Find a topic
Read the subject in depth
Each volume develops its arguments in sequence, with worked problems and links to experiments.
Inferring parameters and fields from observations
Follow information from a forward model back to its unknowns. Evaluate identifiability, numerical sensitivity and how an additional observation changes the inference.
How the course fits together
- Chapters 1–4
A forward map predicts observations from parameters. Whiten noise before measuring a misfit. Singular directions reveal poorly observed parameter combinations, and regularisation controls their influence.
- Chapters 5–8
Linearise the forward map near a trial parameter and choose measurements that distinguish competing fits. A prior yields a posterior distribution. Profiles ask which physical predictions remain supported as other parameters readjust.
- Chapters 9–12
Evaluate gradients with an adjoint, stop iterations to limit noise amplification, and impose feasible sets or edge-preserving penalties. Resolution analysis asks which features survive the full measurement and reconstruction process.
Chapters
- Forward maps, information and identifiability
Decide what a measurement can tell you before attempting to fit it. Separate nonuniqueness, noise sensitivity and model error.
- Weighted least squares and residual diagnostics
Derive the fitting criterion from measurement error and separate the uncertainty of an estimated mean from the scatter of a new observation.
- Singular systems and the amplification of noise
Identify which patterns survive a forward measurement and which become dominated by uncertainty when inverted.
- Regularisation, resolution and the price of stability
Choose which features to recover, derive the associated filter and quantify the bias introduced by that choice.
- Nonlinear fitting and local models
Derive a Gauss–Newton step, recognise misleading local curvature and use step acceptance to protect a nonlinear fit.
- Design an informative experiment and test its predictions
Choose observations that separate parameters, then check uncertainty against the behaviour of new data.
- Bayesian inversion and the information supplied by a prior
Combine an explicit distribution for the parameters with a noise model. Calculate exactly which uncertainties an observation reduces.
- Predictions, parameter profiles and nonlinear uncertainty
Calculate intervals for a quantity of interest, then find where a linear covariance approximation loses the geometry of a nonlinear fit.
- Adjoint gradients through a forward solver
Differentiate a scalar objective with respect to many parameters without recomputing a separate perturbed solution for each one.
- Iteration as a regulariser
Derive the spectral action of a matrix-free iteration and explain why more iterations can eventually make an inverse estimate worse.
- Constraints, sparse signals and edge-preserving penalties
Derive a solution at a bound, a soft-threshold rule and the behaviour of a total-variation penalty at a material interface.
- A reconstruction audit from observations to a defensible claim
Combine residuals, resolution, uncertainty and independent predictions to decide what one spatial experiment establishes.
Further chapters and interactive tutorials
- Choosing regularisation when the true answer is hidden
Derive two parameter choices from different information, then see how an excellent fit to sensor data can restore the noise in a weakly visible mode.
- Learning a drifting temperature from a sequence of readings
Derive the scalar Kalman update by completing the square and see how process uncertainty controls memory of the past.
- When a single uncertainty interval hides two explanations
Start from a squared-amplitude measurement, derive the full posterior and design a second observation capable of identifying the sign.
- How model error masquerades as a fitted physical parameter
Project an omitted spatial effect into the fitted parameter space. Work out when residual checks reveal the omission and when they are silent.
- Predicting a new measurement when the fitted parameters are correlated
Propagate the full posterior covariance to a quantity of interest, distinguish latent and measured uncertainty and select the observation that reduces the uncertainty of the actual prediction.
- Calibrating two instruments when both axes fluctuate
The horizontal axis of a calibration plot is often described as an input. In this experiment it is itself a reading from a second noisy instrument. Infer a straight calibration relation from paired data, derive the metric in which the fit should be performed, and use a change of units to reveal an easily overlooked modelling error.
Computational notebooks
Run the Python calculations in your browser and compare the figures with the derivations.
Problem sheets
Sheets 1–6 accompany the first twelve chapters. The final projects bring several methods together. Attempt each stage before opening its worked solution.
