Designing a displacement bridge at its noise limit

A moving electrode changes two capacitances in opposite directions. Derive the displacement signal, reconstruct its noise in metres and select a carrier voltage consistent with measured mechanical stiffness and electrical losses.

Find the voltage of the moving electrode before calculating sensitivity

Consider three plane electrodes with common active area. At the centred position the middle conductor is separated by \(g\) from each outer electrode and each gap has capacitance \(C_0\). Displacement \(x\) toward the positive drive electrode reduces one gap and increases the other. Use \(s=x/g\), where \(|s|<1\). Drive the outer electrodes with coherent sinusoidal voltages \(+V_d\) and \(-V_d\), with \(V_d\) the rms amplitude of either electrode relative to ground. The middle conductor leads to a high-impedance amplifier. Its cable and input provide a fixed total capacitance \(C_p\) to ground. Leakage is initially negligible over one carrier period; the input draws negligible signal current. All formulas for carrier voltages in this project use rms amplitudes.

\[C_+=\frac{C_0}{1-s},\]
\[C_-=\frac{C_0}{1+s}.\]

The middle node has zero net charge at the carrier frequency. Its instantaneous ac charge is \(C_+(V_n-V_d)+C_-(V_n+V_d)+C_p V_n\). Set the sum to zero and solve the resulting linear equation for \(V_n\). After combining the gap capacitances the result simplifies considerably:

\[\frac{V_n}{V_d}=\frac{C_+-C_-}{C_++C_-+C_p}=\frac{2C_0s}{2C_0+C_p(1-s^2)}.\]

For zero parasitic capacitance the response is exactly \(V_d x/g\) throughout the ideal geometry. Each individual capacitance is strongly curved near an electrode. Charge conservation divides one nonlinear combination by another and removes that curvature from their voltage ratio. Additional capacitance reduces the small-signal gain and introduces an odd cubic term. Let \(\eta=2C_0/(2C_0+C_p)\). Expanding about the centre gives

\[V_n/V_d=\eta s[1+(1-\eta)s^2+\cdots].\]

The derivative at zero is \(K=\eta V_d/g\) in volts per metre. A small-signal calibration taken only at the origin implicitly accepts this cubic distortion at larger displacements.

For \(C_0=2.00\) pF, \(C_p=4.00\) pF, \(g=100\,\mu\mathrm m\) and \(V_d=1.00\) V, \(K=5000\) V/m. A displacement of 100 nm produces \(0.5000\) mV. At 20 μm, the exact signal is \(0.10204\) V against the linear prediction \(0.10000\) V. The 2.04% curvature would be apparent in a calibration over the wider range. A single proportional calibration cannot remove it. A fit to the ratio itself has a physical parameter, \(C_p/(2C_0)\), which can also be checked by measuring total input capacitance with the mechanical element held at centre.

Translate each readout fluctuation into equivalent displacement

Represent the amplifier near the carrier by an input series voltage noise density \(e_n\) and a shunt current noise density \(i_n\). With the drives treated as small-signal grounds for a noise perturbation, the central node presents \(C_T=2C_0+C_p\) at the centre. The impedance magnitude for current fluctuations is \(1/(\omega C_T)\). For mutually independent noise sources and a narrow demodulation band the corresponding input-referred displacement amplitude spectral density is

\[S_{x,e}^{1/2}=\frac{1}{K}\sqrt{e_n^2+\left(\frac{i_n}{\omega C_T}\right)^2}.\]

Use noise densities and gain referred to the same detection channel. An rms sine amplitude, a peak-amplitude display and a lock-in reading with an unreported normalisation can differ by factors involving \(\sqrt2\). Here noise figures denote the effective one-sided densities referred to the recovered rms carrier channel. For a white spectrum and an equivalent noise bandwidth \(B_e\) the displacement standard deviation equals the density times \(\sqrt{B_e}\). The displayed cut-off frequency of a multi-pole lock-in filter need not equal its equivalent noise bandwidth. A calibration using a known injected sideband measures both the gain convention and the actual band response.

