Write down what the instrument actually measures
Pattern a long electrode at \(z=0\) with an unknown voltage \(f(x)\), periodic over length \(L\) for this model. The region above is homogeneous, charge free, and contains a sufficiently weak probe at height \(h\). For a Fourier component \(f_m e^{ik_mx}\), \(k_m=2\pi m/L\), the bounded harmonic solution at height \(h\) is \(f_m e^{-|k_m|h}e^{ik_mx}\). Treat the constant component according to the actual reference. Suppose the probe reports an average over a rectangular window of width \(w\) centred at \(x_j\), plus noise \(e_j\). For uniform probe sensitivity the forward relation is
The exponential is physical propagation from boundary to probe; the sinc factor is averaging by the detector. The latter has exact zeros in this idealised model. For modes at those zeros no noise-free reading at the same width and height can recover the lost amplitude. More closely spaced scan positions increase the sampling bandwidth but cannot undo either such instrumental nulls or the exponential decrease of the true high-frequency signal.
A nonuniform probe shape replaces the sinc by its Fourier transform. Unknown height adds an additional calibration problem: increasing \(h\) and increasing high-frequency boundary amplitudes can yield the same readings if the amplitudes are unrestricted. Before inferring boundary detail, calibrate the probe width and decide whether height is known, measured with uncertainty or jointly estimated using an independent constraint.
A direct inverse amplifies uncertainty in predictable bands
In an ideal complete periodic scan the discrete Fourier transform separates resolvable modes. Let \(\widehat y_m=H_m f_m+\eta_m\). Inverting one coefficient gives \(f_m^{\rm dir}=\widehat y_m/H_m\) whenever \(H_m\ne0\). A perturbation \(\delta\widehat y_m\) becomes
With \(H_m=e^{-|k|h}\), the amplification grows exponentially with spatial frequency. The mode values can be uniquely determined in ideal noiseless data of infinite precision, yet the inverse is unbounded as increasingly fine modes are admitted. Finite data can additionally produce exact nonuniqueness.
For \(h=2.0\) mm and negligible aperture, boundary wavelengths 20, 10 and 4 mm have transfers \(0.533,0.285,0.0432\), respectively. With 1 mV noise in the measured amplitude of each Fourier component, inverse noise levels are \(1.87,3.51,23.1\) mV. A genuine 10 mV boundary ripple at wavelength 4 mm contributes only 0.432 mV at the probe, smaller than that noise. Plotting its raw inverted coefficient with a smooth line does not improve its information content. Reducing height to 1 mm raises that ripple's signal to 2.08 mV and changes the experiment's resolving power before any reconstruction choice is made.
Derive a regularised inverse and expose its bias
Assume coefficients are inferred separately and use a quadratic penalty. For each \(m\), minimise \(J_m=|H_m f-\widehat y_m|^2+\alpha^2 w_m^2|f|^2\) with positive weights \(w_m\) and positive regularisation parameter \(\alpha\). Splitting real and imaginary parts, or differentiating with respect to \(f^*\), gives
for zero-mean measurement noise. The reconstruction suppresses noise near a small transfer by introducing deterministic bias \( (W_m-1)f_m\). Its variance for known mode-noise variance \(s_m^2\) is \(|H_m|^2s_m^2/(|H_m|^2+\alpha^2w_m^2)^2\). Neither low variance alone nor a small data residual is evidence that a spatial ripple was recovered. Setting \(\alpha\) very large produces a smooth, nearly zero estimate regardless of the data. Setting it very small can reproduce noise almost exactly.
For \(w_m=1,\alpha=0.10\) and wavelength 4 mm in the example above, \(W_m\simeq0.157\). A true 10 mV ripple is estimated at only 1.57 mV on average. The inversion gain is about 3.64 rather than 23.1. At 20 mm, the same penalty retains 96.6% of the true amplitude. If the purpose is to quantify a short ripple, improving the experiment can be preferable to changing the penalty. A derivative penalty \(w_m\propto |k_m|\) encodes a stronger preference against fine structure; a constant mode must be handled separately if the voltage reference or the derivative penalty leaves it unconstrained.
What survives away from a uniform grid or simple geometry?
