Define a material field at an intermediate scale
Choose a volume large enough to average over microscopic moments and small enough to resolve the sample's macroscopic variation. Let \(\boldsymbol M(\boldsymbol r)\) be the vector sum of moments within it divided by its volume. Its units are \(\mathrm{A/m}\). A permanent aligned collection may maintain \(\boldsymbol M\) without an applied field. An induced collection may point with or against the applied field. Electric charges need not traverse the entire sample in a closed macroscopic wire for either mechanism. Electron orbital moments and spin contribute to the measured moment; for a classical exterior field calculation any small magnetic dipole has the same leading field once its moment is specified.
A bar of volume \(8.0\,\mathrm{cm^3}\) with uniform \(M=2.0\times10^4\,\mathrm{A/m}\) has total moment \(m=0.160\,\mathrm{A\,m^2}\). A torsion balance in a uniform \(10\,\mathrm{mT}\) transverse field would measure a maximum torque \(1.60\times10^{-3}\,\mathrm{N\,m}\) if its moment stayed fixed. Dividing a measured torque by field and sample volume infers the component normal to the external field. Alignment of a previously soft material could instead alter the very moment being measured. Distinguishing fixed-source and induced-response experiments will matter when we calculate mechanical energy.
Derive the bound sources by integration by parts
Sum the dipole vector potentials over a material region \(V\). With observation point outside the matter, a volume element contributes \((\mu_0/4\pi)\boldsymbol M(\boldsymbol r')\times(\boldsymbol r-\boldsymbol r')dV'/R^3\), where \(R=|\boldsymbol r-\boldsymbol r'|\). Note that \(\nabla'(1/R)=(\boldsymbol r-\boldsymbol r')/R^3\). Apply the identity \(\nabla'\times(\boldsymbol M/R)=(\nabla'1/R)\times\boldsymbol M+(\nabla'\times\boldsymbol M)/R\). The desired first cross product is minus the first term on the right. A volume integral of a curl is the surface integral of outward normal crossed with the vector. This yields
Comparing with the ordinary current potential identifies \(\boldsymbol J_b=\nabla\times\boldsymbol M\), in A/m², and \(\boldsymbol K_b=\boldsymbol M\times\boldsymbol n\), in A/m. The first can vanish throughout a uniformly magnetised object, while the second closes around its exterior. A literal set of microscopic loops illustrates the sign. Neighbouring loop-edge currents cancel between equal adjacent moments, whereas their edges on the outer boundary remain uncompensated. When the moments vary slowly, interior cancellation is incomplete and yields the curl.
An alternative treatment extends \(\boldsymbol M\) by zero outside. Its distributional curl already includes the surface sheet at the discontinuity. Use either this full derivative or the separate bulk and surface integrals; including both descriptions simultaneously doubles the boundary source. At an internal interface with chosen normal from material 1 to 2 the two surface contributions combine to \((\boldsymbol M_1-\boldsymbol M_2)\times\boldsymbol n\). This expression is unchanged by interchange of the two labels accompanied by reversal of the normal.
Work through a uniformly magnetised cylinder
Let a finite circular cylinder of radius \(a\) and length \(2l\) have \(\boldsymbol M=M\hat{\boldsymbol z}\). On the curved side \(\hat{\boldsymbol z}\times\hat{\boldsymbol s}=\hat{\boldsymbol\varphi}\), hence \(K_\varphi=M\); on its end faces the cross product vanishes. The cylinder is equivalent, for its magnetic field, to a finite solenoid having turn-current per unit length \(M\). A strip of sidewall of height \(dz'\) carries ring current \(M\,dz'\). Insert this into the axial finite-loop field from the first chapter and integrate from \(-l\) to \(l\).
At the centre \(B_z=\mu_0M l/\sqrt{a^2+l^2}\). For \(a=10\,\mathrm{mm}, l=20\,\mathrm{mm}\) and \(M=1.0\times10^4\,\mathrm{A/m}\), the value is \(11.24\,\mathrm{mT}\), below the long-cylinder limit \(12.57\,\mathrm{mT}\). At the end centre \(z=l\), only the first term contributes, giving \(6.10\,\mathrm{mT}\). A probe just outside the end and one just inside see the same normal \(\boldsymbol B\) in the limit, even though the auxiliary normal \(\boldsymbol H\) can jump because \(\boldsymbol M\) ends abruptly. The field near an edge is not uniform and can vary strongly with the sensor's position. Stating the axis and position is therefore essential when inferring magnetisation from a reading.
