Place a fast loop where the disturbance enters
Use the small-signal motor equations \(L\dot i+Ri=v-k_e\omega\), \(J\dot\omega+B\omega=k_t i-\tau_L\), and \(\dot\theta=\omega\). Measure current at the converter and motion at the shaft. A speed loop alone leaves rapid electrical disturbances to propagate before they appear in shaft motion. Close a fast local current loop and send it a current reference from the mechanical loop. Treat back EMF as a disturbance or add measured-speed feedforward.
Choose \(C_i(s)=k_{pi}+k_{ii}/s\) with \(k_{ii}/k_{pi}=R/L\). For the nominal \(1/(Ls+R)\) current plant the open loop reduces to \(k_{pi}/(Ls)\) and the closed transfer is \(\omega_i/(s+\omega_i)\), with \(k_{pi}=L\omega_i\) and \(k_{ii}=R\omega_i\). At \(L=0.010\) H, \(R=1\) ohm and \(\omega_i=1000\) rad/s the gains are 10 V/A and 1000 V/(A s). The approximation presupposes adequate measurement, switching and computation bandwidth.
Choose the middle loop against an inner-loop error budget
If current follows its command over the speed-loop band, the torque-to-speed plant is \(k_t/(Js+B)\). A speed PI controller with \(k_{p\omega}=J\omega_v/k_t\) and \(k_{i\omega}=B\omega_v/k_t\) gives an approximate closed speed response \(\omega_v/(s+\omega_v)\). With \(J=0.020\), \(B=0.020\), \(k_t=0.40\) in SI and \(\omega_v=100\) rad/s, the gains are 5 in the corresponding current-per-speed and integral units. The neglected current lag contributes \(\arctan(100/1000)=5.71°\) at that speed-loop crossover. Reserve this phase when validating the full model. A torque disturbance enters the mechanical balance directly and is primarily rejected by this middle loop.
Convert a position requirement into a realizable crossover
Use position proportional feedback \(\omega_{ref}=K(\theta_{ref}-\theta)\), the achieved speed model \(\omega_v/(s+\omega_v)\) and total outer-path delay \(\tau\). In this reduced model the exact position-loop frequency response is \(L(s)=K e^{-s\tau}/[s(1+s/\omega_v)]\). Choosing \(K\) for a desired amplitude crossover separates magnitude tuning from the residual phase budget:
At \(\tau=6\) ms, \(\omega_v=100\) rad/s and required margin 45°, solving the monotone equation gives \(\omega_c\leq51.56\) rad/s. The 50 rad/s design has only 46.25° before any additional sensor or drive lag. At 20 rad/s the nominal margin is 71.81°. The notebook separately evaluates the delay-free closed-loop poles with OneSimulation. Their decay rate and the delayed loop’s phase margin measure different properties.
Interactive experiment · Spend the phase budget with bandwidth and delay sliders
Choose the achieved inner-loop bandwidth, the outer-path delay and the intended outer crossover. The browser adjusts the proportional gain to place the amplitude crossover exactly at that frequency, then evaluates the remaining phase margin. The 45° line is a design target; it is not the boundary of stability itself.
Begin at an inner bandwidth of 100 rad/s, delay 6 ms and crossover 50 rad/s. Double the delay and observe the lost 17.19°. Then lower the requested crossover until the target is recovered. The zero-delay pole margin in the readout is computed from the quadratic closed-loop characteristic polynomial. Compare it with the OneSimulation stability diagnostic in the notebook; it does not certify the delayed system.
Continue in the OneSimulation notebook · Download its Python model
OneSimulation experiment · An achieved inner speed bandwidth and transport delay bound the outer-loop crossover
Run the notebook with OneSimulation 0.2.0, NumPy, SciPy and Matplotlib. Change the input data and compare your run with the recorded result.
"""Evaluate inner-lag and transport-delay limits on an outer position loop."""
import numpy as np
import matplotlib.pyplot as plt
from onesim.physics.systems.control import stability_margin
inner_pole = 100.0 # rad/s, achieved bandwidth of the closed speed loop
def outer_gain(crossover):
return crossover*np.sqrt(1+(crossover/inner_pole)**2)
def phase_margin(crossover, delay):
return 90-np.rad2deg(np.arctan(crossover/inner_pole)+crossover*delay)
frequencies = np.linspace(1,90,250)
fig, ax = plt.subplots(figsize=(6.4,3.7), layout="constrained")
for delay in [0.0,0.006,0.012]:
ax.plot(frequencies, phase_margin(frequencies,delay),label=f"{1000*delay:.0f} ms delay")
for crossover in [20.0, 50.0]:
gain = outer_gain(crossover)
poles = np.roots([1.0,inner_pole,inner_pole*gain])
print(f"crossover {crossover:.0f} rad/s: delay-free pole margin = "
f"{stability_margin(poles,discrete=False):.3f} /s, "
f"6 ms phase margin = {phase_margin(crossover,0.006):.2f} deg")
ax.axhline(45,color="0.4",ls=":",label="45° requirement")
ax.set(xlabel="Outer gain crossover (rad/s)",ylabel="Phase margin (degrees)")
ax.legend()
plt.show()Reference run
crossover 20 rad/s: delay-free pole margin = 28.543 /s, 6 ms phase margin = 71.81 deg crossover 50 rad/s: delay-free pole margin = 50.000 /s, 6 ms phase margin = 46.25 deg

Inspect failure signatures from the inside out
Measure the current-reference response with the mechanical loop open in the model. Then close speed feedback and compare measured torque-step recovery with the linear prediction. Finally apply a position command and log reference and achieved current, shaft speed and position together. Under voltage clipping the actual current cannot track its command at speed. A speed integrator that keeps charging can dominate the later position excursion. Use actuator feedback for anti-windup and check the actual limits at the operating speed.
Which loop receives the position sample delay?
A rotor-position timestamp used to derive speed can delay both mechanical loops. A transport delay introduced only between the supervisory controller and the drive delays the outer loop. Draw the measurement paths before inserting a single lumped delay or counting it twice.
Exercises on a changed architecture
Keep crossover at 50 rad/s while total delay rises from 6 to 12 ms. What does this do to the reduced-model margin?
Worked solution
The gain is unchanged by pure delay. The added lag is \(50(0.006)=0.30\) rad, or 17.19°. Margin falls from 46.25° to 29.06°, below the target.
At high speed the current sensor follows its local model but digital speed estimates have 4 ms of additional filtering delay. Where should the new uncertainty enter?
Worked solution
Place it in the speed measurement path. Recompute the middle-loop closed dynamics before using them as the position plant. Adding it only to the outer-loop delay would miss loss of speed-loop robustness.
Further reading · Åström and Murray, Feedback Systems, 2nd ed., Chapters 10–11 and 15.