For arbitrary electrode shapes and detector positions, represent source or boundary data in a chosen basis \(f=\sum_j a_j b_j\). Solve the forward field problem for each unit coefficient and sample it exactly as the real probe would, giving matrix entries \(A_{ij}\). A noise covariance \(\Sigma\) weights the misfit through \(\|\Sigma^{-1/2}(A\mathbf a-\mathbf y)\|^2\). For an identity penalty apply the singular-value decomposition to the whitened matrix,
Each right singular vector is a source pattern; its singular value tells how strongly it appears in the whitened measurement space. Multiplication by \(U^*\) diagonalises the data misfit and reduces the problem to the scalar filters above.
A zero singular value means the chosen sensors are insensitive to an entire source combination. No choice of numerical precision or regularisation changes that observational fact. A small nonzero value means one needs sufficiently small noise and modelling errors to identify the corresponding component. A practical resolution matrix \(R=(A^*\Sigma^{-1}A+\alpha^2I)^{-1}A^*\Sigma^{-1}A\) maps a noiseless true coefficient vector to the regularised estimate. A column of \(R\) shows which neighbouring coefficients respond when one ideal source coefficient is present. Testing such impulse responses describes the reconstruction's spatial smoothing more honestly than quoting the spacing of its output grid.
Use withheld measurements and identifiable physical quantities
Reserve some independently measured positions, heights or probe widths. Fit the rest and use the recovered candidates to predict the withheld measurements by applying the forward operator. The test is more informative when the withheld observations have different sensitivity patterns. A second distant scan can verify low modes while remaining insensitive to every high-frequency ambiguity. A second close scan or a different probe width can fill modes attenuated or nulled by the first. Correlated calibration errors, such as one common voltage offset, should be modelled as such, rather than being counted as many independent observations.
A distinct nonuniqueness occurs when trying to infer an arbitrary three-dimensional charge density solely from exterior voltages. Take any smooth compactly supported potential \(g(\mathbf x)\) inside the source region whose value and derivatives vanish outside. Add \(\delta\rho=-\epsilon_0\nabla^2g\) to a candidate charge distribution. Its induced potential is \(g\) and therefore vanishes at every external detector. Unless additional sign, support or constitutive assumptions constrain the source, infinitely many internal distributions remain consistent with exact exterior data. This is stronger than amplification of measurement noise. Total charge from a closed-surface flux or low multipole moments can still be identifiable when the internal density is not.
See an ill-conditioned inverse in a two-source instrument
Two possible source patches sit symmetrically beneath two voltage probes. A calibrated forward response, in volts of probe signal per chosen source unit, is \(A=\begin{pmatrix}1&0.98\\0.98&1\end{pmatrix}\). Each patch affects both probes almost equally. The sum pattern \((1,1)/\sqrt2\) and difference pattern \((1,-1)/\sqrt2\) are orthonormal eigenvectors as well as singular vectors, with gains 1.98 and 0.02. The condition number is 99. The instrument localises total source strength much more reliably than it locates its division between the two patches.
Suppose the actual source vector is \((1,0)\). The predictions are \((1.00,0.98)\) V. A measurement perturbation \((+0.01,-0.01)\) V, though small compared with the signal, lies in the weak difference mode. The exact inverse interprets it as source error \((+0.50,-0.50)\), giving a reconstructed distribution \((1.50,-0.50)\). A common perturbation \((+0.01,+0.01)\) instead produces almost negligible source changes \(+0.00505\) each. A single rms error statistic for the voltage readings misses how their spatial correlation changes uncertainty in the reconstruction.
Use an identity Tikhonov penalty \(\alpha=0.10\). The response factors for the two true source directions become
In the absence of noise the estimated source from \((1,0)\) is approximately \((0.518,0.480)\). Both patches light up almost equally. This is the resolution matrix in action: the model predicts the observed voltages well yet cannot confidently identify which of the two patches generated them. Under the same opposite noise perturbation the additional reconstructed difference is only \(0.0192\) on each patch in opposite directions. A visually smooth result is reproducible but biased towards nearly equal strengths.
Add a third probe designed to respond as \((0.6,-0.6)\). This linear combination may be implemented physically by a differential electrode, so negative coefficients are meaningful. The squared singular gain of the old difference direction increases from \(0.0004\) to \(0.0004+2(0.6)^2=0.7204\), while the common gain is unchanged. The new difference singular value is 0.849, reducing the ratio of the largest to smallest singular values to about 2.33 if the three channels have comparable independent noise in the specified units. Adding another copy of the first common-sensitive probe would have been much less effective. Designing measurements against the weak singular vector can improve source resolution far more than collecting many redundant readings.
