Fundamentals / Physics / Waves and optics / Optical fields, instruments and observations

Build a time lens from dispersion and a quadratic temporal phase

A temporal imaging system can stretch the time separation of two optical features without requiring them to arrive more slowly at the source. Derive the imaging condition from delay and frequency, calculate the sign of time magnification, and estimate the finite temporal aperture that limits which features can be recovered.

Derive two elementary maps in delay and frequency

Describe a narrowband wave packet by its delay \(t\) relative to a reference group and angular-frequency offset \(\Omega=\omega-\omega_0\). With Fourier convention \(A(t)\propto\int\tilde A(\Omega)e^{-i\Omega t}d\Omega\), a dispersive element contributes spectral phase \(D\Omega^2/2\). Its derivative is group delay \(D\Omega\). A narrow local time-frequency feature obeys \(t'=t+D\Omega,\ \Omega'=\Omega\). This is a shear in time-frequency space, directly analogous in algebra to propagation of a paraxial ray, but \(D\) has units of time squared and the second coordinate is angular frequency.

A time lens applies temporal phase \(+Kt^2/2\) to the envelope. With this sign convention the instantaneous angular-frequency offset is minus the derivative of envelope phase, so \(\Omega'=\Omega-Kt\) and \(t'=t\). The coefficient \(K\) has units of inverse time squared. Producing this modulation requires a physical phase-modulating or nonlinear optical process synchronised to the signal. A passive time-invariant piece of glass cannot implement an arbitrary quadratic temporal phase on an unknown incident time profile; it acts on spectrum instead.

Derive the imaging condition and track an individual feature

Place dispersion \(D_1\) before the time lens and \(D_2\) after it. Start with \((t_0,\Omega_0)\). At the lens \(t_\ell=t_0+D_1\Omega_0\); just after it \(\Omega_\ell=\Omega_0-Kt_\ell\). The output time is

\[t_{\rm out}=(1-KD_2)t_0+(D_1+D_2-KD_1D_2)\Omega_0 .\]

Sharp imaging requires the output time of an input feature to be independent of its initial frequency spread, so set \(K=D_1^{-1}+D_2^{-1}\). Then \(t_{\rm out}=Mt_0\) with magnification \(M=-D_2/D_1\). This is the finite-conjugate time-lens equation. For positive pre- and post-dispersion the magnification is negative: a later input feature appears earlier relative to the image reference. This is temporal inversion about a chosen reference delay, not propagation of information backward in laboratory time. The whole apparatus has a positive baseline transit delay common to the processed waveform.

With \(D_1=100\,{\rm ps^2}\), \(D_2=400\,{\rm ps^2}\), the required lens curvature is \(0.0125\,{\rm ps^{-2}}\) and \(M=-4\). Two pulses initially separated by \(8.0\,{\rm ps}\) emerge \(32.0\,{\rm ps}\) apart in reversed relative order. A detector having a response width of \(10\,{\rm ps}\) may now resolve the separation, provided that the optical imaging system itself supplied adequate temporal resolution. Ideal energy-conserving magnification rescales the intensity envelope by \(1/|M|\) as it stretches time, apart from losses and a possible output phase. Multiplying every time separation by four without reducing its peak intensity would create optical energy.

If the curvature is \(2\%\) below nominal,

\[K=0.01225\,{\rm ps^{-2}}.\]

Then the coefficient of \(\Omega_0\) is \(500-0.01225(40000)=10\,{\rm ps^2}\), and \(1-KD_2=-3.90\). An input spectral spread \(0.20\,{\rm rad/ps}\) contributes an output delay spread of order \(2.0\,{\rm ps}\) before other aberrations. A calibration pulse with a different spectral width can thus appear sharper even at the same imaging setting. Measure the output dependence on carrier detuning of a narrow feature to test the frequency coefficient directly.

Recover imaging from the wave integral and locate an aperture limit

The temporal propagation kernel of a quadratic spectral phase, up to constants and a uniform phase, is \(\exp[-i(t-t')^2/(2D)]\) under the adopted transform convention. In the two-propagation integral multiply the first kernel, the lens phase \(e^{iKt_\ell^2/2}\), and the second kernel. The coefficient of \(t_\ell^2\) is \((K-D_1^{-1}-D_2^{-1})/2\). At the imaging condition it vanishes. The remaining linear phase in \(t_\ell\) is \(t_\ell(t_0/D_1+t_{\rm out}/D_2)\). Integrating over an unlimited lens time produces a delta condition \(t_{\rm out}=-D_2t_0/D_1\), recovering the ray-style map directly from wave interference. Quadratic input and output phase factors remain, even where the intensity envelope is correctly imaged.

