Fundamentals / Physics / Electrodynamics / Electrostatic field theory and measurement

Capacitance matrices, floating nodes and controlled approximation bounds

A multi-electrode device generally has no single capacitance until the other terminals have been connected or isolated. An energy identity determines the matrix that relates voltages to charges, and a complementary flux identity can certify estimates even when the exact field is unknown.

Build the matrix from unit-voltage experiments

Consider \(n\) isolated conductor surfaces embedded in a connected linear dielectric, plus a grounded reference conductor or decay relative to a reference at infinity. There is no free charge in the dielectric. Define the weighting function \(w_j(\mathbf x)\) by putting conductor \(j\) at 1 V, all other conductors and the reference at zero, then dividing by 1 V. For arbitrary voltages \(V_j\), linearity and uniqueness give

\[\phi(\mathbf x)=\sum_jV_j w_j(\mathbf x).\]

The charge on conductor \(i\) is an integral of displacement leaving its metal into the dielectric. Using a normal \(\mathbf n\) pointing out of the dielectric into the metal gives

\[Q_i=\int_{S_i}\epsilon\partial_n\phi\,dA.\]

Therefore

\[Q_i=\sum_j C_{ij}V_j,\]
\[C_{ij}=\int_{S_i}\epsilon\,\partial_n w_j\,dA=\int_\Omega\nabla w_i\cdot\epsilon\nabla w_j\,dV .\]

The last equality follows by multiplying the charge-free field equation for \(w_j\) by \(w_i\) and integrating by parts. The boundary integral selects just conductor \(i\) because its weighting function is unity there and zero on every other conductor. The volume expression proves reciprocity \(C_{ij}=C_{ji}\) for a symmetric dielectric tensor. The diagonal terms are positive, since they integrate the squared fields of each independent one-volt experiment. In an ordinary connected isotropic configuration a positive voltage on \(j\) with \(i\ne j\) grounded puts negative induced charge on \(i\); the corresponding mutual coefficient \(C_{ij}\) is nonpositive.

The stored energy is

\[U=\tfrac12\sum_{ij}V_i C_{ij}V_j.\]

Positive material response makes the reduced matrix with an effective reference positive definite under usual connected boundary conditions. If all conductors including the external closing conductor are retained without fixing a reference, changing all voltages by a common constant produces no field. The full matrix then has a zero common-voltage mode and each row sums to zero. Removing the grounded reference from the matrix removes this gauge null direction; its remaining rows need not sum to zero. Treating both statements as universal would create a spurious constraint on measured terminal data.

Convert a field matrix to a circuit measurement

A two-port device might have reduced matrix in picofarads \(C=\begin{pmatrix}12&-3\\-3&8\end{pmatrix}\) relative to its grounded enclosure. With conductor 1 at 2 V and conductor 2 at 0 V, charges are \(24\) pC and \(-6\) pC. The grounded enclosure takes the compensating \(-18\) pC. Reciprocity predicts that holding conductor 1 at 0 V and conductor 2 at 2 V puts \(-6\) pC on conductor 1. The diagonal 12 pF includes both the coupling to conductor 2 and the path to the enclosure. In an equivalent lumped model the positive pair capacitance between 1 and 2 is 3 pF, while the two separate couplings to ground are 9 and 5 pF. The sign of a Maxwell matrix off-diagonal is opposite to a positive capacitor drawn between two nodes.

Now disconnect conductor 2 after neutralising it. Its total charge stays zero while its voltage becomes an unknown. The second matrix row demands \(-3V_1+8V_2=0\). Thus \(V_2=3V_1/8\), giving apparent capacitance seen at terminal 1 equal to \(12-9/8=10.875\) pF. Grounding conductor 2 would instead yield 12 pF. The change is a measurable effect of the prepared state, not a change in the dielectric constant of the material. If conductor 2 already carries charge \(Q_2^0\), its voltage acquires a constant offset \(Q_2^0/C_{22}\) in addition to the response to \(V_1\).

For several floating nodes write their block equation as \(Q_f=C_{fa}V_a+C_{ff}V_f\). If the reference fixes the potential freedom, solve \(V_f=C_{ff}^{-1}(Q_f-C_{fa}V_a)\) and substitute into the active-node block. The differential active capacitance is the Schur complement \(C_{aa}-C_{af}C_{ff}^{-1}C_{fa}\). It is symmetric and positive for a positive full reduced matrix. With fixed floating charges the constant term shifts active charges but leaves this differential matrix unchanged in a linear medium. An actual cable measurement that results from leaving a neighbouring shield unconnected should be compared to this elimination, not to the original diagonal.

