1. Two instruments on three cells
Let \(y_1=x_1+x_2=5,\ y_2=x_2+x_3=7\). (a) Write all exact solutions. (b) Determine whether \(x_3-x_1\) and \(x_1+x_2+x_3\) are identifiable. (c) Name one additional reading that makes the full vector identifiable and prove it.
Test each quantity along the null direction
With \(x_2=t\) all solutions are \((5-t,t,7-t)\). Their directional change is \((-1,1,-1)\). The contrast \(x_3-x_1=2=y_2-y_1\) stays fixed, while the sum \(12-t\) varies. A reading of the total gives a unique \(t\), since its dot product with the null direction is \(-1\). Repeating either original reading cannot remove this null direction.
Try this calculation. Explore the continuum of parameter pairs with the same observed sum, and see how a chosen norm selects one pair.
2. A shared calibration error
Two sensors read the same constant plus independent random errors of variance 1 and a shared random offset of variance 4. All three errors have zero mean and are mutually independent before the shared offset is added to both readings. (a) Write their covariance matrix. (b) Find the variance of their mean and difference. (c) Extend the mean variance to \(N\) independent sensor-specific errors with the same shared offset.
Track the common component once
Each reading has variance 5 and their covariance is 4. Thus the mean variance is \((5+2\cdot4+5)/4=4.5\), while difference variance is
For \(N\) readings it is \(4+1/N\) for the mean. Treating all readings as independent would instead predict \(5/N\) and would hide the calibration floor. An external calibration can address that floor.
Explore the related calculation with adjustable inputs. Change the parameters in the corresponding calculation and compare its independently recomputed values with the equation derived in this solution.
3. A line with room to test its fit
At \(x=-1,0,1\) observe \(y=0,2,1\), with independent unit-variance errors. Fit \(y=b+kx\). (a) Find the coefficients and signed residuals (observed minus fitted). (b) Compute the residual sum of squares and its degrees of freedom. (c) Compare variance of the fitted mean and variance of a future observation at \(x=2\).
Use the orthogonal design columns
The columns have squared lengths 3 and 2 and zero inner product. The intercept is the mean, 1, and the slope is \(1/2\). The fitted responses are 0.5, 1 and 1.5, leaving residuals \((-0.5,1,-0.5)\) of squared norm 1.5 and one residual degree of freedom. The coefficient covariance is diagonal with entries \(1/3,1/2\). The fitted mean at \(x=2\) has variance \(1/3+4/2=7/3\); an independent future reading there has variance \(10/3\).
Try this calculation. Change one observation’s uncertainty and recompute the weighted projection. More than one fitted coefficient requires the additional basis columns specified in this exercise.
A detector that pools two unresolved rays
A detector averages the transmitted intensities of two equally illuminated rays before reporting one reading. Each traverses 1 cm of material, with attenuation \(0.2\) and \(0.8\) cm\(^{-1}\), respectively. Compute the apparent homogeneous attenuation. Compare it with the equal-weight arithmetic mean and explain whether one pooled reading identifies the two attenuations.
Worked solution
The normalized transmitted intensities are
Their mean is \(0.634030\), so the apparent homogeneous attenuation is
Averaging the two separately measured log readings would have given \(0.5\ {\rm cm}^{-1}\).
The pooled result lies \(0.044341\ {\rm cm}^{-1}\) below the arithmetic mean. Convexity of \(e^{-x}\) explains the sign: the more transparent ray contributes disproportionately to the transmitted intensity. An infinite family of attenuation pairs has this same summed transmission. Two equal attenuations of \(0.455659\ {\rm cm}^{-1}\) provide another example.
Explore the related calculation with adjustable inputs. Rotate an omitted physical effect relative to the measured directions; treat the nonlinear pooling calculation here as an explicit source of model discrepancy.
Revisit chapter 1 · Build a ray matrix from attenuation measurements.