At 100 kHz, \(e_n=10\,\mathrm{nV/\sqrt{Hz}}\), \(i_n=10\,\mathrm{fA/\sqrt{Hz}}\) and \(C_T=8.00\) pF, current noise produces \(1.99\,\mathrm{nV/\sqrt{Hz}}\). Adding variances gives \(10.20\,\mathrm{nV/\sqrt{Hz}}\), or \(2.04\,\mathrm{pm/\sqrt{Hz}}\) at the stated gain. A 100 Hz equivalent noise bandwidth gives 20.4 pm rms of electrical readout noise. Cable capacitance reduces the voltage made by current noise but also reduces signal gain. In fact \(C_T K=2C_0 V_d/g\), so their ratio for current noise is independent of \(C_p\) in this model. The voltage-noise contribution grows with cable capacitance. Higher carrier frequency initially reduces the current contribution but reaches a plateau set by voltage noise.

Derive backaction for a floating sensing plate

Electrical drive can change the mechanical stiffness of the sensor. For each gap take half the squared rms gap voltage times its capacitance derivative. This follows either by averaging the instantaneous plate pressure over a carrier cycle or by differentiating electrical coenergy with the middle node at its charge-balanced voltage. Mechanical motion must be slow compared with the carrier. Since \(C_-'\) is negative, the two signed forces cancel at the centre. For a small positive \(s\), write \(V_n\simeq\eta V_ds\),

\[C_+'\simeq(C_0/g)(1+2s),\]
\[C_-'\simeq-(C_0/g)(1-2s).\]

The leading imbalance is

\[F=\tfrac12 C_+'(V_d-V_n)^2+\tfrac12 C_-'(-V_d-V_n)^2\simeq\frac{2C_0 V_d^2}{g^2}(1-\eta)x .\]

The electromagnetic stiffness \(K_e=2C_0 V_d^2(1-\eta)/g^2\) subtracts from the mechanical restoring stiffness \(k\). If \(C_p=0\), the equal field magnitudes on both sides cancel exactly for every displacement in ideal plane geometry. To check directly, the positive gap field is

\[[V_d(1-s)]/[g(1-s)]=V_d/g.\]

The negative gap field has the same magnitude. A charge amplifier holding the central electrode at virtual ground would change this condition and have a different backaction; its calibration must use its own circuit. For a finite \(C_p\), the measured change of resonance with carrier voltage can identify electrical coupling independently of the signal voltage.

With \(k=0.020\) N/m the nominal configuration has \(K_e=0.00020\,\mathrm{N/m}\) at 1 V and \(0.00080\,\mathrm{N/m}\) at 2 V. At 2 V the resonance ratio for the same effective mass is

\[\sqrt{1-0.0008/0.020}=0.980.\]

A 2% frequency decrease measures roughly a 4% reduction of stiffness. If the displacement is imposed by a very stiff external positioner this effect changes the force needed to hold position. If the sample is itself a force sensor, the same effect changes the mechanical conversion between applied force and displacement. Quoting an electronic noise floor without specifying which mechanical situation is intended can hide the larger uncertainty.

Choose a feasible drive and include Brownian motion

Raising the carrier at fixed frequency increases displacement signal. It may also heat the dielectrics, exceed amplifier headroom or significantly soften the spring. Suppose each gap at centre has an effective loss tangent \(\tan\delta\), with a real conductance \(\omega C_0\tan\delta\) at the carrier. Its dissipated power is conductance times the squared rms voltage. Add both gaps to find

\[P=2\omega C_0\tan\delta V_d^2.\]

Fixed parasitic capacitance at the stationary middle node has negligible carrier voltage at exact balance in this model. An actual shield or cable dielectric connected directly to one of the drive nodes will have its own loss. A calorimetric or current phase measurement should include that extra load.

With effective \(\tan\delta=0.010\), the two active gaps dissipate 25.13 nW per squared volt at 100 kHz. A 100 nW heat budget gives \(V_d\le1.995\) V. A driver that remains linear to 2.50 V and a softening allowance \(K_e\le0.1k\) permit 2.50 V and 3.16 V respectively. The thermal bound sets the largest practical drive under these assumptions. For the electrical readout alone, the best feasible setting is thus 1.995 V and the electrical floor is about \(1.02\,\mathrm{pm/\sqrt{Hz}}\). A separate limit on the electric field or measurement amplitude could be introduced as another experimentally justified constraint.