A finite flat temporal aperture of total width \(T_a\) replaces the delta condition by a sinc amplitude. For a point feature its first zero in output delay is at \(2\pi|D_2|/T_a\); referring it back to the input divides by \(|M|\), giving \(2\pi|D_1|/T_a\). With \(T_a=100\,{\rm ps}\), \(D_1=100\,{\rm ps^2}\) this input first-zero scale is \(6.28\,{\rm ps}\). A much larger time magnification cannot restore features the lens failed to collect over its temporal aperture. The criterion is a first zero of a rectangular-aperture field response; an intensity width or a Gaussian gate would use a different numerical factor.

Construct and calibrate an approximate phase profile

An electro-optic modulator driven sinusoidally can approximate a quadratic phase near an extremum. Expanding \(\Phi_0\cos(\omega_mt)\) gives a constant, \(-\Phi_0\omega_m^2t^2/2\), then a quartic term \(\Phi_0\omega_m^4t^4/24\). Choose bias phase and sign to obtain the required \(K\). The ratio of quartic to quadratic magnitude is approximately \((\omega_m t)^2/12\), so only part of the modulation period is a good lens. Widening the accepted temporal window improves nominal aperture resolution but can increase aberration in the wings. An independent phase calibration and a scan over input delays expose the tradeoff.

Distinguish magnification calibration from the image of a point

Launch two independently timed reference pulses flanking the centre of the field of view. If their input times are \(-5.0\) and \(+5.0\,{\rm ps}\), an ideal \(M=-4\) instrument places their output times at \(+20\) and \(-20\,{\rm ps}\) relative to a common delay. Their \(40\,{\rm ps}\) separation calibrates temporal magnification without requiring knowledge of an absolute cable or optical path delay. The widths of the two output features probe the point-spread response and detector resolution. A single pulse can demonstrate broadening but cannot by itself distinguish image magnification from an imperfectly focused, unmagnified pulse.

Vary \(K\) around the predicted imaging value and use two thin pulses with different carrier detunings at the same nominal time. The spread of their output positions is proportional to the frequency coefficient \(D_1+D_2-KD_1D_2\), which changes sign through best focus. Once that coefficient vanishes, repeat with inputs at different reference delays to measure \(M\). This sequence separates a focus error from a scale error. A medium with large cubic dispersion can make the zero coefficient depend on carrier detuning; sampling a third detuning diagnoses the failure of the purely quadratic matrix model.

The live phase-space calculation tracks several narrow spectral components across the device for selected input times. At the correct lens strength their output lines have equal output time at fixed input time. Detuning the lens gives them different output arrival times. Changing signs of \(D_2\) distinguishes an inverted image from one that preserves time ordering.

Tutorial on an imaging system for time

A signal traverses \(D_1=+100\,{\rm ps^2}\) and \(D_2=-200\,{\rm ps^2}\). Which lens curvature and magnification form an image?

Work through the solution

The lens condition gives

\[K=0.010-0.005=0.005\,{\rm ps^{-2}},\]

with \(M=+2\). The output keeps the ordering of features while doubling their separation. The signs refer to group-delay dispersion and temporal lens phase under the chapter's Fourier convention.

The previous positive-dispersion system images two pulses well near the centre of its time window but distorts them near the edge. Does this demonstrate a wrong constant \(D_2\)?

Work through the solution

A uniform error of the imaging condition gives residual sensitivity to input frequency throughout the window. Edge-specific distortion suggests finite gate clipping, nonquadratic temporal phase or higher-order dispersion acting on different parts of the signal. Translate the same reference pulse across the lens timing and independently sweep its carrier detuning to separate field-of-view and chromatic errors.

If the input contains a short feature at \(t_0=0\), can its optical phase always be inferred from a measured intensity image?

Work through the solution

The ideal system maps complex envelopes with known quadratic phase factors, but an intensity-only detector measures the squared magnitude. It cannot generally recover unknown input phase from that one image. A coherent reference or additional phase-diverse measurements can supply missing information. The time-lens condition guarantees a mapping of the field under ideal propagation, not complete observability of every input degree of freedom.

Kolner and Nazarathy's original paper derives temporal imaging with a time lens.

Compare selection by a finite spatial Fourier aperture with the temporal acceptance window.