Fundamentals / Physics / Thermodynamics and statistical physics / Statistical mechanics from microscopic counting to material response

Rotational and vibrational populations in a molecular gas

A pressure thermometer and a calorimeter do not count molecular degrees of freedom in the same way. A dilute diatomic gas can retain nearly ideal pressure while its heat capacity changes appreciably as discrete internal levels become populated. Build the molecular partition function, derive the rotor and oscillator contributions, and infer temperatures from line populations without treating spectral intensity as a direct state count.

When a molecule's partition function factorises

Assume a dilute gas of stable diatomic molecules with weak interparticle interactions. Approximate one molecule's Hamiltonian by independent translational, rotational, vibrational and electronic parts. This requires a bond sufficiently stiff that rotation does not greatly alter vibrational energy and a temperature well below electronic excitations or dissociation when the electronic factor is treated as constant. If energies add and allowed states form a product, Boltzmann factors multiply. Thus \(q=q_{\rm tr}q_{\rm rot}q_{\rm vib}q_{\rm el}\), \(Z_N\simeq q^N/N!\) in the dilute classical translational regime. The logarithm converts this product into additive free energies, energies and heat capacities.

The translational factor \(V/\lambda_T^3\) provides the volume derivative and hence ideal pressure \(Nk_BT/V\). A volume-independent internal factor changes neither that derivative nor the associated translational equation of state. It does change entropy, chemical potential and calorimetry. The molar heat capacities satisfy \(C_p-C_V=R\) for a fixed-composition ideal gas, even when both vary strongly with temperature. Dissociation, chemical equilibration or significant intermolecular interactions can change the conclusion for the measured sample.

One danger is double-counting states. Angular momentum orientations belong to rotational degeneracy, oscillator quanta to vibration, electronic spin and nuclear exchange symmetry may constrain one another. A constant electronic degeneracy contributes an additive entropy \(Nk_B\log g\) but no internal energy or heat capacity at fixed level energies. A large heat capacity is evidence for energetically separated states becoming populated, not just for a large number of exactly degenerate states.

Derive the quantum rigid-rotor contribution

For a molecule of moment of inertia \(I\) about its centre of mass, rotational Hamiltonian is \(\hat L^2/(2I)\). Angular momentum eigenvalues are \(\hbar^2J(J+1)\), with \(2J+1\) projections at fixed \(J=0,1,\ldots\). Define rotational temperature \(\theta_r=\hbar^2/(2Ik_B)\). For distinguishable nuclei and a common nuclear spin factor omitted, the rotational sum and populations are

\[q_r=\sum_{J=0}^\infty(2J+1)e^{-\theta_r J(J+1)/T},\]
\[p_J=(2J+1)e^{-\theta_r J(J+1)/T}/q_r .\]

At high temperature the populated range contains many adjacent \(J\) values. Replacing the sum with an integral and substituting \(u=J(J+1)\) gives

\[q_r\simeq T/\theta_r.\]

Hence \(U_r\simeq Nk_BT\), \(C_{V,r}\simeq Nk_B\), the classical result for two independent rotational kinetic energies of a linear object. At low temperature only \(J=0\) and \(J=1\) matter. Their degeneracies and gap \(2k_B\theta_r\) give \(q_r\simeq1+3e^{-2\theta_r/T}\) and an exponentially vanishing heat capacity. Keeping the degeneracy three is essential for both its magnitude and the temperature of its turn-on.

For an illustrative heteronuclear rotor with \(\theta_r=85\) K, direct summation at 20 K gives \(q_r=1.00061\) and \(C_{V,r}=0.0440k_B\) per molecule. At 90 K the corresponding values are 1.471 and 1.063. At 300 K the heat capacity is 1.002. A small overshoot above the classical rotational value is possible during the crossover. A model that simply switches from zero to one classical degree contribution at \(T=\theta_r\) misses the entire smooth population redistribution and cannot predict line ratios.