- Which combinations do the data determine?For chapters 1 and 2
Use a null-space argument, a covariance model and a residual calculation to assess three proposed measurements.
- Spectral filtering and recoverable detailFor chapters 3 and 4
Calculate what a reconstruction can borrow from the data and what it assumes when it suppresses a noisy direction.
- Nonlinear estimates and experimental designFor chapters 5 and 6
Distinguish a successful optimisation step from a reliable parameter estimate and a prediction that generalises.
- Which uncertainty came from the experiment?For chapters 7 and 8
Compare a posterior update, a nonlinear prediction and a likelihood profile on problems with exact solutions.
- Derivatives and early stoppingFor chapters 9 and 10
Check a forward solver gradient independently, then decide when its iterative inverse has started fitting noise.
- Edges, decision thresholds and validationFor chapters 11 and 12
Determine whether an apparent feature survives a change of penalty, a noise calculation and an independent test.
- Project · Which thermometer should the laboratory buy?
Separate an unknown common temperature, a calibration contrast and temporal drift. Design a measurement that improves the weakly determined quantity and check whether a small residual signals a trustworthy reconstruction.
- Estimate optical thickness when both measurements count photons
A dim red calibration source is viewed through an absorbing filter and then with the filter removed. Both observations fluctuate. Build the inverse problem directly from the photon counts, profile out the unknown source brightness, and decide how to distribute scarce observation time.
Final synthesis problem · Choose a sensor direction that resolves an unobservable combination
Applied study
Infer parameters from noisy observations and use sensitivity to design a more informative experiment.
From predictions to parameter estimates
A forward problem takes material properties and predicts a response. In an inverse problem the responses have been observed and one or more material properties are unknown. Suppose a model predicts \(g_i(p)\) at observation \(i\), where \(p\) is a vector of parameters. Write \(y_i\) for the measured value and \(s_i>0\) for its estimated standard deviation. With independent Gaussian measurement errors of known variance, the maximum-likelihood fit minimises
The weights put observations with different units or precision on a comparable scale. A small residual says that the chosen parameter fits the observations. To know whether it is the only plausible value, examine how the predictions change as the parameter moves.
Fit a spring and inspect the residuals
A spring in its elastic range has force \(F=kx\). For equally precise force measurements at accurately known extensions, minimising the sum of squares gives \(\sum_i x_i(kx_i-F_i)=0\), hence \(\hat k=\sum_i x_i F_i/\sum_i x_i^2\). At extensions of 1, 2 and 3 mm the measured forces are 1.1, 1.9 and 3.0 N. The fitted stiffness is
Plotting the signed residuals against extension can reveal curvature or a preload that this model omits.
If an unknown preload \(b\) is allowed, fit \(F=b+kx\). The columns of the design matrix are then \(1\) and \(x_i\). Measurements at a single extension can determine \(b+kx\) but cannot distinguish \(k\) from \(b\), however many times the measurement is repeated. Multiple extensions add independent information. For a general linear model a QR or singular-value decomposition solves this least-squares problem without squaring the condition number by explicitly forming the normal equations.
Design a measurement for a nonlinear model
For a nonlinear response, approximate the residual near a trial point by \(r(p+\Delta p)\simeq r(p)+J\Delta p\), with \(J_{ij}=\partial r_i/\partial p_j\). A Gauss–Newton step minimises the norm of this linear expression. A damped step can also penalise the size of \(\Delta p\) when the local linear model gives a poor prediction. Small singular values of the appropriately scaled Jacobian identify parameter combinations that the data barely constrain.
Consider first-order decay \(c(t,T)=c_0e^{-k(T)t}\) with an unknown reference rate \(k_r\) and activation energy \(E\). Write \(k(T)=k_r\exp[-(E/R)(1/T-1/T_r)]\). At \(T=T_r\) the factor multiplying \(E\) vanishes. A complete decay curve at that temperature can estimate \(k_r\), but carries no information about \(E\). Taking measurements on either side of \(T_r\) changes that sensitivity. For a locally linear, full-rank, well-scaled problem with unit-variance normalised errors, \((J^\mathsf{T}J)^{-1}\) approximates parameter covariance. The diagonal estimates uncertainty under the assumed model and noise law.
