From first principles
Audit a recovered contrast in measurement units
Suppose two equally calibrated channels sense neighbouring state values with symmetric cross-talk \(0\le a<1/2\). Their noiseless observations are \(y_1=(1-a)x_1+ax_2\) and \(y_2=ax_1+(1-a)x_2\). Subtracting removes the common level and reveals how strongly the desired contrast \(d=x_1-x_2\) appears in the readings,
Independent zero-mean channel noise of common standard deviation \(s\) gives difference variance \(2s^2\). Inverting only this observable therefore yields the data-based estimate and uncertainty
The noise is amplified as the channels approach identical response. A useful resolution audit reports the measured difference, the calibrated contrast gain and the relevant uncertainty sources. If the gain itself is uncertain or channel noise is correlated, those effects must enter the audit before a physical contrast is claimed.
Background · Resolution matrix
For a linear regularised inverse, a row describes how the estimated parameter mixes the actual components. A sharp-looking result may still have broad resolution kernels.
Derivation and applications
Quantify signal leakage into an estimate of a local field
A reconstructed pixel is often a weighted average of several true cells. A resolution audit can predict that mixing and bound its effect using independent knowledge of admissible field gradients. Consider a linear model \(y=Ax+\epsilon\) with zero-mean measurement error of covariance \(\Sigma\), and a chosen linear estimator for the target cell \(j\), \(\widehat x_j=w^Ty\). Define its resolution weights by the response to unit signals in individual true cells,
To reproduce a uniform field exactly, require \(\sum_i k_i=1\). The bias relative to the target is then a sum of differences from that cell. Suppose independently supported spatial smoothness gives
where \(d_{ij}\) is cell distance. Taking absolute values yields
This weighted distance has units of length even when resolution weights have negative lobes. If Gaussian measurement noise is justified, a conservative two-sided interval with at least the usual 95 percent coverage for the true cell is
The bias bound is added to the statistical margin because it represents an unknown fixed error, not an independent random draw. The guarantee depends on the supplied smoothness information and calibrated forward model. At a genuine sharp interface the assumed gradient bound may be inappropriate.
Worked example
Audit a local mean on a uniform grid
Three true cell centres lie \(0.5\,\mathrm m\) apart. An estimator of the middle temperature has weights \((0.2,0.6,0.2)\), output noise deviation \(0.10\,\mathrm K\) and independently verified gradient bound \(2.0\,\mathrm{K/m}\). Its effective weighted distance is \(0.20\,\mathrm m\) and maximal mixing bias is \(0.40\,\mathrm K\). An estimate of \(18.0\,^\circ\mathrm C\) has interval half-width \(0.40+1.96(0.10)=0.596\,\mathrm K\).
Second application
Compare a sharper reconstruction at a noisy boundary
An alternative three-cell estimator has weights \((-0.1,1.2,-0.1)\) at distances \(1,0,1\,\mathrm m\). For \(L=0.50\,\mathrm{K/m}\) its bias bound is \(0.10\,\mathrm K\). With noise deviation \(0.30\,\mathrm K\), the total half-width is \(0.688\,\mathrm K\). A smoother estimator of the same target with weighted distance \(0.50\,\mathrm m\) and noise deviation \(0.12\,\mathrm K\) gives
The sharper-looking estimator yields the wider interval for this stated field class.
Set a question that can fail
Two adjacent thermal zones are blurred by the sensor matrix \(A=\left(\begin{smallmatrix}0.55&0.45\\0.45&0.55\end{smallmatrix}\right)\). Let the observations be \(y=(21.08,20.92)\) °C with independent standard deviations 0.10 K. The engineering question is whether the first zone is at least one kelvin hotter than the second. Work in mean and difference coordinates. The mean passes unchanged, while the difference is attenuated by 0.10. Before fitting, predict that uncertainty in the contrast will dominate this decision.
Derive the data-only estimate and interval
The observed mean is 21 °C, with standard deviation \(0.10/\sqrt2=0.0707\) K. The estimated true contrast is
Its standard deviation is
For known Gaussian noise, a two-sided 95% data-only interval is about \([-1.17,4.37]\) K. The inverse values \((21.8,20.2)\) exactly reproduce both readings. Nevertheless, even the sign of the contrast is uncertain at this level. The exact residual consumed both degrees of freedom and cannot test the instrument model.
Compare a prior-based inference on the same scale
Assume an independent prior for the contrast \(d\sim N(0,1\ \mathrm{K}^2)\), leaving the mean very weakly constrained. In contrast coordinates the data variance is 2 and the observed estimate is 1.60. Adding precisions gives posterior variance \(1/(1+1/2)=2/3\) K² and mean \((2/3)(1.60/2)=0.533\) K. The probability \(P(d>1\mid y)\) is \(1-\Phi[(1-0.533)/\sqrt{2/3}]\simeq0.28\). The prior changed both the centre and the width; this probability is explicitly conditional on the zero-centred prior. Repeating with a wider prior shows how much the conclusion depends on that assumption.
