Average a phase associated with a fluctuating position
Let an atom have position \(\mathbf R+\mathbf u\), where \(\mathbf R\) is its mean position and \(\langle\mathbf u\rangle=0\). At momentum transfer \(\mathbf Q\), the coherent elastic amplitude is proportional to \(e^{i\mathbf Q\cdot\mathbf R}\langle e^{i\mathbf Q\cdot\mathbf u}\rangle\). For a Gaussian displacement distribution with covariance \(U_{ij}=\langle u_i u_j\rangle\), the scalar \(X=\mathbf Q\cdot\mathbf u\) is Gaussian with zero mean and variance \(Q_iU_{ij}Q_j\). Completing the square in its characteristic-function integral gives
Thus the amplitude is multiplied by \(e^{-Q_iU_{ij}Q_j/2}\); its coherent Bragg intensity receives the factor \(e^{-Q_iU_{ij}Q_j}\) for equivalent atoms. Writing amplitude and intensity separately avoids the common factor of two error.
For isotropic motion the mean square displacement along one specified axis is \(U\), with total three-dimensional mean square displacement \(3U\). The intensity factor is \(e^{-Q^2U}\), not \(e^{-3Q^2U}\). Crystallographic displacement notation often uses \(B_{\rm iso}=8\pi^2U\), a quantity of dimension length squared unrelated to magnetic induction. With \(Q=4\pi\sin\theta/\lambda\), the amplitude factor can be written \(e^{-B_{\rm iso}\sin^2\theta/\lambda^2}\). Different sources quote the exponent for amplitude or intensity, so determine which observable is being fitted before comparing reported displacement parameters.
Derive the thermal motion of one harmonic mode
For a one-dimensional harmonic displacement of mass \(M\) and angular frequency \(\omega\), quantisation gives
In a number state the terms \(a^2\) and \((a^\dagger)^2\) have zero expectation, while \(aa^\dagger+a^\dagger a=2n+1\). Thermal averaging with \(\bar n=(e^{\hbar\omega/k_BT}-1)^{-1}\) yields
At low temperature the mode retains a zero-point contribution independent of temperature. At high temperature \(\coth x\simeq1/x\) gives \(k_BT/(M\omega^2)\), the equipartition result for the quadratic potential. Light atoms and soft modes can therefore show substantial positional fluctuations. A real crystal contains modes with different polarisations, frequencies and atomic amplitudes; a single fitted Einstein frequency is a model of their weighted contribution, not automatically the frequency of one identifiable phonon.
For illustrative \(M=40\) atomic mass units and ordinary frequency \(f=5.0\,{\rm THz}\), \(\hbar\omega/k_B\) is about \(240\,{\rm K}\). The one-mode zero-point variance is about \(2.53\times10^{-23}\,{\rm m^2}=0.00253\,{\rm \mathring A^2}\). At \(300\,{\rm K}\) the multiplier \(\coth(0.40)\) is about \(2.63\), so the rms displacement grows from \(0.0503\,{\rm \mathring A}\) to \(0.0816\,{\rm \mathring A}\). At \(Q=8.0\,{\rm \mathring A^{-1}}\) the corresponding intensity factors are about \(0.850\) and \(0.654\). Atomic motion still much smaller than an interatomic spacing can therefore noticeably attenuate a high-angle peak.
Infer a covariance change and interpret missing intensity
For the same reflection at two temperatures, after scale, form factor, absorption, structural order and other changes have been corrected,
In an isotropic crystal plot this logarithm against \(Q^2\). The slope estimates negative \(\Delta U\); a nonzero intercept can indicate a relative monitor or normalisation change. With \(I_2/I_1=0.80\) at \(Q=6.0\,{\rm \mathring A^{-1}}\),
This determines a variance difference, not the rms at either temperature individually. Simply taking the square root of a variance difference and calling it the rms increase generally gives the wrong quantity.
For anisotropic fluctuations the measurement probes a quadratic form. Reflections along three crystallographic axes constrain the diagonal elements, while an off-axis vector also depends on cross terms such as \(2Q_xQ_yU_{xy}\). A full covariance must be positive semidefinite. A refinement returning a negative directional variance may indicate insufficient angular coverage, a wrong model or strongly correlated fitting parameters. Symmetry of site occupation can reduce the number of independent covariance components; an analysis with more unconstrained parameters than informative reflections risks interpreting noise as a preferred vibration axis.
