Expand the wave equation in inverse optical frequency
In a transparent isotropic nonmagnetic medium, a scalar monochromatic field can satisfy \(\nabla^2 U+k_0^2n(\mathbf r)^2 U=0\), with \(k_0=2\pi/\lambda_0\). Assume \(n\) and a slowly varying envelope change over distances long compared with a local wavelength. Seek \(U=A(\mathbf r)e^{ik_0S(\mathbf r)}\). Substitution gives a leading term \(k_0^2A[n^2-|\nabla S|^2]\), a next term \(ik_0[2\nabla A\cdot\nabla S+A\nabla^2S]\), and \(\nabla^2A\). Vanishing of the leading term yields the eikonal equation \(|\nabla S|=n\). The gradient of optical path is the local normal to a phase front.
For a real leading amplitude the next term gives \(\nabla\cdot(A^2\nabla S)=0\): flux through a thin ray tube is conserved to this order. In a one-dimensional monotone geometry with rays along \(z\), \(S'=\pm n\) and the travelling-wave amplitude scales as \(n^{-1/2}\). Its field intensity parameter \(|A|^2\) falls as index rises while the transported flux proportional to \(n|A|^2\) stays constant. At an abrupt interface a reflected wave is generally needed to satisfy matching conditions, so the single-branch envelope law cannot determine the reflected power from a sudden index step.
The locally one-dimensional adiabatic criterion can be written \(|k'|/k^2\ll1\) with \(k=k_0 n\), accompanied by adequate smoothness of higher derivatives. Near a turning point the relevant longitudinal or transverse component of \(k\) can vanish even when \(n\) itself is finite. Then the WKB amplitude proportional to that component's inverse square root diverges. A finite-wave treatment gives a reflected and penetrating field. Thus merely comparing vacuum wavelength with the overall lens diameter cannot certify the ray approximation at every point.
Derive the graded-index ray equation and paraxial solution
A ray makes the optical path \(\int n\,ds\) stationary. With longitudinal axis \(z\) and transverse coordinate \(x(z)\), the integrand is \(n(x,z)\sqrt{1+x'^2}\). Its Euler–Lagrange equation is
For small slopes and a smooth index \(n(x)\simeq n_0[1-g^2x^2/2]\), retain the leading transverse restoring term. The equation becomes \(x''+g^2x=0\), with \(g\) in inverse metres. The axis has the highest index, and rays curve back toward it. Solving gives
where \(\alpha_0=x'(0)\) is the internal paraxial slope.
A full spatial pitch is \(2\pi/g\), and a quarter-pitch length \(\pi/(2g)\) transforms entrance position into angle and entrance angle into exit position. Collimated input rays with \(\alpha_0=0\) cross the axis together at a quarter pitch. Rays launched from an axial point \(x_0=0\) instead emerge parallel there since \(x'=\alpha_0\cos(gz)\) vanishes. These are reciprocal ray maps. At a flat end face outside the rod, refraction changes the external slope according to the index ratio, so an internal angle-to-position scaling should not be directly applied to the angle of an external beam without that conversion.
For \(g=200\,{\rm m^{-1}}\) and \(n_0=1.50\), the quarter-pitch length is \(7.85\,{\rm mm}\). A ray launched at \(x_0=0.40\,{\rm mm}\) parallel to the axis reaches it with slope \(-g x_0=-0.080\), compatible with a paraxial starting estimate. The assumed index depression at that entrance radius is
If a measured rod reaches only \(0.002\) depression at the same radius, either \(g\) was overstated or the parabolic model is inaccurate. An independent transverse index map and a measured pitch provide complementary checks.
Connect ray turning points to confined wave modes
For a guide uniform in \(z\), seek \(U(x,z)=u(x)e^{i\beta z}\). The scalar Helmholtz equation gives
The transverse local wave number \(k_x=\sqrt{k_0^2n^2-\beta^2}\) becomes imaginary outside the classical turning points. Away from them an oscillatory WKB mode has amplitude \(1/\sqrt{k_x}\) and phase \(\int k_x dx\); the evanescent tail decays as \(\exp[-\int |k_x|dx]\). Matching through two simple smooth turns gives the approximate condition \(\int_{x_-}^{x_+}k_xdx=(m+1/2)\pi\). The half-integer arises from the turning-point phase shifts and differs from the phase shifts at two rigid reflecting walls.
Under \(n^2(x)\simeq n_0^2(1-g^2x^2)\), the transverse equation takes harmonic-oscillator form with quadratic confinement. Direct polynomial-Gaussian normalisability yields
For small mode index relative to \(k_0n_0/g\),
Adjacent propagation constants then differ by nearly \(g\), so their relative phases refocus at \(2\pi/g\), exactly the ray pitch. A real finite core and a departure from parabolic index spoil exact equal spacing and can broaden a refocused image or pulse.
Estimate the wave scale of a smooth turning region
Near a transverse turning point \(x_t\) suppose \(k_x^2(x)\simeq-\gamma(x-x_t)\), where \(\gamma>0\) has units of inverse length cubed and the oscillatory side is \(x<x_t\). The transverse equation becomes \(u''-\gamma(x-x_t)u=0\). Rescale \(X=(x-x_t)\gamma^{1/3}\); the resulting dimensionless equation is \(u_{XX}-Xu=0\), whose decaying Airy solution matches a sinusoid with a definite quarter-phase shift on the oscillatory side. Thus the width of the turning region is \(l_t=\gamma^{-1/3}\). The wave does not reflect at an infinitely sharp geometric point, even for a perfectly smooth deterministic index profile.
If \(k_x^2\) changes by \(10^{10}\,{\rm m^{-2}}\) over \(10\,\mu{\rm m}\), the slope scale is \(10^{15}\,{\rm m^{-3}}\) and \(l_t\) is roughly \(10\,\mu{\rm m}\). A detector averaging over a larger transverse spot cannot establish the detailed penetration profile from a direct image. Increasing the index gradient makes the turning region narrower only as its inverse cube root. A ray sketch may still predict the trajectory well over millimetres while missing a micrometre-scale reflected-wave phase or modal shift. Compare the length scale of the particular observable with the turning region before replacing the local wave equation by a specular bounce.
A second reflection from a nearby turning point can overlap this Airy region. The usual two independent turning phases are then no longer justified. Solve the transverse wave equation with both sides at once or compare a matched model with the actual index profile and verify normalisable boundary conditions.
Check the paraxial assumptions against a measured ray map
Measure entrance and exit positions for several collimated beams launched at progressively larger distances from the axis. The ideal paraxial solution gives a straight line of exit versus entrance position with slope \(\cos(gL)\). Curvature in that plot can reveal aberration or departures from parabolic index. Comparing opposite launch offsets separates symmetric aberration from an off-centre guide or tilted coordinate origin.
Tutorial on a graded-index instrument
A guide with \(g=200\,{\rm m^{-1}}\) has length \(5.0\,{\rm mm}\). A ray enters at \(x_0=0.30\,{\rm mm}\) with zero internal slope. Predict its exit position and slope.
Work through the solution
The phase advance is \(gz=1.00\). Thus
The ray is still on its original side of the axis and moving inward. Treating this rod as an exact quarter-pitch element would predict a premature focus.
Using \(\lambda_0=0.60\,\mu{\rm m}\) and the example \(n_0,g\), estimate the approximate Gaussian ground-mode width scale \(w_0=(k_0n_0g)^{-1/2}\).
Work through the solution
Here \(k_0=1.047\times10^7\,{\rm m^{-1}}\), so \(w_0=17.8\,\mu{\rm m}\). The transverse field is proportional to \(\exp[-x^2/(2w_0^2)]\) in this convention. A quoted intensity \(1/e^2\) radius uses a different numerical factor. The computed width should be much smaller than the parabolic region for this ideal mode to be valid.
The ray-tube transport equation predicts unbounded amplitude at the common ray focus. Which measurement shows what the approximation omitted?
Work through the solution
Measure the finite transverse focal spot while changing wavelength and aperture. Wave diffraction limits resolution even when all geometric rays meet at one point. The leading transport approximation conserves flux as ray-tube area shrinks but cannot describe interference and phase near a caustic. A wave propagation or mode superposition through the same index map should produce a finite profile and permit a direct comparison with those measurements.
TU Delft derives optical rays and geometrical imaging.
Compare smooth index turning points with modes confined at an index jump.