From first principles
Derive the pendulum period and identify the small-angle assumption
A point mass \(m\) suspended on a massless rigid link of length \(\ell\) feels a gravitational torque \(-mg\ell\sin\theta\) about the hinge. Assume a stationary pivot and negligible drag. Angular momentum balance gives an exact nonlinear equation. Replacing \(\sin\theta\) by \(\theta\) only for small angles in radians gives a linear oscillator and its predicted period.
To track finite amplitude, release from rest at angle \(A<\pi\) and use mechanical energy conservation. At any intermediate angle, loss of potential energy equals gained rotational kinetic energy.
The factor four uses the symmetry of the four quarter cycles. The mass cancels even at large amplitude. The exact restoring torque grows more slowly with deflection than its small-angle approximation, so finite-amplitude swings take longer. Measured variation of period with release angle directly tests the linearisation.
Derivation and applications
Derive the period of an oscillator with purely cubic stiffness
A spring with almost no linear stiffness near equilibrium can have a period set primarily by release amplitude. Consider mass \(m\) on a horizontal guide with restoring force \(-\beta x^3\) for \(\beta>0\). Ignore damping and assume the fitted force law holds between \(-A\) and \(+A\). Release from rest at \(x=A\). Integrating the force law gives a quartic potential, and conservation of energy provides the speed anywhere on the inward leg.
By symmetry the time from an extreme position to the centre is one quarter of a full cycle. Write \(dt=|dx|/|\dot x|\) and substitute \(u=x/A\) in the integral. This isolates the amplitude dependence without guessing a sinusoidal shape.
The dimensionless integral evaluates numerically to 1.31103. Its endpoint singularity is integrable because the speed near the turning point vanishes as the square root of the distance remaining. The resulting period and angular frequency are
The positive cubic restores the mass for displacements of either sign, but its tangent stiffness at zero is zero. The full nonlinear dynamics therefore predicts a period diverging with decreasing amplitude. Even a weak residual linear spring would eventually dominate in that limit.
Worked example
Predict the timing of two releases
Take \(m=0.500\) kg, \(\beta=2.00\times10^5\) N/m³ and \(A=20.0\) mm. The predicted period is
Reducing the release to 10.0 mm doubles the predicted period to 1.17 s. At the larger amplitude the centre-crossing speed is
Change the inputs and inspect this calculation below
Second application
Infer stiffness from a measured period
A second fixture of mass 0.800 kg completes a cycle in 0.750 s after release at 15.0 mm. The implied coefficient is \(\beta=m[7.4163/(AT)]^2=3.48\times10^5\) N/m³. Its predicted restoring-force magnitude at release is
An independent static force measurement there tests the dynamic estimate without assuming a sinusoidal motion.
Interactive calculation · Change the inputs of this example
Use the adjustable quantities to test the two worked calculations above. The plot recomputes this derivation’s balance or constitutive relation; its numerical readout reports the quantities needed for the forward calculation and the inverse or design question. Keep the fixed assumptions stated in the readout when comparing with the example values.
Retain the actual restoring moment
A pendulum gives a practical test of a linear model because its length and release angle are easy to set while its period can be measured over many cycles. Approximate the moving body first by a point mass \(m\) at distance \(l\) from a frictionless pivot. With \(\theta\) measured from vertically downwards, gravity produces torque \(-mgl\sin\theta\). Dividing the rotational balance by \(ml^2\) leaves \(\ddot\theta+(g/l)\sin\theta=0\). The linear small-angle frequency \(\omega_0=\sqrt{g/l}\) follows only after replacing \(\sin\theta\) by \(\theta\) in radians.
The leading correction has a definite sign:
At a large positive angle the restoring force magnitude is smaller than the linear extrapolation. The pendulum should take longer to complete its swing. A sign test like this is useful before calculating a period correction.
Derive an integral valid at finite amplitude
For release from rest at amplitude \(A<\pi\), conservation of mechanical energy gives
During one quarter of the orbit the angle travels between zero and \(A\). Substitute \(\sin(\theta/2)=\sin(A/2)\sin\psi\) into the time integral. Cancelling common square roots gives
For modest amplitudes expand the integrand as \(1+\tfrac12 k^2\sin^2\psi+\cdots\). The average of \(\sin^2\psi\) over the quarter interval is one half. Therefore \(T/T_0\simeq1+k^2/4\simeq1+A^2/16\) through second order in amplitude. The oscillation period depends on energy, while in the linear spring model all amplitudes share the same period.
Estimate a measurable timing error
Take \(l=0.80\,\mathrm m\), \(g=9.81\,\mathrm{m/s^2}\) and release at \(A=30^\circ=0.5236\,\mathrm{rad}\). The small-angle period is
The leading correction is 1.71%, giving about 1.825 s. Over ten full oscillations the predicted delay relative to the small-angle model is roughly 0.31 s. Reducing the release angle to 15° reduces the leading relative correction by a factor of four.