Use a nonuniform sample to separate bulk and surface effects
For an infinitely long cylinder set \(\boldsymbol M=M_0(s/a)\hat{\boldsymbol\varphi}\) for \(s<a\), zero outside. The cylindrical curl gives \(J_{b,z}=s^{-1}\partial_s(sM_\varphi)=2M_0/a\) in the bulk. The side normal is \(\hat{\boldsymbol s}\), so \(K_{b,z}=-M_0\). Integrated over a cross section the bulk current is \(2\pi aM_0\); the axial sheet supplies \(-2\pi aM_0\). Their cancellation means an exterior Amperian circle sees zero enclosed current. Its zero field follows from symmetry and the absence of externally imposed fields.
Inside, a circle at \(s\) encloses \(2M_0\pi s^2/a\). Dividing its circulation by \(2\pi s\) gives
Thus \(\boldsymbol H=\boldsymbol B/\mu_0-\boldsymbol M=0\) both inside and outside here, despite nonzero interior \(\boldsymbol B\). For \(a=20\,\mathrm{mm},M_0=500\,\mathrm{A/m}\), the bulk current density is \(5.0\times10^4\,\mathrm{A/m^2}\), total bulk current \(62.8\,\mathrm A\), and field just inside the rim \(0.628\,\mathrm{mT}\). A magnetometer outside reports zero within this ideal geometry. Such a null measurement establishes neither zero \(\boldsymbol M\) nor absence of all microscopic moments.
Compare a field map and a pickup-coil measurement
A stationary inductive pickup near a stationary permanent magnet has no emf from that static flux alone. An experiment can move the sample, rotate it or modulate a known magnetising field to produce \(-N\,d\Phi/dt\). A Hall sensor or calibrated magnetometer can instead respond to a static field. To compare methods, place a small pickup near the axis of the preceding finite cylinder and oscillate its axial position as \(z=z_0+\zeta\cos\omega t\). For \(\zeta\) small, the flux per turn is approximately \(A_p[B_z(z_0)+\zeta B'_z(z_0)\cos\omega t]\). The voltage amplitude is \(N A_p\zeta\omega |B'_z(z_0)|\). It measures a gradient multiplied by displacement amplitude, whereas a static Hall value measures the field itself.
At the symmetric cylinder centre \(B'_z(0)=0\), so the first harmonic vanishes even though the field is strong. Expanding one more order gives a constant shift and a second harmonic proportional to \(B''_z(0)\zeta^2\), since \(\cos^2\omega t=(1+\cos2\omega t)/2\). Finding a very small first harmonic at the centre is therefore a check on positioning and symmetry. It is not a calibration of zero magnetisation. Far from the ends, a measurement of the whole sample's dipole field instead yields \(\int\boldsymbol M\,dV\). Different internal distributions can share that integral while producing different nearer fields. Report the geometry, the actual observable and the assumed uniformity whenever quoting a single recovered value of \(M\).
Examine bound currents and field measurements in a magnetised sample
Use fictitious poles to compute a measurable field
There is a second useful representation of a given magnetisation. In a simply connected region without free current, \(\nabla\times\boldsymbol H=0\), so choose \(\boldsymbol H=-\nabla\psi\). Substitution into \(\nabla\cdot(\boldsymbol H+\boldsymbol M)=0\) gives
The potential therefore behaves mathematically as if it were produced by volume density \(\rho_m=-\nabla\cdot\boldsymbol M\) and surface density \(\sigma_m=\boldsymbol M\cdot\boldsymbol n\). The surface term follows by extending the magnetisation by zero across the boundary, or by requiring continuity of \(B_n=\mu_0(H_n+M_n)\). Integrate these densities with kernel \(1/(4\pi R)\) to obtain \(\psi\); there is no factor of \(\epsilon_0^{-1}\) because these conventions assign \(\psi\) units of amperes. The resulting \(\boldsymbol H\) must be converted back to \(\boldsymbol B\), adding \(\mu_0\boldsymbol M\) inside matter.
For the uniformly magnetised finite cylinder the pole representation puts densities \(+M\) and \(-M\) on the two end faces, none on the sides. Earlier the bound-current representation placed current on the curved side and none on the ends. They predict the same physical field. A single uniformly loaded disk of pole density \(\sigma_m\) at \(z=0\) has on-axis scalar potential \(\psi=\sigma_m[\sqrt{z^2+a^2}-|z|]/2\), obtained by integrating \(2\pi s\,ds/[4\pi\sqrt{s^2+z^2}]\). Its derivative gives
At the disk plane the two one-sided fields jump by \(\sigma_m\), precisely the normal-\(H\) jump demanded by the magnetisation.
At the midpoint of the cylinder add the two oppositely charged disks. Their axial fields both point opposite the magnetisation and total \(H_z=-M[1-l/\sqrt{a^2+l^2}]\). Adding \(M\) yields the same \(B_z\) as the side-current integral. At \(l=2a\), this internal demagnetising field is \(-0.1056M\); for a very short cylinder \(l\ll a\) it approaches \(-M\). A uniformly specified magnetisation in a thin disc therefore produces only a small normal \(B\) at its centre despite the large \(M\) and \(H\) terms that nearly cancel. In practice, a soft magnetic material in such a shape may choose a nonuniform magnetisation or domains. The calculation describes the field of the imposed distribution; it does not establish that the distribution is a stable material state.