Separate numerical error from height uncertainty and unknown backgrounds
Return to a sinusoidal source with negligible aperture. If its true height is \(h\) but one divides by an assumed transfer computed at \(h+\delta h\), then even exact noiseless data return \(\widehat f/f=e^{|k|\delta h}\). For a 4 mm wavelength and positive height error 0.10 mm, the fractional amplitude bias is
Unlike random noise this bias does not shrink by averaging repeated scans at the same miscalibrated height. A 20 mm calibration pattern at that same error suffers only about 3.2% bias, so testing one long-wavelength standard need not guarantee short-wavelength accuracy.
For an unknown but stable boundary pattern recorded at two known relative probe heights, \(\widehat y_m(h_2)/\widehat y_m(h_1)=e^{-|k_m|(h_2-h_1)}\) for modes above noise when the aperture is unchanged. The source amplitude and common aperture factor cancel. This measures a relative vertical displacement but not the absolute height if the true boundary amplitudes are unknown. Add a calibration electrode of known voltage and wavelength, or an independently measured mechanical height, to determine the absolute scale. Near a sensor's aperture zero the ratio is exceptionally noise sensitive and should not be used for the height fit.
Consider also a slowly varying stray background produced by distant conductors. In a source-free layer of finite thickness a Fourier mode can contain both \(Ae^{-|k|z}\) and \(Be^{+|k|z}\). The growing term is excluded in a bounded half-space continued to infinity, but can represent a field launched from the upper boundary of a finite domain. For a single spatial mode measured at two heights one can solve a \(2\times2\) system for \(A,B\). Its determinant is \(2\sinh[|k|(h_2-h_1)]\), up to a sign fixed by the column order. As the two heights coalesce their rows become nearly dependent. A measurement showing unexpected height scaling may thus indicate the wrong outer boundary in the forward model rather than a faulty inverse algorithm.
A reproducible inverse analysis can be audited along three independent axes. First manufacture noise-free readings from a source whose exact forward voltage is known, then refine only the forward discretisation. Second add noise with a specified amplitude and covariance and repeat enough draws to estimate recovered variation in identified modes. Third perturb physical nuisance parameters such as probe width, height and background independently of the noise draws. For each stage state what quantity is being recovered: total charge, a few spatial coefficients, or a real-space image biased by a chosen penalty. These stages expose different error mechanisms even when they yield similar changes in a plotted voltage trace.
Build an exactly invisible internal charge perturbation
The general construction of a silent source can be made explicit for a spherical support of radius \(a\). Pick a smooth interior potential perturbation \(g(r)=V_g[1-(r/a)^2]^3\) for \(0\le r<a\), and set \(g=0\) outside. At \(r=a\) both the potential and its first radial derivative vanish; its second radial derivative also approaches zero, avoiding unmodelled surface sheets. It is regular at the origin. Therefore \(g\) itself is the potential relative to infinity of the compact charge distribution \(\delta\rho=-\epsilon_0r^{-2}d(r^2g')/dr\). With \(x=r/a\), expansion gives
The perturbation is positive near the centre and negative in an outer band if \(V_g>0\). Its enclosed charge is
It vanishes at both ends of the radius interval and is positive at intermediate radii. Gauss's law outside then gives exactly zero electric field and the chosen reference gives zero exterior voltage. A numerical inverse recovering only zero perturbation from exterior data is observationally consistent with both the absence of charge and this particular structured distribution. Integrating the polynomial with its correct \(4\pi r^2dr\) weight confirms the exact zero total charge independently.
For \(a=20\) mm, \(V_g=0.10\) V, the internal centre voltage differs by 100 mV while every ideal exterior detector, no matter how accurately calibrated, records no difference whatsoever. At \(r=a/2\), \(g=0.0422\) V and the enclosed perturbation charge is \(9.39\times10^{-14}\) C. An internal measurement can therefore break this particular ambiguity. Moving external probes closer while keeping them outside the sphere cannot. Positivity restrictions on the total density can reduce ambiguity, but adding a sufficiently small signed perturbation to a sufficiently positive background can preserve nonnegativity of both candidate densities and still leave their exterior data identical.
This example suggests a practical way to report results when full source reconstruction is impossible. Ask whether the quantity of interest changes along a silent perturbation. Total charge and all external moments stay unchanged here, whereas the central voltage and internal charge profile change. A claim about total charge can be appropriate even when detailed shell-by-shell densities are not identifiable. Conversely a fitted compact central peak may depend on the chosen smoothness penalty or positivity constraints even when every reported exterior measurement is reproduced.
