Fundamentals / Physics / Waves and optics / Optical fields, instruments and observations

Measure rotation with two waves following the same path

A stationary optical loop gives equal return times for opposite propagation directions in a reciprocal medium. When the loop rotates the beams meet their starting beamsplitter at different times. Derive the measurable differential phase and compare a passive interferometer with a ring resonator.

Calculate the return times in a rotating circular loop

Take a vacuum circular loop of radius \(R\) rotating at constant angular speed \(\Omega\) in its plane, with a co-moving source, beamsplitter and receiver. In an inertial frame the receiver travels at \(v=\Omega R\). A beam propagating in the direction of rotation must catch up with the moving receiver, while the oppositely directed beam meets it early. For an ideal constrained circular optical path, \(ct_+=2\pi R+vt_+\) and \(ct_-=2\pi R-vt_-\). Thus \(t_\pm=2\pi R/(c\mp v)\), and their difference is \(4\pi Rv/(c^2-v^2)\). To first order in \(v/c\) this is \(4\Omega A/c^2\), with \(A=\pi R^2\).

The times just calculated are laboratory coordinate times. A clock on the rotating detector accumulates proper time with factor \(\sqrt{1-v^2/c^2}\); this changes the first-order result only at higher order. The local vacuum speed remains \(c\) for either beam. The effect comes from comparing their arrival at a moving part of a closed apparatus. There is no requirement to assign a different local fundamental light speed to the clockwise and anticlockwise beams.

A general co-moving loop at low rotational speed gives an extra time of flight \(d t_{\rm corr}=\mathbf v(\mathbf r)\cdot d\mathbf l/c^2\) along one orientation. Reversing orientation doubles its contribution to the difference. With \(\mathbf v=\boldsymbol\Omega\times\mathbf r\),

\[\Delta t=\frac{2}{c^2}\oint(\boldsymbol\Omega\times\mathbf r)\cdot d\mathbf l=\frac{4}{c^2}\boldsymbol\Omega\cdot\mathbf A,\]
\[\mathbf A=\frac12\oint\mathbf r\times d\mathbf l .\]

The oriented area handles tilted loops and folded paths. A figure-eight winding with two equal oppositely oriented lobes can enclose a large total unsigned area yet have zero net response to uniform rotation. Winding a fibre around the same area \(N\) times in the same orientation multiplies the directed area by \(N\).

Convert the time shift into optical phase

A continuous source of vacuum wavelength \(\lambda_0\) accumulates an optical phase difference \(\Delta\phi=\omega_0\Delta t=8\pi\boldsymbol\Omega\cdot\mathbf A/(\lambda_0c)\) at leading order. For a co-moving nondispersive dielectric loop the reciprocal static propagation time increases with index, but the standard first-order geometric Sagnac phase at a fixed external optical frequency retains this scale; applying relativistic velocity addition to propagation in the moving medium accounts for the cancellation. Flow of the medium relative to the loop, time-dependent index disturbances and nonreciprocal phase shifts can introduce additional effects.

For a hundred turns of radius \(R=0.10\,{\rm m}\), total directed area is \(3.142\,{\rm m^2}\). At \(\lambda_0=1.55\,\mu{\rm m}\) and \(\Omega=0.10\,{\rm rad/s}\) perpendicular to the loop, the time difference is only \(1.40\times10^{-17}\,{\rm s}\), yet the phase is \(0.0170\,{\rm rad}\). Direct electronic time-of-flight timing would be exceptionally demanding, while interference converts this small delay into an intensity change. Tilting the normal by \(60^\circ\) relative to rotation halves the signal and reversing the winding or rotation reverses its sign.

With equal returning intensities, a detector output can be written \(I=I_{\rm mean}[1+\mathcal V\cos(\Delta\phi+\phi_b)]\), where \(\mathcal V\) is visibility and \(\phi_b\) a controlled bias. Near \(\phi_b=0\) a small rotation changes intensity only quadratically and does not identify its sign. At quadrature, \(\phi_b=\pi/2\), the change is approximately \(-I_{\rm mean}\mathcal V\Delta\phi\). Alternating the applied bias or using both complementary outputs can reject a common power drift. A measured percentage intensity change only directly represents phase when the visibility and operating point are known.

