A misspecified instrument
Suppose \(d=A x_*+b+\eta\), with zero-mean measurement noise and a deterministic but omitted contribution \(b\). Assume \(A\) has independent columns. Least squares gives
Taking expectations leaves the parameter bias \(A^+b\). The fitted residual is \((I-AA^+)(b+\eta)\). Thus the same model error separates into a component that biases the parameters and an orthogonal component that remains visible to residual checks.
For a single sensitivity column \(a\), decompose \(b=b_\parallel+b_\perp\), where \(b_\parallel=a(a^Tb)/(a^Ta)\). Repeating the measurement reduces independent random error; the deterministic projection remains. Error bars computed solely from measurement variance can become more misleading as more readings are acquired.
Calibration with an omitted offset
Fit \(d_i=m t_i\) at \(t=(1,2,3)\) to observations actually generated by \(d_i=2t_i+0.3\). The unmodelled constant has nonzero projection onto \(t\). The bias is \(0.3(1+2+3)/(1+4+9)=0.12857\), giving fitted slope 2.12857. The residuals at the three points are approximately 0.17143, 0.04286 and −0.08571. Their signed trend suggests a missing intercept. At \(t=6\) the model predicts 12.7714 while the actual law gives 12.3; an apparently modest training residual has grown into a substantial extrapolation error.
Now use a discrepancy exactly proportional to time, \(b_i=0.1t_i\). The fitted slope becomes 2.1 with zero residual at every training point. Additional times under the same model cannot separate the true slope from this contribution. A separate calibration that suppresses the extra physical effect can.
Rotate the missing physics
In a two-reading instrument, the model sensitivity is the unit horizontal vector. Vary the magnitude and direction of the omitted contribution. Observe parameter bias and visible residual separately, and locate cases with the same discrepancy norm but completely different fit diagnoses.
Tutorial on experimental design
Repeat the offset example at symmetric times \((-1,0,1)\). Which part of the fitted result changes?
Worked solution
The constant is now orthogonal to \(t\), giving zero slope bias. The residual is a constant 0.3 in every reading. The experiment has made an offset visible without corrupting the slope.
Can adding an unrestricted discrepancy parameter for every datum solve the identifiability problem?
Worked solution
It permits exact fits for any physical parameter by assigning the remaining signal to the discrepancy. Constrain the discrepancy from theory, independent data or a justified prior to extract the physical parameter.
Read the university treatment
Compare errors that project into a fitted singular direction with errors seen in the orthogonal data residual. Per Christian Hansen · Discrete Inverse Problems