The 'poles' are convenient mathematical source terms, not isolated magnetic charges: adding the effective volume and surface poles over a finite bounded sample gives
North and south effective poles may be far apart, but a surrounding closed Gaussian surface still has zero net magnetic flux. If a model predicts a \(1/r^2\) radial field of one sign through an entire distant sphere around a fully included bar magnet, test whether the opposite face or volume contribution has been accidentally dropped.
Infer the field of a spherical void by subtracting a known sample
Superposition can calculate a local cavity field before introducing a detailed microscopic model. Imagine a large body with uniform imposed magnetisation \(\boldsymbol M\) near an interior point, and remove a small spherical piece. The magnetic field after removal is the original macroscopic field minus the contribution of the excised sphere, provided the surrounding magnetisation stays unchanged. A uniformly magnetised sphere in otherwise empty space alone has uniform internal \(H=-M/3\), as can be derived from its pole distribution \(\sigma_m=M\cos\theta\). At the sphere centre \(\boldsymbol H\) follows by integrating the field from surface elements \(-\sigma_m\hat{\boldsymbol r}\,dA/(4\pi a^2)\). The \(z\)-component involves the spherical average \(\langle\cos^2\theta\rangle=1/3\); transverse contributions vanish by symmetry. The unique dipolar harmonic extends that central value uniformly throughout the sphere.
The sphere's own internal \(B\) is therefore \(2\mu_0M/3\). Immediately after its removal the field in the empty cavity is
This assumes the sphere is small relative to the variation scale of the pre-existing magnetisation and far from the sample's external boundary on its own size scale. A different cavity shape changes the subtraction factor, and a physical bore can rearrange the surrounding magnetisation or admit demagnetising fields from its ends. Local-field interpretations depend on probe geometry as well as material properties.
As a numerical illustration, suppose a permanent or pinned surrounding material has local \(M=1500\,\mathrm{A/m}\) and \(H_{\rm bulk}=400\,\mathrm{A/m}\), aligned. The macroscopic bulk field is \(\mu_0(1900)=2.39\,\mathrm{mT}\). A small spherical empty cavity under the stated frozen-distribution approximation has \(B_{\rm cav}=\mu_0(900)=1.13\,\mathrm{mT}\). Both readings can be correct for the same initial material. A Hall element inserted into a drilled hole measures the field in that hole; labelling it 'the internal material field' without modelling the probe cavity can cause a substantial discrepancy. Small hole volume does not by itself make the local cavity field correction small, since area and inverse-square field factors cancel in the spherical surface integral.
For a final comparison, cut a very thin flat slit perpendicular to \(\boldsymbol M\) instead of a sphere, idealising its lateral dimensions as large relative to its thickness. The facing effective pole sheets produce a strong additional field within the slit. Normal \(B\) stays continuous across its faces, so the vacuum reading tends towards the original normal \(B_{\rm bulk}\) when edge effects and magnetisation changes are negligible. A long narrow cavity parallel to the magnetisation instead tends towards continuity of tangential \(H\) on its long sides. Comparing the sphere and slit is an operational way to understand why \(B\) and \(H\) are different macroscopic variables rather than two symbols for one ambiguous 'magnetic intensity'.
Read the current implied by a magnetisation
Change the magnetisation and compare interior and exterior fields at the surface. Check which tangential or normal field condition is relevant.
Reconstruct an invisible current distribution in a magnetised film
An extended magnetic film fills the slab \(-a<z<a\). A fabrication process leaves a tangential magnetisation \(M_x(z)\hat x\). Let the magnetisation vanish outside. There is no free current in this calculation, and there is no applied field at infinity. A field measurement above the centre of a very wide film can then give nearly zero even when the magnetisation inside varies substantially. Work out both the bound currents and the local magnetic field before deciding what an external zero reading means.
Inside the material the bound volume current is
The upper face has outward normal \(+\hat z\), so its bound sheet current is \(-M_x(a^-)\hat y\). On the lower face the outward normal reverses and the sheet current is \(+M_x(-a^+)\hat y\). Integrating the volume current through the thickness gives \(M_x(a^-)-M_x(-a^+)\). Thus the combined sheet and volume currents sum to zero per unit length across the entire film. This cancellation is independent of how much structure the magnetisation has inside the slab. An alternative derivation extends \(M_x\) by zero beyond the faces and differentiates that piecewise function as a distribution. The jumps generate both surface terms with their proper signs.