A multiscale numerical exercise can demonstrate the effect reproducibly. Discretise both \(g\) and its associated \(\delta\rho\), solve the independent forward Poisson problem, and evaluate internal and external probes. Coarse grids may show a small exterior signal if source deposition fails to preserve its neutral moments. Refine the source representation, plot the exterior residual separately from the interior voltage difference and compare with the analytic polynomial. A residual that tends to zero while the interior difference remains finite is the expected physical outcome. Using exactly the same discrete operator to manufacture data and to recover them can mask representation errors, so a second mesh, an analytic source integral or a differently implemented forward solver is especially valuable.
See which part of a specimen electrodes can resolve
Compare two contact configurations and their sensitivity to a local material change. An accurate potential at the electrodes does not necessarily resolve the interior.
Can two independent estimates agree for the wrong reason?
Separate common uncertainty from independent noise in two height scans
A probe measures a 10 mm wavelength mode at heights 1.0 and 2.0 mm with negligible aperture. The two Fourier amplitudes are 5.34 and 2.85 mV, each with independent 0.10 mV random uncertainty, but they share an unknown common voltage gain. Estimate the boundary amplitude and its random error under unit gain. Decide what the agreement can establish about calibration.
Derive and check the result
The two transfers are
Each individually predicts about 10.0 mV at the boundary. For independent equal-variance amplitude noise, minimise \(\sum(y_i-H_i f)^2\). Its solution is \(f=(H_1y_1+H_2y_2)/(H_1^2+H_2^2)\), and random standard deviation \(0.10/\sqrt{H_1^2+H_2^2}=0.165\) mV. Simply averaging the two directly inverted amplitudes gives the noisier second inversion equal weight and hence a larger variance.
The measured amplitude ratio is about 0.534, as predicted by the additional 1 mm of propagation. A common multiplicative calibration factor cancels from this ratio. If the true voltage gain were 1.10, both unit-gain inversions would agree at about 10 mV even though the physical amplitude would be 9.1 mV. Repeated scans reduce the random uncertainty but cannot remove this systematic scale. A known reference electrode or independent calibrated voltage source is needed.
If instead both probes share a small additive voltage offset in every spatial sample, a full ideal Fourier analysis would place that constant entirely in the zero mode. Incomplete sampling, finite windows or background leakage can mix the offset into the fitted sinusoid. Including a constant nuisance term in a weighted least-squares fit is one way to test that effect directly. Identifying the form of a shared error is as important as quoting its magnitude: common gain, common offset and relative height uncertainty enter the inverse problem in different directions and respond to different calibration experiments.
Tutorial · compare an experimental redesign with a stronger prior
Resolve a window null without changing sample spacing
A voltage camera averages over \(w=4\) mm. A suspected boundary pattern has wavelength 4 mm. Find its measured transfer and propose a second window width that recovers sensitivity. Include the effect of a 1 mm measurement height.
Work through the solution
At equal aperture and wavelength the sinc argument is \(\pi\), giving zero. With a 2 mm window the aperture transfer becomes
Height attenuation is \(e^{-2\pi(1/4)}=0.2079\), so the combined transfer is 0.132. A 20 mV boundary amplitude therefore gives 2.65 mV in the second scan and exactly zero in the first idealised scan. Collecting more centres with the original width would still give zero. Calibrating the second aperture and its orientation is part of the forward model, especially near a sinc null where small geometry errors strongly change inference.
Choose a regularisation level by its permitted bias
For a mode with transfer 0.20 and unit penalty weight, require the mean reconstructed amplitude to retain at least 80% of the true value. Find the allowed maximum \(\alpha\). For 2 mV noise in the measured coefficient, compare inverse standard deviations with and without this penalty.
Work through the solution
Set \(W=0.04/(0.04+\alpha^2)\ge0.80\). This gives \(\alpha\le0.10\). At the limiting value the noise gain is \(0.20/(0.04+0.01)=4\), so the reconstructed noise standard deviation is 8 mV. Without regularisation the inverse noise is 10 mV. This modest improvement costs a 20% amplitude bias. The calculated tradeoff may or may not be acceptable for the physical question. Stating both numbers allows a reader to decide whether this experiment can support a claimed amplitude difference.