10\,\mu{\rm s}\) at \(200\,{\rm Hz}\) adds \(0.72^\circ\), causing a relative loss error of approximately \(72\%\) for that small lag. Calibrate the relative channel delays using a reference signal through the actual current transducer and voltage chain, including their filters. Adjusting traces on screen until a core loop appears narrow assumes the very loss one is trying to measure. A synchronous measurement over many periods suppresses random noise but does not remove a persistent delay bias.
Test reconstruction on a waveform with a third harmonic
Let \(H(t)=H_1\cos\omega t+H_3\cos3\omega t\) while \(B(t)=B_1\cos(\omega t-\delta_1)+B_3\cos(3\omega t-\delta_3)\). With these definitions \(\delta_n\) is the phase lag of the \(n\)th harmonic in its own sinusoid. Multiplying \(H\) by \(\dot B\) and integrating over an integer number of fundamental periods eliminates products of different harmonics. Each surviving harmonic contributes the number of its own cycles in one fundamental period. The area per fundamental period is therefore \(\pi[H_1B_1\sin\delta_1+3H_3B_3\sin\delta_3]\). This identity tests whether a numerical area calculation tracks the full waveform. It does not assume that a real material is linear; here the two signals are supplied as measured periodic functions.
Use the earlier fundamental values and add \(H_3=20\,{\rm A/m}\), \(B_3=0.030\,{\rm T}\) and \(\delta_3=30^\circ\). The third harmonic contributes \(2.83\,{\rm J/m^3}\) in each fundamental period. This represents an additional \(0.0226\,{\rm W}\) for the chosen specimen and frequency. A fundamental-only sine fit would miss nearly fifteen percent of the resulting total area. An apparent jagged loop can also arise from asynchronous sampling or an offset. Distinguish genuine harmonics by checking that they are phase locked to the drive and persist under a change in sampling rate and analogue bandwidth.
Sweep phase and read the oriented loop
The live experiment reconstructs the \(H,B\) trajectory and compares it with a zero-lag reference. It uses the same peak field and induction for the two curves. At fixed peaks changing frequency leaves an assigned phase lag and therefore the prescribed energy per cycle unchanged, while watts rise with the number of cycles per second. A real core can change its lag and waveform with frequency; the graph separates this independent variable so that the meaning of the two scaled quantities is clear. Add a timing offset and predict the direction of the area error before checking its reported size. Near zero lag even the direction of an apparent loop can be controlled by a small electronic offset.
Two toroids are made of the same nominal material with equal cross sections but different mean path lengths. How should a result reported only as watts be compared?
Work through the solution
Determine actual magnetic volume for each toroid and calculate the energy per unit volume per cycle, \(P/(fV_c)\). Also check that both experienced the same induction waveform, frequency and temperature. Equal primary currents need not give equal field when the path lengths differ; equal primary applied voltages need not give equal core induction if turns, winding voltage drops or area differ. Reproducing the actual \(B(t)\) with feedback on the pickup is a more direct way to match excitation. Report dimensions and peak induction with the result so a reader can reconstruct what material condition was tested.
A saturated sample shows a small loop during a biased excitation that never crosses zero induction. Does the area formula still apply?
Work through the solution
A settled periodic minor loop encloses an area representing the net cyclic energy under exactly that bias and excursion. Adding a static induction offset does not change \(\oint H\,dB\), but the bias can alter the trajectory, differential permeability, and width of the minor loop itself. Do not infer the full major-loop energy from its area. The pickup returns only changes of induction unless an independent dc measurement or a known magnetic preparation supplies the offset. A bias winding may additionally heat the calorimeter, so include its measured power when comparing with thermal loss.
Tutorial on comparing two loss measurements
A data logger reports \(H_p\) and \(B_p\) correctly but adds an uncorrected \(10\,\mu{\rm s}\) delay to the induction channel. Estimate the fractional area error of the elliptical example.
Work through the solution
At \(200\,{\rm Hz}\) the extra apparent lag is
The reported area is multiplied by \(\sin(12.72^\circ)/\sin(12^\circ)\), about \(1.059\). An uncorrected delay of only one hundred-thousandth of a second overstates the core loss by about six percent. For a very low-loss specimen with much smaller physical lag, the same delay produces a far larger relative error.
A thermal run on the combined winding and core reports a slope \(0.0070\,{\rm K/s}\) at \(\Delta T=2.0\,{\rm K}\). Recover the core power and the volume-specific loss area at \(200\,{\rm Hz}\).
Work through the solution
Heat deposition in the package is
Subtract the estimated \(0.0432\,{\rm W}\) of winding heating to obtain \(0.1268\,{\rm W}\) in the core. Dividing by \(200\times4.0\times10^{-5}\) gives \(15.85\,{\rm J/m^3}\) per cycle. Its closeness to \(15.68\,{\rm J/m^3}\) should be evaluated against the uncertainties of heat capacity, thermal conductance, resistance, dimensions and electrical phase alignment.
Vary the magnetic circuit and identify the induction scale used by the specimen.
From a Coulomb orbit to the fine-structure multiplet
Quantum states, dynamics and measurement
Separate the hydrogenic Schrödinger equation, identify the origin of its large degeneracy and evaluate the three dominant relativistic corrections. The cancellation among them predicts an equality that spectroscopy can then test.
Separate centre-of-mass and relative motion
A light particle of mass \(m_e\) and charge \(-e\) interacts with a pointlike nucleus \(+Ze\) of mass \(M\). Use centre of mass \(\mathbf R=(m_e\mathbf r_e+M\mathbf r_N)/(m_e+M)\) and separation \(\mathbf r=\mathbf r_e-\mathbf r_N\). Expanding the sum of the two kinetic energies cancels all cross terms and gives a free centre-of-mass kinetic energy plus relative energy \(p^2/(2\mu)\), with reduced mass \(\mu=m_eM/(m_e+M)\). The relative potential is \(-k/r,\ k=Ze^2/(4\pi\epsilon_0)\). Its rotational symmetry implies \([H,L_i]=0\). Use a spherical harmonic \(Y_{lm}\) and write \(\psi=u(r)Y_{lm}/r\), so the probability in a thin radial shell is \(|u(r)|^2dr\) for angular harmonics of unit norm.
Substituting in the Laplacian separates the radial equation
For the regular three-dimensional solution \(u(0)=0\) and a bound state also decays at infinity. The centrifugal term is an effective energy associated with angular variation, not a separate force added by hand. For \(E<0\) define \(\kappa=\sqrt{-2\mu E}/\hbar,\ \rho=2\kappa r\), and \(a=\hbar^2/(\mu k)\). The small-radius behaviour of \(u\) is \(r^{l+1}\); the large-radius tail contains \(e^{-\kappa r}\). Pull both out by \(u=\rho^{l+1}e^{-\rho/2}v(\rho)\). Straight differentiation leaves
For \(v=\sum c_j\rho^j\), coefficient matching gives
The regular series must terminate to avoid an exponential asymptotic part that defeats the decaying prefactor. Thus \(1/(\kappa a)=n_r+l+1=n\), and \(E_n=-\mu k^2/(2\hbar^2 n^2)\). The normalised radial polynomials are associated Laguerre functions. This gives \(l=0,\ldots,n-1\) and \(\sum_l(2l+1)=n^2\) states before including spin. Rotational symmetry guarantees the degeneracy in \(m\), but a different central potential can split levels of different \(l\). The additional equality is specific to the Coulomb potential.