For an explicit depth profile take \(M_x=M_0(1+z/a)\). There is a uniform bulk current \(M_0/a\), no lower surface current, and an upper surface current \(-2M_0\). Planar symmetry allows only \(B_x(z)\). Ampère's law gives
Integrating from below the film, where the field vanishes, gives \(B_x=\mu_0 M_0(1+z/a)\) inside. At the upper face the field jumps back to zero. The result also follows directly from \(H_x=B_x/\mu_0-M_x\): its tangential component is continuous wherever there is no free surface current, and there is no volume source for its variation. In this geometry \(H_x=0\) throughout.
Take \(a=0.20\,{\rm mm}\) and \(M_0=2.0\times10^4\,{\rm A/m}\). The interior current density is \(1.0\times10^8\,{\rm A/m^2}\). That large number represents microscopic circulating moments after coarse graining. It does not imply a transport current passing through external electrical contacts. The peak interior field is approximately \(50.3\,{\rm mT}\) just below the upper face, and the average is about \(25.1\,{\rm mT}\). An exterior sensor over the central region of the infinite idealisation reads zero at any height. With a finite lateral extent, currents must close around the film edges. The resulting fringe signal contains shape information and becomes measurable as the probe approaches the rim.
Rotate the magnetisation through ninety degrees so that it now points in the \(z\) direction while its magnitude keeps the same depth profile. Each local curl vanishes. Each face has parallel magnetisation and normal, giving zero bound sheet current. Consequently the solution has zero \(B\) everywhere in the ideal infinite geometry. Within the film \(H_z=-M_z\). In the magnetic-pole construction the two surface pole densities and the bulk density \(-dM_z/dz\) provide precisely that auxiliary field. These two slab examples illustrate a real inverse problem: very different internal magnetic states can produce the same exterior measurement. Knowing the material orientation or imposing a changed external field supplies additional information.
Can two depth profiles with the same average magnetisation be distinguished by an ideal measurement of the tangential magnetic flux through the film thickness?
Work through the solution
Choose a rectangular sensing surface with its normal along \(x\), its height equal to the film thickness, and its length \(w\) along \(y\). The ideal internal flux is \(w\mu_0\int_{-a}^{a}M_x(z)\,dz\). This measurement determines one weighted integral. A constant \(M_0\) and the linear example above give identical results even though the constant profile has only surface currents. A depth-selective measurement would weight the profiles differently. For example, integrating over just the upper half gives \(\mu_0waM_0\) in the constant case and \(3\mu_0waM_0/2\) in the linear case. Actual pickup loops must close outside the sample, so include their full geometry when inferring an internal flux.
Suppose the linear profile relaxes uniformly in amplitude after an aligning field is removed. What information would the integrated voltage of a calibrated pickup provide?
Work through the solution
If the pickup links \(N\) turns with the preceding full-thickness flux and \(M_0\) decays from its initial value to zero, the time-integrated emf has magnitude \(2N\mu_0waM_0(0)\). Faraday's law supplies this integral independently of whether the decay is exponential or has several relaxation times. A finite integration window that ends before zero magnetisation underestimates the initial amplitude unless the residual flux is measured. Leakage from the changing applied alignment field can also drive the loop directly. A reference winding of the same area, measured without the specimen, allows that part of the transient to be estimated.
David Tong, Electromagnetism in Matter, on macroscopic magnetisation and bound currents.
Tutorial on reconstructing material sources
In the nonuniform cylinder let \(M_\varphi=M_0(s/a)^3\) instead. Obtain the bulk current density, the side sheet, the total bound current through the full cross section and the interior field.
Work through the solution
At the wall \(K_{b,z}=-M_0\). Integration gives \(2\pi aM_0\) in the bulk and its opposite on the wall. For an interior circle the enclosed bulk current is \(2\pi M_0s^4/a^3\), giving \(B_\varphi=\mu_0M_0(s/a)^3\). Both total cancellation and dimensional consistency check the result.
Two adjoining media have tangential magnetisations \(400\hat{\boldsymbol x}\) and \(100\hat{\boldsymbol x}\,\mathrm{A/m}\). The normal from 1 to 2 is \(+\hat{\boldsymbol z}\). Find the net bound sheet current and the associated tangential jump of \(\boldsymbol B\) if no free surface current is present.
Work through the solution
The equivalent sheet is
Tangential \(H_x\) is continuous, so
Crossing this difference with the chosen normal gives \(\mu_0\boldsymbol K_b\), matching the microscopic Ampère law.
A long solenoidal sample has known \(M\) only to 5 percent. Can a single Hall reading at the centre establish that its magnetisation is uniform over the entire volume to that accuracy?
Work through the solution
No. The reading is one geometry-weighted integral of the source. Reversing magnetisation can remove a stable external offset, and measurements at several axial positions can test the uniform-cylinder shape, but the single central datum cannot uniquely determine a spatially resolved source. Agreement of a fitted constant at one point supplies no independent uniformity test.