Ferromagnetic resonance from angular momentum and free-energy curvature

A uniformly magnetised thin specimen can absorb microwave power at a frequency far from the bare spin Larmor frequency. The precessing magnetic moment creates its own field. Its geometry and the anisotropy determine which restoring torques appear in the measured resonance.

Linearise the torque around the equilibrium orientation

Consider a saturated, uniformly magnetised ellipsoid with equilibrium along \(x\). Write the dimensionless unit magnetisation as \(\mathbf m\simeq(1,m_y,m_z)\). To second order use a free energy density \(F=F_0+M_s(B_y m_y^2+B_z m_z^2)/2\) with both curvature fields positive in tesla. They include bias, demagnetising fields and anisotropy. A small applied microwave field \(b_y(t)\) adds \(-M_s b_y m_y\). Define the effective field by \(-\partial F/\partial\mathbf m\) divided by \(M_s\).

\[\dot{\mathbf m}=-\gamma\,\mathbf m\times\mathbf B_{\rm eff},\]
\[\dot m_y=-\gamma B_z m_z,\]
\[\dot m_z=\gamma B_y m_y-\gamma b_y .\]

Differentiating the first equation and eliminating \(m_z\) gives \(\ddot m_y+\gamma^2B_y B_z m_y=\gamma^2 B_z b_y\). The free precession frequency is \(\omega_0=\gamma\sqrt{B_yB_z}\). The orbit generally has unequal semiaxes. In the limit of equal curvature fields the circular bare-spin result is recovered.

Obtain the thin-film frequency in an in-plane field

In a wide thin film, uniform in-plane rotation creates little demagnetising field. An out-of-plane tilt costs approximately \(\mu_0 M_s^2m_z^2/2\). A bias \(B_0\) contributes \(-M_sB_0m_x\simeq-M_sB_0+M_sB_0(m_y^2+m_z^2)/2\). Neglect crystalline anisotropy and edge corrections. Thus \(B_y=B_0\) and \(B_z=B_0+\mu_0 M_s\). With \(\gamma/(2\pi)=28\) GHz/T, \(\mu_0M_s=1.00\) T and \(B_0=0.10\) T we predict \(f_0=9.29\) GHz. Using \(28B_0\) alone would give 2.80 GHz.

Recall · Compare B-like and H-like parameters consistently

In these formulas all stiffness fields are in tesla and \(\gamma\) is in radians per second per tesla. If a field is in A/m it must first be converted where appropriate with \(\mu_0\). The static demagnetising field depends on shape as well as material.

The bare-spin straight line is recovered when the magnetisation contribution to the restoring field vanishes. An in-plane saturated film develops a curved frequency response.
The bare-spin straight line is recovered when the magnetisation contribution to the restoring field vanishes. An in-plane saturated film develops a curved frequency response.
Try it · Fmr

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Derive the absorbed-power peak and its width

Gilbert damping adds \(+\alpha\mathbf m\times\dot{\mathbf m}\) to the torque equation. To first order in small \(\alpha\) one obtains the damped denominator \(\omega_0^2-\omega^2-i\alpha\gamma(B_y+B_z)\omega\). With convention \(e^{-i\omega t}\) the average loss from a real drive of complex amplitude \(b\) is proportional to \(\omega\,\operatorname{Im}(\chi)|b|^2/2\). Near resonance the absorptive susceptibility has a Lorentzian line shape. Its angular-frequency full width at half maximum to this order is

\[\Delta\omega_{\rm FWHM}\simeq\alpha\gamma(B_y+B_z).\]

For the model film at \(B_0=0.10\) T and \(\alpha=0.010\) the frequency-swept width is about 0.336 GHz. A field-swept experiment must divide the frequency width by \(|df_0/dB_0|\) and distinguish the width of the absorption peak from a derivative peak-to-peak linewidth. Inhomogeneous fields and mode overlap broaden real lines as well.

Tutorial on extracting magnetic parameters

1 · Recover a saturation magnetisation

Work through the solution

For an in-plane film at 0.12 T, a uniform resonance at 10.0 GHz gives \(\mu_0M_s=(10/28)^2/0.12-0.12=0.943\) T in this approximation. Repeating the measurement at several fields tests the assumed geometry.

2 · Infer an intrinsic damping estimate

Work through the solution

For curvature fields 0.20 and 1.20 T and a 0.392 GHz full width, \(\alpha\simeq0.392/[28(1.40)]=0.0100\). A field-independent broadening that also contributes to the observed width would bias this single-frequency estimate upward.

3 · Explain a soft mode

Work through the solution

As one curvature approaches zero at a loss of equilibrium stability, the predicted restoring frequency approaches zero while the other curvature can remain finite. A broad or shifted low-frequency peak calls for checking domains and the validity of the uniform-magnetisation assumption.

For further study see Kittel, Introduction to Solid State Physics, 8th edition, chapters 11–13 on collective magnetic response and magnetic resonance.