Calculate the radial moments needed for a correction
To isolate the leading relativistic corrections now take an infinitely heavy nucleus and set \(m=m_e\), \(a=\hbar^2/(mk)\). Including reduced mass in the leading energy is straightforward; a complete recoil correction to the fine structure requires additional interactions. A useful identity is \(\langle1/r\rangle=1/(an^2)\), obtained by differentiating \(E_n\) with respect to \(k\). The derivative of an eigenvalue equals the expectation of \(\partial H/\partial k=-1/r\) for the normalised eigenstate, which follows by differentiating \(H|\psi\rangle=E|\psi\rangle\) and cancelling terms using its adjoint. The same method applied to the radial centrifugal parameter yields \(\langle r^{-2}\rangle=1/[a^2n^3(l+1/2)]\) at fixed radial node count. Treat \(l\) as a continuously varied radial parameter during differentiation, then evaluate at its physical integer value.
For \(l>0\), the stationary radial force identity \(\langle dV_{\rm eff}/dr\rangle=0\) with vanishing endpoint term gives
Here \(V_{\rm eff}\) is the potential in the radial equation. The step uses sufficient behaviour of \(u,u'\) at the origin. For \(l=0\), the integral of \(r^{-3}\) diverges in an \(s\) state and the neglected endpoint term need not vanish. Substituting \(l=0\) formally into this expression would therefore be invalid. The contact density of an \(s\) state needed below is \(|\psi_{n00}(0)|^2=1/(\pi a^3 n^3)\), while states with \(l>0\) vanish at the origin.
Track the kinetic, spin–orbit and contact terms separately
The small parameter is \(Z\alpha=k/(\hbar c)\), with \(\alpha\) the fine-structure constant for \(Z=1\). Expand the relativistic dispersion about small momentum after subtracting rest energy: \(p^2/(2m)-p^4/(8m^3c^2)+\cdots\). For an energy eigenfunction \(p^2\psi=2m(E_n+k/r)\psi\), so \(\langle p^4\rangle=4m^2\langle(E_n+k/r)^2\rangle\) follows by taking the squared norm of \(p^2\psi\). Squaring the two operators as if \(p^2\) and \(1/r\) commute is unnecessary and would not be an operator identity. Inserting the first two radial moments gives
The Pauli expansion of the Dirac Hamiltonian adds \(H_{\rm so}=(1/[2m^2c^2r])V'(r)\mathbf L\cdot\mathbf S\) and the Darwin contact \(H_D=\hbar^2\nabla^2 V/(8m^2c^2)\). These are effective interactions through order \((Z\alpha)^4\); a purely nonrelativistic scalar equation does not generate the spin or contact term. For \(V=-k/r\), \(V'=k/r^2\) and \(\nabla^2 V=4\pi k\delta^3(\mathbf r)\). Thus the contact shifts only \(s\) states by \(+C_n\). For \(l>0\) insert the third inverse radial moment and the angular identity \(\mathbf L\cdot\mathbf S=\hbar^2[j(j+1)-l(l+1)-3/4]/2\). For the branch \(j=l+1/2\) the bracket is \(l\); for \(j=l-1/2\) it is \(-(l+1)\). Reducing fractions then gives
For \(l=0\) the spin–orbit operator vanishes and the Darwin term supplies the required difference. The sum in either case is
At fixed \(n\) the answer depends on \(j\) but no longer separately on \(l\). The cancellation cannot be inferred by merely attaching a phenomenological \(\mathbf L\cdot\mathbf S\) splitting to a nonrelativistic \(p\) state. In particular it predicts identical energies for \(2s_{1/2}\) and \(2p_{1/2}\) in this approximation, while \(2p_{3/2}\) lies higher. Radiative, recoil and finite-nuclear-size contributions can resolve some of these residual equalities. An experimentally resolved residual is evidence that the specified Hamiltonian omitted a physical term; it does not remove the cancellation inside that Hamiltonian.
Compare a small energy correction with a resolvable line
For hydrogen with \(mc^2\simeq511\,000\) eV and \(\alpha\simeq1/137.04\), the \(2p_{3/2}\)–\(2p_{1/2}\) interval is \(C_2/2\simeq4.53\times10^{-5}\) eV or \(10.95\) GHz. Compare with the leading \(n=2\) binding energy 3.40 eV. A small correction to total binding can give a prominent splitting when a measurement subtracts nearly equal large energies. Resolving it in a Fourier-limited time-domain experiment requires a coherent observation time at least of order the inverse frequency difference, here around 0.09 ns. Actual linewidths, lifetimes and pulse shapes affect how two spectral components can be distinguished.
A useful numerical audit is to fit the radial spectrum with three successive physical models. First solve the nonrelativistic radial boundary problem with the correct near-origin power and check that 2s and 2p converge toward the same energy. Then evaluate expectation values of the three corrections on those numerical states. Finally combine terms. Converged binding energies alone do not guarantee a converged contact density, which samples one spatial endpoint. A coarse radial grid can imitate an anomalous splitting between states which the analytical correction predicts to be equal. Check the origin slope of \(u_{n0}\), not only its norm or far tail.
Find where the electron is most likely to be detected
Confusion between spatial density and radial probability can lead to very different-looking descriptions of the same atom. For a hydrogenic ground state the normalised position-space wavefunction is \(\psi_{100}=(\pi a^3)^{-1/2}e^{-r/a}\). Its density is largest at the centre, but a thin spherical shell at radius \(r\) contains probability \(P(r)dr=4r^2 e^{-2r/a}dr/a^3\). The shell volume tends to zero at the origin. Differentiating \(\ln P\) gives \(2/r-2/a=0\), so the most likely shell radius is \(a\). The mean radius \(\int rP(r)dr=3a/2\) is different again because the shell distribution has a long tail. Neither number alone gives the probability that a finite spatial detector clicks.
Integrating the shell probability between zero and \(R\) gives
At the most likely shell radius \(R=a\), the probability inside is \(1-5e^{-2}=0.3233\), substantially less than one half. At \(R=2a\) it is
Taylor expansion at a small radius \(R\ll a\) gives \(4(R/a)^3/3\), equal to the ball volume times central density to leading order. This is the local scaling underlying finite-nucleus corrections to a contact-sensitive observable. Using the most likely radius as though the electron followed a thin circular orbit would give none of these cumulative probabilities, even though the same Coulomb length scale appears in the Bohr model.
For \(2s\) and \(2p\), both states have principal index two and the same leading energy. The \(2s\) radial amplitude is proportional to \((2-r/a)e^{-r/(2a)}\); its node at \(2a\) separates regions of opposite amplitude sign. The \(2p\) radial amplitude is proportional to \(r e^{-r/(2a)}\), with no positive-radius radial node. At short distance, the probability inside \(R\) scales as \(R^3\) for a nonzero \(s\) amplitude and as \(R^5\) for the \(p\) wave. A sufficiently localised weak perturbation near the nucleus can therefore split the nonrelativistic degeneracy even if it is rotationally symmetric. Rotational symmetry still protects equal shifts within the \(m\) multiplet. A radial perturbation and a field selecting a direction leave different patterns of protected degeneracy.