Obtain an upper capacitance bound by trying a voltage

For a two-terminal charge-free dielectric at prescribed voltage difference \(V\), every admissible continuous trial potential satisfying the electrode voltages gives an energy at least as large as the exact electrostatic energy. This follows by writing the trial as exact plus a perturbation vanishing on fixed-voltage electrodes and expanding the energy. The mixed term integrates to zero because the exact displacement is divergence free. If exterior walls are insulated, the exact normal displacement vanishes there and the trial need not be assigned a fixed potential on them. Thus \(C\le 2U_{\rm trial}/V^2\). The fields must genuinely arise as a gradient of one trial voltage. Guessing unrelated components of an electric field does not provide this upper bound.

For a capacitor of plate area \(A\), separation \(d\), and scalar permittivity varying in the gap, choose a linear voltage along the plate normal. The trial energy gives

\[C/A\leq \langle\epsilon\rangle/d,\]

where the average is over the gap volume divided by \(Ad\). For dielectric columns that run parallel to the applied field with no change of material along the field direction, the linear potential can be exact. For layers stacked normal to the field it usually overestimates capacitance. The same arithmetic average thus serves as the actual result or a strict upper bound depending on geometry, even when the material fractions are identical.

A complementary trial with a divergence-free displacement

Fix total plate charges \(\pm Q\) instead, taking no volume free charge. An admissible displacement trial must have the prescribed flux into each electrode, no flux through insulating side walls, continuous normal component across free-charge-free interfaces, and zero divergence inside. It need not correspond to an exact potential-gradient electric field. Consider \(U_D[\mathbf D]=\tfrac12\int\mathbf D\cdot\epsilon^{-1}\mathbf D\,dV\). Write a trial as \(\mathbf D_*+\delta\mathbf D\). The cross term is \(\int(-\nabla \phi_*)\cdot\delta\mathbf D\,dV=0\): integration by parts gives zero bulk divergence and each conductor has constant voltage multiplying zero net flux change. Thus \(U_D\ge Q^2/(2C)\) and

\[\frac{Q^2}{2U_D^{\rm trial}}\ \le C\le\ \frac{2U_V^{\rm trial}}{V^2}.\]

Unlike two competing estimates, these inequalities identify which side contains the exact answer. For the same parallel-plate geometry choose constant displacement \(D_z=Q/A\). It yields \(C/A\geq1/[d\langle1/\epsilon\rangle]\), the harmonic-mean lower bound. For layers stacked normal to the plates that trial is exact. For columns parallel to the field the upper bound is exact. An arbitrarily shaped two-phase composite satisfies both under the stated plate and insulating-side conditions. This gives a strong physical check before solving detailed microstructure on a mesh.

Use measured numbers to rule out a material model

Take equal volume fractions of relative permittivities 2 and 8 in a cell of area \(100\) mm² and thickness 1.0 mm. The harmonic mean is 3.2, arithmetic mean 5.0. Since \(\epsilon_0A/d=0.8854\) pF, the admissible capacitance interval is 2.83–4.43 pF. A measured 3.3 pF is consistent with many internal geometries and does not determine how the two materials are arranged. A calibrated value of 5.2 pF would require examining fringing, area and thickness, parallel cable capacitance, dispersive or conducting response, and the assumed constituent data. Merely refining an interior mesh cannot produce a static value outside the proven interval if it faithfully solves the same ideal model.

For a field computation use the matrix reciprocity relation as one diagnostic and the two variational bounds as another. An electrostatic finite-element potential may produce a reliable energy estimate while numerical differentiation at a sharp electrode edge produces poor charge density. Integrating boundary fluxes gives each terminal charge, but reconstructing \(C_{ij}\) by the mixed energy integral often has a different error sensitivity. Comparing both over a grid sequence can indicate whether the error is concentrated at edges or in the field volume. Symmetrising a noisy measured matrix by averaging its transpose removes an antisymmetric discrepancy but cannot establish positivity or explain an inaccurate common scale.

Construct a complete measurable matrix without numerical differentiation

Three thin spherical conductors have radii \(a<b<c\). The outer one is tied to the reference potential. Homogeneous material of permittivity \(\epsilon_1\) fills the inner annulus \(a<r<b\) and another material \(\epsilon_2\) fills \(b<r<c\). Spherical symmetry gives each annulus its own independent radial displacement field fixed by its electrode voltage difference. Define the ordinary two-sphere gap capacitances \(K_1=4\pi\epsilon_1 ab/(b-a)\),

\[K_2=4\pi\epsilon_2 bc/(c-b).\]

The inner conductor takes \(K_1(V_1-V_2)\). The middle one has two faces, carrying the opposite inner gap charge and an outer gap charge \(K_2V_2\). Thus \(Q_1=K_1V_1-K_1V_2\) and \(Q_2=-K_1V_1+(K_1+K_2)V_2\). Every sign and every term can be read from a physical face.

