An electric field competes with entropy of mixing
Take a bulk reservoir containing mobile ions with charges \(+e,-e\), each at number density \(n_b\). The solvent is a uniform continuum of permittivity \(\epsilon\), the bath holds absolute temperature \(T\), and no reactions or Faradaic currents occur at the wall. At thermal equilibrium the electrochemical potential of each species is spatially constant. For an ideal dilute gas of particles it contains \(k_BT\ln(n_\pm/n_b)\) from mixing plus electrostatic energy \(\pm eV\). Set the bulk potential to zero. Equating the local and bulk electrochemical potentials yields
At positive \(V\) the negative counterions concentrate and the positive coions are depleted. Total mobile charge is
Substituting into Poisson's equation and defining dimensionless \(\psi=eV/(k_BT)\) gives
The parameter \(n_b\) is a density of one species, not both together. For a 1:1 salt specified in mol/litre convert to formula units per cubic metre using \(1000N_A\) before substitution. For a mixture the linear screening coefficient generalises to \(e^2\sum_i z_i^2n_i/(\epsilon k_BT)\), whereas the full nonlinear right-hand side remains a sum of exponentials. An externally maintained reservoir fixes chemical potentials; a sealed very small cell can instead require separate number conservation for every species.
What the small-potential limit predicts and what it neglects
For \(|\psi|\ll1\), replace \(\sinh\psi\) by \(\psi\). Above a planar wall at \(z=0\) with prescribed potential \(V_s\) and \(V\to0\) far away, the bounded solution is
With the normal into liquid \(+\hat{\mathbf z}\), the wall displacement is
For a conducting wall with no interior field this equals its free surface charge. Therefore \(C_{\rm diff}/A=d\sigma/dV_s=\epsilon\kappa\), dimensionally a dielectric layer of thickness \(\kappa^{-1}\). The ionic concentration actually varies continuously; it is not a plate of opposite charge located at that distance.
Integrating charge density \(-\epsilon\kappa^2V(z)\) over \(z>0\) gives
The screening cloud and wall together are neutral per area. The fraction of compensating charge within distance \(h\) is \(1-e^{-\kappa h}\). At one screening length the potential has fallen to \(1/e\) and \(63.2\%\) of the countercharge has accumulated. For a spherical bead curvature changes this simple relationship between potential ratio and enclosed charge. The ionic constitutive relation is the same, but the spatial Laplacian and collecting area differ.
With \(\epsilon_r=78.5,\ T=298\) K and \(1.00\) mM of a fully dissociated symmetric monovalent salt, \(n_b\simeq6.02\times10^{23}\) m⁻³ and \(\kappa^{-1}\simeq9.62\) nm. The linear diffuse capacitance is about \(0.072\) F/m². Increasing concentration fourfold halves the screening length and doubles this capacitance at fixed solvent response. Close to molecular length scales the continuum assumptions and concentration-independent permittivity become progressively questionable, so the square-root law should be tested in the intended concentration range.
Background · How small is a small electrostatic potential?
In a symmetric electrolyte the mean charge term is proportional to \(\sinh u\), with \(u=ze\psi/(k_BT)\) measured relative to the neutral reservoir. A potential being small in volts gives no absolute criterion: the valence and temperature set the relevant scale. Taylor expansion yields the fractional error in replacing the ionic source by its linearised value,
For roughly 1% local source accuracy this estimate asks for \(|u|\lesssim0.245\). At 298 K it gives about 6.3 mV for monovalent ions and 3.1 mV for divalent ions. This is a criterion on the local differential equation. An integrated charge or differential capacitance can have a different relative error and merits its own check.