Problem class
Choose a second spring measurement
A force sensor has an unknown constant offset. Compare measurements at 2 and 2 mm with measurements at 1 and 3 mm. For the latter design, suppose the measured forces are 1.3 N and 3.1 N. Recover the slope and offset. What remains unknown if each extension is sampled only once?
Check rank before fitting the line
Two identical extensions give two identical rows \((1,2)\) and cannot separate slope and offset. At distinct extensions the difference gives \(k=(3.1-1.3)/(3-1)=0.9\) N/mm, then
Two observations exactly fit two unknowns. No residual degrees of freedom remain to estimate measurement noise or check linearity from those data alone.
Know when a sample is informative
At one fixed temperature, \(c=c_0e^{-kt}\). Assume the same absolute concentration uncertainty at every sampling time. At what time is a single concentration measurement most sensitive to \(k\)? Evaluate the result for \(k=10^{-3}\ \mathrm{s}^{-1}\).
Maximise the derivative with respect to the rate
The magnitude is \(c_0 t e^{-kt}\). Its time derivative is \(c_0e^{-kt}(1-kt)\), so it peaks at \(t=1/k=1000\) s. The slope is small at very early times because little decay has occurred. At very late times very little material remains. Relative rather than absolute measurement errors would give a different sampling criterion.
OneSimulation laboratory
Find out what a temperature series identifies
Compare recorded OneSimulation runs on this page. To test your own inputs, download the notebook and model files and run the model in an activated OneSimulation environment.
Fit \(k_r\) and \(E\) simultaneously to five simulated concentration histories with a fixed noise seed. The data-generating values are \(k_r=0.001\) s⁻¹ and \(E=115\) kJ/mol. Keep the same starting guess. Predict which change most increases the standard error of \(E\): doubling noise, or moving the five temperatures closer to their common reference of 323.15 K.
| Temperature range and noise (mol/m³) | Fitted E (kJ/mol) | Standard error (kJ/mol) |
|---|---|---|
| 313.15–333.15 K · noise 0.05 | 114.0367 | 0.3636 |
| 313.15–333.15 K · noise 0.10 | 113.0635 | 0.7228 |
| 321.15–325.15 K · noise 0.05 | 111.1489 | 1.4300 |

In the wide case the five temperatures are spaced by 5 K. In the narrow case they are spaced by 1 K. Use the same 12 sampling times per experiment. Try a different random seed after checking the table. Compare the fitted error bar with the scatter of estimates across several seeds. Increasing the number of repeats probes noise; changing the temperature range also changes parameter identifiability. Inspect the model, residuals and fitting procedure.
Download experiment files (ZIP) Extract the files together and open arrhenius_parameter_estimation.ipynb in a local OneSimulation environment.
Change parameters · Change the laboratory inputs
Change one input at a time and compare the recalculated curves with the argument above. The browser evaluates this small model locally; the accompanying numerical values state its assumptions and reference checks. Reset restores the reference inputs, and the data can be downloaded as CSV.
Problem sheet 3 · Choose between repeating and spreading measurements
Advanced study across the subject
Each sequence connects the course to detailed chapters in neighbouring subjects. The complete course PDF includes their derivations, examples and exercises.
Which field can be recovered from boundary data?
Relate an observation to its spatial sensitivity. Use reciprocity, smoothing with distance and changes of electrode configuration to identify recoverable features.
A measured curve and competing mechanisms
Fit material response, decay and resonant splitting. Design at least one new observation that can distinguish explanations left unresolved by the first experiment.
A worked application in field physics
Relate an electrode measurement to its spatial sensitivity and test which changes in conductivity the readings can resolve.
Which part of a sample changes a four-electrode impedance measurement?
Further reading
Work with the companion test problems and regularisation tools. Inspect the data coefficients and singular values before selecting a truncation or Tikhonov parameter. Per Christian Hansen · Discrete Inverse Problems