In vacuum choose \(a=10\) mm, \(b=20\) mm, \(c=40\) mm. Then \(K_1=2.225\) pF and \(K_2=4.451\) pF. Driven at 3.0 V with the middle conductor grounded, the inner sphere carries \(6.68\) pC and the outer gap has zero field. With the middle conductor floating and neutral, \(V_2=K_1V_1/(K_1+K_2)=1.0\) V. The inner sphere now carries \(4.45\) pC. The inner and outer faces of the floating sphere carry exactly opposite charges, although the conductor has a nonzero voltage. Integrating a current meter attached to the conductor during charging need not tell you each face's charge separately.

Now electrically connect the inner two conductors. Their common voltage sets the inner field to zero. The combined conductor has capacitance \(K_2\) to the exterior, independent of \(a\). This third preparation is distinct from grounding or floating the middle shell. Before calculating an experimental 'device capacitance', draw the electrical connections as well as the geometric cross section. In a larger matrix a driven conductor and a driven guard at the same voltage should have their charges combined only if the experimental ammeter actually measures their total current.

One can also recover the two constituent permittivities from just two carefully selected scalar measurements. Ground the middle shell to determine \(K_1\) directly. Then float it neutral and measure \(K_{\rm ser}=K_1K_2/(K_1+K_2)\), giving \(K_2=K_{\rm ser}K_1/(K_1-K_{\rm ser})\). If \(K_2\) is very large, the floating and grounded readings nearly coincide and their difference becomes noise sensitive. An alternative is to drive inner and middle together and measure the outer-gap current directly. The algebra selects a better experimental protocol instead of hiding ill-conditioning in a formula.

Tighten a variational bound without solving the entire field

Take the stacked two-layer capacitor with no space charge, equal layer thickness and isotropic permittivities \(\epsilon_1=2\epsilon_0,\epsilon_2=8\epsilon_0\). A single linear trial produces the arithmetic-mean upper bound. Insert one interior voltage degree of freedom at a point that coincides with the material interface. The resulting piecewise-linear trial space contains the exact solution. Minimising its energy makes the normal displacements equal, reproducing the harmonic-mean capacitance exactly. A global quadratic trial with the same number of extra parameters will usually perform worse because its derivative is continuous while the exact normal field jumps.

To see this quantitatively write \(x=z/d\) on the unit interval and \(V(x)=V_0[x+\eta x(1-x)]\), with the lower half at relative permittivity 2 and upper half at 8. This trial fixes both endpoints. Its dimensionless capacitance upper estimate is

\[c(\eta)=\int_0^1\epsilon_r(x)[1+\eta(1-2x)]^2dx.\]

Integrating gives

\[c(\eta)=5-3\eta+(5/3)\eta^2.\]

The best quadratic trial has \(\eta=0.9\) and \(c=3.65\), compared with 5.00 for the straight line and 3.20 for the exact layered solution. The unrefined constant-displacement lower trial already supplies 3.20, so the two-field comparison certifies an interval before any field-map visualisation.

Why did the smooth trial still overestimate by 14%? At its endpoints it predicts slopes 1.9 and 0.1 times the mean field magnitude, whereas the exact field has slopes 1.6 and 0.4 in the two halves. Optimising a volume energy distributes a global smooth approximation across both layers. It has no mechanism to jump at the known interface, so an error persists even with its one coefficient optimised perfectly. The example explains why fitting material interfaces in a mesh, or using basis functions that admit correct normal derivative jumps, can matter more than merely increasing polynomial degree.

In an irregular two-dimensional composite an exactly divergence-free complementary trial can be constructed from a stream function \(\Psi\): take \(\mathbf D=(\partial_y\Psi,-\partial_x\Psi)\) in Cartesian coordinates. Its divergence vanishes identically. Total flux through an oriented path is a difference of \(\Psi\) at its endpoints, so carefully chosen boundary values enforce required electrode charges and zero leakage on insulating sides. Optimising \(\int\mathbf D\cdot\epsilon^{-1}\mathbf D/2\) over such trial functions tightens the lower capacitance bound. Optimising the independent voltage trial tightens the upper one. The difference between their resulting bounds quantifies what the chosen approximation spaces still fail to resolve.