Solve the nonlinear planar boundary problem
With planar symmetry \(\psi''=\kappa^2\sinh\psi\). Multiply both sides by \(\psi'\) and integrate from the remote bulk where \(\psi,\psi'\to0\). This gives
Choose the branch \(\psi'=-2\kappa\sinh(\psi/2)\), which decays to zero for either sign of surface potential. The identity \(d\ln|\tanh(\psi/4)|/d\psi=[2\sinh(\psi/2)]^{-1}\) turns the separated equation into
The physical potential itself is not a simple exponential at finite bias. Its distant tail has the same decay length but extrapolates back to a different amplitude \(4\tanh(\psi_s/4)\) in dimensionless units. A far-field slope can therefore recover \(\kappa\), while a linear extrapolation of its intercept underestimates large surface potentials. The nonlinear solution reduces continuously to the linear one because \(\tanh x\sim x\).
At \(z=0\), using \(D_z=-\epsilon k_BT\psi'/e\) gives
The first relation is odd in surface voltage and the differential capacitance is even for this symmetric salt model. Increasing voltage concentrates counterions and allows more charge per further voltage increment. For \(V_s=50\) mV at 298 K, \(V_s/(2k_BT/e)\simeq0.973\). The differential capacitance is about \(1.51\) times its zero-bias value, while the secant ratio \(\sigma/V_s\) is only about \(1.17\) times that value. A small AC perturbation superposed slowly about a DC bias measures the differential slope if ionic transport remains equilibrated.
An independent mechanical check of the nonlinear field
The ideal mobile ions have an osmotic pressure excess relative to the reservoir \(\Delta p=k_BT(n_++n_--2n_b)=2n_bk_BT(\cosh\psi-1)\). From the first integral the electrical normal stress magnitude \(\epsilon E^2/2\) equals this excess. Thus \(\Delta p-\epsilon E^2/2\) is spatially constant and vanishes in the bulk of the isolated-wall problem. One can derive the same result by differentiating the pressure: \(d\Delta p/dz=\rho E\) at equilibrium. The cancellation provides a sensitive joint test of the ion distribution and the potential gradient.
Confine electrolyte between two equal positively biased parallel walls instead. By symmetry \(E=0\) at the midplane but \(\psi_m\) generally remains positive. The constant excess normal pressure is then \(2n_bk_BT(\cosh\psi_m-1)>0\). Overlap of the diffuse layers produces a repulsive osmotic force per area in this mean-field model. With large separation the midplane potential tends to zero and so does that force. A solution built by naively superposing two high-voltage nonlinear wall profiles will generally violate the constant-pressure test.
Separate a near-wall compact layer from the diffuse response
A finite exclusion distance for ion centres near a real electrode can be modelled at first by a compact dielectric layer of capacitance per area \(c_s\). Its voltage drop is \(\sigma/c_s\); the diffuse layer starts at potential \(V_d\). For applied bias measured relative to the bulk and a chosen neutral reference,
Differentiate with respect to surface charge:
The diffuse constitutive relation must use \(V_d\), not the entire applied voltage. For \(c_s=0.20\) F/m² and low-bias \(c_d=0.072\) F/m², the measured capacitance is about 0.053 F/m². Even as \(c_d\) grows, this simple series model cannot exceed \(c_s\). It offers a physically distinct explanation for a measured saturation, alongside finite ion size, adsorption, dielectric variation and other model extensions. A static capacitance measurement alone cannot uniquely distinguish all of them.
Use layer overlap to infer a mechanical force independently of capacitance
Consider identical parallel electrodes at \(z=\pm H\), held at the same small positive potential \(V_s\) relative to a salt reservoir in chemical equilibrium with the gap. Neither electrode is an ordinary reference for the other: a voltage meter connected only between them reads zero while each diffuse layer experiences a nonzero potential relative to the reservoir. Under the linear screening approximation the potential obeys \(V''=\kappa^2V\). Reflection symmetry enforces \(V'(0)=0\). Matching both wall potentials gives \(V(z)=V_s\cosh(\kappa z)/\cosh(\kappa H)\), so the midplane voltage is
The magnitude of free charge per area on each inner electrode face is \(\epsilon\kappa V_s\tanh(\kappa H)\). At large \(H\) each plate recovers its isolated-wall charge. At small \(H\) the whole gap is nearly at \(V_s\), so very little normal field is required to maintain it and each facing surface carries less charge. This behaviour differs from two oppositely biased plates, whose nearly uniform internal field grows as their separation decreases. The reservoir reference and voltage symmetry decide which experiment is being performed.
