Fundamentals / Physics / Thermodynamics and statistical physics / Counting, correlations and thermal measurements

Why a molecular beam and its source have different measured speeds

A tiny hole lets a dilute gas escape into a vacuum. A rotating chopper admits a short pulse and a downstream detector records arrival times. Derive the source speed density, the effusive speed density and the actual time-of-flight histogram. Each samples the same Maxwellian physics with a different weighting.

State what crosses a surface

For a gas with particle mass \(m\) and temperature \(T\), write \(a=m/(2k_BT)\). Cartesian velocity components have density proportional to \(e^{-a|\mathbf v|^2}\). Integrating over a velocity shell gives an equilibrium speed density proportional to \(v^2 e^{-av^2}\). Sampling gas particles uniformly in a volume measures this density. For particles crossing a plane aperture in unit time, a particle with normal speed \(v_z>0\) can reach the plane from a depth \(v_z\,dt\). Multiply by this flux factor and integrate over directions in the outward hemisphere. In polar coordinates about the aperture normal the angular integral of \(\cos\theta\,\sin\theta\) is independent of speed and an extra factor \(v\) remains.

\[p_{\rm gas}(v)=\frac{4a^{3/2}}{\sqrt\pi}v^2e^{-av^2},\]
\[p_{\rm beam}(v)=2a^2 v^3 e^{-av^2},\qquad v>0.\]

This model assumes a hole small compared with the molecular mean free path, negligible collisions between aperture and detector, and acceptance that selects a fixed narrow angular cone with speed-independent efficiency. A nozzle that produces an expanding collisional jet needs a different velocity distribution.

Transform speed into arrival time

Let \(L\) be the flight distance and \(t=L/v\) the transit time along the accepted direction. Probability conservation for a histogram bin requires

\[p_t(t)\,dt=p_{\rm beam}(v)|dv|.\]

The derivative \(|dv/dt|=L/t^2\) is essential:

\[p_t(t)=2a^2L^4t^{-5}e^{-aL^2/t^2}.\]

The mode of the equilibrium speeds is \(1/\sqrt a\), that of beam speeds is \(\sqrt{3/(2a)}\), and the mode of arrival times is \(L\sqrt{2a/5}\). The speed calculated as \(L/t_{\rm mode}\) is \(\sqrt{5/(2a)}\); it is neither of the speed modes. Peaks of densities are not invariant under nonlinear changes of variable. Integrated probabilities for corresponding intervals are invariant. Changing the horizontal labels on a histogram while retaining its original bin heights gives the wrong likelihood.

Fit a temperature from counted arrivals

Define thermal speed \(v_T=\sqrt{2k_BT/m}\) and time \(t_0=L/v_T\). The dimensionless variable \(s=t/t_0\) has density \(2s^{-5}e^{-1/s^2}\). An argon atom of mass \(39.95\) atomic mass units at 300 K has \(v_T\simeq353\,\mathrm{m\,s^{-1}}\). For a flight of 0.50 m the most common arrival time is about 0.895 ms; interpreting its reciprocal as the most probable gas speed would overestimate the temperature by a factor of 2.5. Finite gate width convolves the ideal distribution with the opening-time distribution. Record the gate profile or vary \(L\) to separate instrument timing from thermal spread.

Rather than fitting one maximum, consider ideal independent arrival times \(t_i\). The \(a\)-dependent part of the log likelihood is \(2N\ln a-aL^2\sum_i t_i^{-2}\). Differentiation gives

\[\hat a=2N/[L^2\sum_i t_i^{-2}].\]

Consequently \(\hat T=mL^2\sum_i t_i^{-2}/(4Nk_B)\). This estimator is just a beam-weighted mean squared speed divided by the coefficient appropriate to an effusive beam. A velocity-dependent detector efficiency would alter that coefficient.

Compare density shapes in the measurement coordinate

Change source temperature and flight length. The graph compares arrival times for particles sampled from a volume with arrivals from the effusive flux, both transformed with their correct Jacobians to equal-width time bins. Compare the most probable times and widths. Diluting an ideal gas at fixed temperature changes the signal rate, while the normalised ideal shapes stay the same. A shift of shape with pressure would suggest collisions or a change in how the source is sampled.

Tutorial

A detector records twice the flight time after doubling the path length while all dimensionless histogram quantiles coincide. Which interpretation is consistent with the data?

Work through the solution

Flight is ballistic at unchanged speed distribution. Under this model \(t_0\) scales linearly with \(L\). If a delay were dominated by an electronic timing offset it would not scale this way.

Suppose the detector efficiency is inversely proportional to speed across the relevant band. How does this affect the effusive weighting?

Work through the solution

The source flux multiplies the gas density by \(v\); the detector multiplies the result by \(1/v\). After normalisation the detected speed density has the same shape as the gas density. The time histogram still requires the Jacobian \(L/t^2\).

Why is averaging the directly transformed speeds \(L/t_i\) different from dividing flight length by the mean arrival time?

Work through the solution

The reciprocal is nonlinear. The latter is related to a harmonic mean of speeds. A broad distribution enhances the difference, even with perfect timing.

Compare a phase-space sample with a flux measurement in the kinetic theory chapter.