What an AC bridge measures when a nominally floating terminal leaks

A real high-impedance lead is neither perfectly floating nor an ideal ground at every frequency. Add a leakage resistance \(R\) from conductor 2 of the two-port example to its grounded enclosure. Keep the reduced static capacitance matrix \(C\) fixed, linear and quasistatic at the frequencies of interest. Let terminal 1 be driven sinusoidally and terminal 2 have no other external drive. Using \(e^{i\omega t}\) here for circuit phasors, charge continuity at terminal 2 gives

\[i\omega(C_{21}V_1+C_{22}V_2)+V_2/R=0.\]

The outward conductive current plus the rate of charge stored in the electrode must vanish. Solving for the active terminal admittance gives

\[Y_{\rm in}=i\omega C_{11}+\frac{\omega^2 C_{12}C_{21}}{1/R+i\omega C_{22}} .\]

At low frequency the leakage holds terminal 2 close to ground, so the leading measured capacitance is \(C_{11}\). At high frequency the floating condition is recovered and \(Y_{\rm in}/(i\omega)\to C_{11}-C_{12}C_{21}/C_{22}\). The effective admittance also has a positive real part, since the driven voltage on terminal 2 supplies Joule heat in the leakage resistance. This term persists even if the dielectric itself is lossless. An AC capacitance meter reporting a frequency-dependent loss tangent might therefore be detecting a boundary preparation rather than intrinsic material loss.

Take \(C_{22}=8\) pF and \(R=100\) MΩ. The crossover \(1/(2\pi R C_{22})\) is 199 Hz. At this frequency the quadrature capacitance is halfway between 12.0 and 10.875 pF, namely 11.4375 pF. The corresponding loss conductance divided by \(\omega\) is 0.5625 pF. An independent verification uses the port voltage ratio at crossover,

\[|V_2/V_1|=|C_{21}|/(\sqrt2 C_{22})=0.265.\]

Compute dissipated power as \(|V_2|^2/(2R)\) for peak phasor amplitudes and compare it with \(\operatorname{Re}Y_{\rm in}|V_1|^2/2\); the two results must coincide.

The crossover shifts inversely with the leakage resistance while its two limiting capacitances stay fixed in this simple model. Measuring several shunt resistances or adding a known external one provides a direct way to test this interpretation. If a neighbouring shield is connected to a voltage follower instead, its response includes the follower's own gain and phase; static floating-node elimination is insufficient. Extending the field-derived capacitance matrix by experimentally known terminal circuits makes it possible to distinguish changes in electrostatic geometry from changes in what the surrounding measurement wiring enforces.

Close the charge balance at a floating conductor

Compare voltages obtained by fixing a conductor potential and by prescribing its net charge. Check the sign of the off-diagonal capacitance terms.

Tutorial · distinguish a floating port and an inadmissible trial

What changes after disconnecting a biased guard?

Using the 12, 8 and −3 pF coefficients, start with terminal 1 at 0 V and terminal 2 at 1 V. Disconnect terminal 2, then raise terminal 1 to 2 V. Find the new floating voltage, both charges and the change of active charge.

Work through the solution

Initially \(Q_2=8\) pC, which stays fixed. The new condition is \(8=-3(2)+8V_2\), giving \(V_2=1.75\) V. Terminal 1 initially held \(-3\) pC; finally it holds \(12(2)-3(1.75)=18.75\) pC. Its change is 21.75 pC, or \(10.875\) pF times the 2 V increment. This reproduces the neutral-floating differential result but a different absolute charge. A charge amplifier reset at the initial state observes the change, whereas a device measuring absolute node potential distinguishes the stored preparation.

Can a lower voltage-trial estimate be trusted?

A potential approximation for the two-phase cell returns 2.70 pF while a constant-displacement trial gives 2.83 pF. The implementer reports the smaller number because its potential looked smoother. Diagnose the inconsistent pair.

Work through the solution

For admissible fields on the same problem the flux trial gives a lower capacitance bound and the potential trial an upper one. The reversed interval cannot result from arbitrary coarseness alone. Check that the voltage trial satisfies the exact terminal difference and that all physical material volumes and energy factors are included. Check that the displacement trial has the correct area-normalised total charge and satisfies flux continuity. Finally examine numerical quadrature and unit conversion. Comparing the plots of the two fields does not fix an inadmissible constraint. If both are corrected, their gap gives an actual a posteriori uncertainty interval even without an analytic solution.

Further reading