Now let the mechanical element have viscous damping \(b=1.00\times10^{-6}\,\mathrm{N\,s/m}\) at \(T=300\) K. In thermal equilibrium the one-sided Brownian force density is

\[\sqrt{4k_BT b}=1.29\times10^{-13}\,\mathrm{N/\sqrt{Hz}}.\]

Far below mechanical resonance its displacement density is this force divided by \(k-K_e\). At 1 V it is \(6.50\,\mathrm{pm/\sqrt{Hz}}\), already greater than the electrical term. At 1.995 V it is about \(6.70\,\mathrm{pm/\sqrt{Hz}}\). The combined density adds in quadrature, giving about 6.81 at 1 V and 6.78 at the heat limit. A minimum of the total can occur between them. For an imposed position of a rigid stage the Brownian motion of this compliant probe may be outside the measurement model; for a freely suspended sensing mass it is part of the signal uncertainty. The optimisation criterion follows the physical quantity the instrument measures.

Use the phase and polarity of a calibration to track false signals

Middle-node leakage to ground with conductance \(G\) changes the circuit equation to \([G+i\omega C_T]V_n=i\omega(C_+-C_-)V_d\) at small displacement. The ideal gain acquires a factor \(i\omega C_T/(G+i\omega C_T)\). For a 10 MΩ leakage path and 8 pF, the corner is 1.99 kHz. At 100 kHz the magnitude reduction is about 0.02% and the phase lead about \(1.14^\circ\). At 2 kHz both quadratures matter. A drift in humidity that lowers the resistance can look like a gain change if only the in-phase channel is recorded. Measure a known displacement at two carrier frequencies and fit both quadratures before interpreting it as a change in geometry.

Suppose the two actual drives are \(V_d(1+a)\) and \(-V_d(1-a)\). At centre the output becomes \(\eta V_da\), equivalent in the small-signal calibration to displacement \(ag\). An amplitude imbalance of one part in ten thousand gives a 10 nm offset at \(g=100\,\mu\mathrm m\), many orders above a short-band noise floor expressed in picometres. Reverse the mechanical calibration displacement to isolate odd signal, measure the voltages at the electrode terminals and compare the nulled bridge under exchange of the drive channels. Reversing both carrier phases simply reverses both desired signal and this coherently driven offset; by itself it cannot distinguish them. An offset stable over a short scan can be estimated from two symmetric calibration displacements, whereas a drifting imbalance requires a reference or simultaneous drive measurement.

Find the minimum for a compliant probe instead of guessing at it

It is possible to optimise the free probe analytically up to a scalar root. Write \(y=V_d^2\), \(K_e=hy\), and \(a\) for the readout displacement density at unit drive multiplied by one volt. Let \(d_F=\sqrt{4k_BT b}\) be the Brownian force density. At displacement frequencies well below the resonance, the total variance density has an electrical term falling as \(1/y\) and a mechanical term that grows as the spring softens:

\[S_x(y)=\frac{a^2}{y}+\frac{d_F^2}{(k-hy)^2},\]
\[{dS_x\over dy}=-{a^2\over y^2}+{2h d_F^2\over(k-hy)^3}.\]

On the stable interval the first derivative strictly increases when \(h>0\). The first term starts at negative infinity and the second diverges at the stiffness boundary. Hence there is one unconstrained minimum. Solve a bracketed scalar equation for \(y\), then compare with each experimental upper bound in volts squared. At zero parasitic capacitance the ideal floating plate has \(h=0\); total noise then falls monotonically toward an asymptotic Brownian floor. A numerical routine that divides by \(h\) would fail precisely at this informative physical limit. In either case, a force-noise specification referred to the external sample can produce a different optimum because force conversion multiplies displacement noise by stiffness.