Diagonalise a degeneracy before expanding a weak electric field
The \(n=2\) Coulomb degeneracy creates a striking response to a weak uniform electric field along \(z\). In the purely nonrelativistic model with spin ignored the relevant spatial states are \(2s,\ 2p_0,\ 2p_{\pm1}\). The perturbation for an electron in electric field \(\mathcal E\hat z\) can be written \(e\mathcal E z\) up to an additive constant. Each unperturbed parity eigenstate has zero diagonal expectation of this odd operator. Applying ordinary nondegenerate first-order perturbation theory separately to all four states would therefore predict zero for every shift. But first-order perturbation theory in a degenerate manifold requires diagonalising the projected perturbation, including off-diagonal amplitudes.
The \(z=r\cos\theta\) operator has \(q=0\) and changes parity, so within \(n=2\) it couples only \(2s\) and \(2p_0\). Its angular matrix element between \(Y_{00}\) and \(Y_{10}\) is \(1/\sqrt3\). In a conventional phase convention the radial functions are \(R_{20}=(2-r/a)e^{-r/(2a)}/(2\sqrt2\,a^{3/2})\) and \(R_{21}=(r/a)e^{-r/(2a)}/(2\sqrt6\,a^{3/2})\). The remaining radial integral is \(\int r^3R_{20}R_{21}\,dr\). Setting \(s=r/a\) gives
Multiplying the angular factor gives \(-3a\). Rephasing one basis state would change this sign but leave all level shifts invariant.
The projected matrix has zero diagonal and off-diagonal \(-3ea\mathcal E\). Its symmetric and antisymmetric combinations have linear shifts \(\mp3ea\mathcal E\), while \(2p_{\pm1}\) remain unshifted to this order. The new states have definite first-order dipoles along opposite directions even though their zero-field basis states had zero dipoles. For \(a=5.29\times10^{-11}\) m and \(\mathcal E=1000\) V/m, an individual linear shift has magnitude \(1.59\times10^{-7}\) eV, corresponding to 38.4 MHz. This field is weak compared with the gross level separation, but whether the degenerate result is accurate in a real atom also depends on much smaller fine, hyperfine and radiative splittings. “Weak field” must specify the comparison energy.
A more precise two-state model retains a zero-field splitting \(\Delta\) between the coupled states. After subtracting their mean the Hamiltonian is \((\Delta/2)\sigma_z+d\mathcal E\sigma_x\), with \(d=3ea\) in magnitude. The energies are \(\pm\sqrt{(\Delta/2)^2+d^2\mathcal E^2}\). At \(d|\mathcal E|\ll|\Delta|\) the shift from each initial level is quadratic, \(\pm d^2\mathcal E^2/|\Delta|\), while at \(d|\mathcal E|\gg|\Delta|\) the slopes approach the linear-degenerate prediction. An observed crossover distinguishes a small unresolved internal splitting from a strictly zero projected dipole matrix element. Tracking energies over both positive and negative fields also tests for a stray dc field shifting the centre of the response.
Estimate a finite-size correction from the potential itself
The contact term derived from the Pauli expansion is not the same physical effect as giving the nucleus a finite charge radius. A simple electrostatic model separates the two scalings. Replace a point nucleus by a uniformly charged sphere of radius \(R_N\). Inside it the electron potential becomes
outside it is unchanged at \(-k/r\). The perturbation \(\delta V=k[1/r-3/(2R_N)+r^2/(2R_N^3)]\) is positive for interior points and zero at the surface. The smoothed potential is less attractive than the point law near the centre.
For an \(s\) state and \(R_N\ll a\), the unperturbed density varies little across the tiny sphere. First-order perturbation theory therefore gives
The first two radial integrals cancel and leave the \(R_N^2/10\) contribution before multiplication by \(4\pi\). Equivalently write \(\delta E=(2\pi/3)k|\psi(0)|^2\langle r_N^2\rangle\), since the uniform sphere has mean-square charge radius \(3R_N^2/5\). The result is a positive shift, decreasing binding. Corrections to the constant-density approximation involve additional powers of \(R_N/a\). A different microscopic charge distribution changes higher moments, while the leading small-size shift depends on its mean-square charge radius.
For a model \(R_N=1.0\) fm and the ordinary electronic hydrogen length \(a=5.29\times10^{-11}\) m, \(R_N/a=1.89\times10^{-5}\). For the ground state compare with \(|E_1|=k/(2a)\) and \(|\psi(0)|^2=1/(\pi a^3)\). The relative shift is \((4/5)(R_N/a)^2=2.86\times10^{-10}\), equivalent to roughly \(3.9\times10^{-9}\) eV. This illustrative uniform charge radius is input data of the model; do not equate it directly to a measured rms radius. For a heavier orbiting lepton a shorter Bohr radius increases the fractional sensitivity strongly. A complete precision spectrum would additionally include radiative and recoil effects and a realistic nuclear response. The present derivation isolates how one local perturbation scales and why \(s\) levels are especially sensitive.
Use dilation to audit stationary Coulomb energies numerically
A variational scaling argument gives a powerful independent check on a computed wavefunction. For any normalised trial state \(\psi\), define the normalised rescaling \(\psi_\lambda(\mathbf r)=\lambda^{3/2}\psi(\lambda\mathbf r)\). The Coulomb potential is homogeneous of degree minus one, and the gradient acquires a factor \(\lambda\). Its energy expectation is therefore
For an exact stationary bound state the energy functional is stationary with respect to norm-preserving variations, giving \(2\langle T\rangle+\langle V\rangle=0\) at \(\lambda=1\). Hence \(\langle T\rangle=-E,\ \langle V\rangle=2E\), consistent with the independently derived inverse-radius mean. The argument requires appropriate normalisation and boundary behaviour so the scaled trial function is allowed.
Suppose a numerical \(1s\) reconstruction yields \(\langle T\rangle=13.2\) eV and \(\langle V\rangle=-26.7\) eV. Its energy is \(-13.5\) eV, yet its virial residual is \(-0.3\) eV. Along the scale family the minimum occurs at \(\lambda_*=-\langle V\rangle/(2\langle T\rangle)=1.0114\), a slightly more concentrated state. The resulting energy reduction is only about 0.0017 eV, much smaller than the change in individual kinetic and potential terms. A small total-energy error can coexist with a noticeably incorrect radial scale because first-order energy errors cancel near a stationary solution. Monitoring separate expectation values, the virial residual and a contact-sensitive observable provides a more informative test of a numerical atomic calculation than reporting the total binding energy alone.
Distinguish orbital density from radial probability
Compare radial states at the same principal quantum number. Inspect their nodes before considering which additional interactions can lift their degeneracy.
Appraise a finite-grid Coulomb spectrum from convergence and degeneracy
To compute the radial Schrödinger eigenvalues directly, work in dimensionless radius \(s=r/a\), energy unit \(\hbar^2/(2ma^2)\), and write \([-d^2/ds^2+l(l+1)/s^2-2/s]u=\varepsilon u\). On a uniform grid \(s_j=jh\), use \(u_0=0\) and a far boundary \(u_{N+1}=0\). The diagonal approximation is \(2/h^2+l(l+1)/s_j^2-2/s_j\) and its neighbours are \(-1/h^2\). All potential terms are evaluated at positive interior grid points. Inserting an arbitrary finite value for \(1/s\) at the origin and treating it as an ordinary interior point changes the boundary approximation. A tridiagonal symmetric eigensolver returns orthogonal numerical vectors; physical radial norm is \(h\sum_j|u_j|^2\), so normalise appropriately before reconstructing spatial densities.