To leading nonzero order in \(V_s\), the osmotic excess force per area between these identical walls can be found at the field-free midplane. There it is \(2n_bk_BT(\cosh\psi_m-1)\simeq n_b k_BT\psi_m^2=\epsilon\kappa^2V_s^2/[2\cosh^2(\kappa H)]\). Why use a term quadratic in \(V_s\) when the potential was found linearly? The pressure's zeroth-order excess vanishes and the first-order ionic density changes cancel between opposite species. Its first measurable correction is quadratic. The cubic error in the linear potential changes the computed pressure only at fourth order in \(V_s\), making the mixed expansion consistent.
For \(\kappa^{-1}=10\) nm, \(\epsilon=78.5\epsilon_0\) and \(V_s=5.0\) mV, at half-gap \(H=10\) nm the predicted repulsive pressure is about 36.5 Pa. At \(H=20\) nm it drops to roughly 6.14 Pa. The potential rose by only a few millivolts yet its ionic osmotic consequence extends across the entire overlap region. As \(H\) becomes large, \(\cosh^{-2}(\kappa H)\simeq4e^{-2\kappa H}\), giving exponential decay with the full separation \(2H\). This is a force measurement of the same screening scale measured independently by a voltage probe. Surface roughness, salt exclusion and adsorption can influence a real nanometre-scale force curve and should be distinguished from deviations in the bulk screening length.
If the electrode charges rather than their potentials are fixed, the wall derivative is prescribed. The even solution then has \(V_m=\sigma/[\epsilon\kappa\sinh(\kappa H)]\) in the linear regime, and pressure \(\sigma^2/[2\epsilon\sinh^2(\kappa H)]\). As \(H\) shrinks the linear approximation will eventually fail for fixed nonzero \(\sigma\), because \(V_m\) grows. Comparing the constant-potential and constant-charge formulas without adjusting their boundary conditions could suggest contradictory predictions where each applies to a different experiment.
Estimate how quickly the ion cloud can follow a capacitance measurement
Static Poisson–Boltzmann theory assumes ions are in equilibrium at each measured voltage. A time-dependent measurement can test that assumption. For dilute symmetric monovalent ions with equal diffusivity \(D_i\), small density perturbations obey the linearised number fluxes \(\mathbf j_\pm=-D_i[\nabla\delta n_\pm\pm e n_b\nabla V/(k_BT)]\), combining diffusion with electric drift. Assume no bulk reactions. Subtract the two continuity equations and multiply by \(e\), yielding a charge-current density \(\mathbf J=-D_i[\nabla\rho+2 e^2 n_b\nabla V/(k_BT)]\). Use \(\nabla^2V=-\rho/\epsilon\) in the bulk to obtain
A spatial harmonic of wavenumber \(k\) decays at rate \(D_i(k^2+\kappa^2)\) in the unbounded linear bulk model. The long-wavelength Debye charge-relaxation time is \(\tau_D=1/(D_i\kappa^2)\), also recovered by dividing permittivity by the dilute ionic conductivity \(\sigma_{\rm ion}=2 e^2n_bD_i/(k_BT)\). The total salt-density perturbation instead obeys ordinary diffusion because the leading positive and negative drift terms cancel. Fast local charge relaxation and slower redistribution of neutral salt are different observables.