Buy information in the direction the decision needs
Suppose one additional test is available. Another independent repeat with the same blurred sensor reduces the data-only standard deviation of the contrast by \(\sqrt2\), to 1.0 K. A new differential sensor reading \(d+\epsilon\) with standard deviation 0.50 K and errors independent of the original instrument directly adds precision 4 K⁻² to the existing 0.5 K⁻², giving combined standard deviation \(1/\sqrt{4.5}=0.471\) K. This pre-data comparison depends on geometry and precision alone, not on an unknown future reading. Use held-back calibration objects to verify that the new sensor's stated precision and averaging model hold near an actual interface.
Communicate the final claim
Retain the observable mean and the uncertain contrast as separate reported quantities. State the noise law and model assumptions behind any interval. Where a numerical solver contributed, distinguish verified numerical precision from the statistical precision of the data. The difference is also visible in the temperature-design case: making the optimisation converge more tightly cannot restore information lost when all temperatures are close to the reference. A successful analysis may conclude that a particular observation needs redesign while still supplying an accurate prediction of another quantity.
Propagate a spatially varying calibration error
The preceding contrast calculation assumes a known blur and unbiased independent channel errors. Add two possible calibration terms: an offset \(b\) shared by both readings and a differential offset \(c\) that enters the first reading as \(+c/2\) and the second as \(-c/2\). The measurement equations then give mean reading equal to the true mean plus \(b\) and mean random error. Their difference is \(0.10d+c+e_1-e_2\). A shared offset cancels exactly from the contrast, whereas a differential offset is amplified tenfold when the contrast is reconstructed.
If the differential offset has an independently calibrated mean zero and known standard deviation \(s_c\), variance propagation gives \(\operatorname{Var}(\hat d)=(2s_e^2+s_c^2)/0.10^2\) for equal individual standard deviations \(s_e\). Treating the offset as random is appropriate for an ensemble of independently calibrated experiments with the stated calibration model. Within one installation it is a common unknown across all repeated exposures. If only a deterministic bound on \(c\) is justified, its effect is better reported as a bounded systematic displacement in addition to random sampling uncertainty.
Test the decision after averaging a hundred exposures
Suppose the original pair is observed one hundred independent times with the same differential calibration. The observed average difference remains 0.16 K, individual channel noise is 0.10 K per exposure, and calibration tests support \(|c|\le0.04\) K. The standard deviation of the averaged difference from independent channel noise alone is
In physical contrast units the random standard deviation is 0.1414 K. The possible systematic error is \(0.04/0.10=0.40\) K in either direction, undiminished by the additional exposures.
A conservative one-sided 95 percent lower limit under Gaussian independent channel noise subtracts both the worst allowed positive offset and the sampling margin. In contrast units it gives \(1.60-0.40-1.645(0.1414)\approx0.967\) K. Even with one hundred exposures this calculation falls slightly below the one-kelvin engineering threshold. Omitting the differential offset would give a lower limit about 1.367 K and reverse the decision. The discrepancy originates in the calibration model, although all raw measurements and all random-noise calculations are unchanged.
What new evidence would change the result? A reference specimen known to have zero contrast estimates \(c\) directly through the observed channel difference. If calibration tightens the guaranteed bound to 0.01 K, the same calculation gives \(1.60-0.10-0.233\approx1.267\) K. If the reference itself has uncertain contrast, propagate that uncertainty through its own blur factor before claiming the tighter bound. This comparison assigns the new measurement a clear purpose: it reduces the component of uncertainty aligned with the decision, rather than collecting more observations of a systematic offset that cancels in neither channel difference nor repeated averages.
An orientation-reversal test can also distinguish true contrast from a fixed differential channel offset. Reversing a specimen of equal geometry reverses the sign of its true contrast but preserves the channel offset. Half the difference of the two measured contrasts then isolates the blurred physical contrast, provided the specimen is stable and both orientations sample comparable regions.
Design the reversal and propagate its uncertainty
Write the normal and reversed orientation mean differences as \(D_+=0.10d+c+\epsilon_+\) and \(D_-=-0.10d+c+\epsilon_-\). Solving for the two unknowns gives
The independent information comes from changing the sign of the physical response while keeping the offset fixed. Repeating the normal orientation alone produces another row proportional to the first and cannot separate the two quantities, however many times it is repeated.
Suppose each orientation is averaged over 100 exposures with the same independent channel noise as before. The standard deviation of either orientation difference is 0.01414 K. If the two averages have independent random errors, then \(\operatorname{sd}(\hat d)=\sqrt{2}(0.01414)/0.20=0.10\) K and \(\operatorname{sd}(\hat c)=0.010\) K. With readings 0.18 K and −0.14 K, one obtains \(d=1.60\) K and \(c=0.02\) K as estimates. The one-sided lower contrast limit is \(1.60-1.645(0.10)\approx1.435\) K. Unlike the earlier bounded-offset calculation, this inference estimates the shared differential offset from the design itself.
If the specimen cools differently between orientations, or rotating it changes the sensor footprint, the two signs might no longer describe equivalent regions. A reversal carried out in alternating order across independent blocks can expose drift. Check the recovered offsets for consistency across these blocks before claiming that orientation has separated the physical contrast from an instrument artifact.
Change parameters · Explore the worked calculation