The most populated \(J\) need not be zero, despite increasing energies, because the projection multiplicity increases with \(J\). Viewing the numerator as a smooth function of \(J\) gives \(J_{\rm peak}\simeq[\sqrt{2T/\theta_r}-1]/2\), to be checked against neighbouring integer values. The estimate is unreliable if it predicts only one or two populated levels. Computing a short discrete sum costs little and reveals its own truncation error through the final omitted weights.

Derive oscillator energy and heat capacity from a geometric series

Near its bond-length minimum approximate the interaction by a spring. With reduced mass \(m_r\) and angular vibration frequency \(\omega_v\), quantum energies are \(E_n=\hbar\omega_v(n+1/2)\). Define \(\theta_v=\hbar\omega_v/k_B\). Summing the resulting geometric series and differentiating gives

\[q_v=\frac{e^{-\theta_v/(2T)}}{1-e^{-\theta_v/T}},\]
\[\frac{U_v}N=k_B\theta_v\left(\frac12+\frac1{e^{\theta_v/T}-1}\right),\]
\[\frac{C_{V,v}}{Nk_B}=\frac{x^2e^{-x}}{(1-e^{-x})^2},\]
\[x=\theta_v/T .\]

The zero-point term contributes energy but no heat capacity at fixed frequency. For \(x\ll1\) the heat capacity approaches \(k_B\) per independent vibrational mode, comprising kinetic and potential contributions. For \(x\gg1\) excitation is too costly and the heat capacity behaves as \(k_Bx^2e^{-x}\). A molecule can still vibrate quantum mechanically in its ground state while contributing virtually no vibrational heat capacity. A calorimeter measures sensitivity of mean energy to temperature and need not see the ground-state motion.

Take \(\theta_v=3000\) K. At \(T=300\) K the vibrational contribution is only \(0.00454k_B\), while at 1200 K it reaches \(0.609k_B\). Combining with the earlier rotor gives molar \(C_V\) approximately \(2.507R\) at 300 K and \(3.109R\) at 1200 K, assuming stable composition and frozen electronic structure. For acoustic measurements the ideal adiabatic ratio \(\gamma=(C_V+R)/C_V\) then decreases from about 1.399 to 1.322. An acoustic drive faster than vibrational relaxation can measure a frequency-dependent effective ratio because internal populations fail to remain equilibrated through a compression cycle.

Compare this single oscillator with the frequency distribution in the lattice heat-capacity plot

Nuclear exchange and the symmetry number

For a homonuclear molecule, rotating its classical orientation by half a turn end for end does not create a second distinct arrangement. In a high-temperature rotational count a symmetry number two therefore divides the distinguishable-nuclei rotor partition function once the compatible spin states are accounted for. Since this factor is constant with temperature it shifts entropy and chemical potential, but not the classical rotational energy or heat capacity. At low temperature it is important to treat actual quantum parity, not divide every level by two.

A homonuclear diatomic rotational wavefunction acquires a factor \((-1)^J\) under exchange of nuclei. The complete state also includes nuclear spin, electronic and vibrational parts. For ordinary molecular hydrogen in its electronic and vibrational ground state the protons are spin-half fermions. Antisymmetry pairs even \(J\) with the single antisymmetric spin singlet and odd \(J\) with the three symmetric triplet spin states. In true spin-conversion equilibrium the rotor sum uses weights one or three in addition to \(2J+1\). At temperatures large compared with rotational spacing, even and odd \(J\) sectors have nearly equal rotational sums and the equilibrium odd-to-even population ratio approaches three.

Conversion between spin species can be slow. A rapidly cooled sample may preserve its prepared fractions rather than attain spin equilibrium. Then compute separate parity-restricted partition functions for fixed species numbers, and average their thermal observables with the frozen proportions. Allowing the total odd fraction to relax yields a different heat capacity, including the energy liberated by conversion. Two experiments on chemically identical hydrogen can consequently report different heating curves because their preparation constrains different internal sectors.