With the baseline values \(a=2.039\times10^{-12}\ \mathrm{m\,V/\sqrt{Hz}}\), \(h=2.00\times10^{-4}\ \mathrm{N/(m\,V^2)}\), \(d_F\simeq1.287\times10^{-13}\ \mathrm{N/\sqrt{Hz}}\). Substitution brackets the stationary point between 1.45 and 1.50 V. At roughly 1.47 V the density is about \(6.72\,\mathrm{pm/\sqrt{Hz}}\), a shallow minimum compared with the heat-limited result. A tiny uncertainty in amplifier noise or in the support damping could shift the exact optimum appreciably while having very little effect on achievable resolution. Reporting a numerically optimised voltage to six decimals would imply a knowledge of the physical system absent from these inputs.

A direct bench experiment can test whether the excess really comes from compliance. Compare the demodulated spectrum with the centre plate tightly held and with it free. The electrical floor should be similar if the clamping keeps cable capacitance and carrier coupling fixed. The free probe should acquire a mechanical resonance which moves with \(V_d^2\), and the low-frequency component should track the inferred static stiffness. A large peak locked to carrier-drive amplitude modulation in both experiments suggests coherent feedthrough. Also check that the noise estimate comes from a frequency band above drift yet below resonance, and that the inferred amplitude density times the square root of the bandwidth predicts repeated stationary readings. These practical checks distinguish a readout-limited displacement estimate from a calibrated measurement of actual thermal motion.

Explore the usable voltage range of the bridge

The horizontal axis ends at the first of the heat, driver and mechanical limits. With 4 pF fixed parasitic capacitance at 100 kHz the heat ceiling is 1.995 V rms, while a freely suspended probe reaches its minimum combined noise near 1.47 V rms. Reduce the added capacitance to zero and explain why a finite optimum arising from mechanical softening disappears. Then lower carrier frequency. The current-noise term grows and dielectric heating at a given voltage falls. Observe which effect changes the allowed voltage range and which changes the height of the electrical noise curve.

Tutorial · separate electronic resolution from mechanical response

Find the frequency at which current and voltage noise contribute equally

Retain the baseline input capacitances and noise sources. Calculate the crossover frequency and the effect of doubling cable capacitance from 4 pF to 8 pF. What happens to input-referred current-noise displacement at fixed frequency?

Work through the solution

Set \(i_n/(2\pi f C_T)=e_n\). With \(C_T=8\) pF the crossover is \(19.9\) kHz. The longer cable gives \(C_T=12\) pF and a crossover at 13.3 kHz. At 100 kHz, the current noise at the input falls to \(1.33\,\mathrm{nV/\sqrt{Hz}}\) but gain falls from 5000 to 3333 V/m. The current contribution remains \(0.398\,\mathrm{pm/\sqrt{Hz}}\). The voltage contribution increases from 2.00 to 3.00 pm/√Hz. Both results follow independently by substituting \(K=2C_0V_d/(g C_T)\) into the noise formula and cancelling \(C_T\) in only one of the two terms.

Diagnose a frequency shift and a noise claim

At 2.00 V the resonance changes from 500.0 Hz to 490.0 Hz. Determine the implied stiffness reduction. A second experiment quotes 10 pm rms in a 100 Hz noise bandwidth for the freely suspended probe at 300 K. Can thermal equilibrium and the measured spring and damping account for this number?

Work through the solution

At unchanged moving mass \(k_{\rm eff}/k=(490/500)^2=0.9604\). The measured electrical stiffness is \(0.000792\) N/m, consistent with the 0.00080 N/m prediction. At frequencies well below resonance the Brownian density is approximately 6.70 pm/√Hz, and a flat 100 Hz equivalent band would contain approximately 67 pm rms of thermal motion alone. Ten picometres rms would correspond to about 2.2 Hz equivalent noise bandwidth at this density, or require a changed mechanical condition, frequency band or calibration. To discriminate experimentally, measure the mechanical resonance spectrum with a known input-force calibration and integrate the noise with the actual filter transfer. Include mechanical susceptibility over the band if the filter extends close to resonance.

Further reading