Reduce a three-dimensional field to a capacitance gradient
A light insulating strip is attached to a translation stage by a spring. Two stationary metal plates extend a length \(L\) in the direction of motion and have width \(w\) and separation \(d\). The leading face of the strip is at coordinate \(x\), measured from the entrance to the plates. The strip is longer than the active length, has thickness \(t<d\), and fills the width in the interior to good approximation. The combined air clearance above and below it is \(d-t\). Use \(V\) for the terminal voltage and increasing \(x\) for insertion. Electrode lengths and widths appreciably exceed the gap. Which information about the detailed electrostatic field is needed to predict a force in the horizontal direction?
First consider one square metre of plate well inside the overlap region. A pillbox straddling an air–solid interface contains no free charge, so the normal displacement \(D\) has the same value in air and solid. The fields are \(D/\epsilon_0\) and \(D/(\epsilon_0\epsilon_r)\). Integrating the field through the layers gives the series law per unit area. Another square metre outside the strip has the gap filled entirely with air.
Adjacent columns share the same voltage. For a small interior displacement \(dx\), area \(w\,dx\) changes from the air value to the filled value. Thus \(dC=w(c_f-c_a)\,dx\). Define \(K=w(c_f-c_a)\), measured in farads per metre. For a rigid straight edge well inside the plates it is nearly constant. Any fixed capacitance from leads adds to the measured \(C\) and drops out of \(K\). Guard electrodes, if fitted, must be included in the electrical boundary conditions. Moving the guard or measuring a different pair of terminals can change the gradient itself.
For \(L=30\) mm, \(w=20\) mm, \(d=0.50\) mm, \(t=0.40\) mm and \(\epsilon_r=4.0\), the series thickness is 0.20 mm. The effective relative permittivity of a filled column is 2.50. The ideal empty capacitance is 10.63 pF and the filled capacitance is 26.56 pF. The slope is \(0.5313\) pF/mm. A naive average of permittivity by volume gives 3.4 and overestimates the force. It would apply to columns side by side in a uniform tangential field. The orientation of the interface supplies the missing piece of information.
Account for the power supply during a displacement
Imagine changing \(x\) very slowly at fixed voltage. The source transfers \(dQ=V\,dC\) through voltage \(V\), supplying \(V^2dC\). The energy in the field increases by \(\tfrac12V^2dC\). Their difference is the mechanical work \(F\,dx\) delivered to the moving strip. For an electrically isolated pair, \(Q\) is constant and energy \(Q^2/(2C)\) decreases with increasing insertion. Differentiating either description gives
Their instantaneous values agree when \(Q=C(x)V\). Their evolution after a displacement generally differs. At 80 V the plateau force is \(1.700\,\mu\mathrm N\). A spring of \(0.20\,\mathrm{N/m}\) allows an extra \(8.50\,\mu\mathrm m\) of insertion if the slope stays constant. The source supplies \(102.0\) nJ over a complete ideal 30 mm sweep. Mechanical work is \(51.0\) nJ and the field gains \(51.0\) nJ. Make this independent check by evaluating each endpoint energy separately. With the charge prepared on empty plates then disconnected, the final voltage is
The final plateau force approached from the interior falls to \(0.272\,\mu\mathrm N\). Once the slab is fully inside, the edge term makes the force decay toward zero.
How can a vertical field pull a slab horizontally? Deep in either uniform column the local translational symmetry prevents a longitudinal push on a uniform piece of material. There is a transition near boundaries where the field curves and the polarisation changes. The work calculation moves material through this transition while keeping the remote uniform regions trackable. It predicts the integral of the force without locating each contribution. A force calculation based only on a vertical component times a horizontal normal lacks the tangential and normal stress components on a closed surface. Evaluating a vacuum Maxwell-stress integral on a contour around a finite strip gives a physically independent check of the net result when the supporting mechanical contact is accounted for separately.
Infer an edge profile from a measured trace
An abrupt switch in \(C'\) at the end of a plate would imply an unlimited second derivative. There is a finite interaction length around any real edge. A convenient interpolation for fitting data starts from the ideal rectangular overlap derivative and smooths each step over a length \(\ell\). Take the measured empty capacitance, including any fixed wiring, to be \(C_b\). A symmetric fit for the measured gradient and its integral is
At large negative \(x\) the bracket tends to zero, at large positive \(x\) it tends to \(2L\). The area under the gradient therefore produces the correct total increment \(KL\) for every \(\ell\). This normalisation is important. A fit that reproduces the centre of each transition but changes the area also changes the predicted work in a complete insertion. The two edges can have different widths near asymmetric supports. A fit should then keep the capacitance endpoints and the physical separation of the stations as independent experimental checks.
For \(L\gg\ell\) the first isolated transition reaches 10% and 90% at \(x/\ell=\mp\operatorname{atanh}(0.8)\). Their separation is \(2.1972\ell\). An observed 1.10 mm separation implies \(\ell=0.501\) mm. At the entrance the voltage-controlled gradient of force is
the spring sees \(k_{\rm eff}=k-F'_V\). At the exit the slope reverses and the oscillation frequency increases. For the numerical stage the entrance subtracts \(0.00170\) N/m from its \(0.20\) N/m spring. The ratio of loaded to zero-bias resonance frequencies is about 0.9957, if the moving mass is unchanged. The middle of the strip gives the largest static displacement but essentially no frequency shift under ideal voltage control. Measuring displacement and frequency at the same point distinguishes a force from a force gradient.
Estimate a derivative with enough resolution to trust its sign
A bridge returns \(C\) at positions separated by a calibrated step \(h\). For the central derivative \(D_h=[C(x+h)-C(x-h)]/(2h)\), expansion of both observations about their midpoint gives
With independent capacitance noise of standard deviation \(s_C\) per reading, the standard deviation of the slope is \(s_C/(\sqrt2h)\). Shrinking \(h\) reduces truncation bias but magnifies random fluctuations. This competition reverses the familiar intuition that the smallest encoder step necessarily gives the most accurate force. A slowly drifting bridge offset can cancel between close readings, whereas a drift proportional to time can imitate a slope if all positions are visited in only one direction.
Suppose each measurement has 0.005 pF rms noise and \(h=0.25\) mm. The slope noise is 0.0141 pF/mm, 2.7% of the plateau. At fixed 80 V this corresponds to 45 nN rms in a single force estimate. Twenty-five independent pairs bring this contribution down to 9 nN. An uncertainty of 0.5% in voltage causes a 1% scale uncertainty in force shared by all the pairs. Repeated measurement cannot cancel a common scale uncertainty. At the exact centre of an isolated symmetric edge the symmetric difference of the integrated profile returns exactly \(K/2\): opposite gradient values sum to \(K\). The surrounding curve can still suffer marked smoothing. A correct midpoint alone provides a weak validation of a fitted transition length.
A complementary measurement clamps the stage at positions separated by several millimetres and obtains the force from a calibrated spring deflection. Fit the measured forces against \(V^2\) at each position with an intercept free to capture a mechanical preload. A force caused by a contact potential \(V_c\) would instead have its parabola centred at \(V=V_c\). Measurements of both voltage polarities reveal this offset; a single magnitude and a zero point cannot distinguish it from a biased slope. Perform both insertion and withdrawal sweeps. Hysteresis in the measured spring position with almost identical \(C(x)\) indicates mechanical friction or creep rather than a change of the electrostatic energy law.
From a fitted edge to a field calculation
A two-dimensional cross-section can test which part of the interpolation is determined by geometry. In the air and in the strip solve \(\nabla\cdot(\epsilon\nabla\phi)=0\). Prescribe metal potentials, extend the exterior region far enough to include fringing field and match continuous potential and normal displacement at each material boundary. At each \(x\), calculate \(C(x)\) in two independent ways. Integrate the normal displacement on the driven electrode to get \(Q/V\). Integrate \(\epsilon|\nabla\phi|^2\) over every dielectric region and divide by \(V^2\) to get the energy definition of capacitance. Both quantities per unit width must be multiplied by the same model width. Integrating only over the material strip removes the energy of the air gap, precisely the storage mechanism that reduced the effective permittivity.
To find force by differentiating numerical energies, use the same domain, mesh quality and quadrature on displacements either side of the evaluation point. A remeshing error uncorrelated from point to point enters like the measurement noise in the preceding calculation. Vary the displacement step and repeat with a finer mesh. A range of steps where the force moves little under both changes is stronger evidence than obtaining a smooth potential plot. Resolve thin clearance layers explicitly or represent them using a validated thin-layer boundary condition. Test the sharp-edge idealisation by changing the radius of the metal edge. The integrated force can converge even while a pointwise maximum field remains sensitive to this radius.
Finally, ask which geometric parameters can be determined from the plateau. Its single slope measures \(d-t+t/\epsilon_r\) if \(w\) and \(d\) are known. It cannot separately determine thickness and relative permittivity. The electrical endpoint change provides \(KL\), which is the same measurement multiplied by \(L\); including both in a fit as independent material constraints can produce an artificially small confidence interval. Measuring \(t\) mechanically, or repeating with material samples of independently known thickness, resolves the ambiguity. The observed edge widths provide other geometric information but require a field model of the support and nearby shields before they can be interpreted as a direct permittivity measurement.
Measure curvature with a small carrier modulation
Capacitance-gradient force can be checked while a stage is held near a prescribed operating position. Bias the plates at \(V_0\) and add a small sinusoidal voltage \(v\cos\omega t\), where \(v\) is a peak amplitude in this experiment. With the stage almost stationary, expand the square of this voltage. The constant force is \(C'(V_0^2/2+v^2/4)\), the force at \(\omega\) has peak amplitude \(C'V_0v\), and the force at \(2\omega\) has amplitude \(C'v^2/4\). The latter persists at zero dc bias. Reversing the bias reverses the first harmonic while leaving the second harmonic unchanged. These are experimentally separable predictions of the local energy law even if the absolute mechanical preload is poorly known.
On the plateau of the example, choose \(V_0=40.0\) V and \(v=2.0\) V. The first-harmonic force is 42.5 nN and the second-harmonic force is 0.531 nN. Well below mechanical resonance a 0.20 N/m spring turns these into peak oscillations of 0.213 μm and 2.66 nm. Close to resonance the spring response instead multiplies each force by its own complex susceptibility at \(\omega\) or \(2\omega\). A measured ratio of displacement harmonics should therefore be divided by the ratio of those susceptibilities before attributing any difference to dielectric nonlinearity. Sweep the modulation frequency slightly or use a mechanical shaker calibration to measure the transfer function independently.
One subtle source of false harmonics is the motion itself. Near the entrance \(C'\) changes over a distance of order \(\ell\). A vibration that appreciably samples this length modulates the force even at constant bias. To use the harmonic test above, verify that the measured oscillation is small compared with \(\ell\) and that any mean position shift due to bias has been accounted for. On withdrawing the dielectric entirely, both force harmonics should tend to the background associated with moving cables or the support. This empty-stage control tests the often implicit assumption that the wire capacitance is independent of stage position. A fixed added cable capacitance changes a charge-controlled experiment, but only a position-dependent contribution can imitate a capacitance gradient at fixed voltage.
Compare a connected and an isolated moving strip
Follow the leading edge from outside the plates to beyond the exit. In the connected experiment the interior pull stays near 1.70 μN at 80 V. In the isolated experiment the charge is prepared at half insertion and kept fixed; no extra cable capacitance is included here. Find the common point of the two curves, then increase the fitted transition length. The peak displacement derivative of force changes even though the integrated voltage-controlled work over a complete traversal remains the same. Predict the sign of the resonance shift on each side of the device.
Tutorial · infer a material property and test the energy balance
Recover a clearance and assign an uncertainty
The plateau is \(0.500\pm0.015\) pF/mm. Width and plate separation retain their nominal values; a mechanical gauge gives \(t=0.400\) mm. What permittivity follows? If instead \(\epsilon_r=4\) is accepted, what total clearance follows?
Work through the solution
Calculate the equivalent thickness from \(d_e^{-1}=d^{-1}+K/(\epsilon_0 w)\). The observed \(K\) gives \(d_e=0.2073\) mm. With known thickness,
Differentiation gives \(|\delta d_e|=d_e^2|\delta K|/(\epsilon_0w)=0.00364\) mm, corresponding to approximately 0.13 in relative permittivity with other quantities held fixed. A positive fluctuation of slope gives smaller equivalent thickness and larger inferred permittivity.
With known permittivity and unknown clearance \(a=d-t\), write \(d_e=a+(d-a)/4\). Then \(a=(4d_e-d)/3=0.1097\) mm, with uncertainty 0.0049 mm. Substitution into the original series expression reproduces the observed slope. These two inferences answer different experimental questions. The same pair of endpoints cannot establish both estimates simultaneously without the extra information specified in each part.
Compare two preparations over one short motion
At half insertion connect 80 V, then isolate the terminals including 5.00 pF of fixed wiring. Use the ideal interior geometry. Estimate force after a further 5.00 mm motion and calculate the released mechanical work directly from endpoint energies.
Work through the solution
The initial total capacitance is \(10.63+7.97+5.00=23.60\) pF, so \(Q\simeq1.888\) nC. The final value is \(26.25\) pF and the terminal voltage falls to \(71.9\) V. The final force is \(1.37\,\mu\mathrm N\). The energy released is \(Q^2(1/C_i-1/C_f)/2\simeq7.65\) nJ. Independently integrate \(Q^2K/[2(C_i+Kx)^2]\) over the 5 mm path. The antiderivative is \(-Q^2/[2(C_i+Kx)]\) and gives the same result. The mean force of \(1.53\,\mu\mathrm N\) lies between the initial 1.70 and the final 1.37. Leaving the wiring out of this calculation leaves the voltage-controlled plateau unchanged but predicts an incorrect final voltage and energy release in isolation.