Use intensities only after accounting for the instrument

An absorption line originating from level \(J\) has a strength depending on more than its population. Transition moment, polarisation, transition frequency, stimulated emission correction, instrument response and path length can all enter. Suppose line strengths and detector factors have been divided out to yield quantities proportional to level populations \(N_J\). Then a straight-line fit of \(\log[N_J/(2J+1)]\) against \(J(J+1)\) has slope \(-\theta_r/T\) for the simple heteronuclear model. Its intercept depends on total particle number, partition function and residual instrumental gain.

For \(\theta_r=10\) K, a measured corrected ratio \(N_2/N_0=2.00\) implies \(2=5e^{-60/T}\) and \(T=65.5\) K. Omitting the factor of five would make an upper population larger than the lower one appear incompatible with positive temperature. The inferred temperature assumes the rotational populations are equilibrated at one temperature; an optically pumped or rapidly expanding sample may have different rotational and translational distributions.

A plot over several \(J\) values can test whether one slope is adequate. Curvature may come from centrifugal distortion, line saturation, unresolved overlap, multiple temperatures or a wrong nuclear-spin degeneracy. Alternating residuals for even and odd \(J\) indicate a different physical problem from a smooth quadratic residual against \(J(J+1)\). Repeat with lower optical depth to isolate saturation, and use independently measured transition frequencies to fix level energies before fitting populations.

Recover molecular translation separately from internal structure

In a low-density molecular beam, the translational speed distribution is often easier to measure than the internal populations. For an equilibrium gas leaving a small opening into vacuum, the molecular flux is weighted by the normal velocity. Fast molecules reach and cross the aperture more frequently, so the distribution of speeds in the beam differs from the Maxwell speed distribution inside the reservoir. The mean translational energy of molecules in an effusive beam is \(2k_BT\), whereas the bulk mean is \(3k_BT/2\). This selectivity occurs even when rotational and vibrational populations remain canonical.

To derive the difference, start with the bulk velocity density proportional to \(e^{-mv^2/(2k_BT)}\). Write the outward normal speed as \(v\cos\theta\), integrate over the outward hemisphere and include the velocity-space shell factor \(v^2dv\). The resulting beam speed density is proportional to \(v^3e^{-mv^2/(2k_BT)}dv\), while the original bulk speed density has \(v^2\). Taking a ratio of Gaussian moments gives the stated energy. Comparing a beam energy to the wrong bulk prefactor would yield a temperature one third too high.

If the aperture is small compared with the mean free path and transition-detection efficiency is independent of speed after correction, internal state probabilities factor out of this flux weighting. A rotational population ratio can then report the reservoir temperature while the observed mean translational energy follows the effusive weighting. In a dense nozzle undergoing many collisions, expansion can cool translation and rotation differently. An inferred rotational and translational temperature disagreement is therefore not automatically bad calibration; first identify whether the beam is effusive, collisionally expanding or selectively detected.

As a bench example, a beam mean translational energy of 0.060 eV corresponds to approximately 348 K under effusion, using \(k_B=8.6173\times10^{-5}\) eV/K. Treating it as the bulk mean would give about 464 K. Compare against a population ratio from two corrected lines spanning \(80k_B\) kelvin and equal degeneracies. At the two temperatures the predicted ratios are about 0.795 and 0.842. Resolving this difference demands a relative line calibration appreciably better than six percent even though the two erroneous temperature interpretations differ by more than one hundred kelvin.

An isotope mixture reveals which spectral changes affect entropy

Compare two isotopic forms with the same approximate electronic potential surface. Bond force constant and equilibrium bond length then remain nearly unchanged while reduced nuclear mass changes. The harmonic vibrational frequency scales as \(m_r^{-1/2}\), while the rotational temperature scales as \(m_r^{-1}\). Consequently vibration and rotation respond differently to the same isotope substitution. Their shifts can jointly test whether two sets of spectral features genuinely belong to the same molecular carrier.