For \(D_i=1.0\times10^{-9}\) m²/s and \(\kappa^{-1}=10\) nm, this local time is 100 ns, corresponding to an angular rollover scale \(1/\tau_D=10^7\) s⁻¹ or ordinary frequency about 1.6 MHz. Blocking electrodes in a cell of thickness \(L\gg\kappa^{-1}\) can display a slower charging time. Estimate its series resistance \(R=L/(\sigma_{\rm ion}A)\) and diffuse capacitance \(C\sim\epsilon\kappa A\) for one interface. Their product is of order \(L/(D_i\kappa)\). For \(L=100\) μm with the preceding parameters this is about 1 ms, orders of magnitude above the local bulk time. Two identical interfaces in series supply an extra numerical factor; finite reservoirs and unequal mobilities can introduce further scales.
A low-frequency impedance experiment interpreted as the equilibrium \(d\sigma/dV\) must therefore allow the actual circuit and cell to charge, not merely wait several local Debye times. Varying cell spacing helps distinguish a geometry-dependent charging time from an intrinsic screening-length change. This diffusion calculation and the static pressure calculation share the same \(\kappa\), giving independent checks on a physical fit to voltage, force and time-resolved measurements.
Check reservoir and continuum assumptions using actual particle numbers
The grand-canonical ion profiles implicitly allow the diffuse layers to draw particles from a large reservoir without changing the reservoir's chemical potentials. Whether this is reasonable can be checked with a dimensioned inventory. For a 1 mM monovalent salt, each species has about \(6.02\times10^{23}\) particles per cubic metre. A cell of area \(1\) mm² and depth \(100\) μm therefore starts with \(6.02\times10^{13}\) ions of each species. A surface charge density of \(1.0\) mC/m² on one plate amounts to \(6.24\times10^9\) elementary charges on that area. Even a conservative estimate in which each net countercharge requires one ion from the bulk uses only about \(10^{-4}\) of the available counterions.
Keep the same area and salt concentration but reduce the gap to 20 nm. Now only \(1.20\times10^{10}\) ions of each species occupy the cell initially. The same surface charge is comparable with half the inventory of one species. The remote-neutral-reservoir approximation is no longer automatically credible, especially if both walls attract counterions of the same sign. One must specify how ions and compensating charge can enter or leave, what the electrodes' chemical or electrical preparations enforce, and how much fluid actually belongs to the reservoir. An applied electrostatic boundary voltage fixes no ionic chemical potential by itself.
For a sealed cell write the equilibrium densities instead as \(n_\pm(z)=A_\pm \exp[\mp eV(z)/(k_BT)]\). The constants \(A_\pm\) must be chosen so that integrals of \(n_\pm\) over the physical volume equal the known numbers of each species. Substitution into Poisson's equation gives a coupled boundary problem with two additional global constraints. Adding a constant to \(V\) and appropriately rescaling \(A_\pm\) leaves the densities unchanged; electrical reference and chemical normalisation must be chosen consistently. A calculation holding both fixed bulk densities and exact sealed inventories can be overconstrained if diffuse layers hold appreciable salt.
The continuum approximation also makes a statement about scale. A cube of side one screening length near 10 nm at 1 mM holds roughly \(0.60\) ions of either species on average. This does not by itself invalidate a mean density for a large planar electrode, which averages over many lateral regions and thermal configurations. It does warn against interpreting the smooth one-dimensional density as a snapshot of a single nanometre-sized volume with a deterministic fractional particle. Force or voltage measurements with different lateral averaging areas can show quite different fluctuations even when their mean profiles follow the same equation.
As another self-check compare the predicted contact concentration with available molecular packing. The ideal theory gives
Starting from 1 mM, a surface potential near \(0.25\) V at 298 K would multiply concentration by roughly \(1.7\times10^4\), corresponding to tens of molar even before allowing room for solvent. A molecular model or a measured finite-size constitutive relation is then more appropriate for quantitative contact density. The failure is in extrapolating the dilute ideal entropy, not in Gauss's law or the electrostatic boundary condition. Source, solvent, reservoir and detector scales determine where the otherwise elegant analytic solution becomes an approximation to test.