A timing series from a damped experimental pendulum may show the period drifting towards \(T_0\) as its amplitude decays. Measuring only the first release angle while averaging many later periods mixes different amplitudes. To test the finite-amplitude law, use consecutive same-direction crossings to measure each local period and estimate its associated amplitude from neighbouring turning points. The correction above is an expansion around zero amplitude. As \(A\) approaches the inverted equilibrium, the exact integral grows without bound and a low-order polynomial is no longer an adequate approximation.
Check the scale of the neglected term
Retaining one further term in the integrand gives \(1+\tfrac12 k^2\sin^2\psi+\tfrac38 k^4\sin^4\psi\). The quarter-interval average of the fourth power of sine is \(3/8\), so \(T/T_0\simeq1+k^2/4+9k^4/64\). At 30° this gives 1.01738, while the leading expansion in amplitude gave 1.01713. The small difference is measurable only if the uncertainty in pendulum length, release angle and crossing times supports the comparison.
Derive an amplitude-dependent resonance relation
A pendulum softens as its amplitude grows because the sine restoring law rises more slowly than its linear tangent. A mechanical flexure can instead harden through geometry. A simple modal model is \(m\ddot x+c\dot x+kx+\beta x^3=F\cos\omega t\). For positive \(\beta\) the restoring stiffness increases with excursion. Assume one dominant harmonic and take \(x\approx A\cos(\omega t-\phi)\). Expanding the cubic gives
Keeping only the fundamental turns the cubic term into an amplitude-dependent in-phase force.
Balance in-phase and quadrature components against the input, square and add to eliminate \(\phi\). The first-harmonic amplitude estimate satisfies
In a lightly damped free motion the same approximation gives a backbone frequency \(\omega_b^2\approx[k+(3/4)\beta A^2]/m\). This is an amplitude-dependent estimate of conservative oscillation frequency, not a new eigenvalue of the linearised equilibrium. At very small amplitude it recovers \(\sqrt{k/m}\), while a negative cubic coefficient tilts the relation towards lower frequencies. If the cubic approximation is only a local expansion, do not extrapolate it until it predicts an unphysical loss of global stiffness.
Identify a hardening spring from two release amplitudes
A test component has moving mass 1.0 kg and small-amplitude stiffness 400 N/m. Low-level ring-down gives \(\omega_0=20\,\mathrm{rad/s}\). At measured oscillation amplitude 20 mm the dominant free frequency is approximately 22 rad/s. Under the weakly nonlinear one-harmonic model, \(\beta\simeq4m(22^2-20^2)/[3(0.020)^2]=2.80\times10^5\,\mathrm{N/m^3}\). At 10 mm the inferred backbone is \(\sqrt{400+0.75(2.8\times10^5)(0.010)^2}=20.52\,\mathrm{rad/s}\), a direct third reading against which to test the fit.
Now drive near 22 rad/s with viscous coefficient \(c=0.80\,\mathrm{N\,s/m}\). At the 20 mm backbone amplitude the spring and inertia fundamentals cancel, so maintaining this motion takes forcing \(F=c\omega A=0.352\,\mathrm N\) in quadrature with displacement. The neglected cubic third-harmonic force amplitude is
its displacement effect can nevertheless be small because the oscillator is driven far from its fundamental resonance at 66 rad/s. A separate mode near that frequency would invalidate this simplification. In a forced frequency sweep the amplitude equation can admit several positive roots near resonance. Its algebra does not establish their stability; slow upward and downward sweeps, each with sufficient settling time, can reveal different stable responses and jump transitions.
An initial static measurement tests the sign of the fitted coefficient independently. At a displacement of 20 mm the linear restoring force is
the cubic contribution is
The predicted static force is therefore 10.24 N, and the tangent stiffness is
This tangent stiffness applies to small vibrations around a held biased equilibrium. Using it directly for an oscillation centred at zero would overestimate the measured amplitude-dependent frequency because the instantaneous stiffness changes during each cycle. Static bias and free oscillation amplitude are physically different tests of the same nonlinear restoring law.
Repeating a decay test around a deliberately shifted equilibrium distinguishes the two experimentally.
Set an amplitude limit for a pendulum-based timing model
For a rigid pendulum released from rest the exact period ratio is \(2K(\sin^2(\theta_0/2))/\pi\), where the complete elliptic integral here uses its parameter rather than its modulus. Compare it with the first amplitude correction \(1+\theta_0^2/16\), with angle in radians.

Read values from the plot
| Release amplitude (degrees) | Exact energy integral | Leading expansion |
|---|---|---|
| 0 | 1 | 1 |
| 37.5 | 1.0274 | 1.0268 |
| 75 | 1.119 | 1.1071 |
| 112.5 | 1.3132 | 1.241 |
| 150 | 1.7622 | 1.4284 |
Interactive calculation · change the inputs of this example
Increase the maximum release angle and compare the energy integral with the first series correction. Changing length rescales both periods.
The curves below are recalculated from this section’s equations in your browser. The fixed reference plot above remains available for comparison.