Fundamentals / Mechanical engineering / Machine dynamics

Modal selectivity and finite amplitude

Determine whether a force excites a mode and relate an oscillator’s amplitude to the accuracy of a period measurement.

Excite an antisymmetric mode

Two masses of 1.5 kg have symmetric and antisymmetric mode shapes (1,1) and (1,−1) at natural frequencies 12 and 18 rad/s. Apply harmonic forces (+6,−6) N at 6 rad/s. Find both modal amplitudes and the physical displacement amplitudes with their relative phase.

Reveal the worked solution

Both modal masses are 3 kg. The symmetric projection is zero, and the antisymmetric projection is 12 N. Hence its amplitude is

\[12/[3(18^2-6^2)]=0.01389\,\mathrm m.\]

The physical amplitudes are +13.89 and −13.89 mm in a common phase convention. The cancellation of the symmetric force projection determines the response symmetry.

Set a working stroke

An auxiliary mass moves against a spring attached to a primary machine. An undamped absorber must cancel an 18 N harmonic force at 25 Hz while its own amplitude stays at or below 1.5 mm. Find minimum spring stiffness and corresponding tuned mass. Does tuning ensure a small response at all speeds?

Reveal the worked solution

At exact cancellation \(X_p=0\) and \(|X_a|=F/k_a\). Thus

\[k_a\ge18/0.0015=12000\,\mathrm{N/m}.\]

At the limiting stiffness the tuned mass is

\[12000/(2\pi25)^2=0.486\,\mathrm{kg}.\]

The coupled modes give resonances away from the cancellation frequency. A varying-speed drive can cross these frequencies.

Estimate a release-angle limit

A pendulum experiment tolerates an amplitude-dependent period change of 0.5%. Use the leading finite-amplitude correction to estimate its largest release angle. For a 1.0 m pendulum released at half that angle, estimate the accumulated timing shift over 40 cycles.

Reveal the worked solution

The leading fraction is \(A^2/16\). Setting it to 0.005 gives

\[A=0.2828\,\mathrm{rad}=16.2^\circ.\]

Halving the angle reduces the leading correction to 0.00125. The small-angle period is 2.006 s, giving \(40(2.006)(0.00125)=0.100\,\mathrm s\) delay. Precision beyond the retained order would require a higher-order term or the exact integral.

Specify an isolation mount from two measurements

A 40.0 kg instrument is mounted on springs. Free-vibration peaks of the same sign are 8.0 and 4.0 mm four periods apart. The four periods take 1.60 s. Estimate the equivalent stiffness and damping. A bench beneath the instrument moves sinusoidally at 10 Hz with 0.50 mm amplitude. Predict absolute instrument motion and relative mount travel.

Worked solution

The logarithmic decrement per period is ln(2)/4 = 0.1733 and the damping ratio is δ/√(4π²+δ²) = 0.0276. The damped period is 0.40 s, giving ωd = 15.71 rad/s. The undamped frequency ωn = ωd/√(1−ζ²) is 15.71 rad/s to the displayed precision. The equivalent k = mωn² ≈ 9.88 kN/m and c = 2ζmωn ≈ 34.7 N s/m.

At r = ω/ωn ≈ 4.00 the absolute-motion transmissibility is √[1+(2ζr)²]/√[(1−r²)²+(2ζr)²] ≈ 0.0683. The instrument thus moves about 0.034 mm. The base-relative displacement amplitude instead uses r² in the numerator and is about 1.067 times the input, or 0.533 mm.

These two answers size different things. The instrument sees the small absolute vibration while the spring must accommodate roughly the bench excursion. Near resonance the measured low damping would permit much larger travel; a mount chosen only from the 10 Hz test could bottom during startup. The single-mode fit also assumes the measured peaks lie within a linear range.