Suppose the reduced mass rises by a factor 1.21. A vibrational line at 2000 inverse centimetres moves approximately to 1818 inverse centimetres, and a rotational constant initially 2.00 inverse centimetres moves to 1.65 inverse centimetres. The vibrational characteristic temperature follows from \(hc\widetilde\nu/k_B\), about 1.4388 K per inverse centimetre. At room temperature the two vibrational gaps still greatly exceed thermal energy, so the vibrational heat capacity can remain small even though the spectral isotope shift is easy to resolve.

The zero-point energies nevertheless differ. For this vibrational example their difference is \(hc(2000-1818)/2\) per molecule, corresponding to about 131 kelvin in thermal units or 1.09 kJ/mol. Such offsets cancel within a fixed-species heat-capacity derivative but can matter to comparisons of chemical equilibrium or isotopic exchange. An analysis that discards all constant energy offsets independently in each molecular species can corrupt a reaction free energy unless it restores a consistent reference across reactants and products.

For a thermal entropy contribution from this one oscillator use \(S_v=k_B[(n+1)\log(n+1)-n\log n]\) with \(n=1/(e^x-1)\). This follows by inserting \(U_v\) and \(\log q_v\) into \(S=k_B\log q+U/T\); the zero-point contributions cancel exactly. Thus the measured isotope shift can change vibrational entropy via occupancy even while the zero-point offset itself contributes no entropy. It is helpful to evaluate all three quantities—energy difference, entropy difference and heat-capacity difference—rather than presume that a line shift must have the same thermodynamic role in each.

An internal relaxation time appears in frequency-dependent calorimetry

The equilibrium partition function assumes internal mode populations re-equilibrate on times short compared with the measurement. Model one slower internal degree by an internal energy \(U_s\) relaxing toward its equilibrium value at the instantaneous translational temperature \(T\), with \(\dot U_s=[U_{s,\rm eq}(T)-U_s]/\tau_s\). For a small oscillation around \(T_0\),

\[\delta U_{s,\rm eq}=C_s\delta T.\]

In the \(e^{-i\omega t}\) convention, the complex internal heat capacity and the total measured capacity including an instantaneous background \(C_f\) are

\[C^*(\omega)=C_f+\frac{C_s}{1-i\omega\tau_s}.\]

At low frequency the capacity is \(C_f+C_s\). At high frequency the slow internal energy cannot follow and the apparent in-phase capacity approaches \(C_f\). Its out-of-phase component peaks at \(\omega\tau_s=1\), where real and imaginary increments equal \(C_s/2\). The structure resembles dielectric relaxation because both arise from one relaxing state variable driven by a controlled sinusoid. It follows here from an explicit energy-exchange model and its assumptions.

Take a molar fast contribution \(2.50R\), slow equilibrium contribution \(0.60R\) and relaxation time 2 ms. The full equilibrium value is \(3.10R\). At about 79.6 Hz the real measured capacity is \(2.80R\) and the imaginary increment magnitude \(0.30R\). A heat pulse much shorter than two milliseconds initially raises the temperature as if the capacity were close to \(2.50R\), then energy flows into the internal mode. A slow calorimetric ramp can be perfectly consistent with a faster acoustic measurement that infers a smaller active capacity.

A sample container connected to a thermal bath produces its own complex temperature response even if molecular populations are always equilibrated. Disentangle those effects by calibrating the empty cell or an inert reference gas across the same frequency range, changing pressure to alter collision-mediated internal-relaxation time, and checking the predicted equilibrium limit from independently known level spacings. A mechanical resonance in the apparatus can be separated by varying cell geometry while keeping gas composition fixed. Fitting one imaginary peak to a molecular relaxation model without these controls does not uniquely determine the microscopic relaxation time.