For \(l=0\) on an infinite grid the lowest mode permits an unusually informative exact lattice check. Try \(u_j=j q^j\) for \(0<q<1\). The finite-difference kinetic row divided by this trial value is \([2-q-q^{-1}]/h^2-(q-q^{-1})/(jh^2)\). Adding potential \(-2/(jh)\), the \(1/j\) coefficient vanishes when \(q^{-1}-q=2h\), or \(q=\sqrt{1+h^2}-h\). The eigenvalue is then
It tends to the exact continuum ground value \(-1\) as \(-1+h^2/4+O(h^4)\). This analytic discrete answer separates algebraic solver correctness from discretisation error for the exact same potential and boundary treatment.
At \(h=0.20\) the infinite-grid ground value is approximately \(-0.99020\); at \(h=0.10\) it is \(-0.99751\). Their errors differ by nearly a factor of four as predicted. A finite far wall shifts both energies further; repeat first at fixed \(h\) and increasing boundary radius to isolate that effect. An excited \(n=2\) state has a more extended tail and requires a larger radius than the ground state for comparable truncation bias. Solving \(l=0\) and \(l=1\) on a small common box can yield a spurious nonrelativistic 2s–2p splitting. Check separately that both energies tend to \(-1/4\) before interpreting a much smaller physical fine splitting. Subtracting independently computed energies amplifies absolute numerical biases even if each number appears visually close to its expected value.
The distinctive near-origin behaviour supplies a second check. Since \(\psi_{100}(0)\) is proportional to the slope of the reduced radial function at zero, a first forward difference \(u_1/h\) typically incurs a first-order error even when the energy error is second order. For the lattice shape above \(u_j\propto j q^j\), the first two positive grid values can be used to estimate the endpoint derivative by \((4u_1-u_2)/(2h)\). Test its convergence under the physical radial normalisation. For a contact perturbation, squaring an endpoint derivative doubles its small relative error to leading order. This is why an atomic calculation should include an observable-specific refinement criterion in addition to an energy tolerance.
Use an eigenvalue benchmark to separate numerical and physical shifts
A report on the infinite-grid hydrogenic ground state quotes energy \(-0.99750\) at \(h=0.10\) and attributes the difference from \(-1\) to a short-range interaction. Predict the lattice-only change on refinement to \(h=0.05\), and propose a test that could reveal a real interaction independently.
Derive and check the result
The lattice expression gives \(-2/[1+\sqrt{1.0025}]\simeq-0.999376\) at 0.05, so the discretisation alone accounts for the original difference at the stated accuracy. A local physical correction with fixed continuum strength should converge toward a fixed nonzero shift as \(h\to0\), while the lattice bias vanishes approximately as \(h^2/4\). Compute control and perturbed energies on exactly the same grids and compare their difference under refinement, with consistent treatment of the perturbation's physical range. An unresolved delta perturbation represented as a fixed diagonal value on one grid point changes its effective continuum strength upon refinement and would produce another artificial shift. Cross-check with the first-order expectation of a resolved physical potential or with the independently converged contact density.
Use an isotope pair to cancel a common transition-energy reference
High-precision spectroscopy often obtains its most reliable insight from combinations of frequencies rather than absolute energies. Consider two hydrogenic model isotopes with the same nuclear charge, different reduced masses \(\mu_1,\mu_2\) and different mean-square charge radii \(R_1^2,R_2^2\). For a specified transition the leading point-Coulomb frequency can be written \(C\mu\), since its \(n\)-dependent dimensionless numbers are fixed. A local nuclear-size perturbation shifts each participating \(s\) level by a factor proportional to \(|\psi_{ns}(0)|^2 R_i^2\propto\mu_i^3 R_i^2/n^3\), while a \(p\) level receives a much smaller finite-size correction in the same limit. The different powers of reduced mass and radial quantum number permit differences of transitions to cancel selected terms.
For illustration compare a 1s–2s optical frequency with a 1s–2p frequency within one model isotope, assuming the fine, radiative and differing upper-state structures have been independently accounted for in the desired order. Subtracting these frequencies cancels the entire common lower 1s energy and the gross equal 2s/2p Coulomb energy, leaving the upper 2s–2p differences. If instead one sought the large 1s contact contribution, subtracting these same two lines would remove precisely the effect of interest. An apparently convenient common reference can therefore eliminate physical signal as well as noise. Write the coefficient of each contributing level explicitly before selecting a frequency combination.
Suppose two independently fitted line frequencies \(\nu_a,\nu_b\) each have a 10 MHz common reference error and independent residual standard errors of 0.30 and 0.40 MHz. The covariance from the shared reference is \(100\,\mathrm{MHz}^2\). The difference has variance \(0.30^2+0.40^2=0.25\,\mathrm{MHz}^2\), hence 0.50 MHz standard error. Treating both total errors as independent instead would suggest roughly 14 MHz. Conversely, an error in a calibration scale proportional to frequency leaves a residual proportional to the frequency difference; its cancellation is only approximate. Reporting the provenance of uncertainties and their covariance can matter more than recording an extra digit of each absolute transition.
Recover a contact shift from two excited-state probes
In a diagnostic model a local perturbation gives an unknown positive 1s shift \(D\), an \(ns\) shift \(D/n^3\), and zero shifts of \(p\) levels. Relative to a matched reference, how do 1s–2s, 1s–2p and 1s–3s frequencies change? Which experimental difference removes the unknown common lower-state shift yet recovers \(D\)?
Derive and check the result
The changes are \((-7D/8)/h,\ -D/h,\ (-26D/27)/h\), respectively. Subtracting the 1s–2p shift from the 1s–2s shift gives \(D/(8h)\), since the common lower-state contribution cancels. For a measured difference of \(0.90\pm0.05\) MHz the implied \(D/h=7.2\pm0.4\) MHz. The 1s–3s shift should then be \(-6.93\) MHz in this stipulated model. If unavailable corrections also differ among the upper states, that value is not an absolute nuclear-radius extraction. The third line gives an independent test of the \(1/n^3\) contact scaling before attributing all measured differences to the single parameter \(D\).
Tutorial · measure degeneracy through independent calculations
Verify two inverse moments directly in the \(2p\) state
Use \(R_{21}(r)=r e^{-r/(2a)}/(2\sqrt6\,a^{5/2})\) and normalised \(Y_{1m}\). Evaluate \(\langle r^{-2}\rangle,\langle r^{-3}\rangle\) without parameter differentiation.
Work through the solution
The radial measure is \(r^2dr\), so after inserting \(R\) the general moment is \((24a^5)^{-1}\int_0^\infty r^{4-q}e^{-r/a}dr\) for \(r^{-q}\). For \(q=2\) the integral is \(2a^3\), giving \(1/(12a^2)\). For \(q=3\) it is \(a^2\), giving \(1/(24a^3)\). Both agree with the formulas for \(n=2,l=1\). Dropping the radial Jacobian would change both powers and could falsely suggest singular behaviour. The result is independent of \(m\) because the operator is rotationally scalar.