Resolve a screening length
Compare the linear screened profile with a grid solution as the ratio of thickness to screening length grows. Separate failure to resolve the layer from failure of the linear material law.
How many excess ions, not just how much net charge?
Count the salt adsorbed in a planar diffuse layer
The total countercharge per area equals the negative surface charge. Separately calculate the excess number of ions of both signs over the neutral bulk value for a symmetric electrolyte at prescribed surface potential. Which quantity changes sign if the wall voltage reverses?
Derive and check the result
Define \(\Gamma=\int_0^\infty[n_+(z)+n_-(z)-2n_b]\,dz=2n_b\int_0^\infty(\cosh\psi-1)dz\). The integrand is nonnegative for either sign of wall voltage. For \(\psi_s>0\), substitute \(dz=-d\psi/[2\kappa\sinh(\psi/2)]\) from the first integral. Then \(\cosh\psi-1=2\sinh^2(\psi/2)\) makes the resulting integral elementary. The result, also valid at negative bias by symmetry, is \(\Gamma=(4n_b/\kappa)[\cosh(\psi_s/2)-1]\). It has units particles per area. The signed excess charge divided by elementary charge, in contrast, is
For positive surface charge the negative counterion excess and positive coion depletion follow by taking half the sum and difference of these two measurements. At small \(\psi_s\), the net charge excess is linear in voltage while \(\Gamma\) is quadratic: the two ion species redistribute in opposite directions before appreciable neutral salt adsorption appears. Reversing the bias swaps which species is enriched but leaves the total ion-number excess unchanged. Thus a mass-sensitive and a charge-sensitive measurement give complementary responses even in the same equilibrium model.
At \(\psi_s=2\),
The total excess count can be smaller than the magnitude of countercharge measured in elementary charges because some compensation occurs through removing coions rather than adding counterions. An optical concentration measurement that tracks only total dissolved ion count cannot be converted into net countercharge by multiplying by \(e\). Sampling both quantities, or calibrating the signal against the appropriate species, is needed to test the adsorption prediction. The derivation assumes the same dilute reservoir as the planar Poisson–Boltzmann solution and should not be applied unmodified to a cell with fixed small ion inventories.
Tutorial · infer a screening length and check the model
Use two potential measurements at finite bias
In a 298 K symmetric electrolyte, \(\tanh[eV(z)/(4k_BT)]\) decreases from 0.30 to 0.15 over 8.0 nm. Infer the screening length, and reconstruct the two physical voltages. Why is taking a raw voltage ratio slightly different?
Work through the solution
The transformed profile decays exponentially, so
Since \(4k_BT/e\simeq102.7\) mV, the voltages are \(102.7\operatorname{artanh}(0.30)=31.8\) mV and \(102.7\operatorname{artanh}(0.15)=15.5\) mV. Their physical ratio is about 0.488 rather than 0.500. Inferring a linear-log decay using only these points gives a biased length. Repeating at smaller voltages would test convergence towards the same result without assuming the nonlinear transformation.
Which capacitance was measured?
At low bias a diffuse model independently predicts 0.080 F/m² but a low-frequency measurement gives 0.050 F/m². Infer the compact capacitance of the ideal series model. What would make this inversion impossible with positive capacitances?
Work through the solution
From the reciprocal difference \(1/c_s=20-12.5=7.5\) m²/F we obtain \(c_s=0.133\) F/m². A measured capacitance larger than the predicted diffuse one would imply a negative reciprocal compact capacitance in this two-positive-series model. Check the normalisation area, frequency response, adsorption or additional parallel charging processes before assigning a negative parameter. To distinguish the two capacitances experimentally, vary reservoir concentration at fixed temperature and compare the predicted \(\sqrt{n_b}\) trend of the diffuse contribution with the remaining offset in reciprocal capacitance.