Fundamentals / Physics / Electrodynamics / Notebooks

Can two ohmic layers imitate a relaxing dielectric?

Model a film and its contact layer in series. Derive the frequency scale of interfacial charge accumulation and decide which features of a measured spectrum can arise from geometry alone.

Try it · Leaky layers

Change the inputs and compare the recalculated curves with the preceding derivation and baseline figure. The axes give the units; the numerical readout states the model assumptions and any limiting cases. Reset the inputs to return to the reference setting.

Download the corresponding editable notebook. The browser recalculates the reduced equations directly; the notebook exposes the full calculation and its checks.

Save notebook (.ipynb)

Python runs on this device. The first run loads the scientific libraries.

Match total current at a leaky interface

Take harmonic fields proportional to \(e^{i\omega t}\). In layer \(j\), Ohm's law and Maxwell's displacement current give \(J=Y_j E_j\) with \(Y_j=\sigma_j+i\omega\epsilon_j\). Use absolute permittivity in SI units. Total current is continuous across the interface. If the first layer occupies thickness fraction \(f\), the imposed mean field is

\[\bar E=fE_1+(1-f)E_2.\]

Eliminating the layer fields yields

\[Y_{\rm eff}=\frac{Y_1Y_2}{fY_2+(1-f)Y_1},\]
\[\tau=\frac{f\epsilon_2+(1-f)\epsilon_1}{f\sigma_2+(1-f)\sigma_1}.\]

The denominator is proportional to \(1+i\omega\tau\). A pole has appeared even though each material has frequency-independent conductivity and permittivity. The free interfacial charge per unit area is \(\epsilon_2 E_2-\epsilon_1 E_1\) with the normal from layer 1 to layer 2. At low frequency the less conducting layer takes a larger field. At high frequency the displacement currents determine the field sharing.

Separate dielectric storage from direct conduction

Infer the relative storage permittivity as \(\operatorname{Im}(Y_{\rm eff})/(\omega\epsilon_0)\). A DC current is real and drops out of this quantity. For layers with the same relative permittivity, their high-frequency effective value must equal that common value. In the DC limit the effective conductivity is the thickness-weighted harmonic mean. These two checks are independent. The interface can nevertheless produce a large rise in apparent storage on the low-frequency side. Use a first layer that fills 20% of the gap and has conductivity \(10^{-8}\) S/m. Give the other layer conductivity \(10^{-6}\) S/m and both layers relative permittivity 4. The DC conductivity is \(4.81\times10^{-8}\) S/m. An applied mean field of 1000 V/m therefore drives \(4.81\times10^{-5}\) A/m². The weakly conducting layer needs about 4808 V/m to carry it and the second layer only 48.1 V/m. Their thickness-weighted mean recovers the imposed field.

The time constant is 0.170 ms, corresponding to 935 Hz. Expanding the two complex conductivities to first order in frequency gives the low-frequency relative storage permittivity

\[4[f\sigma_2^2+(1-f)\sigma_1^2]/[f\sigma_2+(1-f)\sigma_1]^2=18.50.\]

At high frequency it falls to 4. Make the conductivities equal in the notebook and predict the interfacial charge before running it. The denominator still defines a time scale algebraically but its pole cancels out of the measured admittance.

Set the experimental inputs

Edit these values, then run the calculation and both figures again.

Use the measured transition frequency and a thickness series to distinguish interfacial storage from an intrinsic molecular relaxation.

Each curve is an amplitude. Add the complex fields with their phases before checking that the thickness-weighted average equals the applied field.

Exercise · remove the relaxation

Which choice of layer properties makes the interfacial charge vanish for every frequency?

The charge vanishes if \(\epsilon_2/Y_2=\epsilon_1/Y_1\). The imaginary terms cancel identically after cross multiplication, leaving \(\epsilon_2\sigma_1=\epsilon_1\sigma_2\). The two dielectric relaxation times are then equal. Check the limit by making both layers identical.

Exercise · exchange the materials

Relabel the layers and their thickness fractions. Which measurements can distinguish the order of this stack?

The two-terminal admittance is unchanged under \((1,2,f)\mapsto(2,1,1-f)\). It cannot identify which material is nearer the upper electrode. A local field measurement at a known depth or a contact-specific measurement can distinguish the configurations.