Calculate the complete \(n=2\) shifts in units of \(C_2\)
Resolve the kinetic, spin–orbit and Darwin contributions for \(2s_{1/2}\), \(2p_{1/2}\) and \(2p_{3/2}\). Which comparison isolates the effect of the spin–orbit term cleanly at this order?
Work through the solution
For \(s\), kinetic gives \(-[2-3/8]=-13/8\) and Darwin \(+1\), summing to \(-5/8\). For both \(p\) states the kinetic value is
The spin–orbit corrections are \(2/3-1=-1/3\) for \(j=1/2\) and \(2/3-1/2=1/6\) for \(j=3/2\), giving \(-5/8\) and \(-1/8\). Subtracting the two \(p\) levels removes their shared kinetic term and zero contact term. Their interval is \(C_2/2\). Comparing 2s with either \(p\) instead involves two different radial wavefunctions and does not isolate the same correction.
Separate a reduced-mass shift from fine structure
Consider two otherwise identical hydrogenic nuclei with \(M/m=1836\) and 3672. Predict the ratio of gross transition frequencies and compare its fractional change with the order of a fine-structure correction. Which common interpretation would conflate them?
Work through the solution
Gross transition frequencies scale as reduced mass \(\mu=m/(1+m/M)\). The heavier-to-lighter ratio is \((1+1/1836)/(1+1/3672)=1.000272\) approximately. The order of a relative fine-structure correction for \(Z=1\) is \(\alpha^2\simeq5.3\times10^{-5}\) with state-dependent coefficients. A change of isotope can shift a gross line by more than a particular resolved fine splitting, even with identical nuclear charge. Centroid measurements across isotopes and intervals within one multiplet are distinct observables. Recoil and nuclear magnetism require further inputs for precision predictions.
Further reading
Two electrons, exchange splitting and the cost of localisation
Quantum states, dynamics and measurement
Build a two-electron state that respects exchange, derive its charge and spin correlations, and then solve a two-site model exactly. The two examples reveal when a triplet is favoured and when an apparently weak hopping lowers the singlet instead.
Construct states before introducing a force
A two-electron wavefunction has two spatial arguments and two spin labels. The labels 1 and 2 identify argument slots; they do not attach persistent tags to individual identical electrons. Exchanging all position and spin variables must multiply an electronic state by minus one. This is the fermionic exchange postulate. It constrains which vectors describe electrons even when their Hamiltonian contains no spin-dependent term. A measurement with no access to the ordering of slots is represented by an observable symmetric under the same exchange.
Let \(a(\mathbf r),b(\mathbf r)\) be normalised orthogonal spatial orbitals. The symmetric and antisymmetric spatial combinations are \(\Phi_\pm=[a(1)b(2)\pm b(1)a(2)]/\sqrt2\). Combine \(\Phi_+\) with the spin singlet \((|\uparrow\downarrow\rangle-|\downarrow\uparrow\rangle)/\sqrt2\), and \(\Phi_-\) with any of the three symmetric triplet spin states. For equal positions the antisymmetric spatial combination vanishes exactly. Its joint probability has an exchange hole at coincidence even for noninteracting same-spin fermions. When \(a=b\), the antisymmetric combination vanishes identically and only the symmetric spatial state with opposite spins in a singlet is available. Occupation of the same spatial mode by two electrons is thus compatible with the exclusion principle if the full spin orbitals differ.
For two distinct orthogonal modes, both \(\Phi_+\) and \(\Phi_-\) have the same one-particle number density \(|a(\mathbf r)|^2+|b(\mathbf r)|^2\), normalised to two electrons. To see this, integrate \(|\Phi_\pm(\mathbf r_1,\mathbf r_2)|^2\) over \(\mathbf r_2\) and multiply by two. Cross terms contain \(\langle a|b\rangle=0\). Coincidence and correlation measurements can therefore distinguish preparations that share their entire one-particle density. The spin-antisymmetric singlet can also give correlated opposite spin outcomes along any common measurement axis, while both individual spins are unpolarised. Position and spin comparisons probe different reduced descriptions of the same total state.
Separate the direct and exchange integrals
For an independent-orbital estimate take \(H=h(1)+h(2)+v(1,2)\) with \(h a=\epsilon_a a,\ h b=\epsilon_b b\), and a symmetric spin-independent repulsion. Expand the expectation of \(v\) in \(\Phi_\pm\). Diagonal terms give the same direct integral and off-diagonal terms are conjugates:
For Coulomb repulsion \(K_{ab}\) is nonnegative: it is the positive Coulomb quadratic form of the transition density \(a^*b\), seen for instance from its Fourier representation weighted by \(4\pi/k^2\). Orthonormality only makes the spatial integral of the transition density vanish, not its weighted self-interaction. The expectation energies are \(\epsilon_a+\epsilon_b+J_{ab}\pm K_{ab}\). In this fixed pair of spatial orbitals the triplet is lower by \(2K_{ab}\). If the orbitals have disjoint support the exchange integral vanishes, although the direct repulsion need not. A splitting caused by spatial symmetry does not require an extra microscopic spin–spin repulsive force.
Set \(J_{ab}=0.80\) eV and \(K_{ab}=0.070\) eV in an illustrative excited configuration. Its Coulomb shifts are 0.87 eV and 0.73 eV. A weighted average over all four spin states is
Optical line strengths generally do not populate those four spin states equally. The energy difference is a statement about this restricted configuration; another spatial occupation can place a singlet below the entire triplet manifold. Predicting a ground-state spin therefore requires admitting the competing occupations and the one-body and correlation energies they carry.
Allow hopping and double occupation
Now take two orthonormal localised orbitals \(L,R\) of equal one-body energy. A fermion hops between them at amplitude \(-t\), and placing opposite spins on the same site costs \(U>0\). Define \(H=-t\sum_\sigma(c^\dagger_{L\sigma}c_{R\sigma}+c^\dagger_{R\sigma}c_{L\sigma})+U\sum_i n_{i\uparrow}n_{i\downarrow}\). This is a specified two-site Hubbard model, not a complete microscopic Coulomb Hamiltonian. Its direct intersite exchange integral is set to zero here, so its spin ordering need not follow the fixed-orbital calculation above. Position, spin and field units enter through the experimentally or computationally determined \(t,U\).
In the two-electron sector a state with two up spins must occupy one orbital on each site. Hopping would create two up spins in one orbital and therefore annihilates this state. Rotational symmetry implies the same energy zero for all three triplets. Define the singly occupied singlet \(|S\rangle\) and symmetric doubly occupied state \(|D_+\rangle=(|\uparrow\downarrow,0\rangle+|0,\uparrow\downarrow\rangle)/\sqrt2\). A consistent fermionic ordering gives an off-diagonal \(-2t\) between them; each direction and spin contributes and the normalisations leave the factor two. Changing the phase of \(D_+\) reverses that matrix element but leaves the eigenvalues unchanged. The orthogonal antisymmetric doublon remains at energy \(U\). The relevant singlet block is
The ground energy \(E_-<0\) for \(t\ne0\). At \(U\gg|t|\) expand the square root to obtain
The singlet–triplet splitting \(J_{\rm eff}=E_T-E_-\simeq4t^2/U\) can be represented in the singly occupied subspace by \(J_{\rm eff}(\mathbf S_L\cdot\mathbf S_R/\hbar^2-1/4)\). The singlet can lower its energy by virtual double occupation while spin symmetry blocks the triplets. The inferred spin coupling scales as the square of hopping and inversely with the energy cost. This mechanism is commonly called antiferromagnetic superexchange.