How a line ratio and a calorimeter constrain degeneracies differently

Two groups report a low-energy excited manifold with dimensionless population ratio \(r=N_1/N_0\) at two temperatures. A single ratio determines only \(r=(g_1/g_0)e^{-\Delta/(k_BT)}\), so changing the assigned degeneracy changes the inferred gap. Taking the log ratio at two known temperatures removes a common degeneracy factor. The slope of \(\log r\) against \(1/T\) is minus the gap in kelvin, and the intercept is the log degeneracy ratio if the line-strength calibration and equilibrium assumptions hold.

For illustrative values \(r=0.300\) at 100 K and \(r=0.949\) at 200 K, the log change is approximately 1.152. Dividing by the inverse-temperature change magnitude 0.005 per kelvin gives \(\Delta/k_B\simeq230\) K. Inserting the first ratio gives \(g_1/g_0\simeq3.00\). The same two-manifold model predicts a dimensionless heat capacity \(x^2r/(1+r)^2\) per molecule. At 100 K it is about 0.94, a separate calorimetric prediction independent of the absolute number of detected photons.

A third temperature materially improves the test. An unseen nearby manifold or a line strength that changes with instrumental settings may fit two exact population ratios but produce curvature and excess heat capacity elsewhere. Spectroscopy resolves ordered energy differences while calorimetry sums energy variances over all accessible states. Their combination offers more information than adding further precision to one population measurement under the same ambiguous degeneracy assumption.

Compress a gas without pretending its heat capacity stays constant

A reversible adiabatic compression is often summarised by a fixed exponent \(\gamma\). That power law assumes temperature-independent heat capacities along the path. Molecular populations give a direct case where the exponent changes. For an ideal gas at fixed composition,

\[dS=C_V(T)dT/T+Nk_B\,dV/V.\]

Along a reversible adiabatic path set the sum to zero and integrate. The volume ratio is determined by an integral of measured or calculated \(C_V(T)/T\), not by a universal constant exponent across every temperature.

As an illustrative calculation approximate translation and fully active rotation by \(C_V=2.5Nk_B\) plus one harmonic vibrational mode with \(\theta_v=3000\) K. Heating from 300 to 1200 K at constant entropy gives a volume contraction factor from the fast degrees alone of \(4^{2.5}=32\). The vibrational entropy difference adds another factor \(e^{\Delta S_v/(Nk_B)}\). At 300 K the oscillator entropy is only about \(0.00050k_B\), while at 1200 K it is about \(0.309k_B\). The combined estimate requires \(V_i/V_f\simeq43.6\), a substantially larger compression than the frozen-vibration approximation predicts.

This comparison assumes ideal gas throughout and no dissociation, conditions to be checked in a real large compression. It nevertheless identifies the mechanism: part of the compression work goes into levels that were effectively inactive initially. Using the final high-temperature heat capacity across the whole path would err in the opposite direction by assigning that energy storage to the low-temperature portion as well. The entropy integral correctly weights each temperature interval by its actual internal population response.

A numerically stable solution can avoid differentiating noisy calorimetry. Integrate the entropy increment from tabulated heat capacities in the log-temperature variable. Compare an adaptive integral with a refined straightforward grid, paying particular attention to the rotational or vibrational crossover scale. Alternatively compute endpoint entropies from partition functions when an independently justified spectral model exists. Agreement between calorimetric integration and spectroscopy-derived endpoint entropy checks both assignments without demanding exact agreement of noisy pointwise derivatives.

Experimental pressure also checks the endpoint calculation independently. After equilibration, the ideal equation of state predicts \(p_f/p_i=(T_f/T_i)(V_i/V_f)\), approximately 174 for this idealised path. Finite heat leakage or a pressure-dependent nonideality can change that value. A rapid adiabatic compression can be irreversible even if little heat leaves the chamber, and then the measured entropy can increase. Distinguish a reversible reference calculation from an actual rapid piston protocol before using a mismatch to infer missing molecular levels.

