Derive the coincidence baseline from two count streams
Split light on a beamsplitter and send the two outputs to separate photon-counting detectors. Write their mean count rates as \(R_1,R_2\). For stationary independent streams observed for time \(T\), the expected number of pairs in a delay bin of width \(\Delta t\) near zero is \(R_1R_2T\Delta t\) when the bin is short relative to \(T\). Each click in arm one defines a short opportunity of duration \(\Delta t\) in arm two. At long delays near the edges of a finite record, the available pair exposure is reduced; explicitly accounting for overlap time avoids a spurious triangular envelope.
The normalised second-order correlation \(g^{(2)}(\tau)\) is the measured coincidence density divided by that independent baseline. In quantum notation it uses a normally ordered intensity product, so one photon cannot register as two distinct photons at the opposite outputs of an ideal splitter. For one occupied mode at equal time,
A number state with exactly one photon has zero; a coherent field with Poisson photon statistics has one; one ideal thermal mode gives two. A low mean count rate alone implies none of these cases: attenuation lowers the count rate but independent loss ideally cancels from the normalised ratio.
For \(R_1=40\,{\rm kcounts/s}\), \(R_2=30\,{\rm kcounts/s}\), \(T=100\,{\rm s}\), and \(\Delta t=1.0\,{\rm ns}\), the expected uncorrelated baseline is 120 counts per bin. A measured 60 counts gives a raw correlation of \(0.50\). A simple Poisson estimate of the numerator uncertainty is \(\sqrt{60}/120=0.065\) before baseline, dead-time and other uncertainties. Shrinking the bin can increase temporal contrast but reduces the counts per bin, so reporting a very small \(g^{(2)}(0)\) without the actual counts or uncertainty conceals an important limitation.
Calculate the effect of uncorrelated backgrounds
In arm \(i\), let \(R_i=S_i+B_i\) with signal fraction \(\rho_i=S_i/R_i\). Assume both backgrounds are Poissonian, independent of each other and of the source, and that counting response is linear. Every coincidence involving a background contributes only its independent baseline, while true signal–signal pairs carry the nontrivial source correlation. Expanding the product gives
For equal signal fractions \(0.80\), an ideal single-emitter zero-delay dip reaches only \(0.36\) in an otherwise perfect instrument. The same background reduces a thermal single-mode peak from two to \(1.64\). A correction using \(\rho_i\) estimated at another alignment or pump power can overcorrect. Correlated background, detector crosstalk and blinking invalidate the independent-background relation or add longer-delay structures. Measure backgrounds with the relevant source and optical settings whenever possible.
A simple stationary emitter with one exponential recovery time gives
This shape can arise in a two-state incoherent pumping model because detecting an emitted photon resets the system to its ground state and the excited population recovers. A thermal bunching example has \(g_s^{(2)}=1+e^{-|\tau|/\tau_c}\) under a corresponding exponential intensity-correlation assumption. The time constant used in the latter is the intensity-correlation time; it need not equal a field-amplitude coherence time. Multi-level emitters or multimode light require a different model.
Average the correlation over the time bin
A rectangular zero-centred bin reports its mean correlation, not the instantaneous value. For the exponential departure from unity the zero-bin attenuation is \(A=(2\tau_c/\Delta t)[1-e^{-\Delta t/(2\tau_c)}]\). It tends to one for a narrow bin and approximately \(2\tau_c/\Delta t\) for a very wide one. An ideal anticorrelation with \(\tau_c=2\,{\rm ns}\), \(\Delta t=4\,{\rm ns}\) and signal fractions \(0.80\) in each arm yields
Inferring two emitters solely because the observed value exceeds one half would ignore known attenuation by both background and timing.
Electronic timing jitter gives an additional convolution with the probability distribution of the difference of the two timing errors. For independent Gaussian jitters their variances add. The measured bin width and this jitter serve distinct roles: rebinning time-tagged data cannot undo detector jitter. Extremely large bins can make single-emitter and Poisson observations nearly indistinguishable even with many total counts. A calibrated timing response and a physically justified line model can constrain an underlying time scale, but extremely narrow intrinsic features can remain unresolved.
Compare photon statistics with detector statistics
A single detector with a recovery dead time after a click produces an artificial deficit of very short same-detector intervals even for coherent light. Using separate arms avoids that particular single-detector autocorrelation artifact. Each detector's saturation can still alter measured rates, and an electronic dead time shared between channels can create a false coincidence dip. Conversely optical or electronic crosstalk can create a false peak. Send a stable coherent reference through the complete acquisition chain at comparable rates to test the baseline, and vary attenuation or cable delays to separate features tied to absolute electronics timing from those tied to optical delay.
The live graph displays an ideal recovery dip, its background-attenuated and bin-averaged counterpart, and the independent baseline. Predict the zero-bin counts by multiplying the plotted normalised value by the expected independent counts for a chosen acquisition. Increase bin width and lower signal fraction separately. Both reduce contrast, but only the finite bin averages over neighbouring delays. Measuring data with several bins from the same stored time tags tests that dependence without changing the source.
Read pulsed coincidences as areas of a peak train
A pulsed source with repetition period much longer than its emission decay produces coincidence peaks separated by that period. The central peak counts two detections attributed to the same pulse; neighbouring peaks can estimate the independent probability from different pulses. Integrate comparable windows around those peaks rather than comparing single-bin heights if jitter spreads clicks. A normalised central area of \(25\) counts against a mean adjacent area of \(100\) gives raw \(g^{(2)}(0)\simeq0.25\) under identical per-pulse brightness and efficiency. The result can coexist with obvious timing spread in every individual peak.
Slow blinking or pulse-to-pulse brightness correlation makes neighbouring peaks poor independent references. Plot several side-peak areas versus separation and compare with the mean at delays longer than the brightness correlation time. A decaying envelope in those areas contains source information that one baseline value conceals. At high detection probability, detector recovery across successive pulses can also suppress one or more nearby peaks. Vary repetition period or attenuation while keeping the binning procedure fixed to distinguish that recovery from intrinsic photon statistics.
Tutorial on coincidence data
Two equally bright independent ideal single-photon emitters contribute to one unresolved beam. Ignoring background and jitter, what zero-delay correlation follows?
Work through the solution
Each emitter cannot supply two simultaneous signal photons, while cross-emitter pairs remain possible. For \(N\) identical independent sources \(g^{(2)}(0)=1-1/N\). Two therefore give one half. If their intensities differ, the reduction is the sum of squared fractional intensities, so equal brightness is a physical assumption. Background and finite resolution can mimic a change of emitter number.
If both arms are attenuated by a factor two and the signal-to-background ratio stays fixed, how should the expected coincidence counts and normalised correlation change?
Work through the solution
The independent baseline \(R_1R_2T\Delta t\) falls by a factor four and correlated counts scale the same way for independent linear losses. Normalised \(g^{(2)}\) stays the same but counting uncertainties grow. If detector dark counts stay fixed while the signal falls, signal fractions also fall and the normalised contrast decreases.
A measured zero-delay peak gives \(g^{(2)}=1.40\) for thermal light with both signal fractions \(0.80\) and negligible timing loss. What effective number of equally populated independent thermal modes would explain it?
Work through the solution
For \(M\) independent equal modes the excess is \(1/M\). Correcting background gives \(g_s^{(2)}-1=0.40/0.64=0.625\), so \(M_{\rm eff}=1.60\). The noninteger value can represent unequally weighted modes or unresolved averaging. It is an effective contrast parameter unless the mode distribution has been established independently.
Hanbury Brown and Twiss analyse intensity fluctuations and correlations.
Connect source operation above threshold with the separate measurement of photon statistics.