Determine a correlation without reading an eigenvector
The fraction of probability with double occupation in the ground state is \(\langle\partial H/\partial U\rangle\). Differentiating its energy gives
For positive large \(U\), \(D\simeq4t^2/U^2\). Comparing the derivative with the explicit eigenvector provides a useful independent test of signs and normalisations. From \(E s=-2t d\) one obtains
Normalising gives \(D=E^2/(4t^2+E^2)\), identical to the derivative expression for either lower-branch parameter value.
For \(t=10\) meV and \(U=100\) meV, \(\sqrt{U^2+16t^2}=107.70\) meV and the exact splitting is 3.85 meV. The leading 4.00 meV expression is about 3.9% high. Double occupation is only 3.58%, yet forbidding it at the outset would predict exactly zero splitting. A virtually occupied state can matter appreciably in a low-energy Hamiltonian even when a projective charge measurement rarely finds it occupied. At \(U=0\) the ground energy is \(-2|t|\), corresponding to two opposite spins in the bonding one-electron orbital; the double-occupation fraction is one half. The large-\(U\) expression diverges as \(U\to0\) because its perturbative premise disappears. The exact two-state matrix remains finite.
Derive an effective screening charge for a helium-like ground state
A two-electron atom provides a continuous-space counterpart to the two-site model. In atomic units set \(\hbar=m_e=e^2/(4\pi\epsilon_0)=1\) and take an infinitely heavy nucleus of charge \(Z\). The nonrelativistic Hamiltonian is
The two one-electron ground orbitals may be identical in space because opposite spins can form an antisymmetric singlet. Use a trial product of two normalised hydrogenic functions \(u_\zeta(\mathbf r)=(\zeta^3/\pi)^{1/2}e^{-\zeta r}\) with a variable positive exponent \(\zeta\). This single parameter lets the spatial cloud expand in response to mutual repulsion. Choosing the exponent equal to \(Z\) without testing it would impose the noninteracting size on an interacting problem.
A single orbital gives \(\langle-\nabla^2/2\rangle=\zeta^2/2\) and \(\langle1/r\rangle=\zeta\), either by direct integration or by hydrogenic scaling. Two electrons thus contribute \(\zeta^2-2Z\zeta\) to the expectation. To derive the repulsion term, average \(1/|\mathbf r_1-\mathbf r_2|\) over two independent uniform angles at fixed radii. Gauss's shell result, or a direct change of variable in the angular integral, gives \(1/\max(r_1,r_2)\). The radial probability is
Symmetry between the two electron labels permits restricting one integral to \(r_2<r_1\), then doubling:
The first part of the resulting \(r\) integral gives \(2\zeta\). The three exponential subtraction terms sum to \(11\zeta/8\), leaving \(J=5\zeta/8\). Their evaluation uses \(\int_0^\infty r^ne^{-a r}dr=n!/a^{n+1}\). Both the dependence linear in \(\zeta\) and the positive sign follow from scaling an inverse-distance repulsion; only the numerical coefficient needed the angular and radial integration. Replacing the expectation of \(1/r_{12}\) by \(1/\langle r_{12}\rangle\) would generally give a different coefficient because inverse distance is nonlinear.
Consequently \(E(\zeta)=\zeta^2-2(Z-5/16)\zeta\) is an upper bound on the ground energy. It minimises at \(\zeta_*=Z-5/16\), with \(E_{\rm var}=-(Z-5/16)^2\) hartree for positive \(\zeta_*\). For helium \(Z=2\), \(\zeta_*=1.6875\), giving \(-2.84766\) hartree, compared with \(-2.75\) hartree at \(\zeta=2\). The one-electron ion has energy \(-2\) hartree, so this variational value lies below the threshold for an electron plus the ion and demonstrates binding within the model. The trial ionisation energy \(0.84766\) hartree is a lower bound on the exact ionisation energy when that threshold is known exactly. An upper bound on the neutral energy gives a lower bound on the energy required to remove an electron.
The interpretation of \(5/16\) as a screening correction is limited. At short radii each electron feels nearly the full nuclear singularity, while far outside it sees the remaining net charge. One constant exponent cannot reproduce both limits and cannot describe how the two electron positions avoid one another at fixed one-particle radius. The product trial permits nonzero joint weight at electron coincidence. Multiplying by a factor involving \(r_{12}\) introduces genuine correlation beyond independent orbitals. Optimising a broader variational family containing this product can only lower or retain the variational energy, provided its integrals and normalisation are computed consistently. Monitoring energy together with the pair-separation distribution tests whether the enlargement captures the physics of repulsion rather than merely adjusting a one-body radius.
Infer a local two-electron boundary condition from the Coulomb singularity
Near coincidence of two unlike-spin electrons, the Coulomb repulsion diverges like \(1/r_{12}\). The wavefunction itself can remain finite at coincidence, but its derivative must cancel this singularity in the Schrödinger equation. Consider a fixed smooth centre coordinate and average the wavefunction over the direction of the interelectron separation \(r\), away from simultaneous nuclear coincidence. Assume an expansion \(\bar\Psi(r)=A+Br+\cdots\). In atomic units the reduced mass is one half, so the relative spherical kinetic operator is \(-[d^2/dr^2+(2/r)d/dr]\) for the locally \(s\)-wave part. Its leading singular term is \(-2B/r\). Adding \(\bar\Psi/r\) gives coefficient \(A-2B\) of \(1/r\). A finite energy eigenvalue requires this coefficient to vanish:
The positive cusp slope means the spatial amplitude rises as the electrons move apart from contact, consistent with repulsion. The corresponding electron–nucleus cusp has opposite sign and coefficient set by the nuclear charge and reduced mass. In a same-spin state the scalar contact amplitude vanishes by antisymmetry; this \(s\)-wave formula becomes \(0=0\) and a leading higher-partial-wave analysis is needed. Forgetting either angular averaging or exchange symmetry can turn an instructive local condition into a false statement about every directional derivative of every wavefunction.
A product of independent \(1s\) orbitals is smooth in \(r_{12}\) at a generic fixed centre and has no required linear cusp in the spherical average. A trial factor \(1+r_{12}/2\) in atomic units can impose the first-order unlike-spin cusp while leaving additional variational freedom to model long-range behaviour. Merely enforcing the cusp does not solve the entire two-electron problem. It constrains a local ratio of derivative to value, while energy depends on a six-dimensional integral. In variational Monte Carlo one can diagnose this distinction through the local energy \(H\Psi/\Psi\) near coincidence. A cusp-mismatched trial may have a singular local energy even though the volume element \(r^2dr\) keeps its integrated average finite. Imposing the cusp can reduce variance and improve short-distance pair observables more dramatically than it changes the energy expectation.
Use one-body occupation measurements to detect missing correlations
A single determinant of orthonormal spin orbitals \(\chi_i\) has a one-particle reduced density matrix \(\gamma=\sum_{\rm occupied}|\chi_i\rangle\langle\chi_i|\), normalised to the electron number \(N_e\). Thus \(\gamma^2=\gamma\) and its eigenvalues are zero or one. This is an algebraic signature of a single pure Slater determinant in the spin-orbital convention. For a correlated pure fermion state, natural occupations can become fractional while remaining between zero and one and summing to \(N_e\). Ensemble mixing can produce fractional occupations too, so knowing whether the entire state is pure matters if one wants to interpret fractional one-particle populations as evidence of correlation.