An independent isotropic acoustic test at a fixed initial temperature infers \(\gamma\) from the small-amplitude sound speed \(c_s^2=\gamma RT/M\), where \(M\) is molar mass. At fixed molecular mass a decrease of \(\gamma\) from 1.40 to 1.32 at the same temperature would lower sound speed by the square root of their ratio, roughly three percent. That comparison must truly hold temperature fixed: the large direct thermal dependence of sound speed can easily exceed the internal-mode effect. Frequency-resolved acoustics can see part of a vibrational mode freeze dynamically while equilibrium spectroscopy still predicts its population. Record both phase velocity and acoustic attenuation if the aim is to identify a relaxation time. Across the relaxation band, dispersion without the corresponding dissipative response should prompt a check of transducer phase calibration and acoustic boundary conditions.

Read the rotational level spacing from thermal energy storage

Sum the discrete levels of a linear rotor and compare the heat capacity with equipartition as temperature rises.

Tutorial · Identify a rotor inertia from spectral spacing

For a heteronuclear linear rotor the lowest pure rotational transition has ordinary frequency 120 GHz. Infer \(\theta_r\), the moment of inertia and the expected \(J=1\) to \(J=0\) population ratio at 10 K. How could an isotope substitution test the interpretation?

Use the transition gap and keep angular and ordinary frequency distinct

The gap is \(2k_B\theta_r=h\nu\), so \(\theta_r=2.88\) K and \(I=\hbar^2/(2k_B\theta_r)=1.40\times10^{-46}\) kg square metres. The population ratio is

\[3e^{-5.76/10}=1.69.\]

The upper manifold contains more molecules even though each of its levels has lower individual Boltzmann weight. Increasing reduced mass at nearly fixed bond length increases \(I\), reducing the transition frequency approximately inversely with reduced mass. A vibrational frequency from the same spring would scale instead with inverse square root of reduced mass.

Tutorial · Infer an excitation temperature from calorimetry

A gas of linear molecules has molar \(C_V=2.91R\) at a temperature where translation and rotation contribute \(2.50R\). Neglect electronic excitation and estimate the characteristic temperature of a single harmonic vibration in units of measurement temperature. Would a measured \(C_p\) be usable unchanged?

Invert the oscillator contribution and verify its feasible range

The remaining \(0.41R\) lies between zero and the one-mode classical limit \(R\). Solve \(x^2e^{-x}/(1-e^{-x})^2=0.41\) on positive \(x\). At 3.0 it is 0.496 and at 3.5 it is 0.393, placing the root near 3.41. Thus \(\theta_v\) is about 3.41 times measurement temperature. Use several temperatures to verify the characteristic value and frozen-composition model. For ideal gas at fixed composition, subtract \(R\) from \(C_p\) before applying this constant-volume balance. Latent processes, reaction and internal relaxation would require an extended model.

Tutorial · Distinguish equilibrium hydrogen from a frozen spin mixture

At low temperature only \(J=0\) in the even sector and \(J=1\) in the odd sector contribute. Use \(\theta_r=85\) K and \(T=30\) K. Estimate the equilibrium odd fraction and compare the energy stored in a sample frozen at a three-quarter odd fraction, measured relative to the common lowest even state.

Normalise both sectors and identify the energy released on conversion

The relative weight of \(J=1\) is \(3(2J+1)e^{-170/30}=0.0311\); the even ground state has weight one. The equilibrium odd fraction is approximately 0.0302. A frozen sample at odd fraction 0.75 stores about \(0.75(170)k_B=127.5k_B\) kelvin of rotational energy per molecule, versus about \(5.1k_B\) kelvin for equilibrium. The excess expressed per mole is roughly \(R(122.4\,{\rm K})=1.02\) kJ/mol.

The frozen low-temperature heat capacity can be small even while substantial energy remains trapped in the odd sector. A calorimeter monitoring a slowly converting sample measures time-dependent heat release, not simply the derivative of a stationary restricted partition function. Measure the spin fraction independently or vary equilibration time before comparing its heat curve with an equilibrium prediction.

Cambridge Statistical Physics · molecular partition functions and internal degrees of freedom