Derive a ring resonator's beat instead of a passive phase

In an active vacuum ring laser or a tracked passive ring cavity, each propagation direction can have a separate resonant frequency satisfying an integer round-trip phase. In the simple nondispersive vacuum case let perimeter be \(P\), unperturbed time \(T=P/c\), and resonance frequency \(\nu=m/T\). A small directional time difference \(\Delta t\) gives a resonance frequency splitting of magnitude \(\Delta\nu\simeq\nu\Delta t/T=4A\Omega_\perp/(\lambda_0P)\). This readout measures a beat frequency. The passive interferometer measured a single-pass phase difference; the dimensions and perimeter dependence of the two formulas distinguish them.

A square vacuum ring of side \(1.0\,{\rm m}\) has \(A=1.0\,{\rm m^2}\), \(P=4.0\,{\rm m}\). At \(633\,{\rm nm}\) with \(\Omega_\perp=10^{-5}\,{\rm rad/s}\), the predicted directional splitting is \(15.8\,{\rm Hz}\). Double every side at fixed wavelength and angular speed: area quadruples but perimeter doubles, so the beat doubles. In a physical active ring, backscattering can couple the counterpropagating modes and produce a dead band near low rotation. A zero observed beat does not uniquely show a stationary loop unless this coupling and other bias effects have been characterised.

Estimate a rotation sensitivity from counted photons

At a balanced quadrature readout with visibility \({\cal V}\), a small phase changes the mean differential count divided by total count by roughly \({\cal V}\Delta\phi\). For independently detected photons and a shot-noise-limited balanced measurement the standard deviation of that normalised difference is approximately \(1/\sqrt N\), giving a phase uncertainty near \(1/({\cal V}\sqrt N)\). This estimate assumes the photons used in the signal actually reached the detectors and that gain mismatch, intensity noise and nonreciprocal drift do not dominate. It is a count budget, separate from the geometric scale relating phase to rotation.

For \({\cal V}=0.80\) and \(N=10^8\) detected photons the ideal phase uncertainty is \(1.25\times10^{-4}\,{\rm rad}\). The hundred-turn example then has projected-rate uncertainty about \(7.4\times10^{-4}\,{\rm rad/s}\) over that acquisition interval. Repeating statistically independent acquisitions improves the random part by the square root of their number, but cannot reduce a persistent reference bias in the same way. Rotating the coil normal through a known angle changes the physical signal as a cosine and can help identify additive biases. The calibration must use the actual normal orientation and total directed area, rather than assuming the apparatus remains level.

A longer fibre winding increases area at fixed turn radius while also increasing attenuation and susceptibility to distributed disturbances. The ideal phase scale grows with turn count; the number of detected photons and long-time noise can change at the same time. Compare those quantities independently when evaluating a different winding.

Tutorial on rejecting false rotations

What happens if a rigid loop translates at constant velocity without rotating in the first-order geometric calculation?

Work through the solution

Its velocity is constant around the path, and \(\oint\mathbf v\cdot d\mathbf l=\mathbf v\cdot\oint d\mathbf l=0\). There is no corresponding Sagnac area signal. A moving segment of a nonrigid loop can have a different line integral; the stated cancellation is for common translation of the entire closed path.

A passive interferometer with visibility \(0.80\) reports a quadrature change \(\Delta I/I_{\rm mean}=-0.0080\) for the hundred-turn geometry above. Estimate the projected rotation.

Work through the solution

At quadrature the phase change is \(0.0100\,{\rm rad}\). The example scale is \(0.170\,{\rm rad}\) of phase per radian per second, giving \(\Omega_\perp\simeq0.0589\,{\rm rad/s}\). Use the actual directed area and vacuum wavelength. A visibility correction or a bias angle error propagates directly into the rotation estimate.

Can a drifting temperature distribution mimic rotation in a geometrically reciprocal fibre loop?

Work through the solution

Two counterpropagating waves encounter a given fibre segment at different times. A static reciprocal phase shift cancels to leading order, but a changing local index can give different integrated phases on the two traversals. Compare runs with reversed physical rotation, symmetric thermal conditions and a calibrated artificial phase bias. Winding arrangement and timing of disturbances help distinguish a true oriented-area response from a transient nonreciprocal measurement error.

The Sagnac interferometer chapter hosted by Rutgers derives the phase shift of the two counterpropagating beams.

Compare a resonator's mode conditions with the directional frequency readout.