Consider the normalised two-electron singlet \(|\Psi\rangle=\sqrt{0.8}\,|a\uparrow,a\downarrow\rangle+\sqrt{0.2}\,|b\uparrow,b\downarrow\rangle\), with each ket a determinant. A one-body operator changes at most one occupied spin orbital, so its matrix element between these two doubly different determinants vanishes. The four natural spin-orbital occupations are \(0.8,0.8,0.2,0.2\). Their sum is two while \(\operatorname{tr}\gamma^2=1.36\), smaller than the determinant value two. An incoherent mixture of the two determinants at the same weights has the same one-body matrix, although it no longer has their joint coherence. A two-body pair-transfer operator that converts both \(a\) electrons into \(b\) electrons, plus its adjoint, can reveal a relative phase between these branches. Thus a complete one-body spectrum still need not determine a two-body state.
The symmetric Hubbard dimer ground state has another direct relation between energy derivatives and its one-body coherence. Let \(T=\sum_\sigma(c^\dagger_{L\sigma}c_{R\sigma}+c^\dagger_{R\sigma}c_{L\sigma})\). The energy derivative gives
At \(U=0\) and \(t>0\), \(\langle T\rangle=2\) because both electrons occupy the bonding orbital. At large \(U/t\) this coherence approaches zero even though the exact finite-\(t\) ground state remains a total spin singlet. In the bonding/antibonding spatial basis, the sum of both populations is two and their difference is \(\langle T\rangle\). For the example \(U=100,\ t=10\) meV this gives spatial occupations roughly 1.371 and 0.629. Dividing by two gives the spin-orbital occupations for each spin in this singlet. Site populations alone are one on each site by symmetry at every \(U/t\); their apparent constancy completely misses this changing form of correlation.
Break site symmetry and measure the onset of charge transfer
Add a static site-energy imbalance with energies \(-\Delta/2\) on \(L\) and \(+\Delta/2\) on \(R\). The singly occupied configuration still has total site energy zero, while double occupations cost \(U-\Delta\) and \(U+\Delta\). For \(|t|\ll U-|\Delta|\) the singly occupied singlet gains the second-order shift \(-2t^2/(U-\Delta)-2t^2/(U+\Delta)\), since its matrix element to either double occupation has magnitude \(\sqrt2|t|\). The triplets remain blocked. The effective exchange splitting is \(4t^2U/(U^2-\Delta^2)\). At zero imbalance it reduces to the earlier \(4t^2/U\); small imbalance changes it quadratically, consistent with exchanging left and right sites.
For \(U=100,\ t=5,\ \Delta=40\) meV, the estimate gives \(1.19\) meV compared with \(1.00\) meV at zero bias. Increasing imbalance can make one virtual double occupation especially inexpensive, changing the gap before the mean site charge substantially relocates. Near \(\Delta=U\) the denominator vanishes and the perturbative model predicts a divergence. The true three-state singlet matrix instead has an avoided crossing of singly and doubly occupied configurations. A sweep through that region should retain both double occupations and compute site charge from \(-2\,\partial E/\partial\Delta\), with the sign matched to the specified imbalance. Here an apparent runaway effective spin coupling marks the failure of eliminating charge degrees of freedom, rather than an arbitrarily large spin energy in the actual finite Hamiltonian.
Measure singlet–triplet exchange without a spin force
Change the on-site repulsion in a two-electron dimer. Check whether exchange inferred from the spectrum follows the virtual-hopping estimate.
See exchange interference directly in a two-port experiment
A lossless balanced beam splitter for two orthonormal single-particle modes can be chosen to act on creation operators as \(a^\dagger\to(c^\dagger+d^\dagger)/\sqrt2,\ b^\dagger\to(c^\dagger-d^\dagger)/\sqrt2\). Bring two identical particles to the device, one per input, with wave-packet timing and internal states controlled. The input \(a^\dagger b^\dagger|0\rangle\) contains no explicit interaction. Nevertheless the coincidence statistics after the device depend on exchange because two paths can lead to the same unordered output configuration. This provides a way to test exchange far from the Coulomb energy calculations of the previous sections.
For identical spinless bosons multiply the two sums and use commuting creation operators. The cross terms cancel, leaving \([(c^\dagger)^2-(d^\dagger)^2]|0\rangle/2=(|2,0\rangle-|0,2\rangle)/\sqrt2\). Both particles leave the same port and coincidence probability vanishes. The \(\sqrt2\) in a normalised doubly occupied Fock state is essential. For identical fermions in the same internal state the repeated creation terms vanish and the cross terms add because \(d^\dagger c^\dagger=-c^\dagger d^\dagger\). The outgoing state has one particle in each port with unit probability. Neither result requires an attractive or repulsive force at the splitter. Their interpretation turns on whether the alternatives remain indistinguishable and on the symmetry of the total input.
Now give the two particles internal wave packets \(|u\rangle,|v\rangle\), which may encode time, frequency or spin, and suppose the detectors report output ports but do not resolve internal labels. One coincidence alternative puts \(u\) in \(c\) and \(v\) in \(d\); the other interchanges them. The interference cross term contains the product \(\langle u|v\rangle\langle v|u\rangle=|\langle u|v\rangle|^2\). At a balanced splitter the coincidence probability is \([1-|\langle u|v\rangle|^2]/2\) for initially independently prepared bosons and \([1+|\langle u|v\rangle|^2]/2\) for corresponding fermions. At zero overlap both reduce to one half, as expected for two distinguishable independent particles each taking a random output.
Take transform-limited Gaussian wavepacket intensities of common time variance \(\sigma_t^2\) with delay \(\tau\) between their centres and no carrier mismatch. Integrating their two normalised amplitude envelopes gives
For \(\sigma_t=0.50\) ps and delay 1.00 ps this is
The predicted bosonic coincidence fraction is 0.316 and the fermionic value 0.684. A narrow time gate can itself identify the particles differently at different delays and must be included in the counting model. Measuring the single-output rates together with coincidences tests splitter balance and detection bias before converting dip or peak contrast into an overlap estimate.
Infer distinguishability with an unbalanced splitter
A calibrated splitter has intensity transmittance \(T=0.60\), reflectance \(R=0.40\) and negligible loss. Two photons from separate inputs give coincidence probability 0.184 at equal central arrival time. Infer their internal squared overlap. Would equal-time arrival alone have guaranteed perfect bunching?
Derive and check the result
For indistinguishable paths the two coincidence amplitudes have opposite signs with magnitudes \(T,R\). A nonresolving detector gives
Substitution yields squared overlap \((0.52-0.184)/0.48=0.70\). Even perfect internal overlap at this unbalanced splitter would leave \((T-R)^2=0.040\) coincidences. Equal arrival time controls only one possible distinguishing label; orthogonal polarisation or spectral mismatch can still reduce overlap. A far-delay reference should give \(T^2+R^2=0.52\) for distinguishable, otherwise comparable photons. This independent control helps separate exchange interference from lost counts or a miscalibrated splitter.
Tutorial · discriminate spatial exchange from virtual hopping
Normalise two nonorthogonal orbitals before predicting coincidences
Let \(a,b\) each have norm one but overlap \(s=0.30\). Find the normalisations of their symmetric and antisymmetric products. Does the antisymmetric state still vanish at common position?
Work through the solution
The inner product \(\langle ab|ba\rangle=|s|^2=0.09\). The normalisation denominators are
At identical positions the antisymmetric numerator cancels pointwise for every \(s\). When the orbitals become identical its norm tends to zero and there is no independent antisymmetric state of that pair. For nonzero overlap the one-body cross terms in the earlier density calculation no longer integrate away, so those equal-density formulas must be rederived. Orthonormalising local orbitals changes the parameters of a corresponding Hubbard model as well.
Infer a hopping amplitude from a measured singlet gap
A calibrated two-site sample has \(U=120\) meV and a singlet–triplet gap 5.0 meV. In the model above find \(t\) exactly, predict the double-occupation probability and compare with a large-\(U\) inference.
Work through the solution
Writing \(J=(\sqrt{U^2+16t^2}-U)/2\) gives \(4t^2=J(U+J)\), hence \(|t|=12.50\) meV. The large-\(U\) estimate \(\sqrt{JU}/2=12.25\) meV is close but measurably different. The double-occupation fraction is
Gap alone cannot distinguish signs of \(t\) in a two-site model because rephasing one orbital reverses the sign. Measuring charge fluctuations independently tests whether the observed spin gap can be explained by this same virtual process.
Predict coherent double-occupation oscillations
Start suddenly in the singly occupied singlet of the symmetric two-site model. Find the probability of observing either doubly occupied site after time \(\tau\) and its maximum at \(U=100,\ t=10\) meV. Predict the triplet control.
Work through the solution
Subtract \(U/2\) times identity from the two-dimensional Hamiltonian. The traceless matrix squares to \((U^2+16t^2)I/4\). Exponentiating gives
Its maximum is
This is larger than the ground-state admixture because the sudden preparation is a coherent superposition of both energy eigenstates. A triplet evolves with no doubly occupied component in this ideal Hamiltonian. Observing double occupation after triplet preparation would test spin mixing, state-preparation fidelity or additional orbitals.
Further reading
Measure tunnelling from a four-site spectrum
Computational quantum experiments
Four localised orbitals form a minimal double well. Raise the inner two site energies and ask why two states concentrated in the outer wells still acquire different energies. Measure the splitting in the spectrum, predict an oscillation in time and reproduce the levels independently with OneSimulation.
Construct an operator before drawing an energy diagram
Label the sites \(1,2,3,4\) in order. The end orbitals have on-site energy zero, the middle two have energy \(V>0\) and every neighbouring pair has real hopping matrix element \(-t\) with \(t>0\). The four occupation states form an orthonormal basis for one particle. Equal diagonal energies of the ends do not make their symmetric and antisymmetric combinations degenerate when there is a virtual path through the interior. There are no direct links between sites one and three or one and four. Keeping track of every allowed step will fix the power of \(t\) in the final answer.
Reflection maps \(1\leftrightarrow4\) and \(2\leftrightarrow3\), and commutes with \(H\). In each parity sector use the normalised outer and inner basis vectors \((|1\rangle\pm|4\rangle)/\sqrt2\) and \((|2\rangle\pm|3\rangle)/\sqrt2\). The diagonal outer element vanishes in both sectors; the hopping inside the middle pair shifts its even and odd energies to \(D_e=V-t\) and \(D_o=V+t\). The outer–inner matrix element remains \(-t\). This reduces the four-dimensional problem to two symmetric two-by-two matrices without neglecting any state.
Eliminate the barrier amplitudes and estimate the splitting
In a sector with interior energy \(D\), the secular equation is
The lower root is \(E_-(D)=[D-\sqrt{D^2+4t^2}]/2\), or the numerically better \(-2t^2/(D+\sqrt{D^2+4t^2})\). For \(D\gg t\) the shift is approximately \(-t^2/D\). It is more negative for the even state because \(D_e<D_o\). Subtract the two shifts before approximating their difference.
A single outward excursion produces an order-\(t^2/V\) shift in both end states. Only a three-hop path connects the different ends, so their splitting is smaller. Measuring an overall displacement of two spectral lines and measuring the distance between them test different physical mechanisms.
Predict a time trace and define what is measured
Denote the two low-energy eigenstates by \(|e\rangle,|o\rangle\). Prepare \((|e\rangle+|o\rangle)/\sqrt2\). In the corresponding opposite superposition \((|e\rangle-|o\rangle)/\sqrt2\), the occupation at time \(\tau\) equals \(\sin^2(\Delta E\,\tau/2\hbar)\). Its first maximum is at \(\pi\hbar/\Delta E\). These superpositions include interior weight, especially at low barrier. A detector on site four alone measures a different projector. Preparing bare site one excites both high and low doublets and can generate additional fast oscillations.
For \(V/t=4\), the two lower eigenvalues in units of \(t\) are \((3-\sqrt{13})/2\) and \((5-\sqrt{29})/2\), about −0.30278 and −0.19258. Their separation is about \(0.11019t\). The high-barrier approximation gives \(0.125t\). With \(t=1\,\mathrm{meV}\), \(\hbar=0.65821\,\mathrm{meV\,ps}\) and the first complete transfer in the dressed basis takes about 18.8 ps. If a measurement integrates over many such oscillations, it may return one half despite perfectly coherent evolution.
Compare spectra from three independent constructions
Use the parameter controls to vary the middle barrier and hopping. The plot shows the exact splitting and its leading virtual-hopping prediction over a range of \(V/t\). The printed result gives an actual transfer time. The downloadable OneSimulation model builds the original four-site Hamiltonian and solves its eigenvalue problem by contour integration. Compare all four eigenvalues with the two parity blocks before interpreting their small difference. A wrong sign on one edge of this open chain can be removed by a local change of basis and may leave its spectrum unchanged, so also check any phase-sensitive observable used for preparation.
Keep the hopping fixed at 1 meV and compare two barriers. Start with a 4 meV barrier and raise it to 8 meV. Record both splittings and estimate the change in the first transfer time before reading off the prediction.
Tutorial
Hold \(V\) fixed and halve \(t\) in the high-barrier limit. How do the common shift, splitting and transfer time change?
Work through the solution
The leading common shift scales as \(t^2/V\) and falls by four. The splitting scales as \(t^3/V^2\) and falls by eight. The transfer time grows eightfold. Halving both \(V\) and \(t\) instead keeps their ratio fixed and halves every eigenvalue.
Explain why a small static asymmetry between the end wells can suppress almost complete transfer while increasing their measured frequency splitting.
Work through the solution
In a two-state reduction, detuning \(\delta\) and coupling \(J\) give separation \(\sqrt{\delta^2+4J^2}\). Starting in one localised state, the maximum transfer probability is \(4J^2/(\delta^2+4J^2)\). Both the frequency and the contrast are needed to infer the coupling.
How could one check that a contour solver has found both members of a closely spaced doublet rather than printing one twice?
Work through the solution
Check the rank of the independent projected vectors and the residual norm for each vector. Then exploit reflection parity or solve in each symmetry sector independently. Repeating a low residual for two nearly parallel vectors does not establish a two-dimensional eigenspace.
The continuous barrier calculation provides a different model in which barrier width eventually produces an exponential dependence.