Diffuse scattering clarifies what has happened to the lost coherent intensity. For a given configuration the measured intensity is the squared sum of amplitudes. Its thermal expectation can be split into the squared mean amplitude plus the variance of fluctuations about that mean. Correlated displacements between atoms contribute structured diffuse intensity, especially near Bragg positions. An instrument integrating a wide region around a peak can inadvertently include temperature-dependent diffuse background and underestimate the attenuation of the coherent peak. Energy-resolved scattering can separate elastic peaks from inelastic phonon scattering more directly than a simple static intensity ratio.
Reconstruct an off-axis displacement correlation
Suppose calibrated temperature-difference measurements in an orthogonal \(x,y\) plane give
Along a direction halfway between the axes the inferred projection variance is \(0.0075\,{\rm \mathring A^2}\). For \(\hat n=(1,1)/\sqrt2\), the directional variance is \((\Delta U_{xx}+\Delta U_{yy})/2+\Delta U_{xy}\). Thus the cross covariance is \(+0.0015\,{\rm \mathring A^2}\). The direction \((1,-1)/\sqrt2\) should give \(0.0045\,{\rm \mathring A^2}\). A scan of both diagonals cancels the trace term in their difference and isolates twice the off-diagonal covariance directly.
At \(Q=8\,{\rm \mathring A^{-1}}\) these two diagonal directions predict hot-to-cold ratios \(e^{-64(0.0075)}=0.619\) and \(e^{-64(0.0045)}=0.750\). An isotropic fit to their average would conceal this significant angular difference. If only one orientation is measurable due to sample mounting, symmetry constraints or a second mounting angle can supply missing information. The two eigenvalues of the illustrative covariance difference are \(0.0035\) and \(0.0085\,{\rm \mathring A^2}\), both positive. In general the absolute covariance at every temperature must be positive semidefinite, while a difference of two positive covariances need not be positive along every axis. A structural change on heating can reduce fluctuations along one direction while increasing them along another.
Compare a temperature difference with an absolute structure refinement
An unknown constant site displacement and an unknown absolute intensity scale make a single-temperature fit less direct than a temperature ratio. On heating, measure both a small-\(Q\) reflection and a high-\(Q\) reflection in rapid alternation with a fixed incident monitor. Slow detector gain variation then affects the two less differently. If both corrected ratios fall equally, a scale change is more plausible than an added Gaussian displacement factor, which predicts a stronger effect at larger \(Q^2\). Repeating over several independent directions tests that conclusion against anisotropic motion.
Tutorial on a temperature scan
Two equivalent high-symmetry reflections have \(Q=4\) and \(8\,{\rm \mathring A^{-1}}\). Their corrected hot-to-cold ratios are \(0.92\) and \(0.72\). Are these consistent with a common isotropic variance change?
Work through the solution
Individually they give
The close results are consistent within modest intensity uncertainties. Agreement across two points does not establish isotropy in all directions; add noncollinear reflections and check the fitted scale offset.
A fit reports an rms displacement of \(0.10\,{\rm \mathring A}\) along each of three independent axes. What is the expected coherent intensity fraction at \(Q=10\,{\rm \mathring A^{-1}}\), and what is the total rms distance from the mean site?
Work through the solution
Each directional variance is \(0.010\,{\rm \mathring A^2}\). The fraction is
The rms length of the three-dimensional displacement vector is
The projection onto the scattering vector uses one directional variance, while total rms length sums all three.
An isotropic displacement fit stays large at the lowest measured temperature. What measurements distinguish static disorder from zero-point motion?
Work through the solution
A constant displacement contribution can arise from both an unresolved distribution of mean site positions and quantum fluctuations. Extend the temperature range, compare isotopes or mode frequencies where feasible, and measure diffuse scattering with energy resolution. A harmonic calculation with independently measured phonon frequencies predicts a zero-point scale. Absolute Bragg attenuation alone gives a distribution width without uniquely identifying its microscopic source.
Compare the dynamics of a polar